PRO mode
•PRO mode appears after the MODE key is pressed for 4
sec. in RUN mode.
Setting item
Factory setting
Description
Shift
setting
[Shift amount 15 %]
Shift amount can be selected from 0 to 80 % in
the limit teaching. Select 0 % when it is desired
to set the present incident light intensity as a
threshold value.
External
input
setting [Emission halt]
External input can be selected from emission
halt,limitteaching[+],limitteaching[-],full-auto
teaching, ECO (Note 1), 2-point teaching or
emission amount test. When setting the incident
light intensity test “ ”, output turns ON /
OFF every 100ms when the rate of incident
light intensity and threshold value is less than
half of the set shift amount (for example, when
the rate of incident light intensity and threshold
value is within ±10 % for 20 % of shift amount)
at external input.
Threshold
value-storing
setting mode
(Note 2)
[OFF]
Threshold value set at the limit teaching,
full-auto teaching or 2-point teaching by
external input is stored. When selecting
Auto in the emission amount setting
mode, the set emission amount level is
also stored.
Threshold
value
follow-up
cycle
setting
(Note 3)
[OFF]
When incident light intensity exceeds threshold
value, this mode can change the threshold value
with each set cycle depending on variations of the
incident light intensity. The follow-up shift amount
is same as the one set in the shift setting mode.
However, the threshold value is not stored.
GETA
function
setting
(Note 4, 5)
[OFF]
Variations can be reduced by correcting the
presentincidentlightintensityineachamplier
to a target value. Target value to offset incident
light intensity can be selected from 0 to 2,000
by 100 unit each. For example, if the target
value is set to 2,000 when the incident light
intensity is 1,500, the incident light intensity
becomes 2,000.
ECO
setting [OFF]
It is possible to light up / turn off the digital
display. When ECO setting mode is ON, the
display turns off in 20 sec. approx. in RUN
mode. To light up the display again, press any
key for 2 sec. or more.
Digital display
inversion
setting
[OFF] Digital display can be inverted.
Threshold
value
margin
setting
[OFF]
Margin for threshold value to the present
incident light intensity can be checked. When
there is no margin, it is possible to make the
digital display blink.
: Set to “OFF”: does not function
.
:
Green blinks
.
:
Red blinks
.
:
Red and green blink
.
:
When conducting limit teaching or 2-point
teaching by external input, in case the rate of reference
incident light intensity and threshold value after teaching
is 200% or more, or in case it is less than half of the shift
amount, output turns ON / OFF every 100 ms. (Note 6)
Setting
copy [NO]
Thesettingsofthemastersideampliercan
becopiedtotheslavesideamplier.
For details, refer to “Setting copy function”.
Reset [NO] Returns to default settings (factory settings.)
Setting copy function
•Thiscancopythesettingsofthemastersideamplierto
theslavesideamplier.
•Be sure to use the setting copy function between the
identical models (Between FX-101□ models or FX-102□
models).
This function cannot be used between different
models.
•Only one sensor can be connected on slave side with a
master side sensor for the setting copy function.
•Threshold value, output operation setting, timer
operation setting, timer setting, light-emitting amount
setting, shift setting, external input setting, threshold
value margin setting, ECO setting, digital display
inversion setting, and threshold value margin setting
can be copied.
<Setting procedures>
Setthesettingcopymodeofthemastersideamplierto
“Copy sending ON”, and press the MODE key so that
“ ” is shown on the digital display and the
sensor is in copy ready state. For the setting method,
refer to “Operation guide”.
Turnoffthemastersideamplier.
Connectthemastersideamplierwiththeslaveside
amplierasshownbelow.
Turnonthemastersideamplierandtheslaveside
amplieratthesametime.(Note)
“ ” is shown on the green digital display of the master
sideamplierand4-digitcodeisshownonthered
digital display of it, then the copying starts. During copy
communication, “ ” is shown on the green digital
displayoftheslavesideamplier,andtheongoingcopy
communication indicator (“ ”→“ ”→“ ”→
“ ”→“ ”→“ ”→“ ”→“ ”) is displayed on
the red digital display.
When the copying is completed, “ ” is shown on the
greendigitaldisplayoftheslavesideamplier,whilethe
4-digitcode(thesamecodeasthemastersideamplier)
is shown on the red digital display of it.
Turnoffthepowerofthemastersideamplierandthe
slavesideamplieranddisconnectthewire.
* Ifcopyingthesettingstoanotheramplierrepeatedly,followthesteps
to .
Note: Take care that if the power is not turned on at the same time, the
setting contents may not be copied.
<To cancel the setting copy mode of the master side amplier>
Whiletheslavesideamplierisdisconnected,turnon
thepowerofthemastersideamplier.
Press the MODE key for 2 sec. approx.
Master side amplifier
Slave side amplifier
Color code of cable with connector
+
–
12 to 24V DC
±10 %
(Brown) +V
(Black) Input
(White) External input
(Blue) 0 V
(Brown) +V
(Black) Input
(White) External input
(Blue) 0 V
PRECAUTIONS FOR PROPER USE Refer to the “Operation Guide” on our website for details pertaining to
operatinginstructionsfortheamplier.
Notes: 1) When ECO is selected at the external input setting mode, key
operation on the main body is invalid during external input.
2) This mode is not indicated unless any of “ ”, “ ”,
“ ” or “ ” is set at the external input setting mode.
3)
If the incident light intensity becomes “300” or less, the follow-up
operation stops. In that condition, threshold value [digital display
(green)] blinks. This function can be used when thru-beam type or
retroreectivetypeberisappliedtothisproduct.Ifreectivetypeber
is applied, the function cannot be used depending on use conditions.
4) If MODE key is pressed in RUN mode when GETA function is
used, the incident light intensity before setting GETA function is
displayed on the red digital display for 2 sec. approx.
5) When GETA function is used in saturation of incident light intensity
(4,000 or more,) “ ” is indicated on the red digital display.
Correction value is up to 4,000.
6) This mode does not operate unless any of “ ”, “ ” or
“ ” is set at the external input setting mode.
72
Fiber
Selection
Guide
Choose
by model
Choose
by shape/
application
Viewing
new models
Fiber
Dimensions
Thru-beam
Type
Retroreective
Type
Reective
Type
Others
Amplifiers
FX-500
series
FX-100
series
INDEX
Fiber
Options
Fibers
Super
Quality
Threaded
Type
Cylindrical
Type
Sleeve
Flat
Type
Small
Spot
Narroe
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical-
resistant
Heat-
resistant
Vacuum-
resistant
Liquid Leak /
Liquid Detection
New product
introduction
Tough
Fiber
Earlier models
comparison
table