Fast-Acting Aircraft Limiter
ACH Series
1108 BU-SB08803 Form No. ACH Page 1 of 2 Data Sheet 1041
Catalog Symbol: ACH
Fast-Acting
Ratings:
Amps: 1 to 60A
Volts: 208Vac
125Vdc
Interrupting Ratings: 6000A @ 120Vac
4200A @ 208Vac
6000A @ 125Vac
At sea level to 6000 ft.
Test specification - carry 200% rated current for 5 minutes, open at
240% within 5 minutes.
Dimensions - in (mm)
Symbol Amps A B C D
ACH 2, 3, 5, 10, 15, 1.97 0.06 0.48 1.33
20, 25 or 30 (50.0mm) (1.59mm) (12.3mm) (33.8mm)
ACH 35, 40, 50 or 60 2.22 0.09 0.55 1.45
(56.39mm) (2.27mm) (13.97mm)(36.83mm)
Cooper Bussmann Aircraft Fuses
Mechanical Indicating - Limiter type
• ACH limiters are designed to meet the very rigorous requirements of high
speed, high performance aircraft.
• Isolate faults or grounds in aircraft electric systems of 120/208 volts 400
cycles AC or 125 volts DC.
• ACH limiters give visual indication when open by a spring-activated pin that
extends from the limiter body.
• Blade terminals on ACH limiters are silver-plated.
• Limiters are made with a silicone body that assures reliable performance
under severe conditions.