www.DataSheet.co.kr ABC400-10XXG Data Sheet Features * * * * * * * * * High efficiency up to 91% at 230VAC Universal AC input voltage range: 90-264 VAC Active power factor correction Over temperature, output overvoltage, overcurrent and short circuit protection Low conducted and radiated EMI (EN 55022 cl A) Safety approval to UL/CSA/EN/IEC60950-1 High power density design: 16 W/in3 Compact size: 3.0 (W) x 1.5 (H) x 5.0 (L) inches ROHS-compliant Applications * Telecom, datacom, industrial equipment. Description This is a compact and efficient series of AC-DC power supplies suited for telecom, datacom and many other applications. this family meets the international information technology safety standards with the CE-Mark for the European Low Voltage Directive (LVD). their high efficiency allows a very minimal power loss in end equipment, resulting in higher reliability, ease of thermal management and regulatory approvals for an environmentally friendly end product. Content 1 ORDERING INFORMATION............................................. 2 2 OVERVIEW ....................................................................... 2 3 ABSOLUTE MAXIMUM RATINGS ................................... 3 4 ENVIRONMENTAL AND MECHANICAL ......................... 3 5 INPUT SPECIFICATIONS ................................................ 3 5.1 INPUT FUSE ............................................................ 4 5.2 INRUSH CURRENT ................................................. 4 5.3 INPUT UNDER-VOLTAGE ....................................... 4 5.4 POWER FACTOR CORRECTION ........................... 4 5.5 EFFICIENCY ............................................................ 4 6 OUTPUT SPECIFICATIONS ............................................ 5 7 PROTECTION................................................................... 8 Rev. AA, 19-May-2011 PRELIMINARY 7.1 OVERVOLTAGE PROTECTION ..............................8 7.2 CURRENT LIMITATION ...........................................8 8 POWER GOOD SIGNAL ..................................................9 9 ELECTROMAGNETIC COMPATIBILITY .........................9 9.1 IMMUNITY ................................................................9 9.2 EMISSION ..............................................................10 10 SAFETY / APPROVALS ...............................................10 11 MECHANICAL ..............................................................10 11.1 DIMENSIONS .......................................................11 11.2 CONNECTIONS ...................................................13 Page 1 / 13 www.power-one.com Datasheet pdf - http://www.DataSheet4U.net/ www.DataSheet.co.kr ABC400-10XXG Data Sheet 1 ORDERING INFORMATION Product Family Output Power Dash # Outputs ABC400-10XX 400W - 1 Standard: 0 S-Type: 1-9 0 Vo-Voltage 12VDC / 24VDC / 48VDC RoHS compliant G 2 OVERVIEW The ABC400-10XXG is a high efficiency and high power density AC to DC power supply. It incorporates interleaved transition mode PFC converter and well proven two-FET forward converter, providing increased system reliability and high efficiency. with around 1m/s system air cooling, ABC400-1012G can delivery up to 360W continuous output power and 408W for ABC400-1024G and ABC400-1048G Vo Figure 1: ABC400-10XXG block diagram Rev. AA, 19-May-2011 PRELIMINARY Page 2 / 13 www.power-one.com Datasheet pdf - http://www.DataSheet4U.net/ www.DataSheet.co.kr ABC400-10XXG Data Sheet 3 ABSOLUTE MAXIMUM RATINGS Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely affect long-term reliability, and cause permanent damage to the supply. Parameter Conditions / Description Min Nom Max Unit Continuous 264 VAC Vi maxc Max continuous input Transient, 60 ms 300 VAC 4 ENVIRONMENTAL AND MECHANICAL Parameter Ambient temperature TA Extended temp range TAext Storage temperature TS Dimensions M Conditions / Description Vi min to Vi max, Io nom, ISB nom Derated output Non-operational Width Height Depth Min -10 +50 -40 Nom Max +50 +70 +85 Unit C C C mm mm mm kg Max 240 264 6.5 30 60 63 Unit VAC VAC Arms 76.2 38.1 127.0 0.5 Weight 5 INPUT SPECIFICATIONS General Condition: TA = -10... 50 C unless otherwise noted. Active fan air cooling required: 200 LFM (1 m/s) Parameter Vi nom Nominal input voltage Input voltage ranges Vi Max input current Ii max Inrush current limitation Ii p 1) Fi PF Vi on Vi off Input frequency Power factor Turn-on input voltage1) Turn-off input voltage1) Efficiency Thold Hold-up Time Conditions / Description Normal operating (Vi min to Vi max) Min 100 90 Nom Vi nom=115VAC, T= 25C (see Figure 2) Vi nom=230VAC, T= 25C (see Figure 3) Vi nom==264VAC, > 0.5 Io nom Ramping up Ramping down 47 0.9 80 72 50/60 88 80 Vi nom=230VAC, 0.5Io nom, Vo nom, TA = 25 C 89 Vi nom=230VAC, 1.0Io nom, Vo nom, TA = 25 C 90 After last AC zero point, Vo within regulation, Vi = 115 VAC, Po nom Ap Hz W/VA VAC VAC % 16 ms The power supply is provided with a minimum hysteresis of 8 V during turn-on and turn-off within the ranges. Rev. AA, 19-May-2011 PRELIMINARY Page 3 / 13 www.power-one.com Datasheet pdf - http://www.DataSheet4U.net/ www.DataSheet.co.kr ABC400-10XXG Data Sheet 5.1 INPUT FUSE A slow-blow 8A input fuses (5 x 20 mm) in series with live line inside the power supply protects against severe defects. the fuse and a VDR form together with the input filter an effective protection against high input transients. 5.2 INRUSH CURRENT The AC-DC power supply exhibits an X-capacitance of only 1.47 F, resulting in a low and short peak current, when the supply is connected to the mains. the internal bulk capacitor will be charged through an power resistor which will limit the inrush current (see Figure 2 and 3). Figure 3: Inrush current, Vin = 230Vac, 90 CH2: Vin (250V/div), CH3: Iin (10A/div) 5.3 INPUT UNDER-VOLTAGE If the sinusoidal input voltage stays below the input under voltage lockout threshold Vi on, the supply will be inhibited. Once the input voltage returns within the normal operating range, the supply will return to normal operation again. Figure 2: Inrush current, Vin = 115Vac, 90 CH2: Vin (250V/div), CH3: Iin (10A/div) 5.4 POWER FACTOR CORRECTION Power factor correction (PFC) is achieved by controlling the input current waveform synchronously with the input voltage. A specified PFC controller is implemented in the interleaved transition mode topology giving outstanding PFC results over a wide input voltage and load ranges. The input current will follow the shape of the input voltage. 5.5 EFFICIENCY The high efficiency (see Figure 4, 5 and 6) is achieved by using state-of-the-art silicon power devices in conjunction with interleaved transition mode PFC topology minimizing Rev. AA, 19-May-2011 PRELIMINARY Page 4 / 13 www.power-one.com Datasheet pdf - http://www.DataSheet4U.net/ www.DataSheet.co.kr ABC400-10XXG Data Sheet 92.0 90.0 88.0 86.0 84.0 82.0 80.0 78.0 76.0 schottky diode and ultra fast diode are used as rectifiers for ABC400-1024G and ABC400-1048G due to the high output voltage level. 92.0 90.0 88.0 86.0 Series1 84.0 82.0 80.0 78.0 76.0 Efficiency (%) Efficiency (%) switching losses. Synchronous rectifiers on the output reduce the losses in the high current output path for ABC400-1012G . 0 100 200 300 400 Series1 0 100 200 Po (W) Figure 4: Efficiency vs. Output Power at 230VAC, ABC400-1012G Efficiency (%) 300 400 Po (W) 92.0 90.0 88.0 86.0 84.0 82.0 80.0 78.0 76.0 Figure 5: Efficiency vs. Output Power at 230VAC, ABC400-1024G Series1 0 100 200 300 400 Po (W) Figure 6: Efficiency vs. Output Power at 230VAC, ABC400-1048G 6 OUTPUT SPECIFICATIONS G eneral Condition: TA = -10 ... +50 C unless otherwise noted. Active fan air cooling required: 200 LFM (1 m/s) Parameter Main Output VO Vo Nominal output voltage Rev. AA, 19-May-2011 PRELIMINARY Conditions / Description 0.5 IO, Tamb = 25 C Min ABC400-1012G ABC400-1024G ABC400-1048G Page 5 / 13 Nom 12.0 24.0 48.0 Max Unit VDC VDC VDC www.power-one.com Datasheet pdf - http://www.DataSheet4U.net/ www.DataSheet.co.kr ABC400-10XXG Data Sheet Vo set Po nom Io nom Vo p-p dVo Load Output set accuracy point 0.5 IO, Tamb = 25 C Nominal output power Nominal output current Output ripple voltage Load regulation Vo nom, Io BW nom, 20 MHz Vi = Vi nom, 0 - 100 % Io nom dVo Line dVdyn Line regulation Dynamic regulation trec Recovery time tdelay Turn-on Delay trise CLoad Turn on Rise time Capacitive loading Rev. AA, 19-May-2011 PRELIMINARY Vi =Vi min...Vi max Io = 50% Io nom, Io = 50 ... 100% Io nom, load dI /dt = 1 A/s, o recovery within 5% of Vo nom ABC400-1012G -50 50 mV ABC400-1024G -75 75 mV ABC400-1048G -150 150 mV ABC400-1012G 0 276 360 W ABC400-1024G 0 312 408 W ABC400-1048G 0 312 408 W ABC400-1012G 0 23 30 A ABC400-1024G 0 13 17 A ABC400-1048G 0 6.5 8.5 A ABC400-1012G 60 120 mVpp ABC400-1024G 80 240 mVpp ABC400-1048G 150 480 mVpp ABC400-1012G -360 50 360 mV ABC400-1024G -720 80 720 mV ABC400-1048G -1440 130 1440 mV ABC400-1012G -360 80 360 mV ABC400-1024G -720 120 720 mV ABC400-1048G -1440 150 1440 mV ABC400-1012G -0.6 0.25 0.6 V ABC400-1024G -1.2 0.45 1.2 V ABC400-1048G -2.4 0.7 2.4 V 2 ms 2 Sec ABC400-1012G 20 ms ABC400-1024G 20 ms ABC400-1048G 30 ms ABC400-1012G 6600 F ABC400-1024G 3740 F ABC400-1048G 1870 F Time required for output within regulation after intial application of AC input @90 Vac VO = 10...90% VO nom Page 6 / 13 0 1 www.power-one.com Datasheet pdf - http://www.DataSheet4U.net/ www.DataSheet.co.kr ABC400-10XXG Data Sheet Figure 7: Turn-On AC Line 115 VAC, full load (200 ms/div) CH1: Vo (10 V/div) CH2: Vin (100 V/div) Figure 8: Turn-On AC Line 230 VAC, full load (200 ms/div) CH1: Vo (10 V/div) CH2: Vin (100 V/div) Figure 9: Turn-Off AC Line 115 VAC, full load (10 ms/div) CH1: Vo (10 V/div) CH2: Vin (100 V/div) Figure 10: AC drop out 16ms (100 ms/div) CH1: Vo (10 V/div) CH2: Vin (100 V/div) Figure 11: Figure 12: Vo rise time at 115VAC (20 ms/div) CH1: Vo (10 V/div) AC drop out 30ms (500 ms/div), Vo restart CH1: Vo (10 V/div) CH2: Vin (200 V/div) Rev. AA, 19-May-2011 PRELIMINARY Page 7 / 13 www.power-one.com Datasheet pdf - http://www.DataSheet4U.net/ www.DataSheet.co.kr ABC400-10XXG Data Sheet Figure 13: Load transient Vo (500s/div), 8.5A <-> 17A 2A/s CH1: Vo (200mV/div) CH2: Io (5.0 A/div) Figure 14: Load transient Vo (1.0ms/div), 8.5A <-> 17A, 2A/s CH1: Vo (200 mV/div) CH2: Io (5 A/div) 7 PROTECTION Parameter Input fuses (L only) F Vo ov Io lim TSD OV threshold Current limit Over temperature on heat sinks Conditions / Description Not user accessible, time lag characteristic ABC400-1012G ABC400-1024G ABC400-1048G ABC400-1012G Vi > 90 VAC, -10 C ABC400-1024G