FKID Power Entry Modules with Line Filter https://www.schurter.com /PG06 IEC Appliance Inlet C14 with Filter 2-Stage, Fuseholder 2-pole, Line Switch 2-pole C14 See below: Approvals and Compliances 70 C Description - Panel mount : Screw-on mounting from front side - 4 Functions : Appliance Inlet Protection class I , Fuseholder for fuse-links 5 x 20 mm 2-pole , Line Switch 2-pole , Line filter in standard and medical version , 2 positions - Quick connect terminals 6.3 x 0.8 mm Characteristics - Compact design with optimal shielding All single elements are already wired Plug removal necessary for fuse-link replacement 2-stage line filter with increased attenuation With EMC-shield - Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Other versions on request - Medical version M80 References Alternative: version without line filter 6765 Alternative: version with 1-stage filter FKI Weblinks pdf data sheet, html data sheet, General Product Information, Distributor-Stock-Check, Accessories, Detailed request for product Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Allowable Operation Temperature Climatic Category IP-Protection Protection Class Terminal Panel Thickness S Material: Housing 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 250 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21 acc. to IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 appliance inlet/-outlet Fuseholder Rated Power Acceptance @ Ta 23 C Power Acceptance @ Ta > 23C Line Switch Line Filter MTBF C14 acc. to IEC 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 C, 10 A, Protection Class I 2-pole, Shocksafe category PC2 acc. to IEC 60127-6, for fuse-links 5 x 20 mm 5 x 20: 1.6 W (2-pole) Admissible power acceptance at higher ambient temperature see derating curves 2-pole, non-illuminated, acc. to IEC 61058-1 Technical Details Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details > 1'200'000 h acc. to MIL-HB-217 F Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER. EMC Products 1 FKID Power Entry Modules with Line Filter https://www.schurter.com /PG06 Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: FKID Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40004665 UL Approvals UL UL File Number: E72928 Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference Designed according to IEC 60127-6 Miniature fuses. Part 6. Fuse-holders for miniature fuse-links Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements Designed according to UL 498 Standard for Attachment Plugs and Receptacles Designed according to UL 1283 Electromagnetic interference filters Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment. Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance Designed for applications acc. IEC 60335-1 Safety of electrical appliances for household and similar purposes. Meets the requirements for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC 60695-2-11 or -12 & -13. Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/836 China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. White paper Glow wire test SCHURTER AG Meets the requirements of IEC 60335-1 for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC 60695-2-11 or -12 &-13. Medical Equipment SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1 Product standards Product standards that are referenced Organization Application standards Application standards where the product can be used Organization Compliances The product complies with following Guide Lines Identification 2 EMC Products FKID Power Entry Modules with Line Filter https://www.schurter.com /PG06 Dimension [mm] Case 45 40 0.15 +0.5 61-0.2 R1 60.4 6.3x0.8 o 6.3x90 o 3.2 49 63 65 0.5 40 M3 3.5 28 R4 50 0.5 29.50.5 14 5.5 61.3 28.7 67 Technical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance Capacity Cy1 Capacity Cy2 CX [nF] [nF] [nF] R [M] 1 Standard Version 2 x 10 68 1.5 1 1 2 Standard Version 2x4 68 1.5 1 1 4 Standard Version 2 x 1.5 68 1.5 1 1 6 Standard Version 2 x 0.8 68 1.5 1 1 10 Standard Version 2 x 0.3 68 1.5 1 1 1 Medical Version (M5) 2 x 10 68 - - 1 2 Medical Version (M5) 2x4 68 - - 1 4 Medical Version (M5) 2 x 1.5 68 - - 1 6 Medical Version (M5) 2 x 0.8 68 - - 1 10 Medical Version (M5) 2 x 0.3 68 - - 1 Diagrams Standard version N Medical version (M5) F2 L1 1) PE Cx F1 L L1 Cy1 R 1) Line 2) Load L2 N' Cx Cy1 Cy2 L2 Cy2 PE' 2) L' N F2 1) PE L L1 R F1 Cx L2 L1 Cx N' PE' 2) L2 L' 1) Line 2) Load Derating Curves Admissible power acceptance in Watt 2-pole 1.6 1.4 1.2 I = 1.0 In 1.0 0.8 I = 0.7 In 0.6 I = << In 0.4 0.2 0.0 0 20 40 60 80 100 Ambient air temperature Ta C EMC Products 3 FKID Power Entry Modules with Line Filter https://www.schurter.com /PG06 Attenuation Loss - - - - 50 differential mode _____ 50 common mode Standard version 1A 2A 4A 6A 2A 4A 6A 10 A Medical version (M5) 1A 10 A All Variants Type Rated Current [A] FKID 1 FKID 2 FKID FKID Fuseholder Line Switch Housings Material: Housing Order Number Standard Version 2-pole 2-pole Standard Version 2-pole 2-pole 45 Aluminum 4304.5061 45 Aluminum 4304.5062 4 Standard Version 2-pole 6 Standard Version 2-pole 2-pole 45 Aluminum 4304.5063 2-pole 45 Aluminum FKID 10 Standard Version 4304.5064 2-pole 2-pole 45 Aluminum 4304.5065 FKID 1 Medical Version (M5) 2-pole 2-pole 45 Aluminum 4304.5081 FKID 2 Medical Version (M5) 2-pole 2-pole 45 Aluminum 4304.5082 FKID 4 Medical Version (M5) 2-pole 2-pole 45 Aluminum 4304.5083 FKID 6 Medical Version (M5) 2-pole 2-pole 45 Aluminum 4304.5084 FKID 10 Medical Version (M5) 2-pole 2-pole 45 Aluminum 4304.5085 FKID 1 Standard Version 2-pole 2-pole 45 Nickel plated steel 4304.5021 FKID 2 Standard Version 2-pole 2-pole 45 Nickel plated steel 4304.5022 FKID 4 Standard Version 2-pole 2-pole 45 Nickel plated steel 4304.5023 FKID 6 Standard Version 2-pole 2-pole 45 Nickel plated steel 4304.5024 4 Filter-Type EMC Products FKID Power Entry Modules with Line Filter https://www.schurter.com /PG06 Type Rated Current [A] FKID 10 FKID 2 Filter-Type Fuseholder Line Switch Housings Material: Housing Order Number Standard Version 2-pole 2-pole 45 Nickel plated steel 4304.5025 Medical Version (M5) 2-pole 2-pole 45 Nickel plated steel 4304.5067 Most Popular. Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER Packaging unit 10 Pcs Accessories Description Assorted Covers Rear Cover 0859.0074 Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete 4787, Mounting: Screw-on mounting, Appliance Outlet: IEC Solder terminals, 10 A, Suitable for appliances with protection class I 4787 4788, Mounting: Snap-in version, Appliance Outlet: IEC Solder terminals or quick connect terminals, 10 A, Suitable for appliances with protection class I 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 Appliance Outlet further types to FKID Connector Overview complete 4782 4785 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C13 4785 4300-06 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06 4781 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C15 4781 4784 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C15 4784 Connector further types to FKID ... 27.03.2019 4782 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C13 The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. EMC Products 5