FIBER UNITS WITH 90°BEND IN STAINLESS
STEEL TUBE
Applicable Models
E32-TC200B/TC200F/DC200F
Appearance
Stainless Steel Tube with a 90°Bend at the Tip
R
Length
1
Bending radius
1(
1)
R5.0 10.0 mm 15.0 mm
R7.5 12.5 mm 17.5 mm
R 10.0 15.0 mm 20.0 mm
R 12.5 17.5 mm 22.5 mm
The length overall is 120 mm max.
Note: If larger
1is required, use the E39-F11 Sleeve Bender.
Stainless Steel Tube with a 90°Bend at the Base
R
Length
2
Bending radius
1(
1)
R5.0 5.0 mm 10.0 mm
R7.5 7.5 mm 17.5 mm
R 10.0 10.0 mm 20.0 mm
R 12.5 12.5 mm 22.5 mm
The length overall is 120 mm max.
Note: If larger
2is required, use the E39-F11 Sleeve Bender.
Sensing Distance for Tubes with 90°Bends
Part Number Amplifier Bending Radius
Standard R5.0 R7.5 R10.0 R12.5
E32-TC200B E3X-H11 400 mm 260 mm 330 mm 360 mm 400 mm
E3X-A
180 mm 110 mm 140 mm 160 mm 180 mm
E32-TC200F E3X-H11 100 mm 55 mm 100 mm 100 mm 100 mm
E3X-A
50 mm 30 mm 50 mm 50 mm 50 mm
E32-DC200F E3X-H11 36 mm 30 mm 36 mm 36 mm 36 mm
E3X-A
18 mm 10 mm 18 mm 18 mm 18 mm
FIBER UNIT WITH LONGER FIBER
Applicable Models
E32-TC200/-DC200
E32-TC200B/-DC200B
E32-TC200E/-DC200E
E32-TC200F/-DC200F
E32-TC200A
Appearance
The length can be ordered in increments of 1 m between
6 m min. and 20m max.. (2-m and5-m fiber length types are
standard for E32-TC200, E32-DC200.)
HANDLING
E32-D51/-T51 Heat-resisting Fiber
The bending radius of the fibers should be 35 mm min.
Connecting fibers via the E39-F10 Fiber Connector is not possible.
The withstand temperature of the Heat-Resisting Fibers is 150°C
max. In continuous operation, the ambient temperature should be
130°Cmax.
E32-T14/-T51
If the sensor is ON because some object in front of the lenses re-
flects light, attach the black seals (sold together) to the lenses.
E32-T14/-G14
Seal
E32-L25 (A) Wafer Sensor
Insert the fiber with a white line into the light projection side of the
Amplifier.
The tightening force of the sensor head is 8 kgf
cm (0.75 N
m).
Avoid places where water could be sprayed onto the E32-L25(A).
E32-T16 Slit Seal (Attachment)
Peel the E32-T16 Slit Seal off the ground paper and affix the Slit
Seal to the sensing face of the sensor so that the corners of the Slit
Seal fit in with thecorners of the sensing face. Tosense anobject at
a distance of 30 cm max., a 0.5-mm wide Slit Seal must be used.
E32-T16 Sensing Head Attachment slit
E32 E32