Chemical System:
Lithium / Manganese Dioxide (Li/MnO
2
)
Designation: ANSI / NEDA-5011LC, IEC-CR2430
Battery Voltage: 3.0 Volts
Average Weight: 4.6 grams (0.16 oz.)
Volume: 1.3 cubic centimeters (0.08 cubic inch)
Average Capacity: 290 mAh to 2.0 volts
(Rated at 10k ohms continuous at 21ºC)
Maximum Reverse
Charge Current: 1 microampere
Energy Density: 183 milliwatt hr/g, 647 milliwatt hr/cc
Schedule: Continuous for background
2 seconds X 12 times/day for pulse
Typical Background Drain @ 2.9V (milliamps):
0.29 milliamperes
Typical Pulse Drain @ 2.6V (milliamps):
9.30 milliamperes
Background Load:
10k ohms
Pulse Load:
300 ohms
Copyright © Eveready Battery Co. Inc. - All Rights Reserved
This data sheet contains information specific to batteries manufactured at the time of its publication.
Contents herein do not constitute a warranty.
Typical Drains
24 hours/day 145
Load
(ohms)
20,000
Important Notice
INTERNAL RESISTANCE CHARACTERISTICS
Pulse Test @ 21ºC (70ºF)
Schedule: (microamperes)
at 2.9V
Industry Standard Dimensions in mm (inches)
ENERGIZER NO. CR2430
Simulated Application Test
Cutoff Voltage
2,000 Hours
Estimated Average Service at 21ºC (70ºF)
2.0V
EVEREADY BATTERY CO.
Internet: www.energizer.com 1-800-383-7323 / USA
1-800-383-7323 / CANADA
TYPICAL DISCHARGE CURVE
Simulated Test @ 21ºC (70ºF)
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
0 400 800 1200 1600 2000 2400
Service, Hours
Closed Circuit Voltage
IR CHARACTERISTICS
Pulse Test @ 21ºC (70ºF)
1.8
2.0
2.2
2.4
2.6
2.8
3.0
0 50 100 150 200 250 300
Capacity, mAh
CCV
20
40
60
80
100
120
140
IR, Ohms
BKGND
PULSE
IR
1-800-383-7323 / USA
1-800-383-7323 / CANADA
+ 44 (0) 208 920 2306 / EUROPE
Form No. EBC - 4122C Page 1 of 1