Model P155
Stainless Steel Pressure Transducer
14501 Los Angeles Avenue, Moorpark, California 93021 USA
(805) 523-2000 ¥ FAX (805) 523-7125
www.kavlico.com ¥ e-mail: sales@kavlico.com
Operating Temp: See seal material in ÒHow To OrderÓ
Linearity: ±0.5% of Span MAX.
Hysteresis and
Repeatability: ±0.05% of Span MAX.
Response Time: 10 mSec at 63% full scale
Wetted Materials: Stainless steel housing, 96% alumina
ceramic sensing element. See seal
material in ÒHow to OrderÓ
Vibration: 10GÕs peak to peak sinusoidal
Shock: 75GÕs, 1/2 sine wave
Operating Life: 10 million cycles minimum at full
operating pressure
Weight: 3.5 oz. MAX.
Elec. Termination: Integral weatherproof connector,
Packard Electric Metri-Pack 150 Series
Recommended 25K Ohm MIN. resistance between
Interface Impedance: transducer output and ground
Pressure Ranges: 0-15 through 0-1000 PSIA/PSIG
Proof Pressure (PSI): 5x(15-75), 3x(100-300), 2x(500-1000)
Burst Pressure (PSI): 10x(15-75), 5x(100-300), 4x(500-1000)
Supply Voltage: 5.000
Output Voltage
(Ratiometric): 0.500 (±0.060) Vdc at 0 PSI
4.500 (±0.060) Vdc at Full Scale
Supply Current: 5mA MAX. at 5 Vdc
Output Impedance: 100 Ohms MAX.
Temp. Error (0¡C to +85¡C):
Zero ±0.02% of Span per ¡C MAX.
Span ±0.02% of Span per ¡C MAX.
Temp. Error (-30¡C to +100¡C):
Zero ±0.04% of Span per ¡C MAX.
Span ±0.04% of Span per ¡C MAX.
SPECIFICATIONS
Warranty: Kavlico warrants that its products will be free from defective materials
and workmanship for a period of one (1) year from date of delivery to the original
purchaser and that its products will conform to KavlicoÕs specifications or standards. Any
product found to be defective will be replaced or repaired at the sole option of Kavlico.
Note: Kavlico reserves the right to change its specifications at any time without notice.
Kavlico is not expert in the customerÕs technical field and therefore does not warrant
the suitability of its product for the application selected by the customer.
Kavlico products are manufactured or covered by one or more of the following patents:
4329732, 4388668, 4398426, 4425799, 4426673, 4617607, 4680971, 4735098,
4974117, 5315877, 5329819, 5540086 with other U.S. and foreign patents pending.
The case of this device is not connected to the ground lead.
Three lead wires Red (Supply Voltage), Black (Ground), Green
(Output) provide electrical connection to power and instrumenta-
tion. Teflon tape or suitable sealant may be used on NPT pressure
fittings in suitable amounts so as not to interfere with a good ground
connection to chassis.
OUTLINE DRAWING
DS-P155-8/98
*VITON is a trademark of E.I. DuPont
INSTALLATION
HOW TO ORDER
Pressure Range
15 0-15 PSI
30 0-30 PSI
50 0-50 PSI
75 0-75 PSI
100 0-100 PSI
150 0-150 PSI
300 0-300 PSI
500 0-500 PSI
750 0-750 PSI
1000 0-1000 PSI
Reference
A Absolute
G Gage
Seal Material
B Buna-N (Nitrile) -40 to +120¡C
C Neoprene -34 to +120¡C
D Fluorocarbon (Viton)* -17 to +125¡C
E Fluorosilicone -40 to +125¡C
F Ethylene-Propylene -40 to +125¡C
Pressure Connection
1 1/4-18 NPT Male
2 3/8-24 UNF-2A Male
3 3/8-24 UNF-2B Female
4 1/8 NPT Male
Electrical Connector
A With mating connector,
12Ó leads 16 AWG
P155 - 15 A - E 1 A
Technology That FitsTM
A typical order number has six codes, separated by two hyphens
P155 Pressure Transducer
Example: P155-15A-E1A
VENT HOLE
ON GAGE
REFERENCE
UNITS
Note: Performance Specifications with 5 ±0.002 Vdc power supply at 25¡C
Span is the algebraic difference between end points (zero and full scale output).
Contact Kavlico for alternative pressure ranges, pressure connections or voltage ranges.
Units are in
inches
[mm]