www.clare.com
2
LAA108
R02
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics @ 25°C
Load Current
Continuous 1-I
L- - 300 mA
Peak t =10ms ILPK - - 400
On-Resistance 2IL=300mA RON - 4.5 8 Ω
Off-State Leakage Current VL=100VPILEAK --1μA
Switching Speeds
Turn-On IF=5mA, VL=10V tON - 0.43 3 ms
Turn-Off tOFF - 0.17 3
Output Capacitance 50V, f=1MHz COUT - 110 - pF
Input Characteristics @ 25°C
Input Control Current 3IL=300mA IF- 0.5 2 mA
Input Dropout Current - - 0.2 0.3 - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR--10μA
Common Characteristics @ 25°C
Input to Output Capacitance - CI/O -3-pF
1 If both poles operate simultaneously, the load current must be derated so as not to exceed the package total power dissipation value.
2 Measurement taken within one (1) second of on time.
3 For applications requiring high-temperature operation (T>60ºC), an LED drive currrent of 4mA is recommended.
Parameter Ratings Units
Blocking Voltage 100 VP
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
Input Power Dissipation 1150 mW
Total Power Dissipation 2800 mW
Isolation Voltage Input to Output 3750 Vrms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate Linearly 1.33 mw/˚C
2 Derate Linearly 6.67 mw/˚C
Electrical absolute maximum ratings are at 25°C
Absolute Maximum Ratings
Electrical Characteristics