G2RV
The World's First Industrial Slim Relay
Large plug-in terminals for reliable connection.
LED indicator and mechanical flag to check operation.
Transparent housing enables checking relay condition.
Slim outline to save space.
Push-in terminals and accessories for easy wiring.
Model Number Structure
Model Number Legend
1. Auxiliary Type Designation
SL: Slim relay and socket combination
2. Wire Connection
7: Screw terminals
5: Push-in terminals
3. Relay LED
0: Without LED
4. Relay Pushbutton
0: Without pushbutton
5. Input Voltage
Note: LED indicator available on socket.
Ordering Information
List of Models
Relay and Socket Combinations
1234 5
G2RV-SL @ @ @ - @
Classification Enclosure rating Input voltage Type of connection Contact form
SPDT
Plug-in terminals General-purpose Unsealed AC/DC Screw terminals G2RV-SL700
Push-in terminals G2RV-SL500
Input voltage Screw terminals Push-in terminals
12 VDC G2RV-SL700-12 VDC G2RV-SL500-12 VDC
24 VDC G2RV-SL700-24 VDC G2RV-SL500-24 VDC
24 VAC/DC G2RV-SL700-24 VAC/DC G2RV-SL500-24 VAC/DC
48 VAC/DC G2RV-SL700-48 VAC/DC G2RV-SL500-48 VAC/DC
110 VAC G2RV-SL700-110 VAC G2RV-SL500-110 VAC
230 VAC G2RV-SL700-230 VAC G2RV-SL500-230 VAC
2Slim Relay G2RV
Specifications
Input Ratings
Contact Ratings
Note: P level: λ60 = 0.1 x 10-6/operation
Characteristics
Note: Values in the above table are the initial values.
Rated voltage Rated current*1 Must operate
voltage
Must release
voltage
Power consumption Input voltage
AC DC % of rated voltage AC (VA)
Approx.
DC (mW)
Approx.
% of rated voltage
50 Hz 60 Hz
12 VDC --- --- 27.2 mA 80% 10% --- 300 mW ±10%
24 VDC --- --- 13.3 mA --- 300 mW
24 VAC/DC 21.1 mA 22.5 mA 13.0 mA 0.5 VA 300 mW
48 VAC/DC 8.5 mA 9.0 mA 5.2 mA 0.4 VA 250 mW
110 VAC 7.1 mA 7.5 mA --- 0.8 VA ---
230 VAC 7.3 mA 7.9 mA --- 1.7 VA ---
*1) Rated currents are measured at 23 degrees Celsius (ambient)
Number of poles 1 pole
Load Resistive load
(cosφ = 1)
Inductive load
(cosφ = 0.4, L/R = 7 ms)
Rated load 6 A at 250 VAC;
6 A at 30 VDC
2.5 A at 250 VAC;
2 A at 30 VDC
Rated carry current 6 A
Max. switching voltage 400 VAC, 125 VDC
Max. switching current 6 A
Max. switching power 1,500 VA
180 W
500 VA
60 W
Failure rate (reference value) 10mA at 5VDC (P level)
Item 1 pole
Contact resistance 100 mΩ max.
Operate (set) time 20 ms max.
Release time 40 ms max.
Max. operating frequency Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 4,000 VAC, 50/60 Hz for 1 min between coil and contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.50 mm single amplitude (1.0 mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.50 mm single amplitude (1.0 mm double amplitude)
Shock resistance Destruction: 1,000 m/s2
Malfunction: 200 m/s2 when energized; 100 m/s2 when not energized
Endurance Mechanical: 5,000,000 operations min.
Electrical : 100,000 Typical; NO 70,000 operations min. ; NC 50,000 operations min.
Ambient temperature Operating: –40°C to 55°C (with no icing or condensation)
Ambient humidity Operating: 5% to 85%
Weight Approx. 35 g
Overvoltage category III
Pollution degree 2
Contact material AgSnIn
Creepage distance 7.0 mm
Clearance distance 5.5 mm
Slim Relay G2RV 3
Approved Standards
UL 508 (File No. E41643)
IEC/VDE (EN 61810)
Model Contact form Coil ratings Contact ratings Operations
G2RV-SL Series SPDT 12 to 48 VDC
24 to 230 VAC
250 VAC 6 A (Resistive Load)
30 VDC 6 A (Resistive Load)
400 VAC 2 A (Resistive Load)
6,000
Contact form Coil ratings Contact ratings Operations
1 pole 12, 24 VDC
24, 48 VAC/DC
110, 230 VAC
250 VAC 6 A (Resistive Load)
30 VDC 6 A (Resistive Load)
400 VAC 2 A (Resistive Load)
50,000
50,000
6,000
4Slim Relay G2RV
Engineering Data
Endurance Switching capacity of DC resistive load
Typical Operating and Release Time
Accessories
PLC Interface (for G2RV-SL700 series only)
List of Models
Specifications Electrical schematic P2RVC-O-8-F
10
100
1000
02 4
Switching current (A)
Endurance (x 103 operations)
250VAC resistive load
30VDC resistive load
30VDC inductive load
(L/R=7ms)
250VAC inductive load
(cos ϕ = 0.4)
6
0,1
1,0
10,0
20 60 100 140 180 220
Switching voltage (VDC)
DC Breaking Current (A)
Model number Operating time (typical) Release time (typical)
G2RV-SL7@@/5@@ DC12 5 ~ 7 ms 5 ~ 8 ms
G2RV-SL7@@/5@@ DC24 5 ~ 7 ms 6 ~ 9 ms
G2RV-SL7@@/5@@ AC/DC24 5 ~ 7 ms 17 ~ 22 ms
G2RV-SL7@@/5@@ AC/DC48 5 ~ 7 ms 22 ~ 30 ms
G2RV-SL7@@/5@@ AC110 12 ~ 15 ms 22 ~ 30 ms
G2RV-SL7@@/5@@ AC230 12 ~ 15 ms 22 ~ 30 ms
Model number Description Connection
P2RVC-8-O-F PLC Output Interface for 8x
G2RV-SL700-series
PNP - type
Ribbon cable connector
10 Pole, IEC603/1
Input Rated voltage 30 VAC/VDC max.
Current capacity 0.5 A per channel
2.0 A total current, power supply
terminal
Characteristics Ambient
temperature
Operating: 0 to 55°C
Storage: 20 to 85°C
Overvoltage
category
III
Pollution degree 2
Slim Relay G2RV 5
Cables for PLC Interface P2RVC-8-O-F
P2RV-4-@@@C
Cable to connect CJ1 to 4 x P2RVC-8-O-F
List of Models
4x10 pole IDC mounting to 4 x P2RVC-8-O-F
Technical data
P2RV-A@@@C
Cable, single sided 10 pole IDC connector, to connect to P2RVC-8-O-F
List of Models
40 pole IDC mounting to P2RVC-8-O-F
Technical data
Model number Cable length
P2RV-4-100C 1.0 m
P2RV-4-200C 2.0 m
P2RV-4-300C 3.0 m
P2RV-4-500C 5.0 m
A
A1 A2 A3 A4 A5 A6 A7 A8 A9 A100B1B2B3B4 B5 B6 B7 B8 B9 B100C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10
B C D
40 38 36 34 32 30 28 26 22 24 39 37 35 33 31 29 27 25 21 23 20 18 16 14 12 10 8 6 2 4 19 17 15 13 11 9 7 5 1 3
40 pole IDC mounting to Omron PLC CJ1-OD232
Cable length as indictad
by model number.
@@@ = length in centimeters
Split into 4 sections
Length = 30 cm
40 Pole
B
A
D
C
Control line AWG26/0.14 mm2, tin-plated copper
Diameter cable 10.6 mm (one end splits into 4 sections: A, B, C, D
Operating voltage 60 VDC
Continuous current per signal wire 0.5 A
Max. total current, 4 bytes, each 1.0 A
Test voltage 0.5 KV, 50 Hz, 1 min
Operating temperature range -20°C to +50°C
Model number Cable length
P2RV-A100C 1.0 m
P2RV-A200C 2.0 m
P2RV-A300C 3.0 m
P2RV-A500C 5.0 m
WHITE
GREY
PURPLE
BLUE
GREEN
YELLOW
ORANGE
RED
BROWN
BLACK
10
9
8
7
6
5
4
3
2
1
Open end
Cable length as indictad
by model number.
@@@ = length in centimeters
Outer isolation removed
Length = 30 cm
10 Pole
Control line AWG26/0.14 mm2, tin-plated copper
Diameter cable 6.8 mm
Operating voltage 60 VDC
Continuous current per signal wire 0.5 A
Max. total current 1.0 A
Test voltage 0.5 KV, 50 Hz, 1 min
Operating temperature range -20°C to +50°C
6Slim Relay G2RV
P2RV-@@@C-SIM S7/@00
Cables to connect Siemens S7/300 or S7/400 to 4 x P2RVC-8-O-F
List of Models
Single Relays for Maintenance
Model Number Legend
1. Number of Poles
1: 1 pole
2. Terminals
S: Push-In
3. Relay LED
Blank: Without LED
4. Relay Pushbutton
Blank: Without pushbutton
5. Contact Material
Blank: AgSnIn
6. Rated Coil Voltage
11 VDC, 21 VDC, and 48 VDC
List of Models
Model number Cable length PLC type Configuration
P2RV-200C-SIM S7/300 2.0 m Siemens S7/300
4x1 Byte
P2RV-250C-SIM S7/300 2.5 m
P2RV-300C-SIM S7/300 3.0 m
P2RV-500C-SIM S7/300 5.0 m
P2RV-200C-SIM S7/400 2.0 m Siemens S7/400
4x1 Byte
P2RV-250C-SIM S7/400 2.5 m
P2RV-300C-SIM S7/400 3.0 m
P2RV-500C-SIM S7/400 5.0 m
12345
6
G2RV-@ - @ @ @ - @- @
Model number Replacement for
G2RV-1-S DC11 G2RV-SL7@@/5@@ DC12
G2RV-1-S DC21 G2RV-SL7@@/5@@ DC24
G2RV-SL7@@/5@@ AC/DC24
G2RV-1-S DC48 G2RV-SL7@@/5@@ AC/DC48
G2RV-SL7@@/5@@ AC110
G2RV-SL7@@/5@@ AC230
Slim Relay G2RV 7
Cross bars
Model Number Legend
1. Number of Poles 2. Color
020: 2 poles R: Red
030: 3 poles S: Blue
040: 4 poles B: Black
100: 10 poles
200: 20 poles
List of Models
@ select color: R = Red, S=Blue, B=Black
Specification
Plastic Labels for G2RV Sockets
Labels (Stickers) for G2RV Sockets
Model number Poles Quantity Color
P2RVM-020@2 60 pcs / box (minimum order)
Red (R)
Blue (S)
Black (B)
P2RVM-030@3 60 pcs / box (minimum order)
P2RVM-040@4 60 pcs / box (minimum order)
P2RVM-100@10 20 pcs / box (minimum order)
P2RVM-200@20 20 pcs / box (minimum order)
Max current
(EN60947-7-1 section 8.3.3 / 1991)
32A
Max. Voltage 400 VAC
Max. Voltage
when cutting Cross-bar without using separation
plate or end-bracket
250 VAC
12
P2RVM -@ @
Model number Box quantity Color
R99-15 for G2RV 5 sheets × 120 labels =
600 labels (minimum order)
White
Model number Box quantity Color
R99-16 for G2RV 10 sheets × 484 labels =
4,840 labels (minimum order)
White
8Slim Relay G2RV
Separating Plates
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Complete Unit
G2RV-SL700
Model number Quantity Description
P2RV-S 50 plates
(minimum order)
Provides isolation between
adjacent relays to achieve
400 V isolation.
12
11
14
A1
A2
24 V DC
Terminal Arrangement/
Internal Connections
(Top View)
12
11
14
A1
A2
12 V DC
Terminal Arrangement/
Internal Connections
(Top View)
12
11
14
A1
A2
Other Coil Voltage
Terminal Arrangement/
Internal Connections
(Top View)
Five,
M2.5 × 6
6.2 max.
99.2
7.188.9
26.1
47.2
70.9
83
106.7 max.
92.7 max.
35
Input circuit
Slim Relay G2RV 9
G2RV-SL500
Single Relay
G2RV-1-S
12
11
14
A1
A2
24 V DC
Terminal Arrangement/
Internal Connections
(Top View)
12
11
14
A1
A2
12 V DC
Terminal Arrangement/
Internal Connections
12
11
14
A1
A2
Other Coil Voltage
Terminal Arrangement/
Internal Connections
(Top View)
6.2 max.
99.2
88.9 7.1
24.6
46
69.8
82.9
106.7 max.
97.4 max.
35
Input circuit
A2
A1
12
11
14
Terminal Arrangement/
Internal Connections
(Bottom View)
30.5 max.
3.5
0.5 2.4
1.8
5.2 max.
5.04 5.04
322
33 max.
16.2
Input circuit
10 Slim Relay G2RV
Installation
Tools
G2RV-SL700 series: Flat-Blade screwdriver should be used for mounting and / or releasing cables.
G2RV-SL500 series: Flat-Blade screwdriver should be used for mounting stranded wires without ferrules and / or releasing cables.
Applicable Screwdriver
Flat-blade, Parallel-tip, 2.5 mm diameter (3.0 mm max.)
Examples: FACOM AEF.2.5×75E (AEF. 3×75E)
VESSEL No. 9900-(-)2.5×75 (No. 9900-(-)3×100)
WAGO 210-119
WIHA 260/2.5×40 (260/3×50)
*Chamfering the tip of the driver improves insertion when used as an exclusive tool.
Applicable Wires
Applicable Wire Sizes
G2RV-SL700 Series
Box clamp technology
G2RV-SL500 Series
Push-in technology
Flat-blade, Parallel-tip
Flat-blade, Flared-tip
2.5 dia. (3.0 mm max.)
Cannot be used.
Wire type Applicable wire size Stripping length
Stranded without ferrules 0.5 - 2.5 mm27mm
Stranded with ferrules and plastic collar 0.5 - 2.5 mm27mm
Stranded with ferrules without plastic collar 0.5 - 2.5 mm27mm
Solid 0.5 - 2.5 mm27mm
Wire type Applicable wire size Stripping length
Stranded without ferrules 0.5 - 2.5 mm212 mm
Stranded with ferrules and plastic collar 0.5 - 2.5 mm212 mm
Stranded with ferrules without plastic collar 0.5 - 2.5 mm212 mm
Solid 0.5 - 2.5 mm212 mm
Slim Relay G2RV 11
Wiring
Use wires of the applicable sizes specified above. The length of the exposed conductor should be 7 mm for a G2RV-SL700 series, 12 mm for a
G2RV-SL500 series.
Wiring Procedure for G2RV-SL500 series
Wiring
Insert the exposed conductor into the connection hole.
No other tools are required.
Note: In case of wiring stranded wires without ferrules screwdriver
should be inserted before inserting the wire.
Screwdriver should be removed after fully insertion of the wire.
Removing
Insert the specified screwdriver into the release hole.
Removing wire.
Removing screwdriver.
7 mm
Fig. 1 Exposed Conductor Length
12 mm
G2RV-SL700
G2RV-SL500
Screwdriver hole
Wire connection hole
Wire
12 Slim Relay G2RV
Precautions
Precautions for Connection
Do not move the screwdriver up, down, or from side to side while it
is inserted in the hole. Doing so may cause damage to internal
components (e.g., deformation of the clamp spring or cracks in the
housing) or cause deterioration of insulation.
Do not insert the screwdriver at an angle. Doing so may break the
side of socket and result in a short-circuit.
Do not insert two or more wires in the hole. Wires may come in
contact with the spring causing a temperature rise or be subject to
sparks.
Insert the screwdriver along the hole wall as shown below.
If lubricating liquid, such as oil, is present on the tip of screwdriver,
the screwdriver may fall out resulting in injury to the operator.
Insert the screwdriver into the bottom of the hole. It may not be
possible to connect cables properly if the screwdriver is inserted
incorrectly.
General Precautions
Do not use the product if it has been dropped on the ground.
Dropping the product may adversely affect performance.
Confirm that the socket is securely attached to the mounting track
before wiring. If the socket is mounted insecurely it may fall and
injure the operator.
Ensure that the socket is not charged during wiring and
maintenance. Not doing so may result in electric shock.
Do not pour water or cleansing agents on the product. Doing so
may result in electric shock.
Do not use the socket in locations subject to solvents or alkaline
chemicals.
Do not use the socket in locations subject to ultraviolet light (e.g.,
direct sunlight). Doing so may result in markings fading, rust,
corrosion, or resin deterioration.
Do not dispose the product in fire.
Removing from Mounting Rail
To remove the socket from the mounting rail, insert the tip of
screwdriver in the fixture rail, and move it in the direction shown
below.
Screwdriver
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.