G4W PCB Power Relay
■Ratings
●Coil
Note 1. The rated current and coil resistance are measured at a coil
temperature of 23°C with a tolerance of ±15%.
2.The operating characteristics are measured at a coil temperature of
23°C.
3.The “Max. voltage” is the maximum voltage that can be applied to the
relay coil.
●Contacts
■Characteristics
Note: The above values are initial values.
*1. The contact resistance was measured with 1 A at 5 VDC with a
fall-of-potential method.
*2. The insulation resistance was measured with a 500 VDC Megger Tester
applied to the same parts as those for checking the dielectric strength.
*3. This value was measured at a switching frequency of 120 operations/min.
■Engineering Data
Item
Rated
voltage
Rated
current
(mA)
Coil
resistance
(Ω)
Must
operate
voltage
(V)
Must
release
voltage
(V)
Max.
voltage
(V)
Power
consumption
(mW)
% of rated voltage
12 VDC 66.7 180 80%
max.
10%
min.
130%
(at 23°C)
Approx.
0.8 W
24 VDC 33.3 720
100 VDC 8 12,500
Contact form SPST-NO (1a) DPST-NO (2a)
Load
Item
Resistive load
(cos
φ
= 1)
Inductive load
(cos
φ
= 0.4)
Resistive load
(cos
φ
= 1)
Inductive load
(cos
φ
= 0.4)
Contact material Ag-Alloy (Cd free)
Rated load 15 A at 250 VAC
15 A at 24 VDC
10 A at 250 VAC
7.5 A at 24 VDC
10 A at 250 VAC
10 A at 24 VDC
7.5 A at 250 VAC
5 A at 24 VDC
Rated carry
current 15 A 10 A
Max. switching
voltage 250 VAC, 125 VDC
Max. switching
current 15 A 10 A
Contact resistance *1 30 m
Ω
max.
Operate time 20 ms max.
Release time 5 ms max.
Max. operating
frequency
Mechanical 18,000 operations/hr
Electrical 1,800 operations/hr
Insulation resistance *2 100 M
Ω
max.
Dielectric
strength
Between coil and
contacts 4,000 VAC, 50/60 Hz for 1 min
Between contacts of
the same polarity 1,500 VAC, 50/60 Hz for 1 min
Between contacts of
different polarities 2,000 VAC, 50/60 Hz for 1 min
Impulse
withstand voltage
Between coil and
contacts 10,000 V
Insulation
distance
Between coil and
contacts Clearance: 8 mm, Creepage: 8 mm
Vibration
resistance
Destruction 10 to 55 to 10 Hz, 0.75 mm single
amplitude (1.5 mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.75 mm single
amplitude (1.5 mm double amplitude)
Shock resistance Destruction 1,000 m/s
2
Malfunction 150 m/s
2
Durability
Mechanical 5,000,000 operations min.
(at 18,000 operations/hr)
Electrical 100,000 operations min.
(rated load, at 1,800 operations/hr)
Failure rate (P level) (reference value) *3 100 mA at 5 VDC
Ambient operating temperature -25°C to 55°C (with no icing or condensation)
Ambient operating humidity 5% to 85%
Weight Approx. 29 g
●Maximum Switching Capacity
SPST-NO (1a) DPST-NO (2a)
●Durability
SPST-NO (1a) AC Load DPST-NO (2a) AC Load
●Durability
SPST-NO (1a) DC Load DPST-NO (2a) DC Load
●Ambient Temperature vs.
Maximum Coil Voltage
●Ambient Temperature vs.
Must Operate and Must
Release Voltage
G4W-2212P-US-TV5
Note: The maximum coil voltage refers to
the maximum value in a varying
range of operating power voltage,
not a continuous voltage.
●Shock Malfunction
Switching voltage (V)
100
50
30
15
10
5
3
1
0.5
0.3
0.1
1 3 5 10 30 50 100 300 500 1,000
AC
inductive
load
(cosφ = 0.4)
Switching current (A)
AC resistive load
DC resistive load
DC inductive load
(L/R = 7 ms)
Switching voltage (V)
100
50
30
10
5
3
1
0.5
0.3
0.1
1 3 5 10 30 50 100 300 500 1,000
Switching current (A)
AC resistive load
AC
inductive
load
(cosφ = 0.4)
DC resistive load
DC inductive load
(L/R = 7 ms)
1,000
500
300
100
50
30
100 2 4 6 8 10 12 14 15 16
Switching current (A)
(AC Load)
250 VAC resistive load (cosφ = 1)
250 VAC inductive load (cosφ = 0.4)
Durability (x10
4
operations)
1,000
500
300
100
50
30
100 2 4 6 7.5 8 10 12 14 16
Switching current (A)
(AC Load)
250 VAC inductive load (cosφ = 0.4)
250 VAC resistive load (cosφ = 1)
Durability (x10
4
operations)
1,000
500
300
100
50
30
100 2 4 6 8 10 12 14 16
Switching current (A)
(DC Load)
24 VDC inductive load (L/R = 7 ms)
24 VDC resistive load
110 VDC inductive load (L/R = 7 ms)
110 VDC resistive load
Durability (x10
4
operations)
1,000
500
300
100
50
30
100 2 4 6 8 10 12 14 16
Switching current (A)
(DC Load)
24 VDC inductive load (L/R = 7 ms)
24 VDC resistive load
110 VDC inductive load (L/R = 7 ms)
110 VDC resistive load
Durability (x104 operations)
Ambient temperature (°C)
200
180
160
140
130
120
110
100
80
0
0 20 30 40 50 55 60 70 80 90
Maximum coil voltage (%)
Sample:
G4W-2212P-US-TV5
Number of Relays: 5 pcs
100
80
60
40
20
0
−40 −20 0 20 40 60 80
Ambient temperature (°C)
Must operate voltage
Must release voltage
Must-operate/must-release voltage (On the basis of rated voltage) (%)
Z'
Z
Z
Z'
Shock direction
Unit: m/s2
Y
Y
Y'
Y'
X
X
X'
X'
1,000
1,000
1,000
1,000
1,000
1,000
700
Energized
800
600
400
200
200
400
600
800
800
G4W-1112P-US-TV8
Number of Relays: 5 pcs
Test Conditions: Shock is applied in ±X, ±Y, and ±Z directions three
times each with and without energizing the Relays
to check the number of contact malfunctions.
Standard value: 150 m/s2