ECONO-PACTM/OCTA-PAC(R) OCTA-PAC(R) PLUS Power Inductors and Transformers Description RoHS 2002/95/EC * Surface mount magnetics that can be used as single or coupled inductors or 1:1 transformers that provide isolation between two windings * OCTA-PAC's are designed around high frequency, low loss core material * ECONO-PAC's are a lower cost version of OCTA-PAC's offering high saturation flux density, Powder Iron core material * OCTA-PAC PLUS's offer higher current ratings and higher saturation flux densities than OCTA-PAC and ECONO-PAC, Amorphous metal core material * Secure 4 Terminal Mounting * Inductor more versatile inductance combination by series or parallel connections Applications * Computer and portable power devices * LCD panels, DVD players * Inductor: DC-DC converters * Buck, boost, forward, and resonant converters * Noise filtering and filter chokes * Transformers: 1:1 300Vdc isolation, flyback, sepic Environmental Data * Storage temperature range: -40C to +125C * Operating ambient temperature range: -40C to +85C (range is application specific). * Solder reflow temperature: +260C max. for 10 seconds max. Packaging * Supplied in tape and reel packaging, 1100 (EP01, OPA1, and OP01), 800 (EP02, OP02, OPA2, EP03, OPA3, and OP03), and 600 (EP04, OPA4, and OP04) per reel Legend Marking * CTX___-__ (First three digits CTX; Second 2-3 digits = Inductance Value; Last 1-2 digits, product size & type) Product Size/Type * CTX___-1 (-1 = size; no suffix = OCTA-PAC(R)) * CTX___-1P (-1 = size; P suffix = ECONO-PACTM) * CTX___-1A (-1 = size; A suffix = OCTA-PAC(R) PLUS) PARALLEL Part Number CTX0.47-1P-R CTX0.68-1P-R CTX1-1P-R CTX2-1P-R CTX5-1P-R CTX8-1P-R CTX10-1P-R CTX15-1P-R CTX20-1P-R CTX25-1P-R CTX33-1P-R CTX50-1P-R CTX68-1P-R CTX100-1P-R CTX150-1P-R CTX200-1P-R CTX300-1P-R CTX0.47-2P-R CTX0.68-2P-R CTX1-2P-R CTX2-2P-R CTX5-2P-R CTX8-2P-R CTX10-2P-R CTX15-2P-R CTX20-2P-R CTX25-2P-R CTX33-2P-R CTX50-2P-R CTX68-2P-R CTX100-2P-R CTX150-2P-R CTX200-2P-R CTX300-2P-R Open Circuit Inductance H +/-20% .42 .60 1.07 2.02 4.83 8.08 9.62 15.03 20.46 25.40 32.33 50.52 68.40 99.01 150.72 198.41 299.87 .54 .85 1.22 2.18 4.90 7.65 9.83 14.99 19.58 24.79 32.67 49.10 68.85 99.14 148.10 201.59 300.42 Full Load Inductance H min. .31 .43 .73 1.36 3.37 5.31 6.23 9.62 14.12 17.07 22.27 33.57 43.65 63.64 96.64 130.79 190.05 .42 .64 .89 1.56 3.57 5.31 6.73 10.51 13.37 16.60 21.29 35.31 47.93 69.56 100.07 138.49 197.52 SERIES Full Load Current Adc DC Resistance ohms max. 5.50 5.10 4.50 3.40 2.00 1.80 1.70 1.40 1.00 .96 .80 .70 .66 .54 .44 .36 .32 5.90 5.40 5.00 3.90 2.50 2.30 2.10 1.60 1.50 1.40 1.30 .82 .76 .62 .56 .46 .42 .005 .006 .008 .013 .040 .052 .057 .087 .158 .177 .250 .316 .373 .557 .844 1.208 1.525 .006 .007 .008 .014 .032 .040 .045 .085 .097 .109 .126 .305 .362 .541 .665 .951 1.176 Open Circuit Inductance H +/-20% 1.67 2.40 4.28 8.08 19.31 32.33 38.48 60.12 81.83 101.60 129.32 202.07 273.61 396.06 602.87 793.65 1199.46 2.18 3.40 4.90 8.70 19.58 30.60 39.30 59.98 78.34 99.14 130.70 196.38 275.40 396.58 592.42 806.34 1201.70 Full Load Inductance H min. Full Load Current Adc DC Resistance ohms max. 1.25 1.74 2.92 5.44 13.47 21.23 24.94 38.47 56.47 68.29 89.06 134.27 174.61 254.55 386.56 523.16 760.19 1.69 2.55 3.57 6.26 14.26 21.23 26.92 42.02 53.48 66.38 85.17 141.24 191.71 278.22 400.27 553.97 790.08 2.75 2.55 2.25 1.70 1.00 .90 .85 .70 .50 .48 .40 .35 .33 .27 .22 .18 .16 2.95 2.70 2.50 1.95 1.25 1.15 1.05 .80 .75 .70 .65 .41 .38 .31 .28 .23 .21 .021 .025 .032 .054 .161 .207 .227 .348 .634 .708 1.001 1.263 1.490 2.227 3.376 4.831 6.100 .024 .029 .033 .055 .128 .158 .179 .339 .387 .436 .503 1.221 1.445 2.162 2.660 3.804 4.703 ECONO-PACTM/OCTA-PAC(R) OCTA-PAC(R) PLUS Power Inductors and Transformers PARALLEL Part Number CTX0.47-3P-R CTX0.68-3P-R CTX1-3P-R CTX2-3P-R CTX5-3P-R CTX8-3P-R CTX10-3P-R CTX15-3P-R CTX20-3P-R CTX25-3P-R CTX33-3P-R CTX50-3P-R CTX68-3P-R CTX100-3P-R CTX150-3P-R CTX200-3P-R CTX300-3P-R CTX0.47-4P-R CTX0.68-4P-R CTX1-4P-R CTX2-4P-R CTX5-4P-R CTX8-4P-R CTX10-4P-R CTX15-4P-R CTX20-4P-R CTX25-4P-R CTX33-4P-R CTX50-4P-R CTX68-4P-R CTX100-4P-R CTX150-4P-R CTX200-4P-R CTX300-4P-R CTX0.47-1-R CTX0.68-1-R CTX1-1-R CTX2-1-R CTX5-1-R CTX8-1-R CTX10-1-R CTX15-1-R CTX20-1-R CTX25-1-R CTX33-1-R CTX50-1-R CTX68-1-R CTX100-1-R CTX150-1-R CTX200-1-R CTX300-1-R CTX0.47-2-R CTX0.68-2-R CTX1-2-R CTX2-2-R CTX5-2-R CTX8-2-R CTX10-2-R CTX15-2-R CTX20-2-R CTX25-2-R CTX33-2-R CTX50-2-R CTX68-2-R CTX100-2-R Open Circuit Inductance H +/-20% .46 .67 .91 1.85 4.74 8.16 9.79 14.50 20.15 25.33 32.63 50.02 68.84 101.31 149.85 200.10 298.39 .49 .76 1.10 1.95 5.15 7.81 9.88 14.76 20.62 25.65 33.21 48.80 67.37 99.09 149.45 200.11 298.93 .40 .63 .90 2.03 4.90 8.10 10.00 14.40 19.60 25.60 32.40 50.63 67.60 99.23 148.23 202.50 302.50 .42 .75 1.18 2.30 4.70 7.94 10.58 15.23 20.73 24.86 31.77 51.18 67.87 99.45 Full Load Inductance H min. .35 .50 .65 1.24 3.04 4.90 5.71 8.50 13.12 16.16 20.32 33.06 44.15 65.50 90.92 116.51 172.12 .37 .56 .81 1.42 3.56 5.15 6.70 9.52 13.44 17.17 22.93 32.21 43.04 69.54 101.46 131.37 188.03 .26 .41 .56 1.00 2.66 4.08 4.85 8.74 11.54 16.35 19.84 29.34 39.73 58.72 85.16 107.60 191.38 .29 .50 .76 1.27 2.66 4.18 5.18 8.53 12.36 16.09 15.90 28.79 38.71 57.45 SERIES Full Load Current Adc DC Resistance ohms max. 6.20 5.70 5.40 4.60 3.20 2.80 2.70 2.20 1.50 1.40 1.30 .92 .84 .68 .64 .60 .50 7.90 7.20 5.90 4.60 3.30 3.00 2.50 2.30 1.90 1.60 1.30 1.20 1.10 .72 .64 .60 .54 5.50 4.50 4.20 4.10 2.30 2.00 1.90 1.10 1.00 .74 .72 .64 .54 .44 .38 .37 .22 6.50 5.50 4.60 4.50 3.00 2.60 2.50 1.70 1.30 1.00 1.40 .92 .78 .63 .006 .007 .008 .011 .022 .030 .033 .050 .111 .125 .146 .277 .328 .501 .621 .731 .926 .005 .006 .008 .014 .027 .033 .047 .057 .084 .115 .166 .201 .238 .565 .696 .810 1.003 .005 .006 .007 .010 .030 .039 .044 .080 .146 .167 .293 .365 .516 .784 .965 1.142 1.431 .005 .006 .007 .010 .021 .027 .031 .059 .107 .117 .105 .210 .303 .457 Open Circuit Inductance H +/-20% 1.85 2.66 3.63 7.40 18.94 32.63 39.15 58.02 80.59 101.31 130.54 200.10 275.35 405.22 599.40 800.38 1193.55 1.95 3.05 4.39 7.81 20.62 31.23 39.53 59.05 82.47 102.60 132.86 195.20 269.50 396.38 597.80 800.44 1195.72 1.60 2.50 3.60 8.10 19.60 32.40 40.00 57.60 78.40 102.40 129.60 202.50 270.40 396.90 592.90 810.00 1210.00 1.69 3.01 4.70 9.21 18.80 31.77 42.30 60.91 82.91 99.45 127.09 204.73 271.47 397.81 Full Load Inductance H min. Full Load Current Adc DC Resistance ohms max. 1.42 1.98 2.62 4.97 12.15 19.60 22.85 34.01 52.48 64.66 81.30 132.24 176.61 262.02 363.68 466.03 688.50 1.49 2.24 3.24 5.69 14.23 20.61 26.79 38.09 53.76 68.68 91.72 128.83 172.16 278.15 405.83 525.47 752.13 1.05 1.63 2.24 4.01 10.64 16.34 19.40 34.96 46.15 65.42 79.37 117.38 158.92 234.88 340.64 430.39 765.54 1.17 1.98 3.04 5.07 10.65 16.72 20.72 34.10 49.46 64.35 63.59 115.16 154.83 229.79 3.10 2.85 2.70 2.30 1.60 1.40 1.35 1.10 .75 .70 .65 .46 .42 .34 .32 .30 .25 3.95 3.60 2.95 2.30 1.65 1.50 1.25 1.15 .95 .80 .65 .60 .55 .36 .32 .30 .27 2.75 2.25 2.10 2.05 1.15 1.00 .95 .55 .50 .37 .36 .32 .27 .22 .19 .19 .11 3.25 2.75 2.30 2.25 1.50 1.30 1.25 .85 .65 .50 .70 .46 .39 .32 .025 .028 .032 .045 .090 .119 .131 .198 .443 .499 .571 1.108 1.312 2.005 2.483 2.925 3.702 .019 .023 .033 .055 .107 .131 .187 .228 .337 .461 .662 .805 .952 2.259 2.784 3.240 4.011 .020 .024 .028 .040 .122 .157 .176 .319 .583 .668 1.171 1.461 2.064 3.137 3.861 4.567 5.724 .019 .024 .028 .038 .084 .108 .125 .236 .426 .466 .420 .839 1.214 1.828 ECONO-PACTM/OCTA-PAC(R) OCTA-PAC(R) PLUS Power Inductors and Transformers PARALLEL Part Number CTX150-2-R CTX200-2-R CTX300-2-R CTX0.47-3-R CTX0.68-3-R CTX1-3-R CTX2-3-R CTX5-3-R CTX8-3-R CTX10-3-R CTX15-3-R CTX20-3-R CTX25-3-R CTX33-3-R CTX50-3-R CTX68-3-R CTX100-3-R CTX150-3-R CTX200-3-R CTX300-3-R CTX0.47-4-R CTX0.68-4-R CTX1-4-R CTX2-4-R CTX5-4-R CTX8-4-R CTX10-4-R CTX15-4-R CTX20-4-R CTX25-4-R CTX33-4-R CTX50-4-R CTX68-4-R CTX100-4-R CTX150-4-R CTX200-4-R CTX300-4-R Open Circuit Inductance H +/-20% 147.39 198.58 300.80 .38 .60 .86 1.94 4.70 7.78 9.60 15.00 20.18 24.58 32.86 50.78 67.42 101.40 149.78 198.74 301.06 .44 .78 1.23 1.76 4.90 8.28 9.60 14.16 19.60 25.92 33.12 50.18 67.08 99.23 148.23 200.70 298.12 Full Load Inductance H min. 93.46 122.94 169.06 .27 .42 .57 1.05 2.56 3.74 4.38 7.26 10.76 15.64 19.69 27.18 36.53 52.48 97.16 119.18 157.44 .32 .55 .85 1.06 2.59 4.29 4.82 6.76 10.68 13.32 16.82 25.03 35.29 54.56 77.17 111.08 147.92 SERIES Full Load Current Adc DC Resistance ohms max. .43 .39 .38 6.00 5.00 4.80 4.70 3.00 2.80 2.70 2.00 1.50 .98 .96 .94 .80 .70 .38 .39 .40 7.00 6.00 5.00 4.90 4.40 3.50 3.40 3.00 2.10 2.00 1.80 1.50 1.20 .92 .82 .64 .62 .560 .796 1.231 .005 .006 .007 .010 .019 .025 .028 .043 .078 .086 .083 .239 .277 .345 .430 .619 .951 .004 .005 .006 .007 .014 .018 .019 .024 .055 .063 .072 .111 .157 .302 .372 .545 .672 Open Circuit Inductance H +/-20% 589.57 794.30 1203.20 1.54 2.40 3.46 7.78 18.82 31.10 38.40 60.00 80.74 98.30 131.42 203.14 269.66 405.60 599.14 794.98 1204.22 1.76 3.14 4.90 7.06 19.60 33.12 38.42 56.64 78.40 103.68 132.50 200.70 268.32 396.90 592.90 802.82 1192.46 Full Load Inductance H min. Full Load Current Adc DC Resistance ohms max. 373.84 491.76 676.24 1.08 1.67 2.28 4.22 10.26 14.98 17.54 29.06 43.04 62.56 78.77 108.71 146.11 209.93 388.63 476.71 629.75 1.29 2.21 3.41 4.24 10.37 17.14 19.28 27.03 42.73 53.27 67.27 100.11 141.15 218.25 308.69 444.32 591.66 .22 .20 .19 3.00 2.50 2.40 2.35 1.50 1.40 1.35 1.00 .75 .49 .48 .47 .40 .35 .19 .20 .20 3.50 3.00 2.50 2.45 2.20 1.75 1.70 1.50 1.05 1.00 .90 .75 .60 .46 .41 .32 .31 2.241 3.184 4.929 .020 .024 .028 .040 .077 .099 .111 .172 .312 .346 .331 .956 1.109 1.381 1.718 2.475 3.083 .016 .020 .024 .028 .056 .072 .078 .096 .220 .253 .287 .443 .630 1.210 1.488 2.180 2.687 ECONO-PACTM/OCTA-PAC(R) OCTA-PAC(R) PLUS Power Inductors and Transformers Part Number Rated Inductance (H) CTX0.33-1A-R CTX0.68-1A-R CTX1-1A-R CTX2-1A-R CTX5-1A-R CTX8-1A-R CTX10-1A-R CTX15-1A-R CTX20-1A-R CTX25-1A-R CTX33-1A-R CTX50-1A-R CTX68-1A-R CTX100-1A-R CTX150-1A-R CTX200-1A-R CTX300-1A-R CTX0.33-2A-R CTX0.68-2A-R CTX1-2A-R CTX2-2A-R CTX5-2A-R CTX8-2A-R CTX10-2A-R CTX15-2A-R CTX20-2A-R CTX25-2A-R CTX33-2A-R CTX50-2A-R CTX68-2A-R CTX100-2A-R CTX150-2A-R CTX200-2A-R CTX300-2A-R CTX0.33-3A-R CTX0.68-3A-R CTX1-3A-R CTX2-3A-R CTX5-3A-R CTX8-3A-R CTX10-3A-R CTX15-3A-R CTX20-3A-R CTX25-3A-R CTX33-3A-R CTX50-3A-R 0.33 0.68 1.0 2.0 5.0 8.0 10.0 15.0 20.0 25.0 33.0 50.0 68.0 100.0 150.0 200.0 300.0 0.33 0.68 1.0 2.0 5.0 8.0 10.0 15.0 20.0 25.0 33.0 50.0 68.0 100.0 150.0 200.0 300.0 0.33 0.68 1.0 2.0 5.0 8.0 10.0 15.0 20.0 25.0 33.0 50.0 OCL (1) nominal +/-25% (H) 0.402 0.752 1.18 2.30 4.70 7.94 10.58 15.23 20.73 24.86 34.26 51.18 67.87 99.45 147.4 198.6 300.8 0.284 0.675 1.26 1.98 5.06 7.90 11.38 15.48 20.22 25.60 34.84 49.38 66.44 102.38 152.9 197.5 303.7 0.368 0.688 1.08 2.11 5.20 8.43 9.68 15.52 20.81 24.77 33.71 49.71 I sat. (2) Amperes Peak 12.5 9.4 7.5 5.36 3.75 2.88 2.5 2.08 1.79 1.63 1.39 1.14 0.99 0.82 0.67 0.58 0.47 18.8 12.5 9.38 7.50 4.69 3.75 3.13 2.68 2.34 2.08 1.79 1.50 1.29 1.04 0.85 0.75 0.60 15.0 11.3 9.0 6.43 4.09 3.21 3.00 2.37 2.05 1.88 1.61 1.32 Parallel Ratings I rms. (3) DCR (4) Amperes max. @ 20C. 10.0 9.0 7.26 5.64 4.27 3.37 2.84 2.07 1.71 1.46 1.22 0.99 0.92 0.74 0.67 0.62 0.56 10.9 9.4 8.22 6.74 4.34 3.50 2.89 2.69 2.24 1.89 1.56 1.28 1.07 0.75 0.68 0.64 0.58 11.4 9.3 8.38 7.26 5.24 4.23 3.64 3.25 2.43 2.34 1.93 1.56 1) Open Circuit Inductance Test Parameters: 100kHz, 0.250 Vrms, 0.0 Adc Parallel: (1,4 - 3,2) Series: (1 - 3) tie (2 - 4) 2) Peak current for approximately 30% roll-off 3) RMS current, delta temp. of 40 C ambient temperature of 85 C 4) DCR @ 20C 0.0037 0.0046 0.0070 0.012 0.020 0.033 0.046 0.087 0.127 0.173 0.249 0.381 0.437 0.686 0.832 0.963 1.181 0.0033 0.0045 0.0058 0.0090 0.021 0.032 0.047 0.054 0.078 0.111 0.162 0.240 0.342 0.695 0.842 0.950 1.174 0.0032 0.0048 0.0059 0.0079 0.015 0.023 0.032 0.039 0.071 0.076 0.112 0.171 Volt (7) -Sec .93 1.24 1.55 2.17 3.11 4.04 4.66 5.59 6.52 7.14 8.39 10.3 11.8 14.3 17.4 20.2 24.9 .85 1.28 1.71 2.14 3.42 4.27 5.13 5.98 6.84 7.69 8.97 10.7 12.4 15.4 18.8 21.4 26.5 0.97 1.29 1.61 2.26 3.54 4.51 4.83 6.12 7.09 7.73 9.02 11.0 OCL (1) nominal +/-25% (H) 1.61 3.01 4.70 9.21 18.8 31.77 42.30 60.91 82.91 99.45 137.1 204.7 271.5 397.8 589.6 794.3 1203 1.14 2.70 5.06 7.90 20.22 31.60 45.50 61.94 80.90 102.38 139.4 197.5 265.8 409.5 611.8 790.0 1215 1.47 2.75 4.20 8.43 20.81 33.77 38.70 62.09 83.25 99.07 134.8 198.8 I sat. (2) Amperes Peak 6.25 4.69 3.75 2.68 1.88 1.44 1.25 1.04 0.89 0.82 0.69 0.57 0.49 0.41 0.33 0.29 0.23 9.38 6.25 4.69 3.75 2.34 1.88 1.56 1.34 1.17 1.04 0.89 0.75 0.65 0.52 0.43 0.38 0.30 7.50 5.63 4.50 3.21 2.05 1.61 1.50 1.18 1.02 0.94 0.80 0.66 Series Ratings I rms. (3) DCR (4) Amperes max. @ 20C. 4.98 4.48 3.63 2.82 2.13 1.69 1.42 1.03 0.86 0.73 0.61 0.49 0.46 0.37 0.33 0.31 0.28 5.47 4.68 4.11 3.37 2.17 1.75 1.45 1.35 1.12 0.94 0.78 0.64 0.54 0.38 0.34 0.32 0.29 5.72 4.64 4.19 3.63 2.62 2.12 1.82 1.63 1.22 1.17 0.96 0.78 0.015 0.0185 0.0282 0.0470 0.082 0.130 0.183 0.348 0.507 0.693 0.995 1.524 1.749 2.745 3.329 3.854 4.726 0.0132 0.0180 0.0233 0.035 0.084 0.129 0.188 0.218 0.313 0.443 0.649 0.961 1.367 2.778 3.366 3.800 4.697 0.0128 0.0194 0.0238 0.0317 0.061 0.093 0.126 0.158 0.282 0.306 0.449 0.686 Volt (7) -Sec 1.86 2.49 3.11 4.35 6.21 8.08 9.32 11.2 13.0 14.3 16.8 20.5 23.6 28.6 34.8 40.4 49.7 1.71 2.56 3.42 4.27 6.84 8.55 10.3 12.0 13.7 15.4 17.9 21.4 24.8 30.8 37.6 42.7 53.0 1.93 2.58 3.22 4.51 7.09 9.02 9.67 12.2 14.2 15.5 18.0 21.9 5) Hipot rating: winding to winding: 300Vdc min. 6) Turns Ratio: (1-2):(4-3) 1:1 7) Applied volt-time product (v-us) across the inductor. This value represents the applied V-us at 300KHz necessary to generate a core loss equal to 10% of the total losses for a 40C temperature rise. ECONO-PACTM/OCTA-PAC(R) OCTA-PAC(R) PLUS Power Inductors and Transformers Part Number Rated Inductance (H) CTX68-3A-R CTX100-3A-R CTX150-3A-R CTX200-3A-R CTX300-3A-R CTX0.33-4A-R CTX0.68-4A-R CTX1-4A-R CTX2-4A-R CTX5-4A-R CTX8-4A-R CTX10-4A-R CTX15-4A-R CTX20-4A-R CTX25-4A-R CTX33-4A-R CTX50-4A-R CTX68-4A-R CTX100-4A-R CTX150-4A-R CTX200-4A-R CTX300-4A-R 68.0 100.0 150.0 200.0 300.0 0.33 0.68 1.0 2.0 5.0 8.0 10.0 15.0 20.0 25.0 33.0 50.0 68.0 100.0 150.0 200.0 300.0 OCL (1) nominal +/-25% (H) 68.80 99.07 149.7 198.8 296.2 0.313 0.744 1.39 2.18 4.26 8.70 10.53 14.70 19.58 25.14 34.80 50.11 68.21 100.57 153.5 200.4 302.8 I sat. (2) Amperes Peak 1.13 0.94 0.76 0.66 0.54 22.5 15.0 11.25 9.00 6.43 4.50 4.09 3.46 3.00 2.65 2.25 1.88 1.61 1.32 1.07 0.94 0.76 Parallel Ratings I rms. (3) DCR (4) Amperes max. @ 20C. 1.28 1.05 0.86 0.71 0.56 12.2 10.6 9.23 8.38 7.21 5.49 4.67 3.87 3.62 3.02 2.49 2.05 1.70 1.37 1.10 0.92 0.75 1) Open Circuit Inductance Test Parameters: 100kHz, 0.250 Vrms, 0.0 Adc Parallel: (1,4 - 3,2) Series: (1 - 3) tie (2 - 4) 2) Peak current for approximately 30% roll-off 3) RMS current, delta temp. of 40 C ambient temperature of 85 C 4) DCR @ 20C 0.253 0.379 0.571 0.829 1.309 0.0030 0.0040 0.0052 0.0063 0.0085 0.015 0.020 0.029 0.034 0.048 0.071 0.104 0.153 0.235 0.365 0.521 0.787 Volt (7) -Sec 12.9 15.5 19.0 21.9 26.7 0.98 1.47 1.96 2.45 3.44 4.91 5.40 6.38 7.36 8.34 9.81 11.8 13.7 16.7 20.6 23.6 29.0 OCL (1) nominal +/-25% (H) 275.2 396.3 598.7 795.3 1185 1.25 2.98 5.57 8.70 17.05 34.80 42.11 58.81 78.30 100.51 139.2 200.4 272.8 402.3 613.9 801.8 1211 I sat. (2) Amperes Peak 0.56 0.47 0.38 0.33 0.27 11.25 7.50 5.63 4.50 3.21 2.25 2.05 1.73 1.50 1.32 1.13 0.94 0.80 0.66 0.54 0.47 0.38 Series Ratings I rms. (3) DCR (4) Amperes max. @ 20C. 0.64 0.53 0.43 0.35 0.28 6.09 5.28 4.62 4.19 3.61 2.74 2.33 1.94 1.81 1.51 1.25 1.03 0.85 0.69 0.55 0.46 0.37 1.013 1.514 2.283 3.315 5.236 0.0119 0.0158 0.0207 0.0251 0.0339 0.059 0.081 0.117 0.135 0.193 0.283 0.418 0.612 0.939 1.462 2.085 3.148 Volt (7) -Sec 25.8 30.9 38.0 43.8 53.5 1.96 2.94 3.93 4.91 6.87 9.81 10.8 12.8 14.7 16.7 19.6 23.6 27.5 33.4 41.2 47.1 57.9 5) Hipot rating: winding to winding: 300Vdc min. 6) Turns Ratio: (1-2):(4-3) 1:1 7) Applied volt-time product (v-us) across the inductor. This value represents the applied V-us at 300KHz necessary to generate a core loss equal to 10% of the total losses for a 40C temperature rise. ECONO-PACTM/OCTA-PAC(R) OCTA-PAC(R) PLUS Power Inductors and Transformers Mechanical Diagrams CTX 1, 1P, 1A Series CTX 2, 2P, 2A Series CTX 3, 3P, 3A Series CTX 4, 4P, 4A Series Dimensions in Millimeters. wwllyy = (date code) R = revision level ECONO-PACTM/OCTA-PAC(R) OCTA-PAC(R) PLUS Power Inductors and Transformers Packaging Information CTX 1, 1P, 1A Series Direction of Feed Parts packaged on 13" Diameter reel, 1,100 parts per reel. CTX 2, 2P, 2A Series Direction of Feed Parts packaged on 13" Diameter reel, 800 parts per reel. CTX 3, 3P, 3A Series Direction of Feed Parts packaged on 13" Diameter reel, 800 parts per reel. CTX 4, 4P, 4A Series Direction of Feed Dimensions are in millimeters. Parts packaged on 13" Diameter reel, 600 parts per reel. Degree 40 80 20 60 0 40 0.00 0.25 0.50 0.75 20 1.00 1.25 1.50 1.75 2.00 2.25 2.50 Per Unit Full Load Current 0 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 ECONO-PACTM/OCTA-PAC(R) OCTA-PAC(R) PLUS Power Inductors and Transformers 2.50 Per Unit Full Load Current INDUCTANCE VS. CURRENT Performance Characteristics Percentage of Percentage of Inductance Inductance INDUCTANCE VS. CURRENT 10 0 0.00 TEMPERATURE RISE VS. RATED CURRENT ECONO-PAC Max. Ambient plus Rise = 125C 140 ECONO-PAC 120 OCTA-PAC 0.25 0.50 0.75 1.00 OCTA-PAC 1.25 1.50 1.75 2.00 2.25 2.50 Degrees C 100 90 80 70 100 6090 5080 4070 3060 2050 1040 030 0.00 20 100 60 40 20 Per Unit Full Load Current 0.25 0.50 0.75 1.00 1.25 1.50 ECONO-PAC & OCTA-PAC 80 1.75 2.00 2.25 0 0.00 2.50 0.25 0.50 Per Unit Full Load Current Percentage of Inductance Percentage Change Percentagein Change Inductance in Inductance OCTA-PAC OCTA-PAC -15 +5 +25 +45 +65 +85 +105 +125 Temperature in Degrees C. -35 -15 +5 +25 +45 +65 1.50 1.75 2.00 2.25 2.50 90 * CURRENT LIMITATION: ECONO-PAC The 80 maximum allowable currents are defined by the internal 70 "hot-spot" temperatures which are limited to 130C, including 60 ambient. ECONO-PAC -35 1.25 * INDUCTANCE FREQUENCY RESPONSE: VS. CURRENT Wide-band frequency response to 1 megaHertz. 100 INDUCTANCEECONO-PAC VS. TEMPERATURE -10 -12 -14 1.00 * INDUCTANCE VS. CURRENT: Inductance will fall off as DC Current is increased. (See Inductance vs. Current graph). INDUCTANCE VS. TEMPERATURE +8 +6 +4 +2+8 +0+6 -2+4 -4+2 -6+0 -8 -2 -10 -4 -12 -6 -14 -8 0.75 Per Unit Full Load Current +85 +105 OCTA-PAC(R) PLUS Typical Inductance vs. DC Temperature in Degrees C. Current 50 40 30 20 10 0 0.00 OCTA-PAC 0.25 0.50 0.75 +125 1.00 1.25 1.50 1.75 2.00 2.25 2.50 Per Unit Full Load Current OCTA-PAC(R) PLUS Winding Loss Derating with Core Loss 100 % of Losses from Irms (maximum) Percentage Change in Inductance 0 20 90 40 50 80 INDUCTANCE VS. TEMPERATURE 60 92 94 95 40 96 30 97 20 98 10 99 0 10 0 20 40 60 80 100 % of Isat PM-4314 3/07 (c) Cooper Electronic Technologies 2007 120 140 160 180 200 0K Hz 10 Hz 0K Hz 0K 20 50 30 ECONO-PAC 1M % of OCL 90 50 Hz +8 +6 +4 +2 +0 -2 -4 -6 -8 -10 -12 -14 80 60 0K Hz 70 70 OCTA-PAC 20 -35 30 40 -15 50 60 +5 80 100 +25 +45200 300 +65 400 500 600 +85 800 1000 +105 +125 % of Applied Volt--Second Rating Temperature in Degrees C. Visit us on the Web at www.cooperbussmann.com 1225 Broken Sound Pkwy. Suite F Boca Raton, FL 33487 Tel: +1-561-998-4100 Toll Free: +1-888-414-2645 Fax: +1-561-241-6640 This bulletin is intended to present product design solutions and technical information that will help the end user with design applications. Cooper Electronic Technologies reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Electronic Technologies also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Life Support Policy: Cooper Electronic Technologies does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user.