2 FORM C--200 mW SENSITIVE MINIATURE RELAY 1500 V FCC SURGE WITHSTAND UL File No.: E43149 CSA File No.: LR26550 9.9 .390 20 .787 DS2YRELAYS 9.3 .366 * 2 Form C contact * High sensitivity: 200 mW nominal operating power * High breakdown voltage 1500 V FCC surge between open contacts * DIP: 2C type matching 16 pin IC socket * Sealed construction mm inch SPECIFICATIONS Contact Arrangement 50 m Contact material Rating (resistive) Initial insulation resistance*1 2 Form C Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Gold-clad sliver Max. switching power 60 W, 62.5 VA Max. switching voltage 220 V DC, 250V AC Between open contacts Initial breakdown Between contact sets voltage*2 Between contact and coil 1,000 Vrms FCC surge voltage between contacts and coil 1,500 V 3 2A Operate time* (at nominal voltage) Approx. 4 ms Max. carrying current 3A Release time (without diode)*3 (at nominal voltage) Approx. 3 ms 0.3 A 125 V AC 0.3 A 110 V DC 1 A 30 V DC 1 x 108 Mechanical Expected life (min. 1 A 30 V DC operations) Electrical 2 A 30 V DC 3 Set time* (latching) (at nominal voltage) Shock resistance Minimum operating power Approx. 98 mW (147 mW: 48 V) Nominal operating power Approx. 200 mW (300 mW: 48 V) Minimum set and reset power Approx. 88 mW (177 mW: 48 V) Nominal set and reset power Approx. 180 mW (360 mW: 48 V) Conditions for operation, transport and storage*7 Functional*4 Min. 490 m/s2 {50 G} 5 Destructive* Min. 980 m/s2 {100 G} Functional*6 196 m/s2 {20 G}, 10 to 55 Hz at double amplitude of 3.3 mm Destructive 294 m/s2 {30 G}, 10 to 55 Hz at double amplitude of 5 mm Ambient temp. (Not freezing and condensing Humidity at low temperature) -40C to +70C -40F to +158F 5 to 85% R.H. Approx. 4 g .14 oz Unit weight Remarks *1 Measurement at same location as "Initial breakdown voltage" section *2 Detection current: 10mA *3 Excluding contact bounce time *4 Half-wave pulse of sine wave: 11ms, detection time: 10s *5 Half-wave pulse of sine wave: 6ms *6 Detection time: 10s *7 Refer to 5. Conditions for operation, transport and storage mentioned in *7 AMBIENT ENVIRONMENT (Page 49) * Telecommunication equipment * Office equipment * Computer peripherals * Security / alarm systems * Medical equipment Vibration resistance Approx. 3 ms Max. 65C with nominal voltage acloss coil and at nominal switching capacity Temperature rise 5 x 105 1 x 105 TYPICAL APPLICATIONS Approx. 3 ms Reset time*3 (latching) (at nominal voltage) Coil (polarized) (at 20C 68F) 2 coil latching 750 Vrms 1,000 Vrms Max. switching current UL/CSA rating Single side stable Min. 1,000 M (at 500 V DC) FCC (Federal Communication Commission) requests following standard as Breakdown Voltage specification. 1500V 750V 10 s 160 s ORDERING INFORMATION Ex DS2Y-S Operating function Nil: Single side stable L2: 2 coil latching L2 DC12 V Coil voltage DC 1.5, 3, 5, 6, 9, 12, 24, 48 V (Note) Standard packing: Carton: 50 pcs. Case: 500 pcs. R Polarity Nil: Standard polarity R: Reverse polarity TYPES AND COIL DATA at 20C 68F Single side stable Nominal operating current mA (10%) Coil resistance, (10%) Nominal operating power mW Maximum allowable voltage, V DC (at 50C 122F) Nominal voltage, V DC Part No. Pick-up voltage, V DC (max.) Drop-out voltage, V DC (min.) 1.5 DS2Y-S-DC1.5V 1.05 0.15 132.7 000011.3 200 03 3.0 DS2Y-S-DC3V 2.10 0.30 066.7 000045.0 200 06 5.0 DS2Y-S-DC5V 3.50 0.50 40. 0,125 200 10 6.0 DS2Y-S-DC6V 4.20 0.60 033.3 0,180 200 12 9.0 DS2Y-S-DC9V 6.30 0.90 022.2 0,405 200 18 12.00 DS2Y-S-DC12V 8.40 1.20 016.7 .0720 200 24 24.00 DS2Y-S-DC24V 16.800 2.40 008.3 2,880 200 48 48.00 DS2Y-S-DC48V 33.600 4.80 006.3 7,680 300 86 2 coil latching Nominal operating current mA (10%) Coil resistance, (10%) Nominal operating power mW Maximum allowable voltage, V DC (at 50C 122F) Nominal voltage, V DC Part No. 1.5 DS2Y-SL2-DC1.5V 1.05 120 00,0.12.5 180 03 3.0 DS2Y-SL2-DC3V 2.10 060 0,050 180 06 5.0 DS2Y-SL2-DC5V 3.50 036 0,139 180 10 6.0 DS2Y-SL2-DC6V 4.20 030 0,200 180 12 9.0 DS2Y-SL2-DC9V 6.30 020 0,450 180 18 12.00 DS2Y-SL2-DC12V 8.40 015 0,800 180 24 24.00 DS2Y-SL2-DC24V 16.800 0007.5 3,200 180 48 48.00 DS2Y-SL2-DC48V 33.600 0007.5 6,400 360 72 Reset set, V DC (max.) Set Reset Set Reset Set Reset DIMENSIONS mm inch Single side stable PC board pattern (Copper-side view) Tolerance: 0.1 .004 8-0.9 dia 8-.035 dia 20 .787 9.3 .366 2.54 .100 5.08 5.08 .200 .200 7.62 .300 2.0 .078 0.6 .024 5.6 .220 7.62 .300 9 11 13 N.O. N.C. COM 16 - N.O. N.C. COM 8 6 4 + 1 7.62 .300 0.6 .024 0.6 .024 (Deenergized position) 2.54 .100 9.9 .390 Schematic (Bottom view) 3.4 .134 matching 16 pin IC socket 0.3 .012 Direction indication* *A polarity bar shows the relay direction. General tolerance: 0.3 .012 PC board pattern (Copper-side view) Tolerance: 0.1 .004 (Reset position) 10-0.9 dia 10-.035 dia 2.54 .100 9.9 .390 9.3 .366 2.54 .100 7.62 .300 0.6 .024 5.08 5.08 5.08 .200 .200 .200 2.54 .100 2.0 .078 0.6 .024 0.6 .024 5.6 .220 7.62 .300 General tolerance: 0.3 .012 3.4 .134 0.3 .012 9 11 13 SET RST COM 15 16 - - Reset 20 .787 Schematic (Bottom view) matching 16 pin IC socket SET RST COM 8 6 4 Set 2 coil latching + + 2 1 Direction indication* *A polarity bar shows the relay direction. Diagram shows the "reset" posetion when terminals 2 and 15 are energized. Energize terminals 1 and 16 to transfer contacts. DS2Y REFERENCE DATA 1. Maximum switching power 2.-(1) Coil temperature rise (Single side stable) 2.-(2) Coil temperature rise (2 coil latching) Ambient temperature: 21C to 25C 70F to 77F Sample: DS2Y-S-DC12V, 5 pcs. (Inside of coil) Ambient temperature: 21C to 25C 70F to 77F Sample: DS2Y-SL2-DC12V, 5 pcs. (Inside of coil) 1,000 V Set coil Reset coil 100 V 10 V 10 mA 10 A Temperature rise, C Temperature rise, C Contact voltage 3A 30 2A 0A 20 100 mA 30 2A 0A 20 100 1A Switching current 3A 0 110 Coil applied voltage, %V 3. Operate/release time (single side stable) 4. Influence of adjacent mounting Ambient temperature: 20C 68F Sample: DS2Y-S-DC12V, 10 pcs. (Without diode) Ambient temperature: 20C 68F Sample: DS2Y-S-DC12V 10 pcs. 100 110 Coil applied voltage, %V TEST METHOD (1) Apply nominal voltage to No. (1) and (3) DS2Y relays. (2) Measure pick-up voltage and drop-out voltage of No. (2) relay when inter-relay distance (R ) changes. Time, ms 4 3 2 Mean value Mean value (2) R (3) OFF R 8 ON 80 100 120 Coil applied voltage, %V ON Pick-up voltage 6 OFF OFF 4 Drop-out voltage ON 2 1 0 (1) OFF 10 0 ON Pick-up/Drop-out voltage, V Operate time Release time Pick-up/Drop-out voltage, V 5 10 (1) OFF 8 (2) R Pick-up voltage (3) OFF R ON ON OFF OFF ON ON 6 4 Drop-out voltage 2 5 10 15 .197 .394 .591 Inter-relay distance, mm inch 0 5 10 15 .197 .394 .591 Inter-relay distance, mm inch For Cautions for Use 6/1/1999 All Rights Reserved, (c) Copyright Matsushita Electric Works, Ltd. Go To Online Catalog