The Fluke Ti5xFT and Ti4xFT models
feature everything needed for virtually any
thermography task.
All Fluke FlexCam Thermal Imagers come
standard with the patent-pending Fluke
IR-Fusion® Technology fusing visual (visible
light) images with infrared images.
SmartView IR analysis and reporting
software is included with each purchase
along with free software upgrades for
the life of your product.
The Ti4xFT models feature 160 x 120
detectors and temperature sensitivity
(NETD) down to 0.08 °C (80 mK) in the
higher end model.
The Ti5xFT models feature 320 x 240
detectors and temperature sensitivity
(NETD) down to 0.05 °C (50 mK) in the
higher end model.
Choose Fluke FlexCam Thermal Imagers
when you need industry leading thermal
sensitivity for high resolution, ultra
high-quality images.
Typical applications:
Troubleshooting—Pinpointing the location of
specific problems in equipment and systems.
Preventive/predictive maintenance
Identify electrical and mechanical problems
before they cause failure.
Industrial maintenance—Check whether
repairs have been performed correctly.
Process monitoring—Real-time observa-
tion to ensure efficient and safe operations.
Quality controlExamine prototypes and
refine thermal management designs.
Research and development—Quantify
heat patterns to improve product designs
(Ti5XFT models).
Electronic design—Circuit board analysis
(Ti5XFT models).
Technical Data
The experts’ choice for
problem solving and
preventive/predictive
maintenance
Fluke Ti5xFT and
Ti4xFT FlexCam®
Thermal Imagers
Ti55FT Ti50FT Ti45FT Ti40FT
High resolution, low noise VOx
detector for high quality images 320 x 240 160 x 120
Temperature range to cover broad
industrial applications
-20 °C to
+600 °C (-4 °F
to 1112 °F)
-20 °C to
+350 °C (-4 °F
to 662 °F)
-20 °C to
+600 °C (-4 °F
to 1112 °F)
-20 °C to
+350 °C (-4 °F
to 662 °F)
High temperature option 1200 °C
(2192 °F)
High thermal sensitivity for viewing even
the smallest temperature differences
0.05 °C at
30 °C (50 mK)
0.07 °C at
30 °C (70 mK)
0.08 °C at
30 ° C (80 mK)
0.09 °C at
30 ° C (90 mK)
180 ° articulating flexible lens to
view images in every situation
Choice of 3 interchangeable lenses to
cover every application*
Large 5 inch high contrast color LCD
for a clear picture independent of
lighting conditions
Fully radiometric for detailed
temperature analysis and tracking
SmartFocus for best image quality and
accurate temperature measurements
Windows CE based menu structure
for ease of use
Personalized instrument set-up for
multiple person use
CompactFlash memory cards to store
over 1000 IR images plus fully
radiometric temperature data
SmartView reporting and analysis
software included
AutoCapture for making intermittent
problems visible
On-board analysis functions
User defined text annotations for
simplified reporting
Built-in visible (visual) light camera
IR-Fusion blending thermal and
visible light images
IR/Visible Alarm function
Laser pointer for easy targeting
Flash and torch light for high quality
images in dark environments
Features
*10 mm and 54 mm lenses are optional and are only available at time of initial order.
2 Fluke Corporation Ti5XFT and Ti4XFT Thermal Imagers with IR-Fusion
Detailed specifications
Fluke Ti55FT Fluke Ti50FT Fluke Ti45FT Fluke Ti40FT
Imaging performance
Field of view (FOV)* 23° horizontal x 17° vertical
Spatial resolution (IFOV)* 1.30 mrad 2.60 mrad
Min focus distance* 0.15 m (5.9 in)
Thermal sensitivity (NETD) 0.05 °C at 30 °C (50 mK) 0.07 °C at 30 °C (70 mK) 0.08 °C at 30 °C (80mK) 0.09 °C at 30 °C (90mK)
Detector data acquisition/
image frequency
60 Hz/60 Hz 30 Hz/30 Hz
Focus SmartFocus; one finger continuous focus (manual)
IR digital zoom 2x, 4x, 8x 2x 2x
Detector type 320 x 240 Focal Plane Array, Vanadium Oxide (VOx)
Uncooled Microbolometer
160 x 120 Focal Plane Array, Vanadium Oxide (VOx)
Uncooled Microbolometer
Spectral band 8 µm to 14 µm
Digital image enhancement Automatic full time enhanced
On camera operating
modes
Full thermal, full visual light or merged
thermal-visual images.
Picture-in-Picture
Full thermal, full visual light or merged thermal-visual
images. Picture-in-Picture
Visible light camera 1280 x 1024 pixels, full color
Visible light digital zoom 2x, 4x 2x 2x
Temperature measurement
Calibrated temperature
range
-20 °C to 600 °C (-4 °F to
1112 °F) in three ranges
Range one =-20 °C to
100 °C (-4 °F to 212 °F)
Range two = -20 °C to
350 °C (32 °F to 662 °F)
Range three = 250 °C to
600 °C (482 °F to 1112 °F)
-20 °C to 350 °C (-4 °F
to 662 °F) in two ranges
Range one = -20 °C to
100 °C (-4 °F to 212 °F)
Range two = -20 °C to
350 °C (32 °F to 662 °F)
-20 °C to 600 °C (-4 °F
to 1112 °F) in three ranges
Range one = -20 °C to
100 °C (-4 °F to 212 °F)
Range two = -20 °C to
350 °C (32 °F to 662 °F)
Range three = 250 °C to
600 °C (482 °F to 1112 °F)
-20 °C to 350 °C (-4 °F
to 662 °F) in two ranges
Range one = -20 °C to
100 °C (-4 °F to 212 °F)
Range two = -20 °C to
350 °C (32 °F to 662 °F)
Optional—High temperature Up to 1200 °C (2192 °F)
Range 4 = 500 °C to
1200 °C (932 °F to 2192
°F)
Accuracy ± 2 °C or 2 % (whichever is greater)
Measurement modes Centerpoint, center box
(area min/max, average),
moveable spots/boxes,
user defined field/text
annotations, automatic hot
and cold point detection,
visible color alarm above
and below
Centerpoint, center box
(area min/max, average)
Centerpoint, center box
(area min/max, average),
moveable spots/boxes,
user defined field/text
annotations, automatic
hot and cold point
detection, visible color
alarm above and below
Centerpoint, center box
(area min/max, average)
Emissivity correction 0.1 to 1.0 (0.01 increments)
Image presentation
Digital display 13 cm (5 in) diagonal large high-resolution digital display
LCD backlight Sunlight readable color LCD
Video output RS170 EIA/NTSC or CCIR/PAL composite video
Palettes Grayscale, grayscale inverted, blue red, high contrast, hot metal, ironbow, amber, amber inverted
Optical lenses
54 mm telephoto lens High precision Germanium lens
Field of view (FOV): 9° horizontal x 6° vertical
Spatial resolution (IFOV): 0.47 mrad Spatial resolution (IFOV): 0.94 mrad
Min focus distance: 0.6 m (1.97 ft)
General specifications
3 Fluke Corporation Ti5XFT and Ti4XFT Thermal Imagers with IR-Fusion
Fluke Corporation
PO Box 9090, Everett, WA U.S.A. 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2007-2009 Fluke Corporation.
Specifications subject to change without notice.
Printed in U.S.A. 4/2009 2674273 D-EN-N Rev D
Fluke. Keeping your world
up and running.®
Ordering information
FLK-Ti40FT-20 IR FlexCam Thermal Imager with IR-Fusion
FLK-Ti45FT-20 IR FlexCam Thermal Imager with IR-Fusion
FLK-Ti50FT-20 IR FlexCam Thermal Imager with IR-Fusion
FLK-Ti55FT-20 IR FlexCam Thermal Imager with IR-Fusion
Included with product
Heavy duty carrying case, 2 rechargeable
battery packs, battery charger, ac adapter
(for Ti45FT and Ti55FT only), video cable,
512 MB compact flash card, compact flash
card reader and USB cable, PCMCIA
compact flash card reader, neck strap,
printed getting started guide, SmartView
reporting and analysis, software on CD,
complete user manual on CD
Fluke Ti55FT Fluke Ti50FT Fluke Ti45FT Fluke Ti40FT
Optical lenses (continued)
10.5 mm wide angle lens High precision Germanium lens
Field of view (FOV): 42° horizontal x 32° vertical
Spatial resolution (IFOV): 2.45 mrad Spatial resolution (IFOV): 4.9 mrad
Min focus distance: 0.3 m (0.98 ft)
Image and data storage
Storage medium Compact flash card stores over 1000 IR images (1 GB card standard)
File formats supported 14 bit measurement data included. Exportable Images: bmp, gif, jpg, png, tiff;
Data formats: comma separated (csv), tab separated (txt).
Interface and software
Interface Compact flash card reader included
Software SmartView; Full analysis and reporting software included
Laser
Classification Class II
Laser targeting Laser dot visible on screen when blending thermal and visible image
Controls and adjustments
Set-up controls Date/time, temperature units C/F, language, scale, LCD intensity (high/normal/low)
Image controls Level, span, auto adjust (continuous/manual)
On-screen indicators Battery status, target emissivity, background temperature and realtime clock
Power
Battery type Li-Ion smart battery, rechargeable, field-replaceable (two included)
Battery operating time Two hours continuous operation (per battery)
Battery charging Two bay intelligent charger powered via ac outlet
Continuous ac operation AC adapter 110/220 V ac,
50/60 Hz
AC adapter 110/220 V ac,
50/60 Hz
Power saving Automatic shutdown and sleep modes (user specified)
Environmental and mechanical design
Operating temperature -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature -40 °C to +70 °C (-40 °F to 158 °F)
Relative humidity Operating and storage 10 % to 95 %, non-condensing
Water and dust resistant IP54
Weight (including batteries) 1.95 kg (4.3 lb)
Camera size (H x W x D) 162 mm x 262 mm x 101 mm (6.5 in x 10.5 in x 4.0 in)
Other
Warranty Two-years
*Standard 20 mm Germanium lens
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Fluke:
TI55FT-10/20/54