KA 2032
A5E39968267A/RS-AE, 11/2018 3
Use for the intended purpose
The ATEX gearbox fulfills the requirements of the Explosion Protection Directive 2014/34/EU.
In the case of ATEX version gearboxes, please observe the instructions marked with this symbol.
The SIMOGEAR worm geared motors described in these operating instructions have been designed for stationary use in
general engineering applications.
They comply with the harmonized standards of the series EN 60034 (VDE 0530). The use of LA/LE motors in hazardous
zones and areas is forbidden.
Unless otherwise agreed, the gearboxes have been designed for use in plants and equipment in industrial environments.
The gearboxes and geared motors are designed and built according to state-of-the-art technology and are shipped in an
operationally safe condition. Changes made by users could affect this operational reliability and are forbidden.
Note
The data on the rating plate assumes an installation altitude of up to 1
000 m above sea level.
e ambient temperature is stamped on the rating plate.
For different installation altitudes and ambient temperatures, contact Technical Support.
The gearboxes and geared motors have been designed solely for the application described in the technical data. Do not
operate
the gearbox or the geared motor outside the specified power limit. Other operating conditions must be contractually
agreed.
Do not climb on the gearbox. Do not place any objects on the gearbox or the geared motor.
The operator must ensure that all persons assigned to work on the geared motor have read and understood these operating
instructions and that they follow them in all points in order to:
● Eliminate the risk to life and limb of users and other persons.
● Ensure the operational safety of the geared motor.
● Avoid disruptions and environmental damage through incorrect use.
Note the following safety information:
Shut down the geared motors and disconnect the power before you carry out any work on them.
Make sure that the drive unit cannot be turned on accidentally, e.g. lock the key-operated switch. Place a warning notice at
the drive connection point which clearly indicates that work is in progress on the geared motor.
Carry out all work with great care and with due regard to "safety".
For all work, observe the relevant regulations for work safety and environment protection.
Read the instructions on the rating plates attached to the geared motor. The rating plates must be kept free from paint and
dirt at all times. Replace any missing rating plates.
In the event of changes during operation, switch off the drive unit immediately.
Take appropriate protective measures to prevent accidental contact with rotating drive parts, such as couplings, gear wheels
or belt drives.
Take appropriate protective measures to prevent accidental contact with parts and equipment that heat up to over +70 °C
during operation.
When removing protective equipment, keep fasteners in a safe place. Re-attach removed protective equipment before
commissioning.
Collect and dispose of used oil in accordance with regulations. Remove oil spillages immediately with an oil-binding agent in
compliance with environmental requirements.