• Both crimp style and insulation displacement
receptacles can be used
• Housing-to-terminal locks
• Mountable on a variety of panels
• Highly reliable housing construction
Specifications –––––––––––––––––––
• Current rating: Crimp style HR connectors type
3A AC, DC max.
Insulation displacement HR connectors type
2A AC, DC max.
• Voltage rating: 250V AC, DC max. (See Note below.)
• Temperature range: -25˚C to +85˚C
(including temperature rise in applying
electrical current)
• Contact resistance: Initial value/10m Ωmax.
After environmental testing/20m Ωmax.
• Insulation resistance: 500M Ωmin.
• Withstanding voltage: 1,000V AC/minute
• Applicable wire: AWG #26 to #22
0.13 to 0.33mm2
• Applicable panel thickness: 0.8 to 1.6mm
Note: Contacts are exposed at the housing lances.
Care should be taken so that these parts do not touch the
metal section of the chasis.
of Product information page).
Note: 1. Punch holes in the panel according to the sketch and table shown above. Burrs must be removed.
2. The strength of the panel must be considered when punching two or more holes.
3. The connector must be inserted from the same side as the hole is punched.
Panel layout and Assembly layout