aHWS1
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
●Environmentally-friendly:
High-efficiencytechnologyreducespowerloss
byheatgeneration.Fanstopping inpower-offby
externalcontrolreduces acousticnoiseand saves
energy.
●Easytouse:Allmodelsinthesamehightof82mm.
Mountablein2U-heightrackswithoutdeadspace.
●Safety and reliability:Safetyterminalcover-
ingcurrentflowing partsecuressafetyforusers.
Noscrew-droppingdesignpreventsfrom losing
screwsduringmaintenanceoperation.
■Applications
■Features
HWS SERIES
■ProductLineup
SingleOutput300W-1800W
Y
E
A
R
S
warranty
5
Output
Voltage
300W 600W 1000W 1500W 1800W
OutputCurrent
(Peak) Model
OutputCurrent
(Peak) Model
OutputCurrent
(Peak) Model
OutputCurrent
(※)
(Peak) Model
OutputCurrent
(Peak) Model
3.3V 60A HWS300-3 120A HWS600-3 200A HWS1000-3 300A/300A HWS1500-3 300A
HWS1800T-3
5V 60A HWS300-5 120A HWS600-5 200A HWS1000-5 300A/300A HWS1500-5 300A
HWS1800T-5
6V 167A HWS1000-6
250A/250A(300A)
HWS1500-6
250A(300A)
HWS1800T-6
7.5V
134A(160A)
HWS1000-7
200A/200A(240A)
HWS1500-7
200A(240A)
HWS1800T-7
12V 27A HWS300-12 53A HWS600-12
88A(100A) HWS1000-12
125A/125A
HWS1500-12
125A(150A)
HWS1800T-12
15V 22A HWS300-15 43A HWS600-15 70A(80A)
HWS1000-15
100A/100A
HWS1500-15
100A(120A)
HWS1800T-15
24V
14A(16.5A)
HWS300-24 27A(31A) HWS600-24
46A(58.5A)
HWS1000-24
65A/70A(105A)
HWS1500-24
75A(105A)
HWS1800T-24
36V
30.7A(39A)
HWS1000-36
42A/46.5A(70A)
HWS1500-36 50A(70A)
HWS1800T-36
48V 7A HWS300-48 13A HWS600-48
23A(29.2A)
HWS1000-48
32A/32A HWS1500-48
37.5A(52.5A)
HWS1800T-48
60V
18.4A(23.4A)
HWS1000-60
25.6A/28A(42A)
HWS1500-60 30A(42A)
HWS1800T-60
No.14-M95
(HWS300,600 24Vout only)
(※)
(100Vin/200Vin)
■Features
Thismeansthat,inconformitywithEUDirective2002/95/
EC,lead,cadmium,mercury, hexavalentchromium, and
specificbromine-basedflameretardants, PBBand PBDE,
havenotbeenused,exceptforexemptedapplications.
■
ConformitytoRoHSDirective
■Modelnamingmethod
HWS300−5/□□
Blank:Withcover,
forcedaircoolingwithbuilt-infan
PV:
Outputvoltageadjustablebyexternal
voltage12Vout+modelsforHWS300,
600only.
(Supportedbystandardmodelsfor
HWS1000andabove.)
Nominaloutputvoltage
ex.3:3.3V,5:5V,48:48V
Seriesname Outputpower
Contents
●HWS/HD  ☞ aHWS13Page
●HWS/ME  ☞ aHWS25Page
●BlockDiagram,SequenceTimeChart ☞ aHWS35Page
●HWS,HWS/HD,HWS/MEInstructionManual  ☞ aHWS39Page
●HWS-P  ☞ aHWS79Page
HWS
web160112
aHWS2
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
ITEMS/UNITS MODEL HWS300-3 HWS300-5 HWS300-12 HWS300-15 HWS300-24 HWS300-48
Input
Voltage Range (*2) V AC85 - 265 or DC120 - 330
Frequency (*2) Hz 47 - 63
Power Factor (100/200VAC)(typ) (*1)
0.99 / 0.95
Efficiency (100/200VAC)(typ) (*1) 74 / 77 79 / 82 80 / 83 82 / 85
Current (100/200VAC)(typ) (*1) A 2.7 / 1.4 3.8 / 1.9 4.1 / 2.1
Inrush Current (100/200VAC)(typ)
(*3)
A 20 / 40
Leakage Current (*10) mA Less than 0.75. (0.2 (typ) at 100VAC / 0.44 (typ) at 230VAC)
Output
Nominal Voltage VDC 3.3 5 12 15 24 48
Maximum Current (*13) A 60 27 22 14 (16.5) 7
Maximum Power W 198 300 324 330 336
Maximum Line Regulation (*5) mV 20 48 60 96 192
Maximum Load Regulation (*6) mV 30 72 90 144 288
Temperature Coefficient Less than 0.02% /
Maximum Ripple & Noise (0d
Tad70) (*4)
mVp-p
120 150 350
Maximum Ripple & Noise (10d
Ta< 0) (*4)
mVp-p
180 200 400
Hold-up Time (typ) (*9) ms 20
Voltage Adjustable Range VDC 2.64 - 3.96 4.0 - 6.0 9.6 - 14.4 12.0 - 18.0 19.2 - 28.8 38.4 - 52.8
Function
Over Current Protection (*7) A >63 > 28.4 >23.1 >16.7 >7.4
Over Voltage Protection (*8) V 4.13 - 4.95 6.25 - 7.25 15.0 - 17.4 18.8 - 21.8 30.0 - 34.8 55.2 - 64.8
Remote Sensing Possible
Remote ON/OFF Control Possible
Parallel Operation Possible
Series Operation Possible
Monitoring Signal PF (Open collector output)
Line DIP Designed to meet SEMI-F47 (200VAC Line only)
Environment
Operating Temperature (*11) -10 to +70 (-10 to +50: 100%, +70: 50%)
Storage Temperature -30 to +85
Operating Humidity RH 10 - 90 (No dewdrop)
Storage Humidity RH 10 - 95 (No dewdrop)
Vibration At no operating, 10 - 55Hz (sweep for 1min) 19.6m/s² constant,
X, Y, Z 1hour each.
Shock (In package) Less than 196.1m/
Cooling Forced air by blower fan
Isolation
Withstand Voltage Input - FG : 2.5kVAC (20mA), Input - Output : 3kVAC (20mA)
Output - FG: 500VAC (100mA), Output-CNT: 100VAC(100mA) for 1min
Isolation Resistance More than 100M: Output - FG : 500VDC
More than 10M: Output -CNT : 100VDC at 25 and 70%RH
Standards
Safety Standards (*12) Approved by UL60950-1, UL508 (24V model only), CSA C22.2 No.60950-1,
CSA C22.2 No.14-M95 (24V model only), EN60950-1, EN50178 Designed to meet DENAN
PFHC Designed to meet IEC61000-3-2
EMI Designed to meet EN55011/EN55022-B, FCC-B, VCCI-B
Immunity Designed to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level3),
-5(Level 3,4), -6(Level 3), -8(Level 4), -11
Mechani-
cal
Weight (typ) g 1000
Size (W x H x D) mm 61 x 82 x 165 (Refer to outline drawing)
(*1) At 100/200VAC, Ta=25 and maximum output power.
(*2) For cases where conformance to various safety specs (UL, CSA, EN) are required, to be described as 100-240VAC (50/60Hz).
(*3) Not applicable for the inrush current to noise filter for less than 0.2ms.
(*4) Measure with JEITA RC-9131A probe, bandwidth of scope :100MHz.
(*5) 85 - 265VAC, constant load.
(*6) No load-full load, constant input voltage.
(*7) 3.3, 5V model: Constant current limit and hiccup with automatic recovery.
12 - 48V model: Constant current limit with automatic recovery.
Avoid to operate at over load or short circuit condition for more than 30 seconds.
(*8) OVP circuit will shut the output down, manual reset (CNT reset or Re power on).
(*9) At 100/200VAC, nominal output voltage and maximum output current.
(*10) Measured by the each measuring method of UL, CSA, EN and DENAN (at 60Hz), Ta=25 .
(*11) Ratings - Derating at standard mounting. Refer to output derating curve.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
(*12) As for DENAN, designed to meet at 100VAC.
(*13) ( ): Peak output current at 200VAC. Operaing time at peak output is less than 10 sec, duty is less than 35%.
Pleasereferto"TDK-Lambda
EMCFilters"catalog.
RecommendedEMCFilter
RSEN-2006
HWS 300

aHWS3
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
[umm]
AIRFLOW
FAN
105±0.5
120±0.525
22MAX
18MAX
5MAX
165±1
25
61±1
3-M4
4-M4
NAMEPLATE
(14.6)
(46.9)
82±1
60±0.5
40±0.510.5 11
(66.6)
(34.5) 11 1114
(47)
(9.5)
10 10
15
7.2
(10.7)
(8.9)
7.3
8-M4TAPPEDHOLES(TAPPEDATTHEBOTTOMCHASSIS)
SCREWPENETRATIONDEPTHMAX.6mm
SCREWPENETRATIONDEPTHMAX.6mm
【HWS300】
0
20
40
60
80
100
120
-100 10203040506070 80
Ta(℃)
LOAD(%)
MOUNTINGA
(STANDARDMOUNTING)
MOUNTINGB DONTUSE DONTUSE
==ACCESSORIES==
COVERFORBARRIERTERMINALSTRIP------1
(ATTACHEDONTERMINALATSHIPMENT)
SHORTPIECE---------------------1
SHORTING+Vm―+S,-Vm―S.CNT―TOG
(ATTACHEDONCN1ATSHIPMENT)
PARTDESCRIPTION
SOCKETHOUSING
TERMINALPINS
HANDCRIMRINGTOOL
PARTNAME
PHDR-12VS
SPHD-002T-P0.5(AWG28-24)
SPHD-001T-P0.5(AWG26-22)
YRS-620(SPHD-002T-P0.5)
YC-610R(SPHD-001T-P0.5)
MANUFACT
JST
JST
JST
==MATCHINGHOUSINGS,PINS&TOOL==
PARTNAME
MANUFACT
S12B-PHDSS JST
==SIGNALCONNECTORUSED==
PARTDESCRIPTION
PINHEADER
HWS 300
!"
!"
aHWS4
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
ITEMS/UNITS MODEL HWS600-3 HWS600-5 HWS600-12 HWS600-15 HWS600-24 HWS600-48
Input
Voltage Range (*2) V AC85 - 265 or DC120 - 330
Frequency (*2) Hz 47 - 63
Power Factor (100/200VAC)(typ) (*1)
0.99 / 0.95
Efficiency (100/200VAC)(typ) (*1) 75 / 78 80 / 83 81 / 84 82 / 85 83 / 86
Current (100/200VAC)(typ) (*1) A 5.4 / 2.6 7.5 / 3.6 8.1 / 3.9
Inrush Current (100/200VAC)(typ) (*3)
A 20 / 40
Leakage Current (*10) mA Less than 0.75. (0.2 (typ) at 100VAC / 0.44 (typ) at 230VAC)
Output
Nominal Voltage VDC 3.3 5 12 15 24 48
Maximum Current (*13) A 120 53 43 27(31) 13
Maximum Power W 396 600 636 645 648 624
Maximum Line Regulation (*5) mV 20 48 60 96 192
Maximum Load Regulation (*6) mV 30 72 90 144 288
Temperature Coefficient Less than 0.02 /
Maximum Ripple & Noise (0d
Tad70) (*4)
mVp-p
120 150 350
Maximum Ripple & Noise (-10d
Tad 0) (*4)
mVp-p
180 200 400
Hold-up Time (typ) (*9) ms 20ms
Voltage Adjustable Range VDC 2.64 - 3.96 4.0 - 6.0 9.6 - 14.4 12.0 - 18.0 19.2 - 28.8 38.4 - 52.8
Function
Over Current Protection (*7) A >126 >55.7 >45.2 >31.4 >13.7
Over Voltage Protection (*8) VDC 4.13 - 4.95 6.25 - 7.25 15.0 - 17.4 18.8 - 21.8 30.0 - 34.8 55.2 - 64.8
Remote Sensing Possible
Remote ON/OFF Control Possible
Parallel Operation Possible
Series Operation Possible
Monitoring Signal PF (Open collector output)
Line DIP Designed to meet SEMI-F47 (200VAC Line only)
Environment
Operating Temperature (*11) -10 to +70 (-10 to +50: 100, +70: 50)
Storage Temperature -30 to +85
Operating Humidity RH 10 - 90 (No dewdrop)
Storage Humidity RH 10 - 95 (No dewdrop)
Vibration At no operating, 10 - 55Hz (sweep for 1min) 19.6m/s² constant,
X, Y, Z 1hour each.
Shock (In package) Less than 196.1m/
Cooling Forced air by blower fan
Isolation
Withstand Voltage Input - FG : 2.5kVAC (20mA), Input - Output : 3kVAC (20mA)
Output - FG : 500VAC (100mA), Output - CNT : 100VAC (100mA) for 1min
Isolation Resistance More than 100M: Output - FG : 500VDC
More than 10M: Output - CNT: 100VDC at 25 and 70RH
Standards
Safety Standards (*12) Approved by UL60950-1, UL508 (24V model only), CSA C22.2 No.60950-1,
CSA C22.2 No.14-M95 (24V model only), EN60950-1, EN50178,Designed to meet DENAN
PFHC Designed to meet IEC61000-3-2
EMI Designed to meet EN55011/EN55022-B, FCC-B, VCCI-B
Immunity Designed to meet IEC61000-4-2(Level 2,3), -3(Level 3),
-4(Level 3), -5(Level 3,4), -6(Level 3), -8(Level 4), -11
Mechani-
cal
Weight (typ) g 1600
Size (W x H x D) mm 100 x 82 x 165 (Refer to outline drawing)
Pleasereferto"TDK-Lambda
EMCFilters"catalog.
RecommendedEMCFilter
RSEN-2016
HWS 600
#
aHWS5
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
8-M4TAPPEDHOLES
SCREWPENETRATIONDEPTHMAX.6mm
8-M4TAPPEDHOLES
SCREWPENETRATIONDEPTHMAX.6mm
AIRFLOW
NAMEPLATE
==ACCESSORIES==
COVERFORBARRIERTERMINALSTRIP-----1
(ATTACHEDONTERMINALATSHIPMENT)
SHORTPIECE---------------------------------------------1
SHORTING+Vm―+S,-Vm―-S,CNT―TOG
(ATTACHEDONCN1ATSHIPMENT)
26MAX
(37.7)1617.516
7.2
(88.8) 3-M4
10 10 (10)
100±1
(79.5)
4-M5
(14.6)
(14.6)
15
(44.5)
(63.9)
82±1
40±0.560±0.520 21
18MAX
25 120±0.5
110±0.5
5MAX
20
165±1
[unitmm]
PARTDESCRIPTION
SOCKETHOUSING
TERMINALPINS
HANDCRIMPINGTOOL
PARTNAME
PHDR-12VS
SPHD-002T-P0.5(AWG28-24)
SPHD-001T-P0.5(AWG26-22)
YRS-620(SPHD-002T-P0.5)
YC-610R(SPHD-001T-P0.5)
MANUFACT
JST
JST
JST
==MATCHINGHOUSINGS,PINS&TOOL==
PARTNAME
MANUFACT
S12B-PHDSS JST
==SIGNALCONNECTORUSED==
PARTDESCRIPTION
PINHEADER
【HWS600】
0
20
40
60
80
100
120
-100 10203040506070 80
Ta(℃)
LOAD(%)
MOUNTINGA
(STANDARDMOUNTING)
MOUNTINGB DONTUSE DONTUSE
HWS 600
!"
!"
aHWS6
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
(*1) At Ta=25 and maximum output power.
(*2) For cases where conformance to various safety specs (UL, CSA, EN) are required,
input voltage range will be 100 - 240VAC (50/60Hz).
(*3) First in-rush current. Not applicable to the first 0.2ms in-rush current flowing into the power supply noise filter.
(*4) Measure with JEITA RC-9131A probe, bandwidth of scope :100MHz.
At 100uF electric capacitor and 0.47uF film capacitor on the test fixture board.)
(*5) 85 - 265VAC, constant load.
(*6) No load-full load, constant input voltage.
(*7) Constant current limit with automatic recovery. Over current condition for more than 5 seconds will cause the
output to shutdown.
Output current exceeding maximum rated output current for more then 10 seconds continuously will result to
output shutdown.
(*8) OVP circuit will shut down output, manual reset (power cycle) or ON/OFF CNT signal reset.
(*9) At 100/200VAC, nominal output voltage and maximum output current.
(*10) Measured by the each measuring method of UL, CSA, EN and DENAN (at 60Hz), Ta=25 .
(*11) Ratings - Derating at standard mounting.
-Load (%) is percent of maximum output power or maximum output current, whichever is greater.
-As for other mountings, refer to derating curve.
(*12) As for DENAN, built to meet at 100VAC.
(*13) Peak output current is less than 10 seconds, and duty 35% max.(200VAC Line only)
Pleasereferto"TDK-Lambda
EMCFilters"catalog.
RecommendedEMCFilter
RSEN-2020
ITEMS/UNITS LEDOM
HWS1000
-3
HWS1000
-5
HWS1000
-6
HWS1000
-7
HWS1000
-12
HWS1000
-15
HWS1000
-24
HWS1000
-36
HWS1000
-48
HWS1000
-60
,QSXW
&'UR&$9HJQD5HJDWOR9
]+\FQHXTHU)
3RZHU)DFWRU9$&W\S

(IILFLHQF\9$&W\S           
$S\W&$9WQHUUX&
,QUXVK&XUUHQW9$&W\S
$
/HDNDJH&XUUHQW9$&
[DP$P
2XWSXW
1RPLQDO9ROWDJH 9'&      
0D[LPXP&XUUHQW $        
0D[LPXP3HDN&XUUHQW  $     
0D[LPXP3RZHU :      
0D[LPXP3HDN3RZHU  :
0D[LPXP/LQH5HJXODWLRQ  P9      
0D[LPXP/RDG5HJXODWLRQ  P9       
QDKWVVH/WQHLFLIIHR&HUXWDUHSPH7
0D[LPXP
5LSSOH1RLVH
WR°&
P9SS
WR°&
P9SS
VPS\WHPL7SXGOR+
9ROWDJH$GMXVWDEOH5DQJH 9'&

   


  
)XQFWLRQ
2YHU&XUUHQW3URWHFWLRQ  $
! ! ! ! ! ! ! ! !
2YHU9ROWDJH3URWHFWLRQ  9'&

 
  




5HPRWH6HQVLQJ 3RVVLEOH
HOELVVR3ORUWQR&))212HWRPH5
HOELVVR3QRLWDUHS2OHOODUD3
6HULHV2SHUDWLRQ 3RVVLEOH
WXSWXRURWFHOORFQHS2)3ODQJL6JQLU
RWLQR0
\OQRHQLO&$9),0(6WHHPRWWOLX%3,'HQL/
(QYLURQPHQW
2SHUDWLQJ7HPSHUDWXUH  WRVWDUWXSWR
WR℃% 
℃%
℃% 
6WRUDJH7HPSHUDWXUH WR
2SHUDWLQJ+XPLGLW\ JQLVQHGQR&R1+5
6WRUDJH+XPLGLW\ JQLVQHGQR&R1+5
KFDHUXRK=<;WQD
WVQRFðVPQLPURISHHZV]+JQLWDUHSRRQW$QRLWDUEL9
ðVPQDKWVVH/HJDNFDSQ,
NFRK6
&RROLQJ )RUFHGDLUE\EORZHUIDQ
,VRODWLRQ
:LWKVWDQG9ROWDJH ,QSXW)*N9$&P$,QSXW2XWSXWN9$&P$
2XWSXW)*9$&P$9PRGHO9$&P$2XWSXW&179$&P$IRUPLQ
,VRODWLRQ5HVLVWDQFH 0RUHWKDQ0Ω2XWSXW)*9'&
0RUHWKDQ0Ω2XWSXW&179'&DWDQG5+
6WDQGDUGV
6DIHW\6WDQGDUGV  $SSURYHGE\8/&6$&1R(1(1%XLOWWRPHHW'(1$1
3)+& %XLOWWRPHHW,(&
%VVDO&536,&%VVDO&,&&9%VVDO&&&)%1(1(WHHPRWWOLX%,0(
,PPXQLW\ %XLOWWRPHHW,(&/HYHO/HYHO/HYHO
/HYHO/HYHO/HYHO
0HFKDQLFDO
J[DPWKJLH:
JQLZDUGHQLOWXRRWUHIH5[[PP'[+[:H]L6
HWS 1000
$
aHWS7
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
AIR
FLOW
[unitmm]
[Chassismaterial:SPCC-SD]
4−M4
4−M4
220±0.5
1036MAX
25±1
20MAX 4MAX
10 220±0.5
240±1
10±1
2−φ9
(11.2)
23.7±1
25±1
33
(9.1)
(73.6)
11
126.5±1
20
22
10
45.4±1
1111
(56.8)
(15.1)
(23.3) 20
82±1
60±0.5 112±0.5 7.25
11
OUTPUT
TERMINAL
INPUT
TERMINAL
NAMEPLATE NAMEPLATE
I/OSIGNALCONNECTOR
(SEENOTEA)
8-M4TAPPEDHOLES(BOTHSIDES)
SCREWPENETRATIONDEPTHMAX.6mm
8-M4TAPPEDHOLES(BOTHSIDES)
SCREWPENETRATIONDEPTHMAX.6mm
BUSBAR
SPACER
(BLACK)
BUSBAR
SPACER
(RED)
【HWS1000】
85VAC
90VAC〜
85VAC(3,5Vmodel)
90VAC〜(3,5Vmodel)
0
20
40
60
80
100
−10 100 203040506070
71
80
Ta(℃)
LOAD(%)
MOUNTINGA,B,C,D,G,H
ACCESSORIES
*ATTACHEDCONNECTOR
SHORTING+S +V,-S -V,PV REF&CNT TOGATTACHEDON
CN02ATSHIPMENT
*Aseparateconnectornot included isrequiredinordertoutilizethe power
supplyfunction.
NOTES
A:I/OSIGNALCONNECTOR
CONNECTOR : S12B-PHDSS(LF)(SN) (JST)
MATCHINGHOUSING : PHDR-12VS (JST)
MATCHINGCONTACT : SPHD-002T-P0.5(AWG28-24) (JST)OR
SPHD-001T-P0.5(AWG26-22) (JST)OR
BPHD-001T-P0.5(AWG26-22) (JST)
HANDCRIMPINGTOOL : YRS-620(SPHD-002T-P0.5) (JST)
YC-610R(SPHD-001T-P0.5) (JST)
YC-610R(BPHD-001T-P0.5) (JST)
MOUNTINGA
(STANDARDMOUNTING) MOUNTINGB
MOUNTINGG
MOUNTINGC MOUNTINGD
DON'TUSE DON'TUSE
MOUNTINGH
*Itcannotbeusedeventheproductisflippedvertically.
HWS 1000
!"
!"
aHWS8
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
(*1) At Ta=25 and maximum output power.
(*2) For cases where conformance to various safety specs (UL, CSA, EN) are required,input voltage range will be 100 - 240VAC (50/60Hz).
(*3) First in-rush current. Not applicable to the first 0.2ms in-rush current flowing into the power supply noise filter.
(*4) Measure with JEITA RC-9131A probe, bandwidth of scope: 100MHz.
(at 100uF electric capacitor and 0.47uF film capacitor on the test fixture board.)
Ripple noise spec for ambient temperature between -10 to 25 is a linearity value with respect to the -10 degrees
C and 25 degrees C specs.
(*5) 85 - 265VAC, constant load.
(*6) No load-Full load, constant input voltage.
(*7) Constant current limit with automatic recovery. Over current condition for more than 5 seconds will cause the out-
put to shutdown. Output current exceeding maximum rated output current for more then 10 seconds continuously
will result to output shutdown.
(*8) OVP circuit will shut down output, manual reset (power cycle) or ON/OFF CNT signal reset.
(*9) At 100/200VAC, nominal output voltage and maximum output current.
(*10) Measured by the each measuring method of UL, CSA, EN and DENAN (at 60Hz), Ta=25 .
(*11) Ratings - Derating at standard mounting.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- As for other mountings, refer to derating curve.
(*12) As for DENAN, built to meet at 100VAC.
(*13) Peak output current is less than 10 seconds, and duty 35% max. (200VAC Line only)
Pleasereferto"TDK-Lambda
EMCFilters"catalog.
RecommendedEMCFilter
RSEN-2030
ITEMS/UNITS LEDOM
HWS1500
-3
HWS1500
-5
HWS1500
-6
HWS1500
-7
HWS1500
-12
HWS1500
-15
HWS1500
-24
HWS1500
-36
HWS1500
-48
HWS1500
-60
,QSXW
&'UR&$9HJQD5HJDWOR9
]+\FQHXTHU)
3RZHU)DFWRU9$&W\S
(IILFLHQF\9$&W\S         
&XUUHQW9$&W\S  $

,QUXVK&XUUHQW9$&W\S 
$
/HDNDJH&XUUHQW9$& 
[DP$P
2XWSXW
1RPLQDO9ROWDJH 9'&     
0D[LPXP&XUUHQW9$& $ 
   
  

0D[LPXP3HDN&XUUHQW  $     
0D[LPXP3RZHU9$& :  


 
0D[LPXP3HDN3RZHU  :   
0D[LPXP/LQH5HJXODWLRQ  P9      
9PQRLWDOXJH5GDR/PXPL[D0
QDKWVVH/WQHLFLIIHR&HUXWDUHSPH7
0D[LPXP
5LSSOH1RLVH 
WR
P9SS
P9SS

P9SS
VPS\WHPL7SXGOR+
9ROWDJH$GMXVWDEOH5DQJH 9'&

  
     
)XQFWLRQ
2YHU&XUUHQW3URWHFWLRQ  $ ! ! ! ! ! ! ! ! !
2YHU9ROWDJH3URWHFWLRQ  9'&
         
5HPRWH6HQVLQJ 3RVVLEOH
HOELVVR3ORUWQR&))212HWRPH5
3DUDOOHO2SHUDWLRQ 3RVVLEOH
6HULHV2SHUDWLRQ 3RVVLEOH
WXSWXRURWFHOORFQHS2)3ODQJL6JQLURWLQR0
\OQRHQL/&$9
),0(6WHHPRWWOLX%3,'HQL/
(QYLURQPHQW
2SHUDWLQJ7HPSHUDWXUH  WRVWDUWXSWR
DW,QSXW9ROWDJH
9$&9$&
WR&
:




&:




&:




:&




6WRUDJH7HPSHUDWXUH WR
2SHUDWLQJ+XPLGLW\ JQLVQHGQR&R1+5
6WRUDJH+XPLGLW\ JQLVQHGQR&R1+5
KFDHUXRK=<;WQDWVQRFðVPQLP
URISHHZV]+JQLWDUHSRRQW$QRLWDUEL9
ðVPQDKWVVH/HJDNFDSQ,NFRK6
&RROLQJ )RUFHGDLUE\EORZHUIDQ
,VRODWLRQ :LWKVWDQG9ROWDJH ,QSXW)*N9$&P$,QSXW2XWSXWN9$&P$2XWSXW&179$&P$
2XWSXW)*9$&P$9PRGHO9$&P$IRUPLQ
0QDK
WHUR0HFQDWVLVH5QRLWDORV, Ω2XWSXW)*9'&0RUHWKDQ0Ω2XWSXW&179'&DWDQG5+
6WDQGDUGV
6DIHW\6WDQGDUGV  $SSURYHGE\8/&6$&1R(1(1%XLOWWRPHHW'(1$1
3)+& %XLOWWRPHHW,(&
$VVDO&,&&9$VVDO&&&)$1(1(WHHPRWWOLX%,0(
,PPXQLW\
%XLOWWRPHHW,(&/HYHO/HYHO/HYHO/HYHO/HYHO/HYHO
0HFKDQLFDO
JS\WWKJLH:
JQLZDUGHQLOWXRRWUHIH5[[PP'[+[:H]L6
HWS 1500
$%
aHWS9
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
9
82±1
(56.8)
(11.2)
(23.3)
(15.1) 4-M4
OUTPUT
TERMINAL
INPUT
TERMINAL
(9.1)
(73.6)
126.5±1
111111
20 10
3
46MAX
260±0.5
260±0.5
280±1 4MAX
10
20MAX
10
22
3
23.7±125±1
112±0.5
60±0.511 7.25
35±1
4-M4
2 -φ9
45.4±1 20
20±1
8-M4TAPPEDHOLES(BOTHSIDES)
NAMEPLATE NAMEPLATE
I/OSIGNALCONNECTOR
(SEENOTEA)
SCREWPENETRATIONDEPTHMAX.6mm
8-M4TAPPEDHOLES(BOTHSIDES)
SCREWPENETRATIONDEPTHMAX.6mm
BUSBAR
SPACER
(BLACK)
BUSBAR
SPACER
(RED)
AIR
FLOW
[unitmm]
[Chassismaterial:SPCC-SD]
MOUNTINGA
(STANDARDMOUNTING)
MOUNTINGB MOUNTINGC MOUNTINGD DON'TUSE DON'TUSE
【HWS1500】
NOTES
A:I/OSIGNALCONNECTOR
CONNECTOR : S12B-PHDSS(LF)(SN) (JST)
MATCHINGHOUSING : PHDR-12VS (JST)
MATCHINGCONTACT : SPHD-002T-P0.5(AWG28-24) (JST)OR
SPHD-001T-P0.5(AWG26-22) (JST)OR
BPHD-001T-P0.5(AWG26-22) (JST)
HANDCRIMPINGTOOL : YRS-620(SPHD-002T-P0.5) (JST)
YC-610R(SPHD-001T-P0.5) (JST)
YC-610R(BPHD-001T-P0.5) (JST)
0
20
40
60
80
100
120
80 9085 95 100 105 110 115
3V-7
12V-60
LOAD(%)
InputVoltage(VAC)
INPUTVOLTAGEDERATINGCURVE
0
20
40
60
80
100
120
−10 100 20304050607080
6V-60
3V,5
LOAD(%)
Ta(°C)
OUTPUTDERATINGCURVE
MOUNTINGA,B,C,D MOUNTINGA,B,C,D
Allspecificationsaresubjecttochangewithoutnotice.
ACCESSORIES
*ATTACHEDCONNECTOR
SHORTING+S +V,-S -V,PV REF&CNT TOGATTACHEDON
CN01ATSHIPMENT
*Aseparateconnectornot included isrequiredinordertoutilizethe power
supplyfunction.
*Itcannotbeusedeventheproductisflippedvertically.
HWS 1500
!"
!"
aHWS10
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
Pleasereferto"TDK-Lambda
EMCFilters"catalog.
RecommendedEMCFilter
RTEN-5020
$W7D DQGPD[LPXPRXWSXWSRZHU
)RUFDVHVZKHUHFRQIRUPDQFHWRYDULRXVVDIHW\VSHFV8/&6$(1DUHUHTXLUHG
LQSXWYROWDJHUDQJHZLOOEH9$&+]
)LUVWLQUXVKFXUUHQW1RWDSSOLFDEOHWRWKHILUVWPVLQUXVKFXUUHQWIORZLQJLQWRWKHSRZHUVXSSO\QRLVHILOWHU
0HDVXUHZLWK-(,7$5&$SUREHEDQGZLGWKRIVFRSH0+]

$WX)HOHFWULFFDSDFLWRUDQGX)ILOPFDSDFLWRURQWKHWHVWIL[WXUHERDUG
5LSSOHQRLVHVSHFIRUDPELHQWWHPSHUDWXUHEHWZHHQWRLVDOLQHDULW\YDOXHZLWKUHVSHFWWRWKHGHJUHHV
&DQGGHJUHHV&VSHFV
9$&FRQVWDQWORDG
1RORDGIXOOORDGFRQVWDQWLQSXWYROWDJH
&RQVWDQWFXUUHQWOLPLWZLWKDXWRPDWLFUHFRYHU\2YHUFXUUHQWFRQGLWLRQIRUPRUHWKDQVHFRQGVZLOOFDXVHWKH
RXWSXWWRVKXWGRZQ
2XWSXWFXUUHQWH[FHHGLQJPD[LPXPUDWHGRXWSXWFXUUHQWIRUPRUHWKHQVHFRQGVFRQWLQXRXVO\ZLOOUHVXOWWR
RXWSXWVKXWGRZQ
293FLUFXLWZLOOVKXWGRZQRXWSXWPDQXDOUHVHWSRZHUF\FOHRU212))&17VLJQDOUHVHW
$W9$&+]QRPLQDORXWSXWYROWDJHDQGPD[LPXPRXWSXWFXUUHQW
0HDVXUHGE\WKHHDFKPHDVXULQJPHWKRGRI8/&6$DQG(1DW+]7D 
5DWLQJV'HUDWLQJDWVWDQGDUGPRXQWLQJ
 $VIRURWKHUPRXQWLQJVUHIHUWRGHUDWLQJFXUYH
3HDNRXWSXWFXUUHQWLVOHVVWKDQVHFRQGVDQGGXW\PD[
ITEMS/UNITS LEDOM
HWS1800T
-3
HWS1800T
-5
HWS1800T
-6
HWS1800T
-7
HWS1800T
-12
HWS1800T
-15
HWS1800T
-24
HWS1800T
-36
HWS1800T
-48
HWS1800T
-60
,QSXW
9HJQD5HJDWOR9 φ$&
]+\FQHXTHU)
S\W&$9URWFD)UHZR3
(IILFLHQF\9$&W\S 
$S\W&$9WQHUUX&
$S\W&$9WQHUUX&KVXUQ,
/HDNDJH&XUUHQW9$&
$P
PD[
2XWSXW
1RPLQDO9ROWDJH 9'&      
0D[LPXP&XUUHQW $        
0D[LPXP3HDN&XUUHQW  $        
:UHZ
R3PXPL[D0
:UHZR3NDH3PXPL[D0
0D[LPXP/LQH5HJXODWLRQ  P9       
9PQRLWDOXJH5
GDR/PXPL[D0
QDKWVVH/WQHLFLIIHR&HUXWDUHSPH7
0D[LPXP
5LSSOH1RLVH

WR
P9SS
P9SS

P9SS
VPS\WHPL7SXGOR+
9ROWDJH$GMXVWDEOH5DQJH 9'&

   



 
)XQFWLRQ
2YHU&XUUHQW3URWHFWLRQ  $ ! ! ! ! ! ! ! ! !
2YHU9ROWDJH3URWHFWLRQ  9'&

 

 




5HPRWH6HQVLQJ 3RVVLEOH
HOELVVR3ORUWQR&))212HWRPH5
HOELVVR3ORUWQR&ODQUHW[(HJDWOR9WXSWX2
HOELVVR3QRLWDUHS2OHOODUD3
6HULHV2SHUDWLRQ 3RVVLEOH
WXSWXRURWFHOORFQHS2)3ODQJL6JQLURWLQR0
/LQH',3 %XLOWWRPHHW6(0,)
(QYLURQPHQW
2SHUDWLQJ7HPSHUDWXUH

WR6WDUWXSWR
WR:



:

 

:

 

:



6WRUDJH7HPSHUDWXUH WR
2SHUDWLQJ+XPLGLW\ 5+ 1R&RQGHQVLQJ
6WRUDJH+XPLGLW\ +5 1R&RQGHQVLQJ
KFDHUXRK=<;WQDWVQRFðVPQLPURISHHZV]+JQLWDUHSRR
QW$QRLWDUEL9
ðVPQDKWVVH/HJDNFDSQ,NFRK6
&RROLQJ )RUFHGDLUE\EORZHUIDQ
,VRODWLRQ
:LWKVWDQG9ROWDJH ,QSXW)*N9$&P$,QSXW2XWSXWN9$&P$
2XWSXW)*9$&P$9PRGHO9$&P$2XWSXW&179$&P$IRUPLQ
,VRODWLRQ5HVLVWDQFH 0RUHWKDQ0Ω2XWSXW)*9'&
0RUHWKDQ0Ω2XWSXW&179'&DWDQG5+
6WDQGDUGV
1(R1&$6&/8\EGHYRUSS$VGUDGQDW6\WHID6
$VVDO&,&&9$VVDO&&&)$
1(1(WHHPRWWOLX%,0(
,PPXQLW\ %XLOWWRPHHW,(&/HYHO/HYHO/HYHO
/HYHO/HYHO/HYHO
0HFKDQLFDO
JS\WWKJLH:
JQLZDUGHQLOWXRRWUHIH5[[PP'[+[:H]L6
HWS 1800T
$&'
aHWS11
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
【HWS1800T3V】
MOUNTINGA
(STANDARDMOUNTING)
MOUNTINGB MOUNTING MOUNTINGD DON'TUSE DON'TUSE
L1L2L3FG
I/OSIGNALCONNECTOR(SEENOTEA)
BUSBARSPACER
NAMEPLATE
NAMEPLATE
(BLACK)
BUSBARSPACER
(RED)
OUTPUTTERMINAL
INPUTTERMINAL
8-M4TAPPEDHOLES(BOTHSIDES)
SCREWPENETRATIONDEPTHMAX.6mm
[unitmm]
[Chassismaterial:SPCC-SD]
260±0.5
260±0.5
280±1
20MAX 4MAX
10
8-M4TAPPEDHOLES(BOTHSIDES)
4−M4
4−M4
(15.1)
(56.8)
(23.3)
(73.6)111111
(9.1)
(11.2)
25±1 23.7±1
112±0.5 7.25
60±0.5
11
33
126.5±1
20
82±1
46MAX 10
2−φ9
35±1
20±1
45.4±1 20
22
10
SCREWPENETRATIONDEPTHMAX.6mm
【HWS1800T】
1000
40
71
71
−10
Load (W)
Ta(℃)
Ta(℃)
Load (W)
2003010
3010
50
60
0
40
−10 20
05060
0
800
1000
1200
1400
1600
600
400
200
800
600
400
200
MOUNTINGA,B,C,D
MOUNTINGA,B,C,D
−10 7120
050
60
Ta(℃)
Ta(℃)
Load (W)Load (W)
40
0
3010
3010
7140
−10 20
050
60
800
1000
1200
1400
1600
1800
2000
600
400
200
0
800
1000
1200
1400
1600
600
400
200
MOUNTINGA,B,C,D
MOUNTINGA,B,C,D
【HWS1800T6V-15V】
【HWS1800T24V-60V】【HWS1800T5V】
NOTES
A:I/OSIGNALCONNECTOR
CONNECTOR : S12B-PHDSS(LF)(SN) (JST)
MATCHINGHOUSING : PHDR-12VS (JST)
MATCHINGCONTACT : SPHD-002T-P0.5(AWG28-24) (JST)OR
SPHD-001T-P0.5(AWG26-22) (JST)OR
BPHD-001T-P0.5(AWG26-22) (JST)
HANDCRIMPINGTOOL : YRS-620(SPHD-002T-P0.5) (JST)
YC-610R(SPHD-001T-P0.5) (JST)
YC-610R(BPHD-001T-P0.5) (JST)
ACCESSORIES
*ATTACHEDCONNECTOR(3-7V)
SHORTING +S (+),-S (-),PV REF&CNT TOGATTACHED ON
CN01ATSHIPMENT
*ATTACHEDCONNECTOR(12-60V)
SHORTING+S +V,-S -V,PV REF&CNT TOGATTACHEDON
CN01ATSHIPMENT
*Aseparateconnectornot included isrequiredinordertoutilizethe power
supplyfunction.
*Itcannotbeusedeventheproductisflippedvertically.
HWS 1800T
!"
!"
■Features









  󱐯



 
   


HWS/HD
■ProductLineup
SingleOutput300W-1800W
Y
E
A
R
S
warranty
5

  
  

■
ConformitytoRoHSDirective


 




    
    
    
    
    
    


  



 


      
      






 


 



 


   




     


  

 


  

 


    
 





 


■Modelnamingmethod
〔HWS300-1800〕
HWS300−5/HD




 
■Applications





UL60590-1/
CSA C22.2 No.60950-1
EN60950-1/
EN50178


Instruction Manual
HWS HWS HD HWS ME HWS-P
(*1) ( ): Peak output current at 200VAC. Operaing time at peak output is less than 10sec, duty is less than 35%.
(*2) At 100/200VAC, Ta=25°C and maximum output power.
(*3) For cases where conformance to various safety specs (UL, CSA, EN) are required, to be described as 100 - 240VAC
(50/60Hz).
(*4) Not applicable for the in-rush current to noise filter for less than 0.2ms.
(*5) Measure with JEITA RC-9131A probe, bandwidth of scope :100MHz.
(*6) 85 - 265VAC, constant load.
(*7) No load-Full load, constant input voltage.
(*8) 3.3, 5V model: Constant current limit and hiccup with automatic recovery.
12 - 48V model: Constant current limit with automatic recovery.
Avoid to operate at over load or short circuit condition for more than 30 seconds.
(*9) OVP circuit will shut the output down, manual reset (CNT reset or re power on).
(*10) At 100/200VAC, nominal output voltage and maximum output current.
(*11) Measured by the each measuring method of UL, CSA, EN and DENAN (at 60Hz), Ta=25°C.
(*12) Ratings - Derating at standard mounting. Refer to output derating curve.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
(*13) For -40°C to -10°C need 3minutes to stabilize the output voltage.
(*14) Category 4 exposure levels : Truck transportation over U.S. highways, composite two-wheeled trailer.
(*15) As for DENAN, designed to meet at 100VAC.
ITEMS/UNITS MODEL
HWS300-3/HD HWS300-5/HD
HWS300-12/HD HWS300-15/HD
HWS300-24/HD HWS300-48/HD
Input
Voltage Range (*3) V AC85 - 265 or DC120 - 330
Frequency (*3) Hz 47 - 63
Power Factor (100/200VAC)(typ) (*2)
0.99 / 0.95
Efficiency (100/200VAC)(typ) (*2) 74 / 77 79 / 82 80 / 83 82 / 85
Current (100/200VAC)(typ) (*2) A 2.7 / 1.4 3.8 / 1.9 4.1 / 2.1
Inrush Current (100/200VAC)(typ) (*4)
A 20 / 40
Leakage Current (*11) mA Less than 0.75. (0.2 (typ) at 100VAC / 0.44 (typ) at 230VAC)
Output
Nominal Voltage VDC 3.3 5 12 15 24 48
Maximum Current (*1) A 60 27 22 14 (16.5) 7
Maximum Power W 198 300 324 330 336
Maximum Line Regulation (*6) mV 20 48 60 96 192
Maximum Load Regulation (*7) mV 30 72 90 144 288
Temperature Coefficient Less than 0.02% / °C
Maximum Ripple & Noise (0<Ta<70°C)
(*5)
mVp-p
120 150 350
Maximum Ripple & Noise (10<Ta< 0°C) (*5)
mVp-p
180 200 400
Hold-up Time (typ) (*10) ms 20
Voltage Adjustable Range VDC 2.64-3.96 4.0-6.0 9.6-14.4 12.0-18.0 19.2-28.8 38.4-52.8
Function
Over Current Protection (*8) A >63 >63 >28.4 >23.1 >16.7 >7.4
Over Voltage Protection (*9) VDC 4.13-4.95 6.25-7.25 15.0-17.4 18.8-21.8 30.0-34.8 55.2-64.8
Remote Sensing Possible
Remote ON/OFF Control Possible
Parallel Operation Possible
Series Operation Possible
Monitoring Signal PF (Open collector output)
Line DIP Designed to meet SEMI-F47 (200VAC Line only)
Environment
Operating Temperature (*12)(*13) °C -10 to +71 (-10 to +50: 100%, +71: 50%)
Guarantee Start up at -40 to -10
Storage Temperature °C -40 to +85
Operating Humidity RH 10 - 90 (No dewdrop)
Storage Humidity RH 10 - 95 (No dewdrop)
Vibration (*14)
At no operating, 10 - 55Hz (sweep for 1min)
19.6m/s² constant, X, Y, Z 1hour each.
Designed to meet MIL-STD-810F 514.5 Category 4,10
Shock (In package) Less than 196.1m/
Designed to meet MIL-STD-810F 516.5 Procedure I, VI
Cooling Forced air by blower fan
Isolation
Withstand Voltage Input - FG : 2.5kVAC (20mA), Input - Output : 3kVAC (20mA)
Output - FG: 500VAC (100mA), Output-CNT: 100VAC(100mA) for 1min
Isolation Resistance More than 100M: Output - FG : 500VDC
More than 10M: Output -CNT : 100VDC at 25°C and 70%RH
Standards
Safety Standards (*15) Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950-1, EN50178
Designed to meet DENAN
PFHC Designed to meet IEC61000-3-2
EMI Designed to meet EN55011/EN55022-B, FCC-B, VCCI-B
Immunity Designed to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3),
-5(Level 3,4), -6(Level 3), -8(Level 4), -11
Mechanical
Weight (typ) g 1000
Size (W x H x D) mm 61 x 82 x 165 (Refer to outline drawing)
Pleasereferto"TDK-Lambda
EMCFilters"catalog.
RecommendedEMCFilter

+:6+'6SHFLILFDWLRQV5HDGLQVWUXFWLRQPDQXDOFDUHIXOO\EHIRUHXVLQJWKHSRZHUVXSSO\XQLW
HWS300/HD


Instruction Manual
HWS HWS HD HWS ME HWS-P
【HWS300/HD】
[unitmm]
AIRFLOW
105±0.5
120±0.525
22MAX
18MAX
5MAX
165±1
25
61±1
3-M4
4-M4
(14.6)
(46.9)
82±1
60±0.5
40±0.510.5 11
(66.6)
(34.5) 11 1114
(47)
(9.5)
10 10
15
7.2
(10.7)
(8.9)
7.3 NAMEPLATE
SCREWPENETRATIONDEPTHMAX.6mm
8-M4TAPPEDHOLES
(TAPPEDATTHEBOTTOMCHASSIS
FAN
8-M4TAPPEDHOLES
== NOTES ==
A : MODEL NAME, NOMINAL OUTPUT VOLT-
AGE AND MAXIMUM OUTPUT CURRENT
ARE SHOWN IN THE NAME PLATE IN
ACCORDANCE WITH THE SPECIFICA-
TIONS.
B : M4 TAPPED HOLES (8) FOR CUSTOMER
CHASSIS MOUNTING.(SCREW
PENETRATION DEPTH 6m/m MAX.)
YRS-620(SPHD-002T-P0.5)
YC-610R(SPHD-001T-P0.5)
(ATTACHED ON CN1 AT SHIPMENT)
---------------------1
== SIGNAL CONNECTOR USED ==
== MATCHING HOUSINGS , PINS & TOOL ==
SPHD-002T-P0.5(AWG28~24)
SPHD-001T-P0.5(AWG26~22)
* COVER FOR BARRIER TERMINAL STRIP ------1
(ATTACHED ON TERMINAL AT SHIPMENT)
SHORTING +Vm +S, -Vm -S, CNT TOG
HAND CRIMPING TOOL
TERMINAL PINS
SOCKET HOUSING
PART DESCRIPTION
PART DESCRIPTION
PIN HEADER
* SHORT PIECE
PHDR-12VS
PART NAME
PART NAME
S12B-PHDSS
== ACCESSORIES ==
JST
JST
JST
MANUFACT
0
20
40
60
80
100
120
10 0 10203040506070
71 80
Ta(°C)
LOAD(%)


  
Ta(°C) LOAD(%)
10to+50
71
100
50
MOUNTINGA MOUNTINGB
HWS300/HD
2XWSXW'HUDWLQJ
2XWOLQH'UDZLQJ


Instruction Manual
HWS HWS HD HWS ME HWS-P
(*1) ( ): Peak output current at 200VAC. Operating time at peak output is less than 10sec, duty is less than 35%.
(*2) At 100/200VAC, Ta=25°C and maximum output power.
(*3) For cases where conformance to various safety specs (UL, CSA, EN) are required,
to be described as 100 - 240VAC (50/60Hz).
(*4) Not applicable for the in-rush current to noise filter for less than 0.2ms.
Inrush Current is 30A (typ) when PFHC start-up.
(*5) Measure with JEITA RC-9131A probe, bandwidth of scope : 100MHz.
(*6) 85 - 265VAC, constant load.
(*7) No load - Full load, constant input voltage.
(*8) 3V and 5V model: Constant current limit and hiccup with automatic recovery.
12 - 48V model: Constant current limitwith automatic recovery.
Avoid to operate at over load or short circuit condition for more than 30 seconds.
(*9) OVP circuit will shut the output down, manual reset (CNT reset or Re-power on).
(*10) At 100/200VAC, nominal output voltage and maximum output current.
(*11) Measured by the each measuring method of UL, CSA, EN and DENAN (at 60Hz), Ta=25°C.
(*12) Ratings - Derating at standard mounting. Refer to output derating curve.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
(*13) For -40°C to -10°C need 3 minutes to stabilize the output voltage.
(*14) Category 4 exposure levels : Truck transportation over U.S. highways, composite two-wheeled trailer.
(*15) As for DENAN, designed to meet at 100VAC.
Pleasereferto"TDK-Lambda
EMCFilters"catalog.
RecommendedEMCFilter

ITEMS/UNITS MODEL
HWS600-3/HD
HWS600-5/HD
HWS600-12/HD HWS600-15/HD
HWS600-24/HD HWS600-48/HD
Input
Voltage Range (*3) V AC85 - 265 or DC120 - 330
Frequency (*3) Hz 47 - 63
Power Factor (100/200VAC)(typ) (*2)
0.99 / 0.95
Efficiency (100/200VAC)(typ) (*2) 75 / 78 80 / 83 81 / 84 82 / 85 83 / 86
Current (100/200VAC)(typ) (*2) A 5.4 / 2.6 7.5 / 3.6 8.1 / 3.9
Inrush Current (100/200VAC)(typ) (*4)
A 20 / 40
Leakage Current (*11) mA Less than 0.75. (0.2 (typ) at 100VAC / 0.44 (typ) at 230VAC)
Output
Nominal Voltage VDC 3.3 5 12 15 24 48
Maximum Current (*1) A 120 53 43 27 (31) 13
Maximum Power W 396 600 636 645 648 624
Maximum Line Regulation (*6) mV 20 48 60 96 192
Maximum Load Regulation (*7) mV 30 72 90 144 288
Temperature Coefficient Less than 0.02% / °C
Maximum Ripple & Noise (0<Ta<70°C)
(*5)
mVp-p
120 150 350
Maximum Ripple & Noise (10<Ta< 0°C) (*5)
mVp-p
180 200 400
Hold-up Time (typ) (*10) ms 20
Voltage Adjustable Range VDC 2.64-3.96 4.0-6.0 9.6-14.4 12.0-18.0 19.2-28.8 38.4-52.8
Function
Over Current Protection (*8) A >126 >55.7 >45.2 >31.4 >13.7
Over Voltage Protection (*9) VDC 4.13-4.95 6.25-7.25 15.0-17.4 18.8-21.8 30.0-34.8 55.2-64.8
Remote Sensing Possible
Remote ON/OFF Control Possible
Parallel Operation Possible
Series Operation Possible
Monitoring Signal PF (Open Collector Output)
Line DIP Designed to meet SEMI-F47 (200VAC Line only)
Environment
Operating Temperature (*12)(*13) °C -10 to +71 (-10 to +50: 100%, +71: 50%) Guarantee start up at -40 to -10
Storage Temperature °C -40 to +85
Operating Humidity RH 10 - 90%RH (No dewdrop)
Storage Humidity RH 10 - 95%RH (No dewdrop)
Vibration (*14) At no operating, 10 - 55Hz (sweep for 1min) 19.6m/s² constant, X, Y, Z 1hour each.
Designed to meet MIL-STD-810F 514.5 Category 4, 10
Shock (In package) Less than 196.1m/s² Designed to meet MIL-STD-810F 516.5 Procedure I, VI
Cooling Forced air by blower fan
Isolation
Withstand Voltage Input - FG : 2.5kVAC (20mA), Input - Output : 3kVAC (20mA)
Output - FG : 500VAC (100mA),Output - CNT : 100VAC(100mA) for 1min
Isolation Resistance More than 100M: Output - FG : 500VDC
More than 10M: Output - CNT : 100VDC at 25°C and 70%RH
Standards
Safety Standards (*15) Approved by UL60950-1, CSA C22.2 No 60950-1, EN60950-1, EN50178
Designed to meet DENAN
PFHC Designed to meet IEC61000-3-2
EMI Designed to meet EN55011/EN55022-B, FCC-B, VCCI-B
Immunity Designed to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3),
-5(Level 3,4), -6(Level 3), -8(Level 4), -11
Mechanical
Weight (typ) g 1600
Size (W x H x D) mm 100 x 82 x 165 (Refer to outline drawing)
HWS600/HD
+:6+'6SHFLILFDWLRQV5HDGLQVWUXFWLRQPDQXDOFDUHIXOO\EHIRUHXVLQJWKHSRZHUVXSSO\XQLW


Instruction Manual
HWS HWS HD HWS ME HWS-P
8-M4TAPPEDHOLES
SCREWPENETRATIONDEPTHMAX.6mm
8-M4TAPPEDHOLES
SCREWPENETRATIONDEPTHMAX.6mm
AIRFLOW
== ACCESSORIES ==
* COVER FOR BARRIER TERMINAL STRIP -----1
(ATTACHED ON TERMINAL AT SHIPMENT)
* SHORT PIECE --------------------1
SHORTING +Vm -+S, -Vm - -S, CNT TOG
(ATTACHED ON CN1 AT SHIPMENT)
== SIGNAL CONNECTOR USED ==
PART DESCRIPTION PART NAME MANUFACT
PIN HEADER S12B-PHDSS JST
== MATCHING HOUSINGS, PINS & TOOL ==
PART DESCRIPTION PART NAME MANUFACT
SOCKET HOUSING PHDR-12VS JST
TERMINAL PINS
SPHD-002T-P0.5(AWG2824)
SPHD-001T-P0.5(AWG2622)
JST
HAND CRIMPING TOOL
YRS-620(SPHD-002T-P0.5)
YC-610R(SPHD-001T-P0.5)
JST
26MAX
(37.7) NAMEPLATE
1617.516
7.2
(88.8) 3-M4
10 10 (10)
100±1
(79.5)
4-M5
(14.6)
(14.6)
15
(44.5)
(63.9)
82±1
40±0.560±0.520 21
18MAX
25 120±0.5
110±0.5
5MAX
20
165±1
[unitmm]
【HWS600/HD】
120
100
80
60
40
20
0
-100 10203040506070
71 80
Ta(℃)
LOAD(%)
Ta(℃) MOUNTINGA
LOAD(%)
10to50
71
100
50
MOUNTINGB
MOUNTINGA
(STANDARDMOUNTING)
MOUNTINGB
DONTUSE
HWS600/HD
2XWSXW'HUDWLQJ
2XWOLQH'UDZLQJ


Instruction Manual
HWS HWS HD HWS ME HWS-P
Pleasereferto"TDK-Lambda
EMCFilters"catalog.
RecommendedEMCFilter

ITEMS/UNITSMODEL
HWS1000
-3/HD
HWS1000
-5/HD
HWS1000
-6/HD
HWS1000
-7/HD
HWS1000
-12/HD
HWS1000
-15/HD
HWS1000
-24/HD
HWS1000
-36/HD
HWS1000
-48/HD
HWS1000
-60/HD

 

           




        
         
 
     
      
 
      
      

 




 

   
    

 
        
        
   
 
 

  



 
 
 
  

  
 




 


  
 























󰴸

HWS1000/HD
+:6+'6SHFLILFDWLRQV
5HDGLQVWUXFWLRQPDQXDOFDUHIXOO\EHIRUHXVLQJWKHSRZHUVXSSO\XQLW
PleaserefertopageaHWS24forMIL-STDMounting


Instruction Manual
HWS HWS HD HWS ME HWS-P
【HWS1000/HD】





 
 



 
  




 


=NOTES=
1) Input voltage: Not gradual start up.
2) No Condensing.






    





HWS1000/HD
2XWSXW'HUDWLQJ
2XWOLQH'UDZLQJ










 
 

















 

  





 














  
  
  
 
 
  
 
  








6WDUWXSFRQGLWLRQDWORZWHPSHUDWXUH


Instruction Manual
HWS HWS HD HWS ME HWS-P
ITEMS/UNITS MODEL
HWS1500
-3/HD
HWS1500
-5/HD
HWS1500
-6/HD
HWS1500
-7/HD
HWS1500
-12/HD
HWS1500
-15/HD
HWS1500
-24/HD
HWS1500
-36/HD
HWS1500
-48/HD
HWS1500
-60/HD
Input
Voltage Range (*2) V AC85 - 265
Frequency (*2) Hz 47 - 63
Power Factor (100/230VAC)(typ) (*1)
0.98 / 0.94
Efficiency (100/200VAC)(typ) (*1) 72 / 75 77 / 81 79 / 82 81 / 83 82 / 85 83 / 87 84 / 88 86 / 90
Current (100/200VAC)(typ) (*1) A 15.0 / 8.0 19.5 / 10.0 19.0 / 10.0
Inrush Current (100/200VAC)(typ) (*3)
A 20 / 40
Leakage Current (100/240VAC) (*10)
mA 1.5 max
Output
Nominal Voltage V 3.3 5 6 7.5 12 15 24 36 48 60
Maximum Current (100/200VAC) A 300 / 300
250 / 250 200 / 200
125 / 125 100 / 100 65 / 70 42 / 46.5 32 / 32 25.6 / 28
Maximum Peak Current (*13) A 300 240 105 70 42
Maximum Power (100VAC/200VAC)
W 990/990 1500/1500
1560 /1680 1512/1674 1536 /1536 1536 /1680
Maximum Peak Power (*13) W 1800 2520 2520
Maximum Line Regulation (*5) mV 36 40 48 60 96 144 192 240
Maximum Load Regulation (*6) mV 60 72 90 144 150 288 360
Temperature Coefficient Less than 0.02%/°C
Maximum
Ripple & Noise (*4)
+25 to +71°C
mVp-p
150 200 400
0°C
mVp-p
200 150 200 400
-10°C
mVp-p
220 200 240 400 600
Hold-up Time (typ) (*9) ms 20 16 20
Voltage Adjustable Range VDC
2.64 - 3.96
4.0 - 6.0 4.8 - 7.2 6.0 - 9.0 9.6 - 14.4
12.0 - 18.0 19.2 - 28.8 28.8 - 43.2 38.4 - 52.8 48.0 -66.0
Function
Over Current Protection (*7) A > 315.0 > 262.5 > 210.0 > 131.2 > 105.0 > 68.2 > 44.1 > 33.6 > 26.8
Over Voltage Protection (*8) VDC
4.12 - 4.62
6.25 - 7.0 7.5 - 8.4
9.37 - 10.5 15.0 - 17.4 18.7 - 21.8 30.0 - 34.8 45.0 - 49.7 55.2 - 64.8 69.0 - 75.0
Remote Sensing Possible
Remote ON/OFF Control Possible
Parallel Operation Possible
Series Operation Possible
Monitoring Signal PF (Open collector output)
Line DIP Designed to meet SEMI-F47 (200VAC Line only)
Other Function PCB Coating on solder side and component side.
Environment
Operating Temperature (*11) °C -10 to +71, Guarantee start up at -40 to -10
at Input Voltage
100VAC/200VAC
-10 to +40C
W990 1500
1560 / 1680
1512 / 1674
1536
1536 / 1680
+50C W 825 1250 1500
1560 / 1680
1512 / 1674
1536
1536 / 1680
+60C W 660 1000 1125
1170 / 1260
1134 / 1255
1152
1152 / 1260
+71C W 495 750
780 / 840
756 / 837
768
768 / 840
Storage Temperature °C -40 to +85
Operating Humidity RH 10 - 90 (No Condensing)
Storage Humidity RH 10 - 95 (No Condensing)
Vibration (*14)(*15) At no operating, 10 - 55Hz (sweep for 1min.) 19.6m/s² constant, X,Y,Z 1hour each.
Designed to meet MIL-STD-810F 514.5 Category 4 figure 514.5C-1 and Category 10
Shock (In package) (*15) Less than 196.1m/s2 Designed to meet MIL-STD-810F 516.5 Procedure I
Cooling Forced air by blower fan
Isolation
Withstand Voltage Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA), Output - CNT : 100VAC (100mA)
Output - FG : 500VAC (300mA), (60V model 651VAC (390mA) ) for 1min.
Isolation Resistance More than 100M: Output - FG : 500VDC
More than 10M: Output - CNT : 100VDC at 25°C and 70%RH
Standards
Safety Standards (*12) Approved by UL60950-1, CSA C22.2 No.,60950-1, EN60950-1, EN50178. Designed to meet DENAN.
PFHC Designed to meet IEC61000-3-2
EMI Designed to meet EN55011/EN55022-A, FCC-ClassA, VCCI-ClassA.
Immunity Designed to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3),
-5(Level 3,4), -6(Level 3), -8(Level 4), -11
Mechanical
Weight (typ) g 4000 3800
Size (W x H x D) mm 126.5 x 82 x 280 (Refer to outline drawing)
(*1) At Ta=25°C and maximum output power.
(*2) For cases where conformance to various safety specs (UL, CSA, EN) are required, input voltage range will be 100 - 240VAC (50/60Hz).
(*3) First in-rush current. Not applicable to the first 0.2ms in-rush current flowing into the power supply noise filter.
(*4) Measure with JEITA RC-9131A probe, bandwidth of scope :100MHz. at 100uF electric capacitor and 0.47uF film capacitor on the test fixture board.)
Ripple noise spec for ambient temperature between -10 to 25 is a linearity value with respect to the -10 degrees C and 25 degrees C specs.
(*5) 85 - 265VAC , constant load.
(*6) No load-full load, constant input voltage.
(*7) Constant current limit with automatic recovery. Over current condition for more than 5 seconds will cause the out-
put to shutdown. Output current exceeding maximum rated output current for more than 10 seconds continuously will result
to output shutdown.
(*8) OVP circuit will shut down output, manual reset (power cycle) or ON/OFF CNT signal reset.
(*9) At 100/200VAC, nominal output voltage and maximum output current.
(*10) Measured by the each measuring method of UL, CSA, EN and DENAN (at 60Hz), Ta=25°C.
(*11) Ratings - Derating at standard mounting.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- As for other mountings, refer to derating curve.
- For conditions of start up at -40°C to -10°C, refer to derating curve.
(*12) As for DENAN, designed to meet at 100VAC.
(*13) Peak output current is less than 10 seconds, and duty 35% max.(200VAC Line only)
(*14) Category 4 exposure levels : Track transportation over U.S. highways.
(*15) It is compulsory to fix BRACKET onto product for MIL-STD-810F 516.5 Procedure 󰴸
and MIL-STD-810F 514.5 category 10 compliance. Refer to mounting method.
Pleasereferto"TDK-Lambda
EMCFilters"catalog.
RecommendedEMCFilter

PleaserefertopageaHWS24forMIL-STDMounting
+:6+'6SHFLILFDWLRQV
5HDGLQVWUXFWLRQPDQXDOFDUHIXOO\EHIRUHXVLQJWKHSRZHUVXSSO\XQLW
HWS1500/HD


Instruction Manual
HWS HWS HD HWS ME HWS-P
120
100
80
60
40
20
0
-50 -40 -30 -20 -10
LOAD(%)
Ta(℃)
85V
90V〜
82±1
(56.8)
(11.2)
(23.3)
(15.1) 4-M4
OUTPUTTERMINAL
INPUTTERMINAL
(9.1)
(73.6)
126.5±1
111111
20 10
3
46MAX
260±0.5
260±0.5
280±1 4MAX
10
20MAX
10
22 3
23.7±125±1
112±0.5
60±0.511
7.25
35±1
4-M4
2-φ9
45.4±1 20
20±1
8-M4TAPPEDHOLES(BOTHSIDES)
SCREWPENETRATIONDEPTHMAX.6mm
8-M4TAPPEDHOLES(BOTHSIDES)
I/OSIGNALCONNECTOR
(SEENOTEA)
SCREWPENETRATIONDEPTHMAX.6mm
BUSBARSPACER
(BLACK)
NAMEPLATE NAMEPLATE
BUSBARSPACER
(RED)
AIR
FLOW
ACCESSORIES
* ATTACHED CONNECTOR (3~7V)
SHORTING +S〜(+), -S〜(-), PVREF & CNTTOG
ATTACHED ON CN01 AT SHIPMENT
* ATTACHED CONNECTOR (12_60V)
SHORTING +S~+V, -S~-V, PV~REF & CNT~TOG
ATTACHED ON CN01 AT SHIPMENT
* A separate connector not included is required in order to utilize the power supply function.
NOTES
A: I/O SIGNAL CONNECTOR
CONNECTOR : S12B-PHDSS(LF)(SN) (JST)
MATCHING HOUSING : PHDR-12VS (JST)
MATCHING CONTACT : SPHD-002T-P0.5(AWG2824) (JST) OR
SPHD-001T-P0.5(AWG2622) (JST) OR
BPHD-001T-P0.5(AWG2622) (JST)
HAND CRIMPING TOOL : YRS-620(SPHD-002T-P0.5) (JST)
YC-610R(SPHD-001T-P0.5) (JST)
YC-610R(BPHD-001T-P0.5) (JST)
[unitmm]
[Chassismaterial:SPCC-SD]
【HWS1500/HD】
=NOTES=
1) Input voltage: Not gradual start up.
2) No condensing.
3) Output voltage becomes more stable by performing the following.
a) Electrolytic capacitor is added to an output.
+3.3V, +5V, +6V : LXZ 10V 5600uF (NIPPON CHEMI-CON) x 3 parallel
+7.5V : LXZ 16V 3900uF (NIPPON CHEMI-CON) x 3 parallel
+12V : LXZ 25V 2700uF (NIPPON CHEMI-CON) x3 parallel
+15V : LXZ 25V 2700uF (NIPPON CHEMI-CON) x3 parallel
+24V : LXZ 35V 1800uF (NIPPON CHEMI-CON) x3 parallel
+36V : LXZ 50V 1000uF (NIPPON CHEMI-CON) x3 parallel
+48V : LXZ 63V 820uF (NIPPON CHEMI-CON) x3 parallel
+60V : LXV 100V 270uF (NIPPON CHEMI-CON) x 3 parallel
b) Remote sensing function is used.
Connect "+S" terminal to "+" terminal of the electrolytic capacitor
and "-S" terminal to "-" terminal of the electrolytic capacitor with sensing wires.
4) Pay attention to above items before using the unit. Incorrect usage could lead to unstable
output voltage.
100
80
60
40
20
0
-100 10203040506070
71 80
Ta(℃
LOAD(%)
85V
90V〜
MOUNTINGA
T
ANDARDMOUNTING)
MOUNTINGD DON'TUSE DON'TUSE
MOUNTINGB MOUNTINGC
*Itcannotbeusedeventheproduct
isflippedvertically.

2XWSXW'HUDWLQJ
2XWOLQH'UDZLQJ
HWS1500/HD
6WDUWXSFRQGLWLRQDWORZWHPSHUDWXUH


Instruction Manual
HWS HWS HD HWS ME HWS-P
Pleasereferto"TDK-Lambda
EMCFilters"catalog.
RecommendedEMCFilter

ITEMS/UNITS LEDOM
HWS1800T
-3/HD
HWS1800T
-5/HD
HWS1800T
-6/HD
HWS1800T
-7/HD
HWS1800T
-12 /HD
HWS1800T
-15 /HD
HWS1800T
-24/HD
HWS1800T
-36/HD
HWS1800T
-48/HD
HWS1800T
-60/HD


 


      
         
       








 

   
    

          
        
   
 
 
 

  




 


  

  
 

 

 

























󰴸

PleaserefertopageaHWS24forMIL-STDMounting
+:67+'6SHFLILFDWLRQV
5HDGLQVWUXFWLRQPDQXDOFDUHIXOO\EHIRUHXVLQJWKHSRZHUVXSSO\XQLW
HWS1800T/HD


Instruction Manual
HWS HWS HD HWS ME HWS-P
【HWS1800T/HD】
2000
1800
1600
1400
1200
1000
800
600
400
200
0-100 10203040506070
71 80
3V
5V
6V〜15
24V〜60
Ta(℃)
LOAD(W)
=NOTES=
1) Input voltage: Not gradual start up.
2) No Condensing.
3) Output voltage becomes more stable by performing the following.
a) Electrolytic capacitor is added to an output.
+3.3V,+5V,+6V : LXZ 10V 5600uF (NIPPON CHEMI-CON) x 3 parallel
+7.5V : LXZ 16V 3900uF (NIPPON CHEMI-CON) x 3 parallel
+12V : LXZ 25V 2700uF (NIPPON CHEMI-CON) x3 parallel
+15V : LXZ 25V 2700uF (NIPPON CHEMI-CON) x3 parallel
+24V : LXZ 35V 1800uF (NIPPON CHEMI-CON) x3 parallel
+36V : LXZ 50V 1000uF (NIPPON CHEMI-CON) x3 parallel
+48V : LXZ 63V 820uF (NIPPON CHEMI-CON) x3 parallel
+60V : LXV 100V 270uF (NIPPON CHEMI-CON) x 3 parallel
b) Remote sensing function is used.
Connect "+S" terminal to "+" terminal of the electrolytic capacitor
and "-S" terminal to "-" terminal of the electrolytic capacitor with sensing wires.
4) Pay attention to above items before using the unit. Incorrect usage could lead to un-
stable output voltage.
120
100
80
60
40
20
0
-50 -40 -30 -20 -10
Ta(℃)
LOAD(%)
6WDUWXSFRQGLWLRQDWORZWHPSHUDWXUH
Ta
(℃
MOUNTINGA
(STANDARDMOUNTING)
DON'TUSE DON'TUSE
MOUNTINGB MOUNTINGC
MOUNTINGD
*Itcannotbeusedeventheproduct
isflippedvertically.

HWS1800T/HD
2XWSXW'HUDWLQJ
2XWOLQH'UDZLQJ






 


  
 




󱼹




 
 
 














 

/
)* / /


   
   
  
 
 
  
 
 












Instruction Manual
HWS HWS HD HWS ME HWS-P
SpecificationReference
 












 

 

󱼹
󱼹








󱼹

 
HWS1000/HD, 1500/HD, 1800T/HD
32:(56833/<02817,1*)250,/67'


Instruction Manual
HWS HWS HD HWS ME HWS-P


Instruction Manual
HWS HWS HD HWS ME HWS-P
■Features






  󱐯



 
   


■ProductLineup
SingleOutput300W-1500W
■Applications
HWS/ME
UL60601-1/
CSA C22.2 No.601.1-M90
EN60601-1
■Modelnamingmethod
〔HWS300-1500〕
HWS300−5/ME









   



 

 


 
  
    
    


  









    

  




  
  

■
ConformitytoRoHSDirective
Y
E
A
R
S
warranty
5



Instruction Manual
HWS HWS HD HWS ME HWS-P
ITEMS/UNITS MODEL HWS300-12/ME HWS300-15/ME HWS300-24/ME HWS300-48/ME
Input
Voltage Range (*3) V AC85 - 265 or DC120 - 330
Frequency (*3) Hz 47 - 63
Power Factor (100/200VAC)(typ) (*2)
0.99 / 0.95
Efficiency (100/200VAC)(typ) (*2) 80 / 83 82 / 85
Current (100/200VAC)(typ) (*2) A 4.1 / 2.1
Inrush Current (100/200VAC)(typ) (*4)
A 20 / 40
Leakage Current (*11) mA Less than 0.5. (0.15 (typ) at 100VAC / 0.39 (typ) at 230VAC)
Output
Nominal Voltage VDC 12 15 24 48
Maximum Current (*1) A 27 22 14 (16.5) 7
Maximum Power W 324 330 336
Maximum Line Regulation (*6) mV 48 60 96 192
Maximum Load Regulation (*7) mV 72 90 144 288
Temperature Coefficient Less than 0.02% /
Maximum Ripple & Noise (0
<
Ta
<
70 ) (*5)
mVp-p
150 350
Maximum Ripple & Noise (10
<
Ta< 0 ) (*5 )
mVp-p
200 400
Hold-up Time (typ) (*10) ms 20
Voltage Adjustable Range VDC 9.6 - 14.4 12.0 - 18.0 19.2 - 28.8 38.4 - 52.8
Function
Over Current Protection (*8) A >28.4 >23.1 >16.7 >7.4
Over Voltage Protection (*9) VDC 15.0 - 17.4 18.8 - 21.8 30.0 - 34.8 55.2 - 64.8
Remote Sensing Possible
Remote ON/OFF Control Possible
Parallel Operation Possible
Series Operation Possible
Monitoring Signal PF (Open collector output)
Line DIP Designed to meet SEMI-F47 (200VAC Line only)
Environment
Operating Temperature (*12) -10 to +70 (-10 to +50: 100%, +70: 50%)
Storage Temperature -30 to +85
Operating Humidity RH 10 to 90 (No dewdrop)
Storage Humidity RH 10 to 95 (No dewdrop)
Vibration At no operating, 10 - 55Hz (sweep for 1min)
19.6m/s² constant, X, Y, Z 1hour each.
Shock (In package) Less than 196.1m/
Cooling Forced air by blower fan
Isolation
Withstand Voltage Input - FG : 2.5kVAC (20mA), Input - Output : 3kVAC (20mA)
Output - FG: 500VAC (100mA), Output-CNT: 100VAC(100mA) for 1min
Isolation Resistance More than 100M: Output - FG : 500VDC
More than 10M: Output -CNT : 100VDC at 25 and 70%RH
Standards
Safety Standards (*13) Approved by UL60601-1, EN60601-1, CSA-C22.2 No601.1-M90
PFHC Designed to meet IEC61000-3-2
Voltage Fluctuations / Flicker Emissions
Designed to meet IEC61000-3-3
EMI Designed to meet EN55011/EN55022-B, FCC-B, VCCI-B
Immunity Designed to meet IEC61000-4-2(Level 3), -3(Level 3), -4(Level 3),
-5(Level 3,4), -6(Level 3), -8(Level 4), -11
Mechani-
cal
Weight (typ) g 1000
Size (W x H x D) mm 61 x 82 x 165 (Refer to outline drawing)
(*1) ( ):Peak output current at 200VAC. Operating time at peak output is less than 10 sec, duty is less than 35%.
(*2) At 100/200VAC, Ta=25 and maximum output power.
(*3) For cases where conformance to various safety specs (UL, EN, CSA) are required, to be described as 100 - 240VAC (50/60Hz).
(*4) Not applicable for the inrush current to noise filter for less than 0.2ms.
(*5) Measure with JEITA RC-9131A probe, bandwidth of scope: 100MHz.
(*6) 85 - 265VAC, constant load.
(*7) No load-full load, constant input voltage.
(*8) Constant current limit with automatic recovery.
Avoid to operate at over load or short circuit condition for more than 30 seconds.
(*9) OVP circuit will shut the output down, manual reset (CNT reset or re power on).
(*10) At 100/200VAC, nominal output voltage and maximum output current.
(*11) Measured by the each measuring method of UL, EN, and CSA (at 60Hz), Ta=25 .
When using it as a patient care equipment, all outer surfaces of the equipment shall be constructed of
nonconductive material. See clause 19.5DV.2 of UL60601-1.
(*12) Ratings - Derating at standard mounting. Refer to output derating curve.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
(*13) As for UL60601-1, EN60601-1 and CSA-C22.2No601.1-M90, basic insulation.
Pleasereferto"TDK-Lambda
EMCFilters"catalog.
RecommendedEMCFilter

HWS300/ME
+:60(6SHFLILFDWLRQV5HDGLQVWUXFWLRQPDQXDOFDUHIXOO\EHIRUHXVLQJWKHSRZHUVXSSO\XQLW


Instruction Manual
HWS HWS HD HWS ME HWS-P
【HWS300/ME】
NAMEPLATE
AIRFLOW
FAN
105±0.5
120±0.525
22MAX
18MAX
5MAX
165±1
25
61±1
3-M4
4-M4
(14.6)
(46.9)
82±1
60±0.5
40±0.510.5 11
(66.6)
(34.5) 11 1114
(47)
(9.5)
10 10
15
7.2
(10.7)
(8.9)
7.3
8-M4TAPPEDHOLES(TAPPEDATTHEBOTTOMCHASSIS)
SCREWPENETRATIONDEPTHMAX.6mm
8-M4TAPPEDHOLES
SCREWPENETRATIONDEPTHMAX.6mm
==SIGNALCONNECTORUSED==
==MATCHINGHOUSINGS,PINS&TOOL==
==ACCESSORIES==
COVERFORBARRIERTERMINALSTRIP------1
(ATTACHEDONTERMINALATSHIPMENT)
SHORTPIECE---------------------1
SHORTING+Vm―+S,-Vm―-S,CNT―TOG
(ATTACHEDONCN1ATSHIPMENT)
SOCKETHOUSING
TERMINALPINS
HANDCRIMPINGTOOL
PHDR-12VS
SPHD-002T-P0.5(AWG28〜24)
SPHD-001T-P0.5(AWG26〜22)
YRS-620(SPHD-002T-P0.5)
YC-610R(SPHD-001T-P0.5)
JST
JST
JST
PARTDESCRIPTION PARTNAME
MANUFACT
PINHEADER S12B-PHDSS
JST
PARTDESCRIPTION PARTNAME
MANUFACT
[unitmm]
Ta(℃)
LOAD(%)
0
20
40
60
80
100
120
-10 0 10203040506070 8
0
MOUNTINGA
(STANDARDMOUNTING)
MOUNTINGB DONTUSE DONTUSE
HWS300/ME
2XWOLQH'UDZLQJ
2XWSXW'HUDWLQJ


Instruction Manual
HWS HWS HD HWS ME HWS-P
Pleasereferto"TDK-Lambda
EMCFilters"catalog.
RecommendedEMCFilter

ITEMS/UNITS LEDOM
HWS600-5/ME HWS600-12/ME HWS600-15/ME HWS600-24/ME HWS600-48/ME

 

 

   
     
     
      
      
 

 

     

      
       
 
 

  
 


 

 

 

 




 




















HWS600/ME
+:60(6SHFLILFDWLRQV5HDGLQVWUXFWLRQPDQXDOFDUHIXOO\EHIRUHXVLQJWKHSRZHUVXSSO\XQLW


Instruction Manual
HWS HWS HD HWS ME HWS-P
SOCKET HOUSING
TERMINAL PINS
HAND CRIMPING TOOL
PHDR-12VS
SPHD-002T-P0.5(AWG2824)
SPHD-001T-P0.5(AWG2622)
YRS-620(SPHD-002T-P0.5)
YC-610R(SPHD-001T-P0.5)
MANUFACT
JST
JST
JST
PART DESCRIPTION
PIN HEADER
PART NAME
S12B-PHDSS
MANUFACT
JST
== SIGNAL CONNECTOR USED ==
== MATCHING HOUSINGS , PINS & TOOL ==
AIRFLOW
== ACCESSORIES ==
*COVER FOR BARRIER TERMINAL STRIP -----1
(ATTACHED ON TERMINAL AT SHIPMENT)
*SHORT PIECE --------------------1
SHORTING +Vm+S, -Vm-S, CNTTOG
(ATTACHED ON CN1 AT SHIPMENT)
PART DESCRIPTION
PART NAME
26MAX
(37.7)1617.516
7.2
(88.8) 3-M4
10 10 (10)
100±1
(79.5)
4-M5
(14.6)
(14.6)
15
(44.5)
(63.9)
82±1
40±0.560±0.520 21
18MAX
25 120±0.5
110±0.5
5MAX
20
165±1
[UNITSmm]
NAMEPLATE 8-M4TAPPEDHOLES
SCREWPENETRATIONDEPTHMAX.6mm
8-M4TAPPEDHOLES
SCREWPENETRATIONDEPTHMAX.6mm
【HWS600/ME】
Ta(℃)
LOAD(%)
0
20
40
60
80
100
120
-10 0 10203040506070 80
MOUNTINGA
(STANDARDMOUNTING)
MOUNTINGB DONTUSE DONTUSE
HWS600/ME
2XWSXW'HUDWLQJ
2XWOLQH'UDZLQJ


Instruction Manual
HWS HWS HD HWS ME HWS-P
ITEMS/UNITS MODEL HWS1000-24/ME HWS1000-36/ME HWS1000-48/ME
Input
Voltage Range (*2) V AC85 - 265 or DC120 - 330
Frequency (*2) Hz 47 - 63
Power Factor (100/200VAC)(typ) (*1)
0.98/0.95
Efficiency (100/200VAC)(typ) (*1) 85/87 85/88 86/88
Current (100/200VAC)(typ) (*1) A 13.5/7.0
Inrush Current (100/200VAC)(typ) (*3)
A20/40
Leakage Current (*10) mA Less than 0.5 (0.2(Typ) at 100VAC / 0.4(typ) at 230VAC)
Output
Nominal Voltage VDC 24 36 48
Maximum Current A 46 30.7 23
Maximum Peak Current (*13) A 58.5 39 29.2
Maximum Power W 1104
Maximum Peak Power (*13) W 1404
Maximum Line Regulation (*5) mV 96 144 192
Maximum Load Regulation (*6) mV 150 300
Temperature Coefficient Less than 0.02%/
Maximum
Ripple & Noise (*4)
0 to +71
mVp-p
150 200
-10 to 0
mVp-p
180 240 500
Hold-up Time (typ) (*9) ms 20
Voltage Adjustable Range VDC 19.2-28.8 28.8-43.2 38.4-52.8
Function
Over Current Protection (*7) A >61.4 >40.9 >30.6
Over Voltage Protection (*8) VDC 30.0-34.8 45.0-49.7 55.2-60.0
Remote Sensing Possible
Remote ON/OFF Control Possible
Parallel Operation Possible
Series Operation Possible
Monitoring Signal PF(Open collector output)
Line DIP Built to meet SEMI-F47 (200VAC Line only)
Environment
Operating Temperature (*11) -10 to + 71, Start up -20 to +71
-10 to +40C100
+50C100
+71C50
Storage Temperature -30 to +85
Operating Humidity RH 10 - 90 (No Condensing)
Storage Humidity RH 10 - 95 (No Condensing)
Vibration At no operating, 10 - 55Hz (Sweep for 1min.)
19.6m/s² Constant, X,Y,Z 1hour each.
Shock (In package) Less than 196.1m/
Cooling Forced Air By Blower Fan
Isolation
Withstand Voltage Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Output-FG : 500VAC (300mA), Output-CNT:100VAC (100mA) for 1min.
Isolation Resistance More than 100M: Output - FG : 500VDC
More than 10M: Output - CNT : 100VDC at 25 and 70%RH
Standards
Safety Standards (*12) Approved by UL60601-1, EN60601-1,CSA C22.2 No.601.1-M90(C-UL)
PFHC Built to meet IEC61000-3-2
Voltage Fluctuations/Flicker Emissions
Built to meet IEC61000-3-3
EMI Built to meet EN55011/EN55022-A, FCC-ClassA, VCCI-ClassA, CISPR-ClassA.
Immunity Built to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3),
-5(Level 3,4), -6(Level 3), -8(Level 4), -11
Mechanical
Weight (max) g 3200
Size (W×H×D) mm 126.5 x 82 x 240 ( Refer to Outline Drawing )
(*1) At Ta=25 and maximum output power.
(*2) For cases where conformance to various safety specs (UL, CSA, EN) are required,input voltage range will be 100 - 240VAC(50/60Hz).
(*3) First in-rush current. Not applicable to the first 0.2ms in-rush current flowing into the power supply noise filter.
(*4) Measure with JEITA RC-9131A probe, Bandwidth of scope :100MHz. (at 100uF electric capacitor and 0.47uF film capacitor on the test fixture board.)
(*5) 85 - 265VAC , constant load.
(*6) No load-Full load, constant input voltage.
(*7) Constant current limit with automatic recovery. Over current condition for more than 5 seconds will cause the
output to shutdown.
Output current exceeding maximum rated output current for more than 10 seconds continuously
will result to output shutdown.
(*8) OVP circuit will shut down output, manual reset (Power cycle) or ON/OFF CNT signal reset.
(*9) At 100/200VAC, nominal output voltage and maximum output current.
(*10) Measured by the each measuring method of UL, CSA, EN and DENAN (at 60Hz), Ta=25 .
When using it as a patient care equipment, all outer surfaces of the equipment
shall be constructed of nonconductive material. See clause 19.5DV.2 of UL60601-1.
(*11) Ratings - Derating at standard mounting.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- As for other mountings, refer to derating curve.
(*12) As for UL60601-1, EN60601-1 and CSA-C22.2 No.601.1-M90(C-UL) basic insulation.
(*13) Peak output current is less than 10 seconds, and duty 35% max. (200VAC Line only)
Pleasereferto"TDK-Lambda
EMCFilters"catalog.
RecommendedEMCFilter

HWS1000/ME
+:60(6SHFLILFDWLRQV
5HDGLQVWUXFWLRQPDQXDOFDUHIXOO\EHIRUHXVLQJWKHSRZHUVXSSO\XQLW


Instruction Manual
HWS HWS HD HWS ME HWS-P












  













 



 















(/
1$&
【HWS1000/ME】


  
  
   
  
 
   
 
 





 





 

 
 







    

   

HWS1000/ME
2XWSXW'HUDWLQJ
2XWOLQH'UDZLQJ


Instruction Manual
HWS HWS HD HWS ME HWS-P
ITEMS/UNITS MODEL HWS1500-24/ME HWS1500-36/ME HWS1500-48/ME
Input
Voltage Range (*2) V AC85 - 265
Frequency (*2) Hz 47 - 63
Power Factor (100/230VAC)(typ)
(*1)
0.98 / 0.94
Efficiency (100/200VAC)(typ) (*1) % 84 / 88 86 / 90
Current (100/200VAC)(typ) (*1) A 19.0 / 10.0
Inrush Current (100/200VAC)(typ)
(*3)
A 20 / 40
Leakage Current (*10) mA Less than 0.5. (0.2 (typ) at 100VAC / 0.4 (typ) at 230VAC)
Output
Nominal Voltage VDC 24 36 48
Maximum Current (100/200VAC) A 65 / 70 42 / 46.5 32 / 32
Maximum Peak Current (*13) A 105 70 -
Maximum Power (100/200VAC) W 1560 / 1680 1512 / 1674 1536 / 1536
Maximum Peak Power (*13) W 2520 -
Maximum Line Regulation (*5) mV 96 144 192
Maximum Load Regulation (*6) mV 144 150 288
Temperature Coefficient Less than 0.02%/
Maximum
Ripple & Noise (*4)
0 to +70
mVp-p
200
-10 to 0
mVp-p
240 400
Hold-up Time (typ) (*9) ms 20
Voltage Adjustable Range VDC 19.2 - 28.8 28.8 - 43.2 38.4 - 52.8
Function
Over Current Protection (*7) A >110.2 >73.5 >33.6
Over Voltage Protection (*8) VDC 30.0 - 34.8 45.0-49.7 55.2 - 64.8
Remote Sensing Possible
Remote ON/OFF Control Possible
Parallel Operation Possible
Series Operation Possible
Monitoring Signal PF (Open collector output)
Line DIP Built to meet SEMI-F47 (200VAC Line only)
Environment
Operating Temperature (*11) -10 to +70 ( -10 to +50: 100%, +60: 75%, +70: 50%), start up -20 to 70
Storage Temperature -30 to +85
Operating Humidity %RH 10 - 90 (No Condensing)
Storage Humidity %RH 10 - 95 (No Condensing)
Vibration At no operating, 10 - 55Hz (sweep for 1min.) 19.6m/s² constant, X, Y, Z 1hour each.
Shock (In package) Less than 196.1m/
Cooling Forced air by blower fan
Isolation
Withstand Voltage Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Output-FG : 500VAC (300mA), Output-CNT:100VAC (100mA) for 1min.
Isolation Resistance More than 100M: Output - FG : 500VDC
More than 10M: Output - CNT : 100VDC at 25 and 70%RH
Standards
Safety Standards (*12) Approved by UL60601-1, EN60601-1, CSA C22.2 No.601.1-M90 (C-UL)
PFHC Built to meet IEC61000-3-2
Voltage Fluctuations / Flicker Emissions
Built to meet IEC61000-3-3
EMI Approved by EN55011 / EN55022-A, FCC-Class A, VCCI-Class A
Immunity Built to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3),
-5(Level 3,4), -6(Level 3), -8(Level 4), -11
Mechani-
cal
Weight (typ) g 3800
Size (W x H x D) mm 126.5 x 82 x 280 (Refer to outline drawing)
(*1) At Ta=25 and maximum output power.
(*2) For cases where conformance to various safety specs (UL, CSA, EN) are required, input voltage range will be 100 - 240VAC (50/60Hz).
(*3) First in-rush current. Not applicable to the first 0.2ms in-rush current flowing into the power supply noise filter.
(*4) Measure with JEITA RC-9131A probe, Bandwidth of scope :100MHz. (at 100uF electric capacitor and 0.47uF film capacitor on the test fixture board.)
(*5) 85 - 265VAC, constant load.
(*6) No load-Full load, constant input voltage.
(*7) Constant current limit with automatic recovery. Over current condition for more than 5 seconds will cause the
output to shutdown.
Output current exceeding maximum rated output current for more than 10 seconds continuously
will result to output shutdown.
(*8) OVP circuit will shut down output, manual reset (Power cycle) or ON/OFF CNT signal reset.
(*9) At 100/200VAC, nominal output voltage and maximum output current.
(*10) Measured by the each measuring method of UL, EN and CSA (at 60Hz).
When using it as a patient care equipment, all outer surfaces of the equipment shall be
constructed of nonconductive material. See clause 19.5DV.2 of UL60601-1.
(*11) Ratings - Derating at standard mounting.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- As for other mountings, refer to derating curve.
(*12) As for UL60601-1, EN60601-1 and CSA-C22.2 No.601.1-M90 (C-UL) basic insulation.
(*13) Peak output current is less than 10 seconds, and duty 35% max. (200VAC Line only)
Pleasereferto"TDK-Lambda
EMCFilters"catalog.
RecommendedEMCFilter

HWS1500/ME
+:60(6SHFLILFDWLRQV
5HDGLQVWUXFWLRQPDQXDOFDUHIXOO\EHIRUHXVLQJWKHSRZHUVXSSO\XQLW


Instruction Manual
HWS HWS HD HWS ME HWS-P
82±1
(56.8)
(11.2)
(23.3)
(15.1) 4-M4
OUTPUT
TERMINAL
I
NPUT
TERMINAL
(9.1)
(73.6)
126.5±1
111111
20 10
3
46MAX
260±0.5
260±0.5
280±1 4MAX
10
20MAX
10
22
3
23.7±125±1
112±0.5
60±0.511 7.25
35±1
4-M4
2 -φ9
45.4±1 20
20±1 8-M4TAPPEDHOLES(BOTHSIDES)
SCREWPENETRATIONDEPTHMAX.6mm
8-M4TAPPEDHOLES(BOTHSIDES)
SCREWPENETRATIONDEPTHMAX.6mm
NAMEPLATE
NAMEPLATE
I/OSIGNALCONNECTOR(SEENOTEA)
BUSBAR
SPACER
(BLACK)
BUSBAR
SPACER
(RED)
AIR
FLOW
[unitmm]
[Chassismatrial:SPCC-SD
【HWS1500/ME】


   
   
    
  
  
   
 
 


    

   

MOUNTINGA
(STNDARDMOUNTING)
MOUNTINGB MOUNTINGC MOUNTINGD DON'TUSE DON'TUSE






      









 



 

HWS1500/ME
2XWSXW'HUDWLQJ
2XWOLQH'UDZLQJ
aHWS35
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
%ORFN'LDJUDP
●Circuittopology,switchingfrequency
Cascadeforwardtopology190kHz(fixed)
PFHCcircuit:activefilter
HWS300:80kHz(fixed),HWS600:90kHz(fixed)
●Fuserating:
HWS300:10A,HWS600:15A
LineFilter
Rectifier
PFHCCircuit
InrushCurrentLimitCircuit
Filter
Rectifier&Filter
SwitchingCircuit
ControlCircuit
ControlCircuit
OCP
Circuit
OVP
Circuit
Photo-
Coupler
Photo-Coupler
OutputSensing
FanALM
PowerFail
OutputCurrentBalance
Photo-Coupler
Photo-Coupler
OVP
Sensing
RemoteON/OFF
Control
L
N
FG
Input
85-265VAC
+Vm
+S
−Vm
COM
PC
PF
CNT
TOG
PV
−S
Output
*Optional
【HWS300,HWS600】

 




  



 







REF


































 














【HWS1000】
HWS 300- 1000
aHWS36
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 1500, 1800T








  



 










































 






【HWS1500】
【HWS1800T】
%ORFN'LDJUDP


 
 
 
L1
Input L2
L3
FG
170〜265VAC
Inrush
Current
Limit
Circuit
Line
Filter Rectifier PFHC
Circuit
Switching
Circuit
Primary Circuit Secondary Circuit
Rectifier
&
Filter
+S
Output
COM
PV
PC
REF
PF
TOG
Remote
ON/OFF
Control
Output
Current
Balance
Reference
Voltage
Output
Sensing
Low output
Voltage
Detection
OVP
Sensing
Delay
Timer
LVP
Circuit
OVP
Circuit
Latch
Circuit
PFHC
Control
Circuit
Open
Phase
Detection
Supplemental
Power supply
OCP
Circuit
Thermal
Protection
Blower
Fan
SELV Circuit
(60V: Hazardous Voltage Circuit)
CNT
+
Filter
Switching
Control
Circuit


 
 
 
aHWS37
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 300, 600, 1000
【HWS300,HWS600】
InputVoltage 0V
OVPPoint(*2
PFMonitorPoint(65-80%ofNominalVoltage)
Vout
0V
H(CNT)
L(TOG)
L(TOG)
H(PF)
OutputVoltage
RemoteON/OFF
Control(*1)
PowerFail
PFSignal
(OpenCollector)
INPUTON
INPUTON
OTPACTON
FANSTOP
INPUTOFF
INPUTON
INPUTOFF
INPUTOFF
REMOTEOFF
REMOTEON
OVPACTON
REMOTEOFF
REMOTEON
OVPACTON
(*1Level
2.4V≦H≦12VorOpen
0V≦L≦0.8VorShort
(*2OVPPoint
3V125-150%
5-24V125-145%
48V115-135%
OVERLOADRELEASED
OVERLOADCONDITION
6HTXHQFH7LPH&KDUW
InputVoltage
OutputVoltage
RemoteON/OFF
Control(*1
PFSignal
(OpenCollector)
INPUTON
REMOTEOFF
REMOTEOFF
REMOTEOFF
REMOTEON
REMOTEON
REMOTEOFF
REMOTEON
REMOTEOFF
REMOTEON
REMOTEON
INPUTOFF
INPUTOFF
INPUTOFF
INPUTOFF
INPUTOFF
INPUTON
INPUTON
INPUTON
INPUTON
INPUTON
OVPACTON
OCPACTON
OCPACTON
OCPACTON
OVPACTON
OCPRESET
OCPSHUTDOWN
OCPSHUTDOWN
FANSTOP
FANSTOP
FANALMACTON
FANALMACTON
OTPACTON
OTPACTON
0V
0V
Vout
H
L
L
H
PFMonitorPoint
(Lessthan80%)
OCPPoint(*3
(Morethan105%)
OCPPoint(*3
(Morethan105%)
OCP
Shutdown
OCP(Shutdown)
OVPPoint(*2 OVPPoint(*2
5sec
(TYP)
5sec
(TYP)
5sec
(TYP)
5sec
(TYP)
(*1 Level
2.4V≦H12VorOpen
0V≦L0.8VorShort
(*2 OVPPoint

3-7V125-140
12,1524V125-145
36V125-138
48,60V115-125
(*3 OCPPoint(7V-60VModel,InputvoltageAC180-265V)
Peakcurrent120(7V),114%(12V,15V),127(24V-60V)
Peakcurrentislessthan10seconds,andduty35%max.
Overloadexceeding105%(withoutoutputdroppingSituation)continuouslyfor
morethan10secondswillresulttooutputshutdown.
Meanwhile,overloadexceeding105%(withoutputdropping)continuouslyfor
morethan5secondswillresulttooutputshutdown.
OCPPointMorethan120%(7V),Morethan114%(12V,15V),
Morethan127(24V-60V)
【HWS1000】
aHWS38
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 1500T, 1800T
6HTXHQFH7LPH&KDUW
【HWS1500】
InputVoltage 0V
Vout
0V
H
L
L
H
OutputVoltage
RemoteON/OFF
Control(*1
PFSignal
(OpenCollector)
INPUTON
INPUTON
OVPACTON
INPUTON
OCPACTON
OCPRESET
OCPACTON
OCPSHUTDOWN
OTPACTON
FANSTOP
INPUTOFF
INPUTOFF
REMOTEOFF
REMOTEON
(*1Level
2.4V≦H≦12VorOpen
0V≦L≦0.8VorShort
(*2OVPPoint
3-7V 125-140
12,15,24V125-145%
36V 125-138%
48V 115-135%
60V 115-125
REMOTEOFF
REMOTEON
OCPACTON
OCPSHUTDOWN
REMOTEOFF
REMOTEON
REMOTEOFF
REMOTEON
REMOTEOFF
REMOTEON
INPUTOFF
INPUTON
INPUTOFF
INPUTOFF
INPUTON
INPUTON
OVPACTON
FANALMACTON
FANSTOP
FANALMACTON
OTPACTON
PFMonitorPoint
(Lessthan80%)
OVPPoint(*2
OVPPoint(*2
OCPPoint
(Morethan105%)
5sec
(TYP)
5sec
(TYP)
5sec
(TYP)
5sec
(TYP)
OCP(Shutdown) OCP(Shutdown)
(*3
OCPPoint
(Morethan105%)
(*3
(*3 OCPPoint(6V7V,24V,36V,60VModel,InputvoltageAC180-265V)
Peakcurrent120(6V7V),150%(24V,36V,60V)
Peakcurrentislessthan10seconds,andduty35%max.
Overloadexceeding105%(withoutoutputdroppingsituation)continuouslyfor
morethan10secondswillresulttooutputshutdown.
Meanwhile,overloadexceeding105%(withoutputdropping)continuouslyfor
morethan5secondswillresulttooutputshutdown.
OCPPointMorethan120(6V7V),Morethan150%(24V,36V,60V)
【HWS1800T】
InputVoltage
OutputVoltage
RemoteON/OFF
Control(*1
PFSignal
(OpenCollector)
INPUTON
REMOTEOFF
REMOTEOFF
REMOTEOFF
REMOTEON
REMOTEON
REMOTEOFF
REMOTEON
REMOTEOFF
REMOTEON
REMOTEON
INPUTOFF
INPUTOFF
INPUTOFF
INPUTOFF
INPUTOFF
OUTPUTSHUTDOWN
INPUTOFF
INPUTON
INPUTON
INPUTON
INPUTON
INPUTON
INPUTON
OPENPHASEACTON
OVPACTON
OCPACTON
OCPACTON
OCPACTON
OVPACTON
OCPRESET
OCPSHUTDOWN
OCPSHUTDOWN
FANSTOP
FANSTOP
FANALMACTON
FANALMACTON
OTPACTON
OTPACTON
0V
0V
Vout
H
L
L
H
PFMonitorPoint
(Lessthan80%)
OCPPoint
(Morethan105%)
OCPPoint(*3
(Morethan105%)
OCP(Shutdown) OCP(Shutdown)
OVPPoint(*2
OVPPoint(*2
(*3
5sec
(TYP)
5sec
(TYP)
5sec
(TYP)
5sec
(TYP)
(*1 Level
2.4V≦H≦12VorOpen
0V≦L≦0.8VorShort
(*2 OVPPoint

3-7V125-140%
12,15,24V125-145
36V125-138%
48,60V115-125
(*3 :OCPPoint
Peakcurrent120(6V-15V)140(24V-60V)
Peakcurrentislessthan10seconds,andduty35%max.
Overloadexceeding105%(withoutoutputdroppingsituation)continuouslyfor
morethan10secondswillresulttooutputshutdown.
Meanwhile,overloadexceeding105%(withoutputdropping)continuouslyfor
morethan5secondswillresulttooutputshutdown.
OCPPointMorethan120(6V-15V)Morethan140(24V-60V)
OpenPhase
aHWS39
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 300, 600
+:66HULHV,QVWUXFWLRQ0DQXDO
Besuretoreadthefollowingprecautionsthoroughlybeforeus-
ingthispowersupplyunit.
Payattentiontoallwarningsandcautionsbeforeusingtheunit.
Incorrectusagecouldleadtoanelectricshock,damageorafire
hazard.
WARNING
●Donotmakeunauthorizedchangestopowersupplyunit,oth-
erwiseyoumayhaveelectricshockandvoidwarranty.
●Donottouchtheinternal components,theymay havehigh
voltageorhigh temperature.Youmay getelectricshockor
burned.
●Whentheunitisoperating,keepyour handsandfaceaway
fromit;anaccidentmayinjureyou.
●Donotuseunitunderunusualconditionsuchasemissionof
smokeorabnormalsmellandsoundetc.Itmightcausefire
andelectricshock.
Insuchcase,pleasecontactus;donotrepairbyyourself,as
itisdangerousfortheuser.
●Donotdroporinsertanythingintounit.Itmightcausefailure
andfire,whenusingtheunitundersuchcondition.
●Donotoperatetheseunitsattheconditionofcondensation.
Itmaycausefireandelectricshock.
●Theoutputsoftheseproductsmustbeearthedintheenduse
equipmenttomaintainSELV.
Iftheoutputsarenotearthed,theymustbeconsideredhaz-
ardousandmustnotbemadeuseraccessible.
CAUTION
●Thispowersupplyisprimarilydesignedandmanufacturedto
useandencloseinotherequipment.
●Thispowersupplyunit hasabuilt-infan forair-cooling.Do
notblockairintakeandexhaust.Itmightcausefire.
●Inputvoltage,outputcurrent,outputpower,ambienttempera-
tureandambient humidityshouldbewithin specifications,
otherwisetheunitwillbedamaged.
●The unitmightbe brokendownby accidentorunexpected
situation.Forapplicationequipment,whichrequiresveryhigh
reliability(nuclearrelated equipment,trafficcontrol equip-
ment,medicalequipment, etc.),pleaseprovide failsafety
functionintheequipment.
●Donotmakeanimproperwiringtoinputandoutputterminals.
Itmaycausedamage.
●Do notusein environmentsuchas strongelectromagnetic
field,erosivegas etc,orany environmentwhereconductive
foreignsubstancemayenter.
●Donotoperateandstorethisunitattheconditionofconden-
sation.Insuchcase,waterprooftreatmentisnecessary.
●Donotoperatethisunitafteritfallsdown.
●Theoutputvoltageofthis powersupplyis consideredtobe
ahazardousenergylevel,andmustnotbeaccessibletoan
operator.
NotesforHWS30-150/MEIEC/EN/UL60601-1
NOTES
●Theproductshouldbecompletelyenclosedintheapplication
accordingtothespecifications,andcontactto theI/Opart
withthepatientbelimited.Becarefulwhendesigningtheout-
line.Pleaserefertosection16,IEC/EN/UL60601-1.
●Thisproductisnotsuitablefortheuseofthecombustiblenar-
coticthatoxygenorthenitrousoxidemixed.
●Thesignalportconnects onlythedevicethatsuitsIEC/EN/
UL60601-1.
●Itisnecessarytofuseitintwopolesofthemainpowersup-
plyintheoverallequipmentintowhichthisproductisbuiltex-
cludingthepermanentinstallationtypeequipmentdefined by
IEC/EN/UL60601-1section57.6.Thefuseisinstalledinthe
monopoleoftheinputofthisproduct(liveline).
●BetweenI/Oofthisproductisevaluatedasthebasicinsula-
tionbyIEC/EN/UL60601-1.Pleaseaddfurtherinsulationfor
safecontacttotheoutputpart.
●Pleaserefertolocalregulationsforthedisposaloftheproduct
thatpassesthelife.
●Theleakecurrentofthisproductinnormalconditionis500uA
orless.(Atinputvoltage230VAC.)Theunitis suitablefor
medicalequipment asprovided byIEC/EN/UL60601-1.In
theapplicationaccording tothe UL60601requirement, itis
assumedthatsurfacesofallequipmentisassembledwiththe
insulatingmaterials.
●ThisproductisnotevaluatedbyIEC/EN/UL60601-1-2(EMC).
However,EMCtestdataisavailableatTDK-Lambda.
BEFOREUSINGTHEPOWERSUPPLYUNIT
aHWS40
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
PinNo Configuration Function
1 Vm +Outputmonitorterminal.Connectedto+OutputterminalinthisPowersupplyunit.
(+Vmterminalcannotsupplyloadcurrent.)
Remotesensingterminalfor+output.
2 S (Forremotesensingfunction,whichcompensates for linedropbetweenpowersupplyterminalsand
loadterminals.Connectto+Vmterminalwhenremotesensingfunctionunnecessary.)
3 Vm -Outputmonitorterminal.Connectedto-OutputterminalinthisPowersupplyunit.
(-Vmterminalcannotsupplyloadcurrent.)
Remotesensingterminalfor-output.
4 S (Forremotesensingfunction,whichcompensates for linedropbetweenpowersupplyterminalsand
loadterminals.Connectto -Vm terminal whenremotesensingfunctionunnecessary.)
5 PC Currentbalanceterminal.(Foroutputcurrentbalancinginparalleloperation.)
6 COM GNDforPCandPVsignals.
 PV Outputvoltageexternalcontrolterminal.
7(Optional) (Forpowersupplyoutputvoltagecontrolwithanexternalvoltage.
StandardmodelsdonthavethisfunctionandindicateNCmarkatpanel.
8 NC Noconnect
9 CNT RemoteON/OFFcontrolterminal.(PowersupplyON/OFFcontrolwithanexternalsignal.)
10 TOG GNDforCNTandPFsignals.(SameasPinNo.12)
Powerfailsignal(PFsignal)outputterminal.
11 PF (As theoutputvoltagedrops,orFANstops and ACinputvoltagedown,Power Failterminalwill
outputHigh.
12 TOG GNDforCNTandPFsignals.(SameasPinNo.10)
CN1
1
3
5
7
9
11
2
4
6
8
10
12
1
3
5
7
9
11
2
4
6
8
10
12
CN2
󱳝CN1,CN2ConnectorpinConfigurationandFunction
CN1andCN2aresamepinconfigurationandfunction.
Theyareconnectedtoeachotherinthispowersupplyunit.
WhenthepinofCN1sideisshorted,thesamefunctionpinsofCN2sidearealsoshorted.
PleasenotethatthefunctioncannotbeseparatelysetwithCN1andCN2.
CN1,CN2 Connector&Housing&TerminalPin
PARTDESCRIPTION PARTNAME MANUFACT
PINHEADER S12B-PHDSS JST
SOCKETHOUSING PHDR-12VS JST
TERMINALPINS SPHD-002T-P0.5(AWG28-24)
SPHD-001T-P0.5(AWG26-22)
JST
HANDCRIMPINGTOOL YRS-620(SPHD-002T-P0.5)
YC-610R(SPHD-001T-P0.5)
JST
①V.ADJ:Outputvoltageadjustmenttrimmer.
(Theoutputvoltageriseswhenatrimmeristurnedclockwise.)
②ON:Output(PowerOn)indicationLED
(Theindicatorturnsonwhenthepowersupplyoutputisinnor-
maloperatingcondition.)
③CN1,CN2:Remotesensing,ON/OFF controlsignal,Current
balancesignal,Powerfailsignal,Outputvoltage
externalcontrolsignal.(Referto2-2.)
④ :ProtectiveEarth(Frameground),M4screw.
⑤ACinputterminalL:LiveLine(Fuseinline),M4screw.
⑥ACinputterminalN:Neutralline,M4screw.
⑦+:+Outputterminal
 (HWS300:M4screwx2/HWS600:M5screwx2)
⑧−:−Outputterminal
 (HWS300:M4screwx2/HWS600:M5screwx2)
●HWS300
1.TerminalExplanation
Pleasepayextra attentiontothe wiring.Incorrectconnection
willdamagethepowersupply.
●HWS600
CN1
CN2
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
Outputvoltagedetectioncircuit
OutputON/OFFcontrolcuicuit
Powerfailsignalgenerationcircuit
Outputcurrentsignalcircuit
300,
*OutputON/OFFcontrolcircuitandthepowerfailsignalcircuitareinsulated
withothercircuitsinthepowersupply(insulatingvoltageAC100V).
󱳛FrontPanelExplanation
HWS 300, 600
aHWS41
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
ConnectingcircuitwithCN1orCN2connector
1
2
3
4
5
6
7
8
9
10
11
12
ConnectingcircuitwithCN1orCN2connector
1
2
3
PFsignaloutput
signalground
4
5
6
7
8
9
10
11
12
Attachedconnectorwhenshipping ConnectingcircuitwithCN1orCN2connector
1
2
3
4
Twistedwire
5
6
7
8
9
10
11
12
Red Black Yellow
1
2
3
4
5
6
7
8
9
10
11
12
"+"ofload
"-"ofload
●Whenconnecting inputandoutput wiring,andCN1, CN2,
inputAC-Lineshouldbeoff.
●Inputwiringandoutput wringshallbe separatedtoimprove
noisesensibility.
●Theprotectiveearth(PE)mustbeconnectedtothe termi-
nalorchassis.
●Remotesensinglinesshallbetwistedorusedwithshielded
wired.
RemoteON/OFF controllinesshallbe twistedorused
shieldedwires.Separatefromloadline.
●Outputcurrentofeachterminalscrewshallbelessthan40A
forHWS300.Andshallbelessthan60AforHWS600.
2.TerminalConnectionMethod
Pleasepayextra attentiontothe wiring.Incorrectconnection
willdamagethepowersupply.
HWS300PanelSide(CommonHWS600)
ON
CN1(or CN2)
V.ADJ
CN
LOAD
1
2
L
N
-+
ON
CN1(or CN2)
V.ADJ A
A
B
B
twist or s
CN
LOAD
1
2
L
N
-+
LOAD
-+
ON
CN1(or CN2)
V.ADJ
CN
1
2
L
N
ON
CN1(or CN2)
V.ADJ
PF
signal
output
signal
ground
CN
LOAD
1
2
L
N
-+
ON/OFFcontrolrequired
TOGterminalisgroundforCNTterminal.
PFsignaloutputrequired
Opencollectormethodshownbelowshallbeused.
TOGterminalisgroundforPFterminal.
Basicconnection(Localsensing)
Connect+Sterminalto+Vmterminaland
−Sterminalto−Vmterminal.Connect
CNTterminaltoTOGterminalwiththeattachedcon-
nector.
Remotesensingrequired
Connect+Sterminal to+ terminalofloadand-S
terminalto-outputterminalofloadwithwires.
HWS 300, 600
aHWS42
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
󱫀InputVoltageRange
Inputvoltagerangeissinglephase85-265VAC(47-63Hz)or
120-330VDC.Inputvoltage,whichisoutofspecification,may
causeunitdamage.Ratedinputvoltageforsafetystandardap-
plicationis100VAC-240VAC(50/60Hz).
󱫂OutputVoltageRange
Outputvoltageis settothe ratedvalueatshipment.V.ADJ
trimmeronthefrontpanelsidemaybeusedtoadjusttheout-
putvoltagewithintherangespecified.
Outputvoltagerange iswithin ±20%of ratedoutputvoltage
(48VOutputModel:-20%to+10%).
Toturnthe trimmerclockwise,the outputvoltagewill bein-
creased.Takenote whentheoutput voltageisincreasedex-
cessively,overvoltage protection(OVP)function maytrigger
andoutputvoltagewillbeshutdown.
󱫄OverVoltageProtection(OVP)
TheOVPfunction (invertershutdownmethod, manualreset
type)isprovided. OVPfunctionoperates within125-145%of
theratedoutputvoltagevalue(48Vtype:115-135%),andthe
outputwillbeshutdownwhenOVP functiontriggers.To re-
setOVP,removetheinputofpowersupplyforafewminutes,
andthenre-input.Or,useCNTreset(remoteON/OFF:OFFto
ON).OVPvalueisfixedandnottobeadjustedexternally.
Neverapplymorethanratedoutputvoltagetooutputterminal,
whichmayleaddamage.Inthecaseofinductiveload,usede-
couplingdiodeatoutputline.
󱫆OverCurrentProtection(OCP)
TheOCPfunctionisprovided.OCPcharacteristicisconstant
currentlimiting,(less than5Voutput model:withHiccup op-
eration)automaticrecovery. OCPfunctionoperates whenthe
outputcurrentexceeds 105%(24Voutputmodel:119%)of
maximumDCoutput currentspecification.The outputwill be
automaticallyrecoveredwhen theoverloadcondition iscan-
celed.Neveroperate theunitunder overcurrentorshorted
conditionsformorethan30seconds,whichmayleaddamage.
OCPsettingisfixedandnottobeadjustedexternally.
󱫈
OverTemperatureProtection(OTP)
TheOTPfunction(manualresettype)isprovided.Whenambi-
entorinternaltemperaturerisesabnormally,OTPfunctionop-
eratesandoutputwillbeshutdown.Aftershutdown,remove
theinputandcoolitdowntoresetOTP.
Thenre-input.
󱫊
LowOutputDetectionCircuit(PF)
Lowoutputvoltagedetectioncircuitisprovided.PowerFail(PF)
signalwillturnHighlevelto indicatetheabnormalstatus
whentheoutputvoltagebecomeswithin65-80%ofratedval-
uecausedbyeitherthedroporbrownoutoftheinputvoltage
orOCP,OVP andOTPfunction operation.Whenthebuilt-in
FANmotorofthispowersupplyunitstops,PFsignalwillturn
toH.The PFsignalisisolatedfrom inputandoutput bya
photo-coupler.Itusestheopencollectormethodshownbelow.
TOG
PF VCEmax30V
ICmax20mA
󱫌
RemoteSensing(+S,-Sterminal)
Thisfunctioncompensates voltagedropof wiringfromoutput
terminalstoload terminals.Connect+S terminalto+
terminalofloadand-Sterminalto-terminalofloadwith
sensingwires.The totallinevoltage drop(+sidelineand -
sideline)shall belessthan 0.3V.Incase thatsensinglines
aretoolong,itisnecessarytoputanelectrolyticcapacitorin
following3places;
Power
Supply
Load
+S
+
-
-
S
+
+
-
+
+
1)acrosstheloadterminal,
2)between+Sterminaland
+terminal,
3)betweenSterminaland
terminal.
Whenthefunctionofremotesensingisnotused,connect+S
terminalto+Vmterminal,and‒Sterminalto‒Vmterminalby
theattachmentconnector.
Ifremotesensing terminalsareopened, thestabilityand the
accuracyoftheoutputdeteriorated.Therefore,terminal+S,-S
mustbeconnected.
󱫎RemoteON/OFFControl
RemoteON/OFFcontrolisprovided.
Usingthisfunction,outputon/offisallowedtocontrolwithout
inputvoltageon/off. Theoutputis turnedtoONwhenTOG
andCNTterminals areshorted,and theoutputisturnedto
OFFwhenthese terminalsareopened. Whenthefunctionis
notused,connectTOGandCNTterminals.Thestandardsfor
thisfunctionareasfollows.TOGterminalisreturnforCNT
terminal.
(1)TTLcompatible.ThemaximuminputvoltagetoCNTter-
minalis12V, andthemaximum allowablereversevolt-
ageis-1V.ThesinkcurrentforCNTterminalis3.5mA.
(2)A switchandrelay oratransistorcanbe usedasON/
OFFswitch.
(3)

RemoteON/OFFcontrolcircuitisisolatedfromtheinput
andoutputby aphoto-couplerand canbecontrolled
regardlessoftheoutputpotential(+or-).ConnectTOG
terminaltogroundofcontrolsignal.
3.FunctionsandPrecautions
HWS 300, 600
aHWS43
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
Themodeofcontrol
CNTLevelforTOGTerminal Output Built-inFan
ShortorL(0V-0.8V) ON Rotate
OpenorH(2.4V-12V) OFF Stop
TOG
CNT
SinkCurrent:3.5mA
Relay,Transistor
TTL,etc.
󱫐OutputRipple&Noise
Thestandardspecificationformaximumripplevalueismeasured
specifiedmeasurementcircuit(JEITA-RC9131A).Whenload
linesarelonger, ripple becomeslarger. Inthiscase,electrolytic
capacitor,filmcapacitor,etc.mightbenecessarytouseacross
theloadterminal.Theoutputripple cannotbemeasured accu-
ratelyiftheprobegroundleadofoscilloscopeistoolong.
+
-
Load
CoaxialCable
1.5m50Ω Oscillo
scorp
R:50Ω
C:4700pF
R
C100MHz
Power
Supply
󱫒SeriesOperation
Forseriesoperation,bothmethod(A)and(B)arepossible.
Theremightbeastepintheoutputrisewaveformduringseries
operation.
PowerSupply PowerSupply
Method(B)Method(A)
Load
+Vm
+S
-
Vm
-
S
+Vm
+S
-
Vm
-
S
Load
+Vm
+S
-
Vm
-
S
+Vm
+S
-
Vm
-
S
Load
󱫓ParallelOperation
Currentbalancingfunction isprovided.Both operationsmode
(A)and(B)arepossible.
(A) ToIncreasetheOutputCurrent
CorrectPCtoPCterminalandCOMtoCOMterminal,the
currentbalancingfunction activatesandoutput currentof
eachpowersupply isequivalentlysuppliedto load.Wires
toPCterminals,COMterminalsshallbeasshortaspos-
sibleandsamelengthandtwisted.
1.
Adjusttheoutput voltageofeachpowersupplytobe
samevaluewithin1%or100mVwhicheverissmaller.
2.Usesamelengthandtypeofwiresforallloadlines.
3.Usethepowersupplywithintheratedoutputcurrentfor
allparalleledmodels.
4.Paralleloperationispossibleupto5units.
(B)ToUseasaBackupPowerSupply
1.
Adjusttheoutput voltageofeachpowersupplytobe
samevalue.
2.
Setpowersupplyoutputvoltage higherbytheforward
voltagedropofdiode.
3.
Usewithinthespecificationsforoutputvoltageandout-
putcurrent.
PowerSupply PowerSupply OutputPower(W)=(Vo+Vf)xIo
Vo+Vf
Io
Vo
Vo+Vf
Method(B)Method(A)
Load
+Vm
+S
-
Vm
-
S
PC COM
PC COM +Vm
+S
-
Vm
-
S
Load
+Vm
+S
-
Vm
-
S
+Vm
+S
-
Vm
-
S
󱫔IsolationTest
Isolationresistancebetween outputand (chassis)shall be
morethan100MΩat500VDCandbetweenoutputandCNT・PF
shallbemore than10MΩat 100VDC.Forsafetyoperation,
voltagesettingof DCisolationtester mustbedonebefore the
test.Ensurethatitisfullydischargedafterthetest.
+S
-
S
PC
COM
PV
CNT
TOG
PF
+Vm
+
-
-
Vm
AC(L)
AC(N)
Isolation
Tester
Output-FG(chassis):
500VDC100MΩormore
Output-CNT·PF:
100VDC10MΩormore
+S
-
S
PC
COM
PV
CNT
TOG
PF
+Vm
+
-
-
Vm
AC(L)
AC(N) Isolation
Tester
󱫕WithstandVoltage
Thisseriesis designedtowithstand 3.0kVACbetweeninput
andoutput,2.5kVAC betweeninputand (chassis), 500VAC
betweenoutputand (chassis),and100VACbetweenoutput
andCNT・PFterminal eachfor1 minute.Whentestingwith-
standvoltage,setcurrentlimit ofwithstandvoltagetestequip-
mentat20mA.
(Output- (chassis)andOutput-Control:100mA).
Theappliedvoltage mustbegraduallyincreased fromzero
totestingvalue andthengradually decreasedforshutdown.
Whentimerisused,thepowersupplymaybedamagedbyhigh
impulsevoltageat timerswitchon andoff.Connectinput and
outputasfollows.
+S
-
S
PC
COM
PV
CNT
TOG
PF
+Vm
+
-
-
Vm
AC(L)
AC(N)
+S
-
S
PC
COM
PV
CNT
TOG
PF
+Vm
+
-
-
Vm
AC(L)
AC(N)
Output-(chassis):
500VAC1min.(100mA)
Input-(chassis)(solidline):2.5kVAC1min.(20mA)
Input-Output(dottedline): 3.0kVAC1min.(20mA)
Output-CNT·PF:
100VAC1min.(100mA)
Withstand
Voltage
Tester
+S
-
S
PC
COM
PV
CNT
TOG
PF
+Vm
+
-
-
Vm
AC(L)
AC(N)
Withstand
Voltage
Tester
Withstand
Voltage
Tester
*Thisproducthave monolithicceramiccapacitor insecondary
circuittoframeground.
Someofthe withstandvoltagetestermay generatehighvolt-
ageatthematchingwithmonolithicceramiccapacitorandmay
causetheunitdamage.
Allspecificationsaresubjecttochangewithoutnotice.
HWS 300, 600
aHWS44
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 300, 600
So,pleasecheckthewaveformoftestvoltage.
󱫖
OutputVoltageExternalControl(PV)
Outputvoltageexternal controlfunctionis availableasoption
withmodelname followedby/PV.Outputvoltage canbe
variedbyapplyinganexternalvoltage(1‒6V)toPVterminal
andCOMterminal.Noteifanexternalvoltageisnotapplied,
therewillbenooutput.Andifthebelowconnectionmethodis
attemptedwiththestandardmodels internalcomponentscould
bedamaged.Pleaseconsiderthefollowingcharacteristics.
Externalvoltage
Connectionmethod PowerSupply
Load
+Vm
+S
-
Vm
-
S
PV
COM
110%
120%
Nominal
Output
Voltage
20%
OutputVoltage
6V5.5V5V1V
PVvoltage(NominalInputVoltage)
110%
120%
Nominal
Output
Voltage
OutputVoltage
20%
0
0
LoadCurrent
83%90% 100%
OutputVoltageLinearity
OutputVoltageDerating
Note1.
Regardingoutputvoltage adjustmentbelow20%,
pleaseconsultoursales.
Note2. For48Voutputmodelonly,spacesbelowmustbefol-
lowed.Limitoutput voltagevariationrange at20%-
110%.
AtPVvoltagevariation1V-5.5V.
󱫗OutputPeakCurrent
For24Voutputmodel,pleasemeetthefollowingcondition.Re-
ducepeakcurrentvalueaccordingtooutputderatingassection
5-1.
Dutyupto35(%)
    
Duty= x100(%)
Peakoutputcurrent(A)
Ratedoutputcurrent(A)
Averageoutputcurrent(A)
Peakcurrentpulsewidth(sec)
Period(sec)
InputVoltagerange: AC180V-265V
ContinuousPeakoutputtime(): Within10seconds
Peakoutputcurrent(): Withintheratedpeakoutputcurrent
AverageDCoutputcurrent(): Withintheratedoutputcurrent
󱫀
OutputDeratingaccordingtotheMountingDirections
Recommendedstandardmountingmethodis(A).Method(B)is
alsopossible.Refertothederatingbelow.
󱫂OutputDerating
Allspecificationsaresubjecttochangewithoutnotice.
4.MountingDirections
(A)Standard
Mounting
(B) (C)Inhibit (D)Inhibit
HWS300
(A)Standard
Mounting
(B) (C)Inhibit (D)Inhibit
HWS600
0
20
40
60
80
100
120
-10 0 10203040 506070 80
AmbientTemperature(℃)
Load(%)
MountingA,B
Ta(℃ Load(%)
Mounting(A) Mounting(B
-10to+50 100
+70 5 0
aHWS45
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 300, 600
5.WiringMethod
(1)Theoutputload lineandinput lineshallbe separatedto
improvenoisesensitivity.
(2)Thesensinglines shallbetwisted andseparatedfrom the
outputlinesforremotesensing.
(3)Usealllines asthickand shortaspossible tomakelower
impedance.
(4)Attachingacapacitor totheload terminalscaneliminate
noise.
(5)ForsafetyandEMIconsiderations,connect terminaltothe
mountingsetgroundterminal.
(6)Recommendedtorquefortheterminal;
HWS600Outputterminal(M5screw):2.50N·m(25.5kgf·
cm)
HWS300Input,Outputterminal&HWS600Inputterminal(M4
screw):1.27N·m(13.0kgf·cm)
AC(N)
AC(L)
AC(N)
AC(L)
AC(N)
AC(L)
AC(N)
AC(L)
Load
HWS300,600
Chassis
Circuit
Protector
NoiseFilter
[ThePHDconnectormanufacturemethod]
ThisproductisusingSPHD-001T-P0.5orSPHD-002T-0.5con-
nectormadefrom JAPANSOLDERLESSTERMINALMFG CO
LTD.
Regardingtomanufactureofaconnector,itbecomestheregula-
tionasfollowing.
a).AppricableWireandCrimpingtool
WiresizeisAWG#26-AWG#22andinsulationouterdiaisφ1.0-
φ1.5mm.
Appreciablewireper barrelsizeisUL1007 (standardwire)and
itsequivalentstandardwirecanbeused.
RegardingtheAWG#22,useUL1061oritsequivalentstandard
wire,becausewireinsulationouterdiameterofUL1061issamll.
Crimpingtoolisasbelow.
Crimpingtool Crimpingapplicator Dies
AP-K2orAP-KS
MKS-LS-10orMKS-L-10
SPHD-001-05/SPHD-002-05
b).CrimpingOperation
Thereferencevalue ofwirestripis 2.3mm.Aswirestrip length
differsdependingon typeofwire andcrimpingmethod,decide
thebestwirestriplengthconsideringprocessingcondition.When
wireisstripped,donotdamageorcutoffwireconductores.
Tableofcrimpheight
SPHD-001T-P0.5
Wire
InsulationO.D(mm)
Crimpheight(mm)
Type Size
Conductorpart
Insulationpart
UL1007 AWG#26 1.3
0.60
-
0.70
1.7
UL1007 AWG#24 1.5
0.65
-
0.75
1.8
UL1061 AWG#22 1.4
0.70
-
0.80
1.8
SPHD-002T-P0.5
Wire
InsulationO.D(mm)
Crimpheight(mm)
Type Size
Conductorpart
Insulationpart
UL1007 AWG#28 1.2
0.55
-
0.60
1.6
UL1007 AWG#26 1.3
0.60
-
0.65
1.7
UL1007 AWG#24 1.5
0.62
-
0.67
1.8
Note1.Crimp heightatwire barrelshouldbeset topre-deter-
mineddimensions.
Note2.Adjustcrimpheightatwireinsulationbarreltotheextent
thatwireinsulationisslightlypressed,andsetitsothat
crimpingisnotexcessivery.
Note
3.
Crimpingconditionatwireinsulationbarrelisasbelow
Fig.1. 
Note4.For AWG#28,#26,#24, useUL1007type.For AWG
#22,useUL1061type.
Fig.1
Good
Fig.2:Examplesofdefectivecrimping
Wire conductor protruding
length is long.
Wire conductor protruding
length is short.
Wire conductor
comes off.
Wire barrel bites wire
insulation.
Wire insulation is not
crimped sufficiently.
Checkofcrimping appearancevisuallyfor correctcrimpingas
referringtoaboveFig.2
Checkthetensile strengthatcrimped partwhenoperationfin-
ishes.
Tableoftensilestrengthatcrimpedpart.
SPHD-001T-P0.5
Wiresize RequirementNmin. ActualvalueN
UL1007AWG#26 20 39.2-45.1
UL1007AWG#24 30 68.6-74.5
UL1007AWG#22 40 92.1-96.0
SPHD-002T-P0.5
Wiresize RequirementNmin. ActualvalueN
UL1007AWG#28 15 27.0-34.3
UL1007AWG#26 20 44.1-48.0
UL1007AWG#24 30 66.6-71.5
c).Insertingcontactintohousing
Insertingcrimpedcontactintohousing
(1)Donotapplyanypullingforcetocrimpedpart,andinsert
contactparalleltohousing
(2)Insertcontactintohousingwithoutstoppingtoinnermost
(3)Checksecurelockingpereachinsertionbypullingwiresoftly
inordertocheckthatcontactdoesnotcomeoffhousing.Be-
sides,checkwhetherthereisthebacklashinthedirectionof
insertionaxis.
Defectexampleofslationinsertion
Cover of contacting part
Housing
lnsert with slanting
Cover of contacting part
Contact
d).MatingandUnmatingConnector
(1)Insertingconnector
Holdreceptaclehousingsecurelyandinsertintoheader
straightagainsttoheaderpostuntilclicksounds.
(2)Unmatingconnector
Holdallwiressecurelyandfixreceptaclehousingbyfingers
soastopry,andthen,withdrawitonthematingaxis.
Header
Hold all wiresFix receptacle housing
e).RoutingofWire
Routingwireso asnottoapplyexternal forcetoconnectorex-
ceptforcetosuchanextentthatwireslightlybuckles,consider-
inganenoughlengthtorouteandfixingofwire.
Morethan50mm
Airflow
BackSide
Fan Top
Morethan50mm
FrontSide
󱫄MountingMethod
(1)Forcedaircoolingtypepowersupply.
Thispowersupply hasventilatingholes onthefrontand
backsidepanels. Keepthesetwo areasfreelyasmuch as
possible.
(2)Themaximumallowablepenetrationis6mm.
Incompletethreadof mountingscrewshouldnot be
penetrated.
(3)Recommendedtorqueformountingscrew:
M4screw:1.27N·m(13.0kgf·cm)
aHWS46
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 300, 600
7.Fanlifeexpectancy
TheFan-lifehaslimitation.Therefore,periodicmaintenanceby
exchangingthelife-expiredfanisrequiredforthepowersupply.
Thefollowingfigureshowsthelifeoffan.
Fanexhausttemperature(℃)
Lifeexpectancy(year)
Measurementpointoffanexhausttemperature
Measuring point
Air Flow
P.S.
50mm
Thedifferencebetweentheintaketemperatureandtheexhaust
temperatureofthepowersupplyatIo=100%:
HWS300:4℃
HWS600:8℃
Nameoffanunitforreplacement
Applicablemodels
Appearance Pinassignments Price
󱫀 Fanunitforreplacement
Wehavepreparedanoptionalfanunitforreplacement.
Askusforreplacementofthefan.Thiswillbeachargedservice.Ifyouarereplacingthefanbyyourself,notethefollowing.
*1.Becarefulinhandlingthefanunitsoasnottocauseanimpactbydroppingitorhittingit,etc.
*2.Shutdowntheinputbeforestartingthereplacementoperation.
*3.Checkthattherearenoloosepartsinconnectorsorharnesstucking,etc.
*4.Safetystandards(UL,CE,etc.)arenotapplicable.
300-FAN-01
HWS300
ofstandard
specifications
Open
Housing PAP-03-V-S(J.S.T.)
Contact SPHD-001T-P0.5or
PSHD-002T-P0.5(J.S.T.)
Lengthoffanharness =55±10mm
PinNo. Description
1 Powersupply
2 Fanalarm
3 GND
Winddirection
600-FAN-01
HWS600
ofstandard
specifications
Open
Housing PAP-03-V-S(J.S.T.)
Contact SPHD-001T-P0.5or
PSHD-002T-P0.5(J.S.T.)
PinNo. Description
1 Powersupply
2 Fanalarm
3 GND
Winddirection
Beforeconcludingthattheunit isatfault,makethefollowing
checks.
(1)Checkiftheratedinputvoltageisconnected.
(2)Checkifthewiringofinputandoutputiscorrect.
(3)CheckiftheI/Oterminalconnectionisproperlytightenby
regulatedtorque.
(4)Checkifthewirethicknessisenough.
(5)Check iftheoutput voltagecontrol(V.adj) isproperly
adjusted.OVPmightbetriggedandoutputisshutdown.
(6)IfusefunctionoftheRemoteON/OFFcontrol,checkifthe
RemoteON/OFFcontrolconnectorisnotopened.
Ifinopencondition,powersupplywillnotoutput.
(7)Checkifthebuilt-inFANisnotstopped.IsFANstoppedby
somethingirregularsoretc?
IfFANstops,the PFsignalturnHighlevel andOTP
mightbeactivated.
(8)Powersupplyhas ventilatingholeson thefrontand back
panels.Checkifthereisanyirregularsordust,etc.
(9)Isthechassisofpowersupplyhotabnormally?Theoutput
isshutdownbyOTPoperation.
Pleasere-inputaftertheunittocooldownsufficiently.
(10)Checkif theoutputcurrent andoutputwattage doesnot
exceedspecification.
(11)Audiblenoisecanbeheardwheninputvoltagewaveform
isnotsinusoidal.
(12)Audiblenoisecanbeheardduringdynamicloadoperation.
8.Beforeconcludingthattheunitisatfault…
6.ExternalFuseRating
Refertothefollowingfuseratingwhenselectingtheexternal
fusesthataretobeusedoninputline.Surgecurrentflows
whenlineturnson. Use slow-blowor time-lagtypefuse, not
fast-blowfuse.Fuseratingisspecifiedbyin-rushcurrentvalue
atlineturn-on.Donotselectthefuseaccordingtoinputcur-
rent(RMS.)valuesundertheactualloadcondition.
HWS300:10A
HWS600:15A
9.Rangeoffreewarranty
Thisproductiswarrantedforaperiodof5yearsfromthedate
ofshipment.As forthebreakdown underanormaluse during
freewarranteeterm, repairisat freeofcharge.However, the
built-inFANmotorreplacementischarged.
PleasecontacttooursalesofficeforFANreplacement.
Conditionsofusage atthefree ofchargewarranteeare as
follows.
(1)Averageoperatingtemperature(ambienttemperatureofthe
powersupplyunit)isunder40ºC
(2)
Averageloadfactoris80%orless.
(3)Installationmethod :Standardinstallation. However,the
maximumratingiswithintheoutputderating.
Followingcasesarenotcoveredbywarranty.
(1)Improperusagelikedroppingproducts,applyingshockand
defectsfromoperationexceedingspecificationoftheunits.
(2)
Defectsresultingfromnaturaldisaster(fire,flood).
(3)Unauthorizedmodificationsorrepairbythebuyersdefects
notcausebyTDK-Lambda.
10.Option
Lengthoffanharness =710mm
aHWS47
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 1000
+:66HULHV,QVWUXFWLRQ0DQXDO
Besuretoreadthefollowingprecautionsthoroughlybeforeus-
ingthispowersupplyunit.
Payattentiontoallwarningsandcautionsbeforeusingtheunit.
Incorrectusagecouldleadtoanelectricshock,damagetothe
unitorafirehazard.
WARNING
●Donotmakeunauthorizedchangestopowersupplyunit,oth-
erwiseyoumayhaveelectricshockandvoidyourwarranty.
●Donottouchtheinternalcomponents;theymayhavehighvolt-
ageorhightemperature.Youmaygetelectricshockorburned.
●Whentheunitisoperating,keepyour handsandfaceaway
fromit;anaccidentmayinjureyou.
●Donotuseunitunderunusualconditionsuchasemissionof
smokeorabnormal smellandsoundetc. Itmightcause fire
andelectricshock.
Insuchcase,pleasecontactus;donotrepairbyyourself,as
itisdangerousfortheuser.
●Donotdroporinsertanythingintounit.Itmightcausefailure
andfire,whenusingtheunitundersuchcondition.
●Donotoperatetheseunitsattheconditionofcondensation.
Itmaycausefireandelectricshock.
●Powersupplieswithanoutputvoltageof48Vdcorlessmust
beearthedintheenduseequipmenttomaintainSELV.Ifthe
outputsarenotearthed,theymustbeconsideredhazardous
andmustnotbemadeuseraccessible.
●Powersupplies withanoutputvoltage of60Vdcare con-
sideredtobenon-SELV.Asaresultofthis,theoutputmust
beguardedoradeflectorfittedduringinstallationtoavoida
SERVICEENGINEERmaking inadvertentcontactwiththe
outputterminals,ordroppingatoolontothem.Theoutputof
thisproductmustnotbeconnectedtoaSELVcircuit.
Note:CEMARKING
●CEMarkingwhenappliedtoaproductcoveredbythishand-
bookindicatescompliance withthelowvoltage directive
(2006/95/EC)inthatitcomplieswithEN60950-1.
CAUTION
●Thispowersupplyisprimarilydesignedandmanufacturedto
useandencloseinotherequipment.
●Thispowersupplyunit hasabuilt-infan forair-cooling.Do
notblockairintakeandexhaust.Itmightcausefire.
●Inputvoltage,outputcurrent,outputpower,ambienttempera-
tureandambient humidityshouldbeused withinspecifica-
tions,otherwisetheunitwillbedamaged.
●The unitmightbe brokendownby accidentorunexpected
situation.Forapplicationequipment,whichrequiresveryhigh
reliability(nuclearrelated equipment,trafficcontrol equip-
ment,medicalequipment, etc.),pleaseprovide failsafety
functionintheequipment.
●Donotmakeanimproperwiringtoinputandoutputterminals.
Itmaycausedamage.
●Do notusein environmentsuchas strongelectromagnetic
field,erosivegas etc,orany environmentwhereconductive
foreignsubstancemayenter.
●Donotoperateandstorethisunitattheconditionofconden-
sation.Insuchcase,waterprooftreatmentisnecessary.
●Donotoperatethisunitafteritfallsdown.
●Theoutputvoltageofthispowersupplyunitisconsideredto
beahazardousenergylevel(Thevoltageis2Vormoreand
theelectricpoweris240VAormore),preventionfromdirect
contactwithvoltageoutputishighlynecessary.Whileinstall-
ingorservicing thispowersupply unit,avoiddroppingtools
bymistakeor directcontactwith voltageoutput.Thismight
causeanelectricalshock.
 Whilerepairingthispower supplyunit,the ACinputpower
mustbeswitch offandthe I/Oterminalvoltageshould be
lessthanthesafetylevel.
CAUTIONofIEC/EN/UL60601-1forHWS1000/ME
CAUTION
Theseproductsare designedforcontinuous operationwithinan
overallenclosure,and mustbemountedsuch thataccessto the
mainsterminalsisrestricted.See Clause16,IEC/EN/UL60601-
1.
●Theseproductsare NOTsuitablefor useinthepresence of
flammableanaestheticmixtures withairorwithoxygenor
withnitrousoxide.
●Connectonlyapparatuscomplying withIEC/EN/UL60601-1
tothesignalports.
●Exceptforpermanently installedequipmentas definedin
Clause57.6of IEC/EN/UL60601-1theoverall equipment
inwhichtheseproductsareinstalledmusthavedoublepole
fusingonthe inputmainssupply.The productsthemselves
havesinglepolefusingintheliveline.
●Theseproducts providebasicinsulation onlybetweenmains
andoutput,withreferencetoIEC/EN/UL60601-1.Suretoadd
supplementalinsulationtoinputoroutputintheequipment.
●Referenceshouldbemadetolocalregulationsconcerningthe
disposaloftheseproductsattheendoftheirusefullife.
●Themaximumnormal leakagecurrentof thisproductis500
microamperesforIEC/EN/UL60601-1. Whenusingitas a
patientcareequipment, alloutersurfaces oftheequipment
shallbeconstructed ofnonconductivematerial. SeeClause
19.5DV.2ofUL60601-1.
Theseproductshave notbeenassessed toIEC/EN60601-1-2
(EMC)butEMCtestdataisavailablefromTDK-Lambda.
BEFOREUSINGTHEPOWERSUPPLYUNIT
Pleasepayextraattentiontothewiring.Incorrectconnec-
tionwilldamagethepowersupply.
Whenconnectinginputandoutput wiring,inputAC-Line
shouldbeoff.
●Inputwiringandoutput wiringshallbe separated,otherwise
noisesusceptibilityofpowersupplyunitwillbeweak.
●The protectiveearth(PE) mustbeconnected totheinstru-
mentchassisandthechassisofthispowersupplyunit.
●Remotesensinglinesshallbetwistedorusetheshieldedwire.
●RemoteON/OFF controllinesshallbe twistedoruse the
shieldedwire.
1.TerminalExplanation
aHWS48
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 1000
󱫂CN01,CN02Connectorpinconfigurationandfunction
CN01,CN02pinconfigurationandfunctionarethesame.
Theyareconnectedtoeachotherinthispowersupplyunit.
WhenthepinofCN01sideisshortedthesamefunctionpinsofCN02sideareshorted.
PleasenotethatthefunctioncannotbeseparatelysetwithCN01andCN02.
Function
1+V
+S
-V
-S
PC
COM
PV
REF
CNT
TOG
PF
TOG
Connectedto+Outputterminalinthispowersupplyunit.
(+Vterminalcannotsupplyloadcurrent.)
Remotesensingterminalfor+Output
(Forremotesensingfunction,whichcompensatesforlinedropbetweenpowersupplyterminalsand
loadterminals.Connectto+Vterminalwhenremotesensingfunctionisunnecessary.)
Connectedto-Outputterminalinthispowersupplyunit.
(-Vterminalcannotsupplyloadcurrent.)
Remotesensingterminalfor-0utput
(Forremotesensingfunction,whichcompensatesforlinedropbetweenpowersupplyterminalsand
loadterminals.Connectto-Vterminalwhenremotesensingfunctionisunnecessary.)
Currentbalanceterminal
(Foroutputcurrentbalancinginparalleloperation.)
GroundforPCandPVsignal.
Outputvoltageexternalcontrolterminal
(Forpowersupplyoutputvoltagecontrolwithanexternalvoltage.ConnectitwiththeterminalREF
whenPVfunctionisunnecessary.)
ReferencevoltageterminalforOutputvoltagecontrol
(REFandPVareconnectedwhenshipping.)
RemoteON/OFFcontrolterminal
(WhentheCNTispulledtoTTLlow,thepowersupplyturnson.)
GroundforCNTandPFsignal.
Powerfailsignaloutputterminal.
(Astheoutputvoltagedrops,FANstopsandACinputvoltagedown,opencollectoroutput,
PowerFailsignalwilloutputHigh.)
GroundforCNTandPFsignal.
2
3
4
5
6
7
8
9
10
11
12
PinNo.
Configuration
1
3
5
7
9
11
4
2
6
8
10
12
1
3
5
7
9
11
4
2
6
8
10
12
CN01
CN02
13
24
13
24
Outputvoltage
detectioncircuit
OutputON/OFF
Controlcircuit
Powerfailsignal
generationcircuit
※OutputON/OFFcontrolcircuitandthePowerfailsignalcircuitareinsulated
withothercircuitsinthepowersupply.(InsulatingvoltageAC100V)
Outputcurrent
signalcircuit
Referencevoltage
generationcircuit
CN01
CN02
10 12
12
10
11
11
CN01,CN02areconnectedinthispowersupplyunitasfollows.
①+: +Outputterminal
②−: −Outputterminal
③ON: Output(PowerOn)indicationgreenLED(Theindicatorturnsonwhenthe
powersupplyoutputisinnormaloperatingcondition.)
④V.ADJ: Outputvoltageadjusttrimmer(The output voltageriseswhentrimmeris
turnedclockwise.)
⑤CN01: Remotesensing,ON/OFFcontrolsignal,Currentbalancesignal,
⑥CN02: OutputvoltageexternalcontrolsignalandPowerfailsignaloutputconnector.
⑦N: ACinputterminalN:Neutralline
⑧L: ACinputterminalL:LiveLine(Fuseinline)
⑨FG: FunctionGroundterminal(Frameground)
󱫀FrontPanelExplanation
1
8
2
5
6
3
4
7
9
NAMEPLATE
aHWS49
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
1357911
10 12
+ofload
-ofload
Twistwire
13579
2468
Red Black Brown Yellow
11
10 12
Attachedconnectorwhenshipping ConnectingcircuitwithCN01orCN02connector
󱫄
BasicConnection(Localsensing)
①Connect+Sterminalto+Vterminaland-Sterminalto
-Vterminalwithsensingwires.
②ConnectCNTterminaltoTOGterminalwithwire.
③ConnectPVterminaltoREFterminalwithwire.
※Pleaseuseattachmentconnectorforeachconnection.
※Inthefollowingcases,theoutputisshutdown.
WhenCNTandTOGisopened.
WhenPVandREFisopened.
󱫆Remotesensingrequired
①Connect+Sterminal to+ terminalofloadwith sensing
wire.
②Connect-Sterminal to- terminalofloadwith sensing
wires.
③ConnectCNTterminaltoTOGterminalwithwire.
④ConnectPVterminaltoREFterminalwithwire.
※Theaccuracyoftheoutputvoltagewilldeterioratewhenthe
sensingterminalsareopened.
※Inthefollowingcases,theoutputisshutdown.
WhenCNTandTOGisopened.
WhenPVandREFisopened.
NAME PLATE
Load
M8Boltsandnutsfor
connectingtotheload
line.
(Thesearenotattached
totheproduct.)
Connector:(JST)S12B-PHDSS
Attachedconnectorwhenshipping
・Housing:(JST)PHDR-12VS
・Contact:(JST)SPHD-001T-P0.5
12,34,78,910areshorted.
NAME PLATE
Load
M8Boltsandnutsfor
connectingtotheload
line.
(Thesearenotattached
totheproduct.)
Connector:(JST)S12B-PHDSS
Removestandardattachedconnector,anduse
theharnessmadebythecustomer.
・Housing:(JST)PHDR-12VS
・Contact:(JST)SPHD-001T-P0.5
2−+ofload,4-ofloadshouldbe
connected.
78,910:shouldbeshorted
Pleaseusewireforcontactandcrimping
toolspecifiedbymaker.
HWS 1000
aHWS50
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
󱫈
RemoteON/OFFcontrolrequired
①Removestandardattachedconnector,andusetheharness
madebythecustomerandconnectexternalsignaltobe-
tweenCNTandTOGterminal.
②TOGterminalisgroundforCNTterminal.
Incasethisfunctionisnotused,pleaseshortbetweenCNT
andTOGterminal.
󱫊PFsignaloutputrequired
①PFsignalisanopencollectoroutput,thereforePFsignal
outputsisshownincircuitbelow.
②TOGterminalisgroundforPFterminal.
ConnectingcircuitwithCN01orCN02connector ConnectingcircuitwithCN01orCN02connector
NAMEPLATE
M8Boltsandnutsfor
connectingtotheloadline
(Thesearenotattachedto
theproduct.)
Connector:(JST)S12B-PHDSS
Removestandardattachedconnector,and
usetheharnessmadebythecustomer.
・Housing:(JST)PHDR-12VS
・Contact:(JST)SPHD-001T-P0.5
1−2,3−4,7−8:shouldbeshorted
9:CNT
 ShouldbeconnectedtoON/OFFcontrolsignal.
10:TOG
 ShouldbeconnectedtoSignalGround.
*Pleaseusewireforcontactandcrimping
toolspecifiedbymaker.
Load
NAMEPLATE
M8Boltsandnutsfor
connectingtotheloadline
(Thesearenotattachedto
theproduct.)
Connector:(JST)S12B-PHDSS
Removestandardattachedconnector,anduse
theharnessmadebythecustomer.
・Housing:(JST)PHDR-12VS
・Contact:(JST)SPHD-001T-P0.5
1−2,3−4,7−8,9−10:shouldbeshorted.
11:PF
  ShouldbeconnectedtoPFsignaloutput
12:TOG
  ShouldbeconnectedtoSignalGround.
*Pleaseusewireforcontactandcrimpingtool
specifiedbymaker.
Load
57911
24 12
35 11
10 12
ON
10
PFsignaloutput
Tosignalground
HWS 1000
aHWS51
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
󱫀InputVoltageRange
Inputvoltagerangeis singlephase 85−265VAC(47−
63Hz).Inputvoltage,which isout ofspecification,may
causeunitdamage.Rated inputvoltage rangefixdur-
ingsafetystandardapplication isfrom100V to240VAC
(50/60Hz).
Whileapplyinginputvoltagefrom85VACto90VAC,out-
putloadcurrentderatingisrequired.
󱫂OutputVoltageRange
Outputvoltageissettotheratedvalueatshipping.V.ADJ
trimmeronthefrontpanelsideisusetoadjusttheoutput
voltagewithintherangespecified.Output voltagetrim-
mingrangeiswithin -20%−+20%of theratedoutput
voltage(48V,60Vmodel:-20%−+10%).Turnthetrimmer
clockwisetoincreaseoutputvoltage.Takenotewhenthe
outputvoltageisincreased excessivelyover voltagepro-
tection(OVP)functionmaytriggerandoutputvoltagewill
shutdown.
Usetheoutputpowerofthepowersupplybelowtherated
outputpowervaluewhenyouraisetheoutputvoltage.
󱫄OverVoltageProtection(OVP)
TheOVPfunction(Invertershutdownmethod,manualre-
settype)isprovided. OVPfunction operateswithin125-
145%oftheratedDCoutputvoltagevalue(3-7Vmodel:
125-140%,36Vmodel: 125-138%,48V,60Vmod-
el:115-125%),andtheoutput willbe shutdownwhen
OVPfunctiontriggers.When OVPfunction operates,the
inputpoweriscutoffforafewminutes,andthenpoweris
re-inputorremoteON/OFFcontrolsignalshallbeinputfor
recoveryoftheoutput.OVPvalueisfixedandcannotbe
adjusted.
󱫆OverCurrentProtection(OCP)
TheOCPfunction(Constant currentlimiting, Timedelay
shutdowntype)isprovided. OCPfunction operateswhen
theoutputcurrentexceeds105%ofmaximumDCoutput
currentspecificationandthe overcurrent orshortcircuit
conditioncontinues5-secondor more,the outputwillbe
shutdown.Whenthe OCPis triggered,theinputpower
iscutoffforafewminutes,andthenpowerisre-inputor
remoteON/OFFcontrolsignalshouldbeinputforrecovery
oftheoutput.TheOCPsettingisfixedandnottobead-
justedexternally.
󱫈
OverTemperatureProtection(OTP)
Overtemperatureprotectionfunction (manualreset type)
isprovided.Whenambient orinternal temperaturerises
abnormally,OTPwillshutdowntheoutput.WhenOTPis
triggered,inputpoweriscutoffandallowsufficientcooling
toresettheOTPfunction.Thenpowerisre-inputorremote
ON/OFFcontrolsignalshouldbeinputforrecoveryofthe
output.
󱫊
LowOutputDetectionCircuit(PF)
Lowoutputvoltagedetection circuitis provided.Power
Failsignal(PFsignal)willoutputwhenoutputvoltagede-
creasebyeitherthedroporbrownoutoftheinputvoltage
orOCP,OVPand OTPfunction operation.PFsignalwill
turnHighlevel toindicate theabnormalstatusofthe
powersupplywhenthe outputvoltage decreaseto80%
oftheoutputvoltage settingvalue. However,thereisa
possibilitythatPFsignalmaynotoutputduringparallelop-
eration.ThePFsignal circuitis insulatedfromthepower
supplyinputandoutputcircuitanditisanopencollector.
TOGterminalisgroundforPFterminal.
WhentheBuilt-inFan Motorof thispowersupplyunit
stops,PFsignalwillturntoHandtheoutputpowerwill
shutdown.TheBuilt-in FanMotor isacomponentwith
lifetime.Werecommenda periodicreplacement. Please
contactoursalesoffice.Replacementisatcustomersex-
penses.
PF
TOG
Vcemax:30V
Icmax:20mA
󱫌
RemoteSensing(+S,-Sterminal)
Remotesensingfunctionis providedto compensatefor
voltagedropacrossthewiringfromthepowersupplyout-
putterminalstothe loadinput terminals.Connect+S
terminalto+terminaloftheloadand-Sterminalto-
terminaloftheloadwithsensingwires.Thetotallinevolt-
agedrop(+sidelineand-sideline)shallbelessthan0.3V.
Incasethatsensinglineistoolong,itisnecessarytoput
anelectrolyticcapacitoracrosstheloadterminals.
Pleasetakenotethattheelectrolyticcapacitorhasgener-
ationofheatetc.donebytheripplecurrentdependingon
connectedload.Therefore,theelectrolyticcapacitormust
havearipplecurrent allowancehigher thantheoutput
ripplecurrent.IfCN01(orCN02)isinuse,terminal+S,-S
forCN02(orCN01)mustbeinopencondition.
+S
−S
Whenthefunctionofremotesensingisnotinused,con-
nect+Sterminalto+Vterminal,and-Sterminalto-Vter-
minalbytheattachmentconnector.
Ifremotesensingterminals areopened, thestabilityand
theaccuracyoftheoutputdeteriorate.Therefore,terminal
+S,-Smustbeconnected.
󱫎RemoteON/OFFControl
RemoteON/OFFcontrolis provided.Output canbere-
motelyswitchONand OFFby usingCNTterminaland
TOGterminaleventhough inputis connected.Theout-
putisturnedto ONwhen TOGandCNTterminalsare
shortedandoutputisturnedtoOFFwhentheseterminals
areopened.Whenthefunctionisnotused,connectTOG
andCNTterminalswith shortpiece. Thestandardsfor
thisfunctionare asfollows.TOGterminalisgroundfor
CNTterminal.
Sinkcurrent:3.5mA
Relay
Transistor
TTL,
andetc.
CNT
TOG
TheModeofcontrol
CNTLevelforTOGTerminal Output Built-inFanMotor
ShortorL(0−0.8V) ON Rotate
OpenorH(2.4−12V) OFF Stop
2.FunctionsandPrecautions
HWS 1000
aHWS52
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
1)TTLcompatible.The maximuminputvoltageto CNTtermi-
nalis12V, andthemaximum allowablereversevoltageis
-1V.ThesinkcurrentofCNTterminalis3.5mA.
2)OutputON/OFFcontrolcanbeenablebyaswitch,relayor
atransistorON/OFF.WhenCNTterminal−TOGterminalis
shortedpowersupplyisturnON,andwhenCNTterminal−
TOGterminalisopenedpowersupplyisturnOFF. 
3)RemoteON/OFFcontrol circuitisisolated fromtheinput
andoutputcircuitofpowersupply.
Itispossibletouseitregardlessofthepositiveandnegative
ofthepowersupplyoutput.
PleasebeawarethatifCNTterminalandTOGterminalis
shortandinputvoltageisgraduallyincrease,thiswilltrig-
gerthelowoutputvoltagedetectorprotectioncircuitand
willresulttooutputvoltageshutdown.
When thelowoutputvoltagedetectorprotectioncircuitis
triggered,theinputpoweriscutoffforafewminutes,and
thenpowerisre-inputorremoteON/OFFcontrolsignal
shouldbeinputforrecoveryoftheoutput.
󱫐OutputRipple&Noise
Maximumripple&noise valuein specificationsis mea-
suredaccordingtomeasurement circuitspecified byJEI-
TA-RC9131A.WhenLoadlinesarelonger,ripple&noise
becomeslarger.Inthis case,electrolytic capacitor,film
capacitor,etc.mightbenecessarytouseacrosstheload
terminal.Theoutputripple &noise cannotbemeasured
accuratelyiftheprobe groundlead ofoscilloscopeistoo
long.
 R
C1
Load
+S
−S
150mm
Co-axialcable
1.5m50Ω Oscillo-
Scope
C2
R:50Ω
C1:4700pF
C2:100uF
C3:0.47uF
Bandwidth
100MHz
PowerSupplyUnit C3
󱫒SeriesOperation
Forseriesoperation,eithermethod(A)or(B)ispossible.
Theremightbea stepin therisewaveformduringseries
operation.
Load
Load
Powersupply
Powersupply
Powersupply
Method(A) Method(B)
(Note1)
Powersupply
Load
(Note1)Pleaseconnectadiodeforby-passwhenusingmethod
(A)oftheseriesoperation.
Pleaseusethediodewithratedforwardcurrentisequal
ormorethan loadcurrentand thattheratedmaximum
reversevoltageis higherthanoutput voltageforeach
powersupply.
󱫓ParallelOperation
Currentbalancingfunctionisprovided.Eitherofoperations
mode(A)or(B)ispossible.
(A)ToIncreasetheOutputCurrent
Currentbalancingfunctionactivates byconnecting
PC-to-PCterminalandCOM-to-COM terminal,and
outputcurrentofeach powersupply isequivalently
suppliedtoload.Wires toPC terminalsshallbeas
shortaspossible,samelengthandtwisted.
Thereisapossibility thatoutput couldbe unstable
causedbyexternalnoise. Forthis case,disconnect
COMterminalandconnect -Sterminal fromparallel
powersupplytoasinglepointontheload.Pleasere-
ferconnectionMethod(A)-2.
1)Adjusttheoutputvoltageofeachpowersupplyto
besamevaluewithin1%or100mV,whicheveris
smaller.
2)Usesamelengthand typeof wiresforallload
lines.
3)Maximum valueofoutputcurrentin parallelis up
to80%ofall paralleledmodels. Thepurposeof
thecurrentbalancingfunctionisthestaticpower-
up.Thereforetheoutput voltagemight decrease
accordingtotheconditionofdynamicload.There
mightbeastepintherisewaveformduringparal-
leloperation.
4)Upto5unitscanbeconnectedinparallel.
(B)ToUseasaBackupPowerSupply
1)Setpowersupplyoutputvoltagehigherbythefor-
wardvoltagedropofdiode.
2)Adjusttheoutputvoltageofeachpowersupplyto
besamevalue.
3)Usewithinthespecificationsforoutputvoltageand
outputpower.
Method(A)-1
PC
PC
Load
PowerSupply
COM
COM
Method(B)
PowerSupply
Load
Io
Vf
Vf
Vo
Vo+Vf
Vo+Vf
OutputPower(W)=(Vo+Vf)×Io
PC
+S
+S
-S
-S
Load
PowerSupply
COM
COM
Method(A)-2
PC
+S
-S
+S
-S
+S
-S
+S
-S
󱫔IsolationTest
IsolationresistancebetweenoutputandFG(chassis)shall
bemorethan100MΩat500VDCandbetweenoutputand
CNT・PFshallbemorethan10MΩat100VDC.Forsafety
operation,voltagesettingof DCisolation testermustbe
donebeforethetest.Ensurethatitisfullydischargedafter
thetest.
CNT TOG PF
PC
+S
−S
FG
AC(L)
AC(N)
CNT TOG PF
PC
+S
−S
FG
AC(L)
AC(N)
Output−FG(chassis)
500VDC100MΩormore
Output−CNT・PF
100VDC10MΩ
ormore
Isolation
tester
Isolation
tester
󱫕WithstandVoltage
Thisseriesisdesigned towithstand 3.0kVACbetween
inputandoutput,2.0kVAC betweeninput andFG(chas-
sis),500VAC(60Vmodel:651VAC)betweenoutputand
FG(chassis),and100VAC betweenoutput andCNT・PF
terminaleachfor1 minute.When testingwithstandvolt-
age,setcurrentlimit ofwithstand voltagetestequipment
at20mA.
(Output-FG(chassis):300mA(60Vmodel:390mA),Out
HWS 1000
aHWS53
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
put-CNT・PF:100mA).
Theappliedvoltagemustbegraduallyincreasedfromzero
totestingvalueand thengradually decreasedfor shut
down.Whentimerisused,thepowersupplymaybedam-
agedbyhighimpulse voltageat timerswitchonandoff.
Connectinputandoutputasfollows.Ifoutputisleftopen
duringtest,outputvoltagemightappearmomentarily.
Thisproducthavemonolithicceramiccapacitorinsecond-
arycircuittoframeground.
Someofthewithstand voltagetester maygeneratehigh
voltageatthematchingwithmonolithicceramiccapacitor
andmaycausetheunitdamage.
So,pleasecheckthewaveformoftestvoltage.
PC
−S
FG
CNT TOG
PC
−S
FG
PF
CNT TOG
PC
−S
FG
PF
InputFG(chassis)(solidline)
2kVAC1min.(20mA)
InputOutput(dottedline)
3kVAC1min.(20mA)
WithstandVoltageTester
WithstandVoltageTester
WithstandVoltageTester
OutputFG(chassis)
500VAC1min.(300mA)
(60Vmodel:651VAC1min(390mA)
+S
+S
+S
OutputCNT・PF
100VAC1min.(100mA)
CNT TOG PF
AC(L)
AC(N)
AC(L)
AC(N)
AC(L)
AC(N)
󱫖
OutputVoltageExternalControl(PV)
(A)ControlbyExternalVoltage
Outputvoltageexternalcontrolfunctionisprovided.Output
voltagecanbevaried byapplying anexternalvoltage
(1−6V)toPVterminalandCOMterminal.Noteifan
externalvoltageisnot applied,there willbenooutput.
Pleaseconsiderthefollowing characteristicsbelow when
operatingtheunit.
ConnectionMethod
Load
Power
Supply
1−6V
COM
+S
−S
PV
OutputVoltageLinearity
20%
30% 3VModel
Nominal
Output
Voltage
O
utput
PVVolta
g
e
(
NominalIn
p
utVolta
g
e
)
3-36VModel
120%
110%
1V 1.5V 5V 5.5V 6V
48V,60VModel
Note:Onlyasforthemodelof3Voutput,theoutputvolt-
ageisusedfrom30%to120%atthePVvoltageisfrom
1.5Vto6.0V
Note:Onlyas forthe modelof5-36Voutput,the output
voltageisusedfrom 20%to 120%atthePVvoltage is
from1Vto6.0V
Note:Onlyasforthemodelof48V,60Voutput,theout-
putvoltageisusedfrom20%to110%atthePVvoltage
isfrom1Vto5.5V.
OutputVoltageDerating
110%
100%
120%
90%
83%
20%
0
3-36VModel
30%
Output(V)
LoadCurrent
Operating
Area
Nomina
Output
Voltage
48V,60VModel
3VModel
Note:Onlyasforthetypeof48V,60Voutput,themaxi-
mumoutputvoltageisusedupto110%at90%loadcur-
rent.
(B)ControlbyExternalVariableResistor
PVterminalandCOMterminalusageis thesameas
explainedinsectioncontrolby externalvoltage.But
inthismethodvoltageforcontrolissuppliedthroughREF
terminal.Variableresistoris connectedbetween REFter-
minalandCOMterminal andthe middlepointofvariable
resistorisconnectedtoPVterminal.Pleaseusetheoutput
voltagewithin20%- 120%of ratedoutputvoltagevalue
(3Vmodel:30%-120%,48V,60Vmodel:20%-110%).
Wiresforcontrollines mustbe twistedwireorshielded
wire.Inaddition,maximum variablevoltage whencontrol
byexternalvariableresistorisratedoutputvoltage(100%).
Whenoutputvoltagemust beexternally controlto120%
ofratedoutputvoltage(110%for48V,60Vmodel),please
followthefollowingprocedure.
(1) PVterminalandREFterminalisshortbyusingstan-
dardconnectorsupplied.
(2) Setthepowersupplyoutputvoltageto maximum
valueoftheoutput voltagevariable rangementioned
inspecificationstandardby adjustingV.ADJ volume
atthefrontpanel.
(3) Removestandardconnectorafterinputiscutoff.
(4) Connectexternal variableresistor(50kΩ)between
REFterminalandCOMterminal.Thenconnectmiddle
pointofexternalvariable resistorto PVterminal.
(sensingcurrentis1.4mA)
Power
supply
Load
Sensingcurrent:1.4mA
Variableresistor
50kΩ
Connectionmethod
+S
VR1
−S
REF
PV
COM
Whenoutputvoltageisoverratedvalue,pleasemakesure
thatmaximumoutputpower isbelow ratedvalue. More-
over,whenoutputvoltage isbelow ratedvalue,please
makesurethatmaximum outputcurrent isbelowrated
value.
Pleaseconsiderthefollowingcharacteristicduringusage.
HWS 1000
aHWS54
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
120%ofmaximumsettingvalue
110%ofmaximumsettingvalue
Ratedoutputvoltage:
0
VariableresistorvalueforREF-PV(VR1)[Ω]
10000 20000 30000 40000 50000
120%
100%
80%
60%
40%
20%
0%
Output
voltage
*Adjustableoutputvoltagewithin20%(3Vmodel:30%)of
output(lessthan1VofPVvoltage)isproportionaltoPV
voltageandhasalinearcharacteristic.However,foroutput
voltagewithin10%ofoutput(aboutlessthan0.5VofPV
voltage),outputwillgointointermittentmodeandripple
voltagebecomeslarge,alsoirregularsound isrelease
fromthepowersupply.However,itisnotdamage.There
willalsobecasesofthepowersupplyshuttingdowntrig-
geredbyundervoltagelockout protectionfunction.With
outputshuttingdown, lowoutput detectionfunction(PF)
triggersthePFsignalandsetitto"H",and alsooutput
LEDisswitchoff.Undervoltagelockoutprotectionmode,
switchoffinputforafewminutesandthenswitchoninput
againforrecovery.Recoveryfromunder voltagelockout
isalsopossiblebyturningremoteON/OFFcontrolsignal
OFFandON.Undervoltagedetectionvalueusesanauto-
matictrackingmode,whichfollowstheoutputvoltageand
constantlycorrespondtothe70%-80%ofoutputvoltage
withaprotectionfunctionmode.Baseontheexplana-
tionabove,wewillkindlyexcludetheusageofadjustable
outputvoltagewithin20%oftheoutputvoltagefromthe
productwarranty.For applicationthatrequiresvariable
outputvoltagewithin20%ofoutputvoltage,pleasekindly
considertheabovecontentspriortooperation. Forappli-
cationthatrequiresoutputvoltagebelow20%,duetodif-
ferenttypeofapplicationfortheuser'ssystem,theremight
beasituation(behavior)differentfromtheonementioned
above.Thereforepleasecheckwiththeusersystem.
󱫗OutputPeakCurrent
Formodelwithoutput peakcurrent, pleasemeetthefol-
lowingcondition.
Reducepeakcurrentvalueaccordingtooutputderatingas
section4-1.
Theoutputisshut downby protectioncircuitwhenrated
currentandcontinuouspeakoutputtime(τ)exceedsrated
valueduringusage.
Whenprotectioncircuitis activated,input istemporarily
cutoffforafewminutesandthenpowerisre-inputorre-
moteON/OFFcontrolsignal shouldbe inputforrecovery
oftheoutput.
Inputvoltagerange :AC180V-265V
ContinuousPeakoutputtime(τ)
:Within10seconds
Peakoutputcurrent(Ip):
Withintheratedpeakoutputcurren
t
Duty :upto35%
Duty=  τ
×100(%)
Condition1
0A
Ip1
τ
T
aA
0A
Ip
τ
T
Condition2
Ip1
2
×
τ
+a
2
×(1−
τ
Irmsmax
 ̄ ̄ ̄ ̄ ̄ ̄ ̄
Ip2×τ
Irmsmax
 ̄ ̄
Ip,Ip1: Peakoutputcurrent(A)
Irms : Effectivecurrent(A)
τ : Peakcurrentpulsewidth(sec)
T : Cycle(sec)
Model Irmsmax
HWS1000-7 94.6A
HWS1000-12 59.1A
HWS1000-15 47.3A
HWS1000-24 34.6A
HWS1000-36 23.0A
HWS1000-48 17.2A
HWS1000-60 13.8A
HWS 1000
aHWS55
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
󱫀OutputDerating
Mountingdirectionsareasfollows.
Standardmountingmethodis(A).Methods(B),(C),(D),(G)
and(H)arealsopossible.
Mountingmethodsbesides(A),(B),(C),(D),(G)and(H)
(example:(E)and(F))areinhibited.
HWS1000OutputDerating
3,5V
Ta(℃)
6-60V
Ta(℃)
LOAD(%)
ABCDGH
−10-+35 −10-+35 100
40 50 100
71 71 50
100
80
60
40
20
0−10 20
()
Load(%)
40 50 60 71
0
3.5VModel
6,7,12,15,24,36,48,60VModel
MountingA,B,C,D,G,H
󱫂MountingMethodCaution
(1) ThisPowersupplyunitisaforcedair-coolingsystem
withabuilt-infan.
(2) Thispowersupplyhasventilatingholesonthefront
andbackpanels.
Keeptheseareasfreelymorethan100mmfromfront
sideandmorethan50mmfromrearside.
(3) Pleasenotethatventilationwillbeworsenedina
dustyenvironment.
(4) Built-infanislimitedlifepart,whichrequireperiodic
replacement.(Replacementwillbecharged).
(5) Theambienttemperatureofthispowersupplyisless
than50mmfromthecenterofafrontside.
(6) Themaximumallowablepenetrationofmounting
screwis6mm.
(7) Recommendedtorqueformountingscrew(M4)is
1.27Nm.
Morethan50mm Morethan100mm
(Front)
(Rear)
(Top:HWS1000)
Fanmotor
ON
CNO1
VADJ
H
CNO2
FG N〔AC〕L
ON
CNO1
VADJ
H
CNO2
FG N〔AC〕L
ON
CNO1
VADJ
H
CNO2
FG N〔AC〕L
ON
CNO1
VADJ
H
CNO2
FG N〔AC〕L
ON
CNO1
VADJ
H
CNO2
FG N〔AC〕L
ON
CNO1
VADJ
H
CNO2
FG
N〔AC〕L
3.MountingDirections
(A)Standard
Mounting (B) (C) (D)
(F)Inhibit(E)Inhibit
HWS 1000
(G) (H)
aHWS56
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
5.ExternalFuseRating
Refertothefollowingfuseratingwhenselectingtheexter-
nalfusesforinputline.Surgecurrentflowswhenlineturns
on.Useslow-blowfuseortime-lugfuse.Donotusefast-
blowfuse.Fuseratingisspecifiedbyin-rushcurrentvalue
atlineturn-on.Donotselectthefuseaccordingtoinput
current(rms.)valuesundertheactualloadcondition.
     HWS100020A
6.Troubleshooting
Beforeconcludingthattheunitisatfault,makethefollow-
ingchecks.
(1) Checkiftheratedinputvoltageisapply.
(2) Checkifthewiringofinputandoutputiscorrect.
(3) CheckiftheI/Oterminalconnectionisproperlytight-
enbyaregulatedtighteningtorque.
(4) Checkifthewirematerialisnottoothin.
(5) Checkiftheoutputvoltagecontrol(V.ADJ)isproperly
adjusted.OVPmightbetriggedandoutputiscutoff.
(6) Checkifthewiringof+Sand-Sterminaliscorrect.
Ifinopencondition,thestabilityandtheaccuracyofthe
outputdeteriorate.
(7) IfusefunctionoftheremoteON/OFFcontrol,check
iftheremoteON/OFFcontrolconnectorisnot
opened.
  Ifinopencondition,outputiscutoff.
(8) Checkifthebuilt-infanisnotstopped.Isfanstopped
bysomethingirregularsordust,etc.
  Iffanstops,thePFsignalisturnon.
  Moreover,theoutputisinterceptedwiththeprotection
circuitiffanstops.
  Fansarethelimitedlifeparts.
(9) Thispowersupplyhasventilatingholesonthefront
andbackpanels.Checkifthereisanyirregularsor
dust,etc.
(10)Isthemainbodyofthepowersupplyabnormallyhot?
  Pleaseturnontheinputagainafterallowingtheunit
tocooldownsufficiently.Theoutputshutdownby
overtemperatureprotectionfunction.
(11)Checkiftheoutputcurrentandoutputpowerisnot
appliedoverspecification.
(12)Checkiftheinputvoltagewaveissinusoidal.Ifthis
powersupplyunitisconnectedtoaUPS,inputvolt-
agewavemightnotbesinusoidal.Anaudiblenoise
isemmitedfromthepowersupplyunit.
(13)AudiblenoisecanbeheardduringDynamic-Loadop-
eration.
HWS 1000
4.WiringMethod
(1) Theoutputloadlineandinputlineshallbeseparated
andtwistedtoimprovenoisesensitivity.
(2) Thesensinglinesshallbetwistedorshieldwireand
separatedfromtheoutputlines.
(3) Usealllinesasthickandshortaspossibletomake
lowerimpedance.Wiresaretobetwistedoruse
shieldwiretoimprovenoisesensitivity.
(4) Attachingacapacitortotheloadterminalscanelimi-
natenoise.
(5) FGterminalofthispowersupplyisfunctionalearth-
ing.Forsafetypurposes,connectprotectiveearthing
terminaltothemountingsetgroundterminal.
(6) Recommendedtorquefortheterminalpiece:
Inputterminal(M4screw): 1.27N・m
Outputterminal(M8Bolt&Nut): 10.8Nm
(7) Recommendedwiring
Load
Circuit
Protector
NoiseFilter
HWS1000
AC(L)
AC(N)
AC(N) A C(N)
AC(L) AC(L) AC(L)
AC(N)
FG
Chassisoftheequipment
Recommendedcircuitprotector:AC250V20A
Recommendednoisefilter: RSEN-2020(TDK-Lambda)
(8) M4screwforoutputterminalmightdamagetheter-
minalsinnerthread.ThisismainlycausebytheM4
screwsunthreadsection.Therefore,pleaseselecta
washer,springwasher,etc.toavoidunthreadscrew
sectionfrompenetratingintooutputterminalinner
section.
Outputterminal
Unthreadsection
aHWS57
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
7.Warranty
Thisproductiswarrantedforaperiodof5yearsfromthe
dateofshipment.Asforthebreakdownunderanormal
useduringfreewarranteeterm,repairisatfreeofcharge.
However,theBuilt-inFanMotorreplacementisforafee.
Pleasecontactyournearestsalesofficeforreplacement.
TheFan-lifehaslimitation.Therefore,periodicmainte-
nancebyreplacingthelife-expiredfanisrequired.
Thefollowingfigureshowsthelifeoffan.
1
10
0 102030405060708090100
Fanexhausttemperature(℃)
7
5
3
2
Lifeexpectancy(years)
Lifeexpectancy
Fanexhausttemperature 45℃ 45,000hours
Fanexhausttemperature 80℃ 11,000hours
Airflow
P.S.
50mm
Mea
Measuringpointoffanexhausttemperature
Conditionsofusageatthefreeofchargewarranteeareas
follows.
(1) Averageoperatingtemperature(ambienttemperature
ofthepowersupplyunit)is40℃
(2) Averageloadfactoris80%orless
(3) Installationmethod:Standardinstallation.However,
themaximumratingiswithintheoutputderating.
Followingcasesarenotcoveredbywarranty.
(1) Improperusagelikedroppingproducts,applyingshock
anddefectsfromoperationexceedingspecificationof
theunits.
(2) Defectsresultingfromnaturaldisaster(fire,flood).
(3) Unauthorizedmodificationsorrepairbythebuyers.
(4) DefectsnotcausebyTDK-Lambda.
8.Option
HWS1000
HWS1500
HWS1800T
(ofstandard
specifications)
Housing=XHP-3
(J.S.T.)
Contact=SXH-001T-P0.6
(J.S.T.)
Lengthoffanharness=65 ± 10mm
PinNo. Description
1 Powersupply
2 Fanalarm
3 GND
󱫀Fanunitforreplacement
HWS 1000
Open
󱫂InsulationtubeforHWS1000
Thefollowinginsulationtubecanbecuseforoutputterminal.
TCV-2001(shinagawashoko)
Pleaseconfirmshapeandsizefrommanufacturercatalog.
Wehavepreparedanoptionalfanunitforreplacement.
Askusforreplacementofthefan.Thiswillbeachargedservice.Ifyouarereplacingthefanbyyourself,notethefollowing.
*1.Becarefulinhandlingthefanunitsoasnottocauseanimpactbydroppingitorhittingit,etc.
*2.Shutdowntheinputbeforestartingthereplacementoperation.
*3.Checkthattherearenoloosepartsinconnectorsorharnesstucking,etc.
*4.Safetystandards(UL,CE,etc.)arenotapplicable.
Nameoffanunitforreplacement
Applicablemodels
Appearance Pinassignments Price
1500-FAN-01
Exampleofuseforinsulationtube
Winddirection
aHWS58
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 1500
Pleasepayextraattentiontothewiring.Incorrectconnection
willdamagethepowersupply.
Whenconnectinginputandoutputwiring,inputAC-Line
shouldbeoff.
●Inputwiringandoutputwiringshallbeseparated,otherwise
noisesusceptibilityofpowersupplyunitwillbeweak.
The protectiveearth(PE) must beconnectedtothe
instrumentchassisandthechassisofthispowersupplyunit.
●Remotesensinglinesshallbetwistedorusetheshieldedwire.
●RemoteON/OFFcontrollines shallbetwistedorusethe
shieldedwire.
NAME PLATE
①+: +Outputterminal
②−: −Outputterminal
③ON: Output(PowerOn)indicationgreenLED
(Theindicatorturnsonwhenthepowersupplyoutputisinnormal
operatingcondition.)
④V.ADJ:Outputvoltageadjusttrimmer (Theoutputvoltage riseswhen
trimmeristurnedclockwise.)
⑤CN01:Remotesensing,ON/OFFcontrolsignal,Currentbalancesignal,
⑥CN02:OutputvoltageexternalcontrolsignalandPowerfailsignal
outputconnector.
⑦N: ACinputterminalN:Neutralline
⑧L: ACinputterminalL:LiveLine(Fuseinline)
⑨FG: FunctionGroundterminal (Frameground) 
+:66HULHV,QVWUXFWLRQ0DQXDO
1.TerminalExplanation
Besuretoreadthefollowingprecautionsthoroughlybeforeus-
ingthispowersupplyunit.
Payattentiontoallwarningsandcautionsbeforeusingtheunit.
Incorrectusagecouldleadtoanelectricshock,damagetothe
unitorafirehazard.
WARNING
Donotmakeunauthorizedchangestopowersupplyunit,
otherwiseyoumayhaveelectricshockandvoidyourwarranty.
Donottouchtheinternalcomponents;theymayhavehigh
voltageorhightemperature.You maygetelectricshock or
burned.
●Whentheunitisoperating,keepyourhandsandfaceaway
fromit;anaccidentmayinjureyou.
●Donotuseunitunderunusualconditionsuchasemissionof
smokeorabnormalsmellandsoundetc.Itmightcausefire
andelectricshock.
 Insuchcase,pleasecontactus;donotrepairbyyourself,as
itisdangerousfortheuser.
●Donotdroporinsertanythingintounit.Itmightcausefailure
andfire,whenusingtheunitundersuchcondition.
Donotoperatetheseunitsattheconditionofcondensation.
Itmaycausefireandelectricshock.
●Powersupplieswithanoutputvoltageof48Vdcorlessmust
beearthedintheenduseequipmenttomaintainSELV.Ifthe
outputsarenotearthed,theymustbeconsideredhazardous
andmustnotbemadeuseraccessible.
Power supplieswithanoutputvoltageof60Vdc are
consideredtobenon-SELV.As aresult ofthis,the output
mustbeguardedoradeflectorfittedduringinstallationtoavoid
aSERVICEENGINEERmaking inadvertent contactwiththe
output terminals,ordroppingatoolontothem. Theoutputof
thisproductmustnotbeconnectedtoaSELVcircuit.
Note:CEMARKING
CEMarkingwhenappliedtoaproductcoveredbythis
handbookindicatescompliancewiththelowvoltagedirective
(2006/95/EC)inthatitcomplieswithEN60950-1.
CAUTION
●Thispowersupplyisprimarilydesignedandmanufacturedto
useandencloseinotherequipment.
Thispowersupplyunithasabuilt-infanforair-cooling.Do
notblockairintakeandexhaust.Itmightcausefire.
Inputvoltage,Outputcurrent,Outputpower,ambient
temperatureandambienthumidityshouldbeusedwithin
specifications,otherwisetheunitwillbedamaged.
Theunitmightbebrokendownbyaccidentorunexpected
situation.Forapplicationequipment,whichrequiresvery
highreliability(nuclearrelatedequipment,trafficcontrol
equipment,medicalequipment,etc.),pleaseprovidefail
safetyfunctionintheequipment.
Donotmakeanimproper wiringtoinputand output
terminals.Itmaycausedamage.
Donotuseinenvironmentsuchasstrongelectromagnetic
field,erosivegasetc,oranyenvironmentwhereconductive
foreignsubstancemayenter.
Donotoperateandstorethisunitattheconditionof
condensation.Insuchcase,waterprooftreatmentisnecessary.
●Donotoperatethisunitafteritfallsdown.
Theoutputvoltageofthispowersupplyunitisconsidered
tobe ahazardousenergylevel(Thevoltageis 2Vormore
andtheelectricpoweris240VAormore),preventionfrom
directcontactwithvoltageoutputishighlynecessary.While
installingorservicingthispower supplyunit,avoiddropping
toolsbymistakeordirectcontact withvoltageoutput. This
mightcauseanelectricshock.
 Whilerepairingthispower supplyunit,theAC inputpower
mustbeswitchoffandtheI/Oterminalvoltageshouldbe
lessthanthesafetylevel.
BEFOREUSINGTHEPOWERSUPPLYUNIT
󱫀FrontPanelExplanation
aHWS59
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
1
2
3
+ofoutput
−ofoutput
4
5
6
7
8
9
10
11
12
Red Black YellowBrown
CN01,CN02pinconfigurationandfunctionarethesame.
Theyareconnectedtoeachotherinthispowersupplyunit.
WhenthepinofCN01sideisshortedthesamefunctionpinsofCN02sideareshorted.
PleasenotethatthefunctioncannotbeseparatelysetwithCN01andCN02.
󱫂CN01,CN02ConnectorpinconfigurationandFunction
Attachedconnectorwhenshipping
1
2
3
4
Twistwire
5
6
7
8
9
10
11
12
Red Black YellowBrown
Connector:
(JST)S12B-PHDSS
Attachedconnector
whenshipping
・Housing:
(JST)PHDR-12VS
・Contact:
(JST)SPHD-001T-P0.5
12,34,78,910
areshorted.
Connector:
(JST)S12B-PHDSS
Attachedconnector
whenshipping
・Housing:
 (JST)PHDR-12VS
・Contact:
 (JST)SPHD-001T-P0.5
2+ofoutput,4-
ofoutputareconnected.
78,910areshorted
NAME PLATE
NAME PLATE
Load Load
M8Boltsandnutsfor
connectingtotheloadline.
(Thesearenotattachedto
theproduct.)
M8Boltsandnutsfor
connectingtotheloadline.
(Thesearenotattachedto
theproduct.)
 CN01,CN02areconnectedinthispowersupplyunitasfollows.
CN01
CN02
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
Outputvoltagedetectioncircuit
OutputON/OFFControlcircuit
Powerfailsignalgenerationcircuit
※OutputON/OFFcontrolcircuitandthePowerfailsignalcircuitareinsulated
 withothercircuitsinthepowersupply.(InsulatingvoltageAC100V)
Outputcurrentsignalcircuit
Referencevoltage
generationcircuit
CN01
1
3
5
7
9
11
2
4
6
8
10
12
1
3
5
7
9
11
2
4
6
8
10
12
CN02
PinNo.
Configuration Function
1 V Connectedto+ OutputterminalinthisPowersupplyunit.(+Vterminalcannotsupplyloadcurrent.)
2 S
Remotesensingterminalfor+output(Forremotesensingfunction,whichcompensatesforlinedropbetween
 powersupplyterminalsandloadterminals.Connectto+Vterminalwhenremotesensingfunctionisunnecessary
)
3 V Connectedto− OutputterminalinthisPowersupplyunit.(-Vterminalcannotsupplyloadcurrent)
4 S
Remotesensingterminalfor-output(Forremotesensingfunction,whichcompensatesforlinedropbetween
 powersupplyterminalsandloadterminals.Connectto-Vterminalwhenremotesensingfunctionisunnecessary)
5 PC Currentbalanceterminal(Foroutputcurrentbalancinginparalleloperation.)
6 COM GroundforPCandPVsignal.
7 PVOutputvoltageexternalcontrolterminal(Forpowersupplyoutputvoltagecontrolwithanexternalvoltage.
 ConnectitwiththeterminalREFwhenPVfunctionisunnecessary.)
8 REF ReferenceVoltageterminalforOutputvoltagecontrol(REFandPVareconnectedwhenshipping.)
9 CNT RemoteON/OFFcontrolterminal(WhentheCNTispulledtoTTLlow,thepowersupplyturnson.)
10 TOG GroundforCNTandPFsignal.
11 PF
Powerfailsignaloutputterminal.(Astheoutputvoltagedrops,FANstopsandACinputvoltagedown,open
 collectoroutput,PowerFailsignalwilloutputHigh.)
12 TOG GroundforCNTandPFsignal.
HWS 1500
󱫄BasicConnection(Localsensing)
3-7Vmodel
①Connect+Sterminalto+terminalofoutputand-S
terminalto-terminalofoutputwithsensingwires.
②ConnectCNTterminaltoTOGterminalwithwire.
③ConnectPVterminaltoREFterminalwithwire.
※Pleaseuseattachmentconnectorforeachconnection.
※Inthefollowingcases,theoutputisshutdown.
WhenCNTandTOGisopened.
WhenPVandREFis opened.
12-60Vmodel
①Connect+Sterminalto+Vterminaland-Sterminalto
-Vterminalwithsensingwires.
②ConnectCNTterminaltoTOGterminalwithwire.
③ConnectPVterminaltoREFterminalwithwire.
※Pleaseuseattachmentconnectorforeachconnection.
※Inthefollowingcases,theoutputisshutdown.
WhenCNTandTOGisopened.
WhenPVandREFisopened.
Attachedconnectorwhenshipping
aHWS60
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
󱫆Remotesensingrequired
①Connect+Sterminalto+terminalofloadwithsensingwire
②Connect-Sterminalto-terminalofloadwithsensingwires.
③ConnectCNTterminaltoTOGterminalwithwire.
④ConnectPVterminaltoREFterminalwithwire. 
※Theaccuracyoftheoutputvoltagewilldeterioratewhenthe
sensingterminalsareopened.
※Inthefollowingcases,theoutputisshutdown.
WhenCNTandTOGisopened.
WhenPVandREFisopened.
󱫈
RemoteON/OFFcontrolrequired
①Removestandardattached connector,andusetheharness
madebythecustomerand connectexternalsignal to
betweenCNTandTOGterminal.
②TOGterminalisgroundforCNTterminal.
In casethisfunctionisnotused,pleaseshortbetweenCNT
andTOGterminal.
󱫊PFsignaloutputrequired
①PFsignalisanopencollectoroutput,therefore
PFsignaloutputsisshownincircuitbelow.
②TOGterminalisgroundforPFterminal.
HWS 1500
Load
Connector:(JST)S12B-PHDSS
Removestandardattachedconnector,andusetheharnessmadeby
thecustomer.
・Housing:(JST)PHDR-12VS
・Contact:(JST)SPHD-001T-P0.5
(3-7Vmodel)2−+ofoutput,4−-ofoutput:shouldbeconnected
(12-60Vmodel)1−2,3−4:shouldbeshorted
7−8:shouldbeshorted
9:CNT
 ShouldbeconnectedtoON/OFFcontrolsignal.
10:TOG
 ShouldbeconnectedtoSignalGround.
*Pleaseusewireforcontactandcrimpingtoolspecifiedbymaker.
M8Boltsandnutsforconnecting
totheloadline
(Thesearenotattachedtothe
product.)
NAME PLATE
M8Boltsandnutsforconnecting
totheloadline
(Thesearenotattachedtothe
product.)
Load
Connector:(JST)S12B-PHDSS
Removestandardattachedconnector,andusetheharnessmade
bythecustomer.
・Housing:(JST)PHDR-12VS
・Contact:(JST)SPHD-001T-P0.5
(3-7Vmodel)2−+ofoutput,4−-ofoutput:shouldbeconnected
(12-60Vmodel)1−2,3−4:shouldbeshorted
7−8:shouldbeshorted
11:PF
  ShouldbeconnectedtoPFsignaloutput
12:TOG
  ShouldbeconnectedtoSignalGround.
*Pleaseusewireforcontactandcrimpingtoolspecifiedbymaker.
NAME PLATE
1
2
3
4
5
6
7
8
9
10
11
12
ON
ON
1
2
3
4
5
6
7
8
9
10
11
12
+ofoutput
−ofoutput
Load
Connector:
(JST)S12B-PHDSS
Removestandardattached
connector,andusetheharness
madebythecustomer.
Housing:
(JST)PHDR-12VS
Contact:
(JST)SPHD-001T-P0.5
2−+ofload,4-ofload
shouldbeconnected.
7−8,9−10shouldbeshorted
Pleaseusewireforcontact
andcrimpingtoolspecifiedby
maker.
M8Boltsandnuts
forconnectingto
theloadline.
(Thesearenotattached
totheproduct.)
NAME PLATE
1
2
3
+ofoutput
−ofoutput
4
5
6
7
8
9
10
11
12
Red Black YellowBrown
ConnectingcircuitwithCN01orCN02connector
●
ConnectingcircuitwithCN01orCN02connector
(3-7Vmodel)
(12-60Vmodel)
●
ConnectingcircuitwithCN01orCN02connector
(3-7Vmodel)
(12-60Vmodel)
1357 911
2468 1012
PFsignaloutput
Tosignalground
−ofoutput
+ofoutput
PFsignaloutput
Tosignalground
1357 911
2468 1012
aHWS61
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 1500
󱫀InputVoltageRange
Input voltagerangeissinglephase 85−265VAC(47−
63Hz).Inputvoltage,whichisoutofspecification,may
causeunitdamage.Ratedinputvoltagerangefixdur-
ingsafetystandardapplicationisfrom100Vto240VAC
(50/60Hz).
Whileapplyinginputvoltagefrom85VACto90VAC,out-
putloadcurrentderatingisrequired.
󱫂OutputVoltageRange
Outputvoltageissettotheratedvalueatshipping.V.ADJ
trimmeronthefrontpanelsideisusetoadjusttheoutput
voltagewithintherangespecified.Outputvoltagetrimming
rangeiswithin-20% +20%oftheratedoutputvolt-
age(48V,60VModel:-20% −+10%).Turnthetrimmer
clockwisetoincreaseoutputvoltage.Takenotewhenthe
outputvoltageisincreasedexcessivelyovervoltagepro-
tection(OVP)functionmaytriggerandoutputvoltagewill
shutdown.
Usetheoutputpowerofthepowersupplybelowtherated
outputpowervaluewhenyouraisetheoutputvoltage.
󱫄OverVoltageProtection(OVP)
TheOVPfunction(Invertershutdownmethod, manualreset
type)isprovided.OVPfunctionoperateswithin125-145%of
theratedDCoutputvoltagevaluevalue(3-7Vmodel:125-
140%,36Vtype:125-138%,48Vtype:115-135,60Vmodel:
115-125%),andtheoutputwillbeshutdownwhenOVPfunc-
tiontriggers. When OVPfunctionoperates,theinputpoweris
cutoforafewminutes,andthenpowerisre-inputorremote
ON/OFFcontrolsignalshallbeinputforrecoveryoftheoutput.
OVPvalueisfixedandcannotbeadjusted.
󱫆OverCurrentProtection(OCP)
TheOCP function(Constantcurrentlimiting,Timedelay
shutdowntype)isprovided.OCPfunctionoperateswhen
theoutputcurrentexceeds105%ofmaximumDCoutput
currentspecificationandtheovercurrentorshortcircuit
conditioncontinues 5-second or more,theoutput willbe
shutdown.WhentheOCPistriggered,theinputpower
iscutoforafewminutes,andthenpowerisre-inputor
remoteON/OFFcontrolsignalshould be inputforrecov-
eryoftheoutput.TheOCPsettingisfixedandnottobe
adjustedexternally.
󱫈
OverTemperatureProtection(OTP)
Overtemperatureprotectionfunction(manualresettype)
isprovided.Whenambientorinternaltemperaturerises
abnormally,OTPwillshutdowntheoutput.WhenOTPis
triggered,inputpoweriscutoffandallowsufficientcooling
toresettheOTP function.Thenpowerisre-inputorre-
moteON/OFFcontrolsignalshouldbeinputforrecovery
oftheoutput.
󱫊
LowOutputDetectionCircuit(PF
)
Lowoutputvoltagedetectioncircuitisprovided.Power
Failsignal(PFsignal)willoutputwhenoutputvoltagede-
creasebyeitherthedroporbrownoutoftheinputvoltage
orOCP,OVPandOTPfunctionoperation.PFsignalwill
turnHighleveltoindicatetheabnormalstatusofthe
powersupplywhentheoutputvoltagedecreaseto80%
oftheoutputvoltagesettingvalue.However,thereisa
possibilitythatPFsignalmaynotoutputduringparallelop-
eration.ThePFsignalcircuitisinsulatedfromthepower
supplyinputandoutputcircuitanditisanopencollector.
TOGterminalisgroundforPFterminal.
WhentheBuilt-inFanMotorofthispowersupplyunit
stops,PFsignalwillturntoHandtheoutputpowerwill
shutdown.TheBuilt-inFanMotorisacomponentwith
lifetime.Werecommendaperiodicreplacement.Please
contactoursalesoffice.Replacementisatcustomersex-
penses.
󱫌RemoteSensing(+S,-Sterminal)
Remotesensingfunctionis providedto compensatefor
voltagedropacrossthewiringfromthepowersupplyout-
putterminalstothe loadinput terminals.Connect+S
terminalto+terminaloftheloadand-Sterminalto-
terminaloftheloadwithsensingwires.Thetotallinevolt-
agedrop(+sidelineand-sideline)shallbelessthan0.3V.
Incasethatsensinglineistoolong,itisnecessarytoput
anelectrolyticcapacitoracrosstheloadterminals.
Pleasetakenotethat theelectrolytic capacitorhasgen-
erationofheatetc.donebytheripplecurrentdependingon
connectedload.Therefore,theelectrolyticcapacitormust
havearipplecurrent allowancehigher thentheoutput
ripplecurrent.IfCN01(orCN02)isinuse,terminal+S,-S
forCN02(orCN01)mustbeinopencondition.
+S
+
-
-
S
+
+
-
Whenthefunctionofremotesensingisnotinused,connect+S
terminalto+Vterminal,and‒Sterminalto‒Vterminalbytheat-
tachmentconnector.
Ifremotesensingterminalsareopened,thestabilityandtheac-
curacyoftheoutputdeteriorate.Therefore,terminal+S,-Smust
beconnected.
󱫎RemoteON/OFFControl
RemoteON/OFFcontrolis provided.Output canbere-
motelyswitchONand OFFby usingCNTterminaland
TOGterminaleventhough inputis connected.Theout-
putisturnedto ONwhen TOGandCNTterminalsare
shortedandoutputisturnedtoOFFwhentheseterminals
areopened.Whenthefunctionisnotused,connectTOG
andCNTterminalswith shortpiece. Thestandardsfor
thisfunctionare asfollows.TOGterminalisgroundfor
CNTterminal.
TOG
CNT
Sinkcurrent:3.5mA
Relay
Transistor
TTL,
andetc.
TheModeofcontrol
CNTLevelforTOGTerminal Output Built-inFanMotor
ShortorL(0−0.8V) ON Rotate
OpenorH(2.4−12V) OFF Stop
1) TTLcompatible.Themaximuminputvoltageto CNT
terminalis12V,and themaximum allowablereverse
voltageis-1V.The sinkcurrent ofCNTterminalis
3.5mA.
2)OutputON/OFFcontrolcanbeenable bya switch,
relayoratransistor ON/OFF.When CNTterminal−
TOGterminalisshortedpowersupplyisturnON,and
whenCNTterminal−TOGterminal isopened power
supplyisturnOFF.
3) RemoteON/OFFcontrolcircuitisisolatedfrom the
inputandoutputcircuitofpowersupply.
Itispossibleto useit regardlessofthepositiveand
negativeofthepowersupplyoutput.
2.FunctionsandPrecautions
TOG
PF
aHWS62
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 1500
Pleasebeawarethat ifCNT terminalandTOGterminal
isshortandinput voltageis graduallyincrease,thiswill
triggerthelowoutput voltagedetector protectioncircuit
andwillresulttooutputvoltageshutdown.
Whenthelowoutputvoltagedetectorprotectioncircuitis
triggered,theinputpoweriscutoffforafewminutes,and
thenpowerisre-input orremote ON/OFFcontrolsignal
shouldbeinputforrecoveryoftheoutput.
󱫐OutputRipple&Noise
Maximumripple&noise valuein specificationsismeasured
accordingtomeasurementcircuit specifiedby JEITA-
RC9131A.WhenLoadlines arelonger, ripple&noise
becomeslarger.Inthis case,electrolytic capacitor,film
capacitor,etc.mightbe necessaryto useacrosstheload
terminal.Theoutputripple &noise cannotbemeasured
accuratelyiftheprobegroundleadofoscilloscopeistoolong.
󱫒SeriesOperation
Forseriesoperation,eithermethod(A)or(B)ispossible.
Theremightbea stepin therisewaveformduringseries
operation.
Power
supply Load
Method(B)Method(A)
(Note1)
Load
+
-
Power
supply
+
-
Power
supply
+
-
+
-
Load
+
-
Power
supply
+
-
(Note1)
Pleaseconnectadiodeforby-passwhenusingmethod(A)
oftheseriesoperation.
Pleaseusethediodewithratedforward currentisequalor
morethanloadcurrentandthattheratedmaximumreverse
voltageishigherthanoutputvoltageforeachpowersupply.
󱫓ParallelOperation
Currentbalancingfunctionisprovided.Eitherofoperations
mode(A)or(B)ispossible.
(A)ToIncreasetheOutputCurrent
Currentbalancingfunctionactivates byconnecting
PC-to-PCterminalandCOM-to-COM terminal,and
outputcurrentofeach powersupply isequivalently
suppliedtoload.Wires toPC terminalsshallbeas
shortaspossible,samelengthandtwisted.
Thereisapossibility thatoutput couldbe unstable
causedbyexternalnoise. Forthis case,disconnect
COMterminalandconnect -Sterminal fromparallel
powersupplytoasinglepointontheload.Pleasere-
ferconnectionMethod(A)-2.
1) Adjusttheoutputvoltageofeachpower supplyto be
samevaluewithin1%or100mV,whicheverissmaller.
2) Usesamelengthandtypeofwiresforallloadlines.
3) Maximumvalue ofoutputcurrentinparallelisup to
80%ofallparalleledmodels.Thepurposeofthecurrent
balancingfunctionisthe staticpower-up. Therefore
theoutputvoltagemight decreaseaccording tothe
conditionofdynamicload.Theremightbeastepinthe
risewaveformduringparalleloperation.
4) Upto5unitscanbeconnectedinparallel.
(B)ToUseasaBackupPowerSupply
1) Setpowersupplyoutputvoltagehigherbythefor-
wardvoltagedropofdiode.
2) Adjusttheoutputvoltageofeachpowersupplyto
besamevalue.
3) Usewithin thespecificationsforoutputvoltage
andoutputpower.
(C)Inthecaseof parallelconnections, itispossibleto
controltheoutputvoltage byadjusting thevolume
fromonly1unit.Choose1unitthatwouldactasthe
masterandthisunit's volumewill determinetheout-
putvoltage.Thevolumeoneachslaveunitsmustbe
turnedclockwisetomaximum position.Then adjust
themastervolumetosettheoutputvoltage.
Connectionforthisapplicationisshowninfigure(c).
Load Load
Method(A)-1
Power
Supply
COM
PC
COM
PC
+
-
Power
Supply +
-
Method(A)-2
Power
Supply +
+S
-
-
S
+S
-
S
+S
-
S
Power
Supply
+
+S
-
-
S
COM
PC
COM
PC
󱫔IsolationTest
IsolationresistancebetweenoutputandFG(chassis)shall
bemorethan100MΩat500VDCandbetweenoutputand
CNT・PFshallbemorethan10MΩat100VDC.Forsafety
operation,voltagesettingof DCisolation testermustbe
donebeforethetest.Ensurethatitisfullydischargedafter
thetest.
+S
+
-
-
S
PC
CNT
TOG PF
FG
AC(L)
AC(N)
Isolationtester
+S
+
-
-
S
PC
CNT
TOG PF
FG
AC(L)
AC(N)
Isolationtester
OutputFG(chassis)
500VDC100MΩormore  
OutputCNT・PF
100VDC10MΩormore
Load Load
Method(B)
OutputPower(W)=(Vo+Vf)×Io
Power
Supply+
-
Power
Supply+
-
-
S
+S
-
S
+S
Vf Io
Vo+Vf Vo
Vo+Vf
Vf
Method(C)
Power
Supply
REF PV COM PC
REF PV COM PC
+
-
+
-
+
-
+S
++
-
S
-
Load
Co-axialcable
1.5m50Ω Oscillo-
Scope
R:50Ω
C1:4700pF
C2:100μF
C3:0.47μF
R
C1
C2 C3
Bandwidth
100MHz
PowerSupplyUnit
150mm
aHWS63
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
󱫕WithstandVoltage
Thisseriesisdesigned towithstand 3.0kVACbetweenin-
putandoutput,2.0kVAC betweeninput andFG(chassis),
500VAC(60Vmodel:651VAC)betweenoutputand FG
(chassis),and100VACbetween outputand CNT・PFtermi-
naleachfor1 minute.When testingwithstandvoltage,set
currentlimitofwithstandvoltagetestequipmentat20mA.
(Output-FG(chassis):300mA(60Vmodel:390mA),Out-
put-CNT・PF:100mA).
Theappliedvoltagemustbegraduallyincreasedfromzero
totestingvalueand thengradually decreasedfor shut
down.Whentimerisused,thepowersupplymaybedam-
agedbyhighimpulse voltageat timerswitchonandoff.
Connectinputandoutputasfollows.Ifoutputisleftopen
duringtest,outputvoltagemightappearmomentarily.
Thisproducthavemonolithic ceramiccapacitor in
secondarycircuittoframeground.
Someofthewithstand voltagetester maygeneratehigh
voltageatthematchingwithmonolithicceramiccapacitor
andmaycausetheunitdamage.
So,pleasecheckthewaveformoftestvoltage.
󱫖
OutputVoltageExternalControl(PV)
(A)ControlbyExternalVoltage
Outputvoltageexternalcontrol functionis provided.
Outputvoltagecanbevariedbyapplyinganexternal
voltage(1−6V)toPVterminal andCOMtermi-
nal.Noteifan externalvoltage isnotapplied,there
willbenooutput.Pleaseconsiderthefollowingchar-
acteristicsbelowwhenoperatingtheunit.
Note: Onlyasforthemodelof3Voutput,theoutputvoltage
isusedfrom30% to120% atthePVvoltageis from
1.5Vto6.0V
Note: Onlyasforthemodelof5-36Voutput,theoutputvoltage
isusedfrom20%to120%atthePVvoltageisfrom1V
to6.0V
Note: Onlyasforthe modelof 48V,60Voutput,the
outputvoltageisusedfrom20%to110%atthePV
voltageisfrom1Vto5.5V
Note: Onlyasforthe modelof 48V,60Voutput,the
maximumoutputvoltageis usedup to110%at90%
loadcurrent.
(B)ControlbyExternalVariableResistor
PVterminalandCOMterminalusageisthesame
asexplainedinsection「controlbyexternalvoltage」 .
Butinthismethod voltagefor controlissupplied
throughREFterminal.Variable resistoris connected
betweenREFterminaland COMterminal andthe
middlepointofvariable resistoris connectedto PV
terminal.Pleaseusethe outputvoltage within20%
-120%ofrated outputvoltage value(3Vmodel:
30%-120%,48V,60Vmodel:20%-110%).Wires
forcontrollinesmust betwisted wireorshieldwire.
Inaddition,maximumvariable voltagewhen control
byexternalvariableresistor israted outputvoltage
(100%).Whenoutputvoltagemustbeexternallycon-
trolto120%ofratedoutputvoltage(110%for48V,
60Vmodel),pleasefollowthefollowingprocedure.
(1) PV terminalandREF terminalisshortbyusing
standardconnectorsupplied.
(2) Setthepowersupply outputvoltage tomaximum
valueoftheoutput voltagevariable rangementioned
inspecificationstandardby adjustingV.ADJ volume
atthefrontpanel.
(3) Removestandardconnectorafterinputiscutoff.
(4) Connectexternalvariable resistor(50kΩ) between
REFterminalandCOMterminal.Thenconnectmiddle
pointofexternalvariable resistorto PVterminal.
(sensingcurrentis1.4mA)
Whenoutputvoltageis overrated value,please make
surethatmaximumoutput poweris belowratedvalue.
Moreover,whenoutputvoltage isbelow ratedvalue,
pleasemakesurethat maximumoutput currentisbelow
ratedvalue.
Pleaseconsiderthefollowingcharacteristicduringusage.
HWS 1500
+S
-
S
Load
Power
supply
VR1
PV
REF
COM
+
-
Sensingcurrent:1.4mA
Variableresistor50kΩ
Connectionmethod
PVVoltage(NominalInputVoltage)
Output
+S
-S
Load
Power
Supply
1−6V
PV
COM
+
-
Nominal
Output
Voltage
ConnectionMethod
OutputVoltageLinearity
3−36Vmodel
110%
120%
20%
30%
6V5.5V5V1V 1.5V
0
48V、60Vmodel
3Vmodel
Output
LoadCurrent
OperatingArea
Nominal
Output
Voltage
OutputVoltageDerating
110%
120%
20%
30%
0
83%90% 100%
48V、60Vmodel
3Vmodel
3−36Vmodel
+S
+
-
-S
PC
CNT
TOG PF
FG
AC(L)
AC(N)
+S
+
-
-S
PC
CNT
TOG PF
FG
AC(L)
AC(N)
Output−FG(chassis)
500VAC1min.(300mA)
(60Vmodel:651VAC1min(390mA)
+S
+
-
-S
PC
CNT
TOG PF
FG
AC(L)
AC(N)
Input−FG(chassis)(solidline)
2kVAC1min.(20mA)
Input−Output(dottedline)
3kVAC1min.(20mA)
Output−CNT・PF
100VAC1min.(100mA)
Withstand
VoltageTester
Withstand
VoltageTester
Withstand
VoltageTester
aHWS64
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 1500
󱫂MountingMethodCaution
⑴ThisPowersupplyunitisaforcedair-coolingsystemwitha
built-infan.
⑵Thispowersupplyhasventilatingholesonthefrontandback
panels.
 Keepthese areasfreelymore than100mmfrom frontside
andmorethan50mmfromrearside.
⑶Pleasenote thatventilationwill beworsenedin adustyenviron-
ment.
⑷Built-infanislimitedlifepart,whichrequireperiodicreplace-
ment.(Replacementwillbecharge).
⑸Theambient temperatureofthis powersupplyis lessthan
50mmfromthecenterofafrontside.
⑹Themaximumallowablepenetrationofmountingscrewis6mm.
⑺Recommendedtorqueformountingscrew(M4)is1.27N・m.
Morethan50mm
(Rear) (Front)
Morethan100mm
Fanmotor
(Top:HWS1500)
3.MountingDirections
󱫀OutputDerating
Mountingdirectionsareasfollows.
Standardmountingmethodis(A).Methods(B),(C)and(D)are
alsopossible.Mounting methodsbesides(A), (B),(C)and(D)
(example:(E)and(F))areinhibit.
HWS1500OutputDerating
3,5V
Ta(℃)
6-60V
Ta(℃)
LOAD(%)
ABCD
−10-+40 −10-+50 100 100 100 100
70 70 50 50 50 50
MountingA,B,C,D
100
80
60
40
20
0−10 20
AmbientTemperature(℃)
Load(%)
40 50 60 70
0
3.5VModel
6,7,12,15,24,36,48,60VModel
Standard
Mounting
(A) (B) (C)
Inhibit
(D) (E) Inhibit
(F)
*Adjustableoutputvoltage within20% (3Vmodel:30%)
ofoutput(lessthan1VofPVvoltage)isproportionaltoPV
voltageandhasalinearcharacteristic.However,foroutput
voltagewithin10%ofoutput(aboutlessthan0.5VofPV
voltage),outputwillgo intointermittent modeandripple
voltagebecomeslarge,alsoirregularsoundisreleasefrom
thepowersupply.However, itis notdamage.Therewill
alsobecasesofthepowersupplyshuttingdowntriggered
byundervoltagelockoutprotectionfunction.Withoutput
shuttingdown,low outputdetectionfunction(PF)triggers
thePFsignaland setit to"H",andalsooutput LEDis
switchoff.Undervoltagelockoutprotectionmode,switch
offinputforafewminutesandthenswitchoninputagain
forrecovery.Recoveryfromundervoltagelockoutisalso
possiblebyturningremote ON/OFFcontrol signalOFF
andON.Undervoltagedetectionvalueusesanautomatic
trackingmode,whichfollows theoutput voltageand
constantlycorrespondtothe 70%-80%of outputvoltage
withaprotectionfunction mode.Base ontheexplanation
above,wewillkindly excludethe usageofadjustable
outputvoltagewithin20% oftheoutputvoltagefrom the
productwarranty.Forapplication thatrequires variable
outputvoltagewithin20% of outputvoltage, please
kindlyconsidertheabove contentsprior tooperation.For
applicationthatrequiresoutput voltagebelow 20%, due
todifferenttypeofapplicationfortheuser'ssystem,there
mightbeasituation (behavior )differentfromtheone
mentionedabove.Thereforeplease checkwith theuser
system.
󱫗OutputPeakCurrent
Formodelwithoutput peakcurrent, pleasemeetthe
followingcondition.Reducepeakcurrent valueaccording
tooutputderatingassection4-1.
Theoutputisshut downby protectioncircuitwhenrated
currentandcontinuouspeak outputtime (τ)exceeds
ratedvalueduringusage.
Whenprotectioncircuitis activated,input istemporarily
cutofffora fewminutes andthenpowerisre-input or
remoteON/OFFcontrolsignalshouldbeinputforrecovery
oftheoutput.



a
Model
HWS1500-6
HWS1500-7
Irmsmax
177.5A
142.0A
HWS1500-24 62.1A
HWS1500-36 41.4A
HWS1500-60 24.8A
Irms max
Irms max
Irms
Condition1
Condition2
󱒖
󱒖󱒑 Peakoutputcurrent(A)
Effectivecurrent(A)
Peakcurrentpulsewidth(sec)
cycle(sec)
Inputvoltagerange:  AC180V-265V
ContinuousPeakoutputtime.( ):  Within10seconds
Peakoutputcurrent( ):
Withintheratedpeakoutputcurrent
Duty:upto35%
    
Duty= x100(%)
100%
120%
80%
60%
40%
20%
0% 10000 20000 30000 40000 500000
VariableresistorvalueforREF-PV(VR1)[Ω]
120%ofmaximumsettingvalue
110%ofmaximumsettingvalue
Ratedoutput:
voltage
Output
voltage
aHWS65
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 1500
5.ExternalFuseRating
Refertothe followingfuserating whenselectingtheexternal
fusesforinputline.Surgecurrentflowswhenlineturnson.Use
slow-blowfuseortime-lugfuse.Donotusefast-blowfuse.Fuse
ratingisspecifiedbyin-rushcurrentvalueatlineturn-on.Donot
selectthefuse accordingtoinput current(rms.)valuesunder
theactualloadcondition.
          HWS1500:30A
6.Troubleshooting
Beforeconcludingthat theunitis atfault,makethe following
checks.
(1)Checkiftheratedinputvoltageisapply.
(2)Checkifthewiringofinputandoutputiscorrect.
(3)CheckiftheI/Oterminalconnectionisproperlytightenbya
regulatedtighteningtorque.
(4)Checkifthewirematerialisnottoothin.
(5)Checkif theoutputvoltage control(V.ADJ)is properly
adjusted.OVPmightbetriggedandoutputiscutoff.
(6)Checkifthewiringof+Sand-Sterminaliscorrect.
Ifinopen condition,thestability andtheaccuracyof the
outputdeteriorate.
(7)Ifuse functionofthe remoteON/OFFcontrol,checkifthe
remoteON/OFFcontrolconnectorisnotopened.
Ifinopencondition,outputiscutoff.
(8)Checkif thebuilt-infan isnotstopped. Isfanstopped by
somethingirregularsordust,etc.
Iffanstops,thePFsignalisturnon.
Moreover,theoutput isinterceptedwith theprotection
circuitiffanstops.
Fansarethelimitedlifeparts.
(9)Thispower supplyhasventilating holesonthe frontand
backpanels.Checkifthereisanyirregularsordust,etc.
(10)Isthemainbodyofthepowersupplyabnormallyhot?
Pleaseturnon theinputagain afterallowingtheunit
tocooldown sufficiently.Theoutput shutdownbyover
temperatureprotectionfunction.
(11)Checkiftheoutputcurrentandoutputpowerisnotapplied
overspecification.
(12)Checkiftheinputvoltagewaveissinusoidal.Ifthispower
supplyunitis connectedtoa UPS,inputvoltagewave
mightnotbesinusoidal.Anaudiblenoiseisemmitedfrom
thepowersupplyunit.
(13)AudiblenoisecanbeheardduringDynamic-Loadoperation.
4.WiringMethod
⑴Theoutput loadlineand inputlineshall beseparatedand
twistedtoimprovenoisesensitivity.
⑵Thesensing linesshallbe twistedorshield wireandsepa-
ratedfromtheoutputlines.
⑶Usealllinesasthickandshortaspossibletomakelowerim-
pedance.Wiresaretobetwistedoruseshieldwiretoimprove
noisesensitivity.
⑷Attachinga capacitortothe loadterminalscan eliminate
noise.
⑸FGterminalofthispowersupplyisfunctionalearthing.
 Forsafety purposes,connectprotective earthingterminalto
themountingsetgroundterminal.
⑹Recommendedtorquefortheterminalpiece:
⑺Recommendedwiring
⑻M4screwforoutput terminalmightdamage theterminals
innerthread.ThisismainlycausebytheM4screw
sunthread
section.Therefore,pleaseselectawasher,springwasher,etc.
toavoidunthread screwsectionfrom penetratingintooutput
terminalinnersection.
AC(N)
AC(L)
AC(N)
AC(L)
AC(N)
AC(L)
AC(N)
AC(L)
FG
Load
HWS1500
Chassisof
theequipment  
Circuit
Protector
NoiseFilter
Inputterminal(M4screw):1.27N・m
Outputterminal(M8Bolt&Nut):10.8N・m
Outputterminal
Unthreadsection
aHWS66
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 1500
Askusforreplacementofthefan.Thiswillbeachargedservice.Ifyouarereplacingthefanbyyourself,notethefollowing.
*1.Becarefulinhandlingthefanunitsoasnottocauseanimpactbydroppingitorhittingit,etc.
*2.Shutdowntheinputbeforestartingthereplacementoperation.
*3.Checkthattherearenoloosepartsinconnectorsorharnesstucking,etc.
*4.Safetystandards(UL,CE,etc.)arenotapplicable.
Nameoffanunitforreplacement
Applicablemodels
Appearance Pinassignments Price
1500-FAN-01
HWS1000
HWS1500
HWS1800T
(ofstandard
specifications)
Winddirection
Open
Housing=XHP-3(J.S.T.)
Contact=SXH-001T-P0.6(J.S.T.)
Lengthoffanharness=65 ± 10mm
PinNo. Description
1 Powersupply
2 Fanalarm
3 GND
8.Option
Wehavepreparedanoptionalfanunitforreplacement.
󱫀Fanunitforreplacement
7.Warranty
Thisproductiswarrantedforaperiodof5yearsfromthe
dateofshipment.As forthe breakdownunderanormal
useduringfreewarranteeterm,repairisatfreeofcharge.
However,theBuilt-inFanMotorreplacementisforafee.
Pleasecontactyournearestsalesofficeforreplacement.
TheFan-lifehaslimitation.Therefore,periodicmaintenance
byreplacingthelife-expiredfanisrequired.
Thefollowingfigureshowsthelifeoffan.
Conditionsofusageatthefreeofchargewarranteeareas
follows.
⑴Averageoperating temperature(ambienttemperature ofthe
powersupplyunit)is40℃
⑵Averageloadfactoris80%orless
⑶Installationmethod: Standardinstallation.However, the
maximumratingiswithintheoutputderating.
Followingcasesarenotcoveredbywarranty.
⑴Improperusage likedroppingproducts, applyingshockand
defectsfromoperationexceedingspecificationoftheunits.
⑵Defectsresultingfromnaturaldisaster(fire,flood).
⑶Unauthorizedmodificationsorrepairbythebuyers.
⑷DefectsnotcausebyTDK-Lambda.
Air flow
Measuring point of fan exhaust temperature Measuring point
50mm
P.S.
10
7
5
3
2
105060708040 100
Lifeexpectancy(years)
Fanexhausttemperature(℃)
Lifeexpectancy Fanexhausttemperature45℃ 45,000hour
Fanexhausttemperature80℃ 11,000hour
󱫂InsulationtubeforHWS1500
Thefollowinginsulationtubecanbecuseforoutputterminal.
TCV-2001(shinagawashoko)
Pleaseconfirmshapeandsizefrommanufacturercatalog.
Exampleofuseforinsulationtube
aHWS67
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 1800T
+:676HULHV,QVWUXFWLRQ0DQXDO
1.TerminalExplanation
Besuretoreadthefollowingprecautionsthoroughlybeforeus-
ingthispowersupplyunit.
Payattentiontoallwarningsandcautionsbeforeusingtheunit.
Incorrectusagecouldleadtoanelectricalshock,damagetothe
unitorafirehazard.
WARNING
●Donotmakeunauthorizedchangestopowersupplyunit,oth-
erwiseyoumayhaveelectricshockandvoidyourwarranty.
●Donottouchtheinternal components;theymay havehigh
voltageorhightemperature.Youmaygetelectricalshockor
burned.
●Whentheunitisoperating,keepyour handsandfaceaway
fromit;anaccidentmayinjureyou.
●Donotuseunitunderunusualconditionsuchasemissionof
smokeorabnormal smellandsoundetc. Itmightcause fire
andelectricshock.
Insuchcase,pleasecontactus;donotrepairbyyourself,as
itisdangerousfortheuser.
●Donotdroporinsertanythingintounit.Itmightcausefailure
andfire,whenusingtheunitundersuchcondition.
●Donotoperatetheseunitsattheconditionofcondensation.
Itmaycausefireandelectricshock.
●Powersupplieswithanoutputvoltageof48Vdcorlessmust
beearthedintheenduseequipmenttomaintainSELV.
Iftheoutputsarenotearthed,theymustbeconsideredhaz-
ardousandmustnotbemadeuseraccessible.
●Powersupplies withanoutputvoltage of60Vdcare con-
sideredtobenon-SELV.Asaresultofthis,theoutputmust
beguardedoradeflectorfittedduringinstallationtoavoida
SERVICEENGINEERmaking inadvertentcontactwiththe
outputterminals,ordroppingatoolontothem.Theoutputof
thisproductmustnotbeconnectedtoaSELVcircuit.
Note:CEMARKING
●CEMarkingwhenappliedtoaproductcoveredbythishand-
bookindicatescompliancewiththelowvoltage
directive(2006/95/EC)inthatitcomplieswithEN60950-1.
CAUTION
●Thispowersupplyisprimarilydesignedandmanufacturedto
useandencloseinotherequipment.
●Thispowersupplyunit hasabuilt-infan forair-cooling.Do
notblockairintakeandexhaust.Itmightcausefire.
●Inputvoltage,Outputcurrent,Outputpower,ambienttemper-
atureandambienthumidityshouldbeusedwithinspecifica-
tions,otherwisetheunitwillbedamaged.
●The unitmightbe brokendownby accidentorunexpected
situation.Forapplicationequipment,whichrequiresveryhigh
reliability(nuclearrelated equipment,trafficcontrol equip-
ment,medicalequipment, etc.),pleaseprovide failsafety
functionintheequipment.
●Donotmakeanimproperwiringtoinputandoutputterminals.
Itmaycausedamage.
●Do notusein environmentsuchas strongelectromagnetic
field,erosivegas etc,orany environmentwhereconductive
foreignsubstancemayenter.
●Donotoperateandstorethisunitattheconditionofconden-
sation.Insuchcase,waterprooftreatmentisnecessary.
●Donotoperatethisunitafteritfallsdown.
●Theoutputvoltageofthispowersupplyunitisconsideredto
beahazardousenergylevel(Thevoltageis2Vormoreand
theelectricpoweris240VAormore),preventionfromdirect
contactwithvoltageoutputishighlynecessary.Whileinstall-
ingorservicing thispowersupply unit,avoiddroppingtools
bymistakeor directcontactwith voltageoutput.Thismight
causeanelectricalshock.
Whilerepairingthis powersupplyunit, theACinputpower
mustbeswitch offandthe I/Oterminalvoltageshould be
lessthanthesafetylevel.
BEFOREUSINGTHEPOWERSUPPLYUNIT
①+ :+Outputterminal
②− :−Outputterminal
③ON :Output(PowerOn)indicationgreenLED
(Theindicatorturnsonwhenthepowersupplyoutputisinnormaloper-
atingcondition.)
④V.ADJ :Outputvoltageadjusttrimmer
(Theoutputvoltageriseswhentrimmeristurnedclockwise.)
⑤CN01 :Remotesensing,ON/OFFcontrolsignal,Currentbalancesignal,
⑥CN02 :OutputvoltageexternalcontrolsignalandPowerfailsignaloutput
connector.
⑦FG :FunctionGroundterminal (Frameground)
⑧L1,L2,L3:ThreephaseACinputterminal (Fuseineachline)
Pleasepayextra attentiontothe wiring.Incorrectconnection
willdamagethepowersupply.
Whenconnectinginputandoutput wiring,inputAC-Line
shouldbeoff.
●Inputwiringandoutput wiringshallbe separated,otherwise
noisesusceptibilityofpowersupplyunitwillbeweak.
●The protectiveearth(PE) mustbeconnected totheinstru-
mentchassisandthechassisofthispowersupplyunit.
●Remotesensing linesshallbe twistedoruse theshielded
wire.
●RemoteON/OFF controllinesshallbe twistedoruse the
shieldedwire.
󱫀FrontPanelExplanation
1
8
2
5
6
3
4
7
FG L3 L2 L1
NAMEPLATE
HWS1800TFrontPanel
aHWS68
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
󱫂CN01,CN02Connectorpinconfigurationandfunction
Function
1+V
2+S
3−V
4−S
5PC
6 COM
7PV
8 REF
9 CNT
10 TOG
11 PF
12 TOG
Pin
No. Configuration
1
3
5
7
9
11
4
2
6
8
10
12
1
3
5
7
9
11
4
2
6
8
10
12
CN01
CN02
Remotesensingterminalfor+output
(Forremotesensingfunction,whichcompensatesforlinedropbetweenpowersupply
terminalsandloadterminals.Connectto+Vterminalwhenremotesensingfunctionis
unnecessary)
Remotesensingterminalfor-output
(Forremotesensingfunction,whichcompensatesforlinedropbetweenpowersupply
terminalsandloadterminals.Connectto-Vterminalwhenremotesensingfunctionis
unnecessary)
Outputvoltageexternalcontrolterminal
(Forpowersupplyoutputvoltagecontrolwithanexternalvoltage.Connectitwiththe
terminalREFwhenPVfunctionisunnecessary.)
Powerfailsignaloutputterminal.
(Astheoutputvoltagedrops,FANstopsandACinputvoltagedown,opencollector
output,PowerFailsignalwilloutputHigh.)
Connectedto+OutputterminalinthisPowersupplyunit.
(+Vterminalcannotsupplyloadcurrent.)
Connectedto-OutputterminalinthisPowersupplyunit.
(-Vterminalcannotsupplyloadcurrent)
GroundforPCand PVsignal.
GroundforCNTandPFsignal.
GroundforCNTandPFsignal.
Currentbalanceterminal
(Foroutputcurrentbalancinginparalleloperation.)
ReferenceVoltageterminalforOutputvoltagecontrol
(REFandPVareconnectedwhenshipping.)
RemoteON/OFFcontrolterminal
(WhentheCNTispulledtoTTLlow,thepowersupplyturnson.)
CN01


CN02


13579 11
2 4 6 8 10 12
13579 11
2 4 6 8 10 12
Outputvoltage
detectioncircuit
Outputcurrent
signalcircuit
Referencevoltage
generationcircuit
OutputON/OFF
Controlcircuit
Powerfailsignal
generationcircuit
※OutputON/OFFcontrolcircuitandthePowerfailsignalcircuitare
insulatedwithothercircuitsinthepowersupply.
(InsulatingvoltageAC100V)
CN01,CN02pinconfigurationandfunctionarethesame.
Theyareconnectedtoeachotherinthispowersupplyunit.
WhenthepinofCN01sideisshortedthesamefunctionpinsofCN02sideareshorted.
PleasenotethatthefunctioncannotbeseparatelysetwithCN01andCN02.
CN01、CN02areconnectedinthispowersupplyunitasfollows.
HWS 1800T
aHWS69
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
M8Boltsandnutsforconnecting
totheloadline.
(Thesearenotattachedtothe
product.)
・12-60Vmodel
①Connect+Sterminalto+Vterminaland-Sterminalto
-Vterminalwithsensingwires.
②ConnectCNTterminaltoTOGterminalwithwire.
③ConnectPVterminaltoREFterminalwithwire.
※Pleaseuseattachmentconnectorforeachconnection.
※Inthefollowingcases,theoutputisshutdown.
WhenCNTandTOGisopened.
WhenPVandREFisopened.
󱫄
Basic Connection (Localsens-
ing)
・3-7Vmodel
①Connect+Sterminalto+terminal ofoutputand-S
terminalto-terminalofoutputwithsensingwires.
②ConnectCNTterminaltoTOGterminalwithwire.
③ConnectPVterminaltoREFterminalwithwire.
※Pleaseuseattachmentconnectorforeachconnection.
※Inthefollowingcases,theoutputisshutdown.
WhenCNTandTOGisopened.
WhenPVandREFisopened.
FGL3L2L1
Load
+−
M8Boltsandnutsforconnecting
totheloadline.
(Thesearenotattachedtothe
product.)
Connector:(JST)S12B-PHDSS
Attachedconnectorwhenshipping
・Housing:(JST)PHDR-12VS
・Contact:(JST)SPHD-001T-P0.5
1−2,3−4,7−8,9−10areshorted.
Conn
Remo
custo
・Hou
・Con
2−
7−8
*Ple
NAMEPLATE
1357 911
2468 1012
Twistwire
Red Black Brown Yellow
Attachedconnectorwhenshipping
FGL3L2L1
Load
+ー
ting
e
M8Boltsandnutsforconnecting
totheloadline.
(Thesearenotattachedtothe
product.)
Connector:(JST)S12B-PHDSS
Removestandardattachedconnector,andusetheharnessmadebythe
customer.
・Housing:(JST)PHDR-12VS
・Contact:(JST)SPHD-001T-P0.5
2−+ofload,4−-ofloadshouldbeconnected.
7−8,9−10:shouldbeshorted
*Pleaseusewireforcontactandcrimpingtoolspectfiedbymaker.
NAMEPLATE
󱫆Remotesensingrequired
①Connect+Sterminalto+terminalofloadwithsensing
wire
②Connect-Sterminalto-terminal ofloadwith sensing
wires.
③ConnectCNTterminaltoTOGterminalwithwire.
④ConnectPVterminaltoREFterminalwithwire. 
※Theaccuracyoftheoutputvoltagewilldeterioratewhenthe
sensingterminalsareopened.
※Inthefollowingcases,theoutputisshutdown.
WhenCNTandTOGisopened.
WhenPVandREFisopened.
1357 911
2468 1012
−ofoutput
+ofoutput
Red Black Brown Yellow
Attachedconnectorwhenshipping
HWS 1800T
aHWS70
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
FGL3L2L1
Connector:(JST)S12B-PHDSS
Removestandardattachedconnector,andusetheharnessmade
bythecustomer.
・Housing:(JST)PHDR-12VS
・Contact:(JST)SPHD-001T-P0.5
(3-7Vmodel)2−+ofoutput,4−-ofoutput:shouldbeconnected
(12-60Vmodel)1−2,3−4:shouldbeshorted
7−8,9−10:shouldbeshorted.
11:PF
  ShouldbeconnectedtoPFsignaloutput
12:TOG
  ShouldbeconnectedtoSignalGround.
*Pleaseusewireforcontactandcrimpingtoolspectfiedbymaker.
NAMEPLATE
M8Boltsandnutsforconnecting
totheloadline.
(Thesearenotattachedtothe
product.)
Load
+ー
ConnectingcircuitwithCN01orCN02connector
󱫈
RemoteON/OFFcontrolrequired
①Remove standardattachedconnector, andusethe harness
madebythe customerandconnect externalsignaltobe-
tweenCNTandTOGterminal.
②TOGterminalisgroundforCNTterminal.
Incasethisfunctionisnotused,pleaseshortbetweenCNT
andTOGterminal.
FGL3L2L1
Connector:(JST)S12B-PHDSS
Removestandardattachedconnector,andusetheharnessmade
bythecustomer.
・Housing:(JST)PHDR-12VS
・Contact:(JST)SPHD-001T-P0.5
(3-7Vmodel)2−+ofoutput,4−-ofoutput:shouldbeconnected
(12-60Vmodel)1−2,3−4:shouldbeshorted
7−8:shouldbeshorted
9:CNT
   ShouldbeconnectedtoON/OFFcontrolsignal.
10:TOG
   ShouldbeconnectedtoSignalGround.
*Pleaseusewireforcontactandcrimpingtoolspectfiedbymaker.
NAMEPLATE
Load
+−
M8Boltsandnutsforconnecting
totheloadline.
(Thesearenotattachedtothe
product.)
ConnectingcircuitwithCN01orCN02connector
(3-7Vmodel)
(12-60Vmodel)
1357 911
2468 1012
ON
−ofoutput
+ofoutput
1357 911
2468 1012
ON
(3-7Vmodel)
1357 911
2468 1012
PFsignaloutput
Tosignalground
−ofoutput
+ofoutput
PFsignaloutput
Tosignalground
(12-60Vmodel)
1357 911
2468 1012
ConnectingcircuitwithCN01orCN02connector
1357 911
2468 1012
−ofload
+ofload
󱫊PFsignaloutputrequired
①PFsignal isanopen collectoroutput,thereforePF signal
outputsisshownincircuitbelow.
②TOGterminalisgroundforPFterminal.
HWS 1800T
aHWS71
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 1800T
󱫀InputVoltageRange
Inputvoltagerangeisthreephase170−265VAC(47−63Hz). Input
voltage,whichisoutofspecification,maycauseunitdamage.Rated
inputvoltagerangefixduringsafetystandardapplicationisfrom200V
to240VAC(50/60Hz).
󱫂OutputVoltageRange
Outputvoltageissettotheratedvalueatshipping.V.ADJtrimmeron
thefrontpanelsideisusetoadjusttheoutputvoltagewithintherange
specified.Outputvoltagetrimmingrangeiswithin-20% −+20%of
theratedoutputvoltage(48V,60Vmodel:-20% − +10%).Turnthe
trimmerclockwisetoincreaseoutputvoltage.Takenotewhenthe
outputvoltageisincreasedexcessivelyovervoltageprotection(OVP)
functionmaytriggerandoutputvoltagewillshutdown.
Usetheoutputpowerofthepowersupplybelowtherated output
powervaluewhenyouraisetheoutputvoltage.
󱫄OverVoltageProtection(OVP)
TheOVPfunction(Invertershutdownmethod,manualresettype)is
provided.OVPfunctionoperateswithin125-145%oftheratedDC
outputvoltagevalue(3-7Vmodel:125-140%,36Vmodel:125-138%,
48V,60Vmodel:115-125%),andtheoutputwillbeshutdownwhen
OVPfunctiontriggers.WhenOVPfunctionoperates,theinputpower
iscutoffforafewminutes,andthenpowerisre-inputorremoteON/
OFFcontrolsignalshallbeinputforrecoveryoftheoutput.OVPvalue
isfixedandcannotbeadjusted.
󱫆OverCurrentProtection(OCP)
TheOCPfunction(Constantcurrentlimiting,Timedelayshutdown
type)isprovided.OCPfunctionoperateswhentheoutputcurrent
exceeds105%ofmaximumDCoutputcurrentspecificationandthe
overcurrentorshortcircuitconditioncontinues5-secondormore,the
outputwillbeshutdown.WhentheOCPistriggered,theinputpower
iscutoffforafewminutes,andthenpowerisre-inputorremoteON/
OFFcontrolsignalshouldbeinputforrecoveryoftheoutput. The
OCPsettingisfixedandnottobeadjustedexternally.
󱫈
OverTemperatureProtection(OTP)
Overtemperatureprotectionfunction(manualresettype)isprovided.
Whenambientorinternaltemperaturerisesabnormally,OTPwillshut
downtheoutput.WhenOTPistriggered,inputpoweriscutoffandal-
lowsufficientcoolingtoresettheOTPfunction.Thenpowerisre-input
orremoteON/OFFcontrolsignalshouldbeinputforrecoveryof the
output.
󱫊
LowOutputDetectionCircuit(PF)
Lowoutputvoltagedetectioncircuitisprovided.PowerFailsignal(PF
signal)willoutputwhenoutputvoltagedecreasebyeitherthedropor
brownoutoftheinputvoltageorOCP,OVPandOTPfunctionopera-
tion.PFsignalwillturnHighleveltoindicatetheabnormalstatus
ofthepowersupplywhentheoutputvoltagedecreaseto80%ofthe
outputvoltagesettingvalue.However,thereisapossibilitythatPF
signalmaynotoutputduringparalleloperation.ThePFsignalcircuit
isinsulatedfromthepowersupplyinputandoutputcircuitanditisan
opencollector.TOGterminalisgroundforPFterminal.
WhentheBuilt-inFanMotorofthispowersupplyunitstops,PFsignal
willturntoHandtheoutputpowerwillshutdown.TheBuilt-inFan
Motorisacomponentwithlifetime.Werecommendaperiodicreplace-
ment.Pleasecontactoursalesoffice.Replacementisatcustomers
expenses.
Vcemax30V
Icmax20mA
PF
TOG
󱫌
RemoteSensing(+S,-Sterminal)
Remotesensingfunctionisprovidedtocompensateforvoltagedrop
acrossthewiringfromthepowersupplyoutputterminalstotheload
inputterminals.Connect+Sterminalto+terminaloftheloadand
-Sterminalto-terminaloftheloadwithsensingwires.Thetotal
linevoltagedrop(+sidelineand-sideline)shallbelessthan0.3V.In
casethatsensinglineistoolong,itisnecessarytoputanelectrolytic
capacitoracrosstheloadterminals.
Pleasetakenotethattheelectrolyticcapacitorhasgenerationofheat
etc.donebytheripplecurrentdependingonconnectedload.There-
fore,theelectrolyticcapacitormusthavearipplecurrentallowance
higherthentheoutputripplecurrent.IfCN01(orCN02)isinuse,ter-
minal+S,-SforCN02(orCN01)mustbeinopencondition.
+S
S
Whenthefunctionofremotesensingisnotinused,connect+Stermi-
nalto+Vterminal,and‒S terminalto‒Vterminalbytheattachment
connector.
Ifremotesensingterminalsareopened,thestabilityandtheaccuracy
oftheoutputdeteriorate.Therefore,terminal+S,-Smustbeconnect-
ed.
󱫎RemoteON/OFFControl
RemoteON/OFFcontrolisprovided.Outputcanberemotelyswitch
ONandOFFbyusingCNTterminalandTOGterminaleven though
inputisconnected.TheoutputisturnedtoONwhenTOG and CNT
terminalsareshortedandoutputisturnedtoOFFwhenthesetermi-
nalsareopened.Whenthefunctionisnotused,connectTOGand
CNTterminalswithshortpiece.Thestandardsforthisfunctionareas
follows.TOGterminalisgroundforCNTterminal.
2.FunctionsandPrecautions
aHWS72
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
TOG
Relay
Transistor
TTL,
andetc.
Sinkcurrent3.5mA
CNT
TheModeofcontrol
CNTLevelforTOGTerminal Output
Built-inFanMotor
ShortorL(0−0.8V) ON Rotate
OpenorH(2.4−12V) OFF Stop
1)TTLcompatible. Themaximuminput voltagetoCNTtermi-
nalis12V, andthemaximum allowablereversevoltageis
-1V.ThesinkcurrentofCNTterminalis3.5mA.
2)OutputON/OFFcontrolcanbeenablebyaswitch,relayor
atransistorON/OFF. WhenCNTterminal−TOGterminal is
shortedpowersupply isturnON, andwhenCNTterminal−
TOGterminalisopenedpowersupplyisturnOFF.
3)RemoteON/OFF controlcircuitis isolatedfromthe input
andoutputcircuitofpowersupply.
Itispossibletouseitregardlessofthepositiveandnegative
ofthepowersupplyoutput.
PleasebeawarethatifCNTterminalandTOGterminalisshort
andinputvoltageisgraduallyincrease,thiswilltriggerthelow
outputvoltagedetectorprotectioncircuitandwillresulttoout-
putvoltageshutdown.
Whenthelowoutputvoltagedetectorprotectioncircuitistrig-
gered,theinputpoweriscutoforafewminutes,andthen
powerisre-inputorremoteON/OFFcontrolsignalshouldbe
inputforrecoveryoftheoutput.
󱫐OutputRipple&Noise
Maximumripple&noisevalueinspecificationsismeasuredaccording
tomeasurementcircuitspecifiedbyJEITA-RC9131A.WhenLoadlines
arelonger,ripple&noisebecomeslarger.Inthiscase,electrolyticca-
pacitor,filmcapacitor,etc.mightbenecessarytouseacrosstheload
terminal.Theoutputripple&noisecannotbemeasuredaccuratelyif
theprobegroundleadofoscilloscopeistoolong.
C3
1.5m
R
C1
+S
C2
Co-axialcable
Power
Supply
Unit
Bandwidth
Oscillo-
Scope
Load
R:50Ω
C1:4700pF
C2:100uF,
C3:0.47uF
150mm
S
50Ω
100MHz
󱫒SeriesOperation
Forseriesoperation,eithermethod(A)or(B)ispossible.
Theremightbeastepintherisewaveformduringseriesoperation.




Method(B)
(Note1)
Powersupply
Powersupply Powersupply
Powersupply
Load
Load
Load
Method(A)
(Note1)Pleaseconnectadiodeforby-passwhenusingmethod
(A)ofthe seriesoperation.Pleaseuse thediodewith
ratedforwardcurrentisequalormorethanloadcurrent
andthatthe ratedmaximumreverse voltageishigher
thanoutputvoltageforeachpowersupply.
󱫓ParallelOperation
Currentbalancingfunctionisprovided.Eitherofoperationsmode(A)
or(B)ispossible.
(A)ToIncreasetheOutputCurrent
CurrentbalancingfunctionactivatesbyconnectingPC-to-
PCterminalandCOM-to-COMterminal,andoutputcurrentof
eachpowersupplyisequivalentlysuppliedtoload.WirestoPC
terminalsshallbeasshortaspossible,samelengthandtwisted.
Thereisapossibilitythatoutputcouldbeunstablecausedby
externalnoise.Forthiscase,disconnectCOMterminaland
connect-Sterminalfromparallelpowersupplytoasinglepoint
ontheload.PleasereferconnectionMethod(A)-2.
1)Adjusttheoutputvoltageofeachpowersupplytobesame
valuewithin1%or100mV,whicheverissmaller.
2) Usesamelengthandtypeofwiresforallloadlines.
3)Maximum value ofoutputcurrentinparallelisup
to80%ofallparalleledmodels.Thepurposeofthe
currentbalancingfunctionisthestaticpower-up.Therefore
theoutputvoltagemightdecreaseaccordingtothecondition
ofdynamicload.Theremightbeastepintherisewaveform
duringparalleloperation.
4) Upto5unitscanbeconnectedinparallel.
(B)ToUseasaBackupPowerSupply
1) Set powersupplyoutputvoltagehigherby theforward volt-
agedropofdiode.
2) Adjusttheoutputvoltageofeachpowersupplytobesamevalue.
3) Usewithinthespecificationsforoutputvoltageandoutputpower.
Method(A)-1
PC +S
-S
-S
PC
Load
PowerSupply
COM
COM
Method(B)
Power Suppl y
Load
Io
Vf
Vf
Vo
Vo+Vf
Vo+Vf
OutputPower(W)=(Vo+Vf)× Io
PC
+S
+S
-S
-S
PC
Load
Powe rSu pply
COM
COM
Method(A)-2
+S
-S
+S
-S
+S
󱫔IsolationTest
IsolationresistancebetweenoutputandFG(chassis)shallbemore
than100Ωat500VDCandbetweenoutputandCNT・PFshallbe
morethan10MΩat100VDC.Forsafetyoperation,voltagesettingof
DCisolationtestermustbedonebeforethetest.Ensurethatitisfully
dischargedafterthetest.
CNT TOG PF
PC
L1
FG
L2
L3
CNT TOG PF
OutputFG(chassis)
500VDC100M
Ω
ormore
OutputCNT-PF
100VDC10MΩ
ormore
Isolation
tester
Isolation
tester
+S
ーS
PC
L1
FG
L2
L3
+S
ーS
HWS 1800T
aHWS73
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
󱫕WithstandVoltage
Thisseriesisdesignedtowithstand3.0kVACbetweeninputandout-
put,2.0kVACbetweeninputandFG(chassis),500VAC(60Vmodel:
651VAC)betweenoutputandFG(chassis),and100VACbetween
outputandCNT・PFterminaleachfor1minute.Whentestingwith-
standvoltage,setcurrentlimitofwithstandvoltagetestequipmentat
20mA.
(Output-FG(chassis):300mA(60Vmodel:390mA),Output-CNT・PF
:100mA).
Theappliedvoltagemustbegraduallyincreasedfromzerototesting
valueandthengraduallydecreasedforshutdown.Whentimerisused,
thepowersupplymaybedamagedbyhighimpulsevoltageat timer
switchonandoff.Connectinputandoutputasfollows.Ifoutputisleft
openduringtest,outputvoltagemightappearmomentarily.
Thisproducthavemonolithicceramiccapacitorinsecondarycircuit
toframeground.
Someofthewithstandvoltagetestermaygeneratehighvoltageatthe
matchingwithmonolithicceramiccapacitorandmaycausetheunit
damage.
So,pleasecheckthewaveformoftestvoltage.
InputFG(chassis)(solidline)
  2kVAC1min.(20mA)
InputOutput(dottedline)
  3kVAC1min.(20mA)
OutputFG(chassis)
  500VAC1min.(300mA)
(60Vmodel:651VAC1min.(390mA)
Withstand
VoltageTester
Withstand
VoltageTester
Withstand
VoltageTester
OutputCNTPF
  100VAC1min.(100mA)
CNT TOG PF
PC
L1
FG
L2
L3
+S
ーS
CNT TOG PF
PC
L1
FG
L2
L3
+S
ーS
CNT TOG PF
PC
L1
FG
L2
L3
+S
ーS
󱫖
OutputVoltageExternalControl(PV)
(A)ControlbyExternalVoltage
 Outputvoltageexternalcontrolfunctionisprovided.Outputvoltage
canbevariedbyapplyinganexternalvoltage(1−6V)toPVterminal
andCOMterminal.Noteifanexternalvoltageisnotapplied,there
willbenooutput.Pleaseconsiderthefollowingcharacteristicsbelow
whenoperatingtheunit.
1ー6V
ConnectionMethod
Power
Supply
Load
+S
ーS
PV
COM
6V5.5V5V1V
01.5V
OutputVoltageLinearity
120%
110%
30%
20%
Nominal
Output
Voltage
PVVoltage(NominalInputVoltage)
Output
V
Note:Onlyasforthemodelof3Voutput,theoutputvoltageisusedfrom30%
to120%atthePVvoltageisfrom1.5Vto6V
Note:Onlyasforthemodelof5-36Voutput,theoutputvoltageisusedfrom
20%to120%atthePVvoltageisfrom1Vto6V
Note:Onlyasforthe model of48V,60Voutput,theoutputvoltage is used
from20%to110%atthePVvoltageisfrom1Vto5.5V
0
OutputVoltageDerating
120%
110%
30%
20%
83% 90% 100%
Nominal
Output
Voltage
Operating
Area
LoadCurrent
Output
V
Note:Onlyasforthemodelof48V,60Voutput,themaximumoutputvoltage
isusedupto110%at90%loadcurrent.
(B)ControlbyExternalVariableResistor
PVterminalandCOMterminalusageisthesameasexplained
insection「controlbyexternalvoltage」 .Butinthismethodvoltage for
controlissuppliedthroughREFterminal.Variableresistoriscon-
nectedbetweenREFterminalandCOMterminalandthemiddlepoint
ofvariableresistorisconnectedtoPVterminal.Pleaseusetheoutput
voltagewithin20%-120%ofratedoutputvoltagevalue(48V, 60V
model:20%-110%).Wiresforcontrollinesmustbetwistedwireor
shieldwire.Inaddition,maximumvariablevoltagewhencontrolby
externalvariableresistorisratedoutputvoltage(100%).Whenoutput
voltagemustbeexternallycontrolto120%ofratedoutputvoltage(110%
for48V,60Vmodel),pleasefollowthefollowingprocedure.
(1)PVterminalandREFterminalisshortbyusingstandardconnec-
torsupplied.
(2)Setthepowersupplyoutputvoltagetomaximumvalueoftheout-
putvoltagevariablerangementionedinspecificationstandardby
adjustingV.ADJvolumeatthefrontpanel.
(3)Removestandardconnectorafterinputiscutoff.
(4)Connectexternalvariableresistor(50kΩ)betweenREFterminal
andCOMterminal.Thenconnectmiddlepointofexternalvariable
resistortoPVterminal.(sensingcurrentis1.4mA)
VR1
COM
PV
+S
ーS
REF
Sensingcurrent:1.4mA
Variableresistor50kΩ
Connectionmethod
Power
supply
Load
Whenoutputvoltageisoverratedvalue,pleasemakesurethat
maximumoutputpowerisbelowratedvalue.Moreover,whenoutput
voltageisbelowratedvalue,pleasemakesurethatmaximumoutput
currentisbelowratedvalue.
Pleaseconsiderthefollowingcharacteristicduringusage.
HWS 1800T
aHWS74
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
Pleaseconsiderthefollowingcharacteristicduringusage.
120
100
80
60
40
20
0%
Ratedoutput
voltage
Output
voltage
120%ofmaximumsettingvalue
110%ofmaximumsettingvalue
010000 20000 30000 40000 50000
VariableresistorvalueforREF-PV(VR1)[Ω]
*Adjustableoutput voltagewithin20%(3Vmodel :30%)of
output(lessthan1VofPVvoltage)isproportionaltoPVvoltage
andhasa linearcharacteristic.However, foroutputvoltage
within10%of output(aboutless than0.5VofPV voltage),
outputwillgointointermittentmodeandripplevoltagebecomes
large,alsoirregular soundisrelease fromthepowersupply.
However,itis notdamage.There willalsobecases ofthe
powersupplyshutting downtriggeredbyunder voltagelock
outprotectionfunction. Withoutputshutting down,lowoutput
detectionfunction(PF) triggersthePF signalandsetit to
"H",andalsooutput LEDisswitchoff. Undervoltagelockout
protectionmode,switch offinputfor afewminutesand then
switchoninputagainforrecovery.Recoveryfromundervoltage
lockoutis alsopossibleby turningremoteON/OFFcontrol
signalOFFand ON.Undervoltagedetectionvalueusesan
automatictrackingmode,whichfollowstheoutputvoltageand
constantlycorrespondto the70%-80%ofoutput voltagewith
aprotectionfunction mode.Baseon theexplanationabove,
wewillkindly excludetheusage ofadjustableoutputvoltage
within20%oftheoutputvoltagefromtheproductwarranty.For
applicationthatrequires variableoutputvoltagewithin 20%of
outputvoltage,pleasekindlyconsider theabovecontentsprior
tooperation.Forapplicationthatrequiresoutputvoltagebelow
20%,duetodifferenttypeofapplicationfortheuser'ssystem,
theremightbe asituation( behavior)differentfrom theone
mentionedabove.Thereforepleasecheckwiththeusersystem.
󱫗OutputPeakCurrent
Formodelwithoutput peakcurrent, pleasemeetthefol-
lowingcondition.
Reducepeakcurrentvalueaccordingtooutputderatingas
section4-1.
Theoutputisshut downby protectioncircuitwhenrated
currentandcontinuouspeak outputtime (τ)exceeds
ratedvalueduringusage.
Whenprotectioncircuitis activated,input istemporarily
cutoffforafewminutesandthenpowerisre-inputorre-
moteON/OFFcontrolsignal shouldbe inputforrecovery
oftheoutput.
ContinuousPeakoutputtime.(τ):Within10seconds
Peakoutputcurrent(Ip):Withintheratedpeakoutputcurrent
Duty:upto35%
Duty=  τ
×100(%)
0A
Ip
1
T
aA
0A
I
p
T
Condition1 Condition2
ττ
Ip2×τ
Irmsmax   Ip12× τ
+a2×(1− τ
)
Irmsmax
 ̄ ̄
 ̄ ̄ ̄ ̄ ̄
 
Model Irmsmax
HWS1800T-6 177.5A
HWS1800T-7 142.0A
HWS1800T-12 88.7A
HWS1800T-15 71.0A
HWS1800T-24 62.1A
HWS1800T-36 41.4A
HWS1800T-48 31.0A
HWS1800T-60 24.8A
Ip,Ip1Peakoutputcurrent(A)
Iav Ratedoutputcurrent(A)
Im Averageoutputcurrent
(A)
τ Peakcurrentpulsewidth
(sec)
T cycle(sec)
󱫘InputOpenPhaseDetection
Ifoneofthe 3-phaseinput linebecomesopenorone
phasevoltagefallsbelow160VAC,theoutputwillbeshut
offinapproximately3 seconds.To restoretheoutputto
normal,shutoffthe inputonce, andapplyanormalinput
linevoltageagainafterforawhile.
HWS 1800T
aHWS75
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
1000
40
71
−10
Load (W)
MountingA,B,C,D
2005060
0
800
600
400
200
3.MountingDirections
󱫀OutputDerating
Mountingdirectionsareasfollows.
Standardmountingmethodis(A).Methods(B),(C)and(D)
arealsopossible.
Mountingmethodsbesides(A),(B),(C)and(D)(example:(E)
and(F))areinhibit.

(D) (F)Inhibit
(A)Standard
 Mounting
(B)(C)(E)Inhibit
HWS1800T3VOutputDerating
Ta(℃) LOAD(W)
ABCD
10−+ 40
990 990 990 990
50 825 825 825 825
60 660 660 660 660
71 495 495 495 495
HWS1800T5VOutputDerating
Ta(℃) LOAD(W)
ABCD
10−+ 40
1500 1500 1500 1500
50 1250 1250 1250 1250
60 1000 1000 1000 1000
71 750 750 750 750
HWS1800T6V-15VOutputDerating
Ta(℃) LOAD(W)
ABCD
10−+ 40
1500 1500 1500 1500
50 1500 1500 1500 1500
60 1125 1125 1125 1125
71 750 750 750 750
HWS1800T24V-60VOutputDerating
Ta(℃) LOAD(W)
ABCD
10−+ 40
1800 1800 1800 1800
50 1680 1680 1680 1680
60 1300 1300 1300 1300
71 900 900 900 900
󱫂MountingMethodCaution
(1)ThisPowersupplyunitisaforcedair-coolingsystem
withabuilt-infan.
(2)Thispowersupplyhas ventilatingholes onthefront
andbackpanels.
Keeptheseareasfreelymorethan100mmfromfront
sideandmorethan50mmfromrearside.
(3)Pleasenotethatventilation willbe worsenedina
dustyenvironment.
(4)Built-infanislimited lifepart, whichrequireperiodic
replacement.(Replacementwillbecharge).
(5)Theambienttemperatureofthispowersupplyisless
than50mmfromthecenterofafrontside.
(6)Themaximumallowablepenetration ofmounting
screwis6mm.
(7)Recommendedtorqueformounting screw(M4) is
1.27N・m.
71
Load (W)
40
−10 20
05060
MountingA,B,C,D
0
800
1000
1200
1400
1600
600
400
200
Load (W)
71
40
−10 20
05060
MountingA,B,C,D
0
800
1000
1200
1400
1600
600
400
200
MountingA,B,C,D
−10 71
2005060
Load (W)
40
0
800
1000
1200
1400
1600
1800
2000
600
400
200
More than50mm More than100m
m
(Rear)
Fan motor
(TopHWS1800T)
(Front)
HWS 1800T
aHWS76
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 1800T
4.WiringMethod
(1) Theoutputloadlineandinputlineshallbeseparated
andtwistedtoimprovenoisesensitivity.
(2)Thesensinglinesshallbetwistedorshieldwireand
separatedfromtheoutputlines.
(3)Usealllinesas thickand shortaspossibletomake
lowerimpedance.Wiresare tobe twistedoruse
shieldwiretoimprovenoisesensitivity.
(4)Attachingacapacitortotheloadterminalscanelimi-
natenoise.
(5)
FGterminalofthispowersupplyisfunctionalearthing.
Forsafetypurposes,connect protectiveearthing ter-
minaltothemountingsetgroundterminal.
(6)Recommendedtorquefortheterminalpiece:
Inputterminal(M4screw):1.27N・m
Outputterminal(M8Bolt&Nut):10.8N・m
(7)Recommendedwiring
L1
L3
FG
L2
L1
L3
L2
L1
L3
L2
L1
L3
L2
Input
Circuit
Protector
Noise Filter HWS1800T
Chassis of the equipment
Load
(8)M4screwforoutput terminalmight damagetheter-
minal'sinnerthread.ThisismainlycausebytheM4
screw'sunthreadsection.Therefore, pleaseselect a
washer,springwasher,etc. toavoid unthreadscrew
sectionfrom penetratinginto outputterminalinner
section.
5.ExternalFuseRating
Refertothefollowingfuseratingwhenselectingtheexter-
nalfusesforinputline.Surgecurrentflowswhenlineturns
on.Useslow-blowfuseortime-lugfuse.Donotusefast-
blowfuse.Fuseratingisspecifiedbyin-rushcurrentvalue
atlineturn-on.Do notselect thefuseaccordingtoinput
current(rms.)valuesundertheactualloadcondition.
HWS1800T:20A
Outputterminal
Unthreadsection
6.Troubleshooting
Beforeconcludingthattheunitisatfault,makethefollow-
ingchecks.
(1) Checkiftheratedinputvoltageisapply.
(2) Checkifthewiringofinputandoutputiscorrect.
(3) CheckiftheI/Oterminal connectionisproperly
tightenbyaregulatedtighteningtorque.
(4) Checkifthewirematerialisnottoothin.
(5) Checkiftheoutputvoltagecontrol(V.ADJ)isproperly
adjusted.OVPmightbetriggedandoutputiscutoff.
(6) Checkifthewiringof+Sand-Sterminalis
correct.Ifinopen condition,the stabilityandthe
accuracyoftheoutputdeteriorate.
(7) IfusefunctionoftheremoteON/OFFcontrol,checkif
theremoteON/OFFcontrolconnectorisnotopened.
Ifinopencondition,outputiscutoff.
(8) Checkifthebuilt-infanisnotstopped.Isfanstopped
bysomethingirregularsordust,etc.
Iffanstops,thePFsignalisturnon.
Moreover,theoutputisinterceptedwiththeprotection
circuitiffanstops.
Fansarethelimitedlifeparts.
(9) Thispowersupplyhasventilatingholeson thefront
andbackpanels.Check ifthere isany irregularsor
dust,etc.
(10)Isthemainbodyofthepowersupplyabnormallyhot?
Pleaseturnontheinputagainafterallowingtheunit
tocooldownsufficiently. Theoutput shutdownby
overtemperatureprotectionfunction.
(11)Checkif theoutput currentandoutputpowerisnot
appliedoverspecification.
(12)Checkif theinput voltagewaveissinusoidal.If
thispowersupplyunit isconnected toaUPS,input
voltagewavemightnot besinusoidal. Anaudible
noiseisemmitedfromthepowersupplyunit.
(13)Audiblenoise canbe heardduringDynamic-Load
operation.
aHWS77
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 1800T
7.Warranty
Thisproductiswarrantedforaperiodof5yearsfromthe
dateofshipment.As forthe breakdownunderanormal
useduringfreewarranteeterm,repairisatfreeofcharge.
However,theBuilt-inFanMotorreplacementisforafee.
Pleasecontactyournearestsalesofficeforreplacement.
TheFan-lifehaslimitation. Therefore,periodic mainte-
nancebyreplacingthelife-expiredfanisrequired.
Thefollowingfigureshowsthelifeoffan.
Life expectabcy
years
10
7
5
3
2
1
040 50 60 70 80 100
Fan exhaust temperature(℃
Lifeexpectancy
Fanexhausttemperature45℃ 45,000hour
Fanexhausttemperature80℃ 11,000hour
Airflow
P.S.
50mm
Measuringpoint
Measuringpointoffanexhausttemperature
Conditionsofusageatthefreeofchargewarranteeareas
follows.
(1)Averageoperatingtemperature(ambient temperature
ofthepowersupplyunit)is40℃
(2)Averageloadfactoris80%orless
(3)Installationmethod:Standardinstallation. However,
themaximumratingiswithintheoutputderating.
Followingcasesarenotcoveredbywarranty.
(1)Improperusagelikedroppingproducts,applyingshock
anddefectsfromoperationexceedingspecificationof
theunits.
(2) Defectsresultingfromnaturaldisaster(fire,flood).
(3) Unauthorizedmodificationsorrepairbythebuyers.
(4) DefectsnotcausebyTDK-Lambda.
8.Option
Wehavepreparedanoptionalfanunitforreplacement.
Askusforreplacementofthefan.Thiswillbeachargedservice.Ifyouarereplacingthefanbyyourself,notethefollowing.
*1.Becarefulinhandlingthefanunitsoasnottocauseanimpactbydroppingitorhittingit,etc.
*2.Shutdowntheinputbeforestartingthereplacementoperation.
*3.Checkthattherearenoloosepartsinconnectorsorharnesstucking,etc.
*4.Safetystandards(UL,CE,etc.)arenotapplicable.
Nameoffanunitforreplacement
Applicablemodels
Appearance Pinassignments Price
1500-FAN-01
HWS1000
HWS1500
HWS1800T
(ofstandard
specifications)
Winddirection
Open
Housing=XHP-3(J.S.T.)
Contact=SXH-001T-P0.6(J.S.T.)
Lengthoffanharness=65 ± 10mm
PinNo. Description
1 Powersupply
2 Fanalarm
3 GND
󱫀Fanunitforreplacement
󱫂InsulationtubeforHWS1800T
Thefollowinginsulationtubecanbecuseforoutputterminal.
TCV-2001(shinagawashoko)
Pleaseconfirmshapeandsizefrommanufacturercatalog.
Exampleofuseforinsulationtube
aHWS79
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
(*)(100Vin/200Vin)
HWS-P
SingleOutput
300W 600W
HWS300P−24
■Features
●Singleoutputpulsepowertypeinwiderangeinput
powersupply.
●Upto3timespeakcurrent.
FullLoad(100%)Capabilityat50operating
temperature
■ProductLineup
OutputVoltage
HWS300P HWS600P
Ave.Output
Current
PeakOutputCurrent Ave.Output
Current
PeakOutputCurrent
100Vin 200Vin 100Vin 200Vin
24V 12.5A 21.0A 42.0A 25.0A 40.5A 83.0A
36V 8.4A 14.0A 28.0A 16.7A 27.0A 55.5A
48V 6.3A 10.5A 21.0A 12.5A 20.0A 41.5A
■Applications
■Modelnamingmethod
Seriesname
OutputPower
ex.300P:300W,600P:600W
Nominaloutputvoltage
ex.24:24V,36:36V,48:48V
Thismeansthat,inconformitywithEUDirective2002/95/
EC,lead,cadmium,mercury, hexavalentchromium, and
specificbromine-basedflameretardants, PBBand PBDE,
havenotbeenused,exceptforexemptedapplications.
■
ConformitytoRoHSDirective
Y
E
A
R
S
warranty
5
UL60590-1/
CSA C22.2
No.60950-1
EN60950-1/
EN50178
aHWS80
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
ITEMS/UNITS LEDOM HWS300P-24 HWS300P-36 HWS300P-48
,QSXW
&'9UR&$99HJQD5HJDWOR9
]+\FQHXTHU)
3RZHU)DFWRU9$&7\S 

(IILFLHQF\9$&7\S  
(IILFLHQF\9$&7\S  
$S\7&$9WQHUUX&
,QUXVK&XUUHQW9$&7\S 
$
/HDNDJH&XUUHQW  P$ /HVVWKDQP$7\SDW9$&7\SDW9$&
2XWSXW
&'9HJDWOR9ODQLPR1
$WQHUUX&
HJDUHY$
0D[LPXP3HDN&XUUHQW9$&9$&
$
:UHZR3HJDUHY$
0D[LPXP3HDN3RZHU9$& 
:
0D[LPXP3HDN3RZHU9$& 
:
9PQRLWDOXJH5HQL/PXPL[D0
9PQRLWDOXJH5GDR/PXPL[D0
QDKWVVH/
WQHLFLIIHR&HUXWDUHSPH7 °&
0D[LPXP5LSSOH1RLVH7D°&  P9SS
0D[LPXP5LSSOH1RLVH7D°& P9SS
VPVPS\7HPL7SXGOR+
&'9HJQD5HOEDWVXMG$HJDWOR9
)XQFWLRQ
2YHU&XUUHQW3URWHFWLRQ9$& 
!!!$
2YHU&XUUHQW3URWHFWLRQ9$& 
!!!$
&'9QRLWFHWRU3HJDWOR9UHY2
5HPRWH6HQVLQJ
HOELVVR3ORUWQR&)
)212HWRPH5
3DUDOOHO2SHUDWLRQ
6HULHV2SHUDWLRQ 3RVVLEOH
WXSWX2URWFHOOR&QHS2)3ODQJL6JQLURWLQR0
\OQRHQL/&$9),0(6WHHPRWGHQJLV
H'3,'HQL/
(QYLURQ
PHQW
2SHUDWLQJ7HPSHUDWXUH  
6WRUDJH7HPSHUDWXUH 
2SHUDWLQJ+XPLGLW\ SRUGZHGR1+5
6WRUDJH+XPLGLW\ SRUGZHGR1+5
KFDHUXRK=<;WQDWVQR&ðVP
QLPURISHHZ6]+JQLWDUHSRRQW$QRLWDUEL9
ðVPQDKWVVH/HJDNFDSQ,NFRK6
&RROLQJ )RUFHG$LU%\%ORZHU)DQ
,VRODWLRQ
:LWKVWDQG9ROWDJH ,QSXW)*N9$&P$,QSXW2XWSXWN9$&P$
2XWSXW)*9$&P$2XWSXW&179$&P$IRUPLQ
,VRODWLRQ5HVLVWDQFH 0RUHWKDQ0Ω2XWSXW)*9'&
0RUHWKDQ0Ω2XWSXW&179'&DW°&DQG5+
6WDQ
GDUGV
6DIHW\6WDQGDUGV  $SSURYHGE\8/&6$(1(1
'HVLJQHGWRPHHW'(1$1
&(,WHHPRWGHQJLVH'&+)3
%,&&9%&&)%1(1(WHHPRWGHQJLVH'
,0(
,PPXQLW\
'HVLJQHGWRPHHW,(&/HYHO/HYHO/HYHO/HYHO/HYHO/HYHO
0HFKDQ
LFDO
JS\7WKJLH:
6L]H:×+×JQLZDU'HQLOWX2RWUHIH5[[PP'
5HDGLQVWUXFWLRQPDQXDOFDUHIXOO\EHIRUHXVLQJWKHSRZHUVXSSO\XQLW
 127(6
2SHUDWLQJWLPHDWSHDNRXWSXWLVOHVVWKDQVHFGXW\LVOHVVWKDQ)RUGHWDLOVUHIHUWRSHDNRXWSXWFRQGLWLRQ
:KHQWKHSHDNRXWSXWPRUHWKDQVHFLVFRQWLQXHGWKHRXWSXWLVVKXWGRZQPDQXDOUHVHW&17UHVHWRU5HSRZHURQ
$W9$&7D DQGDYHUDJHRXWSXWSRZHU
)RUFDVHVZKHUHFRQIRUPDQFHWRYDULRXVVDIHW\VSHFV8/&6$(1DUHUHTXLUHGWREHGHVFULEHGDV9$&+]
)LUVWLQUXVKFXUUHQW1RWDSSOLFDEOHIRUWKHLQUXVKFXUUHQWWR1RLVH)LOWHUIRUOHVVWKDQPV
0HDVXUHZLWK-(,7$5&$SUREH%DQGZLGWKRIVFRSH0+]$WDYHUDJHRXWSXWSRZHU
9$&FRQVWDQWORDG
1RORDG$YHUDJHORDGFRQVWDQWLQSXWYROWDJH
2&3FLUFXLWZLOOVKXWWKHRXWSXWGRZQPDQXDOUHVHW&17UHVHWRU5HSRZHURQ
293FLUFXLWZLOOVKXWWKHRXWSXWGRZQPDQXDOUHVHW&17UHVHWRU5HSRZHURQ
$W9$&QRPLQDORXWSXWYROWDJHDQGDYHUDJHRXWSXWFXUUHQW
0HDVXUHGE\WKHHDFKPHDVXULQJPHWKRGRI8/&6$(1DQG'(1$1DW+]7D 
5DWLQJV'HUDWLQJDWVWDQGDUGPRXQWLQJ5HIHUWRRXWSXWGHUDWLQJFXUYH
/RDGLVSHUFHQWRIDYHUDJHRXWSXWSRZHURUDYHUDJHRXWSXWFXUUHQWZKLFKHYHULVJUHDWHU
$VIRU'(1$1GHVLJQHGWRPHHWDW9$&
$W7D °&DQGDYHUDJHRXWSXWSRZHU
HWS300P
+:636SHFLILFDWLRQV
aHWS81
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS300P
+
-
-
+
V.ADJ
L
N
ON
CN1
BAR CODE
0$'(,1-$3$1
+:63
,13879$&$
2873879$
$PD[#3HDN3RZHU+]
$PD[#3HDN3RZHU
+:63
2873879$
$PD[3HDN3RZHU
#
1& 1&
72*
72* &17
3)
1&
1&
&1
3.NC
4.NC
2.NC
1.NC
5MAX
5.CNT
6.TOG
7.PF
8.TOG
2
8
4
6
1
3
7
5
FAN
3-M4
7.2(66.6)
64
10
11
60±0.540±0.510.5 11
1411(34.5)
10
(9.5)
82±1
(10.7)
7.3
25 105±0.5
25 120±0.5
22MAX
18MAX
165±1
(14.6)
(46.9)
61±1
(8.9)
SCREWPENETRATIONDEPTHMAX.6mm
8-M4TAPPEDHOLES(TAPPEDATTHEBOTTOMCHASSIS)
CN1PINASSIGN
NAMEPLATEDETAILS
WILLBE
MANUFACTURE
NAMEPLATE
4-M4
8-M4TAPPEDHOLES
SCREWPENETRATIONDEPTHMAX.6mm
SIGNALCONNECTOR
INFORMATION
COUNTRYOF
SHOWNHERE
AIRFLOW
S8B-PHDSS(JST)
2XWSXW'HUDWLQJ
3HDN2XWSXW&RQGLWRQ
2XWOLQH'UDZLQJ
SIGNAL CONNECTOR USED
PART DESCRIPTION PART NAME MANUFACT
PIN HEADER S8B-PHDSS J.S.T.
MATCHING HOUSINGS , PINS & TOOL
PART DESCRIPTION PART NAME MANUFACT
SOCKET HOUSING PHDR-08VS J.S.T.
TERMINAL PINS
SPHD-002T-P0.5(AWG28 24)
SPHD-001T-P0.5(AWG26 22)
J.S.T.
HAND CRIMPING TOOL
YRS-620(SPHD-002T-P0.5)
YC-610R(SPHD-001T-P0.5) J.S.T.
120
100
80
60
40
20
0
Ta(℃)
Ta(℃)
-10+50
70
100
50
-10 0 10 20 30 40 50 60 70 80
LOAD(%)
MOUNTINGA
(STANDARDMOUNTING)
MOUNTINGB DON'TUSE
LOAD(%)
MOUNTINGA MOUNTINGB
(*1)Load (%)ispercentofaverageoutputpowerorav erageoutputcurrent.
Forexample,load100%refers tofollowingconditionwhenoutputis24Vm odel.
 24[V],12.5[A]
(*2Peakoutputcurrentdoesnotneedderating.
Duty(%)
Peakoutputpower(W)
Peakoutputpowerv.s.Duty
300
50
45
40
35
30
25
20
15
10
5
0400 500 600 700 800 900 1000 1100
AC100V
AC200V
Use this product so that relationship among Duty, average output power (Wm)
and peak output power (Wp) satisfy conditions defined by expression below.
This product must be used less than average output power of specification (Wavg).
Also operating duration at peak output power should be less than 5 sec.
T
0(W)
Wp Wm
τ
WavgWm= T
Wp×τ
(%)100×
=Duty T
ττ≦5(sec
T
0(W)
a(W)
Wp
Wm
τ
Wavg≧Wm= +a
T
(Wp-a)×τ
Wp
Wavg
Wm
τ
:Peakoutputpower(W)
:Ratedaverageoutputpower(W)
:Averageoutputpower(W)
:Pulsewidthofpeakoutputpower(sec)
(Operatingtimeatpeakoutput)
T
Duty
:Period(sec)
:Thedutyispulsewidt
h
peakoutputpowerof
oneperiod(%)
aHWS82
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
ITEMS/UNITS LEDOM HWS600P-24 HWS600P-36 HWS600P-48
,QSXW
&'9UR&$99HJQD5HJDWOR9
]+\FQHXTHU)
3RZHU)DFWRU9$&7\S

(IILFLHQF\9$&7\S  
(IILFLHQF\9$&7\S  
$S\7&$9WQHUUX&
,QUXVK&XUUHQW9$&7\S 
$
&$9WDS\7&$9WDS\7QDKWVVH/$PWQHUUX&HJDNDH/
2XWSXW
&'9
HJDWOR9ODQLPR1
$WQHUUX&HJDUHY$
0D[LPXP3HDN&XUUHQW9$&9$&
$
:UHZR3HJDUHY$
0D[LPXP3HDN3RZHU9$& 
:
0D[LPXP3HDN3RZHU9$& 
:
9PQRLWDOXJH5HQL/PXPL[D0
9PQRLWDOXJH5GDR/PXPL[D0
QD
KWVVH/WQHLFLIIHR&HUXWDUHSPH7 °&
0D[LPXP5LSSOH1RLVH7D°&  P9SS
0D[LPXP5LSSOH1RLVH7D°& P9SS
VPVP
S\7HPL7SXGOR+
&'9HJQD5HOEDWVXMG$HJDWOR9
)XQFWLRQ
2YHU&XUUHQW3URWHFWLRQ9$& 
!!!$
2YHU&XUUHQW3URWHFWLRQ9$& 
!!!$
&'9QRLWFHWRU3HJDWOR9UHY2
5HPRWH6HQVLQJ
HOELVVR3ORUWQR&)
)212HWRPH5
[D0VWLQXHOELVVR3QRLWDUHS2OHOODUD3
6HULHV2SHUDWLRQ 3RVVLEOH
WXSWX2URWFHOOR&QHS2)3ODQJL6JQLURWLQR0
\
OQRHQL/&$9),0
(6WHHPRWGHQJLVH'3,'HQL/
(QYLURQ
PHQW
2SHUDWLQJ7HPSHUDWXUH  
6WRUDJH7HPSHUDWXUH 
2SHUDWLQJ+XPLGLW\ SRUGZHGR1+5
6WRUDJH+XPLGLW\ SRUGZHGR1
+5
KFDHUXRK=<;WQDWVQR&ðVPQLPURISHHZ6]+JQLWDUHSRRQW$QRLWDUEL9
ðVP
QDKWVVH/HJDNFDSQ,NFRK6
&RROLQJ )RUFHG$LU%\%ORZHU)DQ
,VRODWLRQ
:LWKVWDQG9ROWDJH ,QSXW)*N9$&P$,QSXW2XWSXWN9$&P$
2XWSXW)*9$&P$2XWSXW&179$&P$IRUPLQ
,VRODWLRQ5HVLVWDQFH 0RUHWKDQ0Ω2XWSXW)*9'&
0RUHWKDQ0Ω2XWSXW&179'&DW°&DQG5+
6WDQ
GDUGV
6DIHW\6WDQGDUGV  $SSURYHGE\8/&6$(1(1
'HVLJQHGWRPHHW'(1$1
&(,WHHPRWGHQJLVH'&+)3
%,&&9%&&
)%1(1(WHHPRWGHQJLVH',0(
,PPXQLW\
'HVLJQHGWRPHHW,(&/HYHO/HYHO/HYHO/HYHO/HYHO/HYHO
0HFKDQ
LFDO
JS\7WKJLH:
6L]H:×+×JQLZDU'HQLOWX2RWUHIH5[[PP'
5HDGLQVWUXFWLRQPDQXDOFDUHIXOO\EHIRUHXVLQJWKHSRZHUVXSSO\XQLW
 127(6
2SHUDWLQJWLPHDWSHDNRXWSXWLVOHVVWKDQVHFGXW\LVOHVVWKDQ)RUGHWDLOVUHIHUWRSHDNRXWSXWFRQGLWLRQ
:KHQWKHSHDNRXWSXWPRUHWKDQVHFLVFRQWLQXHGWKHRXWSXWLVVKXWGRZQPDQXDOUHVHW&17UHVHWRU5HSRZHURQ
$W9$&7D DQGDYHUDJHRXWSXWSRZHU
)RUFDVHVZKHUHFRQIRUPDQFHWRYDULRXVVDIHW\VSHFV8/&6$(1DUHUHTXLUHGWREHGHVFULEHGDV9$&+]
)LUVWLQUXVKFXUUHQW1RWDSSOLFDEOHIRUWKHLQUXVKFXUUHQWWR1RLVH)LOWHUIRUOHVVWKDQPV
0HDVXUHZLWK-(,7$5&$SUREH%DQGZLGWKRIVFRSH0+]$WDYHUDJHRXWSXWSRZHU
9$&FRQVWDQWORDG
1RORDG$YHUDJHORDGFRQVWDQWLQSXWYROWDJH
2&3FLUFXLWZLOOVKXWWKHRXWSXWGRZQPDQXDOUHVHW&17UHVHWRU5HSRZHURQ
293FLUFXLWZLOOVKXWWKHRXWSXWGRZQPDQXDOUHVHW&17UHVHWRU5HSRZHURQ
$W9$&QRPLQDORXWSXWYROWDJHDQGDYHUDJHRXWSXWFXUUHQW
0HDVXUHGE\WKHHDFKPHDVXULQJPHWKRGRI8/&6$(1DQG'(1$1DW+]7D 
5DWLQJV'HUDWLQJDWVWDQGDUGPRXQWLQJ5HIHUWRRXWSXWGHUDWLQJFXUYH
/RDGLVSHUFHQWRIDYHUDJHRXWSXWSRZHURUDYHUDJHRXWSXWFXUUHQWZKLFKHYHULVJUHDWHU
$VIRU'(1$1GHVLJQHGWRPHHWDW9$&
$W7D DQGDYHUDJHRXWSXWSRZHU
+:636SHFLILFDWLRQV
HWS600P
aHWS83
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS600P
++ --
6.TOG
5
7
7.PF
8.TOG
2.PC
1
3
4.NC
5.CNT
3.NC
1.COM
4
2
8
6
4-M5
V.ADJ
CN1
ON
N
L
40±0.5
82±1
(63.9)
(44.5)
(14.6)
32.1
21
60±0.520
5MAX
110±0.5
20
165±1
120±0.525
16
7. 2
10 10 (10)
3-M4(88.8)
100±1
(79.5)
17.5 16 (37.7)
18MAX
26MAX
8-M4TAPPEDHOLES
SCREWPENETRATIONDEPTHMAX.6mm
CN1PINASSIGN
NAMEPLATE
8-M4TAPPEDHOLES
SCREWPENETRATIONDEPTHMAX.6mm
SIGNALCONNECTOR
INFORMATION
NAMEPLATE AIRFLOW
S8B-PHDSS(JST)
2XWSXW'HUDWLQJ
3HDN2XWSXW&RQGLWRQ
2XWOLQH'UDZLQJ
SIGNAL CONNECTOR USED
PART DESCRIPTION
PART NAME
MANUFACT
PIN HEADER S8B-PHDSS J.S.T.
MATCHING HOUSINGS , PINS & TOOL
PART DESCRIPTION
PART NAME
MANUFACT
SOCKET HOUSING PHDR-08VS J.S.T.
TERMINAL PINS
SPHD-002T-P0.5(AWG28 24)
SPHD-001T-P0.5(AWG26 22)
J.S.T.
HAND CRIMPING
TOOL
YRS-620(SPHD-002T-P0.5)
YC-610R(SPHD-001T-P0.5)
J.S.T.
120
100
80
60
40
20
0
Ta(℃)
Ta(℃)
-10+50
70
100
50
-10 0 10 20 30 40 50 60 70 80
LOAD(%)
LOAD(%)
MOUNTINGA MOUNTINGB
(*1)Load (%)ispercentofaverageoutputpowerorav erageoutputcurrent.
Forexample,load100%refers tofollowingconditionwhenoutputis24Vm odel.
 24[V],12.5[A]
(*2Peakoutputcurrentdoesnotneedderating.
MOUNTINGA
(STANDARDMOUNTING)
MOUNTINGB DON'TUSE
Duty(%)
600
50
45
40
35
30
25
20
15
10
5
0
800 1000 1200 1400 1600 1800 2000
AC100V
AC200V
Peakoutputpower(W)
Peakoutputpowerv.s.Duty
Use this product so that relationship among Duty, average output power (Wm)
and peak output power (Wp) satisfy conditions defined by expression below.
This product must be used less than average output power of specification (Wavg).
Also operating duration at peak output power should be less than 5 sec.
T
0(W)
Wp Wm
τ
WavgWm= T
Wp×τ
(%)100×
=Duty T
ττ≦5(sec
T
0(W)
a(W)
Wp
Wm
τ
Wavg≧Wm= +a
T
(Wp-a)×τ
Wp
Wavg
Wm
τ
:Peakoutputpower(W)
:Ratedaverageoutputpower(W)
:Averageoutputpower(W)
:Pulsewidthofpeakoutputpower(sec)
(Operatingtimeatpeakoutput)
T
Duty
:Period(sec)
:Thedutyispulsewidt
h
peakoutputpowerof
oneperiod(%)
aHWS84
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 300P, 600P
+:6336HULHV,QVWUXFWLRQ0DQXDO
1.TerminalExplanation
Besuretoreadthisinstructionmanualthoroughlybeforeusing
thisproduct.Pay attentiontoall cautionsandwarningsbefore
usingthisproduct. Incorrectusagecould leadtoanelectrical
shock,damagetotheunitorafirehazard.
DANGER
●Neverusethisproduct inlocationswhere flammablegasor
ignitablesubstancesarepresent
WARNING
●Donottouchthisproductoritsinternalcomponentswhileit
isinoperation,orshortlyaftershutdown.Theremaybehigh
voltageorhightemperaturepresentandyoumayreceivean
electricshockorburn.
●Whenthe productisoperating, keep yourhandsand face
awayfromit;anaccidentmayinjureyou.
●Donotmakeunauthorisedchangestothisproduct,otherwise
youmayreceiveanelectricshockandvoidyourwarranty.
●Donotusethisproductintheeventoftheemissionofsmoke
orabnormalsmellandsoundetc.Itmightleadtofireand/or
electricshock.Insuchcases,pleasecontactus.Donotat-
temptrepairbyyourself,asitisdangerousfortheuser.
●Donotoperatetheseproductsinthepresenceofcondensa-
tion.Itmightleadtofireand/orelectricshock.
●Donotdroporinsertanythingintotheproduct.Itmightlead
toafailure,fireand/orelectricshock.Donotusetheprod-
uctwhichdropped.
CAUTION
●Thispowersupplyisdesignedforusewithinanendproduct.
●Confirmconnectionstoinput/output terminalsandsignal
terminalsarecorrect asindicatedin theinstructionmanual
beforeswitchingon.
●Inputvoltage,Outputcurrent,Outputpower,ambienttemper-
atureandambienthumidityshouldbekeptwithin specifica-
tions,otherwisetheproductwillbedamaged.
●Donotoperateand storethisproduct inanenvironment
wherecondensationmight occur.Insuch case, waterproof
treatmentisnecessary.
●Donotusethisproductinenvironmentwithastrongelectro-
magneticfield,corrosivegasorconductivesubstances.
●For applicationswhichrequire veryhighreliability (Nuclear
relatedequipment,trafficcontrolequipment,etc.)itisneces-
sarytoprovideafailsafemechanismintheendequipment.
●Theinformationinthis documentissubject tochangewith-
outpriornotice.Pleaserefertothelatestversionofthedata
sheet,etc.,forthemostup-todatespecificationsoftheprod-
uct.
●Nopartofthisdocumentmaybecopiedorreproducedinany
formwithoutpriorwrittenconsentofTDK-Lambda.
●Donotinjectabnormal voltagesintothe outputorsignal of
thisproduct.Theinjectionofreversevoltageorovervoltage
exceedingnominaloutput voltageintothe outputorsignal
terminalsmightcausedamagetointernalcomponents.
●Theoutputofthisproduct isconsideredto beahazardous
energylevel(The voltageis2V ormoreandthe poweris
240VAormore). Itmustnot bemadeaccessibleto users.
Protectionmustbe providedforService Engineersagainst
indirectcontactwith theoutputterminals and/ortoprevent
toolsbeingdroppedacrossthem.Whileworkingonthisprod-
uct,theACinput powermustbeswitched offandtheinput
andoutputvoltageshouldbezero.
●Thisproducthasabuilt-in fanforair-cooling. Donotblock
theairintakeandexhaustasthismightleadtofire.
CEMARKING
●CEMarkingwhenappliedtoaproductcoveredbythishand-
bookindicatescompliance withthelowvoltage directive
(2006/95/EC)inthatitcomplieswithEN60950-1.
BEFOREUSINGTHEPOWERSUPPLYUNIT
①V.ADJ:Outputvoltageadjustmenttrimmer.
(Theoutputvoltageriseswhenatrimmeristurnedclockwise.)
②ON:Output(PowerOn)indicationLED.
(Theindicatorturnsonwhenthepowersupplyoutputisinnormaloperating
condition.)
CN1 :ON/OFFcontrolsignal,Currentbalancesignal (only asfor
HWS600P),Powerfailsignal.(Referto2-2.)
④ :ProtectiveEarthterminal(Frameground),M4screw.
⑤ACinputterminalL:LiveLine(Fuseinline),M4screw.
⑥ACinputterminalN:Neutralline,M4screw.
⑦+:+Outputterminal(HWS300P:M4screwx2/HWS600P:M5screwx2)
⑧-:-Outputterminal(HWS300P:M4screwx2/HWS600P:M5screwx2)
Pleasepayextraattentiontothewiring.Incorrectconnectionwilldamagethepowersupply.
󱫀FrontPanelExplanation
HWS300P HWS600P
+
-
-
+
V.ADJ
ON
CN1
L
N
++ --
V.ADJ
CN1
ON
⑦⑧
④⑤⑥
LN
aHWS85
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 300P, 600P
󱫂CN1ConnectorpinConfigurationandFunction
PinNo.. Configuration
Function
1 COM GNDforPCsignals(OnlyasforHWS600P.HWS300PisNC.)
2PC
Currentbalanceterminal.
(Foroutputcurrentbalancinginparalleloperation.
OnlyasforHWS600P.HWS300PisNC.)
3 NC Noconnect
4 NC Noconnect
5 CNT RemoteON/OFFcontrolterminal.(PowersupplyON/OFFcontrolwithanexternalsignal.)
6 TOG GNDforCNTandPFsignals.(SameasPinNo.8)
7PF
Powerfailsignal(PFsignal)outputterminal.
(Usestheopencollectormethod.Astheoutputvoltagedrops,
orFANstops,PowerFailterminalwilloutputHigh.)
8 TOG GNDforCNTandPFsignals.(SameasPinNo.6)
CN1Connector&Housing&TerminalPin
PARTDESCRIPTION PARTNAME MANUFACT
PINHEADER S8B-PHDSS J.S.T.
SOCKETHOUSING PHDR-08VS J.S.T.
TERMINALPINS SPHD-002T-P0.5(AWG28-24)
SPHD-001T-P0.5(AWG26-22) J.S.T.
HANDCRIMPINGTOOL YRS-620(SPHD-002T-P0.5)
YC-610R(SPHD-001T-P0.5) J.S.T.
2
4
6
8
1
3
5
7
.TerminalConnectionMethod
Pleasepayextraattentiontothewiring.Incorrectconnection
willdamagethepowersupply.
Whenconnectinginputandoutputwiring,andCN1,input
AC-Lineshouldbeoff.
●Inputwiringandoutputwiringshallbeseparatedtoimprove
noisesensibility.
The protectiveearth(PE) must be connectedtothe
terminalorchassis.
RemoteON/OFFcontrollines shallbetwistedorused
shieldedwires.Separatefromloadline.
●Outputcurrentofeachterminalscrewshallbelessthan40A
forHWS300P.Andshallbelessthan60AforHWS600P.
HWS300PPanelSide(CommonHWS600P)
・Basicconnection
ConnectCNTterminaltoTOGterminalwiththeattached
connector.
・ON/OFFcontrolrequired
TOGterminalisgroundforCNTterminal.
・PFsignaloutputrequired
Opencollectormethodshownbelowshallbeused.
TOGterminalisgroundforPFterminal.
+
-
-
+
V.ADJ
L
N
ON
CN1
-LOAD+
CN1
+
-
-
+
V.ADJ
L
N
ON
CN1
-LOAD+
CN1
+
-
-
+
V.ADJ
L
N
ON
CN1
-LOAD+
CN1
PFsignal
GND
forsignal
aHWS86
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 300P, 600P
4.FunctionsandPrecautions
󱫀InputVoltageRange
Inputvoltagerangeis singlephase 85-265VAC(47-
63Hz)or120- 330VDC.Input voltage,whichisoutof
specification,maycauseunit damage.Rated inputvoltage
forsafetystandardapplicationis100-240VAC(50/60Hz).
󱫂OutputVoltageRange
Outputvoltageisset tothe ratedvoltagevalueat
shipment.V.ADJtrimmeronthefrontpanelsideisusedto
adjusttheoutputvoltagewithintherangespecified.
Outputvoltagerangeis within −20%- +10% ofrated
outputvoltage.
Toturn thetrimmer clockwise,the outputvoltagewillbe
increased.Takenotewhentheoutputvoltageisincreased
excessively,overvoltageprotection (OVP)function may
triggerandoutputvoltagewillbeshutdown.
Whenoutputvoltageincreased,averageoutputpowerand
peakoutputpowerhavetouselessthanspecification.
󱫄OverVoltageProtection(OVP)
TheOVPfunction(Inverter shutdownmethod, manual
resettype)isprovided.OVPfunctionoperateswithin115-
135%oftheratedoutputvoltagevalue,andtheoutputwill
beshutdownwhen OVPfunction trigger.ToresetOVP,
removethe inputof powersupply forafewminutes,and
thenre-input.Or,useCNTreset(remoteON/OFF:OFFto
ON).OVPvalueisfixedandnottobeadjustedexternally.
Neverapplymorethan ratedoutput voltagetooutput
terminal,whichmaylead damageto powersupply.Inthe
caseofinductiveload,usedecouplingdiodeatoutputline.
󱫆DelayShutDown
Thisproducthavea delayshut downfunction provided
toprotectpowersupplyandequipmentatthetimeofthe
consecutivepeakcurrent.Whentheproductoperatepeak
currentformorethan5seconds,delayshutdownfunction
operatesandtheoutputwillbeshutdown.
Toresetdelayshut down,remove theinputofpower
supplyforafew minutes,and thenre-input.Or,useCNT
reset(remoteON/OFF:OFFtoON).
DelayShutDownTime valueis fixedandnottobe
adjustedexternally.
Useitaboutthe peakelectricity inspecificationsrange.
Thedetailsseeat4-14.OutputPeakPower.
󱫈OverCurrentProtection(OCP)
TheOCPfunction(manualresettype)isprovided.Output
willbeshutdowninconditionovercurrentoroutputshort-
circuit.
ToresetOCP,removetheinputofpowersupplyforafew
minutes,andthenre-input. Or,use CNTreset(remote
ON/OFF:OFFtoON).
Alsoavoidovercurrent conditionor outputshort-circuit.
Otherwisetheproductwillbedamage.
OCPvalueisfixedandnottobeadjustedexternally.
󱫊
OverTemperatureProtection(OTP)
TheOTPfunction(manual resettype) isprovided.When
ambientorinternaltemperature risesabnormally, OTP
functionoperatesandoutputwillbeshutdown.Aftershut
down,removetheinput andcool itdowntoresetOTP.
Thenre-input.
Or,useCNTreset(remoteON/OFF:OFFtoON).
󱫌LowOutputDetectionCircuit(PF)
Lowoutputvoltagedetectioncircuitisprovided.PowerFail
(PF)signalwillturnHighleveltoindicatetheabnormal
statuswhentheoutputvoltagebecomeswithin65˜80%
ofratedvaluecausedbyeitherthedroporbrownoutofthe
inputvoltageorOCP, OVP,Delay ShutDownandOTP
etcfunctionoperation.Whenthebuilt-inFANmotorofthis
powersupplyunitstops, PFsignal willturntoH.The
PFsignalisisolated frominput andoutputbyaphoto-
coupler.Itusestheopencollectormethodshowninbelow.
󱫎RemoteON/OFFControl
RemoteON/OFFcontrolisprovided.
Usingthisfunction,output on/offis allowedtocontrol
withoutinputvoltageon/off. Theoutput isturnedtoON
whenTOGandCNTterminalsareshorted,andtheoutput
isturnedtoOFFwhentheseterminalsareopened.When
thefunctionisnotused,connectTOGandCNTterminals.
Thestandardsforthis functionare asfollows.TOG
terminalisreturnforCNTterminal.
(1) TTLcompatible. Themaximum inputvoltage toCNT
terminalis12V,and themaximum allowablereverse
voltageis‒1.0V.ThesinkcurrentforCNTterminalis3.5mA.
(2) AswitchandrelayoratransistorcanbeusedasON/
OFFswitch.
(3) Remote ON/OFF control circuit is isolated from
theinputandoutput bya photo-couplerandcanbe
controlledregardlessofthe outputpotential (+or-).
ConnectTOGterminaltogroundofcontrolsignal.
Themodeofcontrol
CNTLevelforTOGTerminal Output Built-inFan
ShortorL(0V-0.8V) ON Rotate
OpenorH(2.4V-12V) OFF Stop
PF
TOG
VCEmax=30V
ICmax=20mA
aHWS87
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 300P, 600P
󱫐OutputRipple&Noise
Thestandardspecificationfor maximumripple valueis
measuredspecifiedmeasurementcircuit(JEITA-RC9131A).
Whenloadlinesare longer,ripple becomeslarger.Inthis
case,electrolyticcapacitor,film capacitor,etc. mightbe
necessarytouseacross theload terminal.Theoutput
ripplecannotbemeasure accuratelyif theprobeground
leadofoscilloscopeistoolong.
󱫒SeriesOperation
Forseriesoperation,bothmethod(A)and(B)arepossible.
Theremightbeastep inthe outputrise waveformduring
seriesoperation.
(A)
(B)
.
󱫓ParallelOperation
Bothoperationsmode(A)and(B)arepossible.
(A) ToIncreasetheOutputCurrent(onlyasforHWS600P)
Currentbalancingfunctionis provided.Connecting
PCtoPCterminal andCOM toCOMterminal,the
currentbalancingfunctionactivates andoutput
currentofeachpowersupplyisequivalentlysupplied
toload.Wiresto PCterminals, COMterminalsshall
beasshortaspossibleandsamelengthandtwisted.
Paralleloperationispossibleupto2units.
1) Adjusttheoutputvoltageofeachpowersupplytobe
samevaluewithin100mV.
2) Usesamelengthandtypeofwiresforallloadlines.
3) Usethepowersupplywithintheratedoutputcurrent
forallparalleledmodels.
(B)ToUseasaBackupPowerSupply
1) Adjusttheoutputvoltageofeachpowersupplytobe
samevalue.
2) Setpowersupplyoutputvoltagehigherbytheforward
voltagedropofdiode.
3) Usewithinthespecificationsforoutputvoltage and
outputpower.
Method(A)ToIncreasetheOutputCurrent
(onlyasforHWS600P)
Method(B)ToUseasaBackupPowerSupply
CNT
TOG
SinkCurrent:3.5mA
Relay,Transistor,
TTL,etc
C
R
Power
Supply
+
-
Load
R:50Ω
C:4700pF
CoaxialCable
1.5m50Ω
Oscillo
scorp
100MHz
PowerSupply
Load
+
-
+
-
+
-
PowerSupply
Load
+
-
+
-
+
-
Load
+
-
PC COM
PC COM
+
-
+
-
+
-
PowerSupply
Load
+
-
+
-
+
OutputPower(W)=(Vo+Vf)xIo
Io
Vo
Vo+Vf
Vo+Vf
-
PowerSupply
Load
aHWS88
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
󱫔IsolationTest
Isolationresistancebetweenoutput and (chassis)shall
bemorethan100MΩat500VDCandbetweenoutputand
CNT・PFshallbemorethan10MΩat100VDC.Forsafety
operation,voltagesettingof DCisolation testermustbe
donebeforethetest.Ensurethatitisfullydischargedafter
thetest.
Output-FG(chassis):500VDC100MΩormore
Output-CNT·PF:100VDC10MΩormore
Note1."PC"and"COM"areNCinHWS300P.
󱫕WithstandVoltage
Thisseriesisdesigned towithstand 3.0kVACbetween
inputandoutput,2.5kVACbetweeninputand(chassis),
500VACbetweenoutputand (chassis),and100VAC
betweenoutputandCNT・PF terminaleach for1minute.
Whentestingwithstandvoltage, setcurrent limitof
withstandvoltagetestequipmentat20mA.
(Output-(chassis)andOutput-CNT・PF:100mA).
Theappliedvoltage mustbe graduallyincreasedfrom
zerototestingvalue andthen graduallydecreased for
shutdown.Whentimerisused,thepowersupplymaybe
damagedby highimpulse voltageat timerswitchonand
off.Connectinputandoutputasfollows.
Inthetestby stateof outputopen,thereisa thingthat
outputvoltageisgeneratedmomentarily.
Input-Output(dottedline):3.0kVAC1min.(20mA)
Input-(chassis)(solidline):2.5kVAC1min.(20mA)


      
Output-(chassis):500VAC1min.(100mA)
Output-CNT·PF:100VAC1min.(100mA)
Note1 "PC"and"COM"areNCinHWS300P.
Note2 Thisproducthave monolithicceramiccapacitor in
secondarycircuittoframeground.
AC(L)
+
-
AC(N)
PC
COM
CNT
TOG
PF
Isolation
Tester
AC(L)
+
-
AC(N)
PC
COM
CNT
TOG
PF
Isolation
Tester
AC(L)
+
-
AC(N)
PC
COM
CNT
TOG
PF
Withstand
Voltage
Tester
AC(L)
+
-
AC(N)
Withstand
Voltage
Tester
PC
COM
CNT
TOG
PF
AC(L)
+
-
AC(N)
PC
COM
CNT
TOG
PF
Withstand
Voltage
Tester
HWS 300P, 600P
aHWS89
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
Someofthe withstandvoltagetester maygenerate
highvoltageat thematchingwith monolithicceramic
capacitorandmaycausetheunitdamage.
So,pleasecheckthewaveformoftestvoltage.
󱫖OutputPeakpower
Thisproductmustbeusetosatisfy(a)and(b).
Allowablepeakoutputoperatingtimeislessthan5sec.
Whentheproductoperatepeakpowerformorethan5sec,
thedelayshutdownfunctionoperatesandtheoutputwill
shutdown.
Peakoutputpowerand averageoutput poweruse less
thanspecification.
Peakoutputpoweris limiteddepending onDuty.The
detailsseeat(b).
Theproductmightbedamagetousebeyondthelimitsof
(a)and(b).
Whenusingpulseload,anoisemaybeheardfrompower
supplyunit.Pleaseevaluateandcheckbeforeusing.
(a)Expressionofrelations
  AformulaaboutDuty
Aformulaaboutaverageoutputpower
Wp Peakoutputpower(W)
Wav Ratedaverageoutputpower(W)
(AverageoutputpowerofSpecification)
Wm Averageoutputpower(W)
τ Pulsewidthofpeakoutputpower(sec)
(Operatingtimeatpeakoutput)
T Period(sec)
(b)PeakoutputpowerVSPeakDuty
HWS300P
Vin:100VAC(dottedline)/Vin:200VAC(solidline)
HWS600P
Vin:100VAC(dottedline)/Vin:200VAC(solidline)
(%)100×=Duty T
τ
T
0(W)
a(W)
Wp
Wm
τ
Wav<Wm= +a
T
(Wp-a)×τ
40
35
30
25
20
15
10
5
0
300 400 500 600 700 800 900 1000
Duty(%)
Peakcutputpower(W)
T
0(W)
Wp Wm
τ
Wav<Wm= T
Wp×τ
40
35
30
25
20
15
10
5
0
600 1000 1400 1800 2200
Duty(%)
Peakcutputpower(W)
HWS 300P, 600P
aHWS90
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 300P, 600P
󱫀
OutputDeratingaccordingtotheMountingDirections.
Recommendedstandardmountingmethod is(A). Method
(B)isalsopossible.
Refertothederatingbelow.
HWS300P
HWS600P
󱫂OutputDerating
Ta(℃ ) Average Load (%)
Mounting(A) Mounting(B)
-10 +50 100
+70 50
Note1,Peakpowerdoesnothavethederating.
󱫄MountingMethod
(1) Forcedair-coolingtypepowersupply.
Thispowersupplyhas ventilatingholes onthefront
andbacksidepanels.Keepthesetwoareasfreelyas
muchaspossible.
(2) Themaximumallowablepenetrationis6mm.
Incompletethreadofmounting screwshould notbe
penetrated.
(3) Recommendedtorqueformountingscrew:M4screw
:1.27N·m(13.0kgf·cm)
5.MountingDirections
(D)Inhibit(A)StandardMounting (B)StandardMounting (C)Inhibit
(D)Inhibit(A)StandardMounting (B)StandardMounting (C)Inhibit
100
80
60
40
20
0
-10 0 20 40 50 70
AverageLoad(%)
AmbientTemperature(℃)
MountingA,B
Morethan50mm Morethan50mm
FrontSideBackSide
Airflow
Fan Top
(1) Theoutputloadlineandinputlineshallbeseparated
toimprovenoisesensitivity.
(2) Useall linesas thickandshortaspossible tomake
lowerimpedance.
(3) Attachingacapacitorto theload terminalscan
eliminatenoise.
(4) ForsafetyandEMIconsiderations,connectterminal
tothemountingsetgroundterminal.
(5) Recommendedtorquefortheterminal;
HWS600POutputterminal(M5screw)
:2.50N·m(25.5kgf·cm)
HWS300PInput, Outputterminal &HWS600P Input
terminal(M4screw)
:1.27N·m(13.0kgf·cm)
[ThePHDconnectormanufacturemethod]
ThisproductisusingSPHD-001T-P0.5orSPHD-002T-P0.5
connectormadefromJAPAN SOLDERLESSTERMINAL
MFGCOLTD.
Regardingtomanufactureof aconnector, itbecomes the
regulationasfollowing.
a).AppricableWireandCrimpingtool
Wiresizetouse forSPHD-001T-P0.5 isAWG#26
AWG#22andinsulationouterdiameterisφ1.0 〜φ1.5mm.
Wiresizetouse forSPHD-002T-P0.5 isAWG#28˜
AWG#24andinsulationouterdiameterisφ0.9 〜φ1.5mm.
Crimpingtoolisasblow.
Crimpingtool Crimpingapplicator Dies
AP-K2orAP-KS
MKS-LS-10orMKS-L-10
SPHD-001-05/SPHD-002-05
6.WiringMethod
aHWS91
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 300P, 600P
b).CrimpingOperation
Thereference valueof wirestrip is2.3mm.Aswirestrip
lengthdiffersdependingon typeof wireand crimping
method,decidethebest wirestrip lengthconsidering
processingcondition.Whenwire isstripped, donot
damageorcutoffwireconductores.
Tableofcrimpheight
SPHD-001T-P0.5
WireSize
InsulationO.D(mm)
Crimpheight(mm)
Conductorpart Conductorpart
AWG#26 1.3 0.60〜0.70 1.7
AWG#24 1.5 0.65〜0.75 1.8
AWG#22 1.4 0.70〜0.80 1.8
SPHD-002T-P0.5
WireSize
InsulationO.D(mm)
Crimpheight(mm)
Conductorpart Conductorpart
AWG#28 1.2 0.55〜0.60 1.6
AWG#26 1.3 0.60〜0.65 1.7
AWG#24 1.5 0.62〜0.67 1.8
Note1.Crimp heightatwirebarrel shouldbeset to pre-
determineddimensions.
Note2.Adjust crimpheightat wireinsulationbarrelto the
extentthatwireinsulationisslightly pressed, andset
itsothatcrimpingisnotexcessivery.
Note3. Crimpingconditionat wireinsulationbarrel isasbelow
Fig.1.
Note4.For AWG#28,#26,#24,useUL1007 type.For
AWG#22,useUL1061type.
Fig.1
Tableoftensilestrengthatcrimpedpart.
SPHD-001T-P0.5
Wiresize RequirementNmin. ActualvalueN
AWG#26 20 39.2 45.1
AWG#24 30 68.6 74.5
AWG#22 40 92.1 96.0
SPHD-002T-P0.5
Wiresize RequirementNmin. ActualvalueN
AWG#28 15 27.0 34.3
AWG#26 20 44.1 48.0
AWG#24 30 66.6 71.5
Fig.2:Examplesofdefectivecrimping
c).Insertingcontactintohousing
(1)Donotapply anypulling forcetocrimpedpart,and
insertcontactparalleltohousing.
(2)Insertcontactinto housingwithout stoppingto
innermost.
(3)Checksecurelockingpereachinsertionbypullingwire
softlyinordertocheckthatcontactdoesnotcomeoff
housing.Besides,checkwhetherthereisthebacklash
inthedirectionofinsertionaxis.
Defectexampleofslatinginsertion
d).MatingandUnmatingConnector
(1)Insertingconnector
Holdreceptaclehousingsecurely andinsert intoheader
straightagainsttoheaderpostuntilclicksounds.
(2)Unmatingconnector
Holdallwiressecurelyandfixreceptaclehousingbyfingers
soastopry,andthen,withdrawitonthematingaxis.
e).RoutingofWire
Routingwiresoasnottoapplyexternalforcetoconnector
exceptforcetosuch anextent thatwire slightlybuckles,
consideringanenoughlengthtorouteandfixingofwire.
Good
Wireconductorprotruding
lengthislong.
Wireconductorprotruding
lengthisshort.
Wirebarrelbiteswire
insulation.
Wireinsulationisnotcrimped
sufficiently.
Wireconductor
comesoff.
Fixreceptaclehousing Holdallwires
Header
7.ExternalFuseRating
Refertothefollowingfuseratingwhenselectingthe
externalfuses that aretobe usedoninputline. Surge
current flowswhenlineturns on.Use slow-blowortime-
lagtypefuse,notfast-blowfuse.Fuseratingisspecied
byin-rushcurrentvalueatlineturn-on.Donotselectthe
fuseaccordingtoinputcurrent(RMS.)valuesunderthe
actualloadcondition.
HWS300P:12A
HWS600P:20A
Coverofcontactingpart
Insertwithslanting
Housing
Contact
Coverofcontactingpart
aHWS92
Allspecificationsaresubjecttochangewithoutnotice.
Instruction Manual
HWS HWS HD HWS ME HWS-P
HWS 300P, 600P
8.Fanlifeexpectancy
TheFan-lifehaslimitation. Therefore,periodic
maintenancebyexchangingthelife-expiredfanisrequired
forthepowersupply.Thefollowingfigureshowsthelifeof
fan.Thebuilt-inFANmotorreplacementischargedPlease
contacttooursalesofficeforFANreplacement.
Thedifferencebetweenthe intaketemperature andthe
exhausttemperatureofthePowersupplyataverageload.
HWS300P:4℃
HWS600P:8℃
100500
1
10
Fanexhausttemperature(℃)
Lifeexpectancy(year
HWS600P
HWS300P
Measurementpointof
fanexhausttemperature
P.S.
AirFlow
50mm
Measuringpoint
Beforeconcludingthatthe unitis atfault,makethe
followingchecks.
(1) Checkiftheratedinputvoltageisconnected.
(2) Checkifthewiringofinputandoutputiscorrect.
(3) CheckiftheI/O terminalconnection isproperly
tightenbyregulatedtorque.
(4) Checkifthewirethicknessisenough.
(5) Checkiftheoutput voltagecontrol (V.adj)isproperly
adjusted.OVPmightbetriggedandoutputisshutdown.
(6) IfusefunctionoftheRemoteON/OFFcontrol,checkif
theRemoteON/OFFcontrolconnectorisnotopened.
Ifinopencondition,powersupplywillnotoutput.
(7) Checkifthebuilt-in FANis notstopped.IsFAN
stoppedbysomethingirregularsoretc?
IfFANstops,the PFsignal turnHigh leveland
OTPmightbeactivated.
(8) Powersupplyhasventilating holeson thefrontand
backpanels.Checkifthereisanyirregularsordust,etc.
(9) Isthe chassisof powersupplyhotabnormally?The
outputisshutdownbyOTPoperation.
Pleasere-inputaftertheunittocooldownsufficiently.
(10)Checkiftheoutputcurrentand outputwattage does
notoverspecification.
(11)Audiblenoisemaybeheardwhen inputvoltage
waveformisnotsinusoidal.
(12)Audiblenoisemaybeheardduring dynamicload
operation.
9.Beforeconcludingthattheunitisatfault…
Thisproductiswarrantedforaperiodof5yearsfromthe
dateofshipment.As forthe breakdownunderanormal
useduringfreewarranteeterm,repairisatfreeofcharge.
However,thebuilt-inFANmotorreplacementischarged.
Please contactto oursales officeforFANreplacement.
Pleasesee"8.fanlifeexpectancy"fortheexchangetime
offan.
Conditionsofusageatthefreeofchargewarranteeareas
follows.
(1) Averageoperating temperature(ambient temperature
ofthepowersupplyunit)isunder40ºC
(2) Averageloadfactoris80%orless.
(3) Mountingmethod:Standardmounting.
However,themaximumratingiswithintheoutputderating.
Followingcasesarenotcoveredbywarranty.
(1) Improperusagelikedroppingproducts,applyingshock
anddefectsfromoperationexceedingspecificationof
theunits.
(2) Defectsresultingfromnaturaldisaster(fire,flood).
(3) Unauthorizedmodificationsorrepair bythe buyers
defectsnotcausebyTDK-Lambda.
10.Rangeoffreewarranty
HWS_1503E
TDK-LambdaCorporation
NIHONBASHI OFFICE
6F Nittetsu Bldg.1-13-1 Nihonbashi, Chuo-ku, Tokyo 103-0027 Japan
Tel: +81-3-5201-7140 Fax: +81-3-5201-7139
Change of Content Specications or designs in this catalog are subject to change due to
improvements without prior notice.
Trademarks Company names, product names, service marks and/or logos used, quoted
and/or referenced in this catalog are trademarks or registered trademarks of TDK Corporation
or TDK-Lambda Corporation or any of its afliates in Japan and other countries. Not all
trademarks or registered trademarks stated herein are followed by (R) or (TM).
TDK logo TDK logo is a trademark or registered trademark of TDK Corporation.
http://www.tdk-lambda.com/
Catalog Usage Precautions
Please observe the following points when using this catalog for power supplies and related products of TDK-Lambda
Corporation (hereafter referred to simply as "our products"). Be sure to carefully read all precautions stated below before
beginning to use our products.
1.The contents of this catalog are subject to change without notice, for example related to product improvements and
other instances. Always check the latest information before deciding on a product.
2.Our products are designed and manufactured under the assumption that they will be used as integrated power
supplies for normal industrial applications. They are not designed and manufactured for use in high-safety
applications (applications requiring very high reliability and safety levels, where a reliability or safety problem could
directly involve the risk of serious injury or death). If the customer decides to use our products in a high-safety
application, appropriate fail-safe design features must be provided (such as incorporating protective circuitry and/or
protective equipment in the system, or incorporating redundancy in the system so that a single failure cannot lead to
instability). TDK-Lambda Corporation does not assume liability for any claims or damages either by the customer or
third parties arising from the use of our products for high-safety applications.
3.When designing equipment in which our products are to be used, as well as peripheral circuitry for such equipment,
always observe the "Product Usage Precautions" noted in this catalog and/or the product documentation and ensure
that maximum ratings, power supply voltage range, operation temperature range and other specifications are not
exceeded. TDK-Lambda Corporation does not assume liability for any claims or damages arising from the use of our
products in a way that exceeds specifications, or from a type of usage indicated as unsuitable for the respective
product in this catalog.
4.The operation outline and usage descriptions given in this catalog are examples. Before actual use of a product, all
external factors must be examined carefully in order to ensure appropriate circuit and implementation design.
TDK-Lambda Corporation does not assume liability for any claims or damages arising from indirect problems such as
EMI or mechanical effects from our products.
5.The technical information included in this catalog is intended only for the purpose of illustrating representative
operation or application of our products. It does not imply any guarantee or granting of license for intellectual
property rights or other rights held either by TDK-Lambda Corporation or third parties. TDK-Lambda Corporation does
not assume liability for any problems with third parties related to intellectual property rights arising from the use of our
products.
6.Products listed in this catalog may require export permission or authorization in compliance with the Foreign
Exchange and Foreign Trade Act.