CSM_D4CC_DS_E_3_1
1
Miniature Limit Switch
D4CC
Many Models Including Roller Lever
Switches are Only 16-mm Thick with
Connector
New center roller lever models that enable ganged mounting of up to
6 Switches.
Cable connectors for easy Switch replacement.
Triple-seal construction to provide IEC IP67 degree of protection.
Operation indicators available for easy monitoring (standard indicator
is lit when Switch is not operating).
Approved by UL and CSA.
(Ask your OMRON representative for Information on approved
models.)
Be sure to read Safety Precautions on page 7 to 8
and Safety Precautions for All Limit Switches.
Model Number Structure
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
Ordering Information
Switches
Limit Switches
Note: 1. Ask your OMRON representative for Information on approved models.
2. The meaning of suffix codes in the D4CC model numbers is different from that in the D4C model numbers.
3. Refer to the following table for cable plugs.
Ratings 1 A at 125 VAC 1 A at 30 VDC
Actuator
LED indicator Without indicator With indicator Without indicator With indicator
Model Model Model Model
Pin
plunger D4CC-1001 D4CC-2001 D4CC-3001 D4CC-4001
Roller
plunger D4CC-1002 D4CC-2002 D4CC-3002 D4CC-4002
Crossroller
plunger D4CC-1003 D4CC-2003 D4CC-3003 D4CC-4003
High-sensitivity
roller lever D4CC-1024 D4CC-2024 D4CC-3024 D4CC-4024
Sealed pin
plunger D4CC-1031 D4CC-2031 D4CC-3031 D4CC-4031
Sealed roller
plunger D4CC-1032 D4CC-2032 D4CC-3032 D4CC-4032
Sealed crossroller
plunger D4CC-1033 --- D4CC-3033 D4CC-4033
Plastic
rod D4CC-1050 D4CC-2050 D4CC-3050 D4CC-4050
Center
roller lever D4CC-1060 D4CC-2060 D4CC-3060 D4CC-4060
D4CC-@0@@
(1) (2)
(1) Rated Current
1 : 1 A at 125 VAC
2 : 1 A at 125 VAC (with LED indicator)
3 : 1 A at 30 VDC
4 : 1 A at 30 VDC (with LED indicator)
(2) Actuator
01 : Pin plunger
02 : Roller plunger
03 : Crossroller plunger
24 : Roller lever
31 : Sealed pin plunger
32 : Sealed roller plunger
33 : Sealed crossroller plunger
50 : Plastic rod
60 : Center roller lever
2
D4CC
Applicable Cables
Special Mounting Plate (Order Separately)
It is possible to replace an WL Limit Switch with a D4CC Limit Switch mounted on this plate without changing the position of the dog or cam.
List of Replaceable Models Example of Replacement
Note: The position of the dog remains unchanged.
Specifications
Approved Standards
Ratings
Note: 1. The above current ratings are for steady-state current.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time
constant of 7 ms max. (DC).
3. Lamp loads have an inrush current of 10 times the steady-state current.
4. Motor loads have an inrush current of 6 times the steady-state current.
D4CC-3, D4CC-4, 1 A at 30 VDC
Approved Standard Ratings
UL/CSA
D4CC-1, D4CC-2
D150
Characteristics
Note: The above figures are initial values.
*1. The values are calculated at an operating temperature of +5°C to +35°C,
and an operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating
environments.
*2. Excluding plastic rod models.
Leakage Current for Switches with Indicators
The leakage current and resistance of Switches with indicators are as follows:
Type For AC For DC
Appearance
No. of
conductors Cable length Model Model
Straight
4
1 m XS2F-A421-C90-A XS2F-D421-C80-A
2 m XS2F-A421-D90-A XS2F-D421-D80-A
5 m XS2F-A421-G90-A XS2F-D421-G80-A
10 m XS2F-A421-J90-A XS2F-D421-J80-A
WL model
(Actuator)
D4CC model
(Actuator) Plate
WLD
(Top plunger)
D4CC-@001
(Plunger) D4C-P001
WLD2
(Top roller plunger)
D4CC-@002
(Roller plunger) D4C-P002
WLG2
(Roller lever)
D4CC-@024
(Roller lever) D4C-P020
Dog Dog
Mounting
plate
Agency Standard File No.
UL UL508 E76675
CSA CSA C22.2 No. 14 LR45746
Rated
voltage
Non-inductive load (A) Inductive load (A)
Resistive
load Lamp load Inductive
load Motor load
NC NO NC NO NC NO NC NO
125 VAC 1110.71111
30 VDC 11111111
Inrush
current
NC 5 A max.
NO 2.5 A max.
Rated
voltage
Carry
current
Current (A) Volt-amperes (VA)
Make Break Make Break
120 VAC 1.0 A 3.6 0.6 432 72
Degree of protection IP67
Durability *1Mechanical 10,000,000 operations min.
Electrical
200,000 operations min. (1 A at 125 VAC, resistive load)
Operating speed 0.1 mm/s to 0.5 m/s (in case of plunger)
1 mm/s to 1 m/s (in case of roller lever)
Operating
frequency
Mechanical 120 operations/min
Electrical 30 operations/min
Rated frequency 50/60 Hz
Insulation resistance 100 M min. (at 500 VDC)
Contact resistance (initial) 100 m max.
Dielectric
strength
Between terminals
of same polarity
1,000 VAC, 50/60 Hz for 1 min
Between current-
carrying metal
parts and ground
1,500 VAC, 50/60 Hz for 1 min
Between each termi-
nal and non-current-
carrying metal part
1,500 VAC, 50/60 Hz for 1 min
Vibration
resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude *2
Shock
resistance
Destruction 1,000 m/s2 min.
Malfunction 500 m/s2 min. *2
Ambient operating temperature
10°C to +70°C (with no icing)
Ambient operating humidity 35% to 95%RH
Weight Approx. 120 g (in the case of D4CC-1002)
Item Model D4CC-2@@@ D4CC-4@@@
Voltage 125 VAC 30 VDC
Leakage current 1.0 mA 1.0 mA
Resistive value 150 k30 k
3
D4CC
Structure and Nomenclature
Structure
Center Roller Lever Models with Indicator
Contact Form
AC Switches (D4CC-10@@, 20@@)
Without Operation Indicator
With Operation Indicator (Lit when Not Actuated) *1
DC Switches (D4CC-30@@, 40@@)
Without Operation Indicator
With Operation Indicator (Lit when Not Actuated) *1
*1. "Lit when not actuated" means that when the actuator is in the free position, the indicator is lit, and when the actuator is turned or pushed and the contact comes
into contact with the NO side, the indicator turns OFF.
*2. The position of the positioning piece is not always the same. If using an L-shaped connector causes problems in application, use a straight connector.
Connections
Roller
Center lever
O-ring (NBR)
Built-in switch
Ground terminal
Molded resin
Protective nitrile
rubber cap (NBR)
Nitrile rubber
diaphragm
O-ring
(NBR)
Connector
receptacle
Open space (to reduce
a change in internal
pneumatic pressure and to
prevent the respiratory
movement of the Switch.)
LED indicator
Spacer
prevents the Switch from biting cut chips.
Pin No.1 COM NC Pin No.2
NO Pin No.4 E
E
Pin No.1 COM NC Pin No.2
NO Pin No.4
150 k
Positioning
piece *2
Pin No.1 COM NC Pin No.2
NO Pin No.4 E
E
Pin No.1 COM NC Pin No.2
NO Pin No.4
30 k
Positioning
piece *2
Pin No.
Plug Cable
Brown (Red)
White (Orange)
Blue (Black)
Black (White)
Pin No.
Plug Cable
Brown (Red)
White (Orange)
Blue (Black)
Black (White)
For A
C
For D
C
Note: Colors in parentheses are the previous wire colors. Wire colors have been changed accompanying changes in standards.
4
D4CC
Dimensions and Operating Characteristics (Unit: mm)
Switches
Limit Switches The @ in each model number is replaced with the code expressing the rated load of the model. Refer to Model Number Legend.
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
* The TT is a reference value.
Operating Characteristics
Mod-
el D4CC-@001 D4CC-@002 D4CC-@003 D4CC-@024 D4CC-@031
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
max.
11.77 N
4.41 N
1.8 mm
3 mm
0.2 mm
11.77 N
4.41 N
1.8 mm
3 mm
0.2 mm
11.77 N
4.41 N
1.8 mm
3 mm
0.2 mm
5.69 N
1.47 N
10°±3°
50°
3°
17.65 N
4.41 N
1.8 mm
3 mm
0.2 mm
Operating Position
Total travel
OP
TT *
15.7±1 mm
---
28.5±1 mm
---
28.5±1 mm
--- --- 24.9±1 mm
(5) mm
75 max.
Indicator
M12 × 1
10.5
59.5 max.
(2)
OP
PT 40 max.
16
2.8
12 dia. × 4.4 stainless steel roller
Correct
setting
position
2
1.4 1.5
7.5
7
8
23
2
34
25±
0.1
holes
Spot facing
10.2 dia. depth: 6
Two, 5.1
+0.2
0
dia.
62.2 max.
Indicator
M12 × 1
10.5
57 max.
(2)
OP
PT 40 max.
16
2.8
10 dia.
stainless steel plunger
Correct
setting
position
25±
0.1
2
1.4 1.5
Two, 5.1
+0.2
0
dia.
holes
Spot facing
10.2 dia. depth: 6
7.5
4.5
8
23
2
34
75 max.
Indicator
M12 × 1
10.5
59.5 max.
(2)
OP
PT 40 max.
16
2.8
12 dia. × 4.4
stainless steel roller
Correct
setting
position
2
1.4 1.5
7.5
7
8
23
2
34
25±
0.1
holes
Spot facing
10.2 dia. depth: 6
Two, 5.1
+0.2
0
dia.
110.7
max.
40 max.
50 max.
16
65 max.
17.5 dia. × 7 stainless
sintered roller
38R
7
2
11.4
M5 Allen-head
bolt
(length: 12)
7.5
8
23
Indicator
M12 × 1
10.5
(2)
1.4 1.5
2
34
25±
0.1
44±
0.8
30.2±
0.8
31.5±
0.8
holes
Spot facing 10.2 dia.
depth: 6
Two, 5.1
+0.2
0
dia.
Crossroller Plunger
D4CC-@003
Pin Plunger
D4CC-@001
Roller Plunger
D4CC-@002
Roller Lever
D4CC-@024
57 max.
OP
PT
40 max.
16
10 dia.
stainless steel plunger
Rubber seal
2
7.5
4
8
23
Indicator
M12 × 1
10.5 (2)
1.4 1.5
2
34
25±
0.1
holes
Spot facing
10.2 dia. depth: 6
Two, 5.1
+0.2
0
dia.
Sealed Pin Plunger
D4CC-@031
5
D4CC
The @ in each model number is replaced with the code expressing the rated load of the model. Refer to Model Number Legend.
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
* The TT is a reference value.
Applicable Cables Select one of the specified Connector Plugs from the following table.
Operating Characteristics
Model D4CC-@032 D4CC-@033 D4CC-@050 D4CC-@060
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
max.
min.
max.
min.
max.
17.65 N
4.41 N
1.8 mm
3 mm
0.2 mm
17.65 N
4.41 N
1.8 mm
3 mm
0.2 mm
1.47 N
---
15°
---
---
6.67 N
1.47 N
10°±3°
50°
3°
Operating Position
Total travel
OP
TT *
34.3±1 mm
(5) mm
34.3±1 mm
(5) mm --- ---
OP
PT
40 max.
16
12 dia. × 4.4
stainless steel roller
Rubber seal
2
8
23
7.5
4
57 max.
(2)
Indicator
M12 × 1
10.5
1.4 1.5
2
34
holes
Spot facing
10.2 dia. depth: 6
25±
0.1
Two, 5.1
+0.2
0
dia.
Sealed Roller Plunger
D4CC-@032
38 3.2 dia.
6.6 dia.
*2
42
16
Nylon rod
2
Rubber seal
7.5
4.5
8
23
2
34
1.4 1.5
57 max.
Indicator
*1. Operation is possible in any direction except parallel to the axis .
*2.
The ideal range for operation is between the tip of the rod and 1/3 of the length of the actuator.
M12 × 1
10.5 (2)
40 max.
*1
25±
0.1
104±
2.5
holes
Spot facing
10.2 dia. depth: 6
Two, 5.1
+0.2
0
dia.
Plastic Rod
D4CC-@@50
OP
PT
40 max.
16
12 dia. × 4.4
stainless steel roller
2
1.4 1.5
8
23
Rubber seal
7.5
4
57 max.
Indicator
M12 × 1
10.5
34
(2)
2
25±
0.1
holes
Spot facing
10.2 dia. depth: 6
Two, 5.1
+0.2
0
dia.
Sealed Crossroller Plunger
D4CC-@033
65.65
38R
110.7 max. 18.9
40 max.
17.5 dia. × 7
stainless steel roller
7.5
7
8
23
1.4 1.5
2
34
Indicator
M12 × 1
11
(2)
16
25±
0.1
holes
Spot facing
10.2 dia. depth: 6
Two, 5.1
+0.2
0
dia.
Center Roller Lever
D4CC-@@60
6 dia.
40.7
14.9 dia.
L50
30 5
45°
5 dia.
M12
45°
5 dia.
M12
XS2F-D421-@80-A (For DC)
XS2F-A421-@90-A (For AC)
(For DC) (For AC)
For AC Model For DC Model Cable length (L)
(m)
XS2F-A421-C90-A XS2F-D421-C80-A 1
XS2F-A421-D90-A XS2F-D421-D80-A 2
XS2F-A421-G90-A XS2F-D421-G80-A 5
XS2F-A421-J90-A XS2F-D421-J80-A 10
6
D4CC
Special Mounting Plates (Limit Switches are not attached to the Plates.)
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Remarks
There is no difference in mounting pitch between the Mounting Plate
and the WL. The mounting depth of the D4CC with the Mounting Plate
attached is, however, shorter than that of the panel-mounted WL.
34
(OP of WLD)
18.3
58.7±
0.2
15.7 7
13.1
5.1±
0.2
Two, M5 × 0.8
tapped hole *2
95
11 dia.
1.3
44
4-2R 30.2±
0.2
30
34.1
*1. All the holes with 5.2 dia. must be used
with M5
× 10 Allen-head bolts.
*2. All the M5-tapped holes must be used with M5
hexagonal flat head bolts.
25±
0.2
Four, 5.2
+0.2
0
dia. holes *1
+0.2
0
D4
C
-P001
(
For D4
CC
-
@
001
)
Note: Four hexagonal flat head bolts
(M5 × 0.8, length: 10) and two
Allen-head bolts (M5 × 0.8,
length: 15) are included.
44
15.5
28.5
9.5
13.1
95
1.3
34.1
44
4-2R
30
11 dia.
(OP of WLD2)
25±0.2
58.7±0.2
30.2±0.2
5.1±0.2
Two, M5 × 0.8
tapped hole *2
*1. All the holes with 5.2 dia. must be used
with M5
× 10 Allen-head bolts.
*2. All the M5-tapped holes must be used with M
5
hexagonal flat head bolts.
+0.2
0
Four, 5.2+0.2
0 dia. holes *1
D4
C
-P002
(
For D4
CC
-
@
002
)
Note: Four hexagonal flat head bolts
(M5 × 0.8, length: 10) and two
Allen-head bolts (M5 × 0.8,
length: 15) are included.
75
14.7
Two, 4
+0.12
0
dia.
(for positioning),
into which a spring
pin is press-fitted.
1.3
58.7±
0.2
11 dia.
44
4-2R
34.1
30
25±
0.1
53±
1.5
9±
0.2
9.2±
0.2
5±
0.2
Two, M5 × 0.8
tapped hole *2
30.2±
0.2
*1. All the holes with 5.2 dia. must be used
with M5
× 10 Allen-head bolts.
*2. All the M5-tapped holes must be used with M
5
hexagonal flat head bolts.
+0.2
0
Four, 5.2
+0.2
0
dia. holes *1
D4
C
-P020
(
For D4
CC
-
@
024
)
Note: Four hexagonal flat head bolts
(M5 × 0.8, length: 10), two
Allen-head bolts (M5 × 0.8,
length: 15), and two spring
pins (4 × 14) are included.
7
D4CC
Safety Precautions
Refer to Safety Precautions for All Limit Switches.
Operating Environment
Seal material may deteriorate if a Switch is used outdoor or where subject to special
cutting oils, solvents, or chemicals. Always appraise performance under actual
application conditions and set suitable maintenance and replacement periods.
Install Switches where they will not be directly subject to cutting
chips, dust, or dirt. The Actuator and Switch must also be protected
from the accumulation of cutting chips or sludge.
Constantly subjecting a Switch to vibration or shock can result in
wear, which can lead to contact interference with contacts,
operation failure, reduced durability, and other problems.
Excessive vibration or shock can lead to false contact operation or
damage. Install Switches in locations not subject to shock and
vibration and in orientations that will not produce resonance.
The Switches have physical contacts. Using them in environments
containing silicon gas will result in the formation of silicon oxide
(SiO2) due to arc energy. If silicon oxide accumulates on the
contacts, contact interference can occur. If silicon oil, silicon filling
agents, silicon cables, or other silicon products are present near the
Switch, suppress arcing with contact protective circuits (surge
killers) or remove the source of silicon gas.
Mounting
Make sure that the plate to which the
D4CC is mounted is flat. If the plate is
warped or has protruding parts, the
D4CC may not malfunction.
A maximum of 6 Switches may be
group-mounted. In this case, pay attention to the mounting direction so that
the convex part of the group-mounting guide on one Switch fits into the
concave part of the guide on the other Switch as shown in the figure below.
For group mounting, the mounting panel must have a thickness (t) of 6 mm
min.
Be sure to tighten each screw to the proper tightening torque as shown in the table.
* By removing the two screws from the head, the head
direction can be rotated 180°. After changing the head
direction, re-tighten to the torque specified above. Be
careful not to allow any foreign substance to enter the
Switch.
Operation
Operation method, shapes of cam and dog, operating frequency,
and overtravel have a significant effect on the service life and
precision of a Limit Switch. For this reason, the dog angle must be
30° max., the surface roughness of the dog must be 6.3S min. and
hardness must be Hv400 to 500.
To allow the plunger-type actuator to travel properly, adjust the dog
and cam to the proper setting positions. The proper position is
where the plunger groove fits the bushing top.
To allow the roller lever-type actuator to
travel properly, adjust the dog and cam so
that the arrow head is positioned between
the two convex markers as shown below.
Properly adjust the stroke of the center
roller lever along with the dog or cam so
that the concave part (A) of the head is
located between the convex parts of the
head as shown below when the center
roller lever is pressed by the dog or cam.
Refer to the following to adjust the stroke of
the lever based on the mounting hole level.
Precautions for Correct Use
No. Type Appropriate tightening torque *
(1) M5 Allen-head bolt 4.90 to 5.88 N·m
(2)
M3.5 head mounting screw
0.78 to 0.88 N·m
(3) M5 Allen-head bolt 4.90 to 5.88 N·m
Not Suitable Suitable
Two, 5.2-dia. or
M5 screw holes
25±0.1
Mounting Holes
Mounting plate
16 mm
t
Group-mounting
guide
(Front: convex
Rear: concave)
Group Mounting
(3)
(2)
(1)
Bushing top
Dog
Groove 2.8 m
m
Arrow head
Convex
marker
Proper
range
A
Proper
range
A
Convex parts of head
Proper
range
Prope
r
range
Proper range Proper range
44.9
(Total Travel Position)
65.3 to 64.6
(Operating Position)
8
D4CC
Plug Tightening
Connect the plug connector (B) to the connector threads (C) of the
D4CC. Then firmly turn the plug connector by hand so that the
connector threaded portion (C) will be completely covered by the
plug connector (B) so that space (A) will be almost 0.
Do not use any tools, such as pliers, to tighten the plug connector,
otherwise the plug connector may become damaged. Make sure,
however, that the plug connector is tightened securely, otherwise
the rated degree of protection of the D4CC may not be maintained.
Furthermore, the plug connector may be loosened by vibration.
Others
If failures, such as reset failures, in the plunger model are possible,
use a model that has a rubber cap.
Do not expose the Switch to water exceeding 70°C or use it in
steam.
D4CC
(A)
(C) (B)
(A)
(B)
D4CC
P
roper
l
y
Ti
g
h
tene
d
C
onnector
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2008.11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Right Reserved.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
D4CC3002 D4CC-1024 D4CC-3002