Data Sheet
October 1, 2009
Austin LynxTM II 12 V SMT Non-Isolated Power Modules:
8.3 – 14.0Vdc Input; 0.75Vdc to 5.5Vdc Output; 10A output current
LINEAGE POWER 14
Feature Descriptions (continued)
Voltage Sequencing
Austin LynxTM II series of modules include a sequencing
feature, EZ-SEQUENCE that enables users to implement
various types of output voltage sequencing in their
applications. This is accomplished via an additional
sequencing pin. When not using the sequencing feature,
either tie the SEQ pin to VIN or leave it unconnected.
When an analog voltage is applied to the SEQ pin, the
output voltage tracks this voltage until the output reaches
the set-point voltage. The SEQ voltage must be set
higher than the set-point voltage of the module. The
output voltage follows the voltage on the SEQ pin on a
one-to-one volt basis. By connecting multiple modules
together, customers can get multiple modules to track
their output voltages to the voltage applied on the SEQ
pin.
For proper voltage sequencing, first, input voltage is
applied to the module. The On/Off pin of the module is
left unconnected (or tied to GND for negative logic
modules or tied to VIN for positive logic modules) so that
the module is ON by default. After applying input voltage
to the module, a minimum of 10msec delay is required
before applying voltage on the SEQ pin. During this time,
potential of 50mV (± 10 mV) is maintained on the SEQ
pin. After 10msec delay, an analog voltage is applied to
the SEQ pin and the output voltage of the module will
track this voltage on a one-to-one volt bases until output
reaches the set-point voltage. To initiate simultaneous
shutdown of the modules, the SEQ pin voltage is lowered
in a controlled manner. Output voltage of the modules
tracks the voltages below their set-point voltages on a
one-to-one basis. A valid input voltage must be
maintained until the tracking and output voltages reach
ground potential.
When using the EZ-SEQUENCETM feature to control
start-up of the module, pre-bias immunity feature during
start-up is disabled. The pre-bias immunity feature of the
module relies on the module being in the diode-mode
during start-up. When using the EZ-SEQUENCETM
feature, modules goes through an internal set-up time of
10msec, and will be in synchronous rectification mode
when voltage at the SEQ pin is applied. This will result in
sinking current in the module if pre-bias voltage is present
at the output of the module. When pre-bias immunity
during start-up is required, the EZ-SEQUENCETM feature
must be disabled. For additional guidelines on using EZ-
SEQUENCETM feature of Austin LynxTM II, contact the
Lineage Power technical representative for preliminary
application note on output voltage sequencing using
Austin Lynx II series.
Remote Sense
The Austin LynxTM SMT power modules have a Remote
Sense feature to minimize the effects of distribution
losses by regulating the voltage at the Remote Sense pin
(See Figure 31). The voltage between the Sense pin and
Vo pin must not exceed 0.5V.
The amount of power delivered by the module is defined
as the output voltage multiplied by the output current (Vo
x Io). When using Remote Sense, the output voltage of
the module can increase, which if the same output is
maintained, increases the power output by the module.
Make sure that the maximum output power of the module
remains at or below the maximum rated power. When
the Remote Sense feature is not being used, connect the
Remote Sense pin to the output pin.
VO
COM
VIN(+ )
COM
RLOAD
Rcontact Rdistribution
Rcontact Rdistribution
Rcontact
Rcontact
Rdistribution
Rdistribution
Sense
Figure 31. Remote sense circuit configuration