(1/13)
001-03 / 20061027 / e93_tf.fm
• All specifications are subject to change without notice.
Common Mode Choke Coils(Line Filters) for AC Power Supply
Toroidal Core Type TF Series
TDK common mode choke coils(line filters) are used in a wide
range of prevention of electromagnetic interference(EMI) and radio
frequency interference(RFI) from power supply lines and for pre-
vention of multifunctioning of products such as measuring equip-
ment and system equipment.
FEATURES
• Wide range of selection.
• High impedance at applicable frequency.
• High self-resonant frequency.
PRODUCT IDENTIFICATION
(1) Core shape
TF: Toroidal core
(2) Dimensional code
Width×Depth
(3) External shape code
V: Vertical type H: Horizontal type
(4) High µ material
(5) Inductance value
Example) 133:13mH
(6) Rated current value
Example) 3R0:3.0A
(7) Product management number
SELECTION CHART
∗ Handling power=(Inductance value)×(Current)2. It is possible to design within the range below this value.
[Example] The coil for 2A can make even the inductance of 2.5mH or less a product for handling power 10.
Conformity to RoHS Directive
TF V -AYR
-01
(1) (2) (3) (4) (5) (6) (7)
Series Configuration Type Inductance value
min.
Rated current
(A)
Handling power∗
L×I2(mH×A2)
Weight
(g)typ.
Minimum
package quantity
(pieces/box)
TF
Vertical type
TF1813V 2 to 20mH 0.7 to 3.2 20 5 960
TF2518V 0.65 to 9mH 2.5 to 10 50 15 560
TF2721V 1 to 13mH 2.5 to 10 75 20 460
TF3020V 0.35 to 13mH 3 to 20 130 30 440
TF3525V 0.65 to 20mH 3 to 20 195 41 240
Horizontal type
TF1713H 2 to 20mH 0.7 to 3.2 20 5.3 960
TF2520H 0.65 to 9mH 2.5 to 10 50 15 550
TF2722H 1 to 13mH 2.5 to 10 75 20 380
TF3022H 0.35 to 13mH 3 to 20 130 32 320
TF3526H 0.65 to 20mH 3 to 20 195 42 280
Vertical type
(For high frequency)
TF2628V-1H 25 to 65µH 6 to 12 3.65 18 700
TF3524V-1H 25 to 120µH 8 to 20 10.8 40 320
• Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific
bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications.