SPECIFICATION
MODEL PLP-60-12 PLP-60-24 PLP-60-48
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT
CURRENT ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP TIME
VOLTAGERANGE Note.4
FREQUENCY RANGE
POWERFACTOR
EFFICIENCY(Typ.)
ACCURRENT
INPUT
INRUSHCURRENT(max.)
LEAKAGECURRENT
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERCURRENT Note.5
SHORTCIRCUIT
OVERVOLTAGE
12V 24V 48V
18~24V 36~48V
5A
0~5A
2.5A
0~2.5A
1.3A
0~1.3A
60W 60W 62.5W
4.5Vp-p 4.5Vp-p
1.875~2.5A
4.8Vp-p
0.975~1.3A
10%
3.0%
5.0%
1000ms/230VAC20 atfullload00ms/115VAC
90~264VAC
47~63Hz
PF 0.9at75~100%load,115VAC/230VAC
84% 88% 89%
15~18V 28~35V 57~63V
0.8A/115VAC0.4A/230VAC
42A/230VAC
<0.75mA /240VAC
Protectiontype: Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
-30~+70 (Refertooutputloadderatingcurve)
20~95%RH non-condensing
-40~+80 ,10~95%RH
0.03%/ (0~50 )
10~500Hz,2G12min./1cycle,periodfor72min.eachalongX, Y,Zaxes
583.3Khrsmin.MIL-HDBK-217F(25 )
101.6*50.8*29.6mm(L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor, direct connecting
to LED's is not suggested for models with "RIPPLE & NOISE" > 10% and using additional drivers is highly recommended.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
6. Heat sink HS1,HS2 can not be shorted.
7. Heat sink HS1 must have safety isolation distance with system case.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
0.16Kg;96pcs/16.4Kg/0.89CUFT
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Built-in active PFC function
Cooling by free air convection
Output current level adjustable
100% full load burn-in test
High
Suitable for built-in applications of LED lighting
2 years warranty
reliability
Features :
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SAFETY STANDARDS
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3.75KVACI/P-FG:1.88KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC/25 /70%RH
HARMONICCURRENT
EMSIMMUNITY
Complianceto EN55015
Complianceto ClassC( 75%load);EN61000-3-3
EN61000-3-2
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024,EN61547,lightindustrylevel,criteria A
EMICONDUCTION&RADIATION
3.75~5A
100~110%
Protectiontype: Shutdowno/pvoltage,re-powerontorecover
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
60WSingleOutputLEDPowerSupply PLP-60 series
FileName:PLP-60-SPEC2010-09-06
CONSTANTCURRENTOPERATIONVOLTAGE Note.5
9~12V
TUVEN61347-1,EN61347-2-13approved; esignrefertoUL60950-1d
SELV
http://store.iiic.cc/
MechanicalSpecification
FileName:PLP-60-SPEC2010-09-06
Unit:mm
Ta:25
DeratingCurve StaticCharacteristics
AMBIENTTEMPERATURE( )
LOAD(%)
-30 -25 -5 0 20 40 50 55 60 70
20
40
60
80
100
INPUTVOLTAGE(V)60Hz
90 100 125 135 145 155 165 175 180 200 230 264
100
90
80
70
60
50
40
LOAD(%)
(HORIZONTAL)
fosc:90KHz(115VAC)
120KHz(230VAC)
BlockDiagram
DETECTION
PWM&PFC
CIRCUIT
O.L.P.
EMIFILTER
RECTIFIERS
POWER
SWITCHING FILTER
&
RECTIFIERS +V
-V
I/P
FG
CONTROL
O.V.P.
&
O.C.P.
50
ACInputConnector(CN1):JST B3P-VHorequivalent
DCOutputConnector(CN2):JST B2P-VHorequivalent
PinNo.
PinNo.1
1
3 2
2
Assignment
AssignmentAC/L
+V
AC/N -V
NoPin
MatingHousing
MatingHousing
JST VHR
JST VHR
orequivalent
orequivalent
Terminal
Terminal
JST SVH-21T-P1.1
JST SVH-21T-P1.1
orequivalent
orequivalent
12V
Others
CN2
CN1
FS1
1
2
1
2
3
3.175
3.175
95.25
101.6
.
.
HS2HS1
SVR1
PLP-60 series
60WSingleOutputLEDPowerSupply
29.6
3max.
4- 3.2
44.45
50.8
1.HS1,HS2 can not be shorted.
2.HS1 must have safety isolation distance
with system case.
http://store.iiic.cc/
0 . 7 8
0 . 8 0
0 . 8 2
0 . 8 4
0 . 8 6
0 . 8 8
0 . 9 0
0 . 9 2
0 . 9 4
0 . 9 6
0 . 9 8
1 . 0 0
5 0 % 6 0 % 7 0 % 8 0 % 9 0 % 1 0 0 %
2 3 0 V
1 1 0 V
60
62
64
66
68
70
72
74
76
78
80
82
84
86
88
90
92
94
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
230V
110V
PLP-60seriespossesssuperiorworkingefficiencythatupto89%canbereachedinfieldapplications.
EFFICIENCY (%)
LOAD
PowerFactorCharacteristic
Powerfactorwillbehigherthan0.9whenoutputloadingis75%orhigher.
EFFICIENCY vsLOAD(48VModel)
ConstantCurrentMode
PF
LOAD
TherearetwomajorkindsofLEDdrivemethod"directdrive"and"withLEDdriver".
A typicalLEDpowersupplymayeitherworkin"constantvoltagemode(CV)orconstantcurrentmode(CC)"todrivetheLEDs.
Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode [with LED driver, at area (A)] and CC mode [direct drive, at area (B)].
DRIVINGMETHODSOFLEDMODULE
TypicalLEDpowersupplyI-Vcurve
Vo(%)
100
50
50 100
(max.)
Io (%)
Constant
Voltage area
Constant
Current area
Hiccup
Protection
(A)
(B)
(C)
FileName:PLP-60-SPEC2010-09-06