DTE60 Series DC-DC Converter
xxx Series
www.xppower.com
1
Models & Ratings
Notes
1. Input current measured at nominal input voltage.
2. Typical values.
3. For optional version fitted with Din Clip add suffix ‘-D’ e.g. DTE6024S24-D.
4. Input current is typically 3 mA at nominal input voltage when output is remotely
turned off.
Fully Encapsulated Chassis Mount
Wide 4:1 Input Range
-40 °C to +95 °C Operating Temperature
High Efficiency up to 92 %
Optional DIN Rail Version
Remote On/Off
EN55032 Conducted Level A With No External Components
3 Year Warranty
Dimensions:
DTE60:
4.41 x 2.67 x 1.5” (112 x 67.8 x 38 mm)
60 Watts
Input Voltage Output Voltage Output Current Input Current(1,4) Maximum
Capacitive Load Efficiency(2) Model Number(3)
No Load Full Load
24 V
(9-36 V)
5.1 V 12.0 A 100 mA 2.83 A 20,400 µF 90% DTE6024S5V1
12.0 V 5.0 A 100 mA 2.75 A 3540 µF 91% DTE6024S12
24.0 V 2.5 A 110 mA 2.75 A 890 µF 91% DTE6024S24
48.0 V 1.25 A 60 mA 2.75 A 220 µF 91% DTE6024S48
48 V
(18-75 V)
5.1 V 12.0 A 40 mA 1.40 A 20,400 µF 91% DTE6048S5V1
12.0 V 5.0 A 60 mA 1.36 A 3540 µF 92% DTE6048S12
24.0 V 2.5 A 60 mA 1.37 A 890 µF 91% DTE6048S24
48.0 V 1.25 A 50 mA 1.37 A 220 µF 91% DTE6048S48
1. All dimensions are in inches (mm)
2. Weight: 0.6 lbs (300 g) approx
3. Weight for -D version: 0.706 lbs
(353 g) approx
4. Terminal wire size 1.5 mm2max
5. Screw terminal torque 4.5 to 6.2 lb-in
(0.5 to 0.7 Nm)
6. Case tolerance: ±0.02 (±0.5)
Notes
Mechanical Details
Pin Connections
Pin Function
1 Remote On/Off
2 -Vin
3 +Vin
4 No Connection
5 +Vout
6 No Connection
7 -Vout
8 No Connection
DC-
ON
4 x ø3.5
8
7
6
5
4
3
2
1
Indication LED
Top View
3.94 (100.0)
4.41 (112.0)
Power “Good”
Indicator
1.97
(50.0)
2.67
(67.8)
3.54 (90.0) 0.43 (11.0)
1.50
(38.0)
0.66 (16.8)
0.20 (5.0)
3.54 (90.0) 0.43 (11.0)
1.50
(38.0)
0.66
(16.8)
0.12
(3.0) 0.43
(11.0)
0.20
(5.0)
-D Version
DTE60 Series
2
DC-DC Converter
Input
Output
Characteristic Minimum Typical Maximum Units Notes & Conditions
Output Voltage 5.1 48 V See Models and Ratings table
Initial Set Accuracy ±1 ±2 %
Minimum Load 0ANo minimum load required
Start Up Delay 50 ms
Line Regulation ±0.2 ±1.5 %
Load Regulation ±0.5 ±1.0 % 0 - 100% load
Transient Response 5 % deviation Recovery to within 1% in <250 µs for a 50% load change
at 0.25 A/µs rate
Ripple & Noise
100
150
200
mV pk-pk
5.1 V model, 20 MHz bandwidth
12 V & 48 V models, 20 MHz bandwidth
48 V model, 20 MHz bandwidth
Short Circuit Protection Trip & Restart (hiccup mode), auto recovery
Overload Protection 150 % Trip & Restart (hiccup mode)
Overvoltage Protection 120 % Zener diode clamp
Temperature Coefficient 0.03 %/ ˚C
Characteristic MinimumTypical MaximumUnitsNotes & Conditions
Input Voltage Range936 VDC24 V nominal
1875 VDC48 V nominal
Input Current See Models and Ratings table
Inrush Current A
Input FilterPi type
Undervoltage Lockout On at >9 V. Off <7.5 V24 V models
On at >18 V. Off <16.0 V48 V models
Input Surge50 VDC24 V models for 100 ms
100VDC48 V models for 100 ms
Remote On/OffOn: Logic High (3.5-12 V) or open circuit
Off: Logic Low (<1.2 V) or short pin 1 to pin 2
General
Characteristic Minimum Typical Maximum Units Notes & Conditions
Efficiency 91 % See Models and Ratings table
Isolation 2500 VDC For 60 s
Isolation Resistance 1000 MΩAt 500 VDC
Input to Output Capacitance 3000 pF
Switching Frequency 210 kHz
Power Density 3.4 W/in3
Mean Time Between Failure 240 kHrs MIL-HDBK-217F, +25 °C GB
Weight 0.6 (300) lb (g)
Environmental
Characteristic Minimum Typical Maximum Units Notes & Conditions
Operating Temperature -40 +95 °C See derating curve
Storage Temperature -50 +125 °C
Case Temperature 95 °C
Thermal Impendance
(Case to Ambient)
3.5
°C/W
Natural convection
1.95 100 LFM
1.61 200 LFM
1.33 400 LFM
Humidity 5 95 %RH Non-condensing
Cooling Natural convection
Shock ±3 shocks in each plane, total 18 shocks of 30 g : 11 ms halfsine. Conforms to EN60068-2-27 & EN60068-2-47
Vibration 10-500 Hz at 2 g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6
3
0
-40 95
20
40
60
80
100
Ambient Temperature (°C)
: 74 °C for DTE6024S12, S24, S48
DTE6048S5V1, S24, S48
: 76 °C for DTE6048S12
: 71 °C for DTE6024S5V1
Load (%)
A
A
DTE60 Series
www.xppower.com
DC-DC Converter
3
EMC: Immunity
Phenomenon Standard Test Level Criteria Notes & Conditions
Immunity EN55024
ESD Immunity EN61000-4-2 ±4 kV Contact, ±8 kV Air A
Radiated Immunity EN61000-4-3 10 V/m A
EFT/Burst EN61000-4-4 3A
Surges EN61000-4-5 3A
Conducted Immunity EN61000-4-6 10 Vm A
Magnetic Fields EN61000-4-8 30 A/m A
EMC: Emissions
Phenomenon Standard Test Level Notes & Conditions
Conducted EN55032 Level A With no external components
Radiated EN55032 Level A See application notes
Application Notes
C2
Pin 3
Pin 2
+Vin
-Vin
+Vout
-Vout
L1
C1
C3
Pin 5
Pin 7
Radiated Emissions
Derating Curve for Convection Cooling
Safety Approvals
Safety Agency Safety Standard Notes & Conditions
CB IEC60950-1 ITE
ULUL60950-1 ITE
Model L1 C1 C2 C3
DTE6024SXX 175 µH 4.7 µF/50 V 220 pF/3 KV 220 pF/3 KV
DTE6048SXX 175 µH 3.3 µF/100 V 220 pF/3 KV 220 pF/3 KV
DTE60 Series
www.xppower.com
DC-DC Converter
02 May 18
1. All dimensions are in inches (mm)
2. Weight: 0.6 lbs (300 g) approx
3. Weight for -D version: 0.706 lbs (353 g) approx
4. Terminal wire size 1.5 mm2max
5. Screw terminal torque 4.5 to 6.2 lb-in (0.5 to 0.7 Nm)
6. Case tolerance: ±0.02 (±0.5)
Notes
Mechanical Details
DC-
ON
4 x ø3.5
8
7
6
5
4
3
2
1
Indication LED
Top View
3.94 (100.0)
4.41 (112.0)
Power “Good”
Indicator
1.97
(50.0)
2.67
(67.8)
3.54 (90.0) 0.43 (11.0)
1.50
(38.0)
0.66 (16.8)
0.20 (5.0)
3.54 (90.0) 0.43 (11.0)
1.50
(38.0)
0.66
(16.8)
0.12
(3.0) 0.43
(11.0)
0.20
(5.0)
-D Version
Pin Connections
Pin Function
1 Remote On/Off
2 -Vin
3 +Vin
4 No Connection
5 +Vout
6 No Connection
7 -Vout