Evaluates: MAX6639/MAX6639F
checkbox results in the PWM output being high at
100% duty cycle. Unchecking the Positive PWM
Polarity checkbox results in the PWM output being low
at 100% duty cycle.
The Min. speed drop-down list selects the value of the
minimum fan speed (when the temperature is below the
fan-start temperature in the automatic RPM mode).
There are two possible selections: 0% duty cycle or
Set by Start TACH. Selecting 0% duty cycle results in
the fan being off when the temperature is below the
fan-start temperature value. Selecting Set by Start
TACH (0x22) or Set by Start TACH (0x23) results in
the fan operating at the minimum speed set for fan 1 or
fan 2.
Read the configuration 2A register by pressing the
Read button. Change the configuration by selecting the
desired options and pressing the Write button.
Fan 1 and Fan 2 Configuration 2B
The fan 1 Configuration 2B (0x12) and fan 2
Configuration 2B (0x16) group boxes also apply to the
automatic RPM mode (Figure 4). The Configuration 2B
(0x16) group box is not shown, but can be accessed
by navigating to the Fan 2 tab sheet from Figure 4.
These group boxes set the tachometer step sizes and
number of steps for step-size A to step-size B slope
changes.
The RPM step-size B drop-down list selects the number
of tachometer counts that the target value decreases for
each temperature-step increase above the fan-start
temperature. The value can be set between 1 and 16.
The Number of steps drop-down list sets the number
of temperature/tachometer steps above the fan-start
temperature at which step-size B begins. The number
of steps can be set between 1 and 16. Read the config-
uration 2B register by pressing the Read button.
Change the configuration by selecting the desired
options and pressing the Write button.
Fan 1 and Fan 2 Configuration 3
The fan 1 Configuration 3 (0x13) and fan 2
Configuration 3 (0x17) group boxes control fan spin-
up, THERM to fan full speed, pulse stretching, and
PWM output frequency (Figure 4). The Configuration 3
(0x17) group box is not shown, but can be accessed
by navigating to the Fan 2 tab sheet from Figure 4.
The fan spin-up feature ensures that the fan starts.
Whenever the fan starts up from zero drive, it is driven
with 100% duty cycle for 2s to ensure that it starts. Fan
spin-up is enabled by default. To disable this feature,
check the Fan Spin Up Disable checkbox.
When the THERM to Fan Full Speed checkbox is
checked, THERM going low—either by being pulled low
MAX6639 Evaluation Kit
8 _______________________________________________________________________________________
Table 3. Mask Register Checkboxes