New Product Switch Mode Power Supply S8FS-G (15/30/50/100/150/300/600-W Models) Superior Basic Performance That Ensures Reliability. Wide Range of Standards Certification and Greater Usability. * Superior basic performance that ensures reliability Ambient temperatures up to 70C, greater resistance to rusting with aluminum/stainless steel case, and applications at altitudes up to 3,000 m. * Certification for Global Standards North America: UL 508 (Listing)*, CSA C22.2 Europe: Overvoltage Category III (EN 50178) EMI: Class B (EN 61204-3) No need for control circuit transformers for which the Machinery Directive is specified. (EN/IEC 61558-2-16) * Refer to pages 4 to 10 for certified models. ! * Greater Usability The Terminal Block Cover prevents screws from dropping out and the Front Cover prevents ingress of foreign matter. Refer to Safety Precautions for All Power Supplies and Safety Precautions on page 29. Lineup Power rating Output voltage 5V 15 W 30 W 50 W 100 W 150 W 300 W 600 W Yes Yes Yes Yes Yes --- --- 12 V Yes Yes Yes Yes Yes Yes Yes 15 V Yes Yes Yes Yes Yes Yes Yes 24 V Yes Yes Yes Yes Yes Yes Yes 48 V --- --- --- --- Yes Yes Yes Model Number Structure Model Number Legend Note: Not all combinations are possible. Refer to List of Models in Ordering Information, below. S8FS- G@@@ @@ @ @-@ @ @ 1 1. Power Ratings 015: 15 W 030: 30 W 050: 50 W *1 100: 100 W *2 150: 150 W *3 300: 300 W 600: 600 W 2 3 4 5 2. Output voltage 05: 5 V 12: 12 V 15: 15 V 24: 24 V 48: 48 V 6 7 3. Configuration C: With cover/Direct mounting CD: With cover/DIN Rail mounting 5. Option (2) *5 None: None W: Parallel operation 4. Option (1) None: Screw terminal block E: Connectors *4 6. Option (3) *6 None: None R: Remote control *1. The output electric power is 40 W for products with an output voltage of 5 V. *2. The output electric power is 80 W for products with an output voltage of 5 V. *3. The output electric power is 105 W for products with an output voltage of 5 V. 7. Option (4) *7 None: None H: Extended hold time *4. Applicable only for 150 W or less and 24 V. *5. Applicable only for 600 W and 24 V. *6. Applicable only for 100 W or more and 24 V. *7. Applicable only for 300 W or more and 24 V. 1 S8FS-G Ordering Information List of Models Note: For details on normal stock models, contact your nearest OMRON representative. With Cover/Direct Mounting Power ratings Input voltage Output voltage (VDC) Output current 5V 3A S8FS-G01505C 15 W 30 W 50 W 100 to 240 VAC (Permissible range 85 to 264 VAC, 80 to 370 VDC) *4 100 W 150 W 300 W 600 W 100 to 240 VAC (Permissible range 85 to 264 VAC, 120 to 370 VDC) 100 to 240 VAC (Permissible range 85 to 264 VAC, 120 to 350 VDC) Built-in fan Model 12 V 1.3 A S8FS-G01512C 15 V 1A S8FS-G01515C 24 V 0.65 A S8FS-G01524C 5V 6A S8FS-G03005C 12 V 3A S8FS-G03012C 15 V 2.4 A S8FS-G03015C 24 V 1.5 A S8FS-G03024C 5V 8 A *1 S8FS-G05005C 12 V 4.3 A S8FS-G05012C 15 V 3.5 A None S8FS-G05015C 24 V 2.2 A S8FS-G05024C 5V 16 A *2 S8FS-G10005C 12 V 8.5 A S8FS-G10012C 15 V 7A S8FS-G10015C 24 V 4.5 A S8FS-G10024C 5V 21 A *3 S8FS-G15005C 12 V 13 A S8FS-G15012C 15 V 10 A S8FS-G15015C S8FS-G15024C 24 V 6.5 A 48 V 3.3 A S8FS-G15048C 12 V 25 A S8FS-G30012C 15 V 20 A S8FS-G30015C 24 V 14 A S8FS-G30024C 48 V 7A 12 V 50 A 15 V 40 A S8FS-G60015C 24 V 27 A S8FS-G60024C Yes S8FS-G30048C S8FS-G60012C 48 V 13 A S8FS-G60048C Note: 1. Ask your OMRON representative for pricing information on optional models. 2. Front-mounting is not possible. To mount a Power Supply from the front, purchase a DIN Rail-mounting Power Supply and a Front-mounting Bracket (sold separately). Refer to page 27. With Cover/Direct Mounting (Extended hold time type) Power ratings Input voltage 300 W 100 to 240 VAC (Permissible range 85 to 264 VAC, 120 to 370 VDC) 600 W 100 to 240 VAC (Permissible range 85 to 264 VAC, 120 to 350 VDC) Output voltage (VDC) Output current Built-in fan 14 A 24 V Model S8FS-G30024C-H Yes 27 A S8FS-G60024C-H With Cover/Direct Mounting (Connector type) Power ratings 15 W 30 W 50 W 100 W Input voltage 100 to 240 VAC (Permissible range 85 to 264 VAC, 80 to 370 VDC) *4 Output voltage (VDC) 150 W *1. The output electric power is 40 W. *2. The output electric power is 80 W. *3. The output electric power is 105 W. *4. Applicable to products produced from May 2018. 2 Output current Built-in fan 0.65 A 1.5 A 24 V 2.2 A Model S8FS-G01524CE S8FS-G03024CE None S8FS-G05024CE 4.5 A S8FS-G10024CE 6.5 A S8FS-G15024CE S8FS-G With Cover/DIN Rail Mounting Power ratings Input voltage 15 W 30 W 50 W 100 to 240 VAC (Permissible range 85 to 264 VAC, 80 to 370 VDC) *4 100 W 150 W 300 W 600 W 100 to 240 VAC (Permissible range 85 to 264 VAC, 120 to 370 VDC) 100 to 240 VAC (Permissible range 85 to 264 VAC, 120 to 350 VDC) Output voltage (VDC) Output current Built-in fan Model 5V 3A 12 V 1.3 A S8FS-G01512CD 15 V 1A S8FS-G01515CD 24 V 0.65 A S8FS-G01524CD S8FS-G01505CD 5V 6A S8FS-G03005CD 12 V 3A S8FS-G03012CD 15 V 2.4 A S8FS-G03015CD 24 V 1.5 A S8FS-G03024CD 5V 8 A *1 S8FS-G05005CD 12 V 4.3 A S8FS-G05012CD 15 V 3.5 A 24 V 2.2 A S8FS-G05024CD 5V 16 A *2 S8FS-G10005CD 12 V 8.5 A S8FS-G10012CD 15 V 7A S8FS-G10015CD None S8FS-G05015CD 24 V 4.5 A S8FS-G10024CD 5V 21 A *3 S8FS-G15005CD 12 V 13 A S8FS-G15012CD 15 V 10 A S8FS-G15015CD 24 V 6.5 A S8FS-G15024CD 48 V 3.3 A S8FS-G15048CD 12 V 25 A S8FS-G30012CD 15 V 20 A S8FS-G30015CD S8FS-G30024CD 24 V 14 A 48 V 7A 12 V 50 A Yes S8FS-G30048CD S8FS-G60012CD 15 V 40 A S8FS-G60015CD 24 V 27 A S8FS-G60024CD 13 A S8FS-G60048CD 48 V Note: Ask your OMRON representative for pricing information on optional models. *1. The output electric power is 40 W. *2. The output electric power is 80 W. *3. The output electric power is 105 W. *4. Applicable to products produced from May 2018. With Cover/DIN Rail Mounting (Extended hold time type) Power ratings Input voltage 300 W 100 to 240 VAC (Permissible range 85 to 264 VAC, 120 to 370 VDC) 600 W 100 to 240 VAC (Permissible range 85 to 264 VAC, 120 to 350 VDC) Output voltage (VDC) Output current Built-in fan 14 A 24 V Model S8FS-G30024CD-H Yes 27 A S8FS-G60024CD-H 3 S8FS-G Specifications Power rating Item Efficiency * Inrush current * (for a cold start at 25C) Output 24 V 84% typ. 85% typ. 200 VAC input 80% typ. 84% typ. 84% typ. 86% typ. 230 VAC input 80% typ. 84% typ. 84% typ. 86% typ. 1A 0.65 A 40 mVp-p max. 40 mVp-p max. 60 mVp-p max. Single phase, 85 to 264 VAC, 80 to 370 VDC 50/60 Hz (47 to 450 Hz) 100 VAC input 200 VAC input 0.32 A typ. 0.2 A typ. --- 100 VAC input 0.5 mA max. 200 VAC input 1 mA max. 100 VAC input 14 A typ. 200 VAC input 28 A typ. Rated Output Current 3A Voltage adjustment range * -10% to 15% (with V.ADJ) Ripple & Noise voltage * 40 mVp-p max. 100 to 240 VAC input Input variation influence * 0.5% max. Load variation influence * 1.0% max. 1.3 A Temperature variation influence 100 to 240 VAC input 0.05%/C max. Startup time * 100 VAC input 1,000 ms max. 200 VAC input 1,000 ms max. 100 VAC input 15 ms typ. 14 ms typ. 15 ms typ. 15 ms typ. 200 VAC input 75 ms typ. 70 ms typ. 75 ms typ. 70 ms typ. Hold time * Additional functions 15 V 84% typ. Power factor Leakage current * 12 V 80% typ. Frequency * Current * 5V 100 VAC input Voltage range * Input 15 W Output voltage Overload protection Yes, automatic reset Overvoltage protection * Yes, 120% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) Overheat protection No Series operation Yes (For up to two Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control No Output indicator Yes (LED: Green) 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA Insulation Environment Reliability Construction Withstand voltage 2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA 1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA Insulation resistance 100 M min. (between all output terminals and all input terminals/PE terminals) at 500 VDC Ambient operating temperature -20 to 70C (Derating is required according to the temperature.) (with no condensation or icing) Storage temperature -25 to 75C (with no condensation or icing) Ambient operating humidity 90% max. (Storage humidity: 90% max.) Vibration resistance 10 to 55 Hz, 4.5 G max., 0.375-mm half amplitude for 2 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in X, Y, Z directions MTBF 135,000 hrs min. Life expectancy * 10 years min. Dimensions (WxHxD) Refer to Dimensions on page 19. Weight 250 g Cooling fan No Degree of protection --- Harmonic current emissions EMI * Conforms to EN 61000-3-2 Conducted Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B Radiated Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B EMS Conforms to EN 61204-3 high severity levels Safety Standards UL 508 (Listing, excluding models with connector option) UL 60950-1, UL 62368-1 (Recognition, OVCII [ 3,000 m], Pol2) CSA C22.2 No.107.1 (excluding models with connector option) CSA C22.2 No.60950-1, No.62368-1 (excluding models with connector option) EN 50178 (OVCIII [ 2,000 m], OVCII [> 2,000 m and 3,000 m], Pol2) EN/IEC 60950-1, EN/IEC 62368-1 (OVCII [ 3,000 m], Pol2) Conforms to EN/IEC 61558-2-16 Conforms to PELV (EN/IEC 60204-1) Marine Standards No SEMI Conforms to F47-0706 (200 VAC input) Standards * Refer to Ratings, Characteristics, and Functions on page 11. 4 S8FS-G Power rating Item Efficiency * Output 86% typ. 200 VAC input 81% typ. 86% typ. 88% typ. 88% typ. 230 VAC input 81% typ. 86% typ. 88% typ. 89% typ. 2.4 A 1.5 A 60 mVp-p max. 50 mVp-p max. 60 mVp-p max. Single phase, 85 to 264 VAC, 80 to 370 VDC 50/60 Hz (47 to 450 Hz) 100 VAC input 200 VAC input 0.72 A typ. 0.43 A typ. --- 100 VAC input 0.5 mA max. 200 VAC input 1 mA max. Inrush current * (for a cold start at 25C) 100 VAC input 14 A typ. 200 VAC input 28 A typ. Rated Output Current 6A Voltage adjustment range * -10% to 15% (with V.ADJ) Ripple & Noise voltage * 50 mVp-p max. 100 to 240 VAC input Input variation influence * 0.5% max. Load variation influence * 1.0% max. Hold time * 24 V 86% typ. Leakage current * Temperature variation influence 15 V 84% typ. Power factor Startup time * Additional functions 12 V 81% typ. Frequency * Current * 5V 100 VAC input Voltage range * Input 30 W Output voltage 3A 100 to 240 VAC input 0.05%/C max. 100 VAC input 1,000 ms max. 200 VAC input 1,000 ms max. 100 VAC input 11 ms typ. 10 ms typ. 11 ms typ. 10 ms typ. 200 VAC input 60 ms typ. 50 ms typ. 50 ms typ. 55 ms typ. Overload protection Yes, automatic reset Overvoltage protection * Yes, 120% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) Overheat protection No Series operation Yes (For up to two Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control No Output indicator Yes (LED: Green) 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA Insulation Environment Reliability Construction Withstand voltage 2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA 1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA Insulation resistance 100 M min. (between all output terminals and all input terminals/PE terminals) at 500 VDC Ambient operating temperature -20 to 70C (Derating is required according to the temperature.) (with no condensation or icing) Storage temperature -25 to 75C (with no condensation or icing) Ambient operating humidity 90% max. (Storage humidity: 90% max.) Vibration resistance 10 to 55 Hz, 4.5 G max., 0.375-mm half amplitude for 2 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in X, Y, Z directions MTBF 135,000 hrs min. Life expectancy * 10 years min. Dimensions (WxHxD) Refer to Dimensions on page 19. Weight 250 g Cooling fan No Degree of protection --- Harmonic current emissions EMI * Conforms to EN 61000-3-2 Conducted Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B Radiated Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B EMS Conforms to EN 61204-3 high severity levels Safety Standards UL 508 (Listing, excluding models with connector option) UL 60950-1, UL 62368-1 (Recognition, OVCII [ 3,000 m], Pol2) CSA C22.2 No.107.1 (excluding models with connector option) CSA C22.2 No.60950-1, No.62368-1 (excluding models with connector option) EN 50178 (OVCIII [ 2,000 m], OVCII [> 2,000 m and 3,000 m], Pol2) EN/IEC 60950-1, EN/IEC 62368-1 (OVCII [ 3,000 m], Pol2) Conforms to EN/IEC 61558-2-16 Conforms to PELV (EN/IEC 60204-1) Marine Standards No SEMI Conforms to F47-0706 (200 VAC input) Standards * Refer to Ratings, Characteristics, and Functions on page 11. 5 S8FS-G Power rating Item Efficiency * Output 86% typ. 200 VAC input 82% typ. 86% typ. 88% typ. 89% typ. 230 VAC input 82% typ. 86% typ. 88% typ. 89% typ. 3.5 A 2.2A 40 mVp-p max. 40 mVp-p max. 60 mVp-p max. Single phase, 85 to 264 VAC, 80 to 370 VDC 50/60 Hz (47 to 450 Hz) 100 VAC input 200 VAC input 1.1 A typ. 0.62 A typ. --- 100 VAC input 0.5 mA max. 200 VAC input 1 mA max. Inrush current * (for a cold start at 25C) 100 VAC input 14 A typ. 200 VAC input 28 A typ. Rated Output Current 8A Voltage adjustment range * -10% to 15% (with V.ADJ) Ripple & Noise voltage * 40 mVp-p max. 100 to 240 VAC input Input variation influence * 0.5% max. Load variation influence * 1.0% max. Hold time * 24 V 86% typ. Leakage current * Temperature variation influence 15 V 84% typ. Power factor Startup time * Additional functions 12 V 81% typ. Frequency * Current * 5V 100 VAC input Voltage range * Input 50 W Output voltage 4.3 A 100 to 240 VAC input 0.05%/C max. 100 VAC input 1,000 ms max. 200 VAC input 1,000 ms max. 100 VAC input 14 ms typ. 11 ms typ. 10 ms typ. 10 ms typ. 200 VAC input 75 ms typ. 60 ms typ. 60 ms typ. 55 ms typ. Overload protection Yes, automatic reset Overvoltage protection * Yes, 120% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) Overheat protection No Series operation Yes (For up to two Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control No Output indicator Yes (LED: Green) 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA Insulation 2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA Withstand voltage 1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA 500 VAC for 1 min. (between all output terminals and RC terminals) current cutoff 20 mA Environment Reliability Construction Insulation resistance 100 M min. (between all output terminals and all input terminals/PE terminals) at 500 VDC Ambient operating temperature -20 to 70C (Derating is required according to the temperature.) (with no condensation or icing) Storage temperature -25 to 75C (with no condensation or icing) Ambient operating humidity 90% max. (Storage humidity: 90% max.) Vibration resistance 10 to 55 Hz, 4.5 G max., 0.375-mm half amplitude for 2 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in X, Y, Z directions MTBF 135,000 hrs min. Life expectancy * 10 years min. Dimensions (WxHxD) Refer to Dimensions on page 20. Weight 300 g Cooling fan No Degree of protection --- Harmonic current emissions EMI * Conforms to EN 61000-3-2 Conducted Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B Radiated Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B EMS Conforms to EN 61204-3 high severity levels Safety Standards UL 508 (Listing, excluding models with connector option) UL 60950-1, UL 62368-1 (Recognition, OVCII [ 3,000 m], Pol2) CSA C22.2 No.107.1 (excluding models with connector option) CSA C22.2 No.60950-1, No.62368-1 (excluding models with connector option) EN 50178 (OVCIII [ 2,000 m], OVCII [> 2,000 m and 3,000 m], Pol2) EN/IEC 60950-1, EN/IEC 62368-1 (OVCII [ 3,000 m], Pol2) Conforms to EN/IEC 61558-2-16 Conforms to PELV (EN/IEC 60204-1) Marine Standards No SEMI Conforms to F47-0706 (200 VAC input) Standards * Refer to Ratings, Characteristics, and Functions on page 11. 6 S8FS-G Power rating Output voltage Item Efficiency * Output Additional functions 15 V 24 V 79% typ. 84% typ. 85% typ. 87% typ. 200 VAC input 81% typ. 86% typ. 87% typ. 89% typ. 230 VAC input 81% typ. 86% typ. 87% typ. 89% typ. 7A 4.5 A 90 mVp-p max. 100 mVp-p max. 80 mVp-p max. Single phase, 85 to 264 VAC, 80 to 370 VDC Frequency * Input 12 V 100 VAC input Voltage range * Current * 100 W 5V 50/60 Hz (47 to 450 Hz) 100 VAC input 200 VAC input Power factor 2.1 A typ. 1.2 A typ. --- Leakage current * 100 VAC input 0.5 mA max. 200 VAC input 1 mA max. Inrush current * (for a cold start at 25C) 100 VAC input 14 A typ. 200 VAC input 28 A typ. Rated Output Current 16 A Voltage adjustment range * -10% to 15% (with V.ADJ) Ripple & Noise voltage * 70 mVp-p max. 100 to 240 VAC input Input variation influence * 0.5% max. Load variation influence * 1.0% max. 8.5 A Temperature variation influence 100 to 240 VAC input 0.05%/C max. Startup time * 100 VAC input 1,000 ms max. 200 VAC input 1,000 ms max. Hold time * 100 VAC input 12 ms typ. 11 ms typ. 11 ms typ. 10 ms typ. 200 VAC input 70 ms typ. 55 ms typ. 55 ms typ. 55 ms typ. Overload protection Yes, automatic reset Overvoltage protection * Yes, 120% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) Overheat protection No Series operation Yes (For up to two Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control Yes (Only for models with remote control option) Output indicator Yes (LED: Green) 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA 2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA Insulation Withstand voltage 1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA Only Remote control 500 VAC for 1 min. (between all output terminals and RC terminals) current cutoff 20 mA Environment Reliability Construction Insulation resistance 100 M min. (between all output terminals and all input terminals/PE terminals) at 500 VDC Ambient operating temperature -20 to 70C (Derating is required according to the temperature. Refer to Engineering Data) (with no condensation or icing) Storage temperature -25 to 75C (with no condensation or icing) Ambient operating humidity 90% max. (Storage humidity: 90% max.) Vibration resistance 10 to 55 Hz, 4.5 G max., 0.375-mm half amplitude for 2 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in X, Y, Z directions MTBF 135,000 hrs min. Life expectancy * 10 years min. Dimensions (WxHxD) Refer to Dimensions on page 21. Weight 400 g Cooling fan No Degree of protection --- Harmonic current emissions EMI * Conforms to EN 61000-3-2 Conducted Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B Radiated Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B EMS Conforms to EN 61204-3 high severity levels Safety Standards UL 508 (Listing, excluding models with connector option or remote control option) UL 508 (Recognition, models with remote control option) UL 60950-1, UL 62368-1 (Recognition, OVCII [ 3,000 m], Pol2) CSA C22.2 No.107.1 (excluding models with connector option or remote control option) CSA C22.2 No.60950-1, No.62368-1 (excluding models with connector option or remote control option) EN 50178 (OVCIII [ 2,000 m], OVCII [> 2,000 m and 3,000 m], Pol2) EN/IEC 60950-1, EN/IEC 62368-1 (OVCII [ 3,000 m], Pol2) Conforms to EN/IEC 61558-2-16 Conforms to PELV (EN/IEC 60204-1) Marine Standards No SEMI Conforms to F47-0706 (200 VAC input) Standards * Refer to Ratings, Characteristics, and Functions on page 11. 7 S8FS-G Power rating Output voltage Item Efficiency *1 Output Additional functions 24 V 48 V 78% typ. 84% typ. 85% typ. 87% typ. 85% typ. 200 VAC input 81% typ. 87% typ. 88% typ. 89% typ. 88% typ. 230 VAC input 81% typ. 87% typ. 88% typ. 90% typ. 88% typ. 10 A 6.5 A 3.3 A 110 mVp-p max. 80 mVp-p max. 110 mVp-p max. 120 mVp-p max. Single phase, 85 to 264 VAC, 80 to 370 VDC Frequency * Input 150 W 15 V 12 V 100 VAC input Voltage range * Current * 5V 50 /60 Hz (47 to 450 Hz) 100 VAC input 200 VAC input Power factor 3 A typ. 1.8 A typ. --- Leakage current * 100 VAC input 0.5 mA max. 200 VAC input 1 mA max. Inrush current * (for a cold start at 25C) 100 VAC input 14 A typ. 200 VAC input 28 A typ. Rated Output Current 21 A Voltage adjustment range * -10% to 15% (with V.ADJ) Ripple & Noise voltage * 100 mVp-p max. 100 to 240 VAC input Input variation influence * 0.5% max. Load variation influence * 1.0% max. 13 A Temperature variation influence 100 to 240 VAC input 0.05%/C max. Startup time * 100 VAC input 1,000 ms max. 200 VAC input 1,000 ms max. Hold time * 100 VAC input 14 ms typ. 10 ms typ. 10 ms typ. 10 ms typ. 11 ms typ. 200 VAC input 80 ms typ. 55 ms typ. 55 ms typ. 55 ms typ. 55 ms typ. Overload protection Yes, automatic reset Overvoltage protection * Yes, 120% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) Overheat protection No Series operation Yes (For up to two Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control Yes (Only for models with remote control option) Output indicator Yes (LED: Green) 3 kVAC for 1 min.(between all input terminals and output terminals) current cutoff 20 mA 2 kVAC for 1 min.(between all input terminals and PE terminals) current cutoff 20 mA Insulation Withstand voltage 1 kVAC for 1 min.(between all output terminals and PE terminals) current cutoff 20 mA Only Remote control 500 VAC for 1 min.(between all output terminals and RC terminals) current cutoff 20 mA Environment Reliability Construction Insulation resistance 100 M min.(between all output terminals and all input terminals/PE terminals) at 500 VDC Ambient operating temperature -20 to 70C (Derating is required according to the temperature. Refer to Engineering Data) (with no condensation or icing) Storage temperature -25 to 75C (with no condensation or icing) Ambient operating humidity 90% max. (Storage humidity: 90% max.) Vibration resistance 10 to 55 Hz, 4.5 G max., 0.375-mm half amplitude for 2 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in X, Y, Z directions MTBF 135,000 hrs min. Life expectancy * 10 years min. Dimensions (WxHxD) Refer to Dimensions on page 23. Weight 500 g Cooling fan No Degree of protection --- Harmonic current emissions EMI * Conforms to EN 61000-3-2 (Applicable at 80% or less of the rated load.) Conducted Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B Radiated Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B EMS Conforms to EN 61204-3 high severity levels Safety Standards UL 508 (Listing, excluding models with connector option or remote control option) UL 508 (Recognition, models with remote control option) UL 60950-1, UL 62368-1 (Recognition, OVCII [ 3,000 m], Pol2) CSA C22.2 No.107.1 (excluding models with connector option or remote control option) CSA C22.2 No.60950-1, No.62368-1 (excluding models with connector option or remote control option) EN 50178 (OVCIII [ 2,000 m], OVCII [> 2,000 m and 3,000 m], Pol2) EN/IEC 60950-1, EN/IEC 62368-1 (OVCII [ 3,000 m], Pol2) Conforms to EN/IEC 61558-2-16 Conforms to PELV (EN/IEC 60204-1) Marine Standards No SEMI Conforms to F47-0706 (200 VAC input) Standards Note: Refer to Ratings, Characteristics, and Functions on page 11. 8 S8FS-G Power rating Item Efficiency * 82% typ. 200 VAC input 85% typ. 85% typ. 87% typ. 87% typ. 230 VAC input 85% typ. 86% typ. 87% typ. 87% typ. 14 A 7A 270 mVp-p max. 150 mVp-p max. 330 mVp-p max. Single phase, 85 to 264 VAC, 120 to 370 VDC 50/60 Hz (47 to 63 Hz) 100 VAC input 200 VAC input 4.2 A typ. 2.1 A typ. 0.9 min. 100 VAC input 0.5 mA max. 200 VAC input 1 mA max. 14 A typ. Rated Output Current 25 A Voltage adjustment range * -10% to 15% (with V.ADJ) Ripple & Noise voltage * 100 to 240 VAC input 140 mVp-p max. Input variation influence * 0.5% max. Load variation influence * 1.0% max. Output Startup time * 28 A typ. 20 A 100 to 240 VAC input 0.05%/C max. 100 VAC input 1,000 ms max. 200 VAC input 1,000 ms max. 100 VAC input 30 ms typ. 30 ms typ. 30 ms typ. 40 ms typ. (Extended hold time type) 30 ms typ. 200 VAC input 30 ms typ. 25 ms typ. 30 ms typ. 40 ms typ. (Extended hold time type) 30 ms typ. Hold time * Overload protection Additional functions 48 V 82% typ. 100 VAC input Inrush current * (for a cold start at 25C) 200 VAC input Temperature variation influence 24 V 81% typ. Power factor Leakage current * 15 V 81% typ. Frequency * Current * 12 V 100 VAC input Voltage range * Input 300 W Output voltage Yes, automatic reset Overvoltage protection * Yes, 120% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) Overheat protection Yes, power shut off (shut off the input voltage and turn on the input again) Series operation Yes (For up to two Power Supplies, external diodes are required.) Parallel operation No (However, backup operation is possible, external diodes are required.) Remote sensing No Remote control Yes (Only for models with remote control option) Output indicator Yes (LED: Green) 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA 2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA Insulation Withstand voltage 1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA Only Remote control 500 VAC for 1 min. (between all output terminals and RC terminals) current cutoff 20 mA Environment Reliability Construction Insulation resistance 100 M min. (between all output terminals and all input terminals/PE terminals) at 500 VDC Ambient operating temperature -20 to 70C (Derating is required according to the temperature.) (with no condensation or icing) Storage temperature -25 to 75C (with no condensation or icing) Ambient operating humidity 90% max. (Storage humidity: 90% max.) Vibration resistance 10 to 55 Hz, 4.5 G max., 0.375-mm half amplitude for 2 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in X, Y, Z directions MTBF 135,000 hrs min. Life expectancy * 10 years min. Dimensions (WxHxD) Refer to Dimensions on page 25 Weight 700 g Cooling fan Yes Degree of protection --- Harmonic current emissions EMI * Conforms to EN 61000-3-2 Conducted Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B Radiated Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B EMS Conforms to EN 61204-3 high severity levels Safety Standards UL 508 (Listing, excluding models with remote control option) UL 508 (Recognition, models with remote control option) UL 60950-1, UL 62368-1 (Recognition, OVCII [ 3,000 m], Pol2) CSA C22.2 No.107.1 (excluding models with remote control option) CSA C22.2 No.60950-1, No.62368-1 (excluding models with remote control option) EN 50178 (OVCIII [ 2,000 m], OVCII [> 2,000 m and 3,000 m], Pol2) EN/IEC 60950-1, EN/IEC 62368-1 (OVCII [ 3,000 m], Pol2) Conforms to EN/IEC 61558-2-16 Conforms to PELV (EN/IEC 60204-1) Marine Standards No SEMI Conforms to F47-0706 (200 VAC input) Standards * Refer to Ratings, Characteristics, and Functions on page 11. 9 S8FS-G Power rating Output voltage Item Efficiency * 85% typ. 88% typ. 200 VAC input 88% typ. 88% typ. 89% typ. 92% typ. 230 VAC input 88% typ. 88% typ. 90% typ. 92% typ. 27 A 13 A 170 mVp-p max. 280 mVp-p max. 340 mVp-p max. Single phase, 85 to 264 VAC, 120 to 350 VDC 50 /60 Hz(47 to 63 Hz) 100 VAC input 200 VAC input 7.7 A typ. 3.8 A typ. 0.9 min. 100 VAC input 0.5 mA max. 200 VAC input 1 mA max. 100 VAC input Inrush current * (for a cold start at 25C) 200 VAC input 14 A typ. Rated Output Current 50 A Voltage adjustment range * -10% to 15% (with V.ADJ) Ripple & Noise voltage * 170 mVp-p max. 100 to 240 VAC input 28 A typ. Input variation influence * 0.5% max. Load variation influence * 1.0% max. 40 A Temperature variation influence 100 to 240 VAC input 0.05%/C max. Startup time * 100 VAC input 1,000 ms max. 200 VAC input 1,000 ms max. 100 VAC input 30 ms typ. 25 ms typ. 30 ms typ. 40 ms typ. (Extended hold time type) 30 ms typ. 200 VAC input 30 ms typ. 25 ms typ. 30 ms typ. 40 ms typ. (Extended hold time type) 30 ms typ. Output Hold time * Additional functions 48 V 84% typ. Power factor Leakage current * 24 V 84% typ. Frequency * Input 15 V 100 VAC input Voltage range * Current * 600 W 12 V Overload protection Yes, automatic reset Overvoltage protection * Yes, 120% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) Overheat protection Yes, power shut off (shut off the input voltage and turn on the input again) Series operation Yes (For up to two Power Supplies, external diodes are required.) Parallel operation Yes (up to five Power Supplies, S8FS-G60024 (models with parallel operation option) only). Remote sensing No Remote control Yes (Only Remote control) Output indicator Yes (LED: Green) 3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA 2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA Insulation Withstand voltage 1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA Only Remote control 500 VAC for 1 min. (between all output terminals and RC terminals) current cutoff 20 mA Environment Reliability Construction Insulation resistance 100 M min. (between all output terminals and all input terminals/PE terminals) at 500 VDC Ambient operating temperature -20 to 70C (Derating is required according to the temperature.) (with no condensation or icing) Storage temperature -25 to 75C (with no condensation or icing) Ambient operating humidity 90% max. (Storage humidity: 90% max.) Vibration resistance 10 to 55 Hz, 4.5 G max., 0.375-mm half amplitude for 2 h each in X, Y, and Z directions Shock resistance 150 m/s2, 3 times each in X, Y, Z directions MTBF 135,000 hrs min. Life expectancy * 10 years min. Dimensions (WxHxD) Refer to Dimensions on page 26. Weight 1,050 g Cooling fan Yes Degree of protection --- Harmonic current emissions EMI * Conforms to EN 61000-3-2 Conducted Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B Radiated Emissions Conforms to EN 61204-3 Class B, EN 55011 Class B EMS Conforms to EN 61204-3 high severity levels Safety Standards UL 508 (Listing, excluding models with remote control option) UL 508 (Recognition, models with remote control option) UL 60950-1, UL 62368-1 (Recognition, OVCII [ 3,000 m], Pol2) CSA C22.2 No.107.1 (excluding models with remote control option) CSA C22.2 No.60950-1, No.62368-1 (excluding models with remote control option) EN 50178 (OVCIII [ 2,000 m], OVCII [> 2,000 m and 3,000 m], Pol2) EN/IEC 60950-1, EN/IEC 62368-1 (OVCII [ 3,000 m], Pol2) Conforms to EN/IEC 61558-2-16 Conforms to PELV (EN/IEC 60204-1) Marine Standards No SEMI Conforms to F47-0706 (200 VAC input) Standards * Refer to Ratings, Characteristics, and Functions on page 11. 10 S8FS-G Ratings, Characteristics, and Functions Efficiency The value is when both rated output voltage and rated output current are satisfied. Voltage range Frequency Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. Current The value is when both rated output voltage and rated output current are satisfied. Leakage current The values are determined according to the Act on Power Supply Safety of Electrical Appliances and Materials. Inrush current (for a cold start at 25C) For a cold start at 25C. Refer to the following figure. Voltage adjustment range If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +15% of the voltage adjustment range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged. Ripple & Noise voltage The value is when both rated output voltage and rated output current are satisfied. A characteristic when the ambient operating temperature is 25C. Input variation influence This is the maximum variation in the output voltage when the input voltage is gradually changed within the allowable input voltage range at the rated output voltage and rated output current. Load variation influence This is the value when the output current is changed from 0 A to the rated output current while the input voltage is within the allowable input voltage. Startup time The value is when both rated output voltage and rated output current are satisfied. For a cold start at 25C. Refer to the following figure. Hold time The value is when both rated output voltage and rated output current are satisfied. At 25C. Refer to the following figure. Additional functions Overvoltage protection Refer to Overvoltage Protection on page 18 for the time when input voltage shuts off and input turns on again. Reliability Life expectancy Refer to Recommended Replacement Periods and Periodic Replacement for Preventive Maintenance on page 33 for details. Standards EMI Input Output Conducted Emissions Radiated Emissions The 150-W and higher models conform to Class B when an aluminum plate is set under the Power Supply. Standard Compliance * The input voltage range for compliance with EC Directives and other safety standards (UL, EN, etc.) is 90 to 264 VAC. * EN/IEC 61558-2-16 To comply with EN/IEC 60204-1 (Machine Safety), a transformer is required in the control circuit. If, however, a Power Supply that has a builtin transformer that complies with EN/IEC 6155-8-2-16 is used, an external transformer is not required. * Safety standard targets during a DC input * During a DC input, UL 62368-1, cUR (CSA C22.2 No. 62368-1), EN/IEC 62368-1, EN 50178, EN/IEC 61558-2-16, and EN/IEC 60204-1 are safety standard targets. (However, the input voltage range is 120 to 320 VDC. The safety standards during DC input are not acquired for the S8FS-G60048@.) It is possible to comply with the safety standards by connecting a UL-authenticated fuse. Select a UL-authenticated fuse that satisfies the following conditions: S8FS-G015@@/030@@ (320 VDC or above, 3 A) S8FS-G050@@ (320 VDC or above, 4 A) S8FS-G100@@ (320 VDC or above, 8 A) S8FS-G150@@ (320 VDC or above, 10 A) S8FS-G300@@ (320 VDC or above, 12 A) S8FS-G600@@ (320 VDC or above, 20 A) * To comply with the PELV output of the EN/IEC 60204-1, ground the output negative side (-V) to PE. * * Applicable to products produced from May 2018 11 S8FS-G Inrush Current, Startup Time, Output Hold Time Input ON Input OFF AC input voltage Inrush current on input application AC input current 96.5% 90% Output voltage Hold time Startup time Note: The total inrush current of all of the Power Supplies will flow for parallel operation or backup operation. Sufficiently check the fusing characteristics of fuses and the operating characteristics of breakers and select fuses and breakers so that external fuses will not burn out or breakers will not operate due to inrush current. Ripple Noise Voltage The specified standard for the ripple voltage noise was measured with a measurement circuit that is based on JEITA standard RC-9131A. +V C1 C2 S8FS-G Load -V 150mm C1:100F C2:0.47F Coaxial cable 12 Oscilloscope Frequency band: 100 MHz S8FS-G Connections Block Diagrams S8FS-G015@@@ (15 W) S8FS-G030@@@ (30 W) S8FS-G050@@@ (50 W) AC(L) INPUT +V Fuse 250 VAC 15/30 W: 3.15 A 50 W: 4 A HBC -V Inrush current protection AC(N) DC OUTPUT Noise filter Rectifier Smoothing circuit Rectifier smoothing circuit Control circuit Over current detection circuit Voltage detection circuit Over voltage detection circuit Photocoupler S8FS-G100@@@ (100 W) S8FS-G150@@@ (150 W) +V AC(L) INPUT AC(N) Fuse 250 VAC 100 W: 8 A 150 W: 10 A HBC +V DC OUTPUT Noise filter -V Inrush current protection Rectifier Smoothing circuit Rectifier smoothing circuit -V Control circuit Over current detection circuit Voltage detection circuit Photocoupler Over voltage detection circuit +RC REMOTE CONTROL -RC Only Remote control 13 S8FS-G S8FS-G300@@@ (300 W) +V AC(L) +V Fuse Noise filter 250 VAC 12 A HBC INPUT DC OUTPUT -V Rectifier AC(N) Inrush current protection Harmonic current suppression (power factor improvement) Smoothing circuit Rectifier smoothing circuit -V Drive circuit FAN Control circuit Over current detection circuit Rectifier smoothing circuit Voltage detection circuit Over voltage detection circuit Photocoupler Overheat detection circuit Overheat detection circuit +RC REMOTE CONTROL -RC Only Remote control S8FS-G600@@@ (600 W) +V AC(L) Fuse INPUT AC(L) 250 VAC 20 A HBC +V Noise filter DC OUTPUT Rectifier Inrush current protection Harmonic current Smoothing suppression circuit (power factor improvement) -V Rectifier smoothing circuit -V FAN Rectifier smoothing circuit Control circuit Over current detection circuit Over current detection circuit Overheat detection circuit Current detection circuit ONLY FOR PARALLEL OPERATION TYPE Voltage detection circuit Over voltage detection circuit Photocoupler Overheat detection circuit +RC REMOTE CONTROL -RC Only Remote control 14 Parallel operation selector S8FS-G Construction and Nomenclature Nomenclature S8FS-G015@@@ S8FS-G030@@@ S8FS-G050@@@ S8FS-G100@@@ S8FS-G150@@@ S8FS-G300@@@ S8FS-G600@@@ (1) (1) (2) (2) (3) (3) (9) (6) (6) (5) (4) (7) (6) (4) (7) (5) (8) (9) S8FS-G@@@24CE (3) (2) (1) (8) (9) S8FS-G@@@24C-R S8FS-G@@@24C-WR (2) (12) (11) (10) (9) (3) (4) (1) (1) (2) (3) (6) (4) (6) (5) (7) (6) (4) (7) (5) (8) (9) No. Terminal name (1) L (2) N (3) PE (4) +V1 (5) +V2 (6) -V1 (7) -V2 (8) (9) (10) +RC (11) -RC (8) (3) (2) (1) (8) (11) (10) (9) (8) (4) Name Function Connect the input lines to these terminals. *1 Input terminals Protective Earth terminal ( ) Connect the ground line to this terminal. *2 DC output terminals Connect the load lines to these terminals. --- Output indicator (DC ON: green) Lights while a direct current (DC) output is ON. --- Output voltage adjuster (V.ADJ) Use to adjust the voltage. Remote control terminals Wire for remote control. (12) --Parallel operation switch To operate in parallel, set the switch to the "PARALLEL" side. *1. The fuse is located on the (L) side. It is not user-replaceable. For a DC input, connect the positive voltage to the L terminal. *2. This is the protective earth terminal specified in the safety standards. Always ground this terminal. Input and Output Connectors (Connector type) Applicable connector Input side All models CN110 Output side S8FS-G01524@E S8FS-G03024@E S8FS-G05024@E CN510 S8FS-G10024@E S8FS-G15024@E Housing B3P5-VH (LF) (SN) VHR-5N B4P-VH (LF) (SN) VHR-4N B6P-VH (LF) (SN) VHR-6N Terminals Reel: SVH-21T-P1.1 Bulk: BVH-21T-P1.1 Applicable crimp tool YC-160R Manufacturer J.S.T. Mfg. Co., Ltd. Note: The female connectors that are required for wiring are not provided with the Power Supply. 15 S8FS-G Engineering Data Derating Curves Output Derating 300 W and 600 W 120 100 VAC or above 100 100 VDC or above 120 100 80 80 60 60 40 40 20 20 0 -30 -20 -10 0 10 20 30 40 50 60 70 80 Ambient Temperature (C) Note: 1. (For customers using the unit with an AC input) At a voltage below 100 VAC, reduce the load below the range of the derating curve shown above by the solid line, at the rate of 1.3%/V.s (40C < Ambient temperature 70C) 2. (For customers using the unit with a DC input) At a voltage below 100 VDC, reduce the load below the range of the derating curve shown above by the dashed line, by multiplying with the coefficient 0.9. Parallel Operation Load rate (%) For Models with Parallel Operation Option 120 100 85 80 60 40 20 0 -30 -20 -10 0 10 20 30 40 50 60 70 80 Ambient Temperature (C) Note: At a voltage below 100 VAC, reduce the load at the rate of 1.3%/V. 16 Load rate (%) Load rate (%) 15 W, 30 W, 50 W, 100 W, and 150 W 0 -30 -20 -10 0 10 20 30 40 50 60 70 80 Ambient Temperature (C) Note: At a voltage below 100 VAC, reduce the load at the rate of 1.3%/V. S8FS-G This Power Supply can be used at an altitude of 3,000 m. Between 2,000 and 3,000 m, derate the load according to the following derating curve. 15 W to 150 W (During a DC input) 120 100% 100 85% 45C max. 50C 60C 80 70C 120 100% 35C max. 100 90% 40C 80 70% 50C 55% 70% 60 Load rate (%) Load rate (%) 15 W to 150 W (During an AC input) 70C 60 40 50% 40 25% 20 60C 30% 20 0 0 0 500 0 1,000 1,500 2,000 2,500 3,000 3,500 500 1,000 1,500 2,000 2,500 3,000 3,500 Altitude (m) Altitude (m) Note: At a voltage below 100 VAC, reduce the load at the rate of 1.3%/V. (40C < Ambient temperature 70C) Note: At a voltage below 100 VDC, reduce the load by multiplying with the coefficient 0.9. Load rate (%) 300 W and 600 W 120 100% 45C max. 50C 100 60C 70% 80 70C 70 60 40% 40 10% 20 0 0 500 1,000 1,500 2,000 2,500 3,000 3,500 Altitude (m) Note: At a voltage below 100 VAC, reduce the load at the rate of 1.3%/V. 17 S8FS-G Engineering Data Remote Control Function (Only Remote control) The load and the Power Supply are automatically protected from overcurrent damage by this function. Overload protection is activated if the output current rises above 105 to 160% of the rated current. When the output current returns within the rated range overload protection is automatically cleared. This function is to turn ON/OFF the output by applying a voltage to the remote control connector from a DC power Supply (external power supply) other than this Power Supply. Built-in resistance Ri () Output voltage (V) Output voltage (V) Overload Protection 50 100 Output current (%) Output ON Output OFF Inrush current (mA) 4.5 to 12.5 0 to 0.5 20 max. 780 R Note 1 External power supply (SELV output) Intermittent operation 0 Voltage between +RC and -RC (V) 0 Inside the power supply Switch +RC 1 -RC 2 Ri Inflowing current 50 100 Output current (%) Remote control connector (CN61) Note: 1. Internal parts may occasionally deteriorate or be damaged if a short-circuited or overcurrent state continues during operation. 2. Internal parts may possibly deteriorate or be damaged if the Power Supply is used for applications with frequent inrush current or overloading at the load end. Do not use the Power Supply for such applications. Overvoltage Protection Consider the possibility of an overvoltage and design the system so that the load will not be subjected to an excessive voltage even if the feedback circuit in the Power Supply fails. If an excessive voltage that is 120% of the rated voltage or more is output, the output voltage is shut OFF. Reset the input power by turning it OFF for at least three minutes and then turning it back ON again. Overheating Protection (300 W and 600 W) If the internal temperature of the Power Supply rises excessively as a result of fan failure or any other reason, the overheat protection circuit will be triggered to shut OFF the output voltage. To restore operation, turn OFF the input power supply long enough for the Power Supply to cool sufficiently and then turn it ON again. Usage example of the remote control Connectors used: Model CN61 Applicable connector Applicable contact B2B-XH-AM XHP-2 SXH-001T-P0.6 or SXH-002T-P0.6 Manufacturer J.S.T. Mfg. Co., Ltd. Applicable crimp tool: YC-110R (J.S.T. Mfg. Co., Ltd.) or YRS-110 (J.S.T. Mfg. Co., Ltd.) Note: 1. When the external power supply is 4.5 to 12.5 V, the current limiting resistor R is not required. When it is 12.5 to 24.5 V, insert 1.5 k as the current limiting resistor R. 2. Reverse connection of the connector may cause damage on the internal parts. 3. The +RC and -RC terminals are the secondary circuit of the Power Supply. Use an SELV output power supply for an external power supply. The remote control circuit is insulated from the secondary output of the Power Supply (functional insulation). Reference Value Value Reliability (MTBF) 18 Single phase model 15W: 970,000 30W: 970,000 50W: 880,000 100W: 730,000 150W: 620,000 300W: 200,000 600W: 190,000 Definition MTBF stands for Mean Time Between Failures, which is calculated according to the probability of accidental device failures, and indicates reliability of devices. Therefore, it does not necessarily represent a life of the product. Life expectancy 10 yrs. Min. Definition The life expectancy indicates average operating hours under the ambient temperature of 40C and a load rate of 50%. Normally this is determined by the life expectancy of the built-in aluminum electrolytic capacitor. S8FS-G Dimensions (Unit: mm) Power Supplies 15 W and 30 W S8FS-G015@@C S8FS-G030@@C (14.3) 20.5 9.5 Panel mounting holes dimensions 550.5 8.2 Using the mounting holes in the Power Supply 3.5 Using the screw holes in the Power Supply 821 Side Mounting 400.5 40.5 Two, M3 (Depth 5 mm max.) 3.5 dia. Five, M3.5 88.50.5 5 Bottom Mounting 5 6.5 550.5 Two, M3 (Depth 3 mm max.) 18 Two, M3 Two, 3.5 dia. 740.5 870.5 3.5 870.5 17.5 S8FS-G015@@CD S8FS-G030@@CD Two, 3.5 dia. 88.50.5 991 3.5 dia. 400.5 Two, M3 28 351 740.5 (14.3) 117.71 5 9.5 8.2 32.5 49.5 3.5 (Sliding: 6.2 max.) Five, M3.5 36.21 5 max. S8FS-G015@@E S8FS-G030@@E 20.5 550.5 Panel mounting holes dimensions Input (L) Input (N) FG Output (-) Output (+) Using the mounting holes in the Power Supply 3.5 821 400.5 40.5 3.5 dia. Side Mounting 400.5 Two, M3 Using the screw holes in the Power Supply Two, 3.5 dia. 550.5 88.50.5 5 88.50.5 991 Bottom Mounting 5 Two, M3 (Depth 5 mm max.) 870.5 6.5 3.5 dia. Two, M3 Two, 3.5 dia. 870.5 740.5 3.5 351 Two, M3 (Depth 3 mm max.) 17.5 18 28 740.5 19 S8FS-G 50W S8FS-G050@@C (14.3) 20.5 9.5 550.5 Panel mounting holes dimensions 8.2 Using the mounting holes in the Power Supply 3.5 Using the screw holes in the Power Supply 971 55.50.5 Two, M3 (Depth 5 mm max.) Side Mounting 45.5 55.50.5 Two, M3 890.5 4.5 Bottom Mounting 5 Two, M3 6.5 870.5 18 740.5 3.5 361 29 18.5 Two, M3 (Depth 3 mm max.) Two, 3.5 dia. 870.5 991 3.5 dia. 550.5 890.5 3.5 dia. Five, M3.5 Two, 3.5 dia. 740.5 S8FS-G050@@CD (14.3) 9.5 5 117.71 8.2 49.5 47.5 5.5 (Sliding: 8.2 max.) Five, M3.5 37.21 5 max. S8FS-G050@@E 20.5 Panel mounting holes dimensions 550.5 Using the mounting holes in the Power Supply Input (L) Input (N) FG 3.5 971 Output (-) Output (+) 55.50.5 Side Mounting 55.50.5 Two, M3 Using the screw holes in the Power Supply Two, 3.5 dia. 550.5 45.5 3.5 dia. 890.5 4.5 Bottom Mounting 890.5 5 991 Two, M3 (Depth 5 mm max.) 870.5 6.5 3.5 dia. 3.5 361 Two, M3 (Depth 3 mm max.) 18.5 18 20 740.5 29 Two, M3 Two, 3.5 dia. 870.5 740.5 S8FS-G 100W S8FS-G100@@C (14.3) 9.5 Two, M3 (Depth 5 mm max.) 78 8.2 3.5 85.50.5 330.5 971 33 3.5 dia. Seven, M3.5 122.50.5 4.5 5.25 1291 1200.5 6.5 Three, M3 (Depth 6 mm max.) 3.5 3.5 dia. 28.5 130.5 180.5 381 28.5 19 32 770.5 10 Panel mounting holes dimensions Using the mounting holes in the Power Supply Using the screw holes in the Power Supply Two, 3.5 dia. Side Mounting 85.50.5 330.5 Two, M3 122.50.5 Bottom Mounting 130.5 Three, 3.5 dia. Three, M3 1200.5 90.5 770.5 180.5 S8FS-G100@@CD (14.3) 9.5 147.71 5 8.2 48.5 48.5 4.5 (Sliding: 7.2 max.) Seven, M3.5 39.21 5 max. 21 S8FS-G S8FS-G100@@E Two, M3 (Depth 5 mm max.) 78 3.5 Input (L) Input (N) FG 971 330.5 Output (-) 85.50.5 Output (+) 33 3.5 dia. 122.50.5 4.5 5.25 1291 1200.5 6.5 Three, M3 (Depth 6 mm max.) 3.5 3.5 dia. 28.5 130.5 180.5 381 28.5 19 32 770.5 10 Panel mounting holes dimensions Using the mounting holes in the Power Supply Using the screw holes in the Power Supply Two, 3.5 dia. Side Mounting 85.50.5 330.5 Two, M3 122.50.5 Bottom Mounting 130.5 1200.5 22 Three, 3.5 dia. Three, M3 90.5 770.5 180.5 S8FS-G 150W S8FS-G150@@C (14.3) 9.5 24 780.5 3.5 8.2 84.50.5 Two, M3 (Depth 5 mm max.) 971 32 3.5 dia. 152.50.5 4.5 Seven, M3.5 5.5 1591 Three, M3 (Depth 6 mm max.) 1500.5 6.5 3.5 3.5 dia. 130.5 180.5 28.5 381 28.5 19 22 1170.5 10.5 Panel mounting holes dimensions Using the mounting holes in the Power Supply Side Mounting Using the screw holes in the Power Supply Two, 3.5 dia. 84.50.5 780.5 Two, M3 152.50.5 Bottom Mounting 130.5 Three, M3 1500.5 Three, 3.5 dia. 9.50.5 1170.5 180.5 S8FS-G150@@CD (14.3) 8.2 177.71 5 9.5 47.9 49.1 Seven, M3.5 3.9 (Sliding: 6.6 max.) 39.21 5 max. 23 S8FS-G S8FS-G150@@E 24 780.5 Input (L) Input (N) FG 3.5 971 84.50.5 Output (-) Output (+) 32 3.5 dia. 152.50.5 4.5 5.5 1591 Two, M3 (Depth 5 mm max.) Three, M3 (Depth 6 mm max.) 1500.5 6.5 3.5 dia. 28.5 3.5 130.5 180.5 381 28.5 19 22 10.5 1170.5 Panel mounting holes dimensions Using the mounting holes in the Power Supply Side Mounting Using the screw holes in the Power Supply Two, 3.5 dia. 84.50.5 780.5 Two, M3 152.50.5 Bottom Mounting 130.5 Three, M3 1500.5 24 Three, 3.5 dia. 9.50.5 1170.5 180.5 S8FS-G 300W S8FS-G300@@C 9.5 Two, M4 (Depth 5 mm max.) 640.5 28.5 Panel mounting holes dimensions 8.2 Using the screw holes in the Power Supply 1021 Side Mounting Two, 4.5 dia. 640.5 Four, 4.5 dia. 50.5 Bottom Mounting 200.5 740.5 (14.1) Seven, M3.5 1701 60 (3.5) 740.5 200.5 411 12 Four, M4 (Depth 5 mm max.) S8FS-G300@@CD (14.1) 2011 9.5 5 8.2 53.5 48.5 Seven, M3.5 4.8 (Sliding: 7.5 max.) 42.51 Note: Use a metal DIN Rail when mounting a 300-W model to a DIN Rail. 5 max. 25 S8FS-G 600W S8FS-G600@@C Four, M4 (Depth 5 mm max.) Four, M4 9.7 20.5 11 1000.5 1201 9.5 8.2 10 Three, M3.5 24 1500.5 (3.7) (16.1) 1901 380.5 611 12.5 24 1500.5 (14.1) Four, M4 (Depth 5 mm max.) Panel mounting holes dimensions Using the screw holes in the Power Supply Four, 4.5 dia. Side Mounting 1000.5 1500.5 Bottom Mounting 380.5 Four, 4.5 dia. 1500.5 S8FS-G600@@CD (16.1) Four, M4 2211 10.8 5 9.7 62.5 20.5 8.2 9.5 57.5 (14.1) Three, M3.5 3.6 (Sliding: 6.3 max.) 62.51 Note: Use a metal DIN Rail when mounting a 600-W model to a DIN Rail. 26 5 max. S8FS-G Mounting Brackets (Order Separately) Use the Front-mounting Brackets together with DIN Rail-mounting Power Supplies (S8FS-G@@@@@CD). Power rating Mounting direction Model 15 W, 30 W, 50 W 100 W, 150 W and 300 W Front-mounting S82Y-FSG-30F 600 W Front-mounting S82Y-FSG-60F S82Y-FSG-30F Two, 4.50.1 dia 35 40 25 (ends) (R1.5) 1 27 7.3 (ends) 350.1 57 t=1.2 S82Y-FSG-60F Two, 4.50.1 dia 35 40 25 (ends) (R1.5) 350.1 1 48 7.3 (ends) 57 t=1.2 Note: Replacement brackets from the S8JX-N, S8JX-P, and S8VM series are available. Use these brackets for a front mounting configuration using direct mounting models. Refer to the data sheet (Cat. No.: T216-E1, T217-E1, and T218-E1) for more information. Terminal cover (Order Separately) Power rating Applicable models 15 W S8FS-G015@@@ 30 W S8FS-G030@@@ 50 W S8FS-G050@@@ 100 W S8FS-G100@@@ 150 W S8FS-G150@@@ 300 W S8FS-G300@@@ 600 W S8FS-G600@@@ Terminal Cover model number S82Y-FSG-C5P S82Y-FSG-C7P S82Y-FSG-C7P-L (Input Output) Note: A Terminal Block Cover is provided with the Power Supply as a standard accessory. You can purchase another one if your Cover is damaged or lost. 27 S8FS-G DIN Rail (Order Separately) (Unit: mm) Mounting Rail (Material: Aluminum) PFP-100N PFP-50N 7.30.15 4.5 350.3 15 25 10 25 25 10 1,000 (500) * 270.15 15(5) * 25 1 * Values in parentheses are for the PFP-50N. Mounting Rail (Material: Aluminum) PFP-100N2 16 4.5 350.3 27 15 25 10 25 25 10 1,000 25 15 24 29.2 1 1.5 End Plate PFP-M 10 6.2 M4x8 panhead screw 1.8 1 50 1.8 35.5 35.5 11.5 10 M4 spring washer 1.3 4.8 Note: If there is a possibility that the Unit will be subject to vibration or shock, use a steel DIN Rail. Otherwise, metallic filings may result from aluminum abrasion. 28 S8FS-G Safety Precautions Refer to Safety Precautions for All Power Supplies. Warning Indications CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage. Precautions for Safe Use Supplementary comments on what to do or avoid doing, to use the product safely. Precautions for Correct Use Supplementary comments on what to do or avoid doing, to prevent failure to operate, malfunction or undesirable effect on product performance. Meaning of Product Safety Symbols Used to warn of the risk of electric shock under specific conditions. Precautions for Safe Use Ambient Operating and Storage Environments * Store the Power Supply at a temperature of -25 to 75C and a humidity of 90% max. * The internal parts may occasionally deteriorate or be damaged. Use the Power Supply within the derating curve. * Use the Power Supply at a humidity of 90% max. * Do not use locations where liquids, foreign matter, or corrosive gases may enter the interior of the Power supplies. Installation Environment * Do not use the Power Supply in locations subject to shocks or vibrations. In particular, install the Power Supply as far away as possible from contractors or other devices that are a vibration source. * Install the Power Supply well away from any sources of strong, high-frequency noise and surge. Mounting Used to warn of the risk of minor injury caused by high temperatures. Use to indicate prohibition when there is a risk of minor injury from electrical shock or other source if the product is disassembled. Used for general mandatory action precautions for which there is no specified symbol. !CAUTION Minor electric shock, fire, or Product failure may occasionally occur. Do not disassemble, modify, or repair the Product or touch the interior of the Product. Minor burns may occasionally occur. Do not touch the Product while power is being supplied or immediately after power is turned OFF. * Take adequate measures to ensure proper heat dissipation to increase the long-term reliability of the Power Supply. Be sure to allow convection in the atmosphere around devices when mounting. Do not use in locations where the ambient temperature exceeds the range of the derating curve. The S8FS-G015@@@ to S8FS-G150@@@ are cooled by natural convection. Mount them so that air convection will occur around them. The S8FS-G300@@@ and S8FS-G600@@@ are cooled by forced airflow. Do not allow the ventilation holes to be blocked. The effectiveness of cooling would be reduced. * When cutting out holes for mounting, make sure that cuttings do not enter the interior of the Power supplies. * The internal parts may occasionally deteriorate and be broken due to adverse heat radiation. Do not loosen the screws on the Power Supply. * If you mount the Power Supply with the holes provided on the chassis, do not exceed the depth given in the dimensional diagrams. Use the following tightening torques. M3 screws: 0.48 to 0.59 N*m M4 screws: 1.08 to 1.32 N*m Fire may occasionally occur. Tighten terminal screws to the specified torque. M3.5: 0.74 to 1.13N*m M4: 1.08 to 1.32N*m Minor injury due to electric shock may occasionally occur. Do not touch the terminals while power is being supplied. Minor electric shock, fire, or Product failure may occasionally occur. Do not allow any pieces of metal or conductors or any clippings or cuttings resulting from installation work to enter the Product. 29 S8FS-G Mounting Wiring S8FS-G015@@@ to 150@@@ Bottom mounting 20 mm min. Side (horizontal orientation) mounting 20 mm min. 20 mm min. 20 mm min. S8FS-G300@@@ and S8FS-G600@@@ Bottom mounting 20 mm min. Side (horizontal orientation) mounting 20 mm min. 20 mm min. 20 mm min. * Connect the ground completely. A protective earthing terminal stipulated in safety standards is used. Electric shock or malfunction may occur if the ground is not connected completely. * Minor fire may possibly occur. Ensure that input and output terminals are wired correctly. * Do not apply more than 150-N force to the terminal block when tightening it. * Be sure to remove the sheet covering the Power Supply for machining before power-ON so that it does not interfere with heat dissipation. * Use the following material for the wires to be connected to the S8FS-G to prevent smoking or ignition caused by abnormal loads. Terminals and Wiring (Screw terminal block type) Terminals Model S8FS-G015@@@ Input 30 mm min. 30 mm min. AWG12-20 S8FS-G150@@@ to 600@@@ AWG12-16 S8FS-G03024@ 30 mm min. 30 mm min. AWG12-22 S8FS-G01505@ Ventilation holes S8FS-G03012@, 03015@ S8FS-G05015@, 05024@ AWG12-20 S8FS-G15048@ Note: Use a metal plate as the mounting surface. S8FS-G05012@ DIN rail mounting S8FS-G10024@ *1 AWG12-18 S8FS-G03005@ Output S8FS-G10015@ S8FS-G15024@ AWG12-16 S8FS-G30048@ *1. Convection of air. *2. 20 mm min. *2 AWG12-22 S8FS-G030@@@ to 100@@@ S8FS-G01512@ to 01524@ Ventilation holes Recommendes Wire Gauges S8FS-G05005@ S8FS-G10012@ *1 AWG12-14 S8FS-G15015@ *2 S8FS-G015@@@ to 150@@@ S8FS-G10005@ Side (vertical orientation) mounting S8FS-G30012@ to 30024@ S8FS-G15005@, 15012@ Side (upward) mounting *1 Bottom (upward) mounting *1 *1 *1 AWG12 S8FS-G60015@ to 60048@ AWG10-12 S8FS-G60012@ AWG10 Protective earth S8FS-G015@@@ to 600@@@ AWG12-14 terminal Note: The current capacity per output terminal is given in the following table. S8FS-G015@@@ to S8FS-G300@@@: 20 A S8FS-G600@@@: 30 A Use two terminals together if the current flow is higher than the rated terminal current. *1. 20 mm min. *2. Applicable to products produced from May 2018 Terminals and Wiring (Connector type) To mount the Power Supply to a DIN Rail, hook portion (A) of the Power Supply onto the DIN Rail and press the Power Supply in direction (B) until you hear it lock into place. Terminals (A) Input To dismount the Block, pull down portion (C) with a flat-blade screwdriver and pull out the Block. (C) 30 S8FS-G01524@E to 15024@E Recommendes Wire Gauges AWG18 Output S8FS-G01524@E to 15024@E AWG18 Note: 1. The current capacity per output terminal is 5 A. Use two or more terminals together if the current flow is higher than the rated terminal current. 2. Do not insert and remove any connector more than 20 times. 3. Refer to Input and Output Connectors on page 15 for the model numbers of the input and output connectors. (B) Rail stopper Model S8FS-G * Internal parts may possibly deteriorate or be damaged if a shortcircuited, overload, or boost load state continues during operation. * Internal parts may possibly deteriorate or be damaged if the Power Supply is used for applications with frequent inrush current or overloading at the load end. Do not use the Power Supply for such applications. Output Voltage Adjuster (V. ADJ) * The output voltage adjuster (V. ADJ) may possibly be damaged if it is turned with unnecessary force. Do not turn the adjuster with excessive force. * After completing output voltage adjustment, be sure that the output capacity or output current does not exceed the rated output capacity or rated output current. * Use the following information as a guide to the diode type, dialectic strength, and current. Type Schottky Barrier diode Dielectric strength (VRRM) Twice the output voltage or above Forward current (IF) Twice the rated output current or above Parallel Operation Parallel operation is used when the output current from one Power Supply is insufficient for the load. Power Supplies are connected in parallel to increase the output current. S8FS-G +V INPUT -V Load Overcurrent Protection S8FS-G Series Operation +V INPUT Two Power Supplies can be connected in series operation. -V +V INPUT Power Supplies without the Parallel Operation Option Load -V +V S8FS-G60024@-W@ (Models with the Parallel Operation Option) -V Note: 1. The diode is connected as shown in the figure. If the load is short-circuited, a reverse voltage will be generated inside the Power Supply. If this occurs the Power Supply may possibly deteriorate or be damaged. Always connect a diode as shown in the figure. Select a diode having the following ratings. Schottky Barrier diode Dielectric strength (VRRM) Twice the output voltage or above Forward current (IF) Twice the rated output current or above 2. Although Power Supply having different specifications can be connected in series, the current flowing through connected in series, the current flowing through the load must not exceed the smaller rated output current. * The outputs are floating outputs (i.e., the primary circuits and secondary circuits are separated). You can therefore make positive/negative outputs by using two Power Supplies. You can make positive/negative outputs with any of the models. If you use positive/negative outputs, connect two Power Supplies of the same model as shown below. You can combine models with different output capacities and output voltages. However, use the lower of the two rated rated output currents as the current to the loads. Up to five Power Supplies can be connected in parallel operation. You must meet the following conditions to use parallel operation. * The internal parts may occasionally deteriorate or be damaged. To operate in parallel, set the switch to the "PARALLEL" side. * For parallel operation, always use Power Supplies with the same model number. * Use the output voltage adjusters (V. ADJ) to adjust the difference in the output voltages to 50 mV or less between Power Supplies that are used in parallel operation. * The length and thickness of each wire connected to the load must be the same so that there is no difference in the voltage drop value between the load and the output terminals of each Power Supply. * Drastic fluctuations in the load (including fluctuations that occur when starting and starting the load) may reduce the output voltage. If fluctuations in the output voltage that result from drastic fluctuations in the load would be a problem, connect external diodes as shown in the following diagram. * Use the following information as a guide to the diode type, dialectic strength, and current. Type Schottky Barrier diode Dielectric strength (VRRM) Twice the output voltage or above Forward current (IF) Twice the rated output current or above +V +V Load INPUT -V +V INPUT -V Load INPUT Type Parallel operation is not possible. Load 0V +V INPUT +V -V -V INPUT -V * Depending on the model, internal circuits may be damaged due to startup failure when the power is turned ON if loads such as a servomotor or operational amplifier may operate in series. Therefore, connect bypass diodes (D1, D2) as shown in the following figure. If the list of models that support series connection of outputs says that an external diode is not required, an external diode is also not required for positive/negative outputs. D1 +V D2 INPUT Load Load -V Load +V INPUT -V 31 S8FS-G Backup Operation Charging a Battery Backup operation is possible if you use two Power Supplies of the same model. Even if one Power Supplies fails, operation can be continued with the other Power Supply. Make sure that the maximum load does not exceed the capacity of one Power Supply. Connect the S8VK-R or external diodes as shown in the following figure for backup operation. Refer to the S8VK-R datasheet (Cat. No.: T059) for information on using the S8VK-R. If you connect a battery as the load, install overcurrent control and overvoltage protection circuits. S8FS-G S8VK-R +V Load +V IN 1 INPUT -V -V S8FS-G +V INPUT IN 2 -V +V INPUT -V Load S8FS-G S8FS-G +V INPUT -V Use the following information as a guide to the diode type, dialectic strength, and current. Type Schottky Barrier diode Dielectric strength (VRRM) Twice the output voltage or above Forward current (IF) Twice the rated output current or above In Case There Is No Output Voltage There is a possibility that overload protection, overvoltage protection, or overheating protection are functioning. The internal protection may operate if a large amount of surge voltage, such as a lightning inrush, is applied to the input. In addition, other possible causes for some models include stoppage of the built-in fan and the remote control function (OFF). Check the following five points. If there is still no output voltage, contact your OMRON representative. * Checking Overload Protection: Remove the load wires and check whether the load is in an overload state or is short-circuited. * Checking Overvoltage or Internal Protection: Turn the power supply OFF, leave it OFF for at least three minutes, and then turn it ON again to see if this clears the condition. * Checking Overheating Protection (300 W/600 W): Turn OFF the input power supply long enough for the Power Supply to cool sufficiently and then turn it ON again. * Checking for Built-in Fan Stoppage (300 W/600 W): Check whether or not the built-in fan has stopped. * Confirming Remote Control Operation (Power Supplies with Remote Control): Check whether or not the +RC and -RC terminals are open. Connect the terminals as specified. 32 Built-in Fan Replacement The built-in fan cannot be replaced. Audible Noise at Power ON A harmonic current suppression circuit is built into the Power Supply. This circuit can create noise when the input is turned ON, but it will last only until the internal circuits stabilize and does not indicate any problem in the Power Supply. S8FS-G Period and Terms of Warranty Warranty Period The Power Supply warranty is valid for a period of three years from the date of shipment from the factory. Terms of Warranty The warranty is valid only for the following operating conditions. 1. Average ambient operating temperature of the Power Supply: 40C max. (See note.) 2. Average load rate of 80% max. (See note.) 3. Mounting method: Standard mounting 4. Rated input voltage Note: The maximum ratings must be within the derating curve. If the Power Supply fails for reasons attributable to OMRON within the above warranty period, OMRON will repair or replace the faulty part of the Power Supply at the place of purchase or the place where the Power Supply delivered without charge. This warranty does not cover the following types of failures. (1) Failures that result from handling or operation of the Power Supply under conditions or in environments that are not given in this document and not given in any other specifications exchanged between OMRON and the customer (2) Failures that originate in causes other than the delivered product itself (3) Failures caused by disassembly, modification, or repair of the Power Supply by anyone other than OMRON (4) Failures caused by applications or uses for which the Power Supply was not originally intended (5) Failures caused by factors that could not be anticipated with the scientific or technical knowledge available when the Power Supply was shipped (6) Failures caused by other causes for which OMRON is not responsible, such as natural disasters and other acts of God This warranty is limited to the individual Power Supply that was delivered and does not cover any secondary, subsequent, or related damages. Recommended Replacement Periods and Periodic Replacement for Preventive Maintenance The recommended replacement period for preventive maintenance is greatly influenced by the application environment of the Power Supply. As a guideline, the recommended replacement period is 7 to 10 years.* To prevent failures or accidents that can be caused by using a Power Supply beyond its service live, we recommend that you replace the Power Supply as early as possible within the recommended replacement period. However, bear in mind that the recommended replacement period is for reference only and does not guarantee the life of the Power Supply. Many electronic components are used in the Power Supply and the Power Supply depends on the correct operation of these components to achieve the original Power Supply functions and performance. However, the influence of the ambient temperature on aluminum electrolytic capacitors is large, and the service life is reduced by half for each 10C rise in temperature (Arrhenius law). When the capacity reduction life of the electrolytic capacitor is reached, the Power Supply failures or accidents may occur. We therefore recommend that you replace the Power Supply periodically to minimize product failures or accidents in advance. * The recommended replacement period applies under the following conditions: rated input voltage, load rate of 50% max., ambient temperature of 40C max., and the standard mounting method. This Power Supply model is designed with a service life of 10 years minimum under the above conditions. 33 MEMO 34 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company Authorized Distributor: Kyoto, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC 2895 Greenspoint Parkway, Suite 200 Hoffman Estates, IL 60169 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 (c) OMRON Corporation 2016-2018 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_2_9_0719 Cat. No. T207-E1-03 0418(1016)