DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RP08-AW
Series
www.recom-power.com REV.: 6/2018 PD-5
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Information Technology Equipment, General Requirements for Safety E196683 UL60950-1, 2nd Edition, 2014
C22.2 No. 60950-1-07, 2nd Edition, 2014
Information Technology Equipment, General Requirements for Safety
(LVD) TW1708010-001 IEC60950-1:2005, 2nd Edition +A2:2013
EN60950-1:2006 + A2:2013
RoHS2+ RoHS-2011/65/EU + AM-2015/863
Railways Condition Standard / Criterion
Railway Applications - Electrical Equipment used on rolling stock 15A100701E-C EN50155:2007
Environmental testing Part 2-1: Tests – Test A: Cold temperature: -25°C, Dwell Time: 2 hours EN60068-2-1:2007
Environmental testing Part 2-2: Tests – Test B: Dry heat temperature: +70°C, Dwell Time: 6 hours EN60068-2-2:2007
Environmental testing Part 2-30: Tests - Test Db: Damp heat,
cyclic (12 h + 12 h cycle)
temperature: +25 to +55°C
humidity: 90% to 100%RH
test Duration: 24 hours/cycle, 2 cycles
EN60068-2-30:2005
Railway applications - Fire protection on railway vehicles Part2:
Requirements for fire behaviour of materials and components EN45545-2:2013
Fire hazard testing Part 2-11: Glowing/hot-wire based testmethods –
Glow-wire flammability test method for end-products glow-wire test EN60695-2-11
Fire hazard testing Part 11-10: Test flames – 50 W horizontal and
vertical flame test methods vertical flame test EN60695-11-10
EMC Compliance Railway Condition Standard / Criterion
Railway applications - Electromagnetic compatibility EN50121-3-2:2006
Industrial, scientific and medical equipment – Radio frequency
disturbance characteristics – Limits and methods of measurement EN55011
ESD Electrostatic discharge immunity test Air ±2, 4,8kV, Contact ±2, 4, 6kV EN61000-4-2, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test
20V/m (80-1000MHz)
10V/m (1400-2100MHz)
5V/m (2100-2500MHz)
EN61000-4-3, Criteria A
Fast Transient and Burst Immunity DC Power Port: ±2kV EN61000-4-4, Criteria A
Surge Immunity DC Power Port: Line-Line ±0.5, 1kV
DC Power Port: Line-Earth ±0.5, 1.2kV EN61000-4-5, Criteria A
Immunity to conducted disturbances, induced by radio-frequency fields DC Power Port 10V EN61000-4-6, Criteria A
EMC Compliance Multimedia and IT Condition Standard / Criterion
Electromagnetic compatibility of multimedia equipment –Emission
Requirements EN55032:2015+AC:2016-07, Class B
Information technology equipment - Immunity characteristics - Limits
and methods of measurement EN55024:2010 + A1:2015
ESD Electrostatic discharge immunity test Air ±2, 4, 8kV, Contact ±2, 4, 6kV IEC61000-4-2:2008, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test 20V/m (80-1000MHz) IEC61000-4-3:2006+A1:2007 + A2:2010,
Criteria A
Fast Transient and Burst Immunity DC Power Port: ±2kV IEC61000-4-4:2012, Criteria A
Surge Immunity DC Power Port: ±2kV IEC61000-4-5:2014, Criteria A
Immunity to conducted disturbances, induced by radio-frequency fields DC Power Port 10V IEC61000-4-6:2013, Criteria A
Power Magnetic Field Immunity 50Hz 100A 1 minute
50Hz 1000A 1 second IEC61000-4-8:2009, Criteria A
Notes:
Note9: The standard modules meet EMI Class A or Class B with external components, see filter suggestions below on next page
Note10: An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5
Recom suggests Nippon chemi-con KY series 24Vin, 48Vin=220μF/100V or 110Vin=150μF/200V