Rev. 04.13.06
LPT40 Series
1of 3
Embedded Power for
Business-Critical Continuity
LPT40 Series
40 Watts
Special Features
• Universal input
• 3" x 5" footprint
• Less than 1U high
• Remote sense on main output
• Terminal Block option (-T)
• Built-in EMI filter
• Low output ripple
• Adjustable main output
• Overvoltage protection
•Overload protection
• 110 KHz switching frequency
• LPX40 enclosure kit available
Total Power: 40 - 55 Watts
Input Voltage: 85 - 264 VAC
120 - 300VDC
# of Outputs: Triple
Electrical Specifications
Safety
Input
Input range 85-264 VAC
120-300 VDC
Frequency 47-440 Hz
Inrush current <18A peak @ 115VAC;
<36A peak @ 230VAC, cold start @ 25°C
Input current 1A max. (RMS) @ 115VAC
Efficiency 70% typical at full load (60% for LPT41)
EMI FCC Class B conducted; CISPR 22 Class B conducted
EN55022 Class B conducted;
VDE 0878 PT3 Class B conducted
Safety ground
leakage current
<0.5 mA @ 50/60 Hz, 264 VAC input
Output
Maximum Power 40W for convection (LPT41, 25W);
55W with 30CFW forced air (LPT41, 41W)
Cross regulation ±2% on output 1; ±5% on outputs 2, 3
Adjustment range -5, +10% minimum
Hold-up time 20ms @ 40W load, 115 VAC nominal line
Overload protection Short circuit protection on all outputs. Case overload
protected @ 110% to 145% above peak rating
Overvoltage protection 5.7 to 6.7 VDC on the main output
LPT41: 3.6 to 4.6VDC
Remote sense Compensates for 0.5 V lead drop min. Will operate without
remote sense connected. Reverse connection protected.
UL UL1950
E132002
CSA CSA 22.2-234 Level 3
LR53982C
NEMKO EN 60950/EMKO-TUE
P95100411
(74-sec) 203
CB Certificate and report
1118, 1122, 1123, 1124
CE Mark (LVD)