14501 Los Angeles Avenue, Moorpark, California 93021 USA
(805) 523-2000 ¥ FAX (805) 523-7125
www.kavlico.com ¥ e-mail: sales@kavlico.com
Model P155
Stainless Steel
Pressure Transducer
• Linear Amplified Output
• Temperature Compensated
Over Wide Range
• Over-voltage, Reverse Polarity
& Short Circuit Protection
• Many OEM Options
• 10 Year Minimum Shelf Life
• Sensor Lifetime in Millions
of Cycles
• Outstanding Shock &
Vibration Tolerance
• Made in U.S.A.
Solutions for tomorrows sensing applications...TodayTM
The Model P155 pressure transducer
is specifically designed for pressure
measurements 0-15 through 0-1000
PSI. The stainless steel housing
and ceramic diaphragm withstand
exposure to compatible liquid and
gaseous media.
Excited by 5 Vdc, the P155 provides
a 0.5 through 4.5 Vdc linear signal
output proportional to pressure.
Typical applications include steam
sterilizers, laboratory test apparatus,
marine, agricultural chemical equipment,
refrigeration and HVAC systems,
hydraulic systems, gas tank pressure
monitoring, level measurement, test
equipment, pressure measurement of
aggressive fluids, injection molding,
atmospheric pressure, spraying
equipment, printing pressures,
coolant pressures, weighing
equipment and off-shore drilling rigs.
Key to the high performance of
the P155 pressure transducer
is KavlicoÕs ceramic, variable
capacitance sensing element with
ASIC and hybrid circuit for reliable
signal conditioning and maximum
electronic integration. This same
technology is successfully used by
Kavlico for automotive, diesel engine,
medical and HVAC applications.
Millions of Kavlico sensors are in
use worldwide.
KavlicoÕs sophisticated manufacturing practices have
earned the highest quality awards from its customers.
As an ISO 9001 registered company, Kavlico is
committed to total customer satisfaction. Each and every
pressure sensor is tested for conformance to its
applicable specifications prior to shipment.
OPERATION
APPLICATIONS
The design of application specific sensors to meet
demanding OEM requirements is KavlicoÕs primary
function. Using the broadest range of sensing
technologies, we provide components with greater
EMI and over-voltage protection. Solid state switching
functions and voltage regulators can be built into Kavlico
sensors for use with unregulated power.
OEM DESIGNS
• Dry & Wet Media
• Superior Long Term Stability
• Excellent Repeatability/Hysteresis
• EMI/RFI Protection
• Low Power Consumption
QUALITY
FEATURES
Model P155
Stainless Steel Pressure Transducer
14501 Los Angeles Avenue, Moorpark, California 93021 USA
(805) 523-2000 ¥ FAX (805) 523-7125
www.kavlico.com ¥ e-mail: sales@kavlico.com
Operating Temp: See seal material in ÒHow To OrderÓ
Linearity: ±0.5% of Span MAX.
Hysteresis and
Repeatability: ±0.05% of Span MAX.
Response Time: 10 mSec at 63% full scale
Wetted Materials: Stainless steel housing, 96% alumina
ceramic sensing element. See seal
material in ÒHow to OrderÓ
Vibration: 10GÕs peak to peak sinusoidal
Shock: 75GÕs, 1/2 sine wave
Operating Life: 10 million cycles minimum at full
operating pressure
Weight: 3.5 oz. MAX.
Elec. Termination: Integral weatherproof connector,
Packard Electric Metri-Pack 150 Series
Recommended 25K Ohm MIN. resistance between
Interface Impedance: transducer output and ground
Pressure Ranges: 0-15 through 0-1000 PSIA/PSIG
Proof Pressure (PSI): 5x(15-75), 3x(100-300), 2x(500-1000)
Burst Pressure (PSI): 10x(15-75), 5x(100-300), 4x(500-1000)
Supply Voltage: 5.000
Output Voltage
(Ratiometric): 0.500 (±0.060) Vdc at 0 PSI
4.500 (±0.060) Vdc at Full Scale
Supply Current: 5mA MAX. at 5 Vdc
Output Impedance: 100 Ohms MAX.
Temp. Error (0¡C to +85¡C):
Zero ±0.02% of Span per ¡C MAX.
Span ±0.02% of Span per ¡C MAX.
Temp. Error (-30¡C to +100¡C):
Zero ±0.04% of Span per ¡C MAX.
Span ±0.04% of Span per ¡C MAX.
SPECIFICATIONS
Warranty: Kavlico warrants that its products will be free from defective materials
and workmanship for a period of one (1) year from date of delivery to the original
purchaser and that its products will conform to KavlicoÕs specifications or standards. Any
product found to be defective will be replaced or repaired at the sole option of Kavlico.
Note: Kavlico reserves the right to change its specifications at any time without notice.
Kavlico is not expert in the customerÕs technical field and therefore does not warrant
the suitability of its product for the application selected by the customer.
Kavlico products are manufactured or covered by one or more of the following patents:
4329732, 4388668, 4398426, 4425799, 4426673, 4617607, 4680971, 4735098,
4974117, 5315877, 5329819, 5540086 with other U.S. and foreign patents pending.
The case of this device is not connected to the ground lead.
Three lead wires Red (Supply Voltage), Black (Ground), Green
(Output) provide electrical connection to power and instrumenta-
tion. Teflon tape or suitable sealant may be used on NPT pressure
fittings in suitable amounts so as not to interfere with a good ground
connection to chassis.
OUTLINE DRAWING
DS-P155-8/98
*VITON is a trademark of E.I. DuPont
INSTALLATION
HOW TO ORDER
Pressure Range
15 0-15 PSI
30 0-30 PSI
50 0-50 PSI
75 0-75 PSI
100 0-100 PSI
150 0-150 PSI
300 0-300 PSI
500 0-500 PSI
750 0-750 PSI
1000 0-1000 PSI
Reference
A Absolute
G Gage
Seal Material
B Buna-N (Nitrile) -40 to +120¡C
C Neoprene -34 to +120¡C
D Fluorocarbon (Viton)* -17 to +125¡C
E Fluorosilicone -40 to +125¡C
F Ethylene-Propylene -40 to +125¡C
Pressure Connection
1 1/4-18 NPT Male
2 3/8-24 UNF-2A Male
3 3/8-24 UNF-2B Female
4 1/8 NPT Male
Electrical Connector
A With mating connector,
12Ó leads 16 AWG
P155 - 15 A - E 1 A
Technology That FitsTM
A typical order number has six codes, separated by two hyphens
P155 Pressure Transducer
Example: P155-15A-E1A
VENT HOLE
ON GAGE
REFERENCE
UNITS
Note: Performance Specifications with 5 ±0.002 Vdc power supply at 25¡C
Span is the algebraic difference between end points (zero and full scale output).
Contact Kavlico for alternative pressure ranges, pressure connections or voltage ranges.
Units are in
inches
[mm]