2
A8LA8L
■Ratings
Note: 1. The non-inductive lamp load has an inrush current 10 times steady current.
2. The inductive load has a power factor of 0.4 minimum (AC).
3. The motor load has an inrush current 6 times steady current.
The above ratings were tested under the following conditions:
1. Ambient temperature:20±2°C
2. Ambient humidity:65±5%RH
3. Switching frequency:7 times/min
■Approved Safety Standards
UL, cUL (UL1054/CSA C22.2 No. 55)
10 A, 125 VAC; 10 A, 250 VAC
TÜV (EN61058-1)
10 (8) A, 250 VAC
■Characteristics
Note: Consult your OMRON representative for details of performance characteristics with respect to individual standards.
■Dimensions (Unit: mm)
Note: The following illustrations and drawings are for 2 poles (DPST) models, 1 pole (SPST) models have single side terminals.
Solder Terminals ■Operating Characteristics
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Rated load Non-inductive Inductive
Resistive load Lamp load Inductive load Inductive motor load
125 VAC 10 A 10 A 8 A 8 A
250 VAC 10 A 10 A 8 A 8 A
Permissible operating
frequency Mechanical 20 operations/min max.
Electrical 7 operations/min max.
Insulation resistance 100 MΩ min. (500 VDC)
Dielectric strength
Between terminals
of the same polarity 2,000 VAC, 50/60 Hz, for 1 min
Between terminals
of the different
polarity 2,000 VAC, 50/60 Hz, for 1 min
Between charged
metal parts and the
ground terminal 4,000 VAC, 50/60 Hz, for 1 min
Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance Malfunction 300 m/s2
Destruction 500 m/s2
Durability Mechanical 50,000 operations min.
Electrical 10,000 operations min.
Inrush current 100 A max. (8.3 ms max.)
Ambient operating temperature –20 to +55°C (with no icing or condensation)
Ambient operating humidity 45 to 85%RH