Part #:
Revision:
Loudness @ 2 FT
Frequency
Low -1750 ± 500 Hz, High - 2900 ± 500 Hz
62 to 81 dB(A) Typ.
Loudness @ Min Vdc
60 dB(A) min @ 2 Feet and 6 Vdc
6 to 16 VDC
Recommended hole size is 1.25"(31.75mm). Thread front will fit standard 30mm(1.181") hole.
Operating Temperature
Loudness @ Max Vdc
69 dB(A) min @ 2 Feet and 16 Vdc
Current Draw
Housing Material
Voltage Rating
6-27mA
Duty Cycle (%)
Panel Mounting
-40° to +85° C
6/6 Nylon, Color: Black
-30° to +65° C
Storage Temperature
50
4411 South High School Road, Indianapolis, Indiana 46241 U.S.A · Phone: (317) 612-1000 Fax: (317) 612-1010
www.mallory-sonalert.com
ROHS Compliant
Used to attach part to panel. The max recommended torque is 10 in-lbs.
2.1 oz (60g)
Approved with use of ACC03.
Please contact factory.
NEMA 3R,4X, & 12
Knurled Nut
Weight (Typical)
Dimensions:
Options
Inches (mm)
5 Functions: Continuous -, Slow Pulse @ 0.5 - 2.5 PPS - High or Low Frequency, Warble
Specifications:
Medium
Sound Level Category
Mode of Operation
Not for Use in New Designs- See SCE Multi-Tone Panel Alarms
SC616WXYR
C
Sales Outline Drawing
The red and black leads control the several
functions. A logic 'Low' is a voltage less
than 1/3 of supply voltage. A logic 'High' is
a voltage greater than 1/2 supply voltage.
A red or black input lead left unconnected is
considered an open state.
Black
Low
High
Low
Open
Open
Open
Red
High
Open
Open
High
Low
Open
Off
High Continuus
Low Continuous
High Pulse
Low Pulse
Warble
Function
Mode
Control Wire
Truth Table
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Mallory Sonalert:
SC616WXYR