Type 12 Free-Standing Modular Enclosure Disconnects
Detail Sheet
see universal
opening detail
panel
panel
The dimensional information provided in this drawing is derived from information supplied by the
manufacturer of the equipment to be installed. Fit and function of all equipment should be checked
before and after installation to assure proper and safe operation and compliance with the applicable
regulations, codes and standards.
Universal opening must be filled with an operator adapter kit for the specific brand and type of
disconnect being used, (see page 381).
BA
C9.31
(236)
9.93
(252)
3.37
(86)
4.00
(102)
2.75
(70)
3.00
(76) 1.62
(41)
1.12
(28)
.28 D
(7)
(TYP)
D
Flange Mounting Universal Opening Detail
this area
represents
disconnect
switch or
circuit
breaker
Important Note
When ordering modular enclosure systems, be sure to
include all the necessary components.
1. Disconnect master or slave enclosure
2. Gasket kits and/or end plates (see page 259)
3. Operator adapter plates MUST be ordered for the
specific brand and type of disconnect being used,
(see page 381)
Disconnect switch (or circuit breaker), operating handle and
operating mechanism are not furnished with enclosure, see
disconnect ordering information, pages 260 - 270.
Modular Encl.
260
Type 12 Modular Enclosures
Notes: Refer to detail sheet for drawing information and associated dimensions. Dimensions are in inches.
Millimeters shown are for reference only. Data subject to change without notice.
* Do not install disconnects in this height enclosure.
(1) Dimension “D” does not include space for auxiliary switches.
The dimensional information provided in this table is derived from information supplied by the manufacturer of the equipment to be installed. Fit
and function of all equipment should be checked before and after installation to assure proper and safe operation and compliance with the applicable
regulations, codes and standards.
Type 12 Free-Standing Modular Enclosure Disconnects
Allen-Bradley®
Allen-Bradley Fuse Clip Rating Fuse Enclosure Height
Mechanism Amp Class 72 84
for Switches Amp Volt A B A B C D(1)
in. mm in. mm in. mm in. mm in. mm in. mm
DS30 30A (non) (non) -- 7.87 200 6.00 152 13.73 349 11.50 292 4.00 102 6.75 171
DS30 30A (non) (non) - 11.87 301 10.00 254 17.37 441 15.50 394 4.00 102 6.75 171
DS30 30A 30A 250V H,K,R 11.87 301 10.00 254 17.37 441 15.50 394 5.25 133 6.75 171
DS30 30A 30A 600V H,K,R 11.87 301 10.00 254 17.37 441 15.50 394 8.00 203 6.75 171
DS30 30A 30A 600V J 11.87 301 10.00 254 17.37 441 15.50 394 5.25 133 6.75 171
DS30 30A 60A 250V H,K 11.87 301 10.00 254 17.37 441 15.50 394 6.00 152 6.75 171
DS30 30A 60A 600V H,K 11.87 301 10.00 254 17.37 441 15.50 394 8.50 216 6.75 171
DS30 30A 60A 600V J 11.87 301 10.00 254 17.37 441 15.50 394 5.50 140 6.75 171
DS60 60A (non) (non) - 11.87 301 9.87 251 17.37 441 15.37 394 4.00 102 6.75 171
DS60 60A 30A 600V H,K,R 11.87 301 9.87 251 17.37 441 15.37 394 8.00 203 6.75 171
DS60 60A 60A 250V H,K,R 11.87 301 9.87 251 17.37 441 15.37 394 6.00 152 6.75 171
DS60 60A 60A 600V H,K,R 11.87 301 9.87 251 17.37 441 15.37 394 8.50 216 6.75 171
DS60 60A 60A 600V J 11.87 301 9.87 251 17.37 441 15.37 394 5.50 140 6.75 171
DS60 60A 100A 250V H,K 11.87 301 9.87 251 17.37 441 15.37 394 8.50 216 6.75 171
DS60 60A 100A 600V H,K 11.87 301 9.87 251 17.37 441 15.37 394 10.50 267 6.75 171
DS60 60A 100A 600V J 11.87 301 9.87 251 17.37 441 15.37 394 7.25 184 6.75 171
DS100 100A (non) (non) - 11.87 301 8.37 251 17.37 441 13.87 352 4.75 121 8.00 203
DS100 100A 100A 250V H,K,R 11.87 301 8.37 251 17.37 441 13.87 352 10.50 267 8.00 203
DS100 100A 100A 600V H,K,R 11.87 301 8.37 251 17.37 441 13.87 352 12.50 318 8.00 203
DS100 100A 100A 600V J 11.87 301 8.37 251 17.37 441 13.87 352 9.25 235 8.00 203
DS100 100A 200A 250V H,K 11.87 301 8.37 251 17.37 441 13.87 352 11.25 286 8.00 203
DS100 100A 200A 600V H,K 11.87 301 8.37 251 17.37 441 13.87 352 13.75 349 8.00 203
DS100 100A 200A 600V J 11.87 301 8.37 251 17.37 441 13.87 352 10.00 254 8.00 203
DS200 200A (non) (non) - 10.43 265 6.00 102 15.93 405 11.50 292 10.00 254 11.00 279
DS200 200A 200A 250V H,K,R 10.43 265 6.00 102 15.93 405 11.50 292 15.00 381 11.00 279
DS200 200A 200A 600V H,K,R 10.43 265 6.00 102 15.93 405 11.50 292 17.25 438 11.00 279
DS200 200A 200A 600V J 10.43 265 6.00 102 15.93 405 11.50 292 13.50 343 11.00 279
DS200 200A 400A 250V H,K 10.43 265 6.00 102 15.93 405 11.50 292 15.75 400 11.00 279
DS200 200A 400A 600V H,K 10.43 265 6.00 102 15.93 405 11.50 292 18.75 476 11.00 279
DS200 200A 400A 600V J 10.43 265 6.00 102 15.93 405 11.50 292 14.25 362 11.00 279
DS400 400A (non) (non) - * * * * 15.93 405 9.62 244 10.75 273 11.00 279
DS400 400A 400A 250V H,K,R * * * * 15.93 405 9.62 244 16.25 413 11.00 279
DS400 400A 400A 600V H,K,R * * * * 15.93 405 9.62 244 19.25 489 11.00 279
DS400 400A 400A 600V J * * * * 15.93 405 9.62 244 14.75 375 11.00 279
Allen-Bradley Circuit Breaker Type Enclosure Height
Mechanism for Amp 72 84
Circuit Breakers Manufacturer Frame(s) A B A B C D(1)
in. mm in. mm in. mm in. mm in. mm in. mm
M40 150A General Electric TED, THED, TEC 11.87 301 11.25 286 17.37 441 16.75 425 5.75 146 4.75 121
M40 150A Westinghouse F (series C) 11.87 301 11.25 286 17.37 441 16.75 425 5.00 127 4.75 121
M50 250A Westinghouse J (series C) 11.87 301 10.87 276 17.37 441 16.37 416 9.75 248 5.00 127
M60 400A Westinghouse K (series C) 11.87 301 10.62 270 17.37 441 16.12 409 9.75 248 6.25 159
1949V Disconnect Mechanism
Modular Encl.
Type 12 Modular Enclosures
261
Notes: Refer to detail sheet for drawing information and associated dimensions. Dimensions are in inches. Millimeters shown are for reference only.
Data subject to change without notice.
Type 12 Free-Standing Modular Enclosure Disconnects
Allen-Bradley ®
(1) Dimension “D” does not include space for auxiliary switches. The dimensional information provided in this table is derived from informa-
tion supplied by the manufacturer of the equipment to be installed. Fit and
function of all equipment should be checked before and after installation to
assure proper and safe operation and compliance with the applicable regula-
tions, codes and standards.
1494V Disconnect Mechanism
Allen-Bradley Fuse Clip Rating Fuse Enclosure Height
Mechanism Amp Class 72 84
for Switches Amp Volt A B A B C D(1)
in. mm in. mm in. mm in. mm in. mm in. mm
N30 30A (NON) (NON) - 9.87 251 9.37 238 15.37 390 14.87 378 4.75 121 6.50 165
NF30 30A 30A 250V H,K,R 9.87 251 9.37 238 15.37 390 14.87 378 6.50 165 6.50 165
NF30 30A 30A 600V H,K,R 9.87 251 9.37 238 15.37 390 14.87 378 9.25 235 6.50 165
NF30 30A 30A 600V J 9.87 251 9.37 238 15.37 390 14.87 378 6.50 165 6.50 165
NF30 30A 60A 250V H,K,R 9.87 251 9.37 238 15.37 390 14.87 378 7.25 184 6.50 165
NF30 30A 60A 600V H,K,R 9.87 251 9.37 238 15.37 390 14.87 378 9.75 248 6.50 165
NF30 30A 60A 600V J 9.87 251 9.37 238 15.37 390 14.87 378 6.75 171 6.50 165
N60 60A (NON) (NON) - 9.87 251 8.62 238 15.37 390 14.12 378 4.75 121 6.50 165
NF60 60A 30A 600V H,K,R 9.87 251 8.62 238 15.37 390 14.12 378 10.50 267 6.50 165
NF60 60A 60A 250V H,K,R 9.87 251 8.62 238 15.37 390 14.12 378 8.50 216 6.50 165
NF60 60A 60A 600V H,K,R 9.87 251 8.62 219 15.37 390 14.12 378 11.00 279 6.50 165
NF60 60A 60A 600V J 9.87 251 8.62 219 15.37 390 14.12 378 7.75 197 6.50 165
NF60 60A 100A 250V H,K,R 9.87 251 8.62 219 15.37 390 14.12 378 11.00 279 6.50 165
NF60 60A 100A 600V H,K,R 9.87 251 8.62 219 15.37 390 14.12 378 13.00 330 6.50 165
NF60 60A 100A 600V J 9.87 251 8.62 219 15.37 390 14.12 378 9.75 248 6.50 165
N100 100A (NON) (NON) - 9.87 251 6.75 171 15.37 390 12.25 311 4.75 121 7.25 184
NF100 100A 100A 250V H,K,R 9.87 251 6.75 171 15.37 390 12.25 311 11.50 292 7.50 191
NF100 100A 100A 600V H,K,R 9.87 251 6.75 171 15.37 390 12.25 311 13.50 343 7.50 191
NF100 100A 100A 600V J 9.87 251 6.75 171 15.37 390 12.25 311 10.25 260 7.50 191
NF100 100A 200A 250V H,K,R 9.87 251 6.75 171 15.37 390 12.25 311 12.25 311 7.75 197
NF100 100A 200A 600V H,K,R 9.87 251 6.75 171 15.37 390 12.25 311 14.75 375 7.75 197
NF100 100A 200A 600V J 9.87 251 6.75 171 15.37 390 12.25 311 11.00 279 7.75 197
N200 200A (NON) (NON) - 8.56 217 5.12 130 14.06 357 10.62 270 7.25 184 10.50 267
NF200 200A 200A 250V H,K,R 8.56 217 5.12 130 14.06 357 10.62 270 15.00 381 10.50 267
NF200 200A 200A 600V H,K,R 8.56 217 5.12 130 14.06 357 10.62 270 17.50 445 10.50 267
NF200 200A 200A 600V J 8.56 217 5.12 130 14.06 357 10.62 270 13.75 349 10.50 267
NF200 200A 400A 250V H,K,R 8.56 217 5.12 130 14.06 357 10.62 270 16.50 419 11.00 279
NF200 200A 400A 600V H,K,R 8.56 217 5.12 130 14.06 357 10.62 270 19.50 495 11.00 279
NF200 200A 400A 600V J 8.56 217 5.12 130 14.06 357 10.62 270 15.00 381 11.00 279
1494D Disconnect Mechanism
Allen-Bradley Circuit Breaker Type Enclosure Height
Mechanism for Amp 72 84
Circuit Breakers Manufacturer Frame(s) A B A B C D(1)
in. mm in. mm in. mm in. mm in. mm in. mm
N4/N40 150A General Electric TED, THED, TEC 9.87 251 9.25 235 15.37 390 14.75 375 5.87 149 4.62 117
N5/N55 225A General Electric TFK, THFK, TFC 9.87 251 8.50 216 15.37 390 14.00 356 8.87 225 4.75 121
N4/N40 150A Westinghouse F (series C) 9.87 251 9.25 235 15.37 390 14.75 375 5.87 149 4.62 117
N5/N50 250A Westinghouse J (series C) 9.87 251 8.50 216 15.37 390 14.00 356 8.87 225 4.75 121
Modular Encl.
262
Type 12 Modular Enclosures
Notes: Refer to detail sheet for drawing information and associated dimensions. Dimensions are in inches.
Millimeters shown are for reference only. Data subject to change without notice.
Type 12 Free-Standing Modular Enclosure Disconnects
Culter-Hammer®
* Do not install disconnects in this height enclosure.
(1) Wire bending space “B” does not allow the use of cable larger than 300 MCM in 72H enclosures.
(2) Wire bending space “B” does not allow the use of cable larger than 250 MCM in 72H enclosures.
(3) Wire bending space “B” does not allow the use of cable larger than 300 MCM in 84H enclosures.
(4) Wire bending space “B” does not allow the use of Westinghouse terminals TA1201NB1 in 84H enclosures.
C361 Disconnect Mechanism
The dimensional information provided in this table is derived from information supplied by the manufacturer of the equipment to be installed. Fit
and function of all equipment should be checked before and after installation to assure proper and safe operation and compliance with the applicable
regulations, codes and standards.
Cutler-Hammer Fuse Clip Rating Fuse Enclosure Height
Mechanism Amp Class 72 84
for Switches Amp Volt A B A B C D
in. mm in. mm in. mm in. mm in. mm in. mm
NC 30A (non) (non) - 11.87 301 10.50 267 17.37 441 16.00 406 4.75 121 6.25 159
SC21 30A 30A 250V H,K,R 11.87 301 10.50 267 17.37 441 16.00 406 7.75 197 6.25 159
SC61 30A 30A 600V H,K,R 11.87 301 10.50 267 17.37 441 16.00 406 7.75 197 6.25 159
SC61 30A 60A 250V H,K,R 11.87 301 10.50 267 17.37 441 16.00 406 8.25 210 6.25 159
ND 60A (non) (non) - 11.87 301 10.50 267 17.37 441 16.00 406 4.75 121 6.25 159
SD22 60A 30A 600V J 11.87 301 10.50 267 17.37 441 16.00 406 7.75 197 6.25 159
SD22 60A 60A 250V H,K,R 11.87 301 10.50 267 17.37 441 16.00 406 8.25 210 6.25 159
SD62 60A 60A 600V H,K,R 11.87 301 10.50 267 17.37 441 16.00 406 8.25 210 6.25 159
SD62 60A 60A 600V J 11.87 301 10.50 267 17.37 441 16.00 406 8.00 203 6.25 159
NE 100A (non) (non) - 11.87 301 10.12 257 17.37 441 15.62 397 4.25 108 7.50 191
SE263 100A 100A 250V H,K,R 11.87 301 10.12 257 17.37 441 15.62 397 9.00 229 7.50 191
SE263 100A 100A 600V H,K,R 11.87 301 10.12 257 17.37 441 15.62 397 9.00 229 7.50 191
SE263 100A 100A 600V J 11.87 301 10.12 257 17.37 441 15.62 397 7.75 197 7.50 191
NF 200A (non) (non) - 11.87 301 8.12 206 17.37 441 13.62 346 13.25 337 10.25 260
SF264 200A 200A 250V H,K,R 11.87 301 8.12 206 17.37 441 13.62 346 13.25 337 10.25 260
SF264 200A 200A 600V H,K,R 11.87 301 8.12 206 17.37 441 13.62 346 13.25 337 10.25 260
C371 Disconnect Mechanism
Cutler-Hammer Circuit Breaker Type Enclosure Height
Mechanism for Amp 72 84
Circuit Breakers Manufacturer Frame(s) A B A B C D
in. mm in. mm in. mm in. mm in. mm in. mm
C371E 150A Cutler-Hammer HMCP,FS,FH 11.87 301 11.62 295 17.37 441 17.12 435 6.00 152 5.75 146
C371F (1) 225A Cutler-Hammer HMCP,JS,JH,JL 11.87 301 11.50 292 17.37 441 17.00 432 11.00 279 8.25 210
C371F (1) 400A Cutler-Hammer HMCP,KS,KH 11.87 301 11.00 279 17.37 441 16.50 419 9.75 248 8.25 210
C371G (2) 600A Cutler-Hammer LS,LH 11.87 301 9.37 238 17.37 441 14.87 378 8.50 216 12.00 305
C371K (3) 800A Cutler-Hammer MS,MH * * * * 17.37 441 11.37 289 10.25 260 12.00 305
C371K (3) 1200A Cutler-Hammer NS,NH * * * * 17.37 441 11.37 289 10.25 260 12.00 305
C371E 150A Westinghouse F(series C) 11.87 301 11.62 295 17.37 441 17.12 435 6.00 152 5.75 146
C371F (1) 250A Westinghouse J(series C) 11.87 301 11.50 292 17.37 441 17.00 432 9.00 229 8.25 210
C371F (1) 400A Westinghouse K(series C) 11.87 301 11.00 279 17.37 441 16.50 419 9.75 248 8.25 210
C371G (2) 600A Westinghouse LA,LC 11.87 301 9.37 238 17.37 441 14.87 378 8.50 216 12.00 305
C371K (3) 800A Westinghouse MC * * * * 17.37 441 11.37 289 10.25 260 12.00 305
C371K (3)(4) 1200A Westinghouse NC * * * * 17.37 441 11.37 289 10.25 260 12.00 305
Modular Encl.
Type 12 Modular Enclosures
263
Notes: Refer to detail sheet for drawing information and associated dimensions. Dimensions are in inches. Millimeters shown are for reference only.
Data subject to change without notice.
Type 12 Free-Standing Modular Enclosure Disconnects
General Electric®
TDA Disconnect Mechanism
* Do not install disconnects in this height enclosure.
The dimensional information provided in this table is derived from information supplied by the manufacturer of the equipment to be installed. Fit
and function of all equipment should be checked before and after installation to assure proper and safe operation and compliance with the applicable
regulations, codes and standards.
General Electric Fuse Clip Rating Fuse Enclosure Height
Mechanism Amp Class 72 84
for Switches Amp Volt A B A B C D
in. mm in. mm in. mm in. mm in. mm in. mm
TDOM1A 30A (non) (non) - 11.87 301 12.37 314 17.37 441 17.87 454 7.00 178 5.50 140
TDOM1A 30A 30A 250V H,R 11.87 301 12.37 314 17.37 441 17.87 454 7.00 178 5.50 140
TDOM1B 30A 30A 600V H,R 11.87 301 12.37 314 17.37 441 17.87 454 11.50 292 5.50 140
TDOM1B 30A 60A 250V H,R 11.87 301 12.37 314 17.37 441 17.87 454 11.50 292 5.50 140
TDOM1B 30A 60A 600V H,R 11.87 301 12.37 314 17.37 441 17.87 454 11.50 292 5.50 140
TDOM1A 60A (non) (non) - 11.87 301 12.37 314 17.37 441 17.87 454 7.00 178 5.50 140
TDOM1B 60A 60A 250V H,R 11.87 301 12.37 314 17.37 441 17.87 454 11.50 292 5.50 140
TDOM1B 60A 60A 600V H,R 11.87 301 12.37 314 17.37 441 17.87 454 11.50 292 5.50 140
TDOM1B 60A 100A 250V H,R 11.87 301 12.37 314 17.37 441 17.87 454 11.50 292 5.50 140
TDOM1B 60A 100A 600V H,R 11.87 301 12.37 314 17.37 441 17.87 454 11.50 292 5.50 140
TDOM1A 100A (non) (non) - 11.87 301 12.37 314 17.37 441 17.87 454 7.00 178 5.5 140
TDOM1B 100A 100A 250V H,R 11.87 301 12.37 314 17.37 441 17.87 454 11.50 292 5.50 140
TDOM1B 100A 100A 600V H,R 11.87 301 12.37 314 17.37 441 17.87 454 11.50 292 5.50 140
TDOM1B 100A 200A 250V H,R 11.87 301 12.37 314 17.37 441 17.87 454 11.50 292 5.50 140
TDOM1B 100A 200A 600V H,R 11.87 301 12.37 314 17.37 441 17.87 454 11.50 292 5.50 140
TDOM2 200A (non) (non) - 11.87 301 9.75 248 17.37 441 15.25 387 7.00 178 9.25 235
TDOM2 200A 200A 250V H,R 11.87 301 9.75 248 17.37 441 15.25 387 15.50 394 9.25 235
TDOM2 200A 200A 600V H,R 11.87 301 9.75 248 17.37 441 15.25 387 15.50 394 9.25 235
General Electric Enclosure Height
Mechanism for Amp Circuit Breaker Type 72 84
Circuit Breakers ABA B CD
in. mm in. mm in. mm in. mm in. mm in. mm
TDOM1A 150A TEB, TEC, TED, THED 11.87 301 11.25 286 17.37 441 16.75 425 7.00 178 5.50 140
TDOM1B 150A TB1, TEC, TECL 11.87 301 11.25 286 17.37 441 16.75 425 11.50 292 5.50 140
TDOM1C 150A TEL 11.87 301 11.25 286 17.37 441 16.75 425 7.00 178 5.50 140
TDOM1D 150A THCL1 11.87 301 9.87 251 17.37 441 15.37 390 7.00 178 5.50 140
TDOM3 225A TFJ, TFK, THFK, TFL 11.87 301 10.87 276 17.37 441 16.37 416 10.50 267 6.00 152
TDOM4 400A TJJ, TJK4, THJK4, TJL4V 11.87 301 10.00 254 17.37 441 15.50 394 8.25 210 9.50 241
TDOM4 600A TJK6, THJK6, TJ4V, TJL4V 11.87 301 10.00 254 17.37 441 15.50 394 8.25 210 9.50 241
TDOM5 400A TB4, TJH6S 11.87 301 10.00 254 17.37 441 15.50 394 14.25 362 9.50 241
TDOM6 225A TLB2, THLC2 * * * * 17.37 441 14.87 378 11.75 298 9.50 241
TDOM6 400A TLB4, THLC4 * * * * 17.37 441 13.50 343 11.75 298 9.50 241
TDOM7 600A TB6 * * * * 17.37 441 11.75 298 18.25 464 9.50 241
TDOM7 800A TB8 * * * * 17.37 441 11.75 298 18.25 464 9.50 241
Modular Encl.
264
Type 12 Modular Enclosures
Notes: Refer to detail sheet for drawing information and associated dimensions. Dimensions are in inches.
Millimeters shown are for reference only. Data subject to change without notice.
Type 12 Free-Standing Modular Enclosure Disconnects
I-T-E Siemens®
Disconnect Cable Circuit Breaker Type
Mechanism Length
FHOE036 36 ED2 ,ED4, ED6, HED4, HED6, ED6ETI
FHOE036 36 CED6, CED6ETI
FHOF036 36 FD6, FXD6, HFD6, FXD6ETI
FHOF036 36 CFD6, CFD6ETI
FHOJ036 36 JD2, JD6, JXD6, HJD6, JXD6ETI, LD6, LXD6, HLD6, LXD6ETI, SHJD6, SLD6, SHLD6
FHOJ036 36 CJD6, CJD6ETI, CLD6, CLD6ETI, SCJD6, SCLD6
FHON048 48 MD6, HMD6, CMD6, MXD6ETI, CMD6ETI, SMD6, SHMD6, SCMD6, ND6, HND6, CND6, SND6, SCND6
* Non-standard mechanism with 48 inch operating cable must be specified.
(1) Flexible operating cable allows disconnect to be mounted within minimum and maximum of “C” dimension when “D” is minimum.
(2) Flexible operating cable allows disconnect to be mounted within minimum and maximum of “D” dimension when “C” is nominal.
I-T-E Siemens Circuit
Enclosure Height
Enclosure Cable Mechanism Breaker Amp Device ACD
Circuit Breakers Frame Height 72 84 nom min max min max
in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm
36 FHOE036 ED 125A 6.37 162 11.87 301 17.37 441 5.37 136 -2.75 -70 13.50 343 3.00 76 9.75 248
36 FHOE036 CED 125A 9.62 244 11.87 301 17.37 441 8.50 216 .06 15 16.87 428 3.00 76 9.75 248
18 36 FHOF036 FD 250A 9.50 241 11.87 301 17.37 441 5.62 143 2.43 62 13.87 352 4.50 114 8.50 216
36 FHOF036 CFD 250A 14.12 359 11.87 301 17.37 441 10.25 260 7.25 184 18.62 473 4.50 114 8.50 216
36 FHOJ036 JD,LD 400A,600A 11.00 279 11.87 301 17.37 441 5.25 133 -2.87 -73 13.43 341 7.50 191 10.12 257
36 FHOJ036 CJD 400A,600A 17.87 454 11.87 301 17.37 441 12.12 308 4.12 105 20.37 517 7.50 114 10.12 257
48 * ED 125A 6.37 162 11.87 301 17.37 441 5.37 136 -15.37 -390 26.25 667 3.00 76 24.43 621
48 * CED 125A 9.62 244 11.87 301 17.37 441 8.50 216 -12.00 -305 26.50 673 4.50 114 24.43 621
48 * FD 250A 9.50 241 11.87 301 17.37 441 5.62 143 -12.15 -309 26.50 673 4.50 114 23.00 584
18 48 * CFD 250A 14.12 359 11.87 301 17.37 441 10.25 260 -10.25 -260 30.37 771 4.50 114 23.00 584
48 * JD,LD 400A,600A 11.00 279 11.87 301 17.37 441 5.25 133 -15.43 -392 26.12 663 7.50 191 24.50 622
48 * CJD 400A,600A 17.87 454 11.87 301 17.37 441 12.12 308 -8.50 -216 33.00 838 7.50 191 24.50 622
48 FHON048 MD,ND 800A,1200A 16.00 406 11.87 301 17.37 441 8.12 206 -5.12 -130 21.43 544 9.00 229 20.50 521
48 * ED 125A 6.37 162 11.87 301 17.37 441 5.37 136 -13.37 -340 23.25 591 3.00 76 20.62 524
48 * CED 125A 9.62 244 11.87 301 17.37 441 8.50 216 -10.00 -254 26.50 673 3.00 76 20.62 254
48 * FD 250A 9.50 241 11.87 301 17.37 441 5.62 143 -13.00 -330 23.50 597 4.50 114 19.37 492
24 48 * CFD 250A 14.12 359 11.87 301 17.37 441 10.25 260 -8.25 -210 28.37 721 4.50 114 19.37 492
48 * JD,LD 400A,600A 11.00 279 11.87 301 17.37 441 5.25 133 -13.43 -343 23.12 587 7.50 191 20.93 532
48 * CJD 400A,600A 17.87 454 11.87 301 17.37 441 12.12 308 -6.50 -165 30.00 762 7.50 191 20.93 532
48 FHON048 MD,ND 800A,1200A 16.00 406 11.87 301 17.37 441 8.12 206 -3.12 -79 19.93 506 9.00 229 20.50 521
MAX-FLEX Disconnects
MAX-FLEX Disconnect Mechanism
The dimensional information provided in this table is derived from information supplied by the manufacturer of the equipment to be installed.
Fit and function of all equipment should be checked before and after installation to assure proper and safe operation and compliance with the
applicable regulations, codes and standards.
Modular Encl.
Type 12 Modular Enclosures
265
Notes: Refer to detail sheet for drawing information and associated dimensions. Flexible cable allows for variable disconnect mounting and adequate
wire bending space must be maintained Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice.
Type 12 Free-Standing Modular Enclosure Disconnects
Square D®
* Do not install disconnects in this height enclosure.
The dimensional information provided in this table is derived from information supplied by the manufacturer of the equipment to be installed. Fit and
function of all equipment should be checked before and after installation to assure proper and safe operation and compliance with the applicable
regulation, codes and standards.
9422 Disconnect Mechanism
Square D Fuse Clip Rating Fuse Enclosure Height
Mechanism Amp Class 72 84
for Switches Amp Volt A B A B C D
in. mm in. mm in. mm in. mm in. mm in. mm
RC-1 30A (non) (non) - 11.87 301 11.75 298 17.37 441 17.18 436 3.25 83 7.25 1842
RC-2 30A 30A 250V H,K,R 11.87 301 11.75 298 17.37 441 17.18 436 5.00 127 7.25 1842
RC-3 30A 30A 600V H,K,R 11.87 301 11.75 298 17.37 441 17.18 436 8.00 203 7.25 1842
RC-3 30A 30A 600V J 11.87 301 11.75 298 17.37 441 17.18 436 5.00 127 7.25 1842
RC-3 30A 60A 250V H,K,R 11.87 301 11.75 298 17.37 441 17.18 436 6.00 152 7.25 1842
TC-1 30A (non) (non) - 11.87 301 9.87 251 17.37 441 15.37 390 5.75 146 6.25 159
TC-2 30A 30A 250V H,K,R 11.87 301 9.87 251 17.37 441 15.37 390 5.75 146 6.25 159
TC-3 30A 30A 600V H,K,R 11.87 301 9.87 251 17.37 441 15.37 390 7.75 197 6.25 159
TC-3 30A 30A 600V J 11.87 301 9.87 251 17.37 441 15.37 390 5.75 146 6.25 159
TC-3 30A 60A 250V H,K,R 11.87 301 9.87 251 17.37 441 15.37 390 6.00 152 6.25 159
TD-1 60A (non) (non) - 11.87 301 10.75 273 17.37 441 16.25 413 6.50 165 6.75 171
TD-2 60A 30A 600V H,K,R 11.87 301 10.75 273 17.37 441 16.25 413 8.50 216 6.75 171
TD-2 60A 60A 250V H,K,R 11.87 301 10.75 273 17.37 441 16.25 413 6.50 165 6.75 171
TD-3 60A 60A 600V H,K,R 11.87 301 10.75 273 17.37 441 16.25 413 9.00 229 6.75 171
TD-3 60A 60A 600V J 11.87 301 10.75 273 17.37 441 16.25 413 6.50 165 6.75 171
TE-1 100A (non) (non) - 11.87 301 10.50 267 17.37 441 16.00 406 4.75 257 8.50 216
TE-2 100A 100A 250V H,K,R 11.87 301 10.50 267 17.37 441 16.00 406 7.50 191 8.50 216
TE-2 100A 100A 600V H,K,R 11.87 301 10.50 267 17.37 441 16.00 406 9.50 241 8.50 216
TE-2 100A 100A 600V J 11.87 301 10.50 267 17.37 441 16.00 406 6.25 159 8.50 216
TE-3 100A 200A 600V J 11.87 301 10.50 267 17.37 441 16.00 406 13.75 349 8.50 216
TF-1 200A (non) (non) - 11.87 301 9.12 232 17.37 441 14.62 371 5.50 140 11.75 298
TF-2 200A 200A 250V H,K,R 11.87 301 9.12 232 17.37 441 14.62 371 11.50 62 11.75 298
TF-2 200A 200A 600V H,K,R 11.87 301 9.12 232 17.37 441 14.62 371 14.00 356 11.75 298
TF-2 200A 200A 600V J 11.87 301 9.12 232 17.37 441 14.62 371 10.25 260 11.75 298
TF-3 200A 400A 600V J 11.87 301 9.12 232 17.37 441 14.62 371 14.50 368 11.75 298
Square D Enclosure Height
Mechanism for Amp Circuit Breaker Type 72 84
Circuit Breakers ABA B CD
in. mm in. mm in. mm in. mm in. mm in. mm
RN-1 100A FAL, FHL, FCL 7.87 200 6.87 174 17.37 441 16.37 416 5.25 133 5.50 140
RP-1 250A KAL, KHL, KCL 7.87 200 6.62 168 17.37 441 17.12 435 7.25 184 5.75 146
RR-1 400A LAL, LHL, Q4L * * * * 17.37 441 12.75 324 7.75 197 9.00 229
RR-2 400A ILL * * * * 17.37 441 17.12 435 11.00 279 15.75 400
RT-1 800A MEL * * * * 17.37 441 12.62 321 9.25 235 12.00 305
RT-1 1000A MAL, MHL * * * * 17.37 441 12.62 321 9.25 235 12.00 305
Modular Encl.
266
Type 12 Modular Enclosures
Notes: Refer to detail sheet for drawing information and associated dimensions. Dimensions are in inches.
Millimeters shown are for reference only. Data subject to change without notice.
Type 12 Free-Standing Modular Enclosure Disconnects
Westinghouse®
* Do not install disconnects in this height enclosure.
(1) Dimensions “C” and “D” on these disconnects do not include space for fuse blocks which are mounted separately.
AMT Disconnect Mechanism
The dimensional information provided in this table is derived from information supplied by the manufacturer of the equipment to be installed. Fit
and function of all equipment should be checked before and after installation to assure proper and safe operation and compliance with the applicable
regulation, codes and standards.
Westinghouse Fuse Clip Rating Fuse Enclosure Height Pivot Width
Mechanism Amp Class 60 72 C D
for Switches Amp Volt ABAB variable fixed
in. mm in. mm in. mm in. mm in. mm in. mm in mm
DS16U 30A (non) (non) - 13.12 333 13.25 337 18.62 473 18.75 476 5.25 133 9.00 229 7.00 178
DS121R 30A 30A 250V H,R 13.12 333 13.25 337 18.62 473 18.75 476 10.25 260 9.00 229 7.00 178
DS161U 30A 30A 600V H,J,R 13.12 333 13.25 337 18.62 473 18.75 476 12.25 311 9.00 229 7.00 178
DS122 30A 60A 250V H,R 13.12 333 13.25 337 18.62 473 18.75 476 10.25 260 9.00 229 7.00 178
DS162 30A 60A 600V H,J,R 13.12 333 13.25 337 18.62 473 18.75 476 12.25 311 9.00 229 7.00 178
DS26U 60A (non) (non) - 13.12 333 13.25 337 18.62 473 18.75 476 5.25 133 9.00 229 7.00 178
DS222R 60A 60A 250V H,R 13.12 333 13.25 337 18.62 473 18.75 476 10.25 260 9.00 229 7.00 178
DS262R 60A 60A 600V H,J,R 13.12 333 13.25 337 18.62 473 18.75 476 12.25 311 9.00 229 7.00 178
DS263 60A 100A 250V H,R 13.12 333 13.25 337 18.62 473 18.75 476 10.25 260 9.00 229 7.00 178
DS263 60A 100A 600V H,J,R 13.12 333 13.25 337 18.62 473 18.75 476 12.25 311 9.00 229 7.00 178
DS36U 100A (non) (non) - 13.12 333 13.25 337 18.62 473 18.75 476 5.25 133 9.00 229 7.00 178
DS363R 100A 100A 250V H,R 13.12 333 13.25 337 18.62 473 18.75 476 10.25 260 9.00 229 7.00 178
DS363R 100A 100A 600V H,J,R 13.12 333 13.25 337 18.62 473 18.75 476 12.25 311 9.00 229 7.00 178
DS364 (1) 100A 200A 250V H,R 13.12 333 13.25 337 18.62 473 18.75 476 5.25 133 9.00 229 7.00 178
DS364 (1) 100A 200A 600V H,J,R 13.12 333 13.25 337 18.62 473 18.75 476 5.25 133 9.00 229 7.00 178
DS46U 200A (non) (non) - 13.12 333 11.00 279 18.62 473 16.50 419 6.00 152 12.00 305 10.00 254
DS464R 200A 200A 250V H,R 13.12 333 11.00 279 18.62 473 16.50 419 14.00 356 12.00 305 10.00 254
DS464R 200A 200A 600V H,R 13.12 333 11.00 279 18.62 473 16.50 419 15.25 387 12.00 35 10.00 254
DS464R 200A 200A 600V J 13.12 333 11.00 279 18.62 473 16.50 419 14.00 356 12.00 305 10.00 254
DS465 (1) 200A 400A 250V H,J,R 13.12 333 11.00 279 18.62 473 16.50 419 6.00 152 12.00 305 10.00 254
DS465 (1) 200A 400A 600V H,J,R 13.12 333 11.00 279 18.62 473 16.50 419 6.00 152 12.00 305 10.00 254
Westinghouse Enclosure Height Pivot Width
Mechanism for Amp Circuit Breaker Type 72 84 C D
Circuit Breakers ABAB variable fixed
in. mm in. mm in. mm in. mm in. mm in. mm in mm
EB 100A EB 13.12 333 12.37 314 18.62 473 17.87 454 5.50 140 9.25 235 7.25 184
FB Tri-Pac 100A FB Tri-Pac 13.12 333 12.37 314 18.62 473 17.87 454 8.25 210 9.25 235 7.25 184
MCP 150A MCP (0-4) current limiting 13.12 333 12.37 314 18.62 473 17.87 454 8.25 210 9.25 235 7.25 184
F Frame 150A F (series C) 13.12 333 12.37 314 18.62 473 17.87 454 5.50 140 9.25 235 7.25 184
J Frame 250A J (series C) 13.12 333 9.50 241 18.62 473 15.00 381 6.75 36 9.25 235 - -
K Frame 400A K (series C) 13.12 333 9.00 229 18.62 473 14.50 368 8.25 210 9.25 235 - -
LA Tri-Pac 400A LA Tri-Pac * * * * 18.62 473 16.50 419 14.25 362 12.00 305 - -
LA, LC 600A LA, LAB, HLA, LC, HLC 13.12 333 11.00 279 18.62 473 16.50 419 9.00 229 12.00 305 - -
MC 800A MC, HMC * * * * 18.62 473 12.87 327 10.50 267 12.00 305 - -
NB Tri-Pac 800A NB Tri-Pac * * * * 18.62 473 12.87 327 10.50 267 12.00 305 - -
NB, NC 1200A NB, HNB, NC, HNC * * * * 18.62 473 12.87 327 10.50 267 12.00 305 - -
Modular Encl.
Type 12 Modular Enclosures
267
Notes: Refer to detail sheet for drawing information and associated dimensions. Dimensions are in inches. Millimeters shown are for reference only.
Data subject to change without notice.
Type 12 Free-Standing Modular Enclosure Disconnects
Westinghouse
* Do not install disconnects in this height enclosure.
(1) Dimensions "C" and "D" on these disconnects do not include space for fuse blocks which are mounted separately.
The dimensional information provided in this table is derived from information supplied by the manufacturer of the equipment to be installed. Fit and
function of all equipment should be checked before and after installation to assure proper and safe operation and compliance with the applicable
regulation, codes and standards.
SM Disconnect Mechanism
Westinghouse Fuse Clip Rating Fuse Enclosure Height
Mechanism Amp Switch Type Class 72 84
for Switches ABABCD
in. mm in. mm in. mm in. mm in. mm in. mm
SM100R 30A De-ion Switch - 11.31 287 11.25 286 16.81 427 16.75 425 6.62 168 4.75 121
SM100R 60A De-ion Switch - 11.31 287 11.25 286 16.81 427 16.75 425 6.62 168 4.75 121
SM100R 100A De-ion Switch - 11.31 287 9.75 248 16.81 427 15.25 387 6.62 168 5.25 121
SM100SFR 30A DS121R H,R 11.31 287 11.50 292 16.81 427 17.00 432 7.00 178 5.50 140
SM100SFR 30A DS122 H,R 11.31 287 11.50 292 16.81 427 17.00 432 7.87 200 5.50 140
SM100SFR 60A DS222R H,R 11.31 287 11.50 292 16.81 427 17.00 432 7.87 200 5.50 140
SM100SFR 30A DS161R H,R 11.31 287 11.50 292 16.81 427 17.00 432 10.00 254 5.50 140
SM100SFR 30A DS161R J 11.31 287 11.50 292 16.81 427 17.00 432 7.25 184 5.50 140
SM100SFR 60A DS262H J 11.31 287 11.50 292 16.81 427 17.00 432 7.25 184 5.50 140
SM100SFR 30A DS162 H,R 11.31 287 11.50 292 16.81 427 17.00 432 10.37 263 5.50 140
SM100SFR 60A DS262R H,R 11.31 287 11.50 292 16.81 427 17.00 432 10.37 263 5.50 140
SM100SFR 100A DS363R(250V) H,R 11.31 287 11.50 292 16.81 427 17.00 432 10.25 260 5.50 140
SM100SFR 100A DS363R(600V) H,R 11.31 287 11.50 292 16.81 427 17.00 432 12.12 308 5.50 140
SM100SFR 60A DS263(600V) H,R 11.31 287 11.50 292 16.81 427 17.00 432 12.12 308 5.50 140
SM100SFR 100A DS363R J 11.31 287 11.50 292 16.81 427 17.00 432 8.87 225 5.50 140
SM150R 30A DS16U Switch - 11.31 287 11.50 292 16.81 427 17.00 432 5.12 130 5.50 140
SM150R 60A DS26U Switch - 11.31 287 11.50 292 16.81 427 17.00 432 5.12 130 5.50 140
SM150R (1) 100A DS36U Switch - 11.31 287 11.50 292 16.81 427 17.00 432 5.12 130 5.50 140
SM150R (1) 100A DS364 H,R 11.31 287 11.50 292 16.81 427 17.00 432 5.12 130 5.50 140
SM200SR (1) 200A DS46U Switch - 10.87 276 9.00 229 16.37 416 14.50 368 7.37 187 6.75 171
SM200SR (1) 200A DS465 Switch H,R 10.87 276 9.00 229 16.37 416 14.50 368 7.37 187 6.75 171
SM200SFR 200A DS464R H,R 10.87 276 9.00 229 16.37 416 14.50 368 15.25 387 6.75 171
Westinghouse Enclosure Height
Mechanism for Amp Circuit Breaker Type 72 84
Circuit Breakers ABA B CD
in. mm in. mm in. mm in. mm in. mm in. mm
SM150R 100A EB 11.31 287 10.50 267 16.81 427 16.00 406 5.12 130 5.50 140
SM101PR 100A FB Tri-Pac 11.31 287 10.50 267 16.81 427 16.00 406 8.00 203 5.50 140
SM101PR 150A MCP (0-4) current limiting 11.31 287 10.50 267 16.81 427 16.00 406 8.00 203 5.50 140
SM150R 150A F (series C) 11.31 287 10.50 267 16.81 427 16.00 406 8.00 203 5.50 140
SM250JR 250A J (series C) 10.87 276 8.00 203 16.37 416 13.50 343 8.50 216 7.50 191
SM400KR 400A K (series C) 10.87 276 7.62 194 16.37 416 13.12 333 9.12 232 7.50 191
SM400PR 400A LA Tri-Pac 10.87 276 7.75 197 16.37 416 13.25 337 14.50 368 9.75 248
SM400R 600A LA, LAB, HLA, LC, HLC 10.87 276 7.75 197 16.37 416 13.25 337 9.25 50 9.75 248
SM400R 600A LA, LAB, HLA, LC, HLC 10.87 276 7.75 197 16.37 416 13.25 337 9.25 50 9.75 248
SM800R 800A MC, HMCL * * * * 16.37 416 9.62 244 10.75 581 9.75 248
SM400PR 800A NB, Tri-Pac * * * * 16.37 416 9.62 244 16.87 428 9.75 248
SM1200R 1200A NB, HNB, NC, HNC * * * * 16.37 416 9.62 244 10.75 581 9.75 248
Modular Encl.
268
Type 12 Modular Enclosures
Notes: Refer to detail sheet for drawing information and associated dimensions. Dimensions are in inches.
Millimeters shown are for reference only. Data subject to change without notice.
General Electric
Standard enclosures designed to accept variable depth
type TDA.
General Electric TDA disconnect switch:
1. Disconnect switch, (QMR, QMW)
2. Operating mechanism
3. Operating handle TDA1
4 Fuse clip kit or no-fuse kit, (if required)
5. Line and load connectors, (if necessary)
6. Extended length drive rod, (if required)
NOTE: These items can be ordered as an assembly.
General Electric TDA circuit breaker:
1. Circuit breaker
2. Operating mechanism
3. Operating handle TDA1
4. Line and load connectors, (if necessary)
5. Extended length drive rod, (if required)
I-T-E Siemens
Standard enclosures designed to accept MAX-FLEX
type FHO.
I-T-E MAX-FLEX circuit breaker:
1. Circuit breaker
2. Operating mechanism
3. Operating handle
4. Line and load connectors, (if necessary)
5. Operating cable
NOTE: Items 2,3 and 5 can be ordered as an assembly,
standard with a 36 inch long operating cable. All 24 inch
deep enclosures require a 48 inch long cable.
Square D
Standard enclosures designed to accept variable depth
type 9422.
Square D 9422 disconnect switch:
1. Disconnect switch
2. Operating mechanism
3. Operating handle
4. Fuse clip kit, (if required)
5. Line and load connectors, (if necessary)
6. Connecting rod
Square D 9422 circuit breaker:
1. Circuit breaker
2. Operating mechanism
3. Operating handle
4. Line and load connectors, (if necessary)
5. Connecting rod
Type 12 Free-Standing Modular Enclosure Disconnects
Disconnect Ordering Information
Allen-Bradley
Standard enclosures designed to accept variable depth
type 1494V.
Allen-Bradley 1494V disconnect switch:
1. Disconnect switch
2. Operating mechanism
3. Operating handle
4. Fuse block kit, (if required)
5. Fuse clip kit, (if required)
6. Line and load connectors, (if necessary)
7. Connecting rod
Allen-Bradley 1494V circuit breaker:
1. Circuit breaker (General Electric, Westinghouse)
2. Operating mechanism
3. Operating handle
4. Line and load connectors, (if necessary)
5. Connecting rod
Standard enclosures designed to accept fixed depth type
1494F or 1494D.
Allen-Bradley 1494F disconnect switch:
1. Disconnect switch
2. Operating mechanism
3. Operating handle
4. Fuse block kit, (if required)
5. Fuse clip kit, (if required)
6. Line and load connectors, (if necessary)
Allen-Bradley 1494D circuit breaker:
1. Circuit breaker (General Electric, Westinghouse)
2. Operating mechanism
3. Operating handle
4. Line and load connectors, (if necessary)
5. Slide mechanism
Cutler-Hammer
Standard enclosures designed to accept variable depth
type C361 or C371.
Cutler-Hammer C361 disconnect switch:
1. Disconnect switch
2. Operating mechanism
3. Operating handle
4. Fuse clip kit (if required)
5. Line and load connectors (if necessary)
NOTE: Items 1,2 and 3 can be ordered as an assembly.
Cutler-Hammer C371 circuit breaker:
1. Circuit breaker (Cutler-Hammer, Westinghouse)
2. Operating mechanism
3. Operating handle
4. Line and load connectors (if necessary)
NOTE: Items 2 and 3 can be ordered as an assembly.
Modular Encl.
Type 12 Modular Enclosures
269
Type 12 Free-Standing Modular Enclosure Disconnects
Disconnect Ordering Information
Westinghouse
Standard enclosures designed to accept below handle
type AMT.
Westinghouse AMT disconnect switch:
1. Disconnect switch
2. Pivot mechanism assembly for below handle mounting
3. Backplate and yoke assembly for below handle
mounting
4. Operating handle
5. Fuse block kit, (if required)
6. Fuse clip kit (if required)
7. Line and load connectors, (if necessary)
8. Connecting rod
Westinghouse AMT circuit breaker:
1. Circuit breaker
2. Pivot mechanism assembly for below handle mounting
3. Backplate and yoke assembly for below handle
mounting
4. Operating handle
5. Line and load connectors, (if necessary)
6. Fuse clip kit, (if required)
7. Connecting rod
Standard enclosures designed to accept fixed depth
type SM.
Westinghouse SM disconnect switch:
1. Disconnect switch
2. Operating mechanism
3. Operating handle
4. Fuse block kit, (if required)
5. Fuse clip kit, (if required)
6. Line and load connectors, (if necessary)
Westinghouse SM circuit breaker:
1. Circuit breaker
2. Operating mechanism
3. Operating handle
4. Line and load connectors, (if necessary)
Important Note
When ordering modular flange-mounted disconnect
equipment, be sure to include all necessary
components listed below.
1. Enclosure includes the following equipment:
Enclosure door locking handle and rods
Door interlocking system
Interlocking connecting rod
Adjustable bracket, (see note 4)
2. Operator adapter plate, gasket and hardware for the type
of disconnect device being used MUST be ordered
separately (see page 381)
3. Modular gasket kits and/or end plates (see page 259)
4. 24 inch deep enclosures include an adjustable bracket for
mounting some disconnects:
Cutler-Hammer C361 device
Cutler-Hammer C371 E and F devices unless long
connecting rod C371CS1 is specified
Cutler-Hammer C371 G and K devices unless long
connecting rod C371CS2 is specified
General Electric TDA device unless extended length rod
TDSR is specified
Square D 9422 device unless extra long connecting rod
9422-R2 is specified
Note: Some devices require two rods, consult the device
manufacturer (Westinghouse AMT below handle device)
5. Disconnects and related components are available from
the manufacturer
6. The disconnect ordering information provided is derived
from information supplied by the manufacturer of the
equipment to be installed. Fit and function of all
equipment should be checked before and after installation
to assure proper and safe operation and compliance with
the applicable regulations, codes and standards.
Modular Encl.
270
Type 12 Modular Enclosures