6
0.5mm and 1mm Pitch Connectors For FPC/FFC
FH12 Series
Features
1. Ease of Use and Space Savings
Only one finger or 6.9N (Newtons) of force is required to
lock Hirose’s rotational actuator (flip-lock) as compared
to using 2 fingers and 39.2N to close a FFC/FPC
connector from our competition.
The Flip-Lock design also allows customers to place 2
or more connectors side by side as there is no need to
waste additional board space for a side latch.
2. Strengthened Lock Lever
The standard Flip-Lock requires only 2.0mm height
above the board. A strengthened lock lever is available
which only requires an additional 0.4mm.
3. Supports Thin FPC (0.18mm)
Hirose does not require double-sided FPC to have any
additional strengthening plate or stiffener and can therefore
support a thickness of as little as 0.18mm +/- 0.05.
4.
Hirose Ensures Reliability
Hirose’s patented half tuning fork contacts maintain the
required normal force without relying on the connector
housing. With our competitor’s conventional products
the housing walls support the contact force, which does
not provide for long-term reliability.
5. Prevention of Solder Bridge
Excess solder cavity absorbs excessive solder and
avoids solder bridging.
6. Three different assembly types
FH12 is offered in Top & Bottom Contact and Vertical
Mount and offered in both a 0.5mm contact pitch as well
as a 1.0mm contact pitch (bottom contact only).
Applications
Notebook computers, printers, PDAs, digital cameras and
other compact devices for interconnecting the main circuit
board with the LCD, HDD or other device.
Rotating One-touch Mechanism
q
w
e
Flip-lock
7
Product Specifications
Rating
Current rating: 0.4A DC
Operating Temperature Range:_40 to +70ç (Note 1)
Storage Temperature Range:_10 to +50ç (Note 2)
Voltage rating: 50V AC
Operating Humidity Range:Relative humidity, 90% max.
Storage Humidity Range:Relative humidity, 90% max.
(Not dewed) (Not dewed)
Applicable FPC t=0.3±0.05 Solder plating(Note 3) t=0.18 ± 0.05 for FH12F-*S-0.5SH
Note 1: Includes temperature rise caused by current flow.
Note 2: The term "storage" refers to products stored for long period of time prior to mounting and use. Operating Temperature Range and
Humidity range covers nonconducting condition of installed connectors in storage, shipment or during transportation.
Note 3: When FPC is gold plated, the connector contacts should be also gold plated: Select the (05) specification.
Material
Part Material Finish Remarks
Insulator Polyamide Color : Beige UL94V-0
PPS Color : Deep brown
Contact Phosphor bronze Solder plating –––––––
Macal Fittings Brass Solder plating
Ordering Information
FH12 A - 10 (4) - S A - 0.5 SH (05)
qerw yt u i o
qSeries Name : FH12
wBlank : standard type
A : Top contact type
S : Type with strengthed lock lever
F : Type with 0.18mm FPC End Thickness
eStandard type : Number of contacts
Eccentric type :
Number of contacts in 0.5mm housing
rStandard type : Blank
Eccentric type : Number of contacts
tContact alignment: Single
yEccentric direction:
Blank : standard type
A : Eccentric type
uContacts Pitch : 0.5mm, 1mm
iContact type
SH
:
SMT horizontal mounting type
SV
:
SMT vertical mounting type
Plating specification
No symbol: Solder plating
(05): Gold plating
o
1. Insulation resistance 500M ohms minimum 100V DC
2. Withstanding voltage No flashover or insulation breakdown. 150V AC/1 minute
3. Contact resistance 50m ohms maximum 1mA
4.
Durability (Insertion/withdrawal)
Contact resistance: 50m ohms maximum 20 cycles
No damage, cracks, or parts dislocation.
No electrical discontinuity of 1µs or more Frequency: 10 to 55 Hz, single amplitude of 0.75 mm,
5. Vibration Contact resistance: 50m ohms maximum. 2 hours in each of the 3 directions.
No damage, cracks, or parts dislocation.
No electrical discontinuity of 1µs or more Acceleration of 490 m/s2, 11 ms duration,
6. Shock Contact resistance: 50m ohms maximum.
sine half-wave waveform, 3 cycles in each of the 3 axis.
No damage, cracks, or parts dislocation.
Contact resistance: 50m ohms maximum.
7.
Humidity(Steady state)
Insulation resistance: 50M ohms maximum.
96 hours at temperature of 40ç and humidity of 90% to 95%
No damage, cracks, or parts dislocation.
Contact resistance: 50m ohms maximum. 5 cycles under conditions as follows;
8. Temperature Cycle Insulation resistance: 50M ohms maximum. Temperature: -40
ç
/15 to 35
ç
/85
ç
/15 to 35
ç
,
No damage, cracks, or parts dislocation. Time: 30 /5 max. /30 /5 max.(minutes)
9.
Resistance
to
Soldering heat
No deformation of Reflow: At the recommended temperature profile
components affecting performance. Manual soldering: 350±5ç for 3 seconds
Item Specification Conditions
8
BSeries Configuration
FH12- ** S-0.5SH
Number of contacts
6, 10, 11, 12, 13, 14,
15, 16, 17, 18, 19, 20,
22, 24, 25, 26, 28, 30,
32, 33, 34, 36, 40, 45,
50, 53
FH12F- ** S-0.5SH
Number of contacts
6, 10, 12, 13, 14, 15, 16,
18, 20, 22, 24, 26, 28,
30, 32, (33), 34, 36, 40
FH12S- ** S-0.5SH
Number of contacts
30, 40, 45, 50, 53
Standard
FH12-
**
S-1SH
Eccentric FH12- ** (**) S-1SH
Standard
Number of contacts 5, 6, 7, 8, 9, 11,
16, 22, 26
Eccentric
Number of contacts 4, 6, 8, 10, 11,
14, 19, 24
FH12- ** S-1SV
Number of contacts
6, 7, 8, 16, 20, 22,
24
Pitch
0.5mm
1mm
Bottom Contact Type
Type with Strengthened Lock Lever
Type with 0.18mm FPC End Thickness
Top Contact Type Vertical mounting Type
P.13
P.12
P.14
P.18
P.19
FH12- ** S-0.5SV
Number of contacts
10, 12, 13, 15, 16, 17,
18, 20, 22, 24, 26, 30,
32, 33, 34, 36, 40, 45,
49, 50
P.16
FH12A- ** S-0.5SH
Number of contacts
10, 12 ,15, 16, 18, 20,
22, 24, 26, 28, 29, 30,
32, 33, 34, 36, 40, 42,
45, 50
P.15
FPC conductive
surface
FPC conductive surface
(bottom side)
FPC conductive surface
(bottom side)
9
BConnector Operating Instructions & Precautions
Bottom Contact Type (common for 0.5mm/1mm)
Operating Instruction Precautions for Use
1. FPC/FFC Insertion
1Lift up the lock lever.
(The lock is released.)
The lock lever can be simply operated by flicking it
up with the fingernail of the thumb or forefinger.
2. FPC/FFC Removal
1Lift up the lock lever and pull out the FPC after the
lock is released.
2Insert the FPC with the conductive surface fac-
ing down.
Insert the FPC so that it is perpendicular with
respect to the connector.
1Avoid grasping the lock lever with your fingers or
hooking the lever (especially with your fingernail).
The part is small and thin and could be damaged.
3Press down the lock lever
When the FPC is partially inserted or there is an
extreme insertion offset, the lock level will engage
poorly or not at all. Should this happen, remove the
FPC with the removal method of 2-(1) and perform
the operation of 1-(1) again.
2Please ensure that the FPC is properly inserted
into the connector insertion slot. Failing to insert
the FPC properly could cause FPC breakage and
conduction faults.
3Due to the structure of the connectors, they do not
have strong resistance to upward pulling; there-
fore, support the FPC when a pulling force is
applied to it.
10
Top Contact Type
Operating Instruction Precautions for Use
1. FPC/FFC Insertion
1Lift up the lock lever.
(The lock is released.)
The lock lever can be simply operated by flicking it
up with the fingernail of the thumb or forefinger.
2. FPC/FFC Removal
1Lift up the lock lever and pull out the FPC after the
lock is released.
2Insert the FPC with the conductive surface fac-
ing up. Fully insert the FPC into the insertion
slot of the connector.
1Avoid forcing the lock lever upward when the FPC
is not inserted. The part is small and thin and could
be damaged.
3Firmly press down the lock lever on both sides.
The design is such that pressing only on one side
will not engage the lock, but incomplete pressing
will result in locking failure.
2Avoid operation with only one side of the lock
lever at the time of locking. The use of only one
side will cause a locking fault.
3Avoid forced pulling of the FPC. Forced pulling will
cause the FPC to become disconnected or dam-
aged.
FPC/FFC contacto surface
11
Vertical Mounting Type
Operating Instruction Precautions for Use
1. FPC/FFC Insertion
1Check that the lock lever is standing upright. If the
lock lever has fallen to the side, stand it upright.
2. FPC/FFC Removal
1Press the lock lever upward and pull out the FPC
after the lock is released. This operation is easily
done by inserting your thumb and forefinger.
2Insert the FPC vertically with the conductive side
(i.e., wire connection portion) of the FPC facing
away from the lock lever. Fully insert the FPC into
the insertion slot.
1Avoid grasping and twisting the lock lever with your
fingers or forcefully pressing the lock lever without
a cable inserted.
3Press down the upright standing lock lever in the
direction of rotation.
2Please ensure that the FPC is fully inserted into
the connector insertion slot. Failing to insert the
FPC properly could cause FPC breakage and
conduction faults.
FPC/FFC contacto surface
FPC/FFC contacto surface
12
0.5mm Pitch Bottom Contact Type
2
0.2
0.5
0.821.2
1.85
5.6
4.6
4.8
2
()
FPC/FFC Contact Surface
1.3
2.1
3.1
Mated Cross-sectional Diagram
Note 1 : Products are packaged in embossed tape. (2,000 pcs./reel)
Please order in multiples of 2,000.
Note : If there is no problem with the connector height, we recommend the type with the
strengthened lock lever (FH12S-*S-0.5SH).
Standard type connector height: 2 mm
Connector height of type with strengthened lock lever: 2.4 mm
D
Unit:mm
CL No.Part Number 586-0582-5
586-0522-3
586-0600-5
586-0704-0
586-0549-0
586-0533-0
586-0523-6
586-0531-4
586-0606-1
586-0530-1
586-0534-2
586-0524-9
586-0532-7
586-0521-0
586-0692-3
586-0576-2
586-0612-4
586-0525-1
586-0681-7
586-0520-8
586-0617-8
586-0526-4
586-0527-7
586-0528-0
586-0529-2
586-0595-7
FH12-06S-0.5SH
FH12-10S-0.5SH
FH12-11S-0.5SH
FH12-12S-0.5SH
FH12-13S-0.5SH
FH12-14S-0.5SH
FH12-15S-0.5SH
FH12-16S-0.5SH
FH12-17S-0.5SH
FH12-18S-0.5SH
FH12-19S-0.5SH
FH12-20S-0.5SH
FH12-22S-0.5SH
FH12-24S-0.5SH
FH12-25S-0.5SH
FH12-26S-0.5SH
FH12-28S-0.5SH
FH12-30S-0.5SH
FH12-32S-0.5SH
FH12-33S-0.5SH
FH12-34S-0.5SH
FH12-36S-0.5SH
FH12-40S-0.5SH
FH12-45S-0.5SH
FH12-50S-0.5SH
FH12-53S-0.5SH
Number of Contacts
6
10
11
12
13
14
15
16
17
18
19
20
22
24
25
26
28
30
32
33
34
36
40
45
50
53
A B
02.5
04.5
05.0
05.5
06.0
06.5
07.0
07.5
08.0
08.5
09.0
09.5
10.5
11.5
12.0
12.5
13.5
14.5
15.5
16.0
16.5
17.5
19.5
22.0
24.5
26.0
06.1
08.1
08.6
09.1
09.6
10.1
10.6
11.1
11.6
12.1
12.6
13.1
14.1
15.1
15.6
16.1
17.1
18.1
19.1
19.6
20.1
21.1
23.1
25.6
28.1
29.6
C
07.1
09.1
09.6
10.1
10.6
11.1
11.6
12.1
12.6
13.1
13.6
14.1
15.1
16.1
16.6
17.1
18.1
19.1
20.1
20.6
21.1
22.1
24.1
26.6
29.1
30.6
03.57
05.57
06.07
06.57
07.07
07.57
08.07
08.57
09.07
09.57
10.07
10.57
11.57
12.57
13.07
13.57
14.57
15.57
16.57
17.07
17.57
18.57
20.57
23.07
25.57
27.07
2
2
2
2
2
Note
Note
Note
Note
Note
2
13
Note: Products are packaged in embossed tape. (2,000 pcs./reel)
Please order in multiples of 2,000.
D
Unit:mm
CL No.Part Number 586-0667-6
586-0640-0
586-0665-0
586-0642-5
586-0691-0
FH12S-30S-0.5SH
FH12S-40S-0.5SH
FH12S-45S-0.5SH
FH12S-50S-0.5SH
FH12S-53S-0.5SH
Number of Contacts
30
40
45
50
53
A B
14.5
19.5
22.0
24.5
26.0
18.1
23.1
25.6
28.1
29.6
C
19.1
24.1
26.6
29.1
30.6
15.57
20.57
23.07
25.57
27.07
0.5mm Pitch Bottom Contact Type with Strengthened Lock Lever
FPC/FFC Contact Surface
Mated Cross-sectional Diagram
2
C
B
1.2 2 0.8
0.2
0.5
A
(4.8)
2.1
3.1 1.3
2.25
2.4
D4.6
5.6
()
() ()
()
14
Applicable FPC end thickness : 0.18±0.05
0.5mm Pitch Bottom Contact Type with 0.18mm FPC End Thickness
0.2
0.5
A
0.821.2
B
C
D
1.85
2
5.6
4.6
4.8
FPC Contact Surface
3.15
2.15
1.25
Mated Cross-sectional Diagram
()
()()
()
()
Note: Products are packaged in embossed tape. (2,000 pcs./reel)
Please order in multiples of 2,000.
D
Unit:mm
CL No.Part Number 586-0672-6
586-0709-4
586-0653-1
586-0629-7
586-0655-7
586-0680-4
586-0673-9
586-0626-9
586-0636-2
586-0630-6
586-0632-1
586-0627-1
586-0643-8
586-0628-4
586-0705-3
--------------------
586-0677-0
586-0656-0
586-0635-0
FH12F-06S-0.5SH
FH12F-10S-0.5SH
FH12F-12S-0.5SH
FH12F-13S-0.5SH
FH12F-14S-0.5SH
FH12F-15S-0.5SH
FH12F-16S-0.5SH
FH12F-18S-0.5SH
FH12F-20S-0.5SH
FH12F-22S-0.5SH
FH12F-24S-0.5SH
FH12F-26S-0.5SH
FH12F-28S-0.5SH
FH12F-30S-0.5SH
FH12F-32S-0.5SH
FH12F-33S-0.5SH
FH12F-34S-0.5SH
FH12F-36S-0.5SH
FH12F-40S-0.5SH
Number of Contacts
6
10
12
13
14
15
16
18
20
22
24
26
28
30
32
33
34
36
40
A B
02.5
04.5
05.5
06.0
06.5
07.0
07.5
08.5
09.5
10.5
11.5
12.5
13.5
14.5
15.5
16.0
16.5
17.5
19.5
06.1
08.1
09.1
09.6
10.1
10.6
11.1
12.1
13.1
14.1
15.1
16.1
17.1
18.1
19.1
19.6
20.1
21.1
23.1
C
07.1
09.1
10.1
10.6
11.1
11.6
12.1
13.1
14.1
15.1
16.1
17.1
18.1
19.1
20.1
20.6
21.1
22.1
24.1
03.57
05.57
06.57
07.07
07.57
08.07
08.57
09.57
10.57
11.57
12.57
13.57
14.57
15.57
16.57
17.07
17.57
18.57
20.57
15
D E
Unit:mm
CL No.Part Number 586-0550-9
586-0696-4
586-0551-1
586-0552-4
586-0553-7
586-0554-0
586-0686-0
586-0555-2
586-0663-5
586-0725-0
586-0585-3
586-0556-5
586-0687-3
586-0570-6
586-0670-0
586-0662-2
586-0557-8
586-0698-0
586-0558-0
586-0559-3
FH12A-10S-0.5SH
FH12A-12S-0.5SH
FH12A-15S-0.5SH
FH12A-16S-0.5SH
FH12A-18S-0.5SH
FH12A-20S-0.5SH
FH12A-22S-0.5SH
FH12A-24S-0.5SH
FH12A-26S-0.5SH
FH12A-28S-0.5SH
FH12A-29S-0.5SH
FH12A-30S-0.5SH
FH12A-32S-0.5SH
FH12A-33S-0.5SH
FH12A-34S-0.5SH
FH12A-36S-0.5SH
FH12A-40S-0.5SH
FH12A-42S-0.5SH
FH12A-45S-0.5SH
FH12A-50S-0.5SH
Number of Contacts
10
12
15
16
18
20
22
24
26
28
29
30
32
33
34
36
40
42
45
50
A B
9.1
10.1
11.6
12.1
13.1
14.1
15.1
16.1
17.1
18.1
18.6
19.1
20.1
20.6
21.1
22.1
24.1
25.1
26.6
29.1
8.35
9.35
10.85
11.35
12.35
13.35
14.35
15.35
16.35
17.35
17.85
18.35
19.35
19.85
20.35
21.35
23.35
24.35
25.85
28.35
C
4.5
5.5
7.0
7.5
8.5
9.5
10.5
11.5
12.5
13.5
14.0
14.5
15.5
16.0
16.5
17.5
19.5
20.5
22.0
24.5
9.5
10.5
12.0
12.5
13.5
14.5
15.5
16.5
17.5
18.5
19.0
19.5
20.5
21.0
21.5
22.5
24.5
25.5
27.0
29.5
5.57
6.57
8.07
8.57
9.57
10.57
11.57
12.57
13.57
14.57
15.07
15.57
16.57
17.07
17.57
18.57
20.57
21.57
23.07
25.57
0.5mm Pitch Top Contact Type
FPC/FFC Contact Surface
Mated Cross-sectional Diagram
2
C
B
1.2 2 0.8
0.2
0.5
A
(4.8)
2.1
3.1 1.3
2.25
2.4
D4.6
5.6
()
() ()
()
Note 1 : Products are packaged in embossed tape. (2,000 pcs./reel)
Please order in multiples of 2,000.
Note : The design is such that the FPC/FFC protrudes on an upward angle so that other
parts can be mounted beneath the PFC/FFC. In view of this, please take note of the
gap at the top surface of the connector.
2
16
0.5mm Pitch Vertical mounting Type
(
0.15
)10.2
1F
A
B
C
D
E
3.8
(
Metalfittingdimension
)
3.6
5.5
1.75
4.25
(4.85)
0.5
1.4
2.15
0.5 2.5 0.5
Mated Cross-sectional Diagram
FPC/FFC Contact Surface
(
(
)
)
()
()
()
D E
Unit:mm
CL No.Part Number 586-0560-2
586-0615-2
586-0575-0
586-0561-5
586-0572-1
586-0601-8
586-0573-4
586-0562-8
586-0589-4
586-0563-0
586-0664-8
586-0564-3
586-0699-2
586-0565-6
586-0706-6
586-0641-2
586-0566-9
586-0567-1
586-0602-0
586-0568-4
FH12-10S-0.5SV
FH12-12S-0.5SV
FH12-13S-0.5SV
FH12-15S-0.5SV
FH12-16S-0.5SV
FH12-17S-0.5SV
FH12-18S-0.5SV
FH12-20S-0.5SV
FH12-22S-0.5SV
FH12-24S-0.5SV
FH12-26S-0.5SV
FH12-30S-0.5SV
FH12-32S-0.5SV
FH12-33S-0.5SV
FH12-34S-0.5SV
FH12-36S-0.5SV
FH12-40S-0.5SV
FH12-45S-0.5SV
FH12-49S-0.5SV
FH12-50S-0.5SV
Number of Contacts
10
12
13
15
16
17
18
20
22
24
26
30
32
33
34
36
40
45
49
50
A B
08.4
09.4
09.9
10.9
11.4
11.9
12.4
13.4
14.4
15.4
16.4
18.4
19.4
19.9
20.4
21.4
23.4
25.9
27.9
28.4
06.9
07.9
08.4
09.4
09.9
10.4
10.9
11.9
12.9
13.9
14.9
16.9
17.9
18.4
18.9
19.9
21.9
24.4
26.4
26.9
C
04.5
05.5
06.0
07.0
07.5
08.0
08.5
09.5
10.5
11.5
12.5
14.5
15.5
16.0
16.5
17.5
19.5
22.0
24.0
24.5
06.5
07.5
08.0
09.0
09.5
10.0
10.5
11.5
12.5
13.5
14.5
16.5
17.5
18.0
18.5
19.5
21.5
24.0
26.0
26.5
08.2
09.2
09.7
10.7
11.2
11.7
12.2
13.2
14.2
15.2
16.2
18.2
19.2
19.7
20.2
21.2
23.2
25.7
27.7
28.2
F
4
4
4
4
4
4
4
4
8
8
8
8
8
8
8
8
8
8
8
8
Note 1 : Products are packaged in embossed tape. (1,000 pcs./reel)
Please order in multiples of 1,000.
17
6
10
11
12
13
14
15
16
17
18
19
20
22
24
02.5
04.5
05.0
05.5
06.0
06.5
07.0
07.5
08.0
08.5
09.0
09.5
10.5
11.5
03.5
05.5
06.0
06.5
07.0
07.5
08.0
08.5
09.0
09.5
10.0
10.5
11.5
12.5
25
26
28
29
30
32
33
34
36
40
42
45
50
53
12.0
12.5
13.5
14.0
14.5
15.5
16.0
16.5
17.5
19.5
20.5
22.0
24.5
26.0
13.0
13.5
14.5
15.0
15.5
16.5
17.0
17.5
18.5
20.5
21.5
23.0
25.5
27.0
6
10
11
12
13
14
15
16
17
18
19
20
22
24
02.5
04.5
05.0
05.5
06.0
06.5
07.0
07.5
08.0
08.5
09.0
09.5
10.5
11.5
08.1
10.1
10.6
11.1
11.6
12.1
12.6
13.1
13.6
14.1
14.6
15.1
16.1
17.1
04.5
06.5
07.0
07.5
08.0
08.5
09.0
09.5
10.0
10.5
11.0
11.5
12.5
13.5
25
26
28
29
30
32
33
34
36
40
42
45
50
53
12.0
12.5
13.5
14.0
14.5
15.5
16.0
16.5
17.5
19.5
20.5
22.0
24.5
26.0
17.6
18.1
19.1
19.6
20.1
21.1
21.6
22.1
23.1
25.1
26.1
27.6
30.1
31.6
14.0
14.5
15.5
16.0
16.5
17.5
18.0
18.5
19.5
21.5
22.5
24.0
26.5
28.0
B
Recommended
FPC/FFC
dimensions and Land/Metal Mask dimensions
0.5mm Pitch Product
Dimension
Number
of Contacts
A B A B
Dimension
Number
of Contacts
Unit: mm
Dimension
Number
of Contacts
A B C
Dimension
Number
of Contacts
A B C
Unit: mm
Land / Metal Mask dimensionsFPC/FFC dimensions
0.5mm Pitch
Bottom Contact
Type
0.5mm Pitch
Top Contact
Type
C
0.5±0.1
0.5±0.05
A±0.05
B±0.07
0.35±0.03(FPC)
0.3±0.03(FFC)
3.5MIN
4.5MIN
B±0.1
C±0.1
A±0.05
0.5±0.05
0.3±0.03(Land)
0.25±0.0(Metal mask)
2.2±0.1
1.5±0.1
1.3±0.1
Recommended metal mask thickness : t=0.15
0.5mm Pitch
Vertical
Mounting Type
*Set the stiffener thickness to 0.188 (7.5mil) min.
0.8±0.1(Land)
0.65±0.05(Metal mask)
0.6
±
0.1(Land)
0.5
±
0.05(Metal mask)
0.5±0.1
0.5±0.05 0.3±0.05
A±0.05
B±0.07
0.35±0.03(FPC)
Recommended metal mask thickness : t=0.15
Even contact number Odd contact number
0.3±0.03(FFC)
2MIN
3MIN
0.5±0.05
1±0.05
1±0.05 1±0.05
A±0.1
B±0.05
1.8±0.1
1.8±0.1
0.8
±
0.1(Land)
0.65
±
0.05(Metal mask)
0.6
±
0.1(Land)
0.5
±
0.05(Metal mask)
0.5±0.05
1±0.05
1±0.05 1±0.05
A±0.1 No.1 contactNo.1 contact
B±0.05
1.8±0.1
1.8±0.1
1.5±0.1
1.5±0.1
4.5±0.1
1.5±0.1
1.5±0.1
4.5±0.1
10
12
13
15
16
17
18
20
22
24
04.5
05.5
06.0
07.0
07.5
08.0
08.5
09.5
10.5
11.5
05.5
06.5
07.0
08.0
08.5
09.0
09.5
10.5
11.5
12.5
26
30
32
33
34
36
40
45
49
50
12.5
14.5
15.5
16.0
16.5
17.5
19.5
22.0
24.0
24.5
13.5
15.5
16.5
17.0
17.5
18.5
20.5
23.0
25.0
25.5
Dimension
Number
of Contacts
A B A B
Dimension
Number
of Contacts
Unit: mm
10
12
13
15
16
17
18
20
22
24
06.5
07.5
08.0
09.0
09.5
10.0
10.5
11.5
12.5
13.5
04.5
05.5
06.0
07.0
07.5
08.0
08.5
09.5
10.5
11.5
26
30
32
33
34
36
40
45
49
50
14.5
16.5
17.5
18.0
18.5
19.5
21.5
24.0
26.0
26.5
12.5
14.5
15.5
16.0
16.5
17.5
19.5
22.0
24.0
24.5
Dimension
Number
of Contacts
A B A B
Dimension
Number
of Contacts
Unit: mm
Product Type
Types other than
those below
Types with an FPC end
thickness of 0.18 mm
C Dimension
0.3±0.05min
Stiffener thickness should be 0.188 mm (7.5 mil) min
0.18±0.05
18
Note 1: Products are packaged in embossed tape. (2,000 pcs. per reel)
Please order in multiples of 2,000.
Note 2: The 1mm version of FH12 is constructed by loading every other contact into the 0.5mm housing.
When a housing designed for an odd number of 0.5mm pitch contacts is used; the spacing from the
edge to the first contact on either side is the same as the distance between each contact, 1.0mm.
Hirose considers this design to be a standard-type 1.0mm connector.
Note 2: An eccentric-type connector using a housing designed for an even number of 0.5mm pitch contacts
and consequently one side has 1.5mm distance from the edge to the first contact. (See FPC/FFC
dimensional drawing on page 19) The part number for the eccentric type describes the size of the
0.5mm housing used and lists the number of 1.0mm pitch contacts in parentheses () as shown in the
above table.
D E
Unit:mm
CL No.Part Number 586-0591-6
586-0607-4
586-0535-5
586-0579-0
586-0540-5
586-0668-9
586-0536-8
586-0547-4
586-0592-9
586-0537-0
586-0538-3
586-0539-6
586-0541-8
586-0542-0
586-0543-3
586-0546-1
586-0548-7
FH12-05S-1SH
FH12-06S-1SH
FH12-07S-1SH
FH12-08S-1SH
FH12-09S-1SH
FH12-11S-1SH
FH12-16S-1SH
FH12-22S-1SH
FH12-26S-1SH
FH12-10(4)SA-1SH
FH12-14(6)SA-1SH
FH12-18(8)SA-1SH
FH12-22(10)SA-1SH
FH12-24(11)SA-1SH
FH12-30(14)SA-1SH
FH12-40(19)SA-1SH
FH12-50(24)SA-1SH
Number of Contacts
5
6
7
8
9
11
16
22
26
4
6
8
10
11
14
19
24
A B
04
05
06
07
08
10
15
21
25
03
05
07
09
10
13
18
23
08.6
09.6
10.6
11.6
12.6
14.6
19.6
25.6
29.6
08.1
10.1
12.1
14.1
15.1
18.1
23.1
28.1
C
09.6
10.6
11.6
12.6
13.6
15.6
20.6
26.6
30.6
09.1
11.1
13.1
15.1
16.1
19.1
24.1
29.1
06.07
07.07
08.07
09.07
10.07
12.07
17.07
23.07
27.07
05.57
07.57
09.57
11.57
12.57
15.57
20.57
25.57
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
Standard typeEccentric type
1mm Pitch Type Bottom Contact Type
(0.2)
(2.1)
(3.1)
(4.8)
(1.3)
2.3 E
FPC/FFC Contact Surface
D
1.0
A
0.821.2
B
C
1.85
2
5.6
4.6
Mated Cross-sectional Diagram
19
Note: Products are packaged in embossed tape. (1,000 pcs. per reel)
Please order in multiples of 1,000.
D E F
Unit:mm
CL No.Part Number 586-0605-9
586-0610-9
586-0593-1
586-0574-7
586-0634-7
586-0584-0
586-0594-4
FH12-06S-1SV
FH12-07S-1SV
FH12-08S-1SV
FH12-16S-1SV
FH12-20S-1SV
FH12-22S-1SV
FH12-24S-1SV
Number of Contacts
6
7
8
16
20
22
24
A B
09.9
10.9
11.9
19.9
23.9
25.9
27.9
08.4
09.4
10.4
18.4
22.4
24.4
26.4
C
05
06
07
15
19
21
23
08
09
10
18
22
24
26
09.7
10.7
11.7
19.7
23.7
25.7
27.7
4
4
4
8
8
8
8
1mm Pitch Vertical Mounting Type
(0.15)(0.2) 2
2F
A
B
C
D
E
3.8
(Metalfittingdimension)
3.6
5.5
(4.85)
(2.15)
(1.4)
(4.25)
(1.75)
1.0
0.5 2.5 0.5
Mated Cross-sectional Diagram
FPC/FFC Contact Surface
20
BRecommended FPC/FFC dimensions and Land/Metal Mask dimensions
1mm Pitch Product
Land / Metal Mask dimensionsFPC/FFC dimensions
1mm Pitch
Bottom Contact
Type
1mm Pitch
Vertical
Mounting Type
πSet the stiffener thickness to 0.188 (7.5mil) min.
Recommended metal mask thickness : t=0.15
Recommended metal mask thickness : t=0.15
5
6
7
8
9
11
16
22
26
04
05
06
07
08
10
15
21
25
06
07
08
09
10
12
17
23
27
1
1
1
1
1
1
1
1
1
4
6
8
10
11
14
19
24
03
05
07
09
10
13
18
23
05.5
07.5
09.5
11.5
12.5
15.5
20.5
25.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
Dimension
Number
of Contacts
A B C
Dimension
Number
of Contacts
A B C
Unit: mm
6
7
8
16
20
22
24
05
06
07
15
19
21
23
07
08
09
17
21
23
25
Dimension
Number
of Contacts
A B
Unit: mm
6
7
8
16
20
22
24
08
09
10
18
22
24
26
05
06
07
15
19
21
23
Dimension
Number
of Contacts
A B
Unit: mm
*Set the stiffener thickness to 0.188 (7.5mil) min.
5
6
7
8
9
11
16
22
26
04
05
06
07
08
10
15
21
25
10.6
11.6
12.6
13.6
14.6
16.6
21.6
27.6
31.6
07
08
09
10
11
13
18
24
28
4
6
8
10
11
14
19
24
03
05
07
09
10
13
18
23
10.1
12.1
14.1
16.1
17.1
20.1
25.1
30.1
06.5
08.5
10.5
12.5
13.5
16.5
21.5
26.5
Dimension
Number
of Contacts
A B C
Dimension
Number
of Contacts
A B C
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2
2
2
2
2
2
2
2
D D
Unit: mm
Standard Type
Eccentric Type
Eccentric Type
Standard Type
21
Note: 2,000 pcs. per reel
Unit:mm
BPackaging Specification
Embossed Carrier Tape Dimensions
Horizontal Type (Common to Bottom/Top Contact, 0.5mm/1mm Pitch)
A
Dimension
Number
of Contacts
16
16
16
24
24
24
24
24
24
24
24
24
24
24
6
10
11
12
13
14
15
16
17
18
19
20
22
24
B
----------
----------
----------
----------
----------
----------
----------
----------
----------
----------
----------
----------
----------
----------
C
07.5
07.5
07.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
D
16.5
16.5
16.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
A
Dimension
Number
of Contacts
24
24
32
32
32
32
32
32
44
44
44
44
44
44
25
26
28
29
30
32
33
34
36
40
42
45
50
53
B
----------
----------
28.4
28.4
28.4
28.4
28.4
28.4
40.4
40.4
40.4
40.4
40.4
40.4
C
11.5
11.5
14.2
14.2
14.2
14.2
14.2
14.2
20.2
20.2
20.2
20.2
20.2
20.2
D
24.5
24.5
32.5
32.5
32.5
32.5
32.5
32.5
44.5
44.5
44.5
44.5
44.5
44.5
Note: 2,000 pcs. per reel
Unit:mm
A
Dimension
Number
of Contacts
16
24
24
24
24
32
44
44
4
6
8
10
11
14
19
24
Eccentric Type
B
----------
----------
----------
----------
----------
28.4
40.4
40.4
C
07.5
11.5
11.5
11.5
11.5
14.2
20.2
20.2
D
16.5
24.5
24.5
24.5
24.5
32.5
44.5
44.5
1mm Pitch Bottom Contact Type
0.5mm Pitch Bottom/Top Contact Type
Standard Type
A
Dimension
Number
of Contacts
16
24
24
24
24
24
32
44
44
5
6
7
8
9
11
16
22
26
B
----------
----------
----------
----------
----------
----------
28.4
40.4
40.4
C
07.5
11.5
11.5
11.5
11.5
11.5
14.2
20.2
20.2
D
16.5
24.5
24.5
24.5
24.5
24.5
32.5
44.5
44.5
(2.0) Flat surface for placement
with Automatic equipment
22
Note: 1,000 pcs. per reel
Note: 1,000 pcs. per reel
Unit:mm
Vertical Mounting Type (Common to 0.5mm/1mm Pitch)
A
Dimension
Number
of Contacts
16
16
24
24
24
24
24
24
24
24
10
12
13
15
16
17
18
20
22
24
B
----------
----------
----------
----------
----------
----------
----------
----------
----------
----------
C
07.5
07.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
D
16.5
16.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
A
Dimension
Number
of Contacts
24
24
24
32
44
44
44
6
7
8
16
20
22
24
B
----------
----------
----------
28.4
40.4
40.4
40.4
C
11.5
11.5
11.5
14.2
20.2
20.2
20.2
D
24.5
24.5
24.5
32.5
44.5
44.5
44.5
A
Dimension
Number
of Contacts
24
32
32
32
44
44
44
44
44
44
26
30
32
33
34
36
40
45
49
50
B
----------
28.4
28.4
28.4
40.4
40.4
40.4
40.4
40.4
40.4
C
11.5
14.2
14.2
14.2
20.2
20.2
20.2
20.2
20.2
20.2
D
24.5
32.5
32.5
32.5
44.5
44.5
44.5
44.5
44.5
44.5
1mm Pitch Vertical mounting Type
0.5mm Pitch Vertical mounting Type
Unit:mm
(1.75) Flat surface for placement
with Automatic equipment
23
Reel Dimensions (Common to All Types)
BRecommended Temperature Profile
Applicable condition
Reflow method : IR reflow
Solder :
Paste type 63sn/37Pb (Flux content: 11wt%)
Test board : Glass epoxy 40801.6mm
Metal mask thickness : 0.15mm
This temperature profile is a recommendation
The temperature may be slightly changed according to the
solder paste type and amount.
End portion Mounting portion Lead portion (400mm min.)
Top cover tape
Blank portion
(10 pockets min.)
Embossed carrier tape
Blank portion
(10 pockets min.)
24
25
25
5
35
25
25
30
175
295
BFH12 Series FPC/FFC Construction (Recommended Specifications)
1. FFC FFC : Flexible Flat Cable
FPC : Flexible Printed Circuit
Material Name Material Thickness (µm)
2. FPC
3. Precautions
Material Name
Covering layer film
Cover adhesive
Surface treatment
Copper foil
Base adhesive
Base film
Reinforcement material adhesive
Stiffener
Material Thickness (µm)
1. This specification is a recommendation for the construction of the FH12 Series FPC and FFC (t=0.3 ±0.05).
2. For details about the construction, please contact the FPC/FFC manufacturers.
Note: Use of a thicker FFC results in a stiffer lock action and the lock is more easily released.
A factor that contributes to thicker FFC is the use of 250 µm stiffener which is thicker than the standard (188 µm) product. This
results in a total thickness of 357 µm.
When using FFC, control of FFC thickness becomes easy if you indicate to us the thickness of the stiffener.
*Real tolerance of thickness dimension is on the order of ±20 µm (275 to 315 µm)
35
30
12
30
188
295
Hard copper foil with tin plating
Adhesive
Polyester
Adhesive
Stiffener (Note)
Polyester type
Polyester type
Polyester type
Total
Polyamide 1 mil
Solder plating
Cu 1oz
Polyamide 1 mil
Heat-hardened adhesive
Polyamide 7 mil