9363 Triad - 300V Power-Limited Tray Cable For more information please call 1-800-Belden1 See Put-ups and Colors Color Code Chart : ICEA Table E1.pdf Description: 22 AWG triads stranded (7x30) tinned copper conductors, twisted triads, PVC insulation, overall Beldfoil shield (100% coverage), PVC jacket. PHYSICAL CHARACTERISTICS: CONDUCTOR: Number of Triads 1 Total Number of Conductors 3 AWG 22 Stranding 7x30 Conductor Material TC - Tinned Copper INSULATION: Insulation Material PVC - Polyvinyl Chloride Insulation Diameter .062 in. OVERALL CABLING: Overall Cabling Color Code Chart : Number 1 Color Black & White & Red OUTER SHIELD: Outer Shield Material Trade Name Beldfoil(R) Outer Shield Type Tape Outer Shield Material Aluminum Foil-Polyester Tape Outer Shield %Coverage 100 % OUTER SHIELD DRAIN WIRE : Outer Shield Drain Wire AWG 22 Outer Shield Drain Wire Stranding 7x30 Outer Shield Drain Wire Conductor Material TC - Tinned Copper OUTER JACKET: Page 1 of 3 9363 Triad - 300V Power-Limited Tray Cable Outer Jacket Material PVC - Polyvinyl Chloride Outer Jacket Nominal Wall Thickness .037 in. Outer Jacket Ripcord Yes OVERALL NOMINAL DIAMETER: Overall Nominal Diameter .208 in. MECHANICAL CHARACTERISTICS: Operating Temperature Range -30C To +105C UL Temperature Rating 105C Bulk Cable Weight 26 lbs/1000 ft. Max. Recommended Pulling Tension 29 lbs. Min. Bend Radius (Install) 2 in. APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE: APPLICABLE STANDARDS: NEC/(UL) Specification PLTC, ITC, CMG CEC/C(UL) Specification CMG EU CE Mark (Y/N) Yes EU RoHS Compliant (Y/N) Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 FLAME TEST: UL Flame Test UL1685 FT4 Loading C(UL) Flame Test FT4 IEEE Flame Test 1202 ICEA Flame Test T-29-520 SUITABILITY: Suitability - Indoor Yes Suitability - Outdoor Yes Suitability - Burial Yes Sunlight Resistance Yes PLENUM/NON-PLENUM: Plenum (Y/N) N ELECTRICAL CHARACTERISTICS: Nom. Inductance .21 H/ft Nom. Capacitance Conductor to Shield @ 1 KHz 45 pF/ft Nom. Capacitance Conductor to Conductor @ 1 KHz 26 pF/ft Nom. Conductor DC Resistance @ 20 Deg. C 15 Ohms/1000 ft Page 2 of 3 9363 Triad - 300V Power-Limited Tray Cable Nominal Outer Shield DC Resistance 60 Ohms/1000 ft Max. Operating Voltage - UL 300 Max. Recommended Current 3.8 Amps per conductor @ 25C PUT-UPS AND COLORS: Item Description 9363 060U1000 3 #22 PVC SHLD PVC 9363 060U500 3 #22 PVC SHLD PVC Revision Number: 1 Put-Up (ft.) U1000 Ship Weight (lbs.) 26 Jacket Color CHROME U500 13.5 CHROME Notes Revision Date: 09-20-2005 (c) 2005 Belden Wire & Cable Company All Rights Reserved. Although Belden Electronics Division ("Belden") makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden CDT Electronics Division believes this product to be in compliance with the following environmental regulations: California Proposition 65 Consent Judgment For Wire & Cable Mfgs.(San Francisco Superior Court Nos. 312962 And 320342); EU RoHS (Directive 2002/95/EC, 27-Jan-2003);Material manufactured prior to the compliance date may still be in stock at Belden facilities and in our Distributor's inventory. EU ELV (Directive 2000/53/EC, 18-Sept-2000); EU WEEE (Directive 2002/96/EC, 27-Jan-2003); And EU BFR (Directive 2003/11/EC, 6-Feb-2003). The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information and belief at the date of its publication. The information provided in the Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden CDT Electronics Division declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3