3
IR2104(S) & (PbF)
www.irf.com
Symbol Definition Min. Typ. Max. Units Test Conditions
VIH Logic “1” (HO) & Logic “0” (LO) input voltage 3 — — VCC = 10V to 20V
VIL Logic “0” (HO) & Logic “1” (LO) input voltage — — 0.8 VCC = 10V to 20V
VSD,TH+ SD input positive going threshold 3 — — VCC = 10V to 20V
VSD,TH- SD input negative going threshold — — 0.8 VCC = 10V to 20V
VOH High level output voltage, VBIAS - VO— — 100 IO = 0A
VOL Low level output voltage, VO— — 100 IO = 0A
ILK Offset supply leakage current — — 50 VB = VS = 600V
IQBS Quiescent VBS supply current — 30 55 VIN = 0V or 5V
IQCC Quiescent VCC supply current — 150 270 VIN = 0V or 5V
IIN+ Logic “1” input bias current — 3 1 0 VIN = 5V
IIN- Logic “0” input bias current — — 1 VIN = 0V
VCCUV+ VCC supply undervoltage positive going 8 8.9 9.8
threshold
VCCUV- VCC supply undervoltage negative going 7.4 8.2 9
threshold
IO+ Output high short circuit pulsed current 130 210 — VO = 0V
PW ≤ 10 µs
IO- Output low short circuit pulsed current 270 360 — VO = 15V
PW ≤ 10 µs
Symbol Definition Min. Typ. Max. Units Test Conditions
ton Turn-on propagation delay — 680 820 VS = 0V
toff Turn-off propagation delay — 150 220 VS = 600V
tsd Shutdown propagation delay — 16 0 220
trTurn-on rise time — 100 170
tfTurn-off fall time — 50 90
D T Deadtime, LS turn-off to HS turn-on & 400 520 650
HS turn-on to LS turn-off
Static Electrical Characteristics
VBIAS (VCC, VBS) = 15V and TA = 25°C unless otherwise specified. The VIN, VTH and IIN parameters are referenced to
COM. The VO and IO parameters are referenced to COM and are applicable to the respective output leads: HO or LO.
Dynamic Electrical Characteristics
VBIAS (VCC, VBS) = 15V, CL = 1000 pF and TA = 25°C unless otherwise specified.
V
mV
V
mA
M T Delay matching, HS & LS turn-on/off — — 60
ns
µA