ADC10D1000,ADC10D1500 ADC10D1000/ADC10D1500 Low Power, 10-Bit, Dual 1.0/1.5 GSPS or Single 2.0/3.0 GSPS ADC Literature Number: SNAS462P ADC10D1000/ADC10D1500 Low Power, 10-Bit, Dual 1.0/1.5 GSPS or Single 2.0/3.0 GSPS ADC 1.0 General Description 2.0 Features The ADC10D1000/1500 is the latest advance in National's Ultra-High-Speed ADC family. This low-power, high-performance CMOS analog-to-digital converter digitizes signals at 10-bit resolution for dual channels at sampling rates of up to 1.0/1.5 GSPS (Non-DES Mode) or for a single channel up to 2.0/3.0 GSPS (DES Mode). The ADC10D1000/1500 achieves excellent accuracy and dynamic performance while dissipating less than 2.8/3.6 Watts. The product is packaged in a leaded or lead-free 292-ball thermally enhanced BGA package over the rated industrial temperature range of -40C to +85C. The ADC10D1000/1500 builds upon the features, architecture and functionality of the 8-bit GHz family of ADCs. An expanded feature set includes AutoSync for multi-chip synchronization, 15-bit programmable gain and 12-bit plus sign programmable offset adjustment for each channel. The improved internal track-and-hold amplifier and the extended self-calibration scheme enable a very flat response of all dynamic parameters beyond Nyquist, producing 9.1/9.0 Effective Number of Bits (ENOB) with a 100 MHz input signal and a 1.0/1.5 GHz sample rate while providing a 10-18 Code Error Rate (CER) Dissipating a typical 2.77/3.59 Watts in Non-Demultiplex Mode at 1.0/1.5 GSPS from a single 1.9V supply, this device is guaranteed to have no missing codes over the full operating temperature range. Each channel has its own independent DDR Data Clock, DCLKI and DCLKQ, which are in phase when both channels are powered up, so that only one Data Clock could be used to capture all data, which is sent out at the same rate as the input sample clock. If the 1:2 Demux Mode is selected, a second 10-bit LVDS bus becomes active for each channel, such that the output data rate is sent out two times slower to relax data-capture timing requirements. The part can also be used as a single 2.0/3.0 GSPS ADC to sample one of the I or Q inputs. The output formatting can be programmed to be offset binary or two's complement and the Low Voltage Differential Signaling (LVDS) digital outputs are compatible with IEEE 1596.3-1996, with the exception of an adjustable common mode voltage between 0.8V and 1.2V to allow for power reduction for well-controlled back planes. Excellent accuracy and dynamic performance Pin compatible with ADC12D1000/1600/1800 Low power consumption, further reduced at lower Fs Internally terminated, buffered, differential analog inputs R/W SPI Interface for Extended Control Mode Dual-Edge Sampling Mode, in which the I- and Q-channels sample one input at twice the sampling clock rate Test patterns at output for system debug Programmable 15-bit gain and 12-bit plus sign offset Programmable tAD adjust feature 1:1 non-demuxed or 1:2 demuxed LVDS outputs AutoSync feature for multi-chip systems Single 1.9V 0.1V power supply 292-ball BGA package (27mm x 27mm x 2.4mm with 1.27mm ball-pitch); no heat sink required 3.0 Key Specifications (Non-Demux Non-DES Mode, Fs=1.0/1.5 GSPS, Fin = 100 MHz) 10 Bits Resolution Conversion Rate -- Dual channels at 1.0/1.5 GSPS (typ) -- Single channel at 2.0/3.0 GSPS (typ) 10-18/10-18 (typ) Code Error Rate 9.1/9.0 bits (typ) ENOB 57/56.8 dB (typ) SNR 70/68 dBc (typ) SFDR 2.8/2.8 GHz (typ) Full Power Bandwidth 0.25/0.25 LSB (typ) DNL Power Consumption 1.61/1.92W (typ) -- Single Channel Enabled 2.77/3.59W (typ) -- Dual Channels Enabled 6/6 mW (typ) -- Power Down Mode 4.0 Applications Wideband Communications Data Acquisition Systems Digital Oscilloscopes 5.0 Ordering Information Industrial Temperature Range (-40C < TA < +85C) NS Package ADC10D1000/1500CIUT/NOPB Lead-free 292-Ball BGA Thermally Enhanced Package ADC10D1000/1500CIUT Leaded 292-Ball BGA Thermally Enhanced Package ADC10D1000/1500RB Reference Board If Military/Aerospace specified devices are required, please contract the National Semiconductor Sales Office/Distributors for availability and specifications. IBIS models are available at: http://www.national.com/analog/adc/ ibis_models. (c) 2011 National Semiconductor Corporation 300663 www.national.com ADC10D1000/1500 Low Power, 10-Bit, Dual 1.0/1.5 GSPS or Single 2.0/3.0 GSPS ADC October 19, 2011 ADC10D1000/1500 6.0 Block Diagram 30066353 FIGURE 1. Simplified Block Diagram www.national.com 2 1.0 General Description ......................................................................................................................... 1 2.0 Features ........................................................................................................................................ 1 3.0 Key Specifications ........................................................................................................................... 1 4.0 Applications .................................................................................................................................... 1 5.0 Ordering Information ....................................................................................................................... 1 6.0 Block Diagram ................................................................................................................................ 2 7.0 Connection Diagram ........................................................................................................................ 6 8.0 Ball Descriptions and Equivalent Circuits ............................................................................................ 7 9.0 Absolute Maximum Ratings ............................................................................................................ 16 10.0 Operating Ratings ....................................................................................................................... 16 11.0 Converter Electrical Characteristics ................................................................................................ 16 12.0 Specification Definitions ................................................................................................................ 27 13.0 Transfer Characteristic ................................................................................................................. 29 14.0 Timing Diagrams ......................................................................................................................... 30 15.0 Typical Performance Plots ............................................................................................................ 33 16.0 Functional Description .................................................................................................................. 43 16.1 OVERVIEW ......................................................................................................................... 43 16.2 CONTROL MODES .............................................................................................................. 43 16.2.1 Non-Extended Control Mode ........................................................................................ 43 16.2.1.1 Dual Edge Sampling Pin (DES) ........................................................................... 43 16.2.1.2 Non-Demultiplexed Mode Pin (NDM) ................................................................... 43 16.2.1.3 Dual Data Rate Phase Pin (DDRPh) .................................................................... 44 16.2.1.4 Calibration Pin (CAL) ......................................................................................... 44 16.2.1.5 Calibration Delay Pin (CalDly) ............................................................................ 44 16.2.1.6 Power Down I-channel Pin (PDI) ......................................................................... 44 16.2.1.7 Power Down Q-channel Pin (PDQ) ...................................................................... 44 16.2.1.8 Test Pattern Mode Pin (TPM) ............................................................................. 44 16.2.1.9 Full-Scale Input Range Pin (FSR) ....................................................................... 44 16.2.1.10 AC/DC-Coupled Mode Pin (VCMO) ..................................................................... 44 16.2.1.11 LVDS Output Common-mode Pin (VBG) ............................................................. 44 16.2.2 Extended Control Mode ............................................................................................... 45 16.2.2.1 The Serial Interface ........................................................................................... 45 16.3 FEATURES ......................................................................................................................... 47 16.3.1 Input Control and Adjust .............................................................................................. 48 16.3.1.1 AC/DC-coupled Mode ........................................................................................ 48 16.3.1.2 Input Full-Scale Range Adjust ............................................................................ 48 16.3.1.3 Input Offset Adjust ............................................................................................ 48 16.3.1.4 DES/Non-DES Mode ......................................................................................... 48 16.3.1.5 Sampling Clock Phase Adjust ............................................................................. 48 16.3.1.6 LC Filter on Sampling Clock ............................................................................... 48 16.3.1.7 VCMO Adjust ..................................................................................................... 49 16.3.2 Output Control and Adjust ............................................................................................ 49 16.3.2.1 DDR Clock Phase ............................................................................................. 49 16.3.2.2 LVDS Output Differential Voltage ........................................................................ 49 16.3.2.3 LVDS Output Common-Mode Voltage ................................................................. 49 16.3.2.4 Output Formatting ............................................................................................. 49 16.3.2.5 Demux/Non-demux Mode .................................................................................. 49 16.3.2.6 Test Pattern Mode ............................................................................................ 49 16.3.3 Calibration Feature ..................................................................................................... 50 16.3.3.1 Calibration Control Pins and Bits ......................................................................... 50 16.3.3.2 How to Execute a Calibration .............................................................................. 50 16.3.3.3 Power-on Calibration ......................................................................................... 50 16.3.3.4 On-command Calibration ................................................................................... 51 16.3.3.5 Calibration Adjust .............................................................................................. 51 16.3.3.6 Read/Write Calibration Settings .......................................................................... 51 16.3.3.7 Calibration and Power-Down .............................................................................. 51 16.3.3.8 Calibration and the Digital Outputs ...................................................................... 51 16.3.4 Power Down .............................................................................................................. 51 17.0 Applications Information ............................................................................................................... 52 17.1 THE ANALOG INPUTS ......................................................................................................... 52 17.1.1 Acquiring the Input ...................................................................................................... 52 17.1.2 Driving the ADC in DES Mode ...................................................................................... 52 17.1.3 Terminating Unused Analog Inputs ............................................................................... 52 17.1.4 FSR and the Reference Voltage ................................................................................... 53 3 www.national.com ADC10D1000/1500 Table of Contents ADC10D1000/1500 17.1.5 Out-Of-Range Indication .............................................................................................. 17.1.6 Maximum Input Range ................................................................................................ 17.1.7 AC-coupled Input Signals ............................................................................................ 17.1.8 DC-coupled Input Signals ............................................................................................ 17.1.9 Single-Ended Input Signals .......................................................................................... 17.2 THE CLOCK INPUTS ........................................................................................................... 17.2.1 CLK Coupling ............................................................................................................. 17.2.2 CLK Frequency .......................................................................................................... 17.2.3 CLK Level .................................................................................................................. 17.2.4 CLK Duty Cycle .......................................................................................................... 17.2.5 CLK Jitter .................................................................................................................. 17.2.6 CLK Layout ................................................................................................................ 17.3 THE LVDS OUTPUTS ........................................................................................................... 17.3.1 Common-mode and Differential Voltage ......................................................................... 17.3.2 Output Data Rate ........................................................................................................ 17.3.3 Terminating RSV Pins ................................................................................................. 17.3.4 Terminating Unused LVDS Output Pins ......................................................................... 17.4 SYNCHRONIZING MULTIPLE ADC10D1000/1500S IN A SYSTEM ............................................ 17.4.1 AutoSync Feature ....................................................................................................... 17.4.2 DCLK Reset Feature ................................................................................................... 17.5 SUPPLY/GROUNDING, LAYOUT AND THERMAL RECOMMENDATIONS ................................. 17.5.1 Power Planes ............................................................................................................. 17.5.2 Bypass Capacitors ...................................................................................................... 17.5.3 Ground Planes ........................................................................................................... 17.5.4 Power System Example ............................................................................................... 17.5.5 Thermal Management ................................................................................................. 17.6 SYSTEM POWER-ON CONSIDERATIONS ............................................................................. 17.6.1 Power-on, Configuration, and Calibration ....................................................................... 17.6.2 Power-on and Data Clock (DCLK) ................................................................................. 17.7 RECOMMENDED SYSTEM CHIPS ........................................................................................ 17.7.1 Temperature Sensor ................................................................................................... 17.7.2 Clocking Device ......................................................................................................... 17.7.3 Amplifier .................................................................................................................... 18.0 Register Definitions ...................................................................................................................... 19.0 Physical Dimensions .................................................................................................................... 53 53 53 53 53 54 54 54 54 54 54 54 54 54 54 55 55 55 55 56 56 56 56 56 56 58 58 58 60 60 60 61 61 62 69 List of Figures FIGURE 1. Simplified Block Diagram ............................................................................................................. 2 FIGURE 2. ADC10D1000/1500 Connection Diagram ......................................................................................... 6 FIGURE 3. LVDS Output Signal Levels ......................................................................................................... 27 FIGURE 4. Input / Output Transfer Characteristic ............................................................................................ 29 FIGURE 5. Clocking in 1:2 Demux Non-DES Mode* ......................................................................................... 30 FIGURE 6. Clocking in Non-Demux Non-DES Mode* ........................................................................................ 30 FIGURE 7. Clocking in 1:4 Demux DES Mode* ............................................................................................... 31 FIGURE 8. Clocking in Non-Demux Mode DES Mode* ...................................................................................... 31 FIGURE 9. Data Clock Reset Timing (Demux Mode) ........................................................................................ 32 FIGURE 10. Power-on and On-Command Calibration Timing .............................................................................. 32 FIGURE 11. Serial Interface Timing ............................................................................................................. 32 FIGURE 12. Serial Data Protocol - Read Operation .......................................................................................... 45 FIGURE 13. Serial Data Protocol - Write Operation .......................................................................................... 46 FIGURE 14. DDR DCLK-to-Data Phase Relationship ........................................................................................ 49 FIGURE 15. Driving DESIQ Mode ............................................................................................................... 52 FIGURE 16. AC-coupled Differential Input ..................................................................................................... 53 FIGURE 17. Single-Ended to Differential Conversion Using a Balun ...................................................................... 53 FIGURE 18. Differential Input Clock Connection .............................................................................................. 54 FIGURE 19. RSV Pin Connection ................................................................................................................ 55 FIGURE 20. AutoSync Example ................................................................................................................. 55 FIGURE 21. Power and Grounding Example .................................................................................................. 57 FIGURE 22. HSBGA Conceptual Drawing ..................................................................................................... 58 FIGURE 23. Power-on with Control Pins set by Pull-up/down Resistors .................................................................. 59 FIGURE 24. Power-on with Control Pins set by FPGA pre Power-on Cal ................................................................ 59 FIGURE 25. Power-on with Control Pins set by FPGA post Power-on Cal ............................................................... 60 FIGURE 26. Supply and DCLK Ramping ....................................................................................................... 60 FIGURE 27. Typical Temperature Sensor Application ....................................................................................... 61 www.national.com 4 TABLE 1. Analog Front-End and Clock Balls ................................................................................................... 7 TABLE 2. Control and Status Balls .............................................................................................................. 10 TABLE 3. Power and Ground Balls .............................................................................................................. 13 TABLE 4. High-Speed Digital Outputs .......................................................................................................... 14 TABLE 5. Package Thermal Resistance ........................................................................................................ 16 TABLE 6. Static Converter Characteristics ..................................................................................................... 16 TABLE 7. Dynamic Converter Characteristics ................................................................................................ 17 TABLE 8. Analog Input/Output and Reference Characteristics ............................................................................. 20 TABLE 9. I-Channel to Q-Channel Characteristics ............................................................................................ 21 TABLE 10. Sampling Clock Characteristics ................................................................................................... 21 TABLE 11. Digital Control and Output Pin Characteristics ................................................................................... 22 TABLE 12. Power Supply Characteristics ...................................................................................................... 23 TABLE 13. AC Electrical Characteristics ........................................................................................................ 24 TABLE 14. Non-ECM Pin Summary ............................................................................................................. 43 TABLE 15. Serial Interface Pins .................................................................................................................. 45 TABLE 16. Command and Data Field Definitions ............................................................................................. 45 TABLE 17. Features and Modes ................................................................................................................ 47 TABLE 18. LC Filter Code vs. fc .................................................................................................................. 49 TABLE 19. LC Filter Bandwidth vs. Level ....................................................................................................... 49 TABLE 20. Test Pattern by Output Port in Demux Mode .................................................................................... 50 TABLE 21. Test Pattern by Output Port in Non-Demux Mode .............................................................................. 50 TABLE 22. Calibration Pins ....................................................................................................................... 50 TABLE 23. Output Latency in Demux Mode ................................................................................................... 52 TABLE 24. Output Latency in Non-Demux Mode ............................................................................................. 52 TABLE 25. Unused Analog Input Recommended Termination ............................................................................. 52 TABLE 26. Unused AutoSync and DCLK Reset Pin Recommendation ................................................................... 55 TABLE 27. Temperature Sensor Recommendation .......................................................................................... 60 TABLE 28. Amplifier Recommendation ......................................................................................................... 61 TABLE 29. Register Addresses .................................................................................................................. 62 5 www.national.com ADC10D1000/1500 List of Tables ADC10D1000/1500 7.0 Connection Diagram 30066301 FIGURE 2. ADC10D1000/1500 Connection Diagram The center ground pins are for thermal dissipation and must be soldered to a ground plane to ensure rated performance. See Section 17.5 SUPPLY/GROUNDING, LAYOUT AND THERMAL RECOMMENDATIONS for more information. www.national.com 6 TABLE 1. Analog Front-End and Clock Balls Ball No. Name H1/J1 N1/M1 VinI+/VinQ+/- U2/V1 V2/W1 Equivalent Circuit Description Differential signal I- and Q-inputs. In the Non-Dual Edge Sampling (Non-DES) Mode, each I- and Q-input is sampled and converted by its respective channel with each positive transition of the CLK input. In Non-ECM (Non-Extended Control Mode) and DES Mode, both channels sample the I-input. In Extended Control Mode (ECM), the Qinput may optionally be selected for conversion in DES Mode by the DEQ Bit (Addr: 0h, Bit 6). Each I- and Q-channel input has an internal common mode bias that is disabled when DC-coupled Mode is selected. Both inputs must be either AC- or DC-coupled. The coupling mode is selected by the VCMO Pin. In Non-ECM, the full-scale range of these inputs is determined by the FSR Pin; both I- and Qchannels have the same full-scale input range. In ECM, the full-scale input range of the I- and Qchannel inputs may be independently set via the Control Register (Addr: 3h and Addr: Bh). Note that the high and low full-scale input range setting in Non-ECM corresponds to the mid and minimum full-scale input range in ECM. The input offset may also be adjusted in ECM. CLK+/- Differential Converter Sampling Clock. In the Non-DES Mode, the analog inputs are sampled on the positive transitions of this clock signal. In the DES Mode, the selected input is sampled on both transitions of this clock. This clock must be AC-coupled. DCLK_RST+/- Differential DCLK Reset. A positive pulse on this input is used to reset the DCLKI and DCLKQ outputs of two or more ADC10D1000/1500s in order to synchronize them with other ADC10D1000/1500s in the system. DCLKI and DCLKQ are always in phase with each other, unless one channel is powered down, and do not require a pulse from DCLK_RST to become synchronized. The pulse applied here must meet timing relationships with respect to the CLK input. Although supported, this feature has been superseded by AutoSync. 7 www.national.com ADC10D1000/1500 8.0 Ball Descriptions and Equivalent Circuits ADC10D1000/1500 Ball No. C2 B1 C3/D3 C1/D2 E2/F3 www.national.com Name Equivalent Circuit Description VCMO Common Mode Voltage Output or Signal Coupling Select. If AC-coupled operation at the analog inputs is desired, this pin should be held at logic-low level. This pin is capable of sourcing/ sinking up to 100 A. For DC-coupled operation, this pin should be left floating or terminated into high-impedance. In DC-coupled Mode, this pin provides an output voltage which is the optimal common-mode voltage for the input signal and should be used to set the common-mode voltage of the driving buffer. VBG Bandgap Voltage Output or LVDS Commonmode Voltage Select. This pin provides a buffered version of the bandgap output voltage and is capable of sourcing/sinking 100 uA and driving a load of up to 80 pF. Alternately, this pin may be used to select the LVDS digital output common-mode voltage. If tied to logic-high, the 1.2V LVDS common-mode voltage is selected; 0.8V is the default. Rext+/- External Reference Resistor terminals. A 3.3 k 0.1% resistor should be connected between Rext+/-. The Rext resistor is used as a reference to trim internal circuits which affect the linearity of the converter; the value and precision of this resistor should not be compromised. Rtrim+/- Input Termination Trim Resistor terminals. A 3.3 k 0.1% resistor should be connected between Rtrim+/-. The Rtrim resistor is used to establish the calibrated 100 input impedance of VinI, VinQ and CLK. These impedances may be fine tuned by varying the value of the resistor by a corresponding percentage; however, the tuning range and performance is not guaranteed for such an alternate value. Tdiode+/- Temperature Sensor Diode Positive (Anode) and Negative (Cathode) Terminals. This set of pins is used for die temperature measurements. It has not been fully characterized. 8 Y4/W5 Y5/U6 V6/V7 Name Equivalent Circuit Description RCLK+/- Reference Clock Input. When the AutoSync feature is active, and the ADC10D1000/1500 is in Slave Mode, the internal divided clocks are synchronized with respect to this input clock. The delay on this clock may be adjusted when synchronizing multiple ADCs. This feature is available in ECM via Control Register (Addr: Eh). RCOut1+/RCOut2+/- Reference Clock Output 1 and 2. These signals provide a reference clock at a rate of CLK/4, when enabled, independently of whether the ADC is in Master or Slave Mode. They are used to drive the RCLK of another ADC10D1000/1500, to enable automatic synchronization for multiple ADCs (AutoSync feature). The impedance of each trace from RCOut1 and RCOut2 to the RCLK of another ADC10D1000/1500 should be 100 differential. Having two clock outputs allows the autosynchronization to propagate as a binary tree. Use the DOC Bit (Addr: Eh, Bit 1) to enable/ disable this feature; default is disabled. 9 www.national.com ADC10D1000/1500 Ball No. ADC10D1000/1500 TABLE 2. Control and Status Balls Ball No. Name Equivalent Circuit Description DES Dual Edge Sampling (DES) Mode select. In the Non-Extended Control Mode (Non-ECM), when this input is set to logic-high, the DES Mode of operation is selected, meaning that the VinI input is sampled by both channels in a time-interleaved manner. The VinQ input is ignored. When this input is set to logic-low, the device is in Non-DES Mode, i.e. the I- and Q-channels operate independently. In the Extended Control Mode (ECM), this input is ignored and DES Mode selection is controlled through the Control Register by the DES Bit (Addr: 0h, Bit 7); default is Non-DES Mode operation. CalDly Calibration Delay select. By setting this input logic-high or logic-low, the user can select the device to wait a longer or shorter amount of time, respectively, before the automatic power-on selfcalibration is initiated. This feature is pincontrolled only and is always active during ECM and Non-ECM. D6 CAL Calibration cycle initiate. The user can command the device to execute a self-calibration cycle by holding this input high a minimum of tCAL_H after having held it low a minimum of tCAL_L. If this input is held high at the time of power-on, the automatic power-on calibration cycle is inhibited until this input is cycled low-then-high. This pin is active in both ECM and Non-ECM. In ECM, this pin is logically OR'd with the CAL Bit (Addr: 0h, Bit 15) in the Control Register. Therefore, both pin and bit must be set low and then either can be set high to execute an on-command calibration. B5 CalRun V5 V4 www.national.com Calibration Running indication. This output is logic-high while the calibration sequence is executing. This output is logic-low otherwise. 10 U3 V3 A4 A5 Name Equivalent Circuit Description PDI PDQ Power Down I- and Q-channel. Setting either input to logic-high powers down the respective Ior Q-channel. Setting either input to logic-low brings the respective I- or Q-channel to a operational state after a finite time delay. This pin is active in both ECM and Non-ECM. In ECM, each Pin is logically OR'd with its respective Bit. Therefore, either this pin or the PDI and PDQ Bit in the Control Register can be used to powerdown the I- and Q-channel (Addr: 0h, Bit 11 and Bit 10), respectively. TPM Test Pattern Mode select. With this input at logichigh, the device continuously outputs a fixed, repetitive test pattern at the digital outputs. In the ECM, this input is ignored and the Test Pattern Mode can only be activated through the Control Register by the TPM Bit (Addr: 0h, Bit 12). NDM Non-Demuxed Mode select. Setting this input to logic-high causes the digital output bus to be in the 1:1 Non-Demuxed Mode. Setting this input to logic-low causes the digital output bus to be in the 1:2 Demuxed Mode. This feature is pin-controlled only and remains active during ECM and NonECM. Y3 FSR W4 DDRPh Full-Scale input Range select. In Non-ECM, when this input is set to logic-low or logic-high, the full-scale differential input range for both Iand Q-channel inputs is set to the lower or higher FSR value, respectively. In the ECM, this input is ignored and the full-scale range of the I- and Qchannel inputs is independently determined by the setting of Addr: 3h and Addr: Bh, respectively. Note that the high (lower) FSR value in NonECM corresponds to the mid (min) available selection in ECM; the FSR range in ECM is greater. DDR Phase select. This input, when logic-low, selects the 0 Data-to-DCLK phase relationship. When logic-high, it selects the 90 Data-to-DCLK phase relationship, i.e. the DCLK transition indicates the middle of the valid data outputs. This pin only has an effect when the chip is in 1:2 Demuxed Mode, i.e. the NDM pin is set to logiclow. In ECM, this input is ignored and the DDR phase is selected through the Control Register by the DPS Bit (Addr: 0h, Bit 14); the default is 0 Mode. 11 www.national.com ADC10D1000/1500 Ball No. ADC10D1000/1500 Ball No. Name Equivalent Circuit Description ECE Extended Control Enable bar. Extended feature control through the SPI interface is enabled when this signal is asserted (logic-low). In this case, most of the direct control pins have no effect. When this signal is de-asserted (logic-high), the SPI interface is disabled, all SPI registers are reset to their default values, and all available settings are controlled via the control pins. SCS Serial Chip Select bar. In ECM, when this signal is asserted (logic-low), SCLK is used to clock in serial data which is present on SDI and to source serial data on SDO. When this signal is deasserted (logic-high), SDI is ignored and SDO is in tri-stated. C5 SCLK Serial Clock. In ECM, serial data is shifted into and out of the device synchronously to this clock signal. This clock may be disabled and held logiclow, as long as timing specifications are not violated when the clock is enabled or disabled. B4 SDI Serial Data-In. In ECM, serial data is shifted into the device on this pin while SCS signal is asserted (logic-low). A3 SDO Serial Data-Out. In ECM, serial data is shifted out of the device on this pin while SCS signal is asserted (logic-low). This output is tri-stated when SCS is de-asserted. D1, D7, E3, F4, W3, U7 DNC NONE Do Not Connect. These pins are used for internal purposes and should not be connected, i.e. left floating. Do not ground. C7 NC NONE Not Connected. This pin is not bonded and may be left floating or connected to any potential. B3 C4 www.national.com 12 Ball No. Name Equivalent Circuit A2, A6, B6, C6, D8, D9, E1, F1, H4, N4, R1, T1, U8, U9, W6, Y2, Y6 VA NONE Power Supply for the Analog circuitry. This supply is tied to the ESD ring. Therefore, it must be powered up before or with any other supply. G1, G3, G4, H2, J3, K3, L3, M3, N2, P1, P3, P4, R3, R4 VTC NONE Power Supply for the Track-and-Hold and Clock circuitry. A11, A15, C18, D11, D15, D17, J17, J20, R17, R20, T17, U11, U15, U16, Y11, Y15 VDR NONE Power Supply for the Output Drivers. A8, B9, C8, V8, W9, Y8 VE NONE Power Supply for the Digital Encoder. NONE Bias Voltage I-channel. This is an externally decoupled bias voltage for the I-channel. Each pin should individually be decoupled with a 100 nF capacitor via a low resistance, low inductance path to GND. J4, K2 VbiasI Description L2, M4 VbiasQ NONE Bias Voltage Q-channel. This is an externally decoupled bias voltage for the Q-channel. Each pin should individually be decoupled with a 100 nF capacitor via a low resistance, low inductance path to GND. A1, A7, B2, B7, D4, D5, E4, K1, L1, T4, U4, U5, W2, W7, Y1, Y7, H8:N13 GND NONE Ground Return for the Analog circuitry. F2, G2, H3, J2, K4, L4, M2, N3, P2, R2, T2, T3, U1 GNDTC NONE Ground Return for the Track-and-Hold and Clock circuitry. A13, A17, A20, D13, D16, E17, F17, F20, M17, M20, U13, U17, V18, Y13, Y17, Y20 GNDDR NONE Ground Return for the Output Drivers. A9, B8, C9, V9, W8, Y9 GNDE NONE Ground Return for the Digital Encoder. 13 www.national.com ADC10D1000/1500 TABLE 3. Power and Ground Balls ADC10D1000/1500 TABLE 4. High-Speed Digital Outputs Ball No. K19/K20 L19/L20 K17/K18 L17/L18 www.national.com Name Equivalent Circuit Description DCLKI+/DCLKQ+/- Data Clock Output for the I- and Q-channel data bus. These differential clock outputs are used to latch the output data and, if used, should always be terminated with a 100 differential resistor placed as closely as possible to the differential receiver. Delayed and non-delayed data outputs are supplied synchronously to this signal. In 1:2 Demux Mode or Non-Demux Mode, this signal is at 1/4 or 1/2 the sampling clock rate, respectively. DCLKI and DCLKQ are always in phase with each other, unless one channel is powered down, and do not require a pulse from DCLK_RST to become synchronized. ORI+/ORQ+/- Out-of-Range Output for the I- and Q-channel. This differential output is asserted logic-high while the over- or under-range condition exists, i.e. the differential signal at each respective analog input exceeds the full-scale value. Each OR result refers to the current Data, with which it is clocked out. If used, each of these outputs should always be terminated with a 100 differential resistor placed as closely as possible to the differential receiver. 14 Name Equivalent Circuit J18/J19 H19/H20 H17/H18 G19/G20 G17/G18 F18/F19 E19/E20 D19/D20 D18/E18 C19/C20 * M18/M19 N19/N20 N17/N18 P19/P20 P17/P18 R18/R19 T19/T20 U19/U20 U18/T18 V19/V20 DI9+/DI8+/DI7+/DI6+/DI5+/DI4+/DI3+/DI2+/DI1+/DI0+/* DQ9+/DQ8+/DQ7+/DQ6+/DQ5+/DQ4+/DQ3+/DQ2+/DQ1+/DQ0+/- I- and Q-channel Digital Data Outputs. In NonDemux Mode, this LVDS data is transmitted at the sampling clock rate. In Demux Mode, these outputs provide 1/2 the data at 1/2 the sampling clock rate, synchronized with the delayed data, i.e. the other 1/2 of the data which was sampled one clock cycle earlier. Compared with the DId and DQd outputs, these outputs represent the later time samples. If used, each of these outputs should always be terminated with a 100 differential resistor placed as closely as possible to the differential receiver. A18/A19 B17/C16 A16/B16 B15/C15 C14/D14 A14/B14 B13/C13 C12/D12 A12/B12 B11/C11 * Y18/Y19 W17/V16 Y16/W16 W15/V15 V14/U14 Y14/W14 W13/V13 V12/U12 Y12/W12 W11/V11 DId9+/DId8+/DId7+/DId6+/DId5+/DId4+/DId3+/DId2+/DId1+/DId0+/* DQd9+/DQd8+/DQd7+/DQd6+/DQd5+/DQd4+/DQd3+/DQd2+/DQd1+/DQd0+/- Delayed I- and Q-channel Digital Data Outputs. In Non-Demux Mode, these outputs are tristated. In Demux Mode, these outputs provide 1/2 the data at 1/2 the sampling clock rate, synchronized with the non-delayed data, i.e. the other 1/2 of the data which was sampled one clock cycle later. Compared with the DI and DQ outputs, these outputs represent the earlier time samples. If used, each of these outputs should always be terminated with a 100 differential resistor placed as closely as possible to the differential receiver. V10/U10 Y10/W10 W19/W20 W18/V17 B19/B20 B18/C17 C10/D10 A10/B10 RSV7+/RSV6+/RSV5+/RSV4+/RSV3+/RSV2+/RSV1+/RSV0+/- Reserved. These pins are used for internal purposes. They may be left unconnected and floating or connected as recommended in Section 17.3.3 Terminating RSV Pins. NONE 15 Description www.national.com ADC10D1000/1500 Ball No. ADC10D1000/1500 9.0 Absolute Maximum Ratings 10.0 Operating Ratings (Note 1, Note 2) (Note 1, Note 2) Supply Voltage (VA, VTC, VDR, VE) Supply Difference max(VA/TC/DR/E)min(VA/TC/DR/E) Voltage on Any Input Pin (except VIN+/-) VIN+/- Voltage Range Ground Difference max(GNDTC/DR/E) -min(GNDTC/DR/E) Input Current at Any Pin (Note 3) ADC10D1000 Package Power Dissipation at TA 85C (Note 3) ADC10D1500 Package Power Dissipation at TA 70C (Note 3) ESD Susceptibility (Note 4) Human Body Model Charged Device Model Machine Model Storage Temperature Ambient Temperature Range ADC10D1000 2.2V -40C TA +85C -0.15V to 2.5V ADC10D1500 (Standard JEDEC thermal model) ADC10D1500 (Enhanced thermal model/heatsink) Junction Temperature Range 0V to 100 mV 50 mA Supply Voltage (VA, VTC, VE) Driver Supply Voltage (VDR) VIN+/- Voltage Range (Maintaining Common Mode) 0V to 100 mV -0.15V to (VA + 0.15V) 3.7 W -40C TA +70C -40C TA +85C TJ +138C Ground Difference max(GNDTC/DR/E) -min(GNDTC/DR/E) CLK+/- Voltage Range Differential CLK Amplitude Common Mode Input Voltage 4.4 W 2500V 750V 250V -65C to +150C +1.8V to +2.0V +1.8V to VA 0V to 2.15V (100% duty cycle) 0V to 2.5V (10% duty cycle) 0V 0V to VA 0.4VP-P to 2.0VP-P VCMO - 150mV < VCMI < VCMO +150mV TABLE 5. Package Thermal Resistance JA Package JC1 292-Ball BGA Thermally 16C/W Enhanced Package JC2 2.9C/W 2.5C/W Soldering process must comply with National Semiconductor's Reflow Temperature Profile specifications. Refer to www.national.com/packaging. (Note 5) 11.0 Converter Electrical Characteristics The following specifications apply after calibration for VA = VDR = VTC = VE = +1.9V; I- and Q-channels, AC-coupled, unused channel terminated to AC ground, FSR Pin = High; CL = 10 pF; Differential, AC coupled Sine Wave Sampling Clock, fCLK = 1.0/1.5 GHz at 0.5 VP-P with 50% duty cycle (as specified); VBG = Floating; Non-Extended Control Mode; Rext = Rtrim = 3300 0.1%; Analog Signal Source Impedance = 100 Differential; 1:2 Demultiplex Non-DES Mode; Duty Cycle Stabilizer on. Boldface limits apply for TA = TMIN to TMAX. All other limits TA = 25C, unless otherwise noted. (Note 6, Note 7, Note 8, Note 12) TABLE 6. Static Converter Characteristics Symbol Parameter Conditions ADC10D1000 ADC10D1500 Typ Typ Resolution with No Missing Codes Lim 10 Lim Units (Limits) 10 bits INL Integral Non-Linearity (Best fit) 1 MHz DC-coupled over-ranged sine wave 0.65 1.4 0.65 1.4 LSB (max) DNL Differential Non-Linearity 1 MHz DC-coupled over-ranged sine wave 0.25 0.5 0.25 0.55 LSB (max) VOFF Offset Error VOFF_ADJ Input Offset Adjustment Range Extended Control Mode PFSE Positive Full-Scale Error (Note 9) 25 25 mV (max) NFSE Negative Full-Scale Error (Note 9) 25 25 mV (max) 1023 1023 0 0 Out-of-Range Output Code (Note (VIN+) - (VIN-) > + Full Scale 10) (VIN+) - (VIN-) < - Full Scale www.national.com 16 -2 -2 LSB 45 45 mV Symbol FPBW Parameter Full Power Bandwidth Gain Flatness CER Code Error Rate NPR Noise Power Ratio Conditions ADC10D1000 ADC10D1500 Typ Typ Lim Lim Units (Limits) Non-DES Mode 2.8 2.8 GHz DES Mode 1.25 1.25 GHz DESIQ Mode 1.75 1.75 GHz D.C. to Fs/2 0.35 0.4 dBFS D.C. to Fs 0.5 1.2 dBFS 10-18 10-18 Error/ Sample fc,notch = 325 MHz, Notch width = 5% 48 48 dB AIN = 100 MHz @ -0.5 dBFS 9.1 9.0 bits AIN = 248 MHz @ -0.5 dBFS 9.1 1:2 Demux Non-DES Mode ENOB Effective Number of Bits 8.3 AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS 8.8 9.0 Signal-to-Noise Plus Distortion Ratio AIN = 100 MHz @ -0.5 dBFS 56.5 AIN = 248 MHz @ -0.5 dBFS 56.5 52 AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS Signal-to-Noise Ratio 57 AIN = 248 MHz @ -0.5 dBFS 57 52.7 56.5 52.7 AIN = 373 MHz @ -0.5 dBFS Total Harmonic Distortion AIN = 100 MHz @ -0.5 dBFS -67 AIN = 248 MHz @ -0.5 dBFS -69 -60 AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS Second Harmonic Distortion -66 dB 56.8 dB 56.4 dB (min) dB (min) 50 dB (min) 55 dB -65 dB -63 dB (max) -53.6 dB (max) dB (max) -63 dB -76 -76 dBc -71 -71 dBc -71 dBc -71 dBc -70 dBc AIN = 100 MHz @ -0.5 dBFS -70 -68 dBc AIN = 248 MHz @ -0.5 dBFS -70 -72 dBc -63 dBc AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS -69 dBc AIN = 748 MHz @ -0.5 dBFS Spurious-Free Dynamic Range dB (min) AIN = 248 MHz @ -0.5 dBFS AIN = 748 MHz @ -0.5 dBFS SFDR dB (min) AIN = 100 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS Third Harmonic Distortion dB (min) 48.4 -60 AIN = 373 MHz @ -0.5 dBFS 3rd Harm 55.6 -60 AIN = 748 MHz @ -0.5 dBFS 2nd Harm dB 56.4 AIN = 748 MHz @ -0.5 dBFS THD bits 56.1 54.5 AIN = 100 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS bits (min) 52 AIN = 748 MHz @ -0.5 dBFS SNR bits (min) 8.8 54.9 56 bits (min) 7.8 8.3 AIN = 748 MHz @ -0.5 dBFS SINAD 8.9 -65 AIN = 100 MHz @ -0.5 dBFS 70 AIN = 248 MHz @ -0.5 dBFS 66 57.9 66 57.9 AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS AIN = 748 MHz @ -0.5 dBFS 17 dBc 68 dBc 68 dBc (min) 63 54 dBc (min) dBc (min) 65 dBc www.national.com ADC10D1000/1500 TABLE 7. Dynamic Converter Characteristics ADC10D1000/1500 Symbol Parameter Conditions ADC10D1000 ADC10D1500 Typ Typ Lim Lim Units (Limits) Non-Demux Non-DES Mode(Note 12) ENOB Effective Number of Bits AIN = 100 MHz @ -0.5 dBFS 9.1 AIN = 248 MHz @ -0.5 dBFS 9.1 9.1 8.4 AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS 9.1 8.8 9.0 8.3 bits bits (min) 7.8 9.0 bits (min) AIN = 748 MHz @ -0.5 dBFS SINAD Signal-to-Noise Plus Distortion Ratio bits AIN = 100 MHz @ -0.5 dBFS 56.6 AIN = 248 MHz @ -0.5 dBFS 56.5 52.6 56 52.0 AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS 56.5 dB 56.5 dB (min) 54.5 48.4 56 Signal-to-Noise Ratio dB AIN = 100 MHz @ -0.5 dBFS 57 AIN = 248 MHz @ -0.5 dBFS 57 57 53.5 AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS 57 55.5 56.5 52.7 dB dB (min) 50 56.5 Total Harmonic Distortion dB AIN = 100 MHz @ -0.5 dBFS -67 AIN = 248 MHz @ -0.5 dBFS -66 -60 -66 -60 AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS -67 dB -66 dB (max) -60 -53.6 Second Harmonic Distortion dB (max) dB AIN = 100 MHz @ -0.5 dBFS -85 -85 dBc AIN = 248 MHz @ -0.5 dBFS -71 -71 dBc AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS dBc -71 -71 dBc AIN = 748 MHz @ -0.5 dBFS 3rd Harm Third Harmonic Distortion dBc AIN = 100 MHz @ -0.5 dBFS -68 -68 dBc AIN = 248 MHz @ -0.5 dBFS -70 -70 dBc -70 -70 AIN = 100 MHz @ -0.5 dBFS 68 68 AIN = 248 MHz @ -0.5 dBFS 66 AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS dBc dBc AIN = 748 MHz @ -0.5 dBFS SFDR Spurious-Free Dynamic Range dBc 59 AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS AIN = 748 MHz @ -0.5 dBFS www.national.com dB (max) -66 AIN = 748 MHz @ -0.5 dBFS 2nd Harm dB (min) dB (min) AIN = 748 MHz @ -0.5 dBFS THD dB (min) dB (min) AIN = 748 MHz @ -0.5 dBFS SNR bits (min) 18 66 63 66 57.9 dBc 66 dBc (min) 54 dBc (min) dBc (min) dBc Parameter Conditions ADC10D1000 ADC10D1500 Typ Typ Lim Lim Units (Limits) DES Mode (Demux and Non-Demux Modes, Q-input only) ENOB Effective Number of Bits AIN = 100 MHz @ -0.5 dBFS 8.6 8.9 bits AIN = 248 MHz @ -0.5 dBFS 8.5 8.7 bits 8.5 bits AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS 8.4 AIN = 748 MHz @ -0.5 dBFS SINAD Signal-to-Noise Plus Distortion Ratio 53.6 55.5 dB AIN = 248 MHz @ -0.5 dBFS 52.9 53.9 dB 52.7 dB AIN = 498 MHz @ -0.5 dBFS 52.3 AIN = 748 MHz @ -0.5 dBFS Signal-to-Noise Ratio 51.7 dB 53.8 55.9 dB AIN = 248 MHz @ -0.5 dBFS 53.3 54.6 dB 53.8 dB AIN = 498 MHz @ -0.5 dBFS 52.7 AIN = 748 MHz @ -0.5 dBFS Total Harmonic Distortion -67 -66 dB -64 -62 dB -59 dB -63 AIN = 748 MHz @ -0.5 dBFS -62 dB -77 -80 dBc AIN = 248 MHz @ -0.5 dBFS -66 -66 dBc -64 dBc AIN = 498 MHz @ -0.5 dBFS -66 AIN = 748 MHz @ -0.5 dBFS Third Harmonic Distortion dBc -69 -67 dBc AIN = 248 MHz @ -0.5 dBFS -65 -70 dBc -62 dBc AIN = 498 MHz @ -0.5 dBFS -63 AIN = 748 MHz @ -0.5 dBFS Spurious-Free Dynamic Range dBc -70 AIN = 100 MHz @ -0.5 dBFS AIN = 373 MHz @ -0.5 dBFS SFDR dB AIN = 100 MHz @ -0.5 dBFS AIN = 373 MHz @ -0.5 dBFS 3rd Harm dB AIN = 248 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS Second Harmonic Distortion dB 52.1 AIN = 100 MHz @ -0.5 dBFS AIN = 373 MHz @ -0.5 dBFS 2nd Harm dB AIN = 100 MHz @ -0.5 dBFS AIN = 373 MHz @ -0.5 dBFS THD bits AIN = 100 MHz @ -0.5 dBFS AIN = 373 MHz @ -0.5 dBFS SNR bits 8.3 dBc -62 dBc AIN = 100 MHz @ -0.5 dBFS 59.3 67 dBc AIN = 248 MHz @ -0.5 dBFS 58.9 62 dBc 60 dBc AIN = 373 MHz @ -0.5 dBFS AIN = 498 MHz @ -0.5 dBFS AIN = 748 MHz @ -0.5 dBFS 19 57.4 dBc 59 dBc www.national.com ADC10D1000/1500 Symbol ADC10D1000/1500 TABLE 8. Analog Input/Output and Reference Characteristics Symbol Parameter Conditions ADC10D1000 ADC10D1500 Typ Typ Lim Lim Units (Limits) Analog Inputs VIN_FSR Analog Differential Input Full Scale Non-Extended Control Mode Range FSR Pin Low 540 mVP-P (min) 660 660 mVP-P (max) 720 720 mVP-P (min) 860 mVP-P (max) 540 600 FSR Pin High 600 790 790 860 Extended Control Mode CIN RIN FM(14:0) = 0000h 600 600 mVP-P FM(14:0) = 4000h (default) 790 790 mVP-P FM(14:0) = 7FFFh 980 980 mVP-P Analog Input Capacitance, Non-DES Mode (Note 10) Differential 0.02 0.02 pF Each input pin to ground 1.6 1.6 pF Analog Input Capacitance, DES Mode (Note 10) Differential 0.08 0.08 pF Each input pin to ground 2.2 2.2 pF Differential Input Resistance 100 96 104 100 93 (min) 107 (max) Common Mode Output VCMO Common Mode Output Voltage ICMO = 100 A TC_VCMO Common Mode Output Voltage Temperature Coefficient ICMO = 100 A VCMO_LVL VCMO input threshold to set DC-coupling Mode CL_VCMO Maximum VCMO Load Capacitance (Note 10) 1.25 1.15 1.35 1.25 1.15 V (min) 1.35 V (max) 38 38 ppm/C 0.63 0.63 V 80 80 pF Bandgap Reference VBG Bandgap Reference Output Voltage IBG = 100 A TC_VBG Bandgap Reference Voltage Temperature Coefficient IBG = 100 A CL_VBG Maximum Bandgap Reference load Capacitance (Note 10) www.national.com 1.25 1.15 1.35 32 1.15 V (min) 1.35 V (max) 32 80 20 1.25 ppm/C 80 pF Symbol Parameter Conditions Offset Match X-TALK ADC10D1000 ADC10D1500 Typ Typ Lim Lim Units (Limits) 2 2 LSB Positive Full-Scale Match Zero offset selected in Control Register 2 2 LSB Negative Full-Scale Match Zero offset selected in Control Register 2 2 LSB Phase Matching (I, Q) fIN = 1.0 GHz <1 <1 Degree Crosstalk from I-channel Aggressor = 867 MHz F.S. (Aggressor) to Q-channel (Victim) Victim = 100 MHz F.S. -70 -70 dB Crosstalk from Q-channel (Aggressor) to I-channel (Victim) -70 -70 dB Aggressor = 867 MHz F.S. Victim = 100 MHz F.S. TABLE 10. Sampling Clock Characteristics Symbol VIN_CLK CIN_CLK RIN_CLK Parameter Differential Sampling Clock Input Level (Note 11) Conditions ADC10D1000 ADC10D1500 Typ Typ Sine Wave Clock Differential Peak-to-Peak 0.6 Square Wave Clock Differential Peak-to-Peak 0.6 Sampling Clock Input Capacitance Differential (Note 10) Each input to ground Sampling Clock Differential Input Resistance 21 Lim 0.4 2.0 0.4 2.0 0.6 0.6 Lim Units (Limits) 0.4 VP-P (min) 2.0 VP-P (max) 0.4 VP-P (min) 2.0 VP-P (max) 0.1 0.1 pF 1 1 pF 100 100 www.national.com ADC10D1000/1500 TABLE 9. I-Channel to Q-Channel Characteristics ADC10D1000/1500 TABLE 11. Digital Control and Output Pin Characteristics Symbol Parameter Conditions ADC10D1000 ADC10D1500 Typ Typ Lim Lim Units (Limits) Digital Control Pins (DES, CalDly, CAL, PDI, PDQ, TPM, NDM, FSR, DDRPh, ECE, SCLK, SDI, SCS) VIH Logic High Input Voltage 0.7xVA 0.7xVA V (min) VIL Logic Low Input Voltage 0.3xVA 0.3xVA V (max) IIH Input Leakage Current; VIN = VA IIL Input Leakage Current; VIN = GND CIN_DIG Digital Control Pin Input Capacitance (Note 10) 0.02 0.02 A -0.02 -0.02 A SCS, SCLK, SDI -17 -17 A PDI, PDQ, ECE -38 -38 A Measured from each control pin to GND 1.5 1.5 pF FSR, CalDly, CAL, NDM, TPM, DDRPh, DES Digital Output Pins (Data, DCLKI, DCLKQ, ORI, ORQ) VOD LVDS Differential Output Voltage VBG = Floating, OVS = High 375 mVP-P (min) 750 750 mVP-P (max) 260 260 mVP-P (min) 560 mVP-P (max) 375 560 VBG = Floating, OVS = Low 560 400 400 560 VO DIFF Change in LVDS Output Swing Between Logic Levels VOS Output Offset Voltage VBG = VA, OVS = High 600 600 mVP-P VBG = VA, OVS = Low 440 440 mVP-P 1 1 mV VBG = Floating 0.8 0.8 V VBG = VA 1.2 1.2 V 1 1 mV 4 4 mA 100 100 VOS Output Offset Voltage Change Between Logic Levels IOS Output Short Circuit Current ZO Differential Output Impedance VOH Logic High Output Level CalRun, SDO IOH = -400 A (Note 11) 1.65 1.5 1.65 1.5 V VOL Logic Low Output Level CalRun, SDO IOL = 400 A (Note 11) 0.15 0.3 0.15 0.3 V VBG = Floating; D+ and D- connected to 0.8V Differential DCLK Reset Pins (DCLK_RST) VCMI_DRST DCLK_RST Common Mode Input Voltage VID_DRST Differential DCLK_RST Input Voltage RIN_DRST Differential DCLK_RST Input Resistance www.national.com (Note 10) 22 1.25 0.15 1.25 0.15 V VIN_CLK VIN_CLK VP-P 100 100 Symbol IA Parameter Analog Supply Current ADC10D1000 ADC10D1500 Typ Lim Typ PDI = PDQ = Low 895 985 1170 mA (max) PDI = Low; PDQ = High 510 645 mA PDI = High; PDQ = Low 510 645 mA 2 2 mA 1095 mA (max) Conditions Lim Units (Limits) 1:2 Demux Mode PDI = PDQ = High Non-Demux Mode (Note 12) PDI = PDQ = Low 895 PDI = Low; PDQ = High 510 600 mA PDI = High; PDQ = Low 510 600 mA 2 2 mA PDI = PDQ = High ITC Track-and-Hold and Clock Supply 1:2 Demux Mode Current PDI = PDQ = Low 425 mA (max) PDI = Low; PDQ = High 220 260 mA PDI = High; PDQ = Low 220 260 mA 1 1.5 mA 370 mA (max) PDI = PDQ = High 360 985 400 Non-Demux Mode (Note 12) PDI = PDQ = Low 360 PDI = Low; PDQ = High 220 225 mA PDI = High; PDQ = Low 220 225 mA 1 1.5 mA PDI = PDQ = High IDR Output Driver Supply Current 400 1:2 Demux Mode PDI = PDQ = Low 210 220 mA (max) PDI = Low; PDQ = High 115 120 mA PDI = High; PDQ = Low 115 120 mA PDI = PDQ = High 10 15 A 260 Non-Demux Mode (Note 12) IE Digital Encoder Supply Current PDI = PDQ = Low 135 125 mA (max) PDI = Low; PDQ = High 80 75 mA PDI = High; PDQ = Low 80 75 mA PDI = PDQ = High 10 15 A 170 1:2 Demux Mode PDI = PDQ = Low 60 100 mA (max) PDI = Low; PDQ = High 35 50 mA PDI = High; PDQ = Low 35 50 mA PDI = PDQ = High 10 70 A 100 Non-Demux Mode (Note 12) ITOTAL Total Supply Current PDI = PDQ = Low 68 65 mA (max) PDI = Low; PDQ = High 40 40 mA PDI = High; PDQ = Low 40 40 mA PDI = PDQ = High 10 70 A 1:2 Demux Mode PDI = PDQ = Low 1525 23 100 1745 1915 2092 mA (max) www.national.com ADC10D1000/1500 TABLE 12. Power Supply Characteristics ADC10D1000/1500 Symbol PC ADC10D1000 ADC10D1500 Typ Lim Typ Lim Units (Limits) PDI = PDQ = Low 2.90 3.31 3.64 3.98 W (max) PDI = Low; PDQ = High 1.66 2.00 PDI = High; PDQ = Low 1.66 2.00 W 6 7 mW Parameter Power Consumption Conditions 1:2 Demux Mode PDI = PDQ = High W Non-Demux Mode (Note 12) PDI = PDQ = Low 2.77 3.14 W (max) PDI = Low; PDQ = High 1.61 1.68 W PDI = High; PDQ = Low 1.61 1.68 W 6 7 mW PDI = PDQ = High 3.14 TABLE 13. AC Electrical Characteristics Symbol Parameter Conditions ADC10D1000 ADC10D1500 Typ Typ Lim Lim Units (Limits) 1.5 GHz (min) Sampling Clock (CLK) fCLK (max) Maximum Sampling Clock Frequency fCLK (min) Minimum Sampling Clock Frequency Non-DES Mode 200 DES Mode 250 Sampling Clock Duty Cycle fCLK(min) fCLK fCLK(max) (Note 11) 50 1.0 200 MHz 250 20 80 50 MHz 20 % (min) 80 % (max) tCL Sampling Clock Low Time (Note 10) 500 200 333 133 ps (min) tCH Sampling Clock High Time (Note 10) 500 200 333 133 ps (min) Data Clock (DCLKI, DCLKQ) DCLK Duty Cycle (Note 10) 50 45 55 50 tSR Setup Time DCLK_RST (Note 11) 45 45 tHR Hold Time DCLK_RST (Note 11) 45 45 tPWR Pulse Width DCLK_RST (Note 10) tSYNC_DLY DCLK Synchronization Delay 90 Mode (Note 10) 0 Mode (Note 10) 45 % (min) 55 % (max) ps ps 5 5 4 4 5 5 Sampling Clock Cycles (min) Sampling Clock Cycles tLHT Differential Low-to-High Transition 10%-to-90%, CL = 2.5 pF Time 220 220 ps tHLT Differential High-to-Low Transition 10%-to-90%, CL = 2.5 pF Time 220 220 ps tSU Data-to-DCLK Setup Time 90 Mode (Note 10) 850 545 ps tH DCLK-to-Data Hold Time 90 Mode (Note 10) 850 570 ps tOSK DCLK-to-Data Output Skew 50% of DCLK transition to 50% of Data transition (Note 10) 50 50 ps (max) Sampling CLK+ Rise to Acquisition of Data 1.1 1.1 ns 0.2 0.2 ps (rms) 2.4 2.4 ns Data Input-to-Output tAD Aperture Delay tAJ Aperture Jitter tOD Sampling Clock-to Data Output Delay (in addition to Latency) www.national.com 50% of Sampling Clock transition to 50% of Data transition 24 tLAT Parameter Latency in 1:2 Demux Non-DES Mode (Note 10) Conditions ADC10D1000 ADC10D1500 Typ Typ tWU Lim DI, DQ Outputs 34 34 DId, DQd Outputs 35 35 Latency in 1:4 Demux DES Mode DI Outputs (Note 10) DQ Outputs tORR Lim 34 34 34.5 34.5 DId Outputs 35 35 DQd Outputs 35.5 35.5 Latency in Non-Demux Non-DES DI Outputs Mode (Note 10) DQ Outputs 34 34 34 34 Latency in Non-Demux DES Mode DI Outputs (Note 10) DQ Outputs 34 34 34.5 34.5 Over Range Recovery Time Wake-Up Time (PDI/PDQ low to Rated Accuracy Conversion) Differential VIN step from 1.2V to 0V to accurate conversion Non-DES Mode (Note 10) Units (Limits) Sampling Clock Cycles 1 1 Sampling Clock Cycle 500 500 ns DES Mode (Note 10) 1 1 s (Note 10) 15 Serial Port Interface fSCLK Serial Clock Frequency 15 MHz Serial Clock Low Time 30 30 ns (min) Serial Clock High Time 30 30 ns (min) tSSU Serial Data-to-Serial Clock Rising (Note 10) Setup Time 2.5 2.5 ns (min) tSH Serial Data-to-Serial Clock Rising (Note 10) Hold Time 1 1 ns (min) tSCS SCS-to-Serial Clock Rising Setup Time 2.5 2.5 ns tHCS SCS-to-Serial Clock Falling Hold Time 1.5 1.5 ns tBSU Bus turn-around time 10 10 ns 2.4*107 2.4*107 2.3*107 2.3*107 Sampling Clock Cycles CMS(1:0) = 00b 0.8*107 0.8*107 CMS(1:0) = 01b 1.5*107 1.5*107 CMS(1:0) = 10b (ECM default) 2.4*107 2.4*107 Calibration tCAL Calibration Cycle Time Non-ECM ECM CSS = 0b ECM; CSS = 1b tCAL_L tCAL_H tCalDly CAL Pin Low Time CAL Pin High Time Calibration delay determined by CalDly Pin (Note 10) Sampling Clock Cycles (Note 10) 1280 1280 Clock Cycles (min) 1280 1280 Clock Cycles (min) CalDly = Low 224 224 CalDly = High 230 230 (Note 10) Clock Cycles (max) Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. There is no guarantee of operation at the Absolute Maximum Ratings. Operating Ratings indicate conditions for which the device is functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test conditions. Note 2: All voltages are measured with respect to GND = GNDTC = GNDDR = GNDE = 0V, unless otherwise specified. Note 3: When the input voltage at any pin exceeds the power supply limits, i.e. less than GND or greater than VA, the current at that pin should be limited to 50 mA. In addition, over-voltage at a pin must adhere to the maximum voltage limits. Simultaneous over-voltage at multiple pins requires adherence to the maximum 25 www.national.com ADC10D1000/1500 Symbol ADC10D1000/1500 package power dissipation limits. These dissipation limits are calculated using JEDEC JESD51-7 thermal model. Higher dissipation may be possible based on specific customer thermal situation and specified package thermal resistances from junction to case. Note 4: Human body model is 100 pF capacitor discharged through a 1.5 k resistor. Machine model is 220 pF discharged through 0. Charged device model simulates a pin slowly acquiring charge (such as from a device sliding down the feeder in an automated assembler) then rapidly being discharged. Note 5: Reflow temperature profiles are different for lead-free and non-lead-free packages. Note 6: The analog inputs, labeled "I/O", are protected as shown below. Input voltage magnitudes beyond the Absolute Maximum Ratings may damage this device. 30066304 Note 7: To guarantee accuracy, it is required that VA, VTC, VE and VDR be well-bypassed. Each supply pin must be decoupled with separate bypass capacitors. Note 8: Typical figures are at TA = 25C, and represent most likely parametric norms. Test limits are guaranteed to National's AOQL (Average Outgoing Quality Level). Note 9: Calculation of Full-Scale Error for this device assumes that the actual reference voltage is exactly its nominal value. Full-Scale Error for this device, therefore, is a combination of Full-Scale Error and Reference Voltage Error. See Figure 4. For relationship between Gain Error and Full-Scale Error, see Specification Definitions for Gain Error. Note 10: This parameter is guaranteed by design and is not tested in production. Note 11: This parameter is guaranteed by design and/or characterization and is not tested in production. Note 12: The maximum clock frequency for Non-Demux Mode is tested up to 1.0 GHz for both the ADC10D1000 and the ADC10D1500 and guaranteed by design and characterization up to 1.5 GHz for the ADC10D1500. www.national.com 26 ADC10D1000/1500 12.0 Specification Definitions APERTURE (SAMPLING) DELAY is the amount of delay, measured from the sampling edge of the CLK input, after which the signal present at the input pin is sampled inside the device. APERTURE JITTER (tAJ) is the variation in aperture delay from sample-to-sample. Aperture jitter can be effectively considered as noise at the input. CODE ERROR RATE (CER) is the probability of error and is defined as the probable number of word errors on the ADC output per unit of time divided by the number of words seen in that amount of time. A CER of 10-18 corresponds to a statistical error in one word about every 31.7 years. CLOCK DUTY CYCLE is the ratio of the time that the clock waveform is at a logic high to the total time of one clock period. DIFFERENTIAL NON-LINEARITY (DNL) is the measure of the maximum deviation from the ideal step size of 1 LSB. It is measured at the relevant sample rate, fCLK, with fIN = 1MHz sine wave. EFFECTIVE NUMBER OF BITS (ENOB, or EFFECTIVE BITS) is another method of specifying Signal-to-Noise and Distortion Ratio, or SINAD. ENOB is defined as (SINAD - 1.76) / 6.02 and states that the converter is equivalent to a perfect ADC of this many (ENOB) number of bits. FULL POWER BANDWIDTH (FPBW) is a measure of the frequency at which the reconstructed output fundamental drops to 3 dB below its low frequency value for a full-scale input. GAIN ERROR is the deviation from the ideal slope of the transfer function. It can be calculated from Offset and FullScale Errors. The Positive Gain Error is the Offset Error minus the Positive Full-Scale Error. The Negative Gain Error is the Negative Full-Scale Error minus the Offset Error. The Gain Error is the Negative Full-Scale Error minus the Positive FullScale Error; it is also equal to the Positive Gain Error plus the Negative Gain Error. INTEGRAL NON-LINEARITY (INL) is a measure of worst case deviation of the ADC transfer function from an ideal straight line drawn through the ADC transfer function. The deviation of any given code from this straight line is measured from the center of that code value step. The best fit method is used. LSB (LEAST SIGNIFICANT BIT) is the bit that has the smallest value or weight of all bits. This value is 30066346 FIGURE 3. LVDS Output Signal Levels LVDS OUTPUT OFFSET VOLTAGE (VOS) is the midpoint between the D+ and D- pins output voltage with respect to ground; i.e., [(VD+) +( VD-)]/2. See Figure 3. MISSING CODES are those output codes that are skipped and will never appear at the ADC outputs. These codes cannot be reached with any input value. MSB (MOST SIGNIFICANT BIT) is the bit that has the largest value or weight. Its value is one half of full scale. NEGATIVE FULL-SCALE ERROR (NFSE) is a measure of how far the first code transition is from the ideal 1/2 LSB above a differential -VIN/2 with the FSR pin low. For the ADC10D1000/1500 the reference voltage is assumed to be ideal, so this error is a combination of full-scale error and reference voltage error. NOISE POWER RATIO (NPR) is the ratio of the sum of the power inside the notched bins to the sum of the power in an equal number of bins outside the notch, expressed in dB. NPR is similar to, but more complete than intermodulation distortion measurements. OFFSET ERROR (VOFF) is a measure of how far the midscale point is from the ideal zero voltage differential input. Offset Error = Actual Input causing average of 8k samples to result in an average code of 511.5. OUTPUT DELAY (tOD) is the time delay (in addition to Latency) after the rising edge of CLK+ before the data update is present at the output pins. OVER-RANGE RECOVERY TIME is the time required after the differential input voltages goes from 1.2V to 0V for the converter to recover and make a conversion with its rated accuracy. PIPELINE DELAY (LATENCY) is the number of input clock cycles between initiation of conversion and when that data is presented to the output driver stage. The data lags the conversion by the Latency plus the tOD. POSITIVE FULL-SCALE ERROR (PFSE) is a measure of how far the last code transition is from the ideal 1-1/2 LSB below a differential +VIN/2. For the ADC10D1000/1500 the reference voltage is assumed to be ideal, so this error is a combination of full-scale error and reference voltage error. SIGNAL TO NOISE RATIO (SNR) is the ratio, expressed in dB, of the rms value of the fundamental for a single-tone to the rms value of the sum of all other spectral components below one-half the sampling frequency, not including harmonics or DC. SIGNAL TO NOISE PLUS DISTORTION (S/(N+D) or SINAD) is the ratio, expressed in dB, of the rms value of the fundamental for a single-tone to the rms value of all of the other spectral components below half the input clock frequency, including harmonics but excluding DC. VFS / 2N where VFS is the differential full-scale amplitude VIN_FSR as set by the FSR input and "N" is the ADC resolution in bits, which is 10 for the ADC10D1000/1500. LOW VOLTAGE DIFFERENTIAL SIGNALING (LVDS) DIFFERENTIAL OUTPUT VOLTAGE (VID and VOD) is two times the absolute value of the difference between the VD+ and VD- signals; each signal measured with respect to Ground. VOD peak is VOD,P= (VD+ - VD-) and VOD peak-to-peak is VOD,P-P= 2*(VD+ - VD-); for this product, the VOD is measured peak-to-peak. 27 www.national.com ADC10D1000/1500 SPURIOUS-FREE DYNAMIC RANGE (SFDR) is the difference, expressed in dB, between the rms values of the input signal at the output and the peak spurious signal, where a spurious signal is any signal present in the output spectrum that is not present at the input, excluding DC. where Af1 is the RMS power of the fundamental (output) frequency and Af2 through Af10 are the RMS power of the first 9 harmonic frequencies in the output spectrum. - Second Harmonic Distortion (2nd Harm) is the difference, expressed in dB, between the RMS power in the input frequency seen at the output and the power in its 2nd harmonic level at the output. - Third Harmonic Distortion (3rd Harm) is the difference expressed in dB between the RMS power in the input frequency seen at the output and the power in its 3rd harmonic level at the output. JA is the thermal resistance between the junction to ambient. JC1 represents the thermal resistance between the die and the exposed metal area on the top of the HSBGA package. JC2 represents the thermal resistance between the die and the center group of balls on the bottom of the HSBGA package. TOTAL HARMONIC DISTORTION (THD) is the ratio expressed in dB, of the rms total of the first nine harmonic levels at the output to the level of the fundamental at the output. THD is calculated as www.national.com 28 ADC10D1000/1500 13.0 Transfer Characteristic 30066322 FIGURE 4. Input / Output Transfer Characteristic 29 www.national.com ADC10D1000/1500 14.0 Timing Diagrams 30066359 FIGURE 5. Clocking in 1:2 Demux Non-DES Mode* 30066360 FIGURE 6. Clocking in Non-Demux Non-DES Mode* www.national.com 30 ADC10D1000/1500 30066399 FIGURE 7. Clocking in 1:4 Demux DES Mode* 30066396 FIGURE 8. Clocking in Non-Demux Mode DES Mode* * The timing for these figures is shown for the one input only (I or Q). However, both I- and Q-inputs may be used. For this case, the I-channel functions precisely the same as the Q-channel, with VinI, DCLKI, DId and DI instead of VinQ, DCLKQ, DQd and DQ. Both I- and Q-channel use the same CLK. 31 www.national.com ADC10D1000/1500 30066320 FIGURE 9. Data Clock Reset Timing (Demux Mode) 30066325 FIGURE 10. Power-on and On-Command Calibration Timing 30066319 FIGURE 11. Serial Interface Timing www.national.com 32 VA = VDR = VTC = VE = 1.9V, fCLK = 1.0/1.5 GHz, fIN = 498/748 MHz, TA= 25C, I-channel, 1:2 Demux Non-DES Mode (1:1 Demux Non-DES Mode has similar performance), unless otherwise stated. For NPR plots, notch width = 5%, fc = 325 MHz. INL vs. CODE (ADC10D1000) INL vs. CODE (ADC10D1500) 30066338 30066349 INL vs. TEMPERATURE (ADC10D1000) INL vs. TEMPERATURE (ADC10D1500) 30066340 30066350 DNL vs. CODE (ADC10D1000) DNL vs. CODE (ADC10D1500) 30066339 30066351 33 www.national.com ADC10D1000/1500 15.0 Typical Performance Plots ADC10D1000/1500 DNL vs. TEMPERATURE (ADC10D1000) DNL vs. TEMPERATURE (ADC10D1500) 30066341 30066352 ENOB vs. TEMPERATURE (ADC10D1000) ENOB vs. TEMPERATURE (ADC10D1500) 30066376 30066354 ENOB vs. SUPPLY VOLTAGE (ADC10D1000) ENOB vs. SUPPLY VOLTAGE (ADC10D1500) 30066377 www.national.com 30066355 34 ENOB vs. CLOCK FREQUENCY (ADC10D1500) 30066378 30066356 ENOB vs. INPUT FREQUENCY (ADC10D1000) ENOB vs. INPUT FREQUENCY (ADC10D1500) 30066379 30066357 ENOB vs. VCMI (ADC10D1000) ENOB vs. VCMI (ADC10D1500) 30066342 30066358 35 www.national.com ADC10D1000/1500 ENOB vs. CLOCK FREQUENCY (ADC10D1000) ADC10D1000/1500 SNR vs. TEMPERATURE (ADC10D1000) SNR vs. TEMPERATURE (ADC10D1500) 30066368 30066311 SNR vs. SUPPLY VOLTAGE (ADC10D1000) SNR vs. SUPPLY VOLTAGE (ADC10D1500) 30066369 30066315 SNR vs. CLOCK FREQUENCY (ADC10D1000) SNR vs. CLOCK FREQUENCY (ADC10D1500) 30066370 www.national.com 30066316 36 SNR vs. INPUT FREQUENCY (ADC10D1500) 30066371 30066317 THD vs. TEMPERATURE (ADC10D1000) THD vs. TEMPERATURE (ADC10D1500) 30066372 30066318 THD vs. SUPPLY VOLTAGE (ADC10D1000) THD vs. SUPPLY VOLTAGE (ADC10D1500) 30066373 30066321 37 www.national.com ADC10D1000/1500 SNR vs. INPUT FREQUENCY (ADC10D1000) ADC10D1000/1500 THD vs. CLOCK FREQUENCY (ADC10D1000) THD vs. CLOCK FREQUENCY (ADC10D1500) 30066374 30066395 THD vs. INPUT FREQUENCY (ADC10D1000) THD vs. INPUT FREQUENCY (ADC10D1500) 30066375 30066323 SFDR vs. TEMPERATURE (ADC10D1000) SFDR vs. TEMPERATURE (ADC10D1500) 30066385 www.national.com 30066324 38 SFDR vs. SUPPLY VOLTAGE (ADC10D1500) 30066384 30066328 SFDR vs. CLOCK FREQUENCY (ADC10D1000) SFDR vs. CLOCK FREQUENCY (ADC10D1500) 30066382 30066361 SFDR vs. INPUT FREQUENCY (ADC10D1000) SFDR vs. INPUT FREQUENCY (ADC10D1500) 30066383 30066362 39 www.national.com ADC10D1000/1500 SFDR vs. SUPPLY VOLTAGE (ADC10D1000) ADC10D1000/1500 SPECTRAL RESPONSE AT FIN = 248 MHz (ADC10D1000) SPECTRAL RESPONSE AT FIN = 373 MHz (ADC10D1500) 30066387 30066367 SPECTRAL RESPONSE AT FIN = 498 MHz (ADC10D1000) SPECTRAL RESPONSE AT FIN = 748 MHz (ADC10D1500) 30066388 30066380 CROSSTALK vs. SOURCE FREQUENCY (ADC10D1000) CROSSTALK vs. SOURCE FREQUENCY (ADC10D1500) 30066363 www.national.com 30066386 40 0 0 -3 -3 SIGNAL GAIN (dB) SIGNAL GAIN (dB) FULL POWER BANDWIDTH (ADC10D1500) -6 -9 -12 0 1000 2000 INPUT FREQUENCY (MHz) -9 -12 NON-DES MODE DES MODE DESIQ MODE -15 -6 NON-DES MODE DES MODE DESIQ MODE -15 3000 0 1000 2000 INPUT FREQUENCY (MHz) 300663100 3000 300663100 POWER CONSUMPTION vs. CLOCK FREQUENCY (ADC10D1000) POWER CONSUMPTION vs. CLOCK FREQUENCY (ADC10D1500) 30066381 30066391 NPR vs. RMS NOISE LOADING LEVEL (ADC10D1000) NPR vs. FC,NOTCH (ADC10D1000) 30066331 30066332 41 www.national.com ADC10D1000/1500 FULL POWER BANDWIDTH (ADC10D1000) ADC10D1000/1500 NPR SPECTRAL RESPONSE (ADC10D1000) 30066333 www.national.com 42 The ADC10D1000/1500 is a versatile A/D converter with an innovative architecture which permits very high speed operation. The controls available ease the application of the device to circuit solutions. Optimum performance requires adherence to the provisions discussed here and in the Applications Information Section. This section covers an overview, a description of control modes (Extended Control Mode and Non-Extended Control Mode), and features. TABLE 14. Non-ECM Pin Summary Pin Name Logic-Low Logic-High Floating Dedicated Control Pins 16.1 OVERVIEW The ADC10D1000/1500 uses a calibrated folding and interpolating architecture that achieves a high 9.1/9.0 Effective Number of Bits (ENOB). The use of folding amplifiers greatly reduces the number of comparators and power consumption. Interpolation reduces the number of front-end amplifiers required, minimizing the load on the input signal and further reducing power requirements. In addition to correcting other non-idealities, on-chip calibration reduces the INL bow often seen with folding architectures. The result is an extremely fast, high performance, low power converter. The analog input signal (which is within the converter's input voltage range) is digitized to ten bits at speeds of 200/200 MSPS to 1.0/1.5 GSPS, typical. Differential input voltages below negative full-scale will cause the output word to consist of all zeroes. Differential input voltages above positive fullscale will cause the output word to consist of all ones. Either of these conditions at the I- or Q-input will cause the Out-ofRange I-channel or Q-channel output (ORI or ORQ), respectively, to output a logic-high signal. In ECM, an expanded feature set is available via the Serial Interface. The ADC10D1000/1500 builds upon previous architectures, introducing a new AutoSync feature for multi-chip synchronization and increasing to 15-bit for gain and 12-bit plus sign for offset the independent programmable adjustment for each channel. Each channel has a selectable output demultiplexer which feeds two LVDS buses. If the 1:2 Demux Mode is selected, the output data rate is reduced to half the input sample rate on each bus. When Non-Demux Mode is selected, the output data rate on each channel is at the same rate as the input sample clock and only one 10-bit bus per channel is active. DES Non-DES Mode DES Mode Not valid NDM Demux Mode Non-Demux Mode Not valid DDRPh 0 Mode 90 Mode Not valid CAL See Section 16.2.1.4 Calibration Pin (CAL) Not valid CalDly Shorter delay Longer delay Not valid PDI I-channel active Power Down I-channel Power Down I-channel PDQ Q-channel active Power Down Q-channel Power Down Q-channel TPM Non-Test Pattern Mode Test Pattern Mode Not valid FSR Lower FS input Range Higher FS input Range Not valid Dual-purpose Control Pins VCMO AC-coupled operation Not allowed DC-coupled operation VBG Not allowed Higher LVDS commonmode voltage Lower LVDS commonmode voltage 16.2.1.1 Dual Edge Sampling Pin (DES) The Dual Edge Sampling (DES) Pin selects whether the ADC10D1000/1500 is in DES Mode (logic-high) or Non-DES Mode (logic-low). DES Mode means that a single input is sampled by both I- and Q-channels in a time-interleaved manner and the other input is deactivated. One of the ADCs samples the input signal on the rising sampling clock edge (duty cycle corrected); the other ADC samples the input signal on the falling sampling clock edge (duty cycle corrected). In Non-ECM, only the I-input may be used for DES Mode, a.k.a. "DESI Mode". In ECM, the Q-input may be selected via the DEQ Bit (Addr: 0h, Bit: 6), a.k.a. "DESQ Mode". In ECM, both the I- and Q-channel inputs may be selected, a.k.a. "DESIQ Mode". To use this feature in ECM, use the DES bit in the Configuration Register (Addr: 0h; Bit: 7). See Section 16.3.1.4 DES/ Non-DES Mode for more information. 16.2 CONTROL MODES The ADC10D1000/1500 may be operated in one of two control modes: Non-extended Control Mode (Non-ECM) or Extended Control Mode (ECM). In the simpler Non-ECM (also sometimes referred to as Pin Control Mode), the user affects available configuration and control of the device through the control pins. The ECM provides additional configuration and control options through a serial interface and a set of 16 registers, most of which are available to the customer. 16.2.1.2 Non-Demultiplexed Mode Pin (NDM) The Non-Demultiplexed Mode (NDM) Pin selects whether the ADC10D1000/1500 is in Demux Mode (logic-low) or Non-Demux Mode (logic-high). In Non-Demux Mode, the data from the input is produced at the sampled rate at a single 10-bit output bus. In Demux Mode, the data from the input is produced at half the sampled rate at twice the number of output buses. For Non-DES Mode, each I- or Q-channel will produce its data on one or two buses for Non-Demux or Demux Mode, respectively. For DES Mode, the Q-channel will produce its data on two or four buses for Non-Demux or Demux Mode, respectively. 16.2.1 Non-Extended Control Mode In Non-extended Control Mode (Non-ECM), the Serial Interface is not active and all available functions are controlled via various pin settings. Non-ECM is selected by setting the ECE Pin to logic-high. Note that, for the control pins, "logichigh" and "logic-low" refer to VA and GND, respectively. Nine dedicated control pins provide a wide range of control for the ADC10D1000/1500 and facilitate its operation. These control pins provide DES Mode selection, Demux Mode selection, DDR Phase selection, execute Calibration, Calibration Delay setting, Power Down I-channel, Power Down Q-channel, Test Pattern Mode selection, and Full-Scale Input Range selection. In addition to this, two dual-purpose control pins provide 43 www.national.com ADC10D1000/1500 for AC/DC-coupled Mode selection and LVDS output common-mode voltage selection. See Table 14 for a summary. 16.0 Functional Description ADC10D1000/1500 This feature is pin-controlled only and remains active during both Non-ECM and ECM. See Section 16.3.2.5 Demux/Nondemux Mode for more information. to power-down the I-channel. See Section 16.3.4 Power Down for more information. 16.2.1.7 Power Down Q-channel Pin (PDQ) The Power Down Q-channel (PDQ) Pin selects whether the Q-channel is powered down (logic-high) or active (logic-low). This pin functions similarly to the PDI pin, except that it applies to the Q-channel. The PDI and PDQ pins function independently of each other to control whether each I- or Q-channel is powered down or active. This pin remains active in ECM. In ECM, either this pin or the PDQ bit (Addr: 0h; Bit: 10) in the Control Register may be used to power-down the Q-channel. See Section 16.3.4 Power Down for more information. 16.2.1.3 Dual Data Rate Phase Pin (DDRPh) The Dual Data Rate Phase (DDRPh) Pin selects whether the ADC10D1000/1500 is in 0 Mode (logic-low) or 90 Mode (logic-high). The Data is always produced in DDR Mode on the ADC10D1000/1500. The Data may transition either with the DCLK transition (0 Mode) or halfway between DCLK transitions (90 Mode). The DDRPh Pin selects 0 Mode or 90 Mode for both the I-channel: DI- and DId-to-DCLKI phase relationship and for the Q-channel: DQ- and DQd-to-DCLKQ phase relationship. To use this feature in ECM, use the DPS bit in the Configuration Register (Addr: 0h; Bit: 14). See Section 16.3.2.1 DDR Clock Phase for more information. 16.2.1.8 Test Pattern Mode Pin (TPM) The Test Pattern Mode (TPM) Pin selects whether the output of the ADC10D1000/1500 is a test pattern (logic-high) or the converted analog input (logic-low). The ADC10D1000/1500 can provide a test pattern at the four output buses independently of the input signal to aid in system debug. In TPM, the ADC is disengaged and a test pattern generator is connected to the outputs, including ORI and ORQ. SeeSection 16.3.2.6 Test Pattern Mode for more information. 16.2.1.4 Calibration Pin (CAL) The Calibration (CAL) Pin may be used to execute an oncommand calibration or to disable the power-on calibration. The effect of calibration is to maximize the dynamic performance. To initiate an on-command calibration via the CAL pin, bring the CAL pin high for a minimum of tCAL_H input clock cycles after it has been low for a minimum of tCAL_L input clock cycles. Holding the CAL pin high upon power-on will prevent execution of the power-on calibration. In ECM, this pin remains active and is logically OR'd with the CAL bit. To use this feature in ECM, use the CAL bit in the Configuration Register (Addr: 0h; Bit: 15). See Section 16.3.3 Calibration Feature for more information. 16.2.1.9 Full-Scale Input Range Pin (FSR) The Full-Scale Input Range (FSR) Pin selects whether the full-scale input range for both the I- and Q-channel is higher (logic-high) or lower (logic-low). The input full-scale range is specified as VIN_FSR in Table 8. In Non-ECM, the full-scale input range for each I- and Q-channel may not be set independently, but it is possible to do so in ECM. The device must be calibrated following a change in FSR to obtain optimal performance. To use this feature in ECM, use the Configuration Registers (Addr: 3h and Bh). See Section 16.3.1 Input Control and Adjust for more information. 16.2.1.5 Calibration Delay Pin (CalDly) The Calibration Delay (CalDly) Pin selects whether a shorter or longer delay time is present, after the application of power, until the start of the power-on calibration. The actual delay time is specified as tCalDly and may be found in Table 13. This feature is pin-controlled only and remains active in ECM. It is recommended to select the desired delay time prior to poweron and not dynamically alter this selection. See Section 16.3.3 Calibration Feature for more information. 16.2.1.10 AC/DC-Coupled Mode Pin (VCMO) The VCMO Pin serves a dual purpose. When functioning as an output, it provides the optimal common-mode voltage for the DC-coupled analog inputs. When functioning as an input, it selects whether the device is AC-coupled (logic-low) or DCcoupled (floating). This pin is always active, in both ECM and Non-ECM. 16.2.1.6 Power Down I-channel Pin (PDI) The Power Down I-channel (PDI) Pin selects whether the Ichannel is powered down (logic-high) or active (logic-low). The digital data output pins, DI and DId, (both positive and negative) are put into a high impedance state when the Ichannel is powered down. Upon return to the active state, the pipeline will contain meaningless information and must be flushed. The supply currents (typicals and limits) are available for the I-channel powered down or active and may be found in Table 12. The device should be recalibrated following a power-cycle of PDI (or PDQ). This pin remains active in ECM. In ECM, either this pin or the PDI bit (Addr: 0h; Bit: 11) in the Control Register may be used www.national.com 16.2.1.11 LVDS Output Common-mode Pin (VBG) The VBG Pin serves a dual purpose. When functioning as an output, it provides the bandgap reference. When functioning as an input, it selects whether the LVDS output commonmode voltage is higher (logic-high) or lower (floating). The LVDS output common-mode voltage is specified as V OS and may be found in Table 11. This pin is always active, in both ECM and Non-ECM. 44 16.2.2.1 The Serial Interface The ADC10D1000/1500 offers a Serial Interface that allows access to the sixteen control registers within the device. The Serial Interface is a generic 4-wire (optionally 3-wire) synchronous interface that is compatible with SPI type interfaces that are used on many micro-controllers and DSP controllers. Each serial interface access cycle is exactly 24 bits long. A register-read or register-write can be accomplished in one cycle. The signals are defined in such a way that the user can opt to simply join SDI and SDO signals in his system to accomplish a single, bidirectional SDI/O signal. A summary of the pins for this interface may be found in Table 15. See Figure 11 for the timing diagram and Table 13 for timing specification details. Control register contents are retained when the device is put into power-down mode. TABLE 16. Command and Data Field Definitions TABLE 15. Serial Interface Pins Pin Name C4 SCS (Serial Chip Select bar) C5 SCLK (Serial Clock) B4 SDI (Serial Data In) A3 SDO (Serial Data Out) SCS: Each assertion (logic-low) of this signal starts a new register access, i.e. the SDI command field must be ready on the following SCLK rising edge. The user is required to deassert this signal after the 24th clock. If the SCS is deasserted before the 24th clock, no data read/write will occur. For a read operation, if the SCS is asserted longer than 24 Bit No. Name Comments 1 Read/Write (R/W) 1b indicates a read operation 0b indicates a write operation 2-3 Reserved Bits must be set to 10b 4-7 A<3:0> 16 registers may be addressed. The order is MSB first 8 X This is a "don't care" bit 9-24 D<15:0> Data written to or read from addressed register The serial data protocol is shown for a read and write operation in Figure 12 and Figure 13, respectively. 30066392 FIGURE 12. Serial Data Protocol - Read Operation 45 www.national.com ADC10D1000/1500 clocks, the SDO output will hold the D0 bit until SCS is deasserted. For a write operation, if the SCS is asserted longer than 24 clocks, data write will occur normally through the SDI input upon the 24th clock. Setup and hold times, tSCS and tHCS, with respect to the SCLK must be observed. SCS must be toggled in between register access cycles. SCLK: This signal is used to register the input data (SDI) on the rising edge; and to source the output data (SDO) on the falling edge. The user may disable the clock and hold it at logic-low. There is no minimum frequency requirement for SCLK; see fSCLK in Table 13 for more details. SDI: Each register access requires a specific 24-bit pattern at this input, consisting of a command field and a data field. When in read mode, the data field is high impedance in case the bidirectional SDI/O option is used. Setup and hold times, tSH and tSSU, with respect to the SCLK must be observed. SDO: This output is normally tri-stated and is driven only when SCS is asserted, the first 8 bits of command data have been received and it is a READ operation. The data is shifted out, MSB first, starting with the 8th clock's falling edge. At the end of the access, when SCS is de-asserted, this output is tristated once again. If an invalid address is accessed, the data sourced will consist of all zeroes. If it is a read operation, there will be a bus turnaround time, tBSU, from when the last bit of the command field was read in until the first bit of the data field is written out. Table 16 shows the Serial Interface bit definitions. 16.2.2 Extended Control Mode In Extended Control Mode (ECM), most functions are controlled via the Serial Interface. In addition to this, several of the control pins remain active. See Table 17 for details. ECM is selected by setting the ECE Pin to logic-low. If the ECE Pin is set to logic-high (Non-ECM), then the registers are reset to their default values. So, a simple way to reset the registers is by toggling the ECE pin. Four pins on the ADC10D1000/1500 control the Serial Interface: SCS, SCLK, SDI and SDO. This section covers the Serial Interface. The Register Definitions are located at the end of the datasheet so that they are easy to find, see Section 18.0 Register Definitions. ADC10D1000/1500 30066393 FIGURE 13. Serial Data Protocol - Write Operation www.national.com 46 TABLE 17. Features and Modes Feature Control Pin Active in ECM Non-ECM ECM Default ECM State Input Control and Adjust AC/DC-coupled Mode Selection Selected via VCMO (Pin C2) Yes Not available N/A Input Full-scale Range Adjust Selected via FSR (Pin Y3) No Selected via the Config Reg (Addr: 3h and Bh) Mid FSR value Input Offset Adjust Setting Not available N/A Selected via the Config Reg (Addr: 2h and Ah) Offset = 0 mV LC Filter on Clock Not available N/A Selected via the Config Reg (Addr: Dh) LC Filter off DES/Non-DES Mode Selection Selected via DES (Pin V5) No Selected via the DES Bit (Addr: 0h; Bit: 7) Non-DES Mode Sampling Clock Phase Adjust Not available N/A Selected via the Config Reg (Addr: Ch and Dh) tAD adjust disabled VCMO Adjust Not available N/A Selected via the Config Reg (Addr: 1h) Default VCMO DDR Clock Phase Selection Selected via DDRPh (Pin W4) No Selected via the DPS Bit (Addr: 0h; Bit: 14) 0 Mode LVDS Differential Output Voltage Amplitude Selection Higher amplitude only N/A Selected via the OVS Bit (Addr: 0h; Bit: 13) Higher amplitude LVDS Common-Mode Output Voltage Amplitude Selection Selected via VBG (Pin B1) Yes Not available N/A Output Formatting Selection Offset Binary only N/A Selected via the 2SC Bit (Addr: 0h; Bit: 4) Offset Binary Test Pattern Mode at Output Selected via TPM (Pin A4) No Selected via the TPM Bit (Addr: 0h; Bit: 12) TPM disabled Demux/Non-Demux Mode Selection Selected via NDM (Pin A5) Yes Not available N/A AutoSync Not available N/A Selected via the Config Reg (Addr: Eh) Master Mode, RCOut1/2 disabled DCLK Reset Not available N/A Selected via the Config Reg DCLK Reset disabled (Addr: Eh) On-command Calibration Selected via CAL (Pin D6) Yes Selected via the CAL Bit (Addr: 0h; Bit: 15) N/A (CAL = 0) Power-on Calibration Delay Selection Selected via CalDly (Pin V4) Yes Not available N/A Calibration Adjust Not available N/A Selected via the Config Reg (Addr: 4h) tCAL Power down I-channel Selected via PDI (Pin U3) Yes Selected via the PDI Bit (Addr: 0h; Bit: 11) I-channel operational Power down Q-channel Selected via PDQ (Pin V3) Yes Selected via the PDQ Bit (Addr: 0h; Bit: 10) Q-channel operational Output Control and Adjust Calibration Power-Down "N/A" means "Not Applicable." 47 www.national.com ADC10D1000/1500 Table 17 is a summary of the features available, as well as details for the control mode chosen. 16.3 FEATURES The ADC10D1000/1500 offers many features to make the device convenient to use in a wide variety of applications. ADC10D1000/1500 each channel is being driven, which reduces routing losses (increases bandwidth). In the DES Mode, the outputs must be carefully interleaved in order to reconstruct the sampled signal. If the device is programmed into the 1:4 Demux DES Mode, the data is effectively demultiplexed by 1:4. If the sampling clock is 1.0/1.5 GHz, the effective sampling rate is doubled to 2.0/3.0 GSPS and each of the 4 output buses has an output rate of 500 MSPS. All data is available in parallel. To properly reconstruct the sampled waveform, the four bytes of parallel data that are output with each DCLK must be correctly interleaved. The sampling order is as follows, from the earliest to the latest: DQd, DId, DQ, DI. See Figure 7. If the device is programmed into the Non-Demux DES Mode, two bytes of parallel data are output with each edge of the DCLK in the following sampling order, from the earliest to the latest: DQ, DI. See Figure 8. The performance of the ADC10D1000/1500 in DES Mode depends on how well the two channels are interleaved, i.e. that the clock samples either channel with precisely a 50% duty-cycle, each channel has the same offset (nominally code 511/512), and each channel has the same full-scale range. The ADC10D1000/1500 includes an automatic clock phase background adjustment in DES Mode to automatically and continuously adjust the clock phase of the I- and Q-channels, which also removes the need to adjust the clock phase setting manually. A difference exists in the typical offset between the I- and Q-channels, which can be removed via the offset adjust feature in ECM, to optimize DES Mode performance. If possible, it is recommended to use the Q-input for better DES Mode performance with no offset adjustment required. To adjust the I- or Q-channel offset, measure a histogram of the digital data and adjust the offset via the Control Register until the histogram is centered at code 511/512. Similarly, the fullscale range of each channel may be adjusted for optimal performance. 16.3.1 Input Control and Adjust There are several features and configurations for the input of the ADC10D1000/1500 so that it may be used in many different applications. This section covers AC/DC-coupled Mode, input full-scale range adjust, input offset adjust, DES/ Non-DES Mode, sampling clock phase adjust, an LC filter on the sampling clock, and VCMO Adjust. 16.3.1.1 AC/DC-coupled Mode The analog inputs may be AC or DC-coupled. See Section 16.2.1.10 AC/DC-Coupled Mode Pin (VCMO) for information on how to select the desired mode and Section 17.1.8 DC-coupled Input Signals and Section 17.1.7 AC-coupled Input Signals for applications information. 16.3.1.2 Input Full-Scale Range Adjust The input full-scale range for the ADC10D1000/1500 may be adjusted via Non-ECM or ECM. In Non-ECM, a control pin selects a higher or lower value; see Section 16.2.1.9 FullScale Input Range Pin (FSR). In ECM, the input full-scale range may be adjusted with 15-bits of precision. See VIN_FSR in Table 8 for electrical specification details. Note that the higher and lower full-scale input range settings in NonECM correspond to the mid and min full-scale input range settings in ECM. It is necessary to execute an on-command calibration following a change of the input full-scale range. See Section 18.0 Register Definitions for information about the registers. 16.3.1.3 Input Offset Adjust The input offset adjust for the ADC10D1000/1500 may be adjusted with 12-bits of precision plus sign via ECM. See Section 18.0 Register Definitions for information about the registers. 16.3.1.4 DES/Non-DES Mode The ADC10D1000/1500 can operate in Dual-Edge Sampling (DES) or Non-DES Mode. The DES Mode allows for one of the ADC10D1000/1500's inputs to be sampled by both channels' ADCs. One ADC samples the input on the rising edge of the sampling clock and the other ADC samples the same input on the falling edge of the sampling clock. A single input is thus sampled twice per clock cycle, resulting in an overall sample rate of twice the sampling clock frequency, e.g. 2.0/3.0 GSPS with a 1.0/1.5 GHz sampling clock. See Section 16.2.1.1 Dual Edge Sampling Pin (DES) for information on how to select the desired mode. Since DES Mode uses both I- and Q-channels to process the input signal, both channels must be powered up for the DES Mode to function properly. In Non-ECM, only the I-input may be used for the DES Mode input. In ECM, either the I- or Q-input may be selected by first using the DES bit (Addr: 0h, Bit 7) to select the DES Mode. The DEQ Bit (Addr: 0h, Bit: 6) is used to select the Q-input, but the I-input is used by default. Also, both I- and Q-inputs may be driven externally, i.e. DESIQ Mode, by using the DIQ bit (Addr: 0h, Bit 5). See Section 17.1 THE ANALOG INPUTS for more information about how to drive the ADC in DES Mode. The DESIQ Mode results in the best bandwidth. In general, the bandwidth decreases from Non-DES Mode to DES Mode (specifically, DESI or DESQ) because both channels are sampling off the same input signal and non-ideal effects introduced by interleaving the two channels lower the bandwidth. Driving both I- and Q-channels externally (DESIQ Mode) results in better bandwidth for the DES Mode because www.national.com 16.3.1.5 Sampling Clock Phase Adjust The sampling clock (CLK) phase may be delayed internally to the ADC up to 825 ps in ECM. This feature is intended to help the system designer remove small imbalances in clock distribution traces at the board level when multiple ADCs are used, or to simplify complex system functions such as beam steering for phase array antennas. Additional delay in the clock path also creates additional jitter, so a clock jitter-cleaner is made available when using the sampling clock phase adjust, see Section 16.3.1.6 LC Filter on Sampling Clock. Nevertheless, because the sampling clock phase adjust delays all clocks, including the DCLKs and output data, the user is strongly advised to use the minimal amount of adjustment and verify the net benefit of this feature in his system before relying on it. 16.3.1.6 LC Filter on Sampling Clock A LC bandpass filter is available on the ADC10D1000/1500 sampling clock to clean jitter on the incoming clock. This feature is only available when the CLK phase adjust feature is also used. This feature was designed to minimize the dynamic performance degradation resulting from additional clock jitter as much as possible. It is available in ECM via the LCF (LC Filter) bits in the Control Register (Addr: Dh, Bits 7:0). If the clock phase adjust feature is enabled, the sampling clock passes through additional gate delay, which adds jitter to the clock signal. The LC filter helps to remove this additional jitter, so it is only available when the clock phase adjust feature is also enabled. To enable both features, use SA (Addr: Dh, Bit 8). The LCF bits are thermometer encoded and may 48 ADC10D1000/1500 be used to set a filter center frequency ranging from 0.8 GHz to 1.5 GHz; see Table 18. TABLE 18. LC Filter Code vs. fc LCF(7:0) LCF(7:0) fc (GHz) 0 0000 0000b 1.5 1 0000 0001b 1.4 2 0000 0011b 1.3 3 0000 0111b 1.2 4 0000 1111b 1.1 5 0001 1111b 1.0 6 0011 1111b 0.92 7 0111 1111b 0.85 8 1111 1111b 0.8 30066394 FIGURE 14. DDR DCLK-to-Data Phase Relationship 16.3.2.2 LVDS Output Differential Voltage The ADC10D1000/1500 is available with a selectable higher or lower LVDS output differential voltage. This parameter is VOD and may be found in Table 11. The desired voltage may be selected via the OVS Bit (Addr: 0h, Bit 13); see Section 18.0 Register Definitions for more information. The LC filter is a second-order bandpass filter, which has the following simulated bandwidth for a center frequency at 1GHz, see Table 19. TABLE 19. LC Filter Bandwidth vs. Level Bandwidth at [dB] -3 -6 -9 -12 Bandwidth [MHz] 135 235 360 525 16.3.2.3 LVDS Output Common-Mode Voltage The ADC10D1000/1500 is available with a selectable higher or lower LVDS output common-mode voltage. This parameter is VOS and may be found in Table 11. See Section 16.2.1.11 LVDS Output Common-mode Pin (VBG) for information on how to select the desired voltage. 16.3.1.7 VCMO Adjust The VCMO of the ADC10D1000/1500 is generated as a buffered version of the internal bandgap reference; see VCMO in Table 8. This pin provides an output voltage which is the optimal common-mode voltage for the input signal and should be used to set the common-mode voltage of the driving buffer. However, in order to accommodate larger signals at the analog inputs, the VCMO may be adjust to a lower value. From its typical default value, the VCMO may be lowered by approximately 200 mV via the Control Register 1h. See Section 18.0 Register Definitions for more information. Adjusting the VCMO away from its optimal value will also degrade the dynamic performance; see ENOB vs. VCMO in Section 15.0 Typical Performance Plots for a typical plot. The performance of the device, when using a VCMO other than the default value, is not guaranteed. 16.3.2.4 Output Formatting The formatting at the digital data outputs may be either offset binary or two's complement. The default formatting is offset binary, but two's complement may be selected via the 2SC Bit (Addr: 0h, Bit 4); see Section 18.0 Register Definitions for more information. 16.3.2.5 Demux/Non-demux Mode The ADC10D1000/1500 may be in one of two demultiplex modes: Demux Mode or Non-Demux Mode (also sometimes referred to as 1:1 Demux Mode). In Non-Demux Mode, the data from the input is simply output at the sampling rate at which it was sampled on one 10-bit bus. In Demux Mode, the data from the input is output at half the sampling rate, on twice the number of buses. See Figure 1. Demux/Non-Demux Mode may only be selected by the NDM pin; see Section 16.2.1.2 Non-Demultiplexed Mode Pin (NDM). In NonDES Mode, the output data from each channel may be demultiplexed by a factor of 1:2 (1:2 Demux Non-DES Mode) or not demultiplexed (Non-Demux Non-DES Mode). In DES Mode, the output data from both channels interleaved may be demultiplexed (1:4 Demux DES Mode) or not demultiplexed (Non-Demux DES Mode). 16.3.2 Output Control and Adjust There are several features and configurations for the output of the ADC10D1000/1500 so that it may be used in many different applications. This section covers DDR clock phase, LVDS output differential and common-mode voltage, output formatting, Demux/Non-demux Mode, and Test Pattern Mode. 16.3.2.1 DDR Clock Phase The ADC10D1000/1500 output data is always delivered in Double Data Rate (DDR). With DDR, the DCLK frequency is half the data rate and data is sent to the outputs on both edges of DCLK; see Figure 14. The DCLK-to-Data phase relationship may be either 0 or 90. For 0 Mode, the Data transitions on each edge of the DCLK. Any offset from this timing is tOSK; see Table 13 for details. For 90 Mode, the DCLK transitions in the middle of each Data cell. Setup and hold times for this transition, tSU and tH, may also be found in Table 13. The DCLK-to-Data phase relationship may be selected via the DDRPh Pin in Non-ECM (see Section 16.2.1.3 Dual Data Rate Phase Pin (DDRPh)) or the DPS bit in the Configuration Register (Addr: 0h; Bit: 14) in ECM. 16.3.2.6 Test Pattern Mode The ADC10D1000/1500 can provide a test pattern at the four output buses independently of the input signal to aid in system debug. In Test Pattern Mode, the ADC is disengaged and a test pattern generator is connected to the outputs, including ORI and ORQ. The test pattern output is the same in DES Mode or Non-DES Mode. Each port is given a unique 10-bit word, alternating between 1's and 0's. When the part is programmed into the Demux Mode, the test pattern's order is described in Table 20. If the I- or Q-channel is powered down, the test pattern will not be output for that channel. 49 www.national.com ADC10D1000/1500 TABLE 22. Calibration Pins TABLE 20. Test Pattern by Output Port in Demux Mode Time Qd Id Q I ORQ ORI Comments T0 000h 001h 002h 004h 0b 0b T1 3FFh 3FEh 3FDh 3FBh 1b 1b T2 000h 001h 002h 004h 0b 0b T3 3FFh 3FEh 3FDh 3FBh 1b 1b T4 000h 001h 002h 004h 0b 0b T5 000h 001h 002h 004h 0b 0b T6 3FFh 3FEh 3FDh 3FBh 1b 1b T7 000h 001h 002h 004h 0b 0b T8 3FFh 3FEh 3FDh 3FBh 1b 1b T9 000h 001h 002h 004h 0b 0b T10 000h 001h 002h 004h 0b 0b T11 3FFh 3FEh 3FDh 3FBh 1b 1b T12 000h 001h 002h 004h 0b 0b T13 ... ... ... ... ... ... Pattern Sequence n Pattern Sequence n+1 Pattern Sequence n+2 I Q ORI ORQ 001h 000h 0b 0b T1 001h 000h 0b 0b T2 3FEh 3FFh 1b 1b T3 3FEh 3FFh 1b 1b T4 001h 000h 0b 0b T5 3FEh 3FFh 1b 1b T6 001h 000h 0b 0b T7 3FEh 3FFh 1b 1b T8 3FEh 3FFh 1b 1b T9 3FEh 3FFh 1b 1b T10 001h 000h 0b 0b T11 001h 000h 0b 0b T12 3FEh 3FFh 1b 1b T13 3FEh 3FFh 1b 1b T14 ... ... ... ... D6 (Addr: 0h; Bit 15) CAL (Calibration) Initiate calibration V4 CalDly (Calibration Delay) Select calibration delay Addr: 4h Calibration Adjust Adjust calibration sequence and mode B5 CalRun (Calibration Running) Indicates while calibration is running Rtrim+/External resistor used to (Input termination calibrate analog and trim resistor) CLK inputs Rext+/(External Reference resistor) External resistor used to calibrate internal linearity 16.3.3.2 How to Execute a Calibration Calibration may be initiated by holding the CAL pin low for at least tCAL_L clock cycles, and then holding it high for at least another tCAL_H clock cycles, as defined in Table 13. The minimum tCAL_L and tCAL_H input clock cycle sequences are required to ensure that random noise does not cause a calibration to begin when it is not desired. The time taken by the calibration procedure is specified as tCAL. The CAL Pin is active in both ECM and Non-ECM. However, in ECM, the CAL Pin is logically OR'd with the CAL Bit, so both the pin and bit are required to be set low before executing another calibration via either pin or bit. Comments Pattern Sequence n 16.3.3.3 Power-on Calibration For standard operation, power-on calibration begins after a time delay following the application of power, as determined by the setting of the CalDly Pin and measured by tCalDly (see Table 13). This delay allows the power supply to come up and stabilize before the power-on calibration takes place. The best setting (short or long) of the CalDly Pin depends upon the settling time of the power supply. It is strongly recommended to set CalDly Pin (to either logichigh or logic-low) before powering the device on since this pin affects the power-on calibration timing. This may be accomplished by setting CalDly via an external 1k resistor connected to GND or VA. If the CalDly Pin is toggled while the device is powered-on, it can execute a calibration even though the CAL Pin/Bit remains logic-low. The power-on calibration will be not be performed if the CAL pin is logic-high at power-on. In this case, the calibration cycle will not begin until the on-command calibration conditions are met. The ADC10D1000/1500 will function with the CAL pin held high at power up, but no calibration will be done and performance will be impaired. If it is necessary to toggle the CalDly Pin during the system power up sequence, then the CAL Pin/Bit must be set to logichigh during the toggling and afterwards for 109 Sampling Clock cycles. This will prevent the power-on calibration, so an on-command calibration must be executed or the performance will be impaired. Pattern Sequence n+1 16.3.3 Calibration Feature The ADC10D1000/1500 calibration must be run to achieve specified performance. The calibration procedure is exactly the same regardless of how it was initiated or when it is run. Calibration trims the analog input differential termination resistors, the CLK input resistor, and sets internal bias currents which affect the linearity of the converter. This minimizes fullscale error, offset error, DNL and INL, resulting in maximizing the dynamic performance, as measured by: SNR, THD, SINAD (SNDR) and ENOB. 16.3.3.1 Calibration Control Pins and Bits Table 22 is a summary of the pins and bits used for calibration. See Section 8.0 Ball Descriptions and Equivalent Circuits for complete pin information and Figure 10 for the timing diagram. www.national.com Function C3/D3 TABLE 21. Test Pattern by Output Port in Non-Demux Mode T0 Name C1/D2 When the part is programmed into the Non-Demux Mode, the test pattern's order is described in Table 21. Time Pin/Bit 50 16.3.3.5 Calibration Adjust The calibration event itself may be adjusted, for sequence and mode. This feature can be used if a shorter calibration time than the default is required; see tCAL in Table 13. However, the performance of the device, when using a shorter calibration time than the default setting, is not guaranteed. The calibration sequence may be adjusted via CSS (Addr: 4h, Bit 14). The default setting of CSS = 1b executes both RIN and RIN_CLK Calibration (using Rtrim) and internal linearity Calibration (using Rext). Executing a calibration with CSS = 0b executes only the internal linearity Calibration. The first time that Calibration is executed, it must be with CSS = 1b to trim RIN and RIN_CLK. However, once the device is at its operating temperature and RIN has been trimmed at least one time, it will not drift significantly. To save time in subsequent calibrations, trimming RIN and RIN_CLK may be skipped, i.e. by setting CSS = 0b. The mode may be changed, to save calibration execution time for the internal linearity Calibration. See tCAL in Table 13. Adjusting CMS(1:0) will select three different pre-defined calibration times. A larger amount of time will calibrate each channel more closely to the ideal values, but choosing shorter times will not significantly impact the performance. The fourth setting, CMS(1:0) = 11b, is not available. 16.3.3.7 Calibration and Power-Down If PDI and PDQ are simultaneously asserted during a calibration cycle, the ADC10D1000/1500 will immediately power down. The calibration cycle will continue when either or both channels are powered back up, but the calibration will be compromised due to the incomplete settling of bias currents directly after power up. Therefore, a new calibration should be executed upon powering the ADC10D1000/1500 back up. In general, the ADC10D1000/1500 should be recalibrated when either or both channels are powered back up, or after one channel is powered down. For best results, this should be done after the device has stabilized to its operating temperature. 16.3.3.8 Calibration and the Digital Outputs During calibration, the digital outputs (including DI, DId, DQ, DQd and OR) are set logic-low, to reduce noise. The DCLK runs continuously during calibration. After the calibration is completed and the CalRun signal is logic-low, it takes an additional 60 Sampling Clock cycles before the output of the ADC10D1000/1500 is valid converted data from the analog inputs. This is the time it takes for the pipeline to flush, as well as for other internal processes. 16.3.3.6 Read/Write Calibration Settings When the ADC performs a calibration, the calibration constants are stored in an array which is accessible via the Calibration Values register (Addr: 5h). To save the time which it takes to execute a calibration, tCAL, or if re-using a previous calibration result, these values can be read from and written to the register at a later time. For example, if an application requires the same input impedance, RIN, this feature can be used to load a previously determined set of values. For the calibration values to be valid, the ADC must be operating under the same conditions, including temperature, at which the calibration values were originally read from the ADC. 16.3.4 Power Down On the ADC10D1000/1500, the I- and Q-channels may be powered down individually. This may be accomplished via the control pins, PDI and PDQ, or via ECM. In ECM, the PDI and PDQ pins are logically OR'd with the Control Register setting. See Section 16.2.1.6 Power Down I-channel Pin (PDI) andSection 16.2.1.7 Power Down Q-channel Pin (PDQ) for more information. 51 www.national.com ADC10D1000/1500 To read calibration values from the SPI, do the following: 1. Set ADC to desired operating conditions. 2. Set SSC (Addr: 4h, Bit 7) to 1. 3. Power down both I- and Q-channels. 4. Read exactly 184 times the Calibration Values register (Addr: 5h). The register values are R0, R1, R2... R183. The contents of R<183:0> should be stored. 5. Power up I- and Q-channels to original setting. 6. Set SSC (Addr: 4h, Bit 7) to 0. 7. Continue with normal operation. To write calibration values to the SPI, do the following: 1. Set ADC to operating conditions at which Calibration Values were previously read. 2. Set SSC (Addr: 4h, Bit 7) to 1. 3. Power down both I- and Q-channels. 4. Write exactly 184 times the Calibration Values register (Addr: 5h). The registers should be written with stored register values R0, R1... R183. 5. Make two additional dummy writes of 0000h. 6. Power up I- and Q-channels to original setting. 7. Set SSC (Addr: 4h, Bit 7) to 0. 8. Continue with normal operation. 16.3.3.4 On-command Calibration In addition to the power-on calibration, it is recommended to execute an on-command calibration whenever the settings or conditions to the device are altered significantly, in order to obtain optimal parametric performance. Some examples include: changing the FSR via either ECM or Non-ECM, powercycling either channel, and switching into or out of DES Mode. For best performance, it is also recommended that an oncommand calibration be run 20 seconds or more after application of power and whenever the operating temperature changes significantly, relative to the specific system performance requirements. Due to the nature of the calibration feature, it is recommended to avoid unnecessary activities on the device while the calibration is taking place. For example, do not read or write to the Serial Interface or use the DCLK Reset feature while calibrating the ADC. Doing so will impair the performance of the device until it is re-calibrated correctly. Also, it is recommended to not apply a strong narrow-band signal to the analog inputs during calibration because this may impair the accuracy of the calibration; broad spectrum noise is acceptable. ADC10D1000/1500 17.1.2 Driving the ADC in DES Mode The ADC10D1000/1500 can be configured as either a 2channel, 1.0/1.5 GSPS device (Non-DES Mode) or a 1-channel 2.0/3.0 GSPS device (DES Mode). When the device is configured in DES Mode, there is a choice for with which input to drive the single-channel ADC. These are the 3 options: DES - externally driving the I-channel input only. This is the default selection when the ADC is configured in DES Mode. It may also be referred to as "DESI" for added clarity. DESQ - externally driving the Q-channel input only. DESIQ - externally driving both the I- and Q-channel inputs. VinI+ and VinQ+ should be driven with the exact same signal. VinI- and VinQ- should be driven with the exact same signal, which is the differential complement to the one driving VinI+ and VinQ+. The input impedance for each I- and Q-input is 100 differential (or 50 single-ended), so the trace to each VinI+, VinI-, VinQ+, and VinQ- should always be 50 single-ended. If a single I- or Q-input is being driven, then that input will present a 100 differential load. For example, if a 50 single-ended source is driving the ADC, then a 1:2 balun will transform the impedance to 100 differential. However, if the ADC is being driven in DESIQ Mode, then the 100 differential impedance from the I-input will appear in parallel with the Q-input for a composite load of 50 differential and a 1:1 balun would be appropriate. See Figure 15 for an example circuit driving the ADC in DESIQ Mode. A recommended part selection is using the Mini-Circuits TC1-1-13MA+ balun with Ccouple = 0.22F. 17.0 Applications Information 17.1 THE ANALOG INPUTS The ADC10D1000/1500 will continuously convert any signal which is present at the analog inputs, as long as a CLK signal is also provided to the device. This section covers important aspects related to the analog inputs including: acquiring the input, the reference voltage and FSR, out-of-range indication, AC/DC-coupled signals, and single-ended input signals. 17.1.1 Acquiring the Input Data is acquired at the rising edge of CLK+ in Non-DES Mode and both the falling and rising edges of CLK+ in DES Mode. The digital equivalent of that data is available at the digital outputs a constant number of sampling clock cycles later for the DI, DQ, DId and DQd output buses, a.k.a. Latency, depending on the demultiplex mode which is selected. See tLAT in Table 13. In addition to the Latency, there is a constant output delay, t OD, before the data is available at the outputs. See tOD in Table 13 and the Timing Diagrams. The output latency versus Demux/Non-Demux Mode is shown in Table 23 and Table 24, respectively. For DES Mode, note that the I- and Q-channel inputs are available in ECM, but only the I-channel input is available in Non-ECM. TABLE 23. Output Latency in Demux Mode Data Non-DES Mode DES Mode Q-input* I-input I-input sampled Q-input sampled I-input sampled with rise of CLK, with rise of CLK, with rise of CLK, 34 cycles earlier 34 cycles earlier 34 cycles earlier DI Q-input sampled I-input sampled Q-input sampled with fall of CLK, with fall of CLK, DQ with rise of CLK, 34.5 cycles 34.5 cycles 34 cycles earlier earlier earlier I-input sampled Q-input sampled I-input sampled DId with rise of CLK, with rise of CLK, with rise of CLK, 35 cycles earlier 35 cycles earlier 35 cycles earlier Q-input sampled I-input sampled Q-input sampled with fall of CLK, with fall of CLK, DQd with rise of CLK, 35.5 cycles 35.5 cycles 35 cycles earlier earlier earlier 30066313 FIGURE 15. Driving DESIQ Mode 17.1.3 Terminating Unused Analog Inputs In the case that only one channel is used in Non-DES Mode or that the ADC is driven in DESI or DESQ Mode, the unused analog input should be terminated to reduce any noise coupling into the ADC. See Table 25 for details. TABLE 24. Output Latency in Non-Demux Mode Data Non-DES Mode DI DES Mode Q-input* I-input I-input sampled Q-input sampled I-input sampled with rise of CLK, with rise of CLK, with rise of CLK, 34 cycles earlier 34 cycles earlier 34 cycles earlier TABLE 25. Unused Analog Input Recommended Termination Q-input sampled I-input sampled Q-input sampled with rise of CLK, with rise of CLK, DQ with rise of CLK, 34.5 cycles 34.5 cycles 34 cycles earlier earlier earlier DId No output; high impedance. DQd No output; high impedance. *Available in ECM only. www.national.com 52 Mode Power Down Coupling Recommended Termination Non-DES Yes AC/DC Tie Unused+ and Unused- to Vbg DES/ Non- No DES DC Tie Unused+ and Unused- to Vbg DES/ Non- No DES AC Tie Unused+ to Unused- nected to AC ground, e.g. through capacitors to ground . Do not connect an unused analog input directly to ground. 17.1.5 Out-Of-Range Indication Differential input signals are digitized to 10 bits, based on the full-scale range. Signal excursions beyond the full-scale range, i.e. greater than +VIN_FSR/2 or less than -VIN_FSR/2, will be clipped at the output. An input signal which is above the FSR will result in all 1's at the output and an input signal which is below the FSR will result in all 0's at the output. When the conversion result is clipped for the I-channel input, the Outof-Range I-channel (ORI) output is activated such that ORI+ goes high and ORI- goes low while the signal is out of range. This output is active as long as accurate data on either or both of the buses would be outside the range of 000h to 3FFh. The Q-channel has a separate ORQ which functions similarly. 17.1.8 DC-coupled Input Signals In DC-coupled Mode, the ADC10D1000/1500 differential inputs must have the correct common-mode voltage. This voltage is provided by the device itself at the VCMO output pin. It is recommended to use this voltage because the VCMO output potential will change with temperature and the common-mode voltage of the driving device should track this change. Fullscale distortion performance falls off as the input common mode voltage deviates from VCMO. Therefore, it is recommended to keep the input common-mode voltage within 100 mV of VCMO (typical), although this range may be extended to 150 mV (maximum). See VCMI in Table 8 and ENOB vs. VCMI in Section 15.0 Typical Performance Plots . Performance in AC- and DC-coupled Mode are similar, provided that the input common mode voltage at both analog inputs remains within 100 mV of VCMO. 30066344 FIGURE 16. AC-coupled Differential Input The analog inputs for the ADC10D1000/1500 are internally buffered, which simplifies the task of driving these inputs and the RC pole which is generally used at sampling ADC inputs is not required. If the user desires to place an amplifier circuit before the ADC, care should be taken to choose an amplifier with adequate noise and distortion performance, and adequate gain at the frequencies used for the application. 17.1.6 Maximum Input Range The recommended operating and absolute maximum input range may be found in Section 10.0 Operating Ratings and Section 9.0 Absolute Maximum Ratings, respectively. Under the stated allowed operating conditions, each Vin+ and Vininput pin may be operated in the range from 0V to 2.15V if the input is a continuous 100% duty cycle signal and from 0V to 2.5V if the input is a 10% duty cycle signal. The absolute maximum input range for Vin+ and Vin- is from -0.15V to 2.5V. These limits apply only for AC input signals for which the input common mode voltage is properly maintained. 17.1.9 Single-Ended Input Signals The analog inputs of the ADC10D1000/1500 are not designed to accept single-ended signals. The best way to handle single-ended signals is to first convert them to differential signals before presenting them to the ADC. The easiest way to accomplish single-ended to differential signal conversion is with an appropriate balun-transformer, as shown in Figure 17. 17.1.7 AC-coupled Input Signals The ADC10D1000/1500 analog inputs require a precise common-mode voltage. This voltage is generated on-chip when AC-coupling Mode is selected. See Section 16.2.1.10 AC/ DC-Coupled Mode Pin (VCMO) for more information about how to select AC-coupled Mode. In AC-coupled Mode, the analog inputs must of course be ACcoupled. For an ADC10D1000/1500 used in a typical application, this may be accomplished by on-board capacitors, as shown in Figure 16. For the ADC10D1000/1500RB, the SMA inputs on the Reference Board are directly connected to the analog inputs on the ADC10D1000/1500, so this may be accomplished by DC blocks (included with the hardware kit). When the AC-coupled Mode is selected, an analog input channel that is not used (e.g. in DES Mode) should be con- 30066343 FIGURE 17. Single-Ended to Differential Conversion Using a Balun When selecting a balun, it is important to understand the input architecture of the ADC. The impedance of the analog source should be matched to the ADC10D1000/1500's on-chip 53 www.national.com ADC10D1000/1500 17.1.4 FSR and the Reference Voltage The full-scale analog differential input range (VIN_FSR) of the ADC10D1000/1500 is derived from an internal 1.254V bandgap reference. In Non-ECM, this full-scale range has two settings controlled by the FSR Pin; see Section 16.2.1.9 FullScale Input Range Pin (FSR). The FSR Pin operates on both I- and Q-channels. In ECM, the full-scale range may be independently set for each channel via Addr:3h and Bh with 15 bits of precision; see Section 18.0 Register Definitions. The best SNR is obtained with a higher full-scale input range, but better distortion and SFDR are obtained with a lower full-scale input range. It is not possible to use an external analog reference voltage to modify the full-scale range, and this adjustment should only be done digitally, as described. A buffered version of the internal 1.254V bandgap reference voltage is made available at the VBG Pin for the user. The VBG pin can drive a load of up to 80 pF and source or sink up to 100 A. It should be buffered if more current than this is required. This pin remains as a constant reference voltage regardless of what full-scale range is selected and may be used for a system reference. VBG is a dual-purpose pin and it may also be used to select a higher LVDS output commonmode voltage; see Section 16.2.1.11 LVDS Output Commonmode Pin (VBG). ADC10D1000/1500 100 differential input termination resistor. The range of this termination resistor is specified as RIN in Table 8. proved ADC clocking, especially in the Dual-Edge Sampling (DES) Mode. 17.2 THE CLOCK INPUTS The ADC10D1000/1500 has a differential clock input, CLK+ and CLK-, which must be driven with an AC-coupled, differential clock signal. This provides the level shifting to the clock to be driven with LVDS, PECL, LVPECL, or CML levels. The clock inputs are internally terminated to 100 differential and self-biased. This section covers coupling, frequency range, level, duty-cycle, jitter, and layout considerations. 17.2.5 CLK Jitter High speed, high performance ADCs such as the ADC10D1000/1500 require a very stable input clock signal with minimum phase noise or jitter. ADC jitter requirements are defined by the ADC resolution (number of bits), maximum ADC input frequency and the input signal amplitude relative to the ADC input full scale range. The maximum jitter (the sum of the jitter from all sources) allowed to prevent a jitter-induced reduction in SNR is found to be 17.2.1 CLK Coupling The clock inputs of the ADC10D1000/1500 must be capacitively coupled to the clock pins as indicated in Figure 18. tJ(MAX) = ( VIN(P-P)/ VFSR) x (1/(2(N+1) x x fIN)) where tJ(MAX) is the rms total of all jitter sources in seconds, VIN(P-P) is the peak-to-peak analog input signal, VFSR is the full-scale range of the ADC, "N" is the ADC resolution in bits and fIN is the maximum input frequency, in Hertz, at the ADC analog input. tJ(MAX) is the square root of the sum of the squares (RSS) sum of the jitter from all sources, including: the ADC input clock, system, input signals and the ADC itself. Since the effective jitter added by the ADC is beyond user control, it is recommended to keep the sum of all other externally added jitter to a minimum. 17.2.6 CLK Layout The ADC10D1000/1500 clock input is internally terminated with a trimmed 100 resistor. The differential input clock line pair should have a characteristic impedance of 100 and (when using a balun), be terminated at the clock source in that (100) characteristic impedance. It is good practice to keep the ADC input clock line as short as possible, to keep it well away from any other signals and to treat it as a transmission line. Otherwise, other signals can introduce jitter into the input clock signal. Also, the clock signal can introduce noise into the analog path if it is not properly isolated. 30066347 FIGURE 18. Differential Input Clock Connection The choice of capacitor value will depend on the clock frequency, capacitor component characteristics and other system economic factors. For example, on the ADC10D1000/1500RB, the capacitors have the value Ccouple = 4.7 nF which yields a highpass cutoff frequency, fc = 677.2 kHz. 17.2.2 CLK Frequency Although the ADC10D1000/1500 is tested and its performance is guaranteed with a differential 1.0/1.5 GHz sampling clock, it will typically function well over the input clock frequency range; see fCLK(min) and fCLK(max) in Table 13. Operation up to fCLK(max) is possible if the maximum ambient temperatures indicated are not exceeded. Operating at sample rates above fCLK(max) for the maximum ambient temperature may result in reduced device reliability and product lifetime. This is due to the fact that higher sample rates results in higher power consumption and die temperatures. If fCLK < 300 MHz, enable LFS in the Control Register (Addr: 0h, Bit 8). 17.3 THE LVDS OUTPUTS The Data, ORI, ORQ, DCLKI and DCLKQ outputs are LVDS. The electrical specifications of the LVDS outputs are compatible with typical LVDS receivers available on ASIC and FPGA chips; but they are not IEEE or ANSI communications standards compliant due to the low +1.9V supply used on this chip. These outputs should be terminated with a 100 differential resistor placed as closely to the receiver as possible. This section covers common-mode and differential voltage, and data rate. 17.3.1 Common-mode and Differential Voltage The LVDS outputs have selectable common-mode and differential voltage, VOS and VOD; see Table 11. See Section 16.3.2 Output Control and Adjust for more information. Selecting the higher VOS will also increase VOD slightly. The differential voltage, VOD, may be selected for the higher or lower value. For short LVDS lines and low noise systems, satisfactory performance may be realized with the lower VOD. This will also result in lower power consumption. If the LVDS lines are long and/or the system in which the ADC10D1000/1500 is used is noisy, it may be necessary to select the higher VOD. 17.2.3 CLK Level The input clock amplitude is specified as VIN_CLK in Table 10. Input clock amplitudes above the max VIN_CLK may result in increased input offset voltage. This would cause the converter to produce an output code other than the expected 511/512 when both input pins are at the same potential. Insufficient input clock levels will result in poor dynamic performance. Both of these results may be avoided by keeping the clock input amplitude within the specified limits of VIN_CLK. 17.2.4 CLK Duty Cycle The duty cycle of the input clock signal can affect the performance of any A/D converter. The ADC10D1000/1500 features a duty cycle clock correction circuit which can maintain performance over the 20%-to-80% specified clock duty-cycle range. This feature is enabled by default and provides im- www.national.com 17.3.2 Output Data Rate The data is produced at the output at the same rate as it is sampled at the input. The minimum recommended input clock rate for this device is fCLK(MIN); see Table 13. However, it is 54 17.3.3 Terminating RSV Pins The RSV pins are used for internal purposes. They may be left unconnected and floating or connected as shown in Figure 19. TABLE 26. Unused AutoSync and DCLK Reset Pin Recommendation 30066336 Pin(s) Unused termination RCLK+/- Do not connect. RCOUT1+/- Do not connect. RCOUT2+/- Do not connect. DCLK_RST+ Connect to GND via 1k resistor. DCLK_RST- Connect to VA via 1k resistor. 17.4.1 AutoSync Feature AutoSync is a new feature which continuously synchronizes the outputs of multiple ADC10D1000/1500s in a system. It may be used to synchronize the DCLK and data outputs of one or more Slave ADC10D1000/1500s to one Master ADC10D1000/1500. Several advantages of this feature include: no special synchronization pulse required, any upset in synchronization is recovered upon the next DCLK cycle, and the Master/Slave ADC10D1000/1500s may be arranged as a binary tree so that any upset will quickly propagate out of the system. An example system is shown below in Figure 20 which consists of one Master ADC and two Slave ADCs. For simplicity, only one DCLK is shown; in reality, there is DCLKI and DCLKQ, but they are always in phase with one another. FIGURE 19. RSV Pin Connection This board configuration is recommended if the RSV pins are connected to FPGA input pins and must be forced to a known voltage. The value of the 100 resistor should not be changed, but the 1k resistors may be changed based upon the requirements of the specific FPGA. 17.3.4 Terminating Unused LVDS Output Pins If the ADC is used in Non-Demux Mode, then only the DI and DQ data outputs will have valid data present on them. The DId and DQd data outputs may be left not connected; if unused, they are internally tri-stated. Similarly, if the Q-channel is powered-down (i.e. PDQ is logichigh), the DQ data output pins, DCLKQ and ORQ should be left not connected. 17.4 SYNCHRONIZING MULTIPLE ADC10D1000/1500S IN A SYSTEM The ADC10D1000/1500 has two features to assist the user with synchronizing multiple ADCs in a system; AutoSync and 30066303 FIGURE 20. AutoSync Example 55 www.national.com ADC10D1000/1500 DCLK Reset. The AutoSync feature is new and designates one ADC10D1000/1500 as the Master ADC and other ADC10D1000/1500s in the system as Slave ADCs. The DCLK Reset feature performs the same function as the AutoSync feature, but is the first generation solution to synchronizing multiple ADCs in a system; it is disabled by default. For the application in which there are multiple Master and Slave ADC10D1000/1500s in a system, AutoSync may be used to synchronize the Slave ADC10D1000/1500(s) to each respective Master ADC10D1000/1500 and the DCLK Reset may be used to synchronize the Master ADC10D1000/1500s to each other. If the AutoSync or DCLK Reset feature is not used, see Table 26 for recommendations about terminating unused pins. possible to operate the device in 1:2 Demux Mode and capture data from just one 10-bit bus, e.g. just DI (or DId) although both DI and DId are fully operational. This will decimate the data by two and effectively halve the data rate. ADC10D1000/1500 In order to synchronize the DCLK (and Data) outputs of multiple ADCs, the DCLKs must transition at the same time, as well as be in phase with one another. The DCLK at each ADC is generated from the CLK after some latency, plus tOD minus tAD. Therefore, in order for the DCLKs to transition at the same time, the CLK signal must reach each ADC at the same time. To tune out any differences in the CLK path to each ADC, the tAD adjust feature may be used. However, using the tAD adjust feature will also affect when the DCLK is produced at the output. If the device is in Demux Mode, then there are four possible phases which each DCLK may be generated on because the typical CLK = 1GHz and DCLK = 250 MHz for this case. The RCLK signal controls the phase of the DCLK, so that each Slave DCLK is on the same phase as the Master DCLK. The AutoSync feature may only be used via the Control Registers. 17.5 SUPPLY/GROUNDING, LAYOUT AND THERMAL RECOMMENDATIONS 17.5.1 Power Planes All supply buses for the ADC should be sourced from a common linear voltage regulator. This ensures that all power buses to the ADC are turned on and off simultaneously. This single source will be split into individual sections of the power plane, with individual decoupling and connection to the different power supply buses of the ADC. Due to the low voltage but relatively high supply current requirement, the optimal solution may be to use a switching regulator to provide an intermediate low voltage, which is then regulated down to the final ADC supply voltage by a linear regulator. Please refer to the documentation provided for the ADC10D1000/1500RB for additional details on specific regulators that are recommended for this configuration. Power for the ADC should be provided through a broad plane which is located on one layer adjacent to the ground plane(s). Placing the power and ground planes on adjacent layers will provide low impedance decoupling of the ADC supplies, especially at higher frequencies. The output of a linear regulator should feed into the power plane through a low impedance multi-via connection. The power plane should be split into individual power peninsulas near the ADC. Each peninsula should feed a particular power bus on the ADC, with decoupling for that power bus connecting the peninsula to the ground plane near each power/ground pin pair. Using this technique can be difficult on many printed circuit CAD tools. To work around this, zero ohm resistors can be used to connect the power source net to the individual nets for the different ADC power buses. As a final step, the zero ohm resistors can be removed and the plane and peninsulas can be connected manually after all other error checking is completed. 17.4.2 DCLK Reset Feature The DCLK reset feature is available via ECM, but it is disabled by default. DCLKI and DCLKQ are always synchronized, by design, and do not require a pulse from DCLK_RST to become synchronized. The DCLK_RST signal must observe certain timing requirements, which are shown in Figure 9 of the Timing Diagrams. The DCLK_RST pulse must be of a minimum width and its deassertion edge must observe setup and hold times with respect to the CLK input rising edge. These timing specifications are listed as tPWR, tSR and tHR and may be found in Table 13. The DCLK_RST signal can be asserted asynchronously to the input clock. If DCLK_RST is asserted, the DCLK output is held in a designated state (logic-high) in Demux Mode; in Non-Demux Mode, the DCLK continues to function normally. Depending upon when the DCLK_RST signal is asserted, there may be a narrow pulse on the DCLK line during this reset event. When the DCLK_RST signal is de-asserted, there are tSYNC_DLY CLK cycles of systematic delay and the next CLK rising edge synchronizes the DCLK output with those of other ADC10D1000/1500s in the system. For 90 Mode (DDRPh = logic-high), the synchronizing edge occurs on the rising edge of CLK, 4 cycles after the first rising edge of CLK after DCLK_RST is released. For 0 Mode (DDRPh = logic-low), this is 5 cycles instead. The DCLK output is enabled again after a constant delay of tOD. For both Demux and Non-Demux Modes, there is some uncertainty about how DCLK comes out of the reset state for the first DCLK_RST pulse. For the second (and subsequent) DCLK_RST pulses, the DCLK will come out of the reset state in a known way. Therefore, if using the DCLK Reset feature, it is recommended to apply one "dummy" DCLK_RST pulse before using the second DCLK_RST pulse to synchronize the outputs. This recommendation applies each time the device or channel is powered-on. When using DCLK_RST to synchronize multiple ADC10D1000/1500s, it is required that the Select Phase bits in the Control Register (Addr: Eh, Bits 3,4) be the same for each Master ADC10D1000/1500. www.national.com 17.5.2 Bypass Capacitors The general recommendation is to have one 100nF capacitor for each power/ground pin pair. The capacitors should be surface mount multi-layer ceramic chip capacitors similar to Panasonic part number ECJ-0EB1A104K. 17.5.3 Ground Planes Grounding should be done using continuous full ground planes to minimize the impedance for all ground return paths, and provide the shortest possible image/return path for all signal traces. 17.5.4 Power System Example The ADC10D1000/1500RB uses continuous ground planes (except where clear areas are needed to provide appropriate impedance management for specific signals), see Figure 21. Power is provided on one plane, with the 1.9V ADC supply being split into multiple zones or peninsulas for the specific power buses of the ADC. Decoupling capacitors are connected between these power bus peninsulas and the adjacent power planes using vias. The capacitors are located as close to the individual power/ground pin pairs of the ADC as possible. In most cases, this means the capacitors are located on the opposite side of the PCB to the ADC. 56 ADC10D1000/1500 30066302 FIGURE 21. Power and Grounding Example 57 www.national.com ADC10D1000/1500 attached to the substrate top with exposed metal in the center top area of the package. This results in a 20% improvement (typical) in thermal performance over the standard plastic BGA package. 17.5.5 Thermal Management The Heat Slug Ball Grid Array (HSBGA) package is a modified version of the industry standard plastic BGA (Ball Grid Array) package. Inside the package, a copper heat spreader cap is 30066309 FIGURE 22. HSBGA Conceptual Drawing The center balls are connected to the bottom of the die by vias in the package substrate, Figure 22. This gives a low thermal resistance between the die and these balls. Connecting these balls to the PCB ground planes with a low thermal resistance path is the best way dissipate the heat from the ADC. These pins should also be connected to the ground plane via a low impedance path for electrical purposes. The direct connection to the ground planes is an easy method to spread heat away from the ADC. Along with the ground plane, the parallel power planes will provide additional thermal dissipation. The center ground balls should be soldered down to the recommended ball pads (See AN-1126). These balls will have wide traces which in turn have vias which connect to the internal ground planes, and a bottom ground pad/pour if possible. This ensures a good ground is provided for these balls, and that the optimal heat transfer will occur between these balls and the PCB ground planes. In spite of these package enhancements, analysis using the standard JEDEC JESD51-7 four-layer PCB thermal model shows that ambient temperatures must be limited to a max of 70C to ensure a safe operating junction temperature for the ADC10D1500. However, most applications using the ADC10D1500 will have a printed circuit board which is more complex than that used in JESD51-7. Typical circuit boards will have more layers than the JESD51-7 (eight or more), several of which will be used for ground and power planes. In those applications, the thermal resistance parameters of the ADC10D1500 and the circuit board can be used to determine the actual safe ambient operating temperature up to a maximum of 85C. Three key parameters are provided to allow for modeling and calculations. Because there are two main thermal paths between the ADC die and external environment, the thermal resistance for each of these paths is provided. JC1 represents the thermal resistance between the die and the exposed metal area on the top of the HSBGA package. JC2 represents the thermal resistance between the die and the center group of balls on the bottom of the HSBGA package. The final parameter is the allowed maximum junction temperature, which is 138C. In other applications, a heat sink or other thermally conductive path can be added to the top of the HSBGA package to remove heat. In those cases, JC1 can be used along with the thermal parameters for the heat sink or other thermal coupling www.national.com added. Representative heat sinks which might be used with the ADC10D1000/1500 include the Cool Innovations p/n 3-1212XXG and similar products from other vendors. In many applications, the printed circuit board will provide the primary thermal path conducting heat away from the ADC package. In those cases, JC2 can be used in conjunction with printed circuit board thermal modeling software to determine the allowed operating conditions that will maintain the die temperature below the maximum allowable limit. Additional dissipation can be achieved by coupling a heat sink to the copper pour area on the bottom side of the printed circuit board. Typically, dissipation will occur through one predominant thermal path. In these cases, the following calculations can be used to determine the maximum safe ambient operating temperature: TJ = TA + PD x (JC+CA) 138C = TA + 3.98W x (JC+CA) For JC, the value for the primary thermal path in the given application environment should be used (JC1 or JC2). CA is the thermal resistance from the case to ambient, which would typically be that of the heat sink used. Using this relationship and the desired ambient temperature, the required heat sink thermal resistance can be found. Alternately, the heat sink thermal resistance can be used to find the maximum ambient temperature. For more complex systems, thermal modeling software can be used to evaluate the printed circuit board system and determine the expected junction temperature given the total system dissipation and ambient temperature. 17.6 SYSTEM POWER-ON CONSIDERATIONS There are a couple important topics to consider associated with the system power-on event including configuration and calibration, and the Data Clock. 17.6.1 Power-on, Configuration, and Calibration Following the application of power to the ADC10D1000/1500, several events must take place before the output from the ADC10D1000/1500 is valid and at full performance; at least one full calibration must be executed with the device configured in the desired mode. Following the application of power to the ADC10D1000/1500, there is a delay of tCalDly and then the Power-on Calibration is executed. This is why it is recommended to set the CalDly Pin via an external pull-up or pull-down resistor. Then, the state 58 Another case is when the FPGA writes to the Control Pins (Non-ECM) or to the SPI (ECM), see Figure 24. It is always necessary to comply with the Operating Ratings and Absolute Maximum ratings, i.e. the Control Pins may not be driven below the ground or above the supply, regardless of what the voltage currently applied to the supply is. Therefore, it is not recommended to write to the Control Pins or SPI before power is applied to the ADC10D1000/1500. As long as the FPGA has completed writing to the Control Pins or SPI, the Poweron Calibration will result in a valid output at full performance. Once again, if it takes longer than tCalDly for the system to stabilize at its operating temperature, it is recommended to execute an on-command calibration at that time. Due to system requirements, it may not be possible for the FPGA to write to the Control Pins or SPI before the Power-on Calibration takes place, see Figure 25. It is not critical to configure the device before the Power-on Calibration, but it is critical to realize that the output for such a case is not at its full performance. Following an On-command Calibration, the device will be at its full performance. 30066364 FIGURE 23. Power-on with Control Pins set by Pull-up/down Resistors 30066365 FIGURE 24. Power-on with Control Pins set by FPGA pre Power-on Cal 59 www.national.com ADC10D1000/1500 of that input will be determined at the same time that power is applied to the ADC and tCalDly will be a known quantity. For the purpose of this section, it is assumed that CalDly is set as recommended. The Control Bits or Pins must be set or written to configure the ADC10D1000/1500 in the desired mode. This must take place via either Extended Control Mode or Non-ECM (Pin Control Mode) before subsequent calibrations will yield an output at full performance in that mode. Some examples of modes include DES/Non-DES Mode, Demux/Non-demux Mode, and Full-Scale Range. The simplest case is when device is in Non-ECM and the Control Pins are set by pull-up/down resistors, see Figure 23. For this case, the settings to the Control Pins ramp concurrently to the ADC voltage. Following the delay of tCalDly and the calibration execution time, tCAL, the output of the ADC10D1000/1500 is valid and at full performance. If it takes longer than tCalDly for the system to stabilize at its operating temperature, it is recommended to execute an on-command calibration at that time. ADC10D1000/1500 30066366 FIGURE 25. Power-on with Control Pins set by FPGA post Power-on Cal 17.6.2 Power-on and Data Clock (DCLK) Many applications use the DCLK output for a system clock. For the ADC10D1000/1500, each I- and Q-channel has its own DCLKI and DCLKQ, respectively. The DCLK output is always active, unless that channel is powered-down or the DCLK Reset feature is used while the device is in Demux Mode. As the supply to the ADC10D1000/1500 ramps, the DCLK also comes up, see this example from the ADC10D1000/1500RB: Figure 26. While the supply is too low, there is no output at DCLK. As the supply continues to ramp, DCLK functions intermittently with irregular frequency, but the amplitude continues to track with the supply. Much below the low end of operating supply range of the ADC10D1000/1500, the DCLK is already fully operational. 17.7.1 Temperature Sensor The ADC10D1000/1500 has an on-die temperature diode connected to pins Tdiode+/- which may be used to monitor the die temperature. National also provides a family of temperature sensors for this application which monitor different numbers of external devices, see Table 27. TABLE 27. Temperature Sensor Recommendation Recommended Temperature Sensor 1 LM95235 2 LM95213 4 LM95214 The temperature sensor (LM95235/13/14) is an 11-bit digital temperature sensor with a 2-wire System Management Bus (SMBus) interface that can monitor the temperature of one, two, or four remote diodes as well as its own temperature. It can be used to accurately monitor the temperature of up to one, two, or four external devices such as the ADC10D1000/1500, a FPGA, other system components, and the ambient temperature. The temperature sensor reports temperature in two different formats for +127.875C/-128C range and 0/255C range. It has a Sigma-Delta ADC core which provides the first level of noise immunity. For improved performance in a noise environment, the temperature sensor includes programmable digital filters for Remote Diode temperature readings. When the digital filters are invoked, the resolution for the Remote Diode readings increases to 0.03125C. For maximum flexibility and best accuracy, the temperature sensor includes offset registers that allow calibration of other diode types. Diode fault detection circuitry in the temperature sensor can detect the absence or fault state of a remote diode: whether D+ is shorted to the power supply, D- or ground, or floating. In the following of a typical application, the LM95213 is used to monitor the temperature of an ADC10D1000/1500 as well as a FPGA, see Figure 27. 30066390 FIGURE 26. Supply and DCLK Ramping 17.7 RECOMMENDED SYSTEM CHIPS National recommends these other chips including temperature sensors, clocking devices, and amplifiers in order to support the ADC10D1000/1500 in a system design. www.national.com Number of External Devices Monitored 60 ADC10D1000/1500 30066397 FIGURE 27. Typical Temperature Sensor Application neither of which can be provided with a transformer coupled input circuit: 17.7.2 Clocking Device The clock source can be a PLL/VCO device such as the LMX2531LQxxxx family of products. The specific device should be selected according to the desired ADC sampling clock frequency. The ADC10D1000/1500RB uses the LMX2531LQ1510E, with the ADC clock source provided by the Aux PLL output. Other devices which may be considered based on clock source, jitter cleaning, and distribution purposes are the LMK01XXX, LMK02XXX, LMK03XXX and LMK04XXX product families. TABLE 28. Amplifier Recommendation 17.7.3 Amplifier The following amplifiers can be used for ADC10D1000/1500 applications which require DC coupled input or signal gain, 61 Amplifier Bandwidth Brief features LMH6552 1.5 GHz Configurable gain LMH6553 900 MHz Output clamp and configurable gain LMH6554 2.5 GHz Configurable gain LMH6555 1.2 GHz Fixed gain www.national.com ADC10D1000/1500 18.0 Register Definitions Ten read/write registers provide several control and configuration options in the Extended Control Mode. These registers have no effect when the device is in the Non-extended Control Mode. Each register description below also shows the Power-On Reset (POR) state of each control bit. See Table 29 for a summary. For a description of the functionality and timing to read/write the control registers, see Section 16.2.2.1 The Serial Interface. TABLE 29. Register Addresses www.national.com A3 A2 A1 A0 Hex Register Addressed 0 0 0 0 0h Configuration Register 1 0 0 0 1 1h VCMO Adjust 0 0 1 0 2h I-channel Offset 0 0 1 1 3h I-channel FSR 0 1 0 0 4h Calibration Adjust 0 1 0 1 5h Reserved 0 1 1 0 6h Reserved 0 1 1 1 7h Reserved 1 0 0 0 8h Reserved 1 0 0 1 9h Reserved 1 0 1 0 Ah Q-channel Offset 1 0 1 1 Bh Q-channel FSR 1 1 0 0 Ch Aperture Delay Coarse Adjust 1 1 0 1 Dh Aperture Delay Fine Adjust and LC Filter Adjust 1 1 1 0 Eh AutoSync 1 1 1 1 Fh Reserved 62 Addr: 0h (0000b) Bit 15 Name CAL POR Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bits 3:0 POR state: 2000h 14 13 12 11 10 9 8 7 6 5 4 DPS OVS TPM PDI PDQ Res LFS DES DEQ DIQ 2SC 0 1 0 0 0 0 0 0 0 0 0 0 3 2 0 0 1 0 0 0 Res CAL: Calibration Enable. When this bit is set to 1b, an on-command calibration is initiated. This bit is not reset automatically upon completion of the calibration. Therefore, the user must reset this bit to 0b and then set it to 1b again to execute another calibration. This bit is logically OR'd with the CAL Pin; both bit and pin must be set to 0b before either is used to execute a calibration. DPS: DDR Phase Select. Set this bit to 0b to select the 0 Mode DDR Data-to-DCLK phase relationship and to 1b to select the 90 Mode. This bit has no effect when the device is in Non-Demux Mode. OVS: Output Voltage Select. This bit sets the differential voltage level for the LVDS outputs including Data, OR, and DCLK. 0b selects the lower level and 1b selects the higher level. See VOD in Table 11for details. TPM: Test Pattern Mode. When this bit is set to 1b, the device will continually output a fixed digital pattern at the digital Data and OR outputs. When set to 0b, the device will continually output the converted signal, which was present at the analog inputs. See Section 16.3.2.6 Test Pattern Mode for details about the TPM pattern. PDI: Power-down I-channel. When this bit is set to 0b, the I-channel is fully operational, but when it is set to 1b, the I-channel is powered-down. The I-channel may be powered-down via this bit or the PDI Pin, which is active, even in ECM. PDQ: Power-down Q-channel. When this bit is set to 0b, the Q-channel is fully operational, but when it is set to 1b, the Q-channel is powered-down. The Q-channel may be powered-down via this bit or the PDQ Pin, which is active, even in ECM. Reserved. Must be set to 0b. LFS: Low-Frequency Select. If the sampling clock (CLK) is at or below 300 MHz, set this bit to 1b. DES: Dual-Edge Sampling Mode select. When this bit is set to 0b, the device will operate in the Non-DES Mode; when it is set to 1b, the device will operate in the DES Mode. See Section 16.3.1.4 DES/Non-DES Mode for more information. DEQ: DES Q-input select, a.k.a. DESQ Mode. When the device is in DES Mode, this bit can select the input that the device will operate on. The default setting of 0b selects the I-input and 1b selects the Q-input. DIQ: DES I- and Q-input, a.k.a. DESIQ Mode. When in DES Mode, setting this bit to 1b shorts the I- and Qinputs. If the bit is left at its default 0b, the I- and Q-inputs remain electrically separate. To operate the device in DESIQ Mode, Bits<7:5> must be set to 101b. In this mode, both the I- and Q-inputs must be externally driven. 2SC: Two's Complement output. For the default setting of 0b, the data is output in Offset Binary format; when set to 1b, the data is output in Two's Complement format. Reserved. Must be set to 0b. VCMO Adjust Addr: 1h (0001b) Bit POR state: 2A00h 15 14 13 12 0 0 1 0 10 9 8 7 1 0 1 0 0 Res Name POR 11 6 5 4 3 0 0 0 VCA(2:0) 0 2 1 0 0 0 Res 0 Bits 15:8 Reserved. Must be set as shown. Bits 7:5 VCA(2:0): VCMO Adjust. Adjusting from the default VCA(2:0) = 0d to VCA(2:0) = 7d decreases VCMO from it's typical value (see VCMO in Table 8) to 1.05V by increments of ~28.6 mV. Bits 4:0 Code VCMO 000 (default) VCMO 100 VCMO- 114 mV 111 VCMO- 200 mV Reserved. Must be set as shown. 63 www.national.com ADC10D1000/1500 Configuration Register 1 ADC10D1000/1500 I-channel Offset Adjust Addr: 2h (0010b) Bit 15 14 13 Res Name POR POR state: 0000h 0 0 12 11 10 9 8 7 OS 0 0 6 5 4 3 2 1 0 0 0 0 0 0 OM(11:0) 0 0 0 0 0 0 0 Bits 15:13 Reserved. Must be set to 0b. Bit 12 OS: Offset Sign. The default setting of 0b incurs a positive offset of a magnitude set by Bits 11:0 to the ADC output. Setting this bet to 1b incurs a negative offset of the set magnitude. Bits 11:0 OM(11:0): Offset Magnitude. These bits determine the magnitude of the offset set at the ADC output (straight binary coding). The range is from 0 mV for OM(11:0) = 0d to 45 mV for OM(11:0) = 4095d in steps of ~11 V. Monotonicity is guaranteed by design only for the 9 MSBs. Code Offset [mV] 0000 0000 0000 (default) 0 1000 0000 0000 22.5 1111 1111 1111 45 I-channel Full Scale Range Adjust Addr: 3h (0011b) Bit 15 Name Res POR 0 POR state: 4000h 14 13 12 11 10 9 8 1 0 0 0 0 0 0 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 FM(14:0) 0 Bit 15 Reserved. Must be set to 0b. Bits 14:0 FM(14:0): FSR Magnitude. These bits increase the ADC full-scale range magnitude (straight binary coding.) The range is from 600 mV (0d) to 980 mV (32767d) with the default setting at 790 mV (16384d). Monotonicity is guaranteed by design only for the 9 MSBs. The mid-range (low) setting in ECM corresponds to the nominal (low) setting in Non-ECM. A greater range of FSR values is available in ECM, i.e. FSR values above 790 mV. See VIN_FSR in Table 8 for characterization details. Code 000 0000 0000 0000 100 0000 0000 0000 (default) 111 1111 1111 1111 FSR [mV] 600 790 980 Calibration Adjust Addr: 4h (0100b) POR state: DA7Fh Bit 15 14 Name Res CSS POR 1 1 www.national.com 13 12 0 1 11 10 1 0 Res 9 8 CMS(1:0) 1 0 64 7 6 5 4 1 1 1 SSC 0 3 2 1 0 1 1 1 Res 1 Reserved. Must be set as shown. CSS: Calibration Sequence Select. The default 1b selects the following calibration sequence: reset all previously calibrated elements to nominal values, do RIN Calibration, do internal linearity Calibration. Setting CSS = 0b selects the following calibration sequence: do not reset RIN to its nominal value, skip RIN calibration, do internal linearity Calibration. The calibration must be completed at least one time with CSS = 1b to calibrate RIN. Subsequent calibrations may be run with CSS = 0b (skip RIN calibration) or 1b (full RIN and internal linearity Calibration). Bits 13:10 Reserved. Must be set as shown. Bits 9:8 CMS(1:0): Calibration Mode Select. These bits affect the length of time taken to calibrate the internal linearity. See tCAL in Table 13. Bit 7 Bits 6:0 SSC: SPI Scan Control. Setting this control bit to 1b allows the calibration values, stored in Addr: 5h, to be read/ written. When not reading/writing the calibration values, this control bit should left at its default 0b setting. Reserved. Must be set as shown. Calibration Values Addr: 5h (0101b) Bit 15 POR state: XXXXh 14 13 12 11 10 9 POR Bits 15:0 8 7 6 5 4 3 2 1 0 X X X X X X X SS(15:0) Name X X X X X X X X X SS(15:0): SPI Scan. When the ADC performs a self-calibration, the values for the calibration are stored in this register and may be read from/ written to it. Set SSC (Addr: 4h, Bit 7) to read/write. Reserved Addr: 6h (0110b) Bit 15 POR state: 1C70h 14 13 12 11 10 9 8 Bits 15:0 6 5 4 3 2 1 0 0 1 1 1 0 0 0 0 Res Name POR 7 0 0 0 1 1 1 0 0 Reserved. Must be set as shown. Reserved Addr: 7h (0111b) Bit 15 POR state: 0000h 14 13 12 11 10 9 8 POR Bits 15:0 7 6 5 4 3 2 1 0 0 0 0 Res Name 0 0 0 0 0 0 0 0 0 0 0 0 0 10 9 8 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 Reserved. Must be set as shown. Reserved Addr: 8h (1000b) Bit 15 POR state: 0000h 14 13 12 11 Res Name POR Bits 15:0 0 0 0 0 0 0 0 0 Reserved. Must be set as shown. 65 www.national.com ADC10D1000/1500 Bit 15 Bit 14 ADC10D1000/1500 Reserved Addr: 9h (1001b) 15 Bit POR state: 0000h 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0 0 0 Res Name 0 POR Bits 15:0 0 0 0 0 0 0 0 0 0 0 0 0 10 9 8 7 6 5 4 3 2 1 0 0 0 0 0 0 Reserved. Must be set as shown. Q-channel Offset Adjust Addr: Ah (1010b) Bit 15 POR state: 0000h 13 Res Name POR 14 0 0 12 11 OS 0 0 OM(11:0) 0 0 0 0 0 0 0 Bits 15:13 Reserved. Must be set to 0b. Bit 12 OS: Offset Sign. The default setting of 0b incurs a positive offset of a magnitude set by Bits 11:0 to the ADC output. Setting this bet to 1b incurs a negative offset of the set magnitude. Bits 11:0 OM(11:0): Offset Magnitude. These bits determine the magnitude of the offset set at the ADC output (straight binary coding). The range is from 0 mV for OM(11:0) = 0d to 45 mV for OM(11:0) = 4095d in steps of ~11 V. Monotonicity is guaranteed by design only for the 9 MSBs. Code Offset [mV] 0000 0000 0000 (default) 0 1000 0000 0000 22.5 1111 1111 1111 45 Q-channel Full-Scale Range Adjust Addr: Bh (1011b) Bit 15 Name Res POR 0 14 POR state: 4000h 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 FM(14:0) 1 0 0 0 0 0 0 0 Bit 15 Reserved. Must be set to 0b. Bits 14:0 FM(14:0): FSR Magnitude. These bits increase the ADC full-scale range magnitude (straight binary coding.) The range is from 600 mV (0d) to 980 mV (32767d) with the default setting at 790 mV (16384d). Monotonicity is guaranteed by design only for the 9 MSBs. The mid-range (low) setting in ECM corresponds to the nominal (low) setting in Non-ECM. A greater range of FSR values is available in ECM, i.e. FSR values above 790 mV. See VIN_FSR in Table 8 for characterization details. Code 000 0000 0000 0000 100 0000 0000 0000 (default) 111 1111 1111 1111 www.national.com FSR [mV] 600 790 980 66 Addr: Ch (1100b) Bit POR state: 0004h 15 14 13 12 11 0 0 0 0 0 Bits 15:4 Bit 3 Bit 2 Bits 1:0 9 8 7 6 5 4 0 0 0 0 0 CAM(11:0) Name POR 10 0 0 3 2 STA DCC 0 1 1 0 Res 0 0 CAM(11:0): Coarse Adjust Magnitude. This 12-bit value determines the amount of delay that will be applied to the input CLK signal. The range is 0 ps delay for CAM(11:0) = 0d to a maximum delay of 825 ps for CAM(11:0) = 2431d (95 ps due to PVT variation) in steps of ~340 fs. For code CAM(11:0) = 2432d and above, the delay saturates and the maximum delay applies. Additional, finer delay steps are available in register Dh. Either STA (Bit 3) or SA (Addr: Dh, Bit 8) must be selected to enable this function. STA: Select tAD Adjust. Set this bit to 1b to enable the tAD adjust feature, which will make both coarse and fine adjustment settings, i.e. CAM(11:0) and FAM(5:0), available. DCC: Duty Cycle Correct. This bit can be set to 0b to disable the automatic duty-cycle stabilizer feature of the chip. This feature is enabled by default. Reserved. Must be set to 0b. 67 www.national.com ADC10D1000/1500 Aperture Delay Coarse Adjust ADC10D1000/1500 Aperture Delay Fine Adjust and LC Filter Adjust Addr: Dh (1101b) Bit 15 14 0 0 12 11 10 0 0 FAM(5:0) Name POR POR state: 0000h 13 0 0 9 8 Res SA 0 0 7 6 5 0 0 0 4 3 2 1 0 0 0 0 LCF(7:0) 0 0 Bits 15:10 FAM(5:0): Fine Aperture Adjust Magnitude. This 6-bit value determines the amount of additional delay that will be applied to the input CLK when the Clock Phase Adjust feature is enabled via STA (Addr: Ch, Bit 3) or SA (Addr: Dh, Bit 8). The range is straight binary from 0 ps delay for FAM(5:0) = 0d to 2.3 ps delay for FAM(5:0) = 63d (300 fs due to PVT variation) in steps of ~36 fs. Bit 9 Reserved. Must be set to 0b. Bit 8 SA: Select tAD and LC filter Adjust. Set this bit to 1b to enable the tAD and LC filter adjust features. Using this bit is the same as enabling STA (Addr: Ch, Bit 3), but also enables the LC filter to clean the clock jitter. If SA is enabled, then the value of the STA bit is ignored. Bits 7:0 LCF(7:0): LC tank select Frequency. Use these bits to select the center frequency of the LC filter on the clock input. The range is from 0.8 GHz (255d) to 1.5 GHz (0d). Note that the tuning range is not binary encoded, and the eight bits are thermometer encoded, i.e. the mid value of 1.1 GHz tuning is achieved with LCF(7:0) = 0000 1111b. AutoSync Addr: Eh (1110b) Bit POR state: 0003h 15 14 13 12 0 0 0 0 Bits 15:6 Bit 5 Bits 4:3 Bit 2 Bit 1 Bit 0 10 9 8 7 6 0 0 0 0 DRC(9:0) Name POR 11 0 0 5 Res 0 4 3 SP(1:0) 0 0 2 1 0 ES DOC DR 0 1 1 DRC(9:0): Delay Reference Clock (9:0). These bits may be used to increase the delay on the input reference clock when synchronizing multiple ADCs. The minimum delay is 0s (0d) to 1000 ps (639d). The delay remains the maximum of 1000 ps for any codes above or equal to 639d. Reserved. Must be set to 0b. SP(1:0): Select Phase. These bits select the phase of the reference clock which is latched. The codes correspond to the following phase shift: 00 = 0 01 = 90 10 = 180 11 = 270 ES: Enable Slave. Set this bit to 1b to enable the Slave Mode of operation. In this mode, the internal divided clocks are synchronized with the reference clock coming from the master ADC. The master clock is applied on the input pins RCLK. If this bit is set to 0b, then the device is in Master Mode. DOC: Disable Output reference Clocks. Setting this bit to 0b sends a CLK/4 signal on RCOut1 and RCOut2. The default setting of 1b disables these output drivers. This bit functions as described, regardless of whether the device is operating in Master or Slave Mode, as determined by ES (Bit 2). DR: Disable Reset. The default setting of 1b leaves the DCLK_RST functionality disabled. Set this bit to 0b to enable DCLK_RST functionality. Reserved Addr: Fh (1111b) Bit 15 14 POR state: 000Ch 13 12 11 10 9 8 Bits 15:0 www.national.com 6 5 4 3 2 1 0 0 0 0 0 1 1 0 0 Res Name POR 7 0 0 0 0 0 0 0 0 Reserved. This address is read only. 68 ADC10D1000/1500 19.0 Physical Dimensions inches (millimeters) unless otherwise noted NOTES: UNLESS OTHERWISE SPECIFIED REFERENCE JEDEC REGISTRATION MS-034, VARIATION BAL-2. 292-Ball BGA Thermally Enhanced Package Order Number ADC10D1000/1500CIUT NS Package Number UFH292A 69 www.national.com ADC10D1000/1500 Low Power, 10-Bit, Dual 1.0/1.5 GSPS or Single 2.0/3.0 GSPS ADC Notes For more National Semiconductor product information and proven design tools, visit the following Web sites at: www.national.com Products Design Support Amplifiers www.national.com/amplifiers WEBENCH(R) Tools www.national.com/webench Audio www.national.com/audio App Notes www.national.com/appnotes Clock and Timing www.national.com/timing Reference Designs www.national.com/refdesigns Data Converters www.national.com/adc Samples www.national.com/samples Interface www.national.com/interface Eval Boards www.national.com/evalboards LVDS www.national.com/lvds Packaging www.national.com/packaging Power Management www.national.com/power Green Compliance www.national.com/quality/green Switching Regulators www.national.com/switchers Distributors www.national.com/contacts LDOs www.national.com/ldo Quality and Reliability www.national.com/quality LED Lighting www.national.com/led Feedback/Support www.national.com/feedback Voltage References www.national.com/vref Design Made Easy www.national.com/easy www.national.com/powerwise Applications & Markets www.national.com/solutions Mil/Aero www.national.com/milaero PowerWise(R) Solutions Serial Digital Interface (SDI) www.national.com/sdi Temperature Sensors www.national.com/tempsensors SolarMagicTM www.national.com/solarmagic PLL/VCO www.national.com/wireless www.national.com/training PowerWise(R) Design University THE CONTENTS OF THIS DOCUMENT ARE PROVIDED IN CONNECTION WITH NATIONAL SEMICONDUCTOR CORPORATION ("NATIONAL") PRODUCTS. NATIONAL MAKES NO REPRESENTATIONS OR WARRANTIES WITH RESPECT TO THE ACCURACY OR COMPLETENESS OF THE CONTENTS OF THIS PUBLICATION AND RESERVES THE RIGHT TO MAKE CHANGES TO SPECIFICATIONS AND PRODUCT DESCRIPTIONS AT ANY TIME WITHOUT NOTICE. NO LICENSE, WHETHER EXPRESS, IMPLIED, ARISING BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. TESTING AND OTHER QUALITY CONTROLS ARE USED TO THE EXTENT NATIONAL DEEMS NECESSARY TO SUPPORT NATIONAL'S PRODUCT WARRANTY. EXCEPT WHERE MANDATED BY GOVERNMENT REQUIREMENTS, TESTING OF ALL PARAMETERS OF EACH PRODUCT IS NOT NECESSARILY PERFORMED. NATIONAL ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR BUYER PRODUCT DESIGN. BUYERS ARE RESPONSIBLE FOR THEIR PRODUCTS AND APPLICATIONS USING NATIONAL COMPONENTS. PRIOR TO USING OR DISTRIBUTING ANY PRODUCTS THAT INCLUDE NATIONAL COMPONENTS, BUYERS SHOULD PROVIDE ADEQUATE DESIGN, TESTING AND OPERATING SAFEGUARDS. EXCEPT AS PROVIDED IN NATIONAL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, NATIONAL ASSUMES NO LIABILITY WHATSOEVER, AND NATIONAL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY RELATING TO THE SALE AND/OR USE OF NATIONAL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. LIFE SUPPORT POLICY NATIONAL'S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein: Life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. National Semiconductor and the National Semiconductor logo are registered trademarks of National Semiconductor Corporation. All other brand or product names may be trademarks or registered trademarks of their respective holders. Copyright(c) 2011 National Semiconductor Corporation For the most current product information visit us at www.national.com National Semiconductor Americas Technical Support Center Email: support@nsc.com Tel: 1-800-272-9959 www.national.com National Semiconductor Europe Technical Support Center Email: europe.support@nsc.com National Semiconductor Asia Pacific Technical Support Center Email: ap.support@nsc.com National Semiconductor Japan Technical Support Center Email: jpn.feedback@nsc.com IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI's terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI's standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Audio www.ti.com/audio Communications and Telecom www.ti.com/communications Amplifiers amplifier.ti.com Computers and Peripherals www.ti.com/computers Data Converters dataconverter.ti.com Consumer Electronics www.ti.com/consumer-apps DLP(R) Products www.dlp.com Energy and Lighting www.ti.com/energy DSP dsp.ti.com Industrial www.ti.com/industrial Clocks and Timers www.ti.com/clocks Medical www.ti.com/medical Interface interface.ti.com Security www.ti.com/security Logic logic.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense Power Mgmt power.ti.com Transportation and Automotive www.ti.com/automotive Microcontrollers microcontroller.ti.com Video and Imaging RFID www.ti-rfid.com OMAP Mobile Processors www.ti.com/omap Wireless Connectivity www.ti.com/wirelessconnectivity TI E2E Community Home Page www.ti.com/video e2e.ti.com Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright (c) 2011, Texas Instruments Incorporated