SPECIFICATION
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE Note.5
FREQUENCY RANGE
POWERFACTOR (Typ.)
EFFICIENCY(Typ.)
ACCURRENT (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
SAFETY STANDARDS
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
1500ms,50msatfullload
24msatfullload
88~264VAC124~370VDC
47~63Hz
84% 84% 83% 85.5% 86.5% 87%
7A/115VAC3.5A/230VAC
18A/115VAC36A/230VAC
<3.5mA/240VAC
105~135% ratedoutputpower
Protectiontype:Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
UL60950-1, TUVEN60950-1,CCCGB4943(for24Vonly)approved
-10~+50 (Refertooutputloadderatingcurve)
20~90%RH non-condensing
-20~+85 ,10~95%RH
0.03%/ (0~50 )
10~500Hz,2G10min./1cycle,periodfor 60min.eachalongX, Y,Zaxes
133.4Khrsmin.MIL-HDBK-217F(25 )
170*120*93mm(L*W*H)
FileName:SP-500-SPEC2010-12-07
12V 13.5V 15V 24V 27V 48V
40A 36A 32A 20A 18A 10A
0~40A 0~36A 0~32A 0~20A 0~18A 0~10A
480W 486W 480W 480W 486W 480W
240mVp-p 240mVp-p 240mVp-p 240mVp-p 200mVp-p 300mVp-p
10~13.2V 12~15V 13.5~18V 20~26.4V 24~30V 41~56V
1.0% 1.0% 1.0% 1.0% 1.0% 1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
SP-500-12 SP-500-13.5 SP-500-15 SP-500-24 SP-500-27 SP-500-48
1.9Kg;8pcs/15.5Kg/1.06CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
RTH1orRTH2 50 FANON, 45 FANOFF, 70 outputshutdown
FANCONTROL,O.T.P.
OVERVOLTAGE
13.8~16.2V 15.5~18.2V 18~21V 27.6~32.4V 31~36.5V 57.6~67.2V
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload/ Over voltage / Over temperature
Forced air cooling by built-in DC fan
Built-in cooling Fan ON-OFF control
Built-in remote ON-OFF control
Built-in remote sense function
Fixed switching frequency at 110KHz
3 years warranty
Features :
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC/25 /70%RH
ENVIRONMENT
PROTECTION
EMICONDUCTION&RADIATION
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
HARMONICCURRENT
EMSIMMUNITY
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
Complianceto lightindustrylevel,criteria AEN61000-4-2,3,4,5,6,8,11;ENV50204,
PF>0.95/230VACPF>0.95/115VACatfullload
SAFETY &
EMC
(Note4)
500WSingleOutputwithPFCFunction SP-500 series
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
REMOTECONTROL
FUNCTION
RC+/RC-:Short=poweron;Open=poweroff
( for 24V only)
http://store.iiic.cc/