TL/F/11708
DP83256/56-AP/57 PLAYERaDevice (FDDI Physical Layer Controller)
PRELIMINARY
October 1994
DP83256/56-AP/57
PLAYERaTM Device (FDDI Physical Layer Controller)
General Description
The DP83256/56-AP/57 Enhanced Physical Layer Control-
ler (PLAYERadevice) implements one complete Physical
Layer (PHY) entity as defined by the Fiber Distributed Data
Interface (FDDI) ANSI X3T9.5 standard.
The PLAYERadevice integrates state of the art digital
clock recovery and improved clock generation functions to
enhance performance, eliminate external components and
remove critical layout requirements.
FDDI Station Management (SMT) is aided by Link Error
Monitoring support, Noise Event Timer (TNE) support, Op-
tional Auto Scrubbing support, an integrated configuration
switch and built-in functionality designed to remove all strin-
gent response time requirements such as PCÐReact and
CFÐReact.
Features
YSingle chip FDDI Physical Layer (PHY) solution
YIntegrated Digital Clock Recovery Module provides en-
hanced tracking and greater lock acquisition range
YIntegrated Clock Generation Module provides all neces-
sary clock signals for an FDDI system from an external
12.5 MHz reference
YAlternate PMD Interface (DP83256-AP/57) supports
UTP twisted pair FDDI PMDs with no external clock re-
covery or clock generation functions required
YNo External Filter Components
YConnection Management (CMT) Support (LEM, TNE,
PCÐReact, CFÐReact, Auto Scrubbing)
YFull on-chip configuration switch
YLow Power CMOS-BIPOLAR design using a single 5V
supply
YFull duplex operation with through parity
YSeparate management interface (Control Bus)
YSelectable Parity on PHY-MAC Interface and Control
Bus Interface
YTwo levels of on-chip loopback
Y4B/5B encoder/decoder
YFraming logic
YElasticity Buffer, Repeat Filter, and Smoother
YLine state detector/generator
YSupports single attach stations, dual attach stations
and concentrators with no external logic
YDP83256 for SAS/DAS single path stations
YDP83257 for SAS/DAS single/dual path stations
YDP83256-AP for SAS/DAS single path stations that re-
quire the alternate PMD interface
TL/F/11708 1
FIGURE 1-1. FDDI Chip Set Overview
TRI-STATEÉis a registered trademark of National Semiconductor Corporation.
BMACTM, BSITM, CDDTM, CDLTM , CRDTM, CYCLONETM, MACSITM, PLAYERTM , PLAYERaTM and TWISTERTM are trademarks of National Semiconductor Corporation.
C1995 National Semiconductor Corporation RRD-B30M115/Printed in U. S. A.
Table of Contents
1.0 FDDI CHIP SET OVERVIEW
1.1 FDDI 2-Chip Set
1.2 FDDI TP-PMD Solutions
2.0 ARCHITECTURE DESCRIPTION
2.1 Block Overview
2.2 Interfaces
3.0 FUNCTIONAL DESCRIPTION
3.1 Clock Recovery Module
3.2 Receiver Block
3.3 Transmitter Block
3.4 Configuration Switch
3.5 Clock Generation Module
3.6 Station Management Support
3.7 PHY-MAC Interface
3.8 PMD Interface
4.0 MODES OF OPERATION
4.1 Run Mode
4.2 Stop Mode
4.3 Loopback Mode
4.4 Device Reset
4.5 Cascade Mode
5.0 REGISTERS
5.1 Mode Register (MR)
5.2 Configuration Register (CR)
5.3 Interrupt Condition Register (ICR)
5.4 Interrupt Condition Mask Register (ICMR)
5.5 Current Transmit State Register (CTSR)
5.6 Injection Threshold Register (IJTR)
5.7 Injection Symbol Register A (ISRA)
5.8 Injection Symbol Register B (ISRB)
5.9 Current Receive State Register (CRSR)
5.10 Receive Condition Register A (RCRA)
5.11 Receive Condition Register B (RCRB)
5.12 Receive Condition Mask Register A (RCMRA)
5.13 Receive Condition Mask Register B (RCMRB)
5.14 Noise Threshold Register (NTR)
5.15 Noise Prescale Threshold Register (NPTR)
5.16 Current Noise Count Register (CNCR)
5.17 Current Noise Prescale Count Register (CNPCR)
5.18 State Threshold Register (STR)
5.19 State Prescale Threshold Register (SPTR)
5.20 Current State Count Register (CSCR)
5.21 Current State Prescale Count Register (CSPCR)
5.22 Link Error Threshold Register (LETR)
5.23 Current Link Error Count Register (CLECR)
5.24 User Definable Register (UDR)
5.25 Device ID Register (DIR)
5.26 Current Injection Count Register (CIJCR)
5.27 Interrupt Condition Comparison Register (ICCR)
5.28 Current Transmit State Comparison Register
(CTSCR)
5.29 Receive Condition Comparison Register A (RCCRA)
5.30 Receive Condition Comparision Register B (RCCRB)
5.31 Mode Register 2 (MODE2)
5.32 CMT Condition Comparison Register (CMTCCR)
5.33 CMT Condition Register (CMTCR)
5.34 CMT Condition Mask Register (CMTCMR)
5.35 Reserved Registers 22H-23H (RR22H-RR23H)
5.36 Scrub Timer Threshold Register (STTR)
5.37 Scrub Timer Value Register (STVR)
5.38 Trigger Definition Register (TDR)
5.39 Trigger Transition Configuration Register (TTCR)
5.40 Reserved Registers 28H-3AH (RR28H-RR3AH)
5.41 Clock Generation Module Register (CGMREG)
5.42 Alternate PMD Register (APMDREG)
5.43 Gain Register (GAINREG)
5.44 Reserved Registers 3EH-3FH (RR3EH-RR3FH)
6.0 SIGNAL DESCRIPTIONS
6.1 DP83256VF Signal Descriptions
6.2 DP83256VF-AP Signal Descriptions
6.3 DP83257VF Signal Descriptions
7.0 ELECTRICAL CHARACTERISTICS
7.1 Absolute Maximum Ratings
7.2 Recommended Operating Conditions
7.3 DC Electrical Characteristics
7.4 AC Electrical Characteristics
8.0 CONNECTION DIAGRAMS
8.1 DP83256VF Connection Diagram/Pin Descriptions
8.2 DP83256VF-AP Connection Diagram/Pin Descrip-
tions
8.3 DP83257VF Connection Diagram/Pin Descriptions
9.0 PACKAGE INFORMATION
9.1 Land Patterns
9.2 Mechanical Drawings
2
1.0 FDDI Chip Set Overview
National Semiconductor’s next generation FDDI 2-chip set
consists of two components as shown in
Figure 1-1
. The
PLAYERadevice integrates the features of the DP83231
CRDTM Clock Recovery Device, DP83241 CDDTM Clock
Distribution Device, and DP83251/55 PLAYERTM Physical
Layer Controller. In addition, the PLAYERadevice contains
enhanced SMT support.
National Semiconductor’s FDDI TP-PMD Solutions consist
of two componentsÐthe DP83222 CYCLONETM Twisted
Pair FDDI Stream Cipher Device and the DP83223A
TWISTERTM Twisted Pair FDDI Transceiver Device.
For more information on the other devices of the chip set,
consult the appropriate datasheets and application notes.
1.1 FDDI 2-CHIP SET
DP83256/56-AP/57 PLAYERa
Device Physical Layer Controller
The PLAYERadevice implements the Physical Layer
(PHY) protocol as defined by the ANSI FDDI PHY X3T9.5
standard.
Features
YSingle chip FDDI Physical Layer (PHY) solution
YIntegrated Digital Clock Recovery Module provides en-
hanced tracking and greater lock acquisition range
YIntegrated Clock Generation Module provides all neces-
sary clock signals for an FDDI system from an external
12.5 MHz reference
YAlternate PMD Interface (DP83256-AP/57) supports
UTP twisted pair FDDI PMDs with no external clock re-
covery or clock generation functions required
YNo External Filter Components
YConnection Management (CMT) Support (LEM, TNE,
PCÐReact, CFÐReact, Auto Scrubbing)
YFull on-chip configuration switch
YLow Power CMOS-BIPOLAR design using a single 5V
supply
YFull duplex operation with through parity
YSeparate management interface (Control Bus)
YSelectable Parity on PHY-MAC Interface and Control
Bus Interface
YTwo levels of on-chip loopback
Y4B/5B encoder/decoder
YFraming logic
YElasticity Buffer, Repeat Filter, and Smoother
YLine state detector/generator
YSupports single attach stations, dual attach stations
and concentrators with no external logic
YDP83256/56-AP for SAS/DAS single path stations
YP83257 for SAS/DAS single/dual path stations
In addition, the DP83257 contains the additional PHYÐDa-
ta.request and PHYÐData.indicate ports required for con-
centrators and dual attach, dual path stations.
DP83266 MACSITM Device Media
Access Controller and System
Interface
The DP83266 Media Access Controller and System Inter-
face (MACSI) implements the ANSI X3T9.5 Standard Media
Access Control (MAC) protocol for operation in an FDDI
token ring and provides a comprehensive System Interface.
The MACSI device transmits, receives, repeats, and strips
tokens and frames. It produces and consumes optimized
data structures for efficient data transfer. Full duplex archi-
tecture with through parity allows diagnostic transmission
and self testing for error isolation in point-to-point connec-
tions.
The MACSI device includes the functionality of both the
DP83261 BMAC device and the DP83265 BSI-2 device with
additional enhancements for higher performance and reli-
ability.
Features
YOver 9 Kbytes of on-chip FIFO
Y5 DMA Channels (2 Output and 3 Input)
Y12.5 MHz to 33 MHz operation
YFull duplex operation with through parity
YReal-time VOID frame stripping indicator for bridges
YOn-chip Address bit swapping capability
Y32-bit wide Address/Data path with byte parity
YProgrammable transfer burst sizes of 4 or 8 32-bit
words
YReceive frame filtering services
YFrame-per-Page mode controllable on each DMA
channel
YDemultiplexed Addresses supported on ABus
YNew multicast address matching
YANSI X3T9.5 MAC standard defined ring service op-
tions
YSupports all FDDI Ring Scheduling Classes (Synchro-
nous, Asynchronous, etc.)
YSupports Individual, Group, Short, Long, and External
Addressing.
YGenerates Beacon, Claim, and Void frames
YExtensive ring and station statistics gathering
YExtension for MAC level bridging
YEnhanced SBus compatibility
YInterfaces to DRAMs or directly to system bus
YSupports frame Header/Info splitting
YProgrammable Big or Little Endian alignment
3
DP83222 CYCLONE Twisted Pair
FDDI Stream Cipher Device
General Description
The DP83222 CYCLONE Stream Cipher Scrambler/Des-
crambler Device is an integrated circuit designed to inter-
face directly with the serial bit streams of a Twisted Pair
FDDI PMD. The DP83222 is designed to be fully compatible
with the National Semiconductor FDDI Chip Sets, including
twisted pair FDDI Transceivers, such as the DP83223A
Twisted Pair Transceiver (TWISTER). The DP83222 re-
quires a 125 MHz Transmit Clock and corresponding Re-
ceive Clock for synchronous data scrambling and descram-
bling. The DP83222 is compliant with the ANSI X3T9.5
TP-PMD standard and is required for the reduction of EMI
emission over unshielded media. The DP83222 is specified
to work in conjunction with existing twisted pair transceiver
signalling schemes and enables high bandwidth transmis-
sion over Twisted Pair copper media.
Features
YEnables 100 Mbps FDDI signalling over Category 5
Unshielded Twisted Pair (UTP) cable and Type 1
Shielded Twisted Pair (STP)
YReduces EMI emissions over Twisted Pair media
YCompatible with ANSI X3T9.5 TP-PMD standard
YRequires a single a5V supply
YTransparent mode of operation
YFlexible NRZ and NRZI format options
YAdvanced BiCMOS process
YSignal Detect and Clock Detect inputs provided for en-
hanced functionality
YSuitable for Fiber Optic PMD replacement applications
DP83223A TWISTER High Speed
Networking Transceiver Device
General Description
The DP83223A Twisted Pair Transceiver is an integrated
circuit capable of driving and receiving either binary or
(MLT-3) encoded datastreams. The DP83223A Transceiver
is designed to interface directly with standards compliant
FDDI, 100BASE-TX or STS-3c ATM chip sets, allowing low
cost data links over copper based media. The DP83223A
allows links of up to 100 meters over both Shielded Twisted
Pair (STP) and datagrade Unshielded Twisted Pair (UTP) or
equivalent. The electrical performance of the DP83223A
meets or exceeds all performance parameters specified
in the ANSI X3T9.5 TP-PMD standard, the IEEE 802.3
100BASE-TX Fast Ethernet Specification and the ATM Fo-
rum 155 Mbps Twisted Pair PMD Interface Specification.
The DP83223A also provides important features such as
baseline restoration, TRI-STATEÉcapable transmit outputs,
and controlled transmit output edge rates (to reduce EMI
radiation) for both binary and MLT-3 modes of operation.
Features
YCompliant with ANSI X3T9.5 TP-PMD standard
YCompliant with IEEE 802.3 100BASE-TX Ethernet draft
standard
YCompliant with ATM Forum 155 Mbps Twisted Pair
Specification
YIntegrated baseline restoration circuit
YIntegrated transmitter and receiver with adaptive equali-
zation circuit
YProgrammable binary or MLT-3 operation
YIsolated TX and RX power supplies for minimum noise
coupling
YControlled transmit output edge rates for reduced EMI
YTRI-STATE capable current transmit outputs
YLoopback feature for board diagnostics
YProgrammable transmit voltage amplitude
4
2.0 Architecture Description
2.1 BLOCK OVERVIEW
The PLAYERadevice is comprised of six blocks: Clock
Recovery, Receiver, Configuration Switch, Transmitter, Sta-
tion Management (SMT) Support, and Clock Generation
Module as shown in
Figure 2-1
.
Clock Recovery
The Clock Recovery Module accepts a 125 Mbps NRZI data
stream from the external PMD receiver. It then provides the
extracted and synchronized data and clock to the Receiver
block.
The Clock Recovery Module performs the following opera-
tions:
#Locks to and tracks the incoming NRZI data stream
#Extracts data stream and synchronized 125 MHz clock
Receiver
During normal operation, the Receiver Block accepts serial
data as inputs at the rate of 125 Mbps from the Clock Re-
covery Module. During the Internal Loopback mode of oper-
ation, the Receiver Block accepts data directly from the
Transmitter Block.
The Receiver Block performs the following operations:
#Optionally converts the incoming data stream from NRZI
to NRZ.
#Decodes the data from 5B to 4B coding.
#Converts the serial bit stream into 10-bit bytes composed
of 8 bits data, 1 bit parity, and 1 bit control information.
#Compensates for the differences between the upstream
station clock and the local clocks.
#Decodes Line States.
#Detects link errors.
#Presents data symbol pairs (bytes) to the Configuration
Switch Block.
Configuration Switch
An FDDI station may be in one of three configurations: Iso-
late, Wrap or Thru. The Configuration Switch supports these
configurations by switching the transmitted and received
data paths between PLAYERadevices and one or more
MACSI devices.
The configuration switch is integrated into the PLAYERa
device, therefore no external logic is required for this func-
tion.
Setting the Configuration switch can be done explicitly via
the Control Bus Interface or it can be set automatically with
the CFÐReact SMT Support feature.
TL/F/11708 2
FIGURE 2-1. PLAYERaDevice Block Diagram
5
2.0 Architecture Description (Continued)
Transmitter
The Transmitter Block accepts 10-bit bytes composed of 8
bits data, 1 bit parity, and 1 bit control information from the
Configuration Switch.
The Transmitter Block performs the following operations:
#Encodes the data from 4B to 5B coding.
#Filters out code violations from the data stream.
#Generates Idle, Master, Halt, Quiet, or other user defined
symbol pairs upon request.
#Converts the data stream from NRZ to NRZI format for
transmission.
#Provides smoothing function when necessary.
During normal operation, the Transmitter Block presents se-
rial data to the PMD transmitter. While in Internal Loopback
mode, the Transmitter Block presents serial data to the Re-
ceiver Block. While in the External Loopback mode, the
Transmitter Block presents serial data to the Clock Recov-
ery Module.
Clock Generation Module
The Clock Generation Module is an integrated phase locked
loop that generates all of the required clock signals for the
PLAYERadevice and an FDDI system from a single
12.5 MHz reference.
The Clock Generation Module features:
#High precision clock timing generated from a single
12.5 MHz reference.
#Multiple precision phased (8 ns/16 ns) 12.5 MHz Local
Byte Clocks to eliminate timing skew in large multi-board
concentrator configurations.
#LBC timing which is insensitive to loading variations over
a wide range (20 pF to 70 pF) of LBC loads.
#A selectable dual frequency system clock.
#Low clock edge jitter, due to high VCO stability.
Station Management (SMT) Support
The Station Management Support Block provides a number
of useful features to simplify the implementation of the Con-
nection Management (CMT) portion of SMT.
These features eliminate the time critical CMT response
time constraints imposed by PCÐReact and CFÐReact
times.
Integrated counters and timers eliminate the need for addi-
tional external devices.
The following are the CMT features supported:
#PCÐReact
#CFÐReact
#Auto Scrubbing (TCF Timer)
#Timer, Idle Detection (TID Timer)
#Noise Event Counter (TNE Timer)
#Link Error Monitor (LEM Counter)
2.2 INTERFACES
The PLAYERadevice connects to other devices via five
functional interfaces: PMD Interface, PHY Port Interface,
Control Bus Interface, Clock Interface, and the Miscellane-
ous Interface.
PMD Interface
The PMD Interface connects the PLAYERadevice to a
standard FDDI Physical Media Connection such as a fiber
optic transceiver or a copper twisted pair transceiver. It is a
125 MHz full duplex serial connection.
The DP83256-AP and DP83257 PLAYERadevices contain
two PMD interfaces. The Primary PMD Interface should be
used for all PMD implementations that do not require an
external scrambler/descrambler function, clock recovery
function, or clock generation function, such as a Fiber Optic
or Shielded Twisted Pair (SDDI) PMD. The second, Alter-
nate PMD Interface can be used to support Unshielded
Twisted Pair (UTP) PMDs that require external scrambling,
and allows implementation with no external clock recovery
or clock generation functions required.
PHY Port Interface
The PHY Port Interface connects the PLAYERadevice to
one or more MAC devices and/or PLAYERadevices. Each
PHY Port Interface consists of two byte-wide interfaces, one
for PHY Request data input to the PLAYERadevice and
one for the PHY Indicate data output of the PLAYERade-
vice. Each byte-wide interface consists of a parity bit (odd
parity), a control bit, and two 4-bit symbols.
The DP83257 PLAYERadevice has two PHY Port Interfac-
es while the DP83256 has one PHY Port Interface.
Control Bus Interface
The Control Bus Interface connects the PLAYERadevice
to a wide variety of microprocessors and microcontrollers.
The Control Bus is an asynchronous interface which pro-
vides access to 64 8-bit registers which monitor and control
the behavior of the PLAYERadevice.
The Control Bus Interface allows a user to:
#Configure SMT features.
#Program the Configuration Switch.
#Enable/disable functions within the Transmitter and Re-
ceiver Blocks (i.e., NRZ/NRZI Encoder, Smoother, PHY
Request Data Parity, Line State Generation, Symbol pair
Injection, NRZ/NRZI Decoder, Cascade Mode, etc.).
The Control Bus Interface also can be used to perform the
following functions:
#Monitor Line States received.
#Monitor link errors detected by the Receiver Block.
#Monitor other error conditions.
Clock Interface
The Clock Interface is used to configure the Clock Genera-
tion Module and to provide the required clock signals for an
FDDI system.
The following clock signals are generated:
#5 phase offset 12.5 MHz Local Byte Clocks
#25 MHz Local Symbol Clock
#15.625 or 31.25 MHz System Clock
Miscellaneous Interface
The Miscellaneous Interface consists of:
#A reset signal.
#User definable sense signals.
#User definable enable signals.
#Synchronization for cascading PLAYERadevices (a
high-performance non-FDDI mode).
#Device Power and Ground pins.
6
3.0 Functional Description
The PLAYERadevice is comprised of six blocks: Clock
Recovery, Receiver, Transmitter, Configuration Switch,
Clock Generation, and Station Management Support.
3.1 CLOCK RECOVERY MODULE
The Clock Recovery Module accepts a 125 Mbps NRZI data
stream from the external PMD receiver. It then provides the
extracted and synchronized data and clock to the Receiver
block.
The Clock Recovery Module performs the following opera-
tions:
#Locks onto and tracks the incoming NRZI data stream
#Extracts the data stream and the synchronized 125 MHz
clock
The Clock Recovery Module is implemented using an ad-
vanced digital architecture that replaces sensitive analog
blocks with digital circuitry. This allows the PLAYERade-
vice to be manufactured to tighter tolerances since it is less
sensitive to processing variations that can adversely affect
analog circuits.
The Clock Recovery Module is comprised of 5 main func-
tional blocks:
Digital Phase Detector
Digital Phase Error Processor
Digital Loop Filter
Digital Phase to Frequency Converter
Frequency Controlled Oscillator
See
Figure 3-1
, Clock Recovery Module Block Diagram.
DIGITAL PHASE DETECTOR
The Digital Phase Detector has two main functions: phase
error detection and data recovery.
Phase error detection is accomplished by a digital circuit
that compares the input data (PMID) to an internal phase-
locked 125 MHz reference clock and generates a pair of
error signals. The first signal is a pulse whose width is equal
to the phase error between the input data and a reference
clock and the second signal isa4nsreference pulse.
These signals are fed into the Digital Phase Error Processor
block.
The data recovery function converts the incoming encoded
data stream (PMID) into synchronized data and clock sig-
nals. When the circuit is in lock the rising edge of the recov-
ered clock is exactly centered in the recovered data bit cell.
The digital phase detector uses a common path for phase
error detection and data recovery so as to minimize clock
Static Alignment Error (SAE). Phase error averaging is also
included so that phase errors generated by positive and
negative PMID edges equally affect the clock recovery cir-
cuit. This greatly improves the immunity to Duty Cycle Dis-
tortion (DCD) in the data recovery circuit.
DIGITAL PHASE ERROR PROCESSOR
The Digital Phase Error Processor is responsible for sam-
pling the Phase Detector’s phase error outputs and produc-
ing two digital outputs that indicate to the digital loop filter
how to adjust for a difference between the data phase and
reference phases.
The Phase Error Processor is designed to eliminate the ef-
fects of different clock edge densities between data sym-
bols and the various line state symbols on the PLL’s loop
gain.
TL/F/11708 3
FIGURE 3-1. Clock Recovery Module Block Diagram
7
3.0 Functional Description (Continued)
Since the loop gain is held constant regardless of the in-
coming signal edge density, PLL characteristics such as jit-
ter, acquisition rate, locking range etc., are deterministic and
show minimal spread under various operating environments.
The phase error processor also automatically puts the loop
in open-loop-mode when the incoming data stream contains
abnormal low edge rates. When the PLL is in open-loop-
mode, no update is made to the PLL’s filter variables in the
filter block. The PLL can then use the pretrained frequency
and phase contents to perform data recovery. Since the
loop is implemented digitally, these values (the frequency
and phase variables) are retained. The resolution of the fre-
quency variable is about 1.3 ppm of the incoming frequency.
The resolution of the phase variable is about 40 ps.
DIGITAL LOOP FILTER
The digital loop filter emulates a 1-pole, 1-zero filter and
uses an automatic acquisition speed control circuit to dy-
namically adjust loop parameters.
The digital loop filter takes the phase error indicator signals
Data Valid and Up/Down from the Phase Error processor
and accumulates errors over a few cycles before passing on
the Data Valid and Up/Down signals to the Phase Error to
Frequency converter.
The filter has 4 sets of bandwidth and damping parameters
which are switched dynamically by an acquisition control
circuit. The input Signal Detect (SD) starts the sequence
and, thereafter, no user programming is required to finish
the sequence.
At the completion of the locking sequence, the loop has the
narrowest bandwidth such that the loop produces minimal
recovered clock jitter. The PLL can track an incoming fre-
quency offset of approximately g200 ppm. After the acqui-
sition sequence, the equivalent natural frequency of the
loop is reduced to about 7 kHz (g56 ppm) of frequency
offset.
The automatic tracking mechanism allows the loop to quick-
ly lock onto the initial data stream for data recovery (typical-
ly less than 10 ms) and yet produce very little recovered
clock jitter.
PHASE ERROR TO FREQUENCY CONVERTER (O–F)
The Phase Error to Frequency Converter takes the Data
Valid and Up/Down signals modified by the Digital Loop
Filter and converts them to triangle waves. The frequency of
the triangle waves is then used to control the Frequency
Controlled Oscillator’s (FCO) 250 MHz oscillations.
Each valid Up or Down signal causes a partial 7-bit counter
(using only 96 counts) to increment or decrement at the
OF converter’s clock rate of 15.625 MHz (250 MHz/16).
When the Data Valid signal is not asserted, the counter
holds count.
The counter value is used to produce 3 triangle waves that
are offset in phase by 120 degrees. This is done with a
special Pulse Density Modulator waveform synthesizer
which takes the place of a traditional Digital-Analog convert-
er. The frequency of the triangle waves tells the Frequency
Controlled Oscillator how much to adjust oscillation. The
phase relationships (leading or lagging) between the 3 sig-
nals indicates the direction of change.
The minimum frequency of the triangle waves is 0 and cor-
responds to the case when the PLL is in perfect lock with
the incoming signal.
The maximum frequency that the OF converter can pro-
duce determines the locking range of the PLL. In this case
the maximum frequency of each triangle wave is 162.76
kHz, which is produced when the OF converter gets a
continuous count in one direction that is valid every O–F
converter clock cycle of 15.625 MHz (250 MHz/16). The
triangle waves have an amplitude resolution of 48 digital
steps, so a full rising and falling period takes 96 counts
which produces a maximum frequency of 162.76 kHz
(1/(1/15.625 kHz *96)).
The 96 digital counts of the triangle waves also lead to a
very fine PLL phase resolution of 42 ps (4 ns/96 counts).
This high phase resolution is achieved using very low fre-
quency signals, in contrast to a standard PLL which must
operate at significantly higher frequencies than the data be-
ing tracked to achieve such high phase resolution.
FREQUENCY CONTROLLED OSCILLATOR (FCO)
The frequency controlled oscillator produces a 250 MHz
clock that, when divided by 2, is phase locked to the incom-
ing data’s clock.
The FCO uses three 250 MHz reference clock signals from
the Clock Generation Module and three 0 Hz to 162.76 kHz
error clock signals from the Phase Error to Frequency Con-
verter as inputs. Each signal in a triplet is 120 degrees
phase shifted from the next.
Each corresponding pair (one 250 MHz and one error sig-
nal) of signals is mixed together using an amplitude switch-
ing modulator, with the error signal modulating the refer-
ence. All of the outputs are then summed together to pro-
duce the final 250 MHz afmphase locked clock signal,
where fmis the error frequency.
8
3.0 Functional Description (Continued)
3.2 RECEIVER BLOCK
During normal operation, the Receiver Block accepts serial
data input at the rate of 125 Mbps from the Clock Recovery
Module. During the Internal Loopback mode of operation,
the Receiver Block accepts input data from the Transmitter
Block.
The Receiver Block performs the following operations:
#Optionally converts the incoming data stream from NRZI
to NRZ.
#Decodes the data from 5B to 4B coding.
#Converts the serial bit stream into the National byte-wide
code.
#Compensates for the differences between the upstream
station clock and the local clock.
#Decodes Line States.
#Detects link errors.
#Presents data symbol pairs to the Configuration Switch
Block.
The Receiver Block consists of the following functional
blocks:
NRZI to NRZ Decoder
Shift Register
Framing Logic
Symbol Decoder
Line State Detector
Elasticity Buffer
Link Error Detector
See
Figure 3-2.
NRZI TO NRZ DECODER
The NRZI to NRZ Decoder converts Non-Return-To-Zero-
Invert-On-Ones data to Non-Return-To-Zero format.
NRZ format data is the natural data format that the receiver
block utilizes internally, so this function is required when the
standard NRZI format data is fed into the device. The re-
ceiver block can bypass this conversion function in the case
where an alternate data source outputs NRZ format data.
This function can be enabled and disabled through bit 7
(RNRZ) of the Mode Register (MR). When the bit is cleared,
it converts the incoming bit stream from NRZI to NRZ. This
is the normal configuration required. When the bit is set, the
incoming NRZ bit stream is passed unchanged.
SHIFT REGISTER
The Shift Register converts the serial bit stream into sym-
bol-wide data for the 5B/4B Decoder.
The Shift Register also provides byte-wide data for the
Framing Logic.
FRAMING LOGIC
The Framing Logic performs the Framing function by detect-
ing the beginning of a frame or the Halt-Halt or Halt-Quiet
symbol pair.
The J-K symbol pair (11000 10001) indicates the beginning
of a frame during normal operation. The Halt-Halt (00100
00100) and Halt-Quiet (00100 00000) symbol pairs are de-
tected for Connection Management (CMT).
TL/F/11708 4
FIGURE 3-2. Receiver Block Diagram
9
3.0 Functional Description (Continued)
Framing may be temporarily suspended (i.e. framing hold),
in order to maintain data integrity.
Detecting JK
The JK symbol pair can be used to detect the beginning of a
frame during Active Line State (ALS) and Idle Line State
(ILS) conditions.
While the Line State Detector indicates Idle Line State the
receiver ‘‘reframes’’ upon detecting a JK symbol pair and
enters the Active Line State.
During Active Line State, acceptance of a JK symbol (re-
framing) is allowed for any on-boundary JK which is detect-
ed at least 1.5 byte times after the previous JK.
During Active Line State, once reframed on a JK, a subse-
quent off-boundary JK is ignored, even if it is detected be-
yond 1.5 byte times after the previous JK.
During Active Line State, an Idle or Ending Delimiter (T)
symbol will allow reframing on any subsequent JK, if a JK is
detected at least 1.5 byte times after the previous JK.
Detecting HALT-HALT AND HALT-QUIET
During Idle Line State, the detection of a Halt-Halt, or Halt-
Quiet symbol pair will still allow the reframing of any subse-
quent on-boundary JK.
Once a JK is detected during Active Line State, off-bounda-
ry Halt-Halt, or Halt-Quiet symbol pairs are ignored until the
Elasticity Buffer (EB) has an opportunity to recenter. They
are treated as violations.
After recentering on a Halt-Halt, or Halt-Quiet symbol pair,
all off boundary Halt-Halt or Halt-Quiet symbol pairs are ig-
nored until the EB has a chance to recenter during a line
state other than Active Line State (which may be as long as
2.8 byte times).
SYMBOL DECODER
The Symbol Decoder is a two level system. The first level is
a 5-bit to 4-bit converter, and the second level is a 4-bit
symbol pair to byte-wide code converter.
The first level latches the received 5-bit symbols and de-
codes them into 4-bit symbols. Symbols are decoded into
two types: data and control. The 4-bit symbols are sent to
the Line State Detector and the second level of the Symbol
Decoder. See Table 3-1 for the 5B/4B Symbol Decoding
list.
The second level translates two symbols from the 5B/4B
converter and the line state information from the Line State
Detector into the National byte-wide code.
LINE STATE DETECTOR
The ANSI X3T9.5 FDDI Physical Layer (PHY) standard
specifies eight Line States that the Physical Layer can
transmit. These Line States are used in the Connection
Management process. They are also used to indicate data
within a frame during normal operation.
The Line States are reported through the Current Receive
State Register (CRSR), Receive Condition Register A
(RCRA), and Receive Condition Register B (RCRB).
TABLE 3-1. 5B/4B Symbol Decoding
Symbol Incoming 5B Decoded 4B
0 11110 0000
1 01001 0001
2 10100 0010
3 10101 0011
4 01010 0100
5 01011 0101
6 01110 0110
7 01111 0111
8 10010 1000
9 10011 1001
A 10110 1010
B 10111 1011
C 11010 1100
D 11011 1101
E 11100 1110
F 11101 1111
I (Idle) 11111 1010
H (Halt) 00100 0001
JK (Starting 11000 and 1101
Delimiter) 10001
T (Ending 01101 0101
Delimiter)
R (Reset) 00111 0110
S (Set) 11001 0111
Q (Quiet) 00000 0010
V (Violation) 00001 0010
V 00010 0010
V 00011 0010
V 00101 0010
V 00110 0010
V 01000 0010
V 01100 0010
V 10000 0010
Note: VÊdenotes PHY Invalid or an Elasticity Buffer stuff byte
IÊdenotes Idle symbol in ILS or an Elasticity Buffer stuff byte
LINE STATES DESCRIPTION
Active Line State
The Line State Detector recognizes the incoming data to be
in the Active Line State upon the reception of the Starting
Delimiter (JK symbol pair).
The Line State Detector continues to indicate Active Line
State while receiving data symbols, Ending Delimiter (T
symbols), and Frame Status symbols (R and S) after the JK
symbol pair.
Idle Line State
The Line State Detector recognizes the incoming data to be
in the Idle Line State upon the reception of 2 Idle symbol
pairs nominally (plus up to 9 bits of 1 in start up cases).
Idle Line State indicates the preamble of a frame or the lack
of frame transmission during normal operation. Idle Line
State is also used in the handshake sequence of the PHY
Connection Management process.
10
3.0 Functional Description (Continued)
Super Idle Line State
The Line State Detector recognizes the incoming data to be
in the Super Idle Line State upon the reception of 8 consec-
utive Idle symbol pairs nominally (plus 1 symbol pair).
The Super Idle Line State is used to insure synchronization
of PCM signalling.
No Signal Detect
The Line State Detector recognizes the incoming data to be
in the No Signal Detect state upon the deassertion of the
Signal Detect signal or lack of internal clock detect from the
Clock Recovery Module, and reception of 8 Quiet symbol
pairs nominally. No Signal Detect indicates that the incom-
ing link is inactive. This is the same as receiving Quiet Line
State (QLS).
Master Line State
The Line State Detector recognizes the incoming data to be
in the Master Line State upon the reception of eight consec-
utive Halt-Quiet symbol pairs nominally (plus up to 2 symbol
pairs in start up cases).
The Master Line State is used in the handshaking sequence
of the PHY Connection Management process.
Halt Line State
The Line State Detector recognizes the incoming data to be
in the Halt Line State upon the reception of eight consecu-
tive Halt symbol pairs nominally (plus up to 2 symbol pairs in
start up cases).
The Halt Line State is used in the handshaking sequence of
the PHY Connection Management process.
Quiet Line State
The Line State Detector recognizes the incoming data to be
in the Quiet Line State upon the reception of eight consecu-
tive Quiet symbol pairs nominally (plus up to 9 bits of 0 in
start up cases).
The Quiet Line State is used in the handshaking sequence
of the PHY Connection Management process.
Noise Line State
The Line State Detector recognizes the incoming data to be
in the Noise Line State upon the reception of 16 noise sym-
bol pairs without entering any known line state.
The Noise Line State indicates that data is not being re-
ceived correctly.
Line State Unknown
The Line State Detector recognizes the incoming data to be
in the Line State Unknown state upon the reception of 1
inconsistent symbol pair (i.e. data that is not expected). This
may signify the beginning of a new line state.
Line State Unknown indicates that data is not being re-
ceived correctly. If the condition persists the Noise Line
State (NLS) may be entered.
ELASTICITY BUFFER
The Elasticity Buffer performs the function of a ‘‘variable
depth’’ FIFO to compensate for phase and frequency clock
skews between the Receive Clock (RXCg) and the Local
Byte Clock (LBC).
Bit 5 (EBOU) of the Receive Condition Register B (RCRB) is
set to 1 to indicate an error condition when the Elasticity
Buffer cannot compensate for the clock skew.
The Elasticity Buffer will support a maximum clock skew of
50 ppm with a maximum packet length of 4500 bytes.
To make up for the accumulation of frequency disparity be-
tween the two clocks, the Elasticity Buffer will insert or de-
lete Idle symbol pairs in the preamble. Data is written into
the byte-wide registers of the Elasticity Buffer with the Re-
ceive Clock, while data is read from the registers with the
Local Byte Clock.
The Elasticity Buffer will recenter (i.e. set the read and write
pointers to a predetermined distance from each other) upon
the detection of a JK or every four byte times during PHY
Invalid (i.e. MLS, HLS, QLS, NLS, NSD) and Idle Line State.
The Elasticity Buffer is designed such that a given register
cannot be written and read simultaneously under normal op-
erating conditions. To avoid metastability problems, the EB
overflow event is flagged and the data is tagged before the
over/under run actually occurs.
LINK ERROR DETECTOR
The Link Error Detector provides continuous monitoring of
an active link (i.e. during Active and Idle Line States) to
insure that it does not exceed the maximum Bit Error Rate
requirement as set by the ANSI standard for a station to
remain on the ring.
Upon detecting a link error, the internal 8-bit Link Error Mon-
itor Counter is decremented. The start value for the Link
Error Monitor Counter is programmed through the Link Error
Threshold Register (LETR). When the Link Error Monitor
Counter reaches zero, bit 4 (LEMT) of the Interrupt Condi-
tion Register (ICR) is set to 1. The current value of the Link
Error Monitor Counter can be read through the Current Link
Error Count Register (CLECR). For higher error rates the
current value is an approximate count because the counter
rolls over.
There are two ways to monitor Link Error Rate: polling and
interrupt.
Polling
The Link Error Monitor Counter can be set to a large value,
like FF. This will allow for the greatest time between polling
the register. This start value is programmed through the Link
Error Threshold Register (LETR).
Upon detecting a link error, the Line Error Monitor Counter
is decremented.
The Host System reads the current value of the Link Error
Monitor Counter via the Current Link Error Count Register
(CLECR). The Counter is then reset to FF.
Interrupt
The Link Error Monitor Counter can be set to a small value,
like 5 to 10. This start value is programmed through the Link
Error Threshold Register (LETR).
Upon detecting a link error, the Line Error Monitor Counter
is decremented. When the counter reaches zero, bit 4
(LEMT) of the Interrupt Condition Register (ICR) is set to 1,
and the interrupt signal goes low, interrupting the Host Sys-
tem.
Miscellaneous Items
When bit 0 (RUN) of the Mode Register (MR) is set to zero,
or when the PLAYERadevice is reset through the Reset
pin (ERST), the internal signal detect line is internally
forced to zero and the Line State Detector is set to Line
State Unknown and No Signal Detect.
11
3.0 Functional Description (Continued)
3.3 TRANSMITTER BLOCK
The Transmitter Block accepts 10-bit bytes consisting of
8 bits data, 1 bit parity, and 1 bit control information, from
the Configuration Switch.
The Transmitter Block performs the following operations:
#Encodes the data from 4B to 5B coding.
#Filters out code violations from the data stream.
#Is capable of generating Idle, Master, Halt, Quiet, or oth-
er user defined symbol pairs.
#Converts the data stream from NRZ to NRZI for trans-
mission.
#Serializes data.
During normal operation, the Transmitter Block presents se-
rial data to a PMD transmitter.
While in Internal Loopback mode, the Transmitter Block
presents serial data to the Receiver Block. While in the Ex-
ternal Loopback mode, the Transmitter Block presents seri-
al data to the Clock Recovery Module.
The Transmitter Block consists of the following functional
blocks:
Data Registers
Parity Checker
4B/5B Encoder
Repeat Filter
Smoother
Line State Generator
Injection Control Logic
Shift Register
NRZ to NRZI Encoder
See
Figure 3-3
, Transmitter Block Diagram.
TL/F/11708 5
FIGURE 3-3. Transmitter Block Diagram
12
3.0 Functional Description (Continued)
DATA REGISTERS
Data from the Configuration Switch is stored in the Data
Registers. The 10-bit byte-wide data consists of a parity bit,
a control bit, and two 4-bit data symbols as shown below.
b9 b8 b7 b0
Parity Bit Control Bit Data Bits
FIGURE 3-4. Byte-Wide Data
The parity is odd parity. The control bit determines whether
the Data bits represent Data or Control information. When
the control bit is 0 the Data field is interpreted as data and
when it is 1 the field is interpreted as control information
according to the National Semiconductor control codes.
PARITY CHECKER
The Parity Checker verifies that the parity bit in the Data
Register represents odd parity (i.e. odd number of 1s).
The parity is enabled and disabled through bit 6 (PRDPE) of
the Current Transmit State Register (CTSR).
If a parity error occurs, the Parity Checker will set bit 0 (DPE)
in the Interrupt Condition Register (ICR) and report the error
to the Repeat Filter.
4B/5B ENCODER
The 4B/5B Encoder converts the two 4-bit data symbols
from the Configuration Switch into their respective 5-bit
codes.
See Table 3-2 for the Symbol Encoding list.
TABLE 3-2. 4B/5B Symbol Encoding
Symbol 4B Code 5B Code
0 0000 11110
1 0001 01001
2 0010 10100
3 0011 10101
4 0100 01010
5 0101 01011
6 0110 01110
7 0111 01111
8 1000 10010
9 1001 10011
A 1010 10110
B 1011 10111
C 1100 11010
D 1101 11011
E 1110 11100
F 1111 11101
N 0000 11110 or
11111
JK (Starting 1101 11000 and
Delimiter) 10001
T (Ending 0100 or 01101
Delimiter) 0101
R (Reset) 0110 00111
Note: The upper group of symbols are sent with the Control/Data pin set to
Data, while the bottom grouping of symbols are sent with the Control/Data
pin set to Control.
REPEAT FILTER
The Repeat Filter is used to prevent the propagation of
code violations to the downstream station.
Upon receiving violations in data frames, the Repeat Filter
replaces them with two Halt symbol pairs followed by Idle
symbols. Thus the code violations are isolated and recov-
ered at each link and will not be propagated throughout the
entire ring.
13
3.0 Functional Description (Continued)
TL/F/11708 6
FIGURE 3-5. Repeat Filter State Diagram
Note: Inputs to the Repeat Filter state machine are shown above the transition lines, while outputs from the state machine are shown below the transition lines.
Note: Abbreviations used in the Repeat Filter State Diagram are shown in Table 3-3.
14
3.0 Functional Description (Continued)
TABLE 3-3. Abbreviations used in the
Repeat Filter State Diagram
FÐIDLE: Force IdleÐtrue when not in Active
Transmit Mode.
W: Represents the symbols R, or S, or T
ETPARITY: Parity error
nn : Data symbols (for C e0 in the PHY-MAC
interface)
N: Data portion of a control and data symbol
mixture
X: Any symbol (i.e. don’t care)
VÊ: Violation symbols or symbols inserted by
the Receiver Block
IÊ: Idle symbols or symbols inserted by the
Receiver Block
ALSZILSZ: Active Line State or Idle Line State (i.e.
PHY Invalid)
EALSZILSZ: Not in Active Line State nor in Idle Line
State (i.e. PHY Valid)
H: Halt Symbol
R: Reset Symbol
S: Set Symbol
T: Frame ending delimiter
JK: Frame start delimiter
I: Idle symbol (Preamble)
V: Code violations
The Repeat Filter complies with the FDDI standard by ob-
serving the following (see
Figure 3-5
):
1. In Repeat State, violations cause transitions to Halt State
and two Halt symbol pairs are transmitted (unless JK or Ix
occurs) followed by transition to Idle State.
2. When Ix is encountered, the Repeat Filter goes to the Idle
State, during which Idle symbol pairs are transmitted until
a JK is encountered.
3. The Repeat Filter goes to the Repeat State following a JK
from any state.
The END State, which is not part of the FDDI PHY standard,
allows an R or S prior to a T within a frame to be recognized
as a violation. It also allows NT to end a frame as opposed
to being treated as a violation.
SMOOTHER
The Smoother is used to keep the preamble length of a
frame to a minimum of 6 Idle symbol pairs.
Idle symbols in the preamble of a frame may have been
added or deleted by each station to compensate for the
difference between the Receive Clock and its Local Clock.
The preamble needs to be maintained at a minimum length
to allow stations enough time to complete processing of one
frame and prepare to receive another. Without the Smooth-
er function, the minimum preamble length (6 Idle symbol
pairs) cannot be maintained as several stations may con-
secutively delete Idle symbols.
The Smoother attempts to keep the number of Idle symbol
pairs in the preamble at 7 by:
#Deleting an Idle symbol pair in preambles which have
more than 7 Idle symbol pairs
and/or
#Inserting an idle symbol pair in preambles which have
less than 7 idle symbol pairs (i.e. Extend State).
The Smoother Counter starts counting upon detecting an
Idle symbol pair. It stops counting upon detecting a JK sym-
bol pair.
Figure 3-6
describes the Smoother state diagram.
15
3.0 Functional Description (Continued)
LINE STATE GENERATOR
The Line State Generator allows the transmission of the
PHY Request data and can also generate and transmit Idle,
Master, Halt, or Quiet symbol pairs which can be used to
implement the Connection Management procedures as
specified in the FDDI Station Management (SMT) standard
document.
The Line State Generator is programmed through Transmit
bits 0 to 2 (TMk2:0l) of the Current Transmit State Regis-
ter (CTSR).
Based on the setting of these bits, the Transmitter Block
operates in a Transmit Mode where the Line State Genera-
tor overwrites the Repeat Filter and Smoother outputs.
See INJECTION CONTROL LOGIC section for a listing of
the injection Transmit Modes.
Table 3-4 describes the Transmit Modes.
TABLE 3-4. Transmit Modes
Transit Mode Behavior
Active Transmit Mode Transmit data that comes
from Configuration Switch
Off Transmit Mode Transmit Quiet symbol
pairs and disable the PMD
Transmitter
Idle Transmit Mode Transmit Idle symbol pairs
Master Transmit Mode Transmit Halt-Quiet
symbol pairs
Quiet Transmit Mode Transmit Quiet symbol
pairs
Reserved Transmit Mode Reserved for future use. If
Mode selected, Quiet
symbol pairs will be
transmitted.
Halt Transmit Mode Transmit Halt Symbol
pairs
Notes: TL/F/11708 7
SE: Smoother Enable
C: Preamble Counter
FÐIDLE: ForceÐIdle (Stop or ATM)
Xn: Current Byte
Xn–1: Previous Byte
W: RST
FIGURE 3-6. Smoother State Diagram
16
3.0 Functional Description (Continued)
INJECTION CONTROL LOGIC
The Injection Control Logic replaces the data stream with a
programmable symbol pair. This function is used to transmit
data other than the normal data frame or Line States. The
injection modes can be used for station diagnostic software.
The Injection Symbols overwrite the Line State Generator
(Transmit Modes) and the Repeat Filter and Smoother out-
puts.
These programmable symbol pairs are stored in the Injec-
tion Symbol Register A (ISRA) and Injection Symbol Regis-
ter B (ISRB). The Injection Threshold Register (IJTR) deter-
mines where the Injection Symbol pair will replace the data
symbols.
The Injection Control Logic is programmed through the bits
0 and 1 (ICk1:0l) of the Current Transmit State Register
(CTSR) to one of the following Injection Modes (see
Figure
3-7
):
1. No Injection (i.e. normal operation)
2. One Shot
3. Periodic
4. Continuous
In the No Injection mode, the data stream is transmitted
unchanged.
In the One Shot mode, ISRA and ISRB are injected once on
the nth byte after a JK, where n is the programmed value
specified in the Injection Threshold Register.
In the Periodic mode, ISRA and ISRB are injected every nth
symbol.
In the Continuous mode, all data symbols are replaced with
the content of ISRA and ISRB. This is the same as periodic
mode with IJTRe0.
SHIFT REGISTER
The Shift Register converts encoded parallel data to serial
data. The parallel data is clocked into the Shift Register by
the Local Byte Clock (LBC1), and clocked out by the Trans-
mit Bit Clock (TXCg) (externally available on the DP83257.)
NRZ TO NRZI ENCODER
The NRZ to NRZI Encoder converts the serial Non-Return-
To-Zero data to Non-Return-To-Zero-Invert-On-One format.
This function can be enabled and disabled through bit 6
(TNRZ) of the Mode Register (MR). When programmed to
‘‘0’’, it converts the bit stream from NRZ to NRZI. When
programmed to ‘‘1’’, the bit stream is transmitted NRZ.
One Shot (Notes 1,3)
TL/F/11708 8
Periodic (Notes 2,3)
TL/F/11708 9
Continuous (Note 3)
TL/F/11708 10
Note 1: In one shot, when ne0, the JK is replaced
Note 2: In periodic, when ne0, all symbols are replaced.
Note 3: Max value on ne255.
FIGURE 3-7. Injection Modes
17
3.0 Functional Description (Continued)
3.4 CONFIGURATION SWITCH
The Configuration Switch consists of a set of multiplexers
and latches which allow the PLAYERadevice to configure
the data paths without any external logic. The Configuration
Switch is controlled through the Configuration Register
(CR).
The Configuration Switch has four internal buses: the
AÐRequest bus, the BÐRequest bus, the Receive bus, and
the PHYÐInvalid bus. The two Request buses can be driv-
en by external input data connected to the external PHY
Port interface. The Receive bus is internally connected to
the Receive Block of the PLAYERadevice, while the
PHYÐInvalid bus has a fixed 10-bit SMT PHY Invalid con-
nection (LSU) pattern (1 0011 1010), which is useful during
the connection process.
The configuration switch also has three internal multiplex-
ers, each can select any of the four buses to connect to its
respective data path. The first two are PHY Port interface
output data paths, AÐIndicate and BÐIndicate, that can
drive output data paths of the external PHY Port interface.
The third output data path is connected internally to the
Transmit Block.
The Configuration Switch is the same on the DP83256 de-
vice, the DP83256-AP device, and the DP83257 device.
However, the DP83257 has two PHY Port interfaces con-
nected to the Configuration Switch, whereas the DP83256
and DP83256-AP have one set of PHY port interfaces. The
DP83257 uses the AÐRequest and AÐIndicate paths as
one PHY Port interface and the BÐRequest and BÐIndi-
cate paths as the other PHY Port interface (See
Figure 3-8
).
The DP83256 and DP83256-AP, having one port interface,
use the BÐRequest and AÐIndicate paths as its external
port. The AÐRequest and BÐIndicate paths of the
DP83256 and DP83256-AP are null connections and are not
used by the device (See
Figure 3-9
).
TL/F/11708 11
FIGURE 3-8. Configuration Switch
Block Diagram for DP83257
TL/F/11708 12
FIGURE 3-9. Configuration Switch
Block Diagram for DP83256
and DP83256-AP
18
3.0 Functional Description (Continued)
STATION CONFIGURATIONS
Single Attach Station (SAS)
The Single Attach Station can be connected to either the
Primary or Secondary ring via a Concentrator. Only 1 MAC
is needed in a SAS.
The DP83256, DP83256-AP, and DP83257 can be used in a
Single Attach Station. The DP83256 and DP83256-AP can
be connected to the MAC via its only PHY Port interface.
The DP83257 can be connected to the MAC via either one
of its 2 PHY Port Interfaces.
See
Figure 3-10
and
Figure 3-11
.
TL/F/11708 13
FIGURE 3-10. Single Attach Station
Using the DP83256 or DP83256-AP
TL/F/11708 14
FIGURE 3-11. Single Attachment Station (SAS)
Using the DP83257
Dual Attach Station(DAS)
A Dual Attach Station can be connected directly to the dual
ring, or, optionally to a concentrator. There are two types of
Dual Attach Stations: DAS with a single MAC and DAS with
two MAC layers. See
Figure 3-12
and
Figure 3-13
.
Two DP83256 or DP83256-AP parts can be connected to-
gether to build a Dual Attach Station, however this configu-
ration does not support the optional ThruÐB configuration.
When the optional ThruÐB configuration is desired, it is rec-
ommended that the DP83257 be used.
A DAS with a single MAC and two paths can be configured
as follows (see
Figure 3-12
):
#B Indicate data of PHYÐA is connected to A Request
input of PHYÐB. BÐRequest input of PHYÐA is con-
nected to A Indicate output of PHYÐB.
#The MAC can be connected to either the A Request in-
put and the A Indicate output of PHYÐAortheBRe-
quest input and the B Indicate output of PHYÐB.
A DAS with a single MAC and one path using the DP83256
or DP83256-AP can be configured as follows (see
Figure 3-
13
):
#BÐRequest input of PHYÐA is connected to A Indicate
output of PHYÐB.
#The MAC is connected to the B Request input of
PHYÐB and the AÐIndicate output of PHYÐA.
A DAS with dual MACs can be configured as follows (see
Figure 3-14
):
#B Indicate data of PHYÐA is connected to A Request
input of PHYÐB. BÐRequest input of PHYÐA is con-
nected to A Indicate output of PHYÐB.
#MACÐ1 is connected to the BÐIndicate output and the
BÐRequest Input of PHYÐB.
#MACÐ2 is connected to the AÐIndicate output and the
AÐRequest Input of PHYÐA.
19
3.0 Functional Description (Continued)
TL/F/11708 15
FIGURE 3-12. Dual Attachment Station (DAS), Single MAC (DP83257)
TL/F/11708 16
FIGURE 3-13. Dual Attachment Station (DAS), Single MAC (DP83256/56-AP)
TL/F/11708 17
FIGURE 3-14. Dual Attachment Station (DAS), Dual MACs
20
3.0 Functional Description (Continued)
CONCENTRATOR CONFIGURATIONS
There are 2 types of concentrators: Single Attach and Dual
Attach. These concentrators can be designed with or with-
out MAC(s). The configuration is determined based upon its
type and the number of active MACs in the concentrator.
Using the PLAYERadevice, a concentrator can be built
with many different configurations without any external log-
ic.
The DP83256, DP83256-AP, and DP83257 can be used to
build a Single Attach concentrator.
See Application Note AN-675, Designing FDDI concentra-
tors and Application Note AN-741, Differentiating FDDI con-
centrators for further information.
Concepts
A concentrator is comprised of 2 parts: the Dual Ring Con-
nect portion and the Master Ports.
The Dual Ring Connection portion connects the concentra-
tor to the dual ring directly or to another concentrator. If the
concentrator is connected directly to the dual ring, it is a
part of the ‘‘Dual Ring of Trees’’. If the concentrator is con-
nected to another concentrator, it is a ‘‘Branch’’ of the
‘‘Dual Ring of Trees’’.
The Master Ports connect the concentrator to its ‘‘Slaves’’,
or S-class, Single Attach connections. A slave could be a
Single Attach Station or another concentrator (thus forming
another Branch of the Dual Ring Tree).
When a MAC in a concentrator is connected to the primary
or secondary ring, it is required to be situated at the exit port
of that ring (i.e. its PHÐIND is connected to the IND Inter-
face of the last Master Port in the concentrator (PHYÐMn)
that is connected to that ring).
A concentrator can have two MACs, one connected to the
primary ring and one to the secondary ring. In addition, rov-
ing MACs can be included in the concentrator configuration.
A roving MAC can be used to test the stations connected to
the concentrator before allowing them to join the dual ring.
This may require external multiplexers, if used in conjunc-
tion with two other MAC layers.
Single Attach Concentrator
A Single Attach concentrator is a concentrator that has only
one PHY at the dual ring connect side. It cannot, therefore,
be connected directly to the dual ring. A Single Attach con-
centrator is a branch to the dual ring tree. It is connected to
the ring as a slave of another concentrator.
Multiple Single Attach concentrators can be connected to-
gether hierarchically to build a multiple levels of branches in
a dual ring.
The Single Attach concentrator can be connected to either
the primary or secondary ring depending on the connection
with its concentrator (the concentrator that it is connected
to as a slave).
Figure 3-15
shows a Single Attach concentrator with a sin-
gle MAC.
Dual Attach Concentrator
A Dual Attach concentrator is a concentrator that has two
PHYs on the dual ring connect side. It is connected directly
to the dual ring and is a part of the dual ring tree.
The Dual Attach concentrator is connected to both the pri-
mary and secondary rings.
Dual Attach Concentrator with Single MAC
Figure 3-16
shows a Dual Attach concentrator with a single
MAC.
Because the concentrator has one MAC, it can only transmit
and receive frames on the ring to which the MAC is con-
nected. The concentrator can only repeat frames on the
other ring.
Dual Attach Concentrator with Dual MACs
Figure 3-17
shows a Dual Attach concentrator with dual
MACs.
Because the concentrator has two MACs, it can transmit
and receive frames on both the primary and secondary
rings.
21
3.0 Functional Description (Continued)
TL/F/11708 18
FIGURE 3-15. Single Attach Concentrator (SAC), Single MAC
TL/F/11708 19
FIGURE 3-16. Dual Attach Concentrator (DAC), Single MAC
TL/F/11708 20
FIGURE 3-17. Dual Attach Concentrator (DAC), Dual MACs
22
3.0 Functional Description (Continued)
3.5 CLOCK GENERATION MODULE
The Clock Generation Module is an integrated phase locked
loop that generates all of the required clock signals for the
PLAYERadevice and the rest of an FDDI system from a
single 12.5 MHz reference.
The Clock Generation Module features:
#High precision clock timing generated from a single
12.5 MHz reference.
#Multiple precision phased (8 ns/16 ns) 12.5 MHz Local
Byte Clocks to eliminate timing skew in large multi-board
concentrator configurations.
#LBC timing which is insensitive to loading variations over
a wide range (20 pF to 70 pF) of LBC loads.
#A selectable dual frequency system clock.
#Low clock edge jitter, due to high VCO stability.
The Clock Generation Module is comprised of 6 main func-
tional blocks:
Reference Selector
Phase Comparator
Loop Filter
250 MHz Voltage Controlled Oscillator
Output Phasing and Divide by 10
See
Figure 3-18
, Clock Generation Module Block Diagram.
REFERENCE SELECTOR
The Reference Selector block allows the user to choose
between 2 sources for the Clock Generation Module’s
12.5 MHz reference clock.
The simplest reference clock source option is to use an
external 12.5 MHz reference signal fed into the REFÐIN
input. This input can come from a crystal oscillator module
or from a Local Byte Clock generated by another PLAYERa
device. Using the appropriate crystal oscillator ensures cor-
rect operating frequency without having to adjust any dis-
crete components.
Using an LBC clock from another PLAYERadevice allows
one PLAYERadevice to create a master clock to which
other PLAYERadevices in a system can be synchronized.
Another reference clock source option is a local 12.5 MHz
crystal circuit. An example crystal circuit with component
values is shown in
Figure 3-19.
This circuit is designed to
operate with a crystal that has a CLof 15 pF. The capacitor
values may need to be slightly adjusted for an individual
application to accomodate differences in parasitic loading.
The REFÐSEL signal selects between the two references.
Component Values
Crystal: 12.50000 MHz
R: 270X5%
CISO: 56 pF (1%)
CIN: 54 pF (1%)
COUT: 54 pF (1%)
TL/F/11708 22
FIGURE 3-19. Crystal Circuit
PHASE COMPARATOR
The Phase Comparator uses two signal inputs: the selected
12.5 MHz reference from the Reference Select Block and a
Local Byte Clock that has been selected for the feedback
input, FBKÐIN. Typically, LBC1 is used as the feedback
clock.
The Phase Comparator generates a pulse of current that is
proportional to the phase difference between the two sig-
nals. The current pulses are used to charge and discharge a
control voltage on the internal Loop Filter. This control volt-
age is used to minimize the phase difference between the
two signals.
LOOP FILTER
The Loop Filter is a simple internal filter made up of one
capacitor in parallel with a serial capacitor and resistor com-
bination. One end of the filter is connected to Ground and
the other node is driven by the Phase Comparator and con-
trols the internal 250 MHz Voltage Controlled Oscillator.
This node can be examined for diagnostic purposes on the
LPFLTR pin when the FLTREN bit of the CGMREG register
is enabled. The LPFLTR pin is provided for diagnostic pur-
poses only and should not be connected in any application.
TL/F/11708 21
FIGURE 3-18. Clock Generation Module Block Diagram
23
3.0 Functional Description (Continued)
The voltage on the Loop Filter is set by the current pulses
generated by the Phase Comparator. The voltage on the
Loop Filter node controls the frequency of the 250 MHz
VCO.
250 MHZ VOLTAGE CONTROLLED OSCILLATOR (VCO)
The internal Voltage Controlled Oscillator is a low gain VCO
whose primary frequency of oscillation centers around
250 MHz. The VCO produces little clock jitter due to its
exceptional stability under all circumstances.
The VCO’s output frequency is proportional to the voltage
on the Loop Filter node.
OUTPUT PHASING
The Output Phasing block is a precision clock division circuit
that produces clock signals of 4 distinct frequencies. Within
the 12.5 MHz frequency, 5 clock signals with selectable 8 ns
or 16 ns phase difference are produced.
The following clock signals are produced:
System Clock (CLK16/CLK32)
Local Symbol Clock (LSC)
Local Byte Clocks 15 (LBCn) (Divide by 10)
System Clock (CLK16/CLK32)
The System Clock is provided as an extra set of clock fre-
quencies that may be used as a clock for non-FDDI chipset
portions of a system or as a higher frequency System Inter-
face clock for the MACSI device. This clock is derived by
dividing the 125 MHz clock by 8 or 4 times.
The frequency is selectable through the CLKSEL bit of the
MODE2 register. The output has built-in glitch suppression
so that changing the CLKSEL bit will not result in glitches
appearing at the output.
Local Symbol Clock (LSC)
The Local Symbol Clock is a 40% HIGH/60% LOW duty
cycle clock provided for use by the MACSI device and any
external logic that needs to be synchronized to the Symbol
timing.
This clock is derived by dividing the 125 MHz clock by 5.
Local Byte Clocks 15 (LBCn)
The Local Byte Clocks are provided for use by the MACSI
device, by any external logic that needs to be synchronized
to the Byte timing, and for use in concentrators to synchro-
nize the timing between multiple PLAYERadevices.
These clocks are derived by dividing the 125 MHz clock by
10. The different phase relationships between the LBCs are
achieved by tapping off of different outputs of a Johnson
counter inside the Output Phasing block.
The phase relationship (separation by 8 ns or 16 ns) of the
LBCs is selected using the PHÐSEL pin.
One of the LBCs must be used as the source of the feed-
back input, FBKÐIN, which requires a 12.5 MHz frequency.
When the PLAYERadevice is using a crystal as a refer-
ence it does not matter which LBC is used as the feedback
input. Typically the least loaded LBC is used. However,
when using an external reference that is supplied by anoth-
er PLAYERadevice, it is important to select the LBC that
keeps your system properly synchronized. Typically, all de-
vices will use LBC1 as the feedback input.
3.6 STATION MANAGEMENT SUPPORT
The Station Management Support Block provides a number
of useful features to simplify the implementation of the Con-
nection Management (CMT) portion of SMT.
These features eliminate the most severe CMT response
time constraints imposed by the PCÐReact and CFÐReact
times. The many integrated counters and timers also elimi-
nate the need for additional external devices.
The following CMT features are supported:
#PCÐReact
#CFÐReact
#Auto Scrubbing (TCF Timer)
#Timer, Idle Detection (TID Timer)
#Noise Event Counter (TNE Timer)
#Link Error Monitor (LEM Counter)
PCÐREACT
PCÐReact is one of the timing restrictions imposed by Con-
nection Management (CMT). It is one of the two most crit-
ical timing restrictions imposed (the other being CFÐRe-
act.)
The ANSI SMT standard states that ‘‘PCÐReact is the max-
imum time for PCM [Physical Connection Management]to
make a state transition to PCÐBreak when QLS, a fault
condition, or PCÐStart signal is present. This maximum
time also places a limit on the time to react to a PCÐStop
signal. This limitation does not apply to any other PCM tran-
sitions.’’ PCÐReact puts a sharp time limit on how long it
takes to transition to the PCÐBreak state and transmit the
correct line state when a PCÐBreak transition is required.
The range for the timer is PCÐReact s3.0 ms and has a
default value equal to 3.0 ms.
The PLAYERadevice contains a Trigger Definition Regis-
ter and a set of CMT Condition Registers that can be used
to satisfy the PCÐReact timing.
The Trigger Definition Register (TDR) controls two func-
tions. First, it allows the selection of the line state(s) on
which to trigger (SILS, MLS, HLS . . . ). For PCÐReact, the
line states used would be the ones that caused a transition
to the PCÐBreak state from the current PCM state.
Second, it allows specification of a line state to be transmit-
ted when the trigger condition is met. For PCÐReact, this is
the line state that needs to be transmitted when a transition
to the PCÐBreak state occurs, which is Quiet Line State
(QLS).
The set of CMT Condition registers controls interrupt gener-
ation when a trigger condition occurs. The CMT Condition
Register set includes a CMT Condition Register (CMTCR), a
CMT Condition Comparison Register (CMTCCR), and a
CMT Condition Mask Register (CMTCMR).
Line state triggering for PCÐReact is enabled by selecting
line states to trigger on from the Trigger Definition Register
(TDR) bits 3-7.
The Trigger Condition Occurred (TCO) bit of the CMTCR is
automatically set when the trigger condition specified by the
TDR register is met.
The line state specified by the Trigger Definition Register
(TDR) bits 02 is then loaded into the Current Transmit
Mode Register (CTSR), causing the line state to be trans-
mitted.
24
3.0 Functional Description (Continued)
If the TCO Mask (TCOM) bit of the CMTCMR is set, then
whenever the CMTCR.TCO bit becomes set the Receive
Condition Register B’s Connection Service Event
(RCRB.CSE) bit will be set. This allows an interrupt to be
generated for the trigger event.
As an example, suppose the PCM state machine is in the
ACTIVE state. From this state, if a Halt Line State (HLS) or
Quiet Line State (QLS) is detected, or the Noise Threshold
is reached, the state machine must move to the PCÐBreak
state and begin transmitting QLS. To implement this behav-
ior when the PCÐACTIVE state is entered, set
TDR.TTM20 to 110 (Quiet Transmit), set TDR.TOHLS,
TDR.TOQLS, and TDR.TONT and reset all other bits (TO-
SILS and TOMLS). Also set CMTCMR.TCOM if an interrupt
is desired.
CFÐREACT
CFÐReact is one of the timing restrictions imposed by Con-
nection Management (CMT). It is one of the two most crit-
ical timing restrictions imposed (the other being
PCÐReact).
The ANSI SMT standard states that ‘‘CFÐReact is the max-
imum time for CFM [Configuration Management]to recon-
figure to remove a non-Active connection from the token
path.’’
The range for the timer is CFÐReact s3.0 ms and has a
default value equal to 3.0 ms.
The PLAYERadevice contains a Trigger Transition Config-
uration Register and a set of CMT Condition Registers that
can be used to satisfy the CFÐReact timing.
he Trigger Transition Configuration Register (TTCR) holds
the new configuration switch settings to be loaded into the
Configuration Register (CR) when a trigger condition occurs.
Enabling line state triggering with the Trigger Definition Reg-
ister (TDR) bits 37 also enables the CFÐReact response.
This means that whenever trigger conditions are actively
used for PCÐReact, the value of the TTCR register will be
used also. This implies that it either must always then be
loaded with the current configuration setting, causing no
change to the CR, or it must be loaded with the appropriate
value to accommodate the CFÐReact function.
The Trigger Transition Configuration Register (TTCR) must
be set the configuration desired when the trigger condition
occurs. When the trigger condition occurs the value of this
register is loaded into the Configuration Register (CR). Dur-
ing this time writes to the CR are inhibited.
To continue the example from the PCÐReact description,
suppose that when in the ACTIVE state for the PCM state
machine, the CFM state machine is also in the THRUÐA
state. If trigger conditions are enabled via the
CMTCMR.TCOM bit and it is desired to not implement CFÐ
React, TTCR must be set to the present value of CR. If it is
desired to not implement CFÐReact then TTCR should be
set to the value which would change the configuration to the
WRAP state. The wrap conditions WRAPÐA or WRAPÐB
depend on which PHY gets reconfigured.
AUTO SCRUBBING
Auto Scrubbing is an additional CMT feature that further
enhances the automatic configuration switch setting in or-
der to meet the CFÐReact timing. When enabled, Auto
Scrubbing causes 2 PHYÐInvalid symbols followed by
Scrub Symbol pairs (Idles) to be sourced for a user select-
able duration (the scrubbing time) after a trigger condition
(the same one used for PCÐReact and CFÐReact) occurs
and prior to a change in the configuration switch setting on
all indicate ports that will be changed.
Auto Scrubbing is enabled by setting the Enable Scrubbing
on Trigger Conditions (ESTC) bit of Mode Register 2
(MODE2).
The Scrub Timer Threshold Register (STTR) defines the du-
ration of the scrubbing, which can last up to approximately
10ms. The Scrub Timer Value Register (STVR) can be used
to examine a snapshot of the upper 8 bits of the STTR
register.
TIMER, IDLE DETECTION
The Idle Detection Timer is required to flag the continued
presence of the Idle Line State for a duration of 8 Idle Sym-
bol pairs plus 1 symbol pair.
This feature is implemented in the Receiver Block by the
Super Idle Line State (SILS).
NOISE EVENT COUNTER
The Noise Event Counter can be used to time the duration
between Noise Events (which are described in detail below)
and to count frame sizes. The first feature is the most often
recognized, but the second is often overlooked and can
lead to potential difficulty if not properly set.
The Noise Event Counter is implemented as a pair of down
counters: one the actual Noise Counter and the other a
Noise Counter Prescaling value. The Noise Threshold Reg-
ister (NTR) and the Noise Prescale Threshold Register
(NPTR) can be programmed to the counter’s initial value
while the Current Noise Count Register (CNCR) and the
Current Noise Prescale Count Register (CNPCR) provide a
snapshot of the actual counter.
The Noise Event Counter decrements whenever a Noise
Line State (NLS), Line State Unknown (LSU), or Active Line
State (ALS) is received and has its start value reloaded
whenever it receives Halt Line State (HLS), Idle Line State
(ILS), Master Line State (MLS), Quiet Line State (QLS), or
No Signal Detect (NSD). The Noise Event Counter is also
reset for a Start or End Delimiter. This means the Noise
counter increments for bad events as well as for every data
symbol in a frame. Should the Noise Counter expire, it indi-
cates that a new line state (including ALS) has not been
entered for NTÐMAX time. This indicates that either a
frame is too long or that noise is being received.
For this reason it is important to choose a value for the
counter that is larger than the longest frame of 4500 bytes.
The ANSI SMT specification recommends a value for
NTÐMAX of 1.3ms for the noise threshold.
A Noise Event is defined as follows:
A noise event is a noisebyte, or a byte of data which is not in
line with the current line state, indicating error or corruption.
25
3.0 Functional Description (Continued)
TABLE 3-5. Noise Event Description
Noise Event e[SD #ECD]a
[SD #CD #PI #E(II aJK aAB)]a
[SD #CD #EPI #(PB eII) #AB]
Where:
#eLogical AND
ae
Logical OR
EeLogical NOT
SD eSignal Detect
CD eClock Detect
PB ePrevious Byte
PLS ePrevious Line State
PI ePHY Invalid eHLS aQLS
aMLS aNLS
ULS #[PLS
e(ALS aILS)]Ó
ILS eIdle Line State
ALS eActive Line State
ULS eUnknown Line State
HLS eHalt Line State
QLS eQuiet Line State
MLS eMaster Line State
NLS eNoise Line State
ULS eUnknown Line State
IeIdle symbol
JeFirst symbol of start delimiter
KeSecond symbol of start
delimiter
ReReset symbol
SeSet symbol
TeEnd Delimiter
AenaRaSaT
BenaRaSaTaI
neany data symbol
LINK ERROR MONITOR
Link Error Monitoring is accomplished in the PLAYERade-
vice through the Link Error Monitor Counter. The initial value
of this down counter is set using the Link Error Threshold
Register (LETR). A snapshot of the counter can be taken
with the Current Link Error Count Register (CLECR).
A Link Error is defined as follows:
TABLE 3-6. Link Error Event Description
Link Error [ALS #(IEIaxV aVx aHEH)]a
[ALS #ESD]a[ILS #E(II aJK)]a
Event e
[ILS #ESD)]a[ULS #(PLSeALS) #
LinkÐErrorÐFlag #ESB #E(HH aHI
aII aJK)]
Set LinkÐErrorÐFlag e[ALS #(HH aNH aRH a
SH aTH)]
Clear LinkÐErrorÐFlag e[ALS #JK]a
[ILS #JK]a[ULS #(PLSeALS #LinkÐ
ErrorÐFlag #ESB #E(HH aHI aII a
JK)]
Where:
EeLogical NOT
ae
Logical OR
#eLogical AND
ILS eIdle Line State
ALS eActive Line State
ULS eUnknown Line State
xeAny symbol
IeIdle symbol
HeHalt symbol
JeFirst symbol of start delimiter
KeSecond symbol of start
delimiter
VeViolation symbol
ReReset symbol
SeSet symbol
TeEnd delimiter symbol
NeData symbol converted to
0000 by the PLAYERadevice
Receiver Block in symbol pairs
that contain a data and a control
symbol
PLS ePrevious Line State
SD eSignal Detect
SB eStuff Byte: Byte inserted by EB
before a JK symbol pair for
recentering or due to off-axis JK
26
3.0 Functional Description (Continued)
3.7 PHY-MAC INTERFACE
NATIONAL BYTE-WIDE CODE
The PLAYERadevice outputs the National byte-wide code
from its PHY Port Indicate Output to the MAC device. Each
National byte-wide code may contain data or control codes
or the line state information of the connection. Table 3-7
lists all the possible outputs.
During Active Line State all data and control symbols are
being repeated to the PHY Port Indicate Output with the
exception of data in data-control mixture bytes. That data
symbol is replaced by zero. If only one symbol in a byte is a
control symbol, the data symbol will be replaced by 0000
and the whole byte will be presented as control code. Note
that the Line State Detector recognizes the incoming data
to be in the Active Line State upon reception of the Starting
Delimiter (JK symbol pair).
During Idle Line State any non Idle symbols will be reflected
as the code IÊuILS. If both symbols received during Idle Line
State are Idle symbols, then the Symbol Decoder generates
IÊkILS as its output. Note the coded Known/Unknown Bit
(b3) and the Last Known Line State (b20). The Receive
State is 4 bits long and it represents either the PHY Invalid
(0011) or the Idle Line State (1011) condition. The Known/
Unknown Bit shows if the symbols received match the line
state information in the last 3 bits.
During any line state other than Idle Line State or Active
Line State, the Symbol Decoder generates the code VÊkLS
if the incoming symbols match the current line state. The
symbol decoder generates VÊuLS if the incoming symbols
do not match the current line state.
TABLE 3-7. National Byte Wide Code
Current Line State Symbol 1 Symbol 2 National Code
Control Bit Data Control Bit Data Control Bit Data
ALS 0 n 0 n 0 n-n
ALS 0 n 1 C 1 N-C
ALS 1 C 0 n 1 C-N
ALS 1 C 1 C 1 C-C
ILS 1I 1I 1I
Ê
-k-LS
ILS 1 I x Not I 1 IÊ-u-LS
ILS x Not I 1 I 1 IÊ-u-LS
ILS x Not I x Not I 1 IÊ-u-LS
Stuff Byte during ILS x x x x 1 IÊ-k-ILS
Not ALS and Not ILS 1 M 1 M 1 VÊ-k-LS
Not ALS and Not ILS 1 M x Not M 1 VÊ-u-LS
Not ALS and Not ILS x Not M 1 M 1 VÊ-u-LS
Not ALS and Not ILS x Not M x Not M 1 VÊ-u-LS
Stuff Byte during Not ALS x x x x 1 VÊ-k-LS, VÊ-u-LS
or LÊ-u-ILS
EB Overflow/Underflow 1 0011 1011
SMTÐPI Connection (LSU) 1 0011 1010
Scrub Symbol Pair 1 1011 1000
Where:
neAny data symbol in À0, 1, 2 . . . FÓ
CeAny control symbol in ÀV, R, S, T, I, HÓ
Ne0000 eCode for data symbol in a data control mixture byte
IeIdle Symbol
MeAny symbol that matches the current line state
IÊe1011 eFirst symbols of the byte in Idle Line State
VÊe0011 ePHY Invalid
LS eLine State
ALS e000
ILS e001
NSD e010
MLS e100
HLS e101
QLS e110
NLS e111
ue1eIndicates symbol received does not match current line state
ke0eIndicate symbol received matches current line state
xeDon’t care
27
3.0 Functional Description (Continued)
National Byte-Wide Code Example
Incoming 5B Code Decoded 4B Code National Byte-Wide Code (w/o parity)
98765 43210 C 3210 C 3210 C 7654 3210
11111 11111 (II) 1 1010 1 1010 (II) 1 1011 0001 (IÊ-k-ILS)*
11111 11111 (II) 1 1010 1 1010 (II) 1 1011 0001 (IÊ-k-ILS)
11111 11111 (II) 1 1010 1 1010 (II) 1 1011 0001 (IÊ-k-ILS)
11000 10001 (JK) 1 1101 1 1102 (JK) 1 1101 1101 (JK Symbols)
–––- –––- (xx) 0 ––– 0 ––– (xx) 0 –– –– (Data Symbols)
–––- –––- (xx) 0 ––– 0 ––– (xx) 0 –– –– (Data Symbols)
–––- –––- (xx) 0 ––– 0 ––– (xx) 0 –– –– (Data Symbols)
(More data Ð)
–––- –––- (xx) 0 –– 0 –– (xx) 0 –– –– (Data Symbols)
–––- –––- (xx) 0 –– 0 –– (xx) 0 –– –– (Data Symbols)
–––- –––- (xx) 0 –– 0 –– (xx) 0 –– –– (Data Symbols)
01101 00111 (TR) 1 0101 1 0110 (TR) 1 0101 0110 (T and R Symbols)
00111 00111 (RR) 1 0110 1 0110 (RR) 1 0110 0110 (Two R Symbols)
11111 11111 (II) 1 1010 1 1010 (II) 1 1010 1010 (Idle Symbols)
11111 11111 (II) 1 1010 1 1010 (II) 1 1010 1010 (Idle Symbols)
11111 11111 (II) 1 1010 1 1010 (II) 1 1011 0001 (IÊ-k-ILS)
11111 11111 (II) 1 1010 1 1010 (II) 1 1011 0001 (IÊ-k-ILS)
11111 11111 (II) 1 1010 1 1010 (II) 1 1011 0001 (IÊ-k-ILS)
00100 00100 (HH) 1 0001 1 0001 (HH) 1 1011 1001 (IÊ-u-ILS)
00100 00100 (HH) 1 0001 1 0001 (HH) 1 1011 1001 (IÊ-u-ILS)
00100 00100 (HH) 1 0001 1 0001 (HH) 1 1011 1001 (IÊ-u-ILS)
00100 00100 (HH) 1 0001 1 0001 (HH) 1 1011 1001 (IÊ-u-ILS)
00100 00100 (HH) 1 0001 1 0001 (HH) 1 1011 1001 (IÊ-u-ILS)
00100 00100 (HH) 1 0001 1 0001 (HH) 1 1011 1001 (IÊ-u-ILS)
00100 00100 (HH) 1 0001 1 0001 (HH) 1 1011 1001 (IÊ-u-ILS)
00100 00100 (HH) 1 0001 1 0001 (HH) 1 0011 0101 (VÊ-k-HLS)
00100 00100 (HH) 1 0001 1 0001 (HH) 1 0011 0101 (VÊ-k-HLS)
00100 00100 (HH) 1 0001 1 0001 (HH) 1 0011 0101 (VÊ-k-HLS)
11111 11111 (II) 1 1010 1 1010 (II) 1 0011 1101 (VÊ-u-HLS)
11111 11111 (II) 1 1010 1 1010 (II) 1 1011 0001 (IÊ-k-ILS)
11111 11111 (II) 1 1010 1 1010 (II) 1 1011 0001 (IÊ-k-ILS)
*Assume the receiver is in the Idle Line State.
28
3.0 Functional Description (Continued)
3.8 PMD INTERFACE
The PMD Interface connects the PLAYERadevice to a
standard FDDI Physical Media Connection such as a fiber
optic transceiver or a copper twisted pair transceiver. It is a
125 MHz full duplex serial connection.
The DP83256 PLAYERadevice contains one PMD inter-
face. This PMD Interface should be used for all PMD imple-
mentations that do not require an external scrambler/
descrambler function, clock recovery function, or clock
generation function, such as a Fiber Optic or Shielded
Twisted Pair (SDDI) PMDs.
The DP83256-AP and DP83257 PLAYERadevices contain
two PMD interfaces. The PMD Interface should be used for
all PMD implementations that do not require an external
scrambler/descrambler function, clock recovery function,
or clock generation function, such as a Fiber Optic or
Shielded Twisted Pair (SDDI) PMDs. The second, Alternate
PMD Interface can be used to support Unshielded Twisted
Pair (UTP) PMDs that require external scrambling, and al-
lows implementation with no external clock recovery or
clock generation functions required. See
Figure 3-21.
PLAYERaTO PMD CONNECTIONS
The following figures illustrate how the PLAYERadevice
can be connected to various types of PMDs.
Figure 3-20
shows how the DP83256, DP83256-AP, or
DP83257 PLAYERadevice is connected to a Fiber Optic
or Shielded Twisted Pair (SDDI) PMD using the Primary
PMD Interface.
Figure 3-21
shows how the DP83256-AP or DP83257
PLAYERadevice is connected to an Unshielded Twisted
Pair (UTP) PMD using the Alternate PMD Interface.
TL/F/11708 47
FIGURE 3-20. Fiber Optic or STP PMD Connection
TL/F/11708 48
FIGURE 3-21. UTP PMD Connections
29
3.0 Functional Description (Continued)
INTERFACE ACTIVATION
The Primary PMD Interface is always enabled.
The Alternate PMD Interface is enabled by programming a
PLAYERaregister bit. To enable the interface, writea1to
the APMDEN bit in the APMDREG register. The interface is
off by default and should be left that way unless it is being
used.
It will also probably be necessary to enable the Transmit
Clocks when using the Alternate PMD Interface. The Trans-
mit Clocks (TXC) are enabled by writing a 1 to the TXCE bit
in the CGMREG register. The transmit clocks are disabled
by default and should be left that way unless it is being
used.
Note that when the Alternate PMD Interface is active, the
Primary PMD Interface can not be used without the Alter-
nate PMD Interface connections. Also note that the Long
Internal Loopback (LILB) can not be used when the Alter-
nate PMD Interface is activated.
30
4.0 Modes of Operation
The PLAYERadevice can operate in 4 basic modes: RUN,
STOP, LOOPBACK, and CASCADE.
4.1 RUN MODE
RUN is the normal mode of operation.
In this mode, the PLAYERadevice is configured to be con-
nected to the media via the PMD transmitter and PMD re-
ceiver at the PMD Interface. It is also connected to any
other PLAYERadevice(s) and/or MACSI device(s) via the
Port A and Port B Interfaces.
While operating in the RUN mode, the PLAYERadevice
receives and transmits Line States (Quiet, Halt, Master, Idle)
and frames (Active LIne State).
4.2 STOP MODE
The PLAYERadevice operates in the STOP mode while it
is being initialized or configured.
The PLAYERadevice is also reset to the STOP mode au-
tomatically when the ERST pin is set to ground.
When in STOP mode, the PLAYERadevice performs the
following functions:
#Resets the Repeat Filter.
#Resets the Smoother.
#Resets the Receiver Block Line State Counters.
#Resets the Clock Recovery Module
#Flushes the Elasticity Buffer.
#Forces Line State Unknown in the Receiver Block.
#Outputs PHY Invalid condition symbol pairs through the
PHY Data Indicate pins (AIP, AIC, AIDk7:0l, BIP, BIC,
BIDk7:0l), when port is enabled.
#Outputs Quiet symbol pairs through the PMD Data Re-
quest pins (PMRDg).
4.3 LOOPBACK MODE
The PLAYERadevice provides 3 types of loopback tests:
Configuration Switch Loopback, Short Internal Loopback,
and Long Internal Loopback. These Loopback modes can
be used to test different portions of the device.
Configuration Switch Loopback
The Configuration Switch Loopback can be used to test the
data paths of the MACSI device(s) that are connected to the
PLAYERadevice before transmitting and receiving data
through the network.
In the Configuration Switch Loopback mode, the PLAYERa
device Configuration Register (CR) can be programmed to
perform the following functions:
#Select Port A PHY Request Data, Port B PHY Request
Data, or PHY Invalid to connect to Port A PHY Indicate
Data via the AÐIND Mux.
#Select Port A PHY Request Data, Port B PHY Request
Data, or PHY Invalid to connect to Port B PHY Indicate
Data via the BÐIND Mux.
#Connect data from the Receiver Block to the Transmitter
Block via the TransmitterÐMux. (The PLAYERadevice
is repeating incoming data from the media in the Configu-
ration Switch Loopback mode.)
See
Figure 4-1
and
Figure 4-2.
TL/F/11708 23
FIGURE 4-1. Configuration Switch Loopback
for DP83257
TL/F/11708 24
FIGURE 4-2. Configuration Switch Loopback
for DP83256 and DP 83256-AP
31
4.0 Modes of Operation (Continued)
Short Internal Loopback
The Short Internal Loopback mode can be used to test the
functionality of the PLAYERadevice, not including the
Clock Recovery function, and to test the data paths be-
tween the PLAYERadevice and MACSI devices before
ring insertion.
When in the Short Internal Loopback mode, the PLAYERa
device performs the following functions:
#Directs the output data of the Transmitter Block to the
input of the Receiver Block through an internal path.
#Ignores the PMD Data Indicate pins (PMIDg),
#Outputs Quiet symbols through the PMD Data Request
pins (PMRDg).
The level of the Quiet symbols transmitted through the
PMRDgpins during loopback is automatically set to the
transmitter off level.
If both Short Internal Loopback and Long Internal Loopback
modes are selected, Long Internal Loopback mode will
have priority over Short Internal Loopback mode. This is the
longest loopback path within the PLAYERadevice.
See
Figure 4-3
, Short Internal Loopback.
TL/F/11708 25
FIGURE 4-3. Short Internal Loopback
32
4.0 Modes of Operation (Continued)
Long Internal Loopback
The Long Internal Loopback mode implements the longest
loopback path that is completely within the PLAYERade-
vice.
The Long Internal Loopback mode can be used to test the
functionality of the PLAYERadevice, including the Clock
Recovery function, and to test the data paths between the
PLAYERadevice and MACSI devices before ring insertion.
When in the Long Internal Loopback mode, the PLAYERa
device performs the following functions:
#Directs the output data of the Transmitter Block to the
input of the Clock Recovery Module through an internal
path.
#Ignores the PMD Data Indicate pins (PMIDg),
#Outputs Quiet symbols through the PMD Data Request
pins (PMRDg).
The level of the Quiet symbols transmitted through the
PMRDgpins during loopback is automatically set to the
transmitter off level.
If both Short Internal Loopback and Long Internal Loopback
modes are selected, Long Internal Loopback mode will
have priority over Short Internal Loopback mode. This is the
longest loopback path within the PLAYERadevice.
Note that the LILB path is disconnected and should not be
used when the Alternate PMD Interface is active.
See
Figure 4-4
, Long Internal Loopback.
TL/F/11708 26
FIGURE 4-4. Long Internal Loopback
33
4.0 Modes of Operation (Continued)
4.4 DEVICE RESET
The revision B PLAYERadevice has five different levels of
device ResetÐPower Up Reset, Hardware Reset, Player
Reset, Reference Select Reset, and Stop Mode. The Re-
sets can be used to return the whole device or a portion of
the device to its default configuration.
Power Up Reset begins automatically when power is first
applied to the PLAYERadevice and reaches a certain volt-
age level. Power Up Reset affects all of the modules in the
PLAYERadevice, specifically the Clock Generation Mod-
ule (CGM), Clock Recovery Module (CRM), and the Player
Module, returning each module to its default configuration.
This reset begins by waiting for the crystal to stabilize, then
the CGM PLL proceeds to lock to the crystal and the rest of
the PLAYERadevice is reset. This reset takes the longest
amount of time at approximately 10 ms from the time the
PLAYERadevice’s power supply reaches 4.4V. Even
though the Power Up Reset is usually effective, due to the
variation in the start-up conditions of a systems power sup-
ply, the Power Up Reset trigger can not be guaranteed to
operate correctly. Therefore, a Hardware Reset should al-
ways be performed on the PLAYERaafter waiting a mini-
mum of 10 ms for the Power Up Reset to complete its reset
attempt.
Hardware Reset occurs at the rising edge of PLAYERa
device’s ERST pin. Hardware Reset affects all of the mod-
ules in the PLAYERadevice, specifically the CGM, CRM
and the Player Module, returning each module to its default
configuration. During Hardware Reset it is not necessary to
force the Clock Generation Module to wait for the crystal to
settle again at this time because it has settled in the time
since the initial reset at power up. This reset takes the sec-
ond longest amount of time at approximately 1 ms from the
rising edge of ERST.
Player Reset is activated by writinga1tothePHYRST bit in
Mode Register 2. Player Reset only affects the Player Mod-
ule. This reset is the shortest and only takes about 3 ms
from the completion of the register write. The device should
not be accessed by the Control Bus during this reset.
Reference Select Reset occurs when the PLAYERade-
vice’s REFÐSEL pin is switched from using the REFÐIN
input to using a crystal with the XTALÐIN and XTALÐOUT
pins. This is the same as a Power Up Reset and is done
because the crystal is going from a dead stop to an active
state when REFÐSEL is switched. This reset, like the Pow-
er Up Reset, takes about 10 ms from the falling edge of
REFÐSEL.
Stop Mode is activated by writinga0totheRUNbitinthe
Mode Register. Stop Mode is a selective reset that resets
the Clock Recovery Module and portions of the Player Mod-
ule.
Changes from Revision A to Revision B:
The previous descriptions describe the reset logic in the
revision B PLAYERadevice. Two changes were made to
the original revision A PLAYERadevice reset logic.
First, the Hardware Reset was shortened by eliminating the
requirement of having to wait for the crystal to settle before
letting the Clock Generation Module try to lock to the crys-
tal. This behavior is correct because the PLAYERadevice
has already waited for the crystal to settle once during the
Power Up Reset. The revision A PLAYERafollows a Power
Up Reset cycle when Hardware Reset is activated.
Second, a full Power Up Reset is now done when the clock
reference is switched to the crystal. This is necessary to
allow the crystal time to start up when it is switched to from
the REFÐIN input. This reset is not performed on the revi-
sion A PLAYERa.
Recommendations:
The following are some recommendations for using the re-
set mechanisms of the PLAYERamost effectively:
1. Always wait a minimum of 10 ms after power-up before
doing anything to the PLAYERadevice. 10 ms is a mini-
mum, it may be desirable to wait longer if the system
power supply or clock reference has not stabilized by this
time.
2. Always use the Hardware Reset to reset the PLAYERa
device after Power Up. This should be done after the
initial Power Up waiting period of at least 10 ms.
34
4.0 Modes of Operation (Continued)
4.5 CASCADE MODE
The PLAYERadevice can operate in the Cascade (paral-
lel) mode
(Figure 4-5)
which is used in high bandwidth,
point-to-point data transfer applications. This is a non-FDDI
mode of operation. This is only available on the DP83257
device.
Concepts
In the Cascade mode, multiple PLAYERadevices are con-
nected together to provide data transfer at multiples of the
FDDI data rate. Two cascaded PLAYERadevices provide
a data rate twice the FDDI data rate; three cascaded
PLAYERadevices provide a data rate three times the FDDI
data rate, etc.
Multiple data streams are transmitted in parallel over each
pair of cascaded PLAYERadevices. All data streams start
simultaneously and begin with the JK symbol pair on each
PLAYERadevice.
Data is synchronized at the receiver of each PLAYERade-
vice by the JK symbol pair. Upon receiving a JK symbol pair,
a PLAYERadevice asserts the Cascade Ready signal to
indicate the beginning of data reception.
The Cascade Ready signals of all PLAYERadevices are
open drain ANDed together to create the Cascade Start
signal. The Cascade Start signal is used as the input to
indicate that all PLAYERadevices have received the JK
symbol pair. Data is now being received at every PLAYERa
device and can be transferred from the cascaded
PLAYERadevices to the host system.
See
Figure 4-6
for more information.
Operating Rules
When the PLAYERadevice is operating in Cascade mode,
the following rules apply:
1. Data integrity can be guaranteed if the worst case PMD
transmission skew between parallel media is less than
40 ns. For example, this amounts to about 785 meters of
fiber optic cable, assuming a 1% worst case variance.
2. Even though this is a non-FDDI application, the general
rules for FDDI frames must be obeyed.
#Data frames must be a minimum of three bytes long
(including the JK symbol pair). Smaller frames will
cause Elasticity Buffer errors.
#Data frames must have a maximum size of 4500 bytes,
with a JK starting delimiter and a T or R or S ending
delimiter.
3. Due to the different clock rates, the JK symbol pair may
arrive at different times at each PLAYERadevice. The
total skew between the fastest and slowest cascaded
PLAYERadevices receiving the JK starting delimiter
must not exceed 80 ns.
4. The first PLAYERadevice to receive a JK symbol pair
will present it to the host system and release the Cas-
cade Ready signal. The PLAYERadevice will present
one more JK as it waits for the other PLAYERadevices
to recognize their JK. The maximum number of consecu-
tive JKs that can be presented to the host is 2.
5. The Cascade Start signal is set to 1 when all the cascad-
ed PLAYERadevices release their Cascade Ready sig-
nals.
6. Bit 4 (CSE) of the Receive Condition Register B (RCRB)
is set to 1 if the Cascade Start signal (CS) is not set
before the second falling edge of clock signal LBC from
when Cascade Ready (CR) was released. CS has to be
set approximately within 80 ns of CR release. This condi-
tion signifies that not all cascaded PLAYERadevices
have received their respective JK symbol pair with the
allowed skew range.
7. PLAYERadevices may not report a Cascaded Synchro-
nization Error if the JK symbols are corrupted in the point-
to-point links.
8. To guarantee integrity of the interframe information, the
user must put at least 8 Idle symbol pairs between
frames. The PLAYERadevice will function properly with
only 4 Idle symbol pairs, however the interframe symbols
may be corrupted with random non-JK symbols.
The MACSI device could be used to provide the required
framing and optional FCS support.
35
4.0 Modes of Operation (Continued)
TL/F/11708 27
FIGURE 4-5. Parallel Transmission
TL/F/11708 28
FIGURE 4-6. Cascade Mode of Operation
36
5.0 Registers
The PLAYERadevice can be initialized, configured, and monitored using 64 8-bit registers. These registers are accessible
through the Control Bus Interface.
The following tables summarize each register’s attributes.
Note: RESERVED Registers may be read at any time, although the values read are not specified. The results of RESERVED Register writes are not specified, and
may have adverse implications. The user should not write to RESERVED Register locations.
TABLE 5-1. Register Summary
Register
Address
Register
Symbol Register Name Access Rules
Read Write
00h MR Mode Register Always Always
01h CR Configuration Register Always Conditional
02h ICR Interrupt Condition Register Always Conditional
03h ICMR Interrupt Condition Mask Register Always Always
04h CTSR Current Transmit State Register Always Conditional
05h IJTR Injection Threshold Register Always Always
06h ISRA Injection Symbol Register A Always Always
07h ISRB Injection Symbol Register B Always Always
08h CRSR Current Receive State Register Always Write Reject
09h RCRA Receive Condition Register A Always Conditional
0Ah RCRB Receive Condition Register B Always Conditional
0Bh RCMRA Receive Condition Mask Register A Always Always
0Ch RCMRB Receive Condition Mask Register B Always Always
0Dh NTR Noise Threshold Register Always Always
0Eh NPTR Noise Prescale Threshold Register Always Always
0Fh CNCR Current Noise Count Register Always Write Reject
10h CNPCR Current Noise Prescale Count Register Always Write Reject
11h STR State Threshold Register Always Always
12h SPTR State Prescale Threshold Register Always Always
13h CSCR Current State Count Register Always Write Reject
14h CSPCR Current State Prescale Count Register Always Write Reject
15h LETR Link Error Threshold Register Always Always
16h CLECR Current Link Error Count Register Always Write Reject
17h UDR User Definable Register Always Always
18h IDR Device ID Register Always Write Reject
19h CIJCR Current Injection Count Register Always Write Reject
1Ah ICCR Interrupt Condition Comparison Register Always Always
1Bh CTSCR Current Transmit State Comparison Register Always Always
1Ch RCCRA Receive Condition Comparison Register A Always Always
37
5.0 Registers (Continued)
TABLE 5-1. Register Summary (Continued)
Register
Address
Register
Symbol Register Name Access Rules
Read Write
1Dh RCCRB Receive Condition Comparison Register B Always Always
1Eh MODE2 Mode Register 2 Always Conditional
1Fh CMTCCR CMT Condition Comparison Register Always Always
20h CMTCR CMT Condition Register Always Conditional
21h CMTMR CMT Condition Mask Register Always Always
22h RR22 Reserved Register 22 Always DO NOT WRITE
23h RR23 Reserved Register 23 Always DO NOT WRITE
24h STTR Scrub Timer Threshold Register Always Always
25h STVR Scrub Timer Value Register Always Write Reject
26h TDR Trigger Definition Register Always Always
27h TTCR Trigger Transition Configuration Register Always Always
28h RR28 Reserved Register 28 Always DO NOT WRITE
29h RR29 Reserved Register 29 Always DO NOT WRITE
2Ah RR2A Reserved Register 2A Always DO NOT WRITE
2Bh RR2B Reserved Register 2B Always DO NOT WRITE
2Ch RR2C Reserved Register 2C Always DO NOT WRITE
2Dh RR2D Reserved Register 2D Always DO NOT WRITE
2Eh RR2E Reserved Register 2E Always DO NOT WRITE
2Fh RR2F Reserved Register 2F Always DO NOT WRITE
30h RR30 Reserved Register 30 Always DO NOT WRITE
31h RR31 Reserved Register 31 Always DO NOT WRITE
32h RR32 Reserved Register 32 Always DO NOT WRITE
33h RR33 Reserved Register 33 Always DO NOT WRITE
34h RR34 Reserved Register 34 Always DO NOT WRITE
35h RR35 Reserved Register 35 Always DO NOT WRITE
36h RR36 Reserved Register 36 Always DO NOT WRITE
37h RR37 Reserved Register 37 Always DO NOT WRITE
38h RR38 Reserved Register 38 Always DO NOT WRITE
39h RR39 Reserved Register 39 Always DO NOT WRITE
3Ah RR3A Reserved Register 3A Always DO NOT WRITE
3Bh CGMREG Clock Generation Module Register Always Always
3Ch APMDREG Alternate PMD Register Always Always
3Dh GAINREG Gain Register Always Always
3Eh RR3E Reserved Register 3E Always DO NOT WRITE
3Fh RR3F Reserved Register 3F Always DO NOT WRITE
38
5.0 Registers (Continued)
TABLE 5-2. Register Bit Summary
Register
Address
Register
Symbol
Bit Symbols
D7 D6 D5 D4 D3 D2 D1 D0
00h MR RNRZ TNRZ TE TQL CM EXLB ILB RUN
01h CR BIE AIE TRS1 TRS0 BIS1 BIS0 AIS1 AIS0
02h ICR UDI RCB RCA LEMT CWI CCR CPE DPE
03h ICMR UDIM RCBM RCAM LEMTM CWIM CCRM CPEM DPEM
04h CTSR RES PRDPE SE IC1 IC0 TM2 TM1 TM0
05h IJTR IJT7 IJT6 IIJ5 IJT4 IJT3 IJT2 IJT1 IJT0
06h ISRA RES RES RES IJS4 IJS3 IJS2 IJS1 IJS0
07h ISRB RES RES RES IJS9 IJS8 IJS7 IJS6 IJS5
08h CRSR RES RES RES RES LSU LS2 LS1 LS0
09h RCRA LSUPI LSC NT NLS MLS HLS QLS NSD
0Ah RCRB RES SILS EBOU CSE LSUPV ALS ST ILS
0Bh RCMRA LSUPIM LSCM NTM NLSM MLSM HLSM QLSM NSDM
0Ch RCMRB RES SILSM EBOUM CSEM LSUPVM ALSM STM ILSM
0Dh NTR RES NT6 NT5 NT4 NT3 NT2 NT1 NT0
0Eh NPTR NPT7 NPT6 NPT5 NPT4 NPT3 NPT2 NPT1 NPT0
0Fh CNCR NCLSCD CNC6 CNC5 CNC4 CNC3 CNC2 CNC1 CNC0
10h CNPCR CNPC7 CNPC6 CNPC5 CNPC4 CNPC3 CNPC2 CNPC1 CNPC0
11h STR RES ST6 ST5 ST4 ST3 ST2 ST1 ST0
12h SPTR SPT7 SPT6 SPT5 SPT4 SPT3 SPT2 SPT1 SPT0
13h CSCR SCLSCD CSC6 CSC5 CSC4 CSC3 CSC2 CSC1 CSC0
14h CSPCR CSPC7 CSPC6 CSPC5 CSPC4 CSPC3 CSPC2 CSPC1 CSPC0
15h LETR LET7 LET6 LET5 LET4 LET3 LET2 LET1 LET0
16h CLECR LEC7 LEC6 LEC5 LEC4 LEC3 LEC2 LEC1 LEC0
17h UDR RES RES RES RES EB1 EB0 SB1 SB0
18h IDR DID7 DID6 DID5 DID4 DID3 DID2 DID1 DID0
19h CIJCR IJC7 IJC6 IJC5 IJC4 IJC3 IJC2 IJC1 IJC0
1Ah ICCR UDIC RCBC RCAC LEMTC CWIC CCRC CPEC DPEC
1Bh CTSCR RESC PRDPEC SEC IC1C IC0C TM2C TM1C TM0C
1Ch RCCRA LSUPIC LSCC NTC NLSC MLSC HLSC QLSC NSDC
1Dh RCCRB RESC SILSC EBOUC CSEC LSUPVC ALSC STC ILSC
1Eh MODE2 ESTC RES CLKSEL RES RES RES CBPE PHYRST
1Fh CMTCCR TCOC STEC RES RES RES RES RES RES
20h CMTCR TCO STE RES RES RES RES RES RES
21h CMTMR TCOM STEM RES RES RES RES RES RES
22h RR22 RES RES RES RES RES RES RES RES
39
5.0 Registers (Continued)
TABLE 5-2. Register Bit Summary (Continued)
Register
Address
Register
Symbol
Bit Symbols
D7 D6 D5 D4 D3 D2 D1 D0
23h RR23 RES RES RES RES RES RES RES RES
24h STTR STT7 STT6 STT5 STT4 STT3 STT2 STT1 STT0
25h STVR STV7 STV6 STV5 STV4 STV3 STV2 STV1 STV0
26h TDR TONT TOQLS TOHLS TOMLS TOSILS TTM2 TTM1 TTM0
27h TTCR BIE AIE TRS1 TRS0 BIS1 BIS0 AIS1 AIS0
28h RR28 RES RES RES RES RES RES RES RES
29h RR29 RES RES RES RES RES RES RES RES
2Ah RR2A RES RES RES RES RES RES RES RES
2Bh RR2B RES RES RES RES RES RES RES RES
2Ch RR2C RES RES RES RES RES RES RES RES
2Dh RR2D RES RES RES RES RES RES RES RES
2Eh RR2E RES RES RES RES RES RES RES RES
2Fh RR2F RES RES RES RES RES RES RES RES
30h RR30 RES RES RES RES RES RES RES RES
31h RR31 RES RES RES RES RES RES RES RES
32h RR32 RES RES RES RES RES RES RES RES
33h RR33 RES RES RES RES RES RES RES RES
34h RR34 RES RES RES RES RES RES RES RES
35h RR35 RES RES RES RES RES RES RES RES
36h RR36 RES RES RES RES RES RES RES RES
37h RR37 RES RES RES RES RES RES RES RES
38h RR38 RES RES RES RES RES RES RES RES
39h RR39 RES RES RES RES RES RES RES RES
3Ah RR3A RES RES RES RES RES RES RES RES
3Bh CGMREG RES RES FLTREN RES TXCE RES RES RES
3Ch APMDREG RES RES RES RES APMDEN RES RES RES
3Dh GAINREG FILT2 FILT1 FILT0 RES RES RES RES RES
3Eh RR3E RES RES RES RES RES RES RES RES
3Fh RR3F RES RES RES RES RES RES RES RES
40
5.0 Registers (Continued)
TABLE 5-3. Register Reset Value Summary
Register
Address
Register
Symbol
Reset Contents
MSB-LSB Comments
00h MR 00 h
01h CR 00 h
02h ICR X001 0000 B depends on sense pins
03h ICMR 00 h
04h CTSR A2 h
05h IJTR 00 h
06h ISRA 00 h
07h ISRB 00 h
08h CRSR 0A h
09h RCRA 20 h
0Ah RCRB 00X0 0010 B depends on EB state
0Bh RCMRA 00 h
0Ch RCMRB 00 h
0Dh NTR 00 h
0Eh NPTR 00 h
0Fh CNCR 00 h
10h CNPCR 00 h
11h STR 00 h
12h SPTR 00 h
13h CSCR 00 h
14h CSPCR 00 h
15h LETR 00 h
16h CLECR 00 h
17h UDR 000X 00XX B depends on sense pins
18h IDR XX h depends on chip version
19h CIJCR 00 h
1Ah ICCR 00 h same as reg 02 h if reg 02 h is read first
1Bh CTSCR 00 h same as reg 04 h if reg 04 h is read first
1Ch RCCRA 00 h same as reg 09 h if reg 09 h is read first
1Dh RCCRB 00 h same as reg 0A h if reg 0A h is read first
41
5.0 Registers (Continued)
TABLE 5-3. Register Reset Value Summary (Continued)
Register
Address
Register
Symbol
Reset Contents
MSB-LSB Comments
1Eh MODE2 00 h
1Fh CMTCCR 00 h
20h CMTCR 00 h
21h CMTMR 00 h
22h RR22 XX h
23h RR23 XX h
24h STTR 00 h
25h STVR 00 h
26h TDR 00 h
27h TTCR 00 h
28h RR28 XX h
29h RR29 XX h
2Ah RR2A XX h
2Bh RR2B XX h
2Ch RR2C XX h
2Dh RR2D XX h
2Eh RR2E XX h
2Fh RR2F XX h
30h RR30 XX h
31h RR31 XX h
32h RR32 XX h
33h RR33 XX h
34h RR34 XX h
35h RR35 XX h
36h RR36 XX h
37h RR37 XX h
38h RR38 XX h
39h RR39 XX h
3Ah RR3A XX h
3Bh CGMREG 05 h
3Ch APMDREG 00 h
3Dh GAINREG 00 h
3Eh RR3E XX h
3Fh RR3F XX h
42
5.0 Registers (Continued)
5.1 MODE REGISTER (MR)
The Mode Register is used to initialize and configure the PLAYERadevice.
ACCESS RULES
ADDRESS READ WRITE
00h Always Always
D7 D6 D5 D4 D3 D2 D1 D0
RNRZ TNRZ TE TQL CM LILB SILB RUN
Bit Symbol Description
D0 RUN RUN/ESTOP:
0: Enables the STOP mode. Refer to section 4.2, STOP MODE, for more information.
1: Normal operation (i.e. RUN mode).
Note: The RUN bit is automatically set to 0 when the ERST pin is asserted (i.e. set to ground).
D1 SILB SHORT INTERNAL LOOPBACK:
0: Disables Internal Loopback mode (i.e. normal operation).
1: Enables Internal Loopback mode.
Refer to section 4.3, LOOPBACK MODE, for more information.
D2 LILB LONG INTERNAL LOOPBACK:
0: Disables Long Internal Loopback mode (i.e. normal operation).
1: Enables Long Internal Loopback mode.
Note: Long Internal Loopback should not be used when the Alternate PMD Interface is enabled.
Refer to section 4.3, LOOPBACK MODE, for more information.
D3 CM CASCADE MODE:
0: Disables synchronization of cascaded PLAYERadevices.
1: Enables the synchronization of cascaded PLAYERadevices.
Refer to section 4.4, CASCADE MODE, for more information.
Note: Cascade Mode is only available on the DP83257 device. The other devices do not have the required CS and CR pins. Do not set this bit for
any device but the DP83257.
D4 TQL TRANSMIT QUIET LEVEL: This bit is used to program the transmission level of the Quiet symbols during Off
Transmit mode (OTM) only.
0: Low (PMD OFF) level Quiet symbols are transmitted through the PMD Data Request pins (i.e. PMRD aelow,
PMRD behigh).
1: High (PMD ON) level Quiet symbols are transmitted through the PMD Data Request pins (i.e. PMRD aehigh,
PMRD below).
D5 TE TRANSMIT ENABLE: The TE bit controls the action of the PMD transmitter Enable (TXE) pin. When TE is 0, the
TXE output disables the PMD transmitter; when TE is 1, the PMD transmitter is disabled during the Off Transmit
Mode (OTM) and enabled otherwise. The On and Off level of the TXE is depended on the PMD transmitter Enable
Level (TEL) pin to the PLAYERadevice. The following rules summaries the output of TXE.
1. If TEe0, then TXEeOff
2. If TEe1 and OTM, then TXEeOff
3. If TEe1 and not OTM, then TXEeOn.
D6 TNRZ TRANSMIT NRZ DATA:
0: Transmits data in Non-Return-To-Zero-Invert-On-Ones (NRZI) format (normal format).
1: Transmits data in Non-Return-To-Zero format (NRZ).
D7 RNRZ RECEIVE NRZ DATA:
0: Receives data in Non-Return-To-Zero-Invert-On-Ones format (NRZI) (normal format).
1: Receives data in Non-Return-To-Zero format (NRZ).
43
5.0 Registers (Continued)
5.2 CONFIGURATION REGISTER (CR)
The Configuration Register controls the Configuration Switch Block and enables/disables both the A and B ports. The CR can
be used to create a number of Configuration Loopback paths.
The CR is conditionally writable because the TTCR can be writing a new value into the register if this feature is enabled.
Note that the AÐRequest and BÐIndicate port are offered only on the DP83257, and not in the DP83256. For further informa-
tion, refer to section 3.4, CONFIGURATION SWITCH.
ACCESS RULES
ADDRESS READ WRITE
01h Always Conditional
D7 D6 D5 D4 D3 D2 D1 D0
BIE AIE TRS1 TRS0 BIS1 BIS0 AIS1 AIS0
Bit Symbol Description
D0, D1 AIS0, AIS1 AÐINDICATE SELECTOR k0, 1l:The AÐIndicate Selector k0, 1lbits selects one of the four
Configuration Switch data buses for the AÐIndicate output port (AIP, AIC, AIDk7:0l).
AIS1 AIS0
0 0 PHY Invalid Bus
0 1 Receiver Bus
10A
Ð
Request Bus
11B
Ð
Request Bus
D2, D3 BIS0, BIS1 BÐINDICATE SELECTOR k0, 1l:The BÐIndicate Selector k0, 1lbits selects one of the four
Configuration Switch data buses for the BÐIndicate output port (BIP, BIC, BIDk7:0l)
BIS1 BIS0
0 0 PHY Invalid Bus
0 1 Receiver Bus
10A
Ð
Request Bus
11B
Ð
Request Bus
Note: Even though this bit can be set and/or cleared in the DP83256, it will not affect any I/Os since the DP83256 does not offer a
BÐIndicate port.
D4, D5 TRS0, TRS1 TRANSMIT REQUEST SELECTOR k0, 1l:The Transmit Request Selector k0, 1lbits select one of
the four Configuration Switch data buses for the input to the Transmitter Block.
TRS1 TRS0
0 0 PHY Invalid Bus
0 1 Receiver Bus
10A
Ð
Request Bus
11B
Ð
Request Bus
Note: If the PLAYERadevice is in Active Transmit Mode (i.e. the Transmit Mode bits (TMk2:0l) of the Current Transmit State
Register (CTSR) are set to 00) and the PHY Invalid Bus is selected, then the PLAYERadevice will transmit a maximum of four
Halt symbol pairs and then continuous Idle symbols due to the Repeat Filter when in the Repeat state.
D6 AIE AÐINDICATE ENABLE:
0: Disables the AÐIndicate output port. The AÐIndicate port pins will be tri-stated when the port is
disabled.
1: Enables the AÐIndicate output port (AIP, AIC, AIDk7:0l).
D7 BIE BÐINDICATE ENABLE:
0: Disables the BÐIndicate output port. The BÐIndicate port pins will be tri-stated when the port is
disabled.
1: Enables the BÐIndicate output port (BIP, BIC, BIDk7:0l).
Note: Even though this bit can be set and/or cleared in the DP83256, it will not affect any I/Os since the DP83256 does not offer a
BÐIndicate port.
44
5.0 Registers (Continued)
5.3 INTERRUPT CONDITION REGISTER (ICR)
The Interrupt Condition Register records the occurrence of an internal error event, the detection of Line State, an unsuccessful
write by the Control Bus Interface, the expiration of an internal counter, or the assertion of one or more of the User Definable
Sense pins.
The Interrupt Condition Register will assert the Interrupt pin (EINT) when one or more bits within the register are set to 1 and
the corresponding mask bits in the Interrupt Condition Mask Register (ICMR) are also set to 1.
ACCESS RULES
ADDRESS READ WRITE
02h Always Conditional
D7 D6 D5 D4 D3 D2 D1 D0
UDI RCB RCA LEMT CWI CCR CPE DPE
Bit Symbol Description
D0 DPE PHYÐREQUESTÐDATA PARITY ERROR: This bit will be set to 1 when:
1. The PHY Request Data Parity Enable bit (PRDPE) of the Current Transmit State Register (CTSR) is set to 1 and
2. The Transmitter Block detects a parity error in the incoming PHY Request Data.
The source of the data can be from the PHY Invalid Bus, the Receive Bus, the AÐBus, or the BÐBus of the
Configuration Switch.
Note: Parity is only checked on data that goes into the transmitter block. This means that any data that is just routed through the configuration
switch without going into the transmit block is not checked.
D1 CPE Control Bus DATA PARITY ERROR: This bit will be set to 1 when the Control Bus Interface detects a parity error
in the incoming Control Bus Data (CBDk7:0l), CBP during a write cycle.
D2 CCR Control Bus WRITE COMMAND REJECT: This bit will be set to 1 when an attempt to write into one of the
following read-only registers is made:
Current Receive State Register (Register 08, CRSR)
Current Noise Count Register (Register 0F, CNCR)
Current Noise Prescale Count Register (Register 10, CNPCR)
Current State Count Register (Register 13, CSCR)
Current State Prescale Count Register (Register 14, CSPCR)
Current Link Error Count Register (Register 16, CLECR)
Device ID Register (Register 18, IDR)
Current Injection Count Register (Register 19, CIJCR)
Scrub Timer Value Register (Register 25, STVR)
45
5.0 Registers (Continued)
Bit Symbol Description
D3 CWI CONDITIONAL WRITE INHIBIT: Set to 1 when bits within mentioned registers do not match bits in the
corresponding compare register. This bit ensures that new (i.e. unread) data is not inadvertently cleared while old
data is being cleared through the Control Bus Interface.
This bit is set to 1 to indicate that a bit in a condition write register was not written because it had changed since
the previous read. The following registers are affected:
Interrupt Condition Register (Register 02, ICR)
Current Transmit State Register (Register 04, CTSR)
Receive Condition Register A (Register 09, RCRA)
Receive Condition Register B (Register 0A, RCRB)
CMT Condition Register (Register 20, CMTCR)
The previous registers are affected when they differ from the value of the corresponding bit in the following
registers respectively:
Interrupt Condition Compare Register (Register 1A, ICCR)
Current Transmit State Compare Register (Register 1B, CTSCR)
Receive Condition Compare Register A (Register 1C, RCCRA)
Receive Condition Compare Register B (Register 1D, RCCRB)
CMT Condition Compare Register (Register 1F, CMTCCR)
This bit must be cleared by software. Note that this differs from the MACSI, BMAC and BSI device bits of the same
name.
The Configuration Register (Register 01, CR) can not be written to during scrubbing.
D4 LEMT LINK ERROR MONITOR THRESHOLD: This bit is set to 1 when the internal 8-bit Link Error Monitor Counter
reaches zero. It will remain set and is cleared by software.
During the reset process (i.e. ERSTeGND), the Link Error Monitor Threshold bit is set to 1 because the Link
Error Monitor Counter is initialized to zero.
D5 RCA RECEIVE CONDITION A: This bit is set to 1 when:
1. One or more bits in the Receive Condition Register A (RCRA) is set to 1 and
2. The corresponding mask bits in the Receive Condition Mask Register A (RCMRA) are also set to 1.
In order to clear (i.e. set to 0) the Receive Condition A bit, the bits within the Receive Condition Register A that are
set to 1 must first be either cleared or masked.
D6 RCB RECEIVE CONDITION B: This bit is set to 1 when:
1. One or more bits in the Receive Condition Register B (RCRB) is set to 1 and
2. The corresponding mask bits in the Receive Condition Mask Register A (RCMRB) are also set to 1.
In order to clear (i.e. set to 0) the Receive Condition B bit, the bits within the Receive Condition Register B that are
set to 1 must first be either cleared or masked.
D7 UDI USER DEFINABLE INTERRUPT: This bit is set to 1 when one or any combination of the Sense Bits (SB0, SB1, or
SB2) in the User Definable Register (UDR) are set to 1.
In order to clear (i.e. set to 0) the User Definable Interrupt Bit, all Sense Bits must be set to 0.
46
5.0 Registers (Continued)
5.4 INTERRUPT CONDITION MASK REGISTER (ICMR)
The Interrupt Condition Mask Register allows the user to dynamically select which events will generate an interrupt.
The Interrupt pin will be asserted (i.e. EINT eGND) when one or more bits within the Interrupt Condition Register (ICR) are set
to 1 and the corresponding mask bits in this register are also set to 1.
This register is cleared (i.e. set to 0) and all interrupts are initially masked during the reset process.
ACCESS RULES
ADDRESS READ WRITE
03h Always Always
D7 D6 D5 D4 D3 D2 D1 D0
UDIM RCBM RCAM LEMTM CWIM CCRM CPEM DPEM
Bit Symbol Description
D0 DPEM PHYÐREQUESTÐDATA PARITY ERROR MASK: The mask bit for the PHYÐRequest Data Parity Error bit
(DPE) of the Interrupt Condition Register (ICR).
D1 CPEM Control Bus DATA PARITY ERROR MASK: The mask bit for the Control Bus Data Parity Error bit (CPE) of the
Interrupt Condition Register (ICR).
D2 CCRM Control Bus WRITE COMMAND REJECT MASK: The mask bit for the Control Bus Write Command Reject bit
(CCR) of the Interrupt Condition Register (ICR).
D3 CWIM CONDITIONAL WRITE INHIBIT MASK: The mask bit for the Conditional Write Inhibit bit (CWI) of the Interrupt
Condition Register (ICR).
D4 LEMTM LINK ERROR MONITOR THRESHOLD MASK: The mask bit for the Link Error Monitor Threshold bit (LEMT) of
the Interrupt Condition Register (ICR).
D5 RCAM RECEIVE CONDITION A MASK: The mask bit for the Receive Condition A bit (RCA) of the Interrupt Condition
Register (ICR).
D6 RCBM RECEIVE CONDITION B MASK: The mask bit for the Receive Condition B bit (RCB) of the Interrupt Condition
Register (ICR).
D7 UDIM USER DEFINABLE INTERRUPT MASK: The mask bit for the User Definable Interrupt bit (UDI) of the Interrupt
Condition Register (ICR).
47
5.0 Registers (Continued)
5.5 CURRENT TRANSMIT STATE REGISTER (CTSR)
The Current Transmit State Register can program the Transmitter Block to internally generate and transmit Idle, Master, Halt,
Quiet, or user programmable symbol pairs, in addition to the normal transmission of incoming PHY Request data. The Smoother
and PHY Request Data Parity are also enabled and disabled through this register.
When the Trigger Definition register (TDR) is used, the CTSR can automatically be set to a preprogrammed line state when a
trigger condition occurs. This capability can be used to implement both PCÐReact and CFÐReact.
The Transmit Modes have priority over the Repeat Filter and Smoother outputs. The Injection Symbols have priority over the
Transmit Modes.
During the reset process (i.e. ERSTeGND) the Transmit Mode is set to Off (TMk2:0le010), the Smoother is enabled (i.e. SE
is set to 1), and the Reserved bit (b7) is set to 1. All other bits of this register are cleared (i.e. set to 0) during the reset process.
When the TDR register is used to respond to trigger conditions the CTSR will be blocked when the TDR register transmit mode
is copied into the CTSR. The Write Reject bit of the ICR will be set if any writes are attempted at this time.
Note: This register has no effect while the device is in Stop Mode.
ACCESS RULES
ADDRESS READ WRITE
04h Always Conditional
D7 D6 D5 D4 D3 D2 D1 D0
RES PRDPE SE IC1 IC0 TM2 TM1 TM0
Bit Symbol Description
D0, D1, TM0, TM1, Transmit Mode k0, 1, 2l:These bits select one of the 6 transmission modes for the PMD Request Data
output port (TXDg).
D2 TM2
TM2 TM1 TM0
000Active Transmit Mode (ATM): Normal transmission of incoming PHY Request data.
001Idle Transmit Mode (ITM): Transmission of Idle symbol pairs (11111 11111).
010Off Transmit Mode (OTM): Transmission of Quiet symbol pairs (00000 00000) and
deassertion of the PMD transmitter Enable pin (TXE).
Note: This is the default transmit mode after reset.
011Reserved: Reserved for future use. Users are discouraged from using this transmit
mode. If selected, however, the transmitter will generate Quiet symbol pairs (00000
00000).
100Master Transmit Mode (MTM): Transmission of Halt and Quiet symbol pairs (00100
00000).
101Halt Transmit Mode (HTM): Transmission of Halt symbol pairs (00100 00100).
110Quiet Transmit Mode (QTM): Transmission of Quiet symbol pairs (00000 00000).
111Reserved: Reserved for future use. Users are discouraged from using this transmit
mode. If selected, however, the transmitter will generate Quiet symbol pairs
(00000 00000).
48
5.0 Registers (Continued)
Bit Symbol Description
D3, D4 IC0, IC1 Injection Control k0, 1l:These bits select one of the 4 injection modes. The injection modes have priority
over data from the Smoother, Repeat Filter, Encoder, and Transmit Modes.
IC0 is the only bit of the register that is automatically cleared by the PLAYERadevice after the One Shot
Injection is executed. The automatic clear of IC0 during the One Shot mode can be interpreted as a
acknowledgment that the One Shot has been completed.
IC1 IC0
00No Injection: The normal transmission of incoming PHY Request data (i.e. symbols are not
injected).
01One Shot: In one shot mode, the contents of Injection Symbol Register A (ISRA) and Injection
Symbol Register B (ISRB) are injected n symbol pairs after a JK, where n is the programmed
value of the Injection Count Register (IJCR). If IJCR is set to 0, the JK symbol pair is replaced by
ISRA and ISRB. Once the One Shot is executed, the PLAYERadevice automatically sets IC0 to
0, thereby returning to normal transmission of data.
10Periodic: In Periodic mode, the contents of Injection Symbol Register A (ISRA) and Injection
Symbol Register B (ISRB) are injected every n-th symbol pair, where n is the programmed value
of the Injection Count Register (IJCR). If IJCR is set to 0, all data symbols are replaced with ISRA
and ISRB.
Note: The inserted symbol is not automatically aligned to a JK boundary.
11Continuous: In Continuous mode, all data symbols are replaced with the contents of Injection
Symbol Register A (ISRA) and Injection Symbol Register B (ISRB).
D5 SE SMOOTHER ENABLE:
0: Disables the Smoother.
1: Enables the Smoother.
When enabled, the Smoother can redistribute Idle symbol pairs which were added or deleted by the
local or upstream receivers.
Note: Once the counter has started, it will continue to count irrespective of the incoming symbols with the exception of a JK symbol pair.
D6 PRDPE PHYÐREQUEST DATA PARITY ENABLE:
0: Disables PHYÐRequest Data parity.
1: Enables PHYÐRequest Data parity.
D7 RES RESERVED: Reserved for future use.
Note: Users are discouraged from using this bit. The reserved bit is set to 1 during the reset process. It may be set or cleared without any
effects to the functionality of the PLAYERadevice.
49
5.0 Registers (Continued)
5.6 INJECTION THRESHOLD REGISTER (IJTR)
The Injection Threshold Register, in conjunction with the Injection Control bits (ICk1:0l) in the Current Transmit State Register
(CTSR), set the frequency at which the contents of the Injection Symbol Register A (ISRA) and Injection Symbol Register B
(ISRB) are inserted into the data stream. It contains the start value for the Injection Counter.
The Injection Threshold Register value is loaded into the Injection Counter when the counter reaches zero or during every
Control Bus Interface write-cycle of this register.
The Injection Counter is an 8-bit down-counter which decrements every 80 ns. It’s current value is read for CIJCR.
The counter is active only during One Shot or Periodic Injection Modes (i.e. Injection Controlk1:0lbits (ICk1:0l)ofthe
Current Transmit State Register (CTSR) are set to either 01 or 10). The Transmitter Block will replace a data symbol pair with
ISRA and ISRB when the counter reaches 0 and the Injection Mode is either One Shot or Periodic.
If the Injection Threshold Register is set to 0 during the One Shot mode, the JK will be replaced with ISRA and ISRB. If the
Injection Threshold Register is set to 0 during the Periodic mode, all data symbols are replaced with ISRA and ISRB.
The counter is initialized to 0 during the reset process (i.e. ERSTeGND).
For further information, see the INJECTION CONTROL LOGIC section.
ACCESS RULES
ADDRESS READ WRITE
05h Always Always
D7 D6 D5 D4 D3 D2 D1 D0
IJT7 IJT6 IJT5 IJT4 IJT3 IJT2 IJT1 IJT0
Bit Symbol Description
D0-D7 IJT0IJT7 INJECTION THRESHOLD BITk0-7l:Start value for the Injection Counter.
IJT0 is the Least Significant Bit (LSB).
50
5.0 Registers (Continued)
5.7 INJECTION SYMBOL REGISTER A (ISRA)
The Injection Symbol Register A, along with Injection Symbol Register B, contains the programmable value (already in 5B code)
that can be inserted to replace the data symbol pairs.
In One Shot mode, ISRA and ISRB are injected n bytes after a JK, where n is the programmed value of the Injection Threshold
Register. In the Periodic mode, ISRA and ISRB are injected every n-th symbol pair. In the Continuous mode, all data symbols are
replaced with ISRA and ISRB.
ACCESS RULES
ADDRESS READ WRITE
06h Always Always
D7 D6 D5 D4 D3 D2 D1 D0
RES RES RES IJS4 IJS3 IJS2 IJS1 IJS0
Bit Symbol Description
D0D4 IJS0IJS4 INJECTION SYMBOL BITk0-4l:Symbol to be injected.
IJS0 is the Least Significant Bit (LSB) and goes out onto the media last.
D5D7 RES RESERVED: Reserved for future use.
Note: Users are discouraged from using these bits. The reserved bits are set to 0 during the reset process. They may be set or cleared
without any effects to the functionality of the PLAYERadevice.
51
5.0 Registers (Continued)
5.8 INJECTION SYMBOL REGISTER B (ISRB)
The Injection Symbol Register B, along with Injection Symbol Register A, contains the programmable value (already in 5B code)
that will replace the data symbol pairs.
In One Shot mode, ISRA and ISRB are injected n bytes after a JK, where n is the programmed value of the Injection Threshold
Register. In the Periodic mode, ISRA and ISRB are injected every n-th symbol pair. In the Continuous mode, all data symbols are
replaced with ISRA and ISRB.
ACCESS RULES
ADDRESS READ WRITE
07h Always Always
D7 D6 D5 D4 D3 D2 D1 D0
RES RES RES IJS9 IJS8 IJS7 IJS6 IJS5
Bit Symbol Description
D0D4 IJS0IJS4 INJECTION SYMBOL BITk0-4l:Symbol to be injected.
IJS0 is the Least Significant Bit (LSB) and goes out onto the media last.
D5D7 RES RESERVED: Reserved for future use.
Note: Users are discouraged from using these bits. The reserved bits are set to 0 during the reset process. They may be set or cleared
without any effects to the functionality of the PLAYERadevice.
52
5.0 Registers (Continued)
5.9 CURRENT RECEIVE STATE REGISTER (CRSR)
The Current Receive State Register represents the current line state being detected by the Receiver Block. When the Receiver
Block recognizes a new Line State, the bits corresponding to the previous line state are cleared, and the bits corresponding to
the new line state are set.
During the reset process (ERSTeGND), the Receiver Block is forced to Line State Unknown (i.e. the Line State Unknown bit
(LSU) is set to 1).
Note: Users are discouraged from writing to this register. An attempt to write into this register will cause the PLAYERadevice to ignore the Control Bus write cycle
and set the Control Bus Write Command Reject bit (CCR) of the Interrupt Condition Register (ICR) to 1.
ACCESS RULES
ADDRESS READ WRITE
08h Always Write Reject
D7 D6 D5 D4 D3 D2 D1 D0
RES RES RES RES LSU LS2 LS1 LS0
Bit Symbol Description
D0, LS0, LS1, LINE STATEk0, 1, 2l:These bits represent the current Line State being detected by the Receiver Block.
Once the Receiver Block recognizes a new line state, the bits corresponding to the previous line state are
D1, D2 LS2
cleared, and the bits corresponding to the new line state are set.
LS2 LS1 LS0
000Active Line State (ALS): Received a JK symbol pair (11000 10001), possibly followed
by data symbols.
001Idle Line State (ILS): Received a minimum of two consecutive Idle symbol pairs
(11111 11111).
010No Signal Detect (NSD): The Signal Detect (SD) has been deasserted, indicating that
the PLAYERadevice is not receiving data from the PMD receiver or that clock detect is
not being received from the Clock Recovery Module. SD is ignored during internal
loopback.
Note: NSD is the default value when the device is in Stop mode. However, while in Stop mode certain data
patterns entering the Receiver Block may cause the PLAYERato set LS0. Therefore, the user may see
either the NSD (010) or Reserved Value (011) during Stop mode.
011Reserved: Reserved for future use.
100Master Line State (MLS): Received a minimum of 8 consecutive Halt-Quiet symbol
pairs (00100 00000).
101Halt Line State (HLS): Received a minimum of 8 consecutive Halt symbol pairs
(00100 00100).
110Quiet Line State (QLS): Received a minimum of 8 consecutive Quiet symbol pairs
(00000 00000).
111Noise Line State (NLS): Detected a minimum of 16 noise events. Refer to the Receiver
Block description for further information on noise events.
D3 LSU LINE STATE UNKNOWN: The Receiver Block has not detected the minimum conditions to enter a known
line state. When the Line State Unknown bit is set, LSk2:0lrepresent the most recently known line state.
D4-D7 RES RESERVED: Reserved for future use.
Note: Users are discouraged from using these bits. The reserved bits are reset to 0 during the reset process. They may be set or cleared
without any effects to the functionality of the PLAYERadevice.
53
5.0 Registers (Continued)
5.10 RECEIVE CONDITION REGISTER A (RCRA)
The Receive Condition Register A maintains a historical record of the Line States recognized by the Receiver Block.
When a new Line State is entered, the bit corresponding to that line state is set to 1. The bits corresponding to the previous Line
States are not cleared by the PLAYERadevice, thereby maintaining a record of the Line States detected.
The Receive Condition A bit (RCA) of the Interrupt Condition Register (ICR) will be set to 1 when one or more bits within the
Receive Condition Register A is set to 1 and the corresponding mask bit(s) in Receive Condition Mask Register A (RCMRA) is
also set to 1.
ACCESS RULES
ADDRESS READ WRITE
09h Always Conditional
D7 D6 D5 D4 D3 D2 D1 D0
LSUPI LSC NT NLS MLS HLS QLS NSD
Bit Symbol Description
D0 NSD NO SIGNAL DETECT: Indicates that the Signal Detect pin (TTLSD) has been deasserted and that the Clock
Recovery Module is not receiving data from the PMD receiver.
D1 QLS QUIET LINE STATE: Received a minimum of eight consecutive Quiet symbol pairs (00000 00000).
D2 HLS HALT LINE STATE: Received a minimum of eight consecutive Halt symbol pairs (00100 00100).
D3 MLS MASTER LINE STATE: Received a minimum of eight consecutive Halt-Quiet symbol pairs (00100 00000).
D4 NLS NOISE LINE STATE: Detected a minimum of sixteen noise events.
D5 NT NOISE THRESHOLD: This bit is set to 1 when the internal Noise Counter reaches 0. It will remain set until a value
equal to or greater than one is loaded into the Noise Threshold Register or Noise Prescale Threshold Register.
During the reset process (i.e. ERSTeGND), since the Noise Counter is initialized to 0, the Noise Threshold bit will
be set to 1.
D6 LSC LINE STATE CHANGE: A line state change has been detected.
D7 LSUPI LINE STATE UNKNOWN AND PHY INVALID: The Receiver Block has not detected the minimum conditions to
enter a known line state.
In addition, the most recently known line state was one of the following line states: No Signal Detect, Quiet Line
State, Halt Line State, Master Line State, or Noise Line State.
54
5.0 Registers (Continued)
5.11 RECEIVE CONDITION REGISTER B (RCRB)
The Receive Condition Register B maintains a historical record of the Lines States recognized by the Receiver Block.
When a new Line State is entered, the bit corresponding to that line state is set to 1. The bits corresponding to the previous Line
States are not cleared, thereby maintaining a record of the Line States detected.
The Receive Condition B bit (RCB) of the Interrupt Condition Register (ICR) will be set to 1 when one or more bits within the
Receive Condition Register B is set to 1 and the corresponding mask bit(s) in Receive Condition Mask Register B (RCMRB) is
also set to 1.
ACCESS RULES
ADDRESS READ WRITE
0Ah Always Conditional
D7 D6 D5 D4 D3 D2 D1 D0
RES SILS EBOU CSE LSUPV ALS ST ILS
Bit Symbol Description
D0 ILS IDLE LINE STATE: Received a minimum of two consecutive Idle symbol pairs (11111 11111).
D1 ST STATE THRESHOLD: This bit will be set to 1 when the internal State Counter reaches zero. It will remain set until
a value equal to or greater than one is loaded into the State Threshold Register or State Prescale Threshold
Register, and this register is cleared.
During the reset process (i.e. ERSTeGND), since the State Counter is initialized to 0, the State Threshold bit is
set to 1.
D2 ALS ACTIVE LINE STATE: Received a JK symbol pair (11000 10001), and possibly data symbols following.
D3 LSUPV LINE STATE UNKNOWN AND PHY VALID: The Receiver Block has not detected the minimum conditions to
enter a known line state.
In addition, the most recently known line state was either Active Line State or Idle Line State.
D4 CSE CONNECTION SERVICE EVENT/CASCADE SYNCHRONIZATION ERROR:
When one or more bits in the CMT Condition Register (CMTCR) are set and the corresponding bit(s) in the CMT
Condition Mask Register (CMTCMR) are set, the Connection service event bit will be set to a 1.
When a synchronization error occurs, the Cascade Synchronization Error bit is set to 1. A synchronization error
occurs if the Cascade Start signal (CS) is not asserted within approximately 80 ns of Cascade Ready (CR) release.
Note: Cascade mode and the CMT features can not be used at the same time.
Note: Cascade mode is only supported on the DP83257 device.
D5 EBOU ELASTICITY BUFFER UNDERFLOW / OVERFLOW: The Elasticity Buffer has either overflowed or underflowed.
The Elasticity Buffer will automatically recover if the condition which caused the error is only transient, but the
event bit will remain set until cleared by software.
D6 SILS SUPER IDLE LINE STATE: Received a minimum of eight Idle symbol pairs (11111 11111).
D7 RES RESERVED: Reserved for future use.
Note: Users are discouraged from using these bits. The reserved bits are reset to 0 during the reset process. They may be set or cleared without
any effects to the functionality of the PLAYERadevice
55
5.0 Registers (Continued)
5.12 RECEIVE CONDITION MASK REGISTER A (RCMRA)
The Receive Condition Mask Register A allows the user to dynamically select which events will generate an interrupt.
The Receive Condition A bit (RCA) of the Interrupt Condition Register (ICR) will be set to 1 when one or more bits within the
Receive Condition Register A (RCRA) is set to 1 and the corresponding mask bit(s) in this register is also set to 1.
Since this register is cleared (i.e. set to 0) during the reset process, all interrupts are initially masked.
ACCESS RULES
ADDRESS READ WRITE
0Bh Always Always
D7 D6 D5 D4 D3 D2 D1 D0
LSUPIM LSCM NTM NLSM MLSM HLSM QLSM NSDM
Bit Symbol Description
D0 NSDM NO SIGNAL DETECT MASK: The mask bit for the No Signal Detect bit (NSD) of the Receive Condition Register A
(RCRA).
D1 QLSM QUIET LINE STATE MASK: The mask bit for the Quiet Line State bit (QLS) of the Receive Condition Register A
(RCRA).
D2 HLSM HALT LINE STATE MASK: The mask bit for the Halt Line State bit (HLS) of the Receive Condition Register A
(RCRA).
D3 MLSM MASTER LINE STATE MASK: The mask bit for the Master Line State bit (MLS) of the Receive Condition Register
A (RCRA).
D4 NLSM NOISE LINE STATE MASK: The mask bit for the Noise Line State bit (NLS) of the Receive Condition Register A
(RCRA).
D5 NTM NOISE THRESHOLD MASK: The mask bit for the Noise Threshold bit (NT) of the Receive Condition Register A
(RCRA).
D6 LSCM LINE STATE CHANGE MASK: The mask bit for the Line State Change bit (LSC) of the Receive Condition
Register A (RCRA).
D7 LSUPIM LINE STATE UNKNOWN AND PHY INVALID MASK: The mask bit for the Line State Unknown and PHY Invalid
bit (LSUPI) of the Receive Condition Register A (RCRA).
56
5.0 Registers (Continued)
5.13 RECEIVE CONDITION MASK REGISTER B (RCMRB)
The Receive Condition Mask Register B allows the user to dynamically select which events will generate an interrupt.
The Receive Condition B bit (RCB) of the Interrupt Condition Register (ICR) will be set to 1 when one or more bits within the
Receive Condition Register B (RCRA) is set to 1 and the corresponding mask bits in this register is also set to 1.
Since this register is cleared (i.e. set to 0) during the reset process, all interrupts are initially masked.
ACCESS RULES
ADDRESS READ WRITE
0Ch Always Always
D7 D6 D5 D4 D3 D2 D1 D0
RESM SILSM EBOUM CSEM LSUPVM ALSM STM ILSM
Bit Symbol Description
D0 ILSM IDLE LINE STATE MASK: The mask bit for the Idle Line State bit (ILS) of the Receive Condition Register B
(RCRB).
D1 STM STATE THRESHOLD MASK: The mask bit for the State Threshold bit (ST) of the Receive Condition Register B
(RCRB).
D2 ALSM ACTIVE LINE STATE MASK: The mask bit for the Active Line State bit (ALS) of the Receive Condition Register
B (RCRB).
D3 LSUPVM LINE STATE UNKNOWN AND PHY VALID MASK: The mask bit for the Line State Unknown and PHY Valid bit
(LSUPV) of the Receive Condition Register B (RCRB).
D4 CSEM CASCADE SYNCHRONIZATION ERROR MASK/CONNECTION SERVICE EVENT MASK:
The mask bit for the Cascade Synchronization Error/Connection service event bit (CSE) of the Receive Condition
Register B (RCRB).
D5 EBOUM ELASTICITY BUFFER OVERFLOW/UNDERFLOW MASK: The mask bit for the Elasticity Buffer Overflow/
Underflow bit (EBOU) of the Receive Condition Register B (RCRB).
D6 SILSM SUPER IDLE LINE STATE MASK: The mask bit for the Super Idle Line State bit (SILS) of the Receive Condition
Register B (RCRB).
D7 RESM RESERVED MASK: The mask bit for the Reserved bit (RES) of the Receive Condition Register B (RCRB).
57
5.0 Registers (Continued)
5.14 NOISE THRESHOLD REGISTER (NTR)
The Noise Threshold Register contains the start value for the Noise Timer. This threshold register is used in conjunction with the
Noise Prescale Threshold register for setting the maximum allowable time between entry to ILS, HLS, MLS, ALS, or NSD line
states. The Noise timer is used to implement the TNE timing requirement of PCM. The Noise timer decrements by one for every
80 x (NPTRa1) ns in case of Noise events. As a result, the internal noise counter takes the following amount of time to reach
zero:
((NPTRa1) x NTR aNPTR) x 80 ns
The threshold values for the Noise Counter and Noise Prescale Counter are simultaneously loaded into both counters if one of
the following conditions is true:
1. Both the Noise Counter and Noise Prescale Counter reach zero and the current Line State is either Noise Line State, Active
Line State, or Line State Unknown.
or
2. The current Line State is either Halt Line State, Idle Line State, Master Line State, Quiet Line State, or No Signal Detect.
or
3. The Noise Threshold Register or Noise Prescale Threshold Register goes through a Control Bus Interface write cycle.
In addition, the value of the Noise Prescale Threshold register is loaded into the Noise Prescale Counter if the Noise Prescale
Counter reaches zero.
The Noise Counter and Noise Prescale Counter will continue to count, without resetting or reloading the threshold values, if a
Line State change occurs and the new line state is either Noise Line State, Active Line State, or Line State Unknown.
When both the Noise Threshold Counter and Noise Counter both reach zero, the Noise Threshold bit of the Receive Condition
Register A will be set.
The recommended default value for the NTR register is 40h and for the NPTR register is F9h which corresponds to 1.3 ms as
specified in the ANSI standard.
ACCESS RULES
ADDRESS READ WRITE
0Dh Always Always
D7 D6 D5 D4 D3 D2 D1 D0
RES NT6 NT5 NT4 NT3 NT2 NT1 NT0
Bit Symbol Description
D0-D6 NT0-NT6 NOISE THRESHOLD BITk0-6l:Start value for the Noise Counter.
NT0 is the Least Significant Bit (LSB).
D7 RES RESERVED: Reserved for future use.
Note: Users are discouraged from using this bit. Write data is ignored since the reserved bit is permanently set to 0.
58
5.0 Registers (Continued)
5.15 NOISE PRESCALE THRESHOLD REGISTER (NPTR)
The Noise Prescale Threshold Register contains the start value for the Noise Prescale Timer. This threshold register is used in
conjunction with the Noise Threshold register for setting the maximum allowable time between entry to ILS, HLS, MLS, ALS, or
NSD. The Noise timer is used to implement the TNE timing requirement of PCM. The Noise Prescale threshold controls how
often the Noise timer is decremented. When the Noise Prescale Timer reaches zero, it reloads the count with the contents of the
Noise Prescale Threshold Register and also causes the Noise Timer to decrement.
The threshold values for the Noise Counter and Noise Prescale Counter are simultaneously loaded into both counters if one of
the following conditions is true:
1. Both the Noise Counter and Noise Prescale Counter reach zero and the current Line State is either Noise Line State, Active
Line State, or Line State Unknown.
or
2. The Current Line State is either Halt Line State. Idle Line State, Master Line State, Quiet Line State, or No Signal Detect
or
3. The Noise Threshold Register or Noise Prescale Threshold Register goes through a Control Bus Interface write cycle.
In addition, the value of the Noise Prescale Threshold Register is loaded into the Noise Prescale Counter if the Noise Prescale
Counter reaches zero.
The Noise Counter and Noise Prescale Counter will continue to count, without resetting or reloading the threshold values, if a
Line State change occurs and the new line state is either Noise Line State, Active Line State, or Line State Unknown.
When both the Noise Threshold Counter and Noise Counter both reach zero, the Noise Threshold bit of the Receive Condition
Register A will be set.
See the NTR register description for default value recommendations.
ACCESS RULES
ADDRESS READ WRITE
0Eh Always Always
D7 D6 D5 D4 D3 D2 D1 D0
NPT7 NPT6 NPT5 NPT4 NPT3 NPT2 NPT1 NPT0
Bit Symbol Description
D0-D7 NPT0-NPT7 NOISE PRESCALE THRESHOLD BITk0-7l:Start value for the Noise Prescale Timer.
NPT0 is the Least Significant Bit (LSB).
59
5.0 Registers (Continued)
5.16 CURRENT NOISE COUNT REGISTER (CNCR)
The Current Noise Count Register takes a snap-shot of the Noise Timer during every Control Bus Interface read cycle of this
register.
During a Control Bus Interface write cycle, the Control Bus Write Command Reject bit (CCR) of the Interrupt Condition Register
(ICR) will be set to 1 and will ignore a write cycle.
ACCESS RULES
ADDRESS READ WRITE
0Fh Always Write Reject
D7 D6 D5 D4 D3 D2 D1 D0
NCLSCD CNC6 CNC5 CNC4 CNC3 CNC2 CNC1 CNC0
Bit Symbol Description
D0D6 CNC0CNC6 CURRENT NOISE COUNT BIT k0–6l:Snapshot of the Noise Counter.
D7 NCLSCD NOISE COUNTER LINE STATE CHANGE DETECTION
60
5.0 Registers (Continued)
5.17 CURRENT NOISE PRESCALE COUNT REGISTER (CNPCR)
The Current Noise Prescale Count Register takes a snap-shot of the Noise Prescale Timer during every Control Bus Interface
read cycle of this register.
During a Control Bus Interface write cycle, the Control Bus Write Command Reject bit (CCR) of the Interrupt Condition Register
(ICR) will be set to 1 and will ignore a write cycle.
ACCESS RULES
ADDRESS READ WRITE
10h Always Write Reject
D7 D6 D5 D4 D3 D2 D1 D0
CNPC7 CNPC6 CNPC5 CNPC4 CNPC3 CNPC2 CNPC1 CNPC0
Bit Symbol Description
D0D7 CNPC07 CURRENT NOISE PRESCALE COUNT BIT k0–7l:Snapshot of the Noise Prescale Timer.
61
5.0 Registers (Continued)
5.18 STATE THRESHOLD REGISTER (STR)
The State Threshold Register contains the start value for the State Timer. This timer is used in conjunction with the State
Prescale Timer to count the Line State duration. The State Timer will decrement every 80 ns if the State Prescale Timer is zero
and the current Line State is Halt Line State, Idle Line State, Master Line State, Quiet Line State, or No Signal Detect. The State
Timer takes
((SPTRa1) x STR aSPTR) x 80 ns
to reach zero during a continuous line state condition.
The threshold values for the State Timer and State Prescale Timer are simultaneously loaded into both counters if one of the
following conditions is true:
1. Both the State Timer and State Prescale Timer reach zero and the current Line State is Halt Line State, Idle Line State,
Master Line State, Quiet Line State, or No Signal Detect.
or
2. A line state change occurs and the new Line State is Halt Line State, Idle Line State, Master Line State, Quiet Line State, or
No Signal Detect.
or
3. The State Threshold Register or State Prescale Threshold Register goes through a Control Bus Interface write cycle.
In addition, the value of the State Prescale Threshold Register is loaded into the State Prescale Counter if the State Prescale
Timer reaches zero.
The State Timer and State Prescale Timer will reset by reloading the threshold values, if a Line State change occurs and the
new Line State is Halt Line State, Idle Line State, Master Line State, Quiet Line State, or No Signal Detect. On detection of ALS,
NLS, or LSU the timer will not decrement.
ACCESS RULES
ADDRESS READ WRITE
11h Always Always
D7 D6 D5 D4 D3 D2 D1 D0
RES ST6 ST5 ST4 ST3 ST2 ST1 ST0
Bit Symbol Description
D0-D6 ST0-ST6 STATE THRESHOLD BITk0-6l:Start value for the State Timer.
ST0 is the Least Significant Bit (LSB).
D7 RES RESERVED: Reserved for future use.
Note: Users are discouraged from using this bit. Write data is ignored since the reserved bit is permanently set to 0.
62
5.0 Registers (Continued)
5.19 STATE PRESCALE THRESHOLD REGISTER (SPTR)
The State Prescale Threshold Register contains the start value for the State Prescale Timer. The State Prescale Timer is a down
counter. It is used in conjunction with the State Timer to count the Line State duration.
The threshold values for the State Timer and State Prescale Timer are simultaneously loaded into both timers if one of the
following conditions is true:
1. Both the State Timer and State Prescale Timer reach zero and the current Line State is Halt Line State, Idle Line State,
Master Line State, Quiet Line State, or No Signal Detect.
or
2. A Line State change occurs and the new Line State is Halt Line State, Idle Line State, Master Line State, Quiet Line State, or
No Signal Detect.
or
3. The State Threshold Register or State Prescale Threshold Register goes through a Control Bus Interface write cycle.
The State Prescale Timer will decrement every 80 ns if the current Line State is Halt Line State, Idle Line State, Master Line
State, Quiet Line State, or No Signal Detect.
ACCESS RULES
ADDRESS READ WRITE
12h Always Always
D7 D6 D5 D4 D3 D2 D1 D0
SPT7 SPT6 SPT5 SPT4 SPT3 SPT2 SPT1 SPT0
Bit Symbol Description
D0D7 SPT0SPT7 STATE PRESCALE THRESHOLD BIT k0–7l:Start value for the State Prescale Timer.
SPT0 is the Least Significant Bit (LSB).
63
5.0 Registers (Continued)
5.20 CURRENT STATE COUNT REGISTER (CSCR)
The Current State Count Register takes a snap-shot of the State Counter during every Control Bus Interface read cycle of this
register.
During a Control Bus Interface write cycle, the Control Bus Write Command Reject bit (CCR) of the Interrupt Condition Register
(ICR) will be set to 1 and will ignore a write cycle.
ACCESS RULES
ADDRESS READ WRITE
13h Always Write Reject
D7 D6 D5 D4 D3 D2 D1 D0
SCLSCD CSC6 CSC5 CSC4 CSC3 CSC2 CSC1 CSC0
Bit Symbol Description
D0D6 CSC0CSC6 CURRENT STATE COUNT BIT k0–6l:Snapshot of the State Counter.
D7 SCLSCD STATE COUNTER LINE STATE CHANGE DETECTION
64
5.0 Registers (Continued)
5.21 CURRENT STATE PRESCALE COUNT REGISTER (CSPCR)
The Current State Prescale Count Register takes a snap-shot of the State Prescale Counter during every Control Bus Interface
read cycle of this register.
During a Control Bus Interface write cycle, the Control Bus Write Command Reject bit (CCR) of the Interrupt Condition Register
(ICR) will be set to 1 and will ignore a write cycle.
ACCESS RULES
ADDRESS READ WRITE
14h Always Write Reject
D7 D6 D5 D4 D3 D2 D1 D0
CSPC7 CSPC6 CSPC5 CSPC4 CSPC3 CSPC2 CSPC1 CSPC0
Bit Symbol Description
D0D7 CSPC07 CURRENT STATE PRESCALE COUNT k0–7l:Snapshot of the State Prescale Counter.
65
5.0 Registers (Continued)
5.22 LINK ERROR THRESHOLD REGISTER (LETR)
The Link Error Threshold Register contains the start value for the Link Error Monitor Counter. It is an 8-bit down-counter which
decrements if link errors are detected.
When the Counter reaches 0, the Link Error Monitor Threshold Register value is loaded into the Link Error Monitor Counter and
the Link Error Monitor Threshold bit (LEMT) of the Interrupt Condition Register (ICR) is set to one.
The Link Error Monitor Threshold Register value is also loaded into the Link Error Monitor Counter during every Control Bus
Interface write cycle of LETR.
The counter is initialized to 0 during the reset process (i.e. ERSTeGND).
ACCESS RULES
ADDRESS READ WRITE
15h Always Always
D7 D6 D5 D4 D3 D2 D1 D0
LET7 LET6 LET5 LET4 LET3 LET2 LET1 LET0
Bit Symbol Description
D0D7 LET0LET7 LINK ERROR THRESHOLD BIT k0–7l:Start value for the Link Error Monitor Counter.
LET0 is the Least Significant Bit (LSB).
66
5.0 Registers (Continued)
5.23 CURRENT LINK ERROR COUNT REGISTER (CLECR)
The Current Link Error Count Register takes a snap-shot of the Link Error Monitor Counter during every Control Bus Interface
read cycle of this register.
During a Control Bus Interface write cycle, the Control Bus Write Command Reject bit (CCR) of the Interrupt Condition Register
(ICR) will be set to 1 and will ignore a write cycle.
ACCESS RULES
ADDRESS READ WRITE
16h Always Write Reject
D7 D6 D5 D4 D3 D2 D1 D0
LEC7 LEC6 LEC5 LEC4 LEC3 LEC2 LEC1 LEC0
Bit Symbol Description
D0D7 LEC0LEC7 LINK ERROR COUNT BIT k0–7l:Snapshot of the Link Error Monitor Counter.
67
5.0 Registers (Continued)
5.24 USER DEFINABLE REGISTER (UDR)
The User Definable Register is used to monitor and control events which are external to the PLAYERadevice.
The value of the Sense Bits reflect the asserted/deasserted state of their corresponding Sense pins. On the other hand, the
Enable bits assert/deassert the Enable pins.
Note: SB2 and EB2 are only effective for the DP83257.
ACCESS RULES
ADDRESS READ WRITE
17h Always Always
D7 D6 D5 D4 D3 D2 D1 D0
RES EB2 RES SB2 EB1 EB0 SB1 SB0
Bit Symbol Description
D0 SB0 SENSE BIT 0: This bit is set to 1 if the Sense Pin 0 (SP0) is asserted (i.e. SP0eVCC) for a minimum amount of
time. Once the asserted signal is latched, Sense Bit 0 can only be cleared through the Control Bus Interface, even
if the signal is deasserted. This ensures that the Control Bus Interface will record the source of events which can
cause interrupts in a traceable manner.
D1 SB1 SENSE BIT 1: This bit is set to 1 if the Sense Pin 1 (SP1) is asserted (i.e. SP1eVCC) for a minimum amount of
time. Once the asserted signal is latched, Sense Bit 1 can only be cleared through the Control Bus Interface, even
if the signal is deasserted. This ensures that the Control Bus Interface will record the source of events which can
cause interrupts in a traceable manner.
D2 EB0 ENABLE BIT 0: The Enable Bit 0 allows control of external logic through the Control Bus Interface. The User
Definable Enable Pin 0 (EP0) is asserted/deasserted by this bit.
0: EP0 is deasserted (i.e. EP0eGND).
1: EP0 is asserted (i.e. EP0eVCC).
D3 EB1 ENABLE BIT 1: This bit allows control of external logic through the Control Bus Interface. The User Definable
Enable Pin 0 (EP0) is asserted/deasserted by this bit.
0: EP1 is deasserted (i.e. EP1eGND).
1: EP1 is asserted (i.e. EP1eVCC).
D4 SB2 SENSE BIT 2: This bit is set to 1 if the Sense Pin 2 (SP2) is asserted (i.e. SP2eVCC) for a minimum amount of
time. Once the asserted signal is latched, Sense Bit 2 can only be cleared through the Control Bus Interface, even
if the signal is deasserted. This ensures that the Control Bus Interface will record the source of events which can
cause interrupts in a traceable manner.
Note: SB2 and EB2 are only effective for the DP83257.
D5 RES RESERVED: Reserved for future use. The reserved bit is set to 0 during the initialization process
(i.e. ERSTeGND).
Note: Users are discouraged from using this bit. It may be set or cleared without any effects to the functionality of the PLAYERadevice.
D6 EB2 ENABLE BIT2: The Enable Bit 2 allows control of external logic through the Control Bus Interface. The User
Definable Enable Pin 2 (EP2) is asserted/deasserted by this bit.
Note: SB2 and EB2 are only effective for the DP83257.
0: EP2 is deasserted (i.e. EP2eGND).
1: EP2 is asserted (i.e. EP2eVCC).
D7 RES RESERVED: Reserved for future use. The reserved bit is set to 0 during the initialization process
(i.e. ERSTeGND).
Note: Users are discouraged from using this bit. It may be set or cleared without any effects to the functionality of the PLAYERadevice.
68
5.0 Registers (Continued)
5.25 DEVICE ID REGISTER (IDR)
The Device ID Register contains the binary equivalent of the revision number for this device. It can be used to ensure proper
software and hardware versions are matched.
During a Control Bus Interface write cycle, the Control Bus Write Command Register bit (CCR) of the Interrupt Condition
Register (ICR) will be set to 1, and will ignore write cycle.
REVISION TABLE
IDR DEVICE DESCRIPTION
(hex)
10 PLAYERaRevision A
11 PLAYERaRevision B
ACCESS RULES
ADDRESS READ WRITE
18h Always Write Reject
D7 D6 D5 D4 D3 D2 D1 D0
DID7 DID6 DID5 DID4 DID3 DID2 DID1 DID0
Bit Symbol Description
D0D3 DID0DID3 DEVICE ID BIT k0-3l:Circuit enhancement revision number. Bit 3 is the MSB. The initial revision of the
PLAYERais equal to 0 and enhancements will increment this number.
D4D7 DID4DID7 DEVICE ID BIT k4-7l:Architecture level of the PHY device. Bit 7 is the MSB. The original PLAYER
device was equal to 0 and the PLAYERais equal to 1. This number will only be incremented after a
significant architectural change.
69
5.0 Registers (Continued)
5.26 CURRENT INJECTION COUNT REGISTER (CIJCR)
The Current Injection Count Register takes a snap-shot of the Injection Counter during every Control Bus Interface read cycle of
this register.
During a Control Bus Interface write cycle, the Control Bus Write Command Reject bit (CCR) of the Interrupt Condition Register
(ICR) will be set to 1 and will ignore a write cycle.
The Injection Counter is an 8-bit down-counter which decrements every 80 ns.
The counter is active only during One Shot or Periodic Injection Modes (i.e. Injection Controlk1:0lbits (ICk1:0l)ofthe
Current Transmit State Register (CTSR) are set to either 01 or 10).
The Injection Threshold Register (IJTR) value is loaded into the Injection Counter when the counter reaches zero and during
every Control Bus Interface write cycle of IJTR.
The counter is initialized to 0 during the reset process (i.e. ERSTeGND).
ACCESS RULES
ADDRESS READ WRITE
19h Always Write Reject
D7 D6 D5 D4 D3 D2 D1 D0
IJC7 IJC6 IJC5 IJC4 IJC3 IJC2 IJC1 IJC0
Bit Symbol Description
D0D7 IJC0IJC7 INJECTION COUNT BITk0-7l:Current value of the Injection Counter.
IJC0 is the Least Significant Bit (LSB).
70
5.0 Registers (Continued)
5.27 INTERRUPT CONDITION COMPARISON REGISTER (ICCR)
The Interrupt Condition Comparison Register ensures that the Control Bus must first read a bit modified by the PLAYERa
device before it can be written to by the Control Bus Interface.
The current state of the Interrupt Condition Register (ICR) is automatically written into the Interrupt Condition Comparison
Register (i.e. ICCReICR) during a Control Bus Interface read-cycle of ICR.
During a Control Bus Interface write cycle, the PLAYERadevice will set the Conditional Write Inhibit bit (CWI) of the Interrupt
Condition Register (ICR) to 1 and disallow the setting or clearing of a bit within ICR when the value of a bit in ICR differs from the
value of the corresponding bit in the interrupt Condition Comparison Register.
ACCESS RULES
ADDRESS READ WRITE
1Ah Always Always
D7 D6 D5 D4 D3 D2 D1 D0
UDIC RCBC RCAC LEMTC CWIC CCRC CPEC DPEC
Bit Symbol Description
D0 DPEC PHYÐREQUEST DATA PARITY ERROR COMPARISON: The comparison bit for the PHYÐRequest Data Parity
Error bit (DPE) of the Interrupt Condition Register (ICR).
D1 CPEC CONTROL BUS DATA PARITY ERROR COMPARISON: The comparison bit for the Control Bus Data Parity Error
bit (CPE) of the Interrupt Condition Register (ICR).
D2 CCRC CONTROL BUS WRITE COMMAND REJECT COMPARISON: The comparison bit for the Control Bus Write
Command Reject bit (CCR) of the Interrupt Condition Register (ICR).
D3 CWIC CONDITIONAL WRITE INHIBIT COMPARISON: The comparison bit for the Conditional Write Inhibit bit (CWI) of
the Interrupt Condition Register (ICR).
D4 LEMTC LINK ERROR MONITOR THRESHOLD COMPARISON: The comparison bit for the Link Error Monitor Threshold
bit (LEMT) of the Interrupt Condition Register (ICR).
D5 RCAC RECEIVE CONDITION A COMPARISON: The comparison bit for the Receive Condition A bit (RCA) of the
Interrupt Condition Register (ICR).
D6 RCBC RECEIVE CONDITION B COMPARISON: The comparison bit for the Receive Condition B bit (RCB) of the
Interrupt Condition Register (ICR).
D7 UDIC USER DEFINABLE INTERRUPT COMPARISON: The comparison bit for the User Definable Interrupt bit (UDIC) of
the Interrupt Condition Register (ICR).
71
5.0 Registers (Continued)
5.28 CURRENT TRANSMIT STATE COMPARISON REGISTER (CTSCR)
The Current Transmit State Comparison Register ensures that the Control Bus must first read a bit modified by the PLAYERa
device before it can be written to by the Control Bus Interface.
The current state of the Current Transmit State Register (CTSR) is automatically written into the Current Transmit State
Comparison Register A (i.e. CTSCReCTSR) during a Control Bus Interface read cycle of CTSR.
During a Control Bus Interface write cycle, the PLAYERadevice will set the Conditional Write Inhibit bit (CWI) of the Interrupt
Condition Register (ICR) to 1 and disallow the setting or clearing of a bit within the CTSR when the value of a bit in the CTSR
differs from the value of the corresponding bit in the Current Transmit State Comparison Register.
ACCESS RULES
ADDRESS READ WRITE
1Bh Always Always
D7 D6 D5 D4 D3 D2 D1 D0
RESC PRDPEC SEC IC1C IC0C TM2C TM1C TM0C
Bit Symbol Description
D0 TM0C TRANSMIT MODE k0lCOMPARISON: The comparison bit for the Transmit Mode k0lbit (TM0) of the
Current Transmit State Register (CTSR).
D1 TM1C TRANSMIT MODE k1lCOMPARISON: The comparison bit for the Transmit Mode k1lbit (TM1) of the
Current Transmit State Register (CTSR).
D2 TM2C TRANSMIT MODE k2lCOMPARISON: The comparison bit for the Transmit Mode k2lbit (TM2) of the
Current Transmit State Register (CTSR).
D3 IC0C INJECTION CONTROL k0lCOMPARISON: The comparison bit for the Injection Control k0lbit (IC0) of the
Current Transmit State Register (CTSR).
D4 IC1C INJECTION CONTROL k1lCOMPARISON: The comparison bit for the Injection Control k1lbit (IC1) of the
Current Transmit State Register (CTSR).
D5 SEC SMOOTHER ENABLE COMPARISON: The comparison bit for the Smoother Enable bit (SE) of the Current
Transmit State Register (CTSR).
D6 PRDPEC PHYÐREQUEST DATA PARITY ENABLE COMPARISON: The comparison bit for the PHYÐRequest Data
Parity Enable bit (PRDPE) of the Current Transmit State Register (CTSR).
D7 RESC RESERVED COMPARISON: The comparison bit for the Reserved bit (RES) of the Current Transmit State
Register (CTSR).
72
5.0 Registers (Continued)
5.29 RECEIVE CONDITION COMPARISON REGISTER A (RCCRA)
The Receive Condition Comparison Register A ensures that the Control Bus must first read a bit modified by the PLAYERa
device before it can be written to by the Control Bus Interface.
The current state of RCRA is automatically written into the Receive Condition Comparison Register A (i.e. RCCRAeRCRA)
during a Control Bus Interface read cycle of RCRA.
During a Control Bus Interface write cycle, the PLAYERadevice will set the Conditional Write Inhibit bit (CWI) of the Interrupt
Condition Register (ICR) to 1 and prevent the setting or clearing of a bit within RCRA when the value of a bit in RCRA differs
from the value of the corresponding bit in the Receive Condition Comparison Register A.
ACCESS RULES
ADDRESS READ WRITE
1Ch Always Always
D7 D6 D5 D4 D3 D2 D1 D0
LSUPIC LSCC NTC NLSC MLSC HLSC QLSC NSDC
Bit Symbol Description
D0 NSDC NO SIGNAL DETECT COMPARISON: The comparison bit for the No Signal Detect bit (NSD) of the Receive
Condition Register A (RCRA).
D1 QLSC QUIET LINE STATE COMPARISON: The comparison bit for the Quiet Line State bit (QLS) of the Receive
Condition Register A (RCRA).
D2 HLSC HALT LINE STATE COMPARISON: The comparison bit for the Halt Line State bit (HLS) of the Receive Condition
Register A (RCRA).
D3 MLSC MASTER LINE STATE COMPARISON: The comparison bit for the Master Line State bit (MLS) of the Receive
Condition Register A (RCRA).
D4 NLSC NOISE LINE STATE COMPARISON: The comparison bit for the Noise Line State bit (NLS) of the Receive
Condition Register A (RCRA).
D5 NTC NOISE THRESHOLD COMPARISON: The comparison bit for the Noise Threshold bit (NT) of the Receive
Condition Register A (RCRA).
D6 LSCC LINE STATE CHANGE COMPARISON: The comparison bit for the Line State Change bit (LSC) of the Receive
Condition Register A (RCRA).
D7 LSUPIC LINE STATE UNKNOWN AND PHY INVALID COMPARISON: The comparison bit for the Line State Unknown
and PHY Invalid bit (LSUPI) of the Receive Condition Register A (RCRA).
73
5.0 Registers (Continued)
5.30 RECEIVE CONDITION COMPARISION REGISTER B (RCCRB)
The Receive Condition Comparison Register B ensures that the Control Bus must first read a bit modified by the PLAYERa
device before it can be written to by the Control Bus Interface.
The current state of RCRB is automatically written into the Receive Condition Comparison Register B (i.e. RCCRBeRCRB)
during a Control Bus Interface read cycle RCRB.
During a Control Bus Interface write cycle, the PLAYERadevice will set the Conditional Write Inhibit bit (CWI) of the Interrupt
Condition Register (ICR) to 1 and prevent the setting or clearing of a bit within RCRB when the value of a bit in RCRB differs
from the value of the corresponding bit in the Receive Condition Comparison Register B.
ACCESS RULES
ADDRESS READ WRITE
1Dh Always Always
D7 D6 D5 D4 D3 D2 D1 D0
RESC SILSC EBOUC CSEC LSUPVC ALSC STC ILSC
Bit Symbol Description
D0 ILSC IDLE LINE STATE COMPARISON: The comparison bit for the Idle Line State bit (ILS) of the Receive Condition
Register B (RCRB).
D1 STC STATE THRESHOLD COMPARISON: The comparison bit for the State Threshold bit (ST) of the Receive
Condition Register B (RCRB).
D2 ALSC ACTIVE LINE STATE COMPARISON: The comparison bit for the Active Line State bit (ALS) of the Receive
Condition Register B (RCRB).
D3 LSUPVC LINE STATE UNKNOWN AND PHY VALID COMPARISON: The comparison bit for the Line State Unknown and
PHY Valid bit (LSUPV) of the Receive Condition Register B (RCRB).
D4 CSEC CONNECTION SERVICE EVENT COMPARISON / CASCADE SYNCHRONIZATION ERROR: The comparison
bit for the Cascade Synchronization Error/Connection Service Event bit (CSE) of the Receive Condition Register
B (RCRB).
D5 EBOUC ELASTICITY BUFFER OVERFLOW / UNDERFLOW COMPARISON: The comparison bit for the Elasticity Buffer
Overflow/Underflow bit (EBOU) of the Receive Condition Register B (RCRB).
D6 SILSC SUPER IDLE LINE STATE COMPARISON: The comparison bit for the Super Idle Line State bit (SILS) of the
Receive Condition Register B (RCRB).
D7 RESC RESERVED COMPARISON: The comparison bit for the Reserved bit (RES) of the Receive Condition Register B
(RCRB).
74
5.0 Registers (Continued)
5.31 MODE REGISTER 2 (MODE2)
The Mode Register 2 (MODE2) is used to configure the PLAYERadevice.
The register is used to software reset the chip, setup data parity, and enable scrubbing functions.
Note: This register can not be written to during reset.
ACCESS RULES
ADDRESS READ WRITE
1Eh Always Conditional
D7 D6 D5 D4 D3 D2 D1 D0
ESTC RES CLKSEL RES RES RES CBPE PHYRST
Bit Symbol Description
D0 PHYRST PLAYER RESET: This bit can be used as a master software reset of the PLAYER function within the
PLAYERadevice. The clock distribution and recovery sections of the chip are not affected by this reset.
The PLAYERaautomatically clears this bit 32 byte time after its assertion to indicate that the reset action
has been completed.
This bit can be set through a C-Bus write, but can only be cleared by the PLAYERa.
D1 CBPE C-Bus Parity Enable: This bit disables or enables parity checking on C-Bus data. When this bit is set to 0, no
parity checking is done. When the bit is set to 1, parity checking is enabled during a C-Bus write cycle. Should
a mismatch occur, the C-Bus Data Parity Error (ICR.CPE) bit will be set and the corresponding C-Bus access
is discarded.
C-Bus data parity is always generated during a C-Bus read cycle.
D2D4 RES RESERVED: Reserved for future use.
D5 CLKSEL CLOCK SELECT: This bit controls the frequency of the CLK16 output. It resets to 0 which sets the CLK16
output to a 15.625 MHz frequency. When set to 1 a 31.25 MHz frequency is generated.
Note: When the value of this bit is changed, no glitches appear on the CLK16 output due to the frequency change.
D6 RES RESERVED: Reserved for future use.
D7 ESTC ENABLE SCRUBBING on TRIGGER CONDITIONS: When ESTC is set to 1 and a Trigger Condition occurs
(as set in the TDR register), the Trigger Transition Configuration Register (TTCR) is loaded into the
Configuration Register (CR) and scrubbing is started on all indicate ports that have changed.
Scrubbing is accomplished by sending out 2 PhyÐInvalid symbols followed by ‘‘scrub’’symbol pairs for a time
defined by the Scrub Timer Threshold register.
75
5.0 Registers (Continued)
5.32 CMT CONDITION COMPARISON REGISTER (CMTCCR)
The CMT Condition Comparison Register (CMTCR) ensures that the Control Bus must first read a bit modified by the PLAYERa
device before it can be written to by the Control Bus Interface.
The current state of the CMT Condition Register (CMTCR) is automatically written into the CMT Condition Comparison Register
(CMTCR) (i.e. CMTCCR eCMTCR) during a Control Bus Interface read-cycle of CMTCR.
During a Control Bus Interface write cycle, the PLAYERadevice will set the Conditional Write Inhibit bit (CWI) of the Interrupt
Control Register (ICR) to 1 and disallow the setting or clearing of a bit within the CMTCR when the value of a bit in the CMTCR
differs from the value of the corresponding bit in the CMT Condition Comparison Register.
ACCESS RULES
ADDRESS READ WRITE
1Fh Always Always
D7 D6 D5 D4 D3 D2 D1 D0
TCOC STEC RES RES RES RES RES RES
Bit Symbol Description
D0-D5 RES RESERVED: Reserved for future use.
D6 STEC SCRUB TIMER EXPIRED COMPARISON: The comparison bit for the Scrub Timer Expire bit (STE) of the CMT
Condition Register (CMTCR).
D7 TCOC TRIGGER CONDITION OCCURRED COMPARISON: The comparison bit for the Trigger Condition Occurred
(TCO) bit of the CMT Condition Register (CMTCR).
76
5.0 Registers (Continued)
5.33 CMT CONDITION REGISTER (CMTCR)
The CMT Condition Register maintains a history of all CMT events and actions performed. The corresponding CMT Condition
Mask Register (CMTCMR) can be used to generate an interrupt. When the bits in both the CMTCMR and CMTCR are set, the
Receive Condition Register B’s Connection Service Event (RCRB.CSE) bit will be set.
ACCESS RULES
ADDRESS READ WRITE
20h Always Conditional
D7 D6 D5 D4 D3 D2 D1 D0
TCO STE RES RES RES RES RES RES
Bit Symbol Description
D0-D5 RES RESERVED: Reserved for future use.
D6 STE SCRUB TIMER EXPIRED: This bit is set to 1 when the Scrub Timer expires.
Note: When STE is set, the Configuration Register (CR) is protected.
D7 TCO TRIGGER CONDITION OCCURRED: This bit is set to 1 when a trigger condition is met. When a trigger occurs,
the values in the Trigger Transmit Mode (TDR.TTM2-0) are loaded into the Current Transmit Mode Register
(CTSR.TM2-0).
Note: When TCO is set, the Current Transmit State Register (CTSR) is protected.
77
5.0 Registers (Continued)
5.34 CMT CONDITION MASK REGISTER (CMTCMR)
This is the mask register for the CMT Condition Register (CMTCR). When the bits in both the CMTCMR and CMTCR are set, the
Receive Condition Register B’s Connection Service Event (RCRB.CSE) bit will be set.
ACCESS RULES
ADDRESS READ WRITE
21h Always Always
D7 D6 D5 D4 D3 D2 D1 D0
TCOM STEM RES RES RES RES RES RES
Bit Symbol Description
D0-D5 RES RESERVED: Reserved for future use.
D6 STEM SCRUB TIMER EXPIRED MASK: The mask bit for the Scrub Timer Expired (STE) bit of the CMT Condition
Register (CMTCR).
D7 TCOM TRIGGER CONDITION OCCURRED MASK: The mask bit for the Trigger Condition Occurred (TCO) bit of the
CMT Condition Register (CMTCR).
78
5.0 Registers (Continued)
5.35 RESERVED REGISTERS 22H23H (RR22HRR23H)
This register is reserved for future use.
DO NOT ACCESS THIS REGISTER
ACCESS RULES
ADDRESS READ WRITE
22h23h Always DO NOT WRITE
79
5.0 Registers (Continued)
5.36 SCRUB TIMER THRESHOLD REGISTER (STTR)
This is the threshold value of the internal scrub timer. It has a resolution of 40.96 ms and a maximum value of E10 ms. When
the scrub timer reaches zero, the Scrub Timer Expired (CMTCR.STE) bit is set.
Scrubbing is initiated when MODE2.ESTCe1 and a trigger condition occurs.
Writing to STTR during scrubbing will not affect the scrubbing action.
ACCESS RULES
ADDRESS READ WRITE
24h Always Always
D7 D6 D5 D4 D3 D2 D1 D0
STT7 STT6 STT5 STT4 STT3 STT2 STT1 STT0
Bit Symbol Description
D0D7 STT0STT7 SCRUB TIMER THRESHOLD BITk0-7l:Scrub Timer threshold.
STT0 is the Least Significant Bit (LSB).
80
5.0 Registers (Continued)
5.37 SCRUB TIMER VALUE REGISTER (STVR)
This is a snap-shot of the current value of the upper 8 bits of the scrub timer.
During a Control Bus Interface write cycle, the Control Bus Write Command Reject bit (CCR) of the Interrupt Condition Register
(ICR) will be set to 1 and will ignore a write cycle.
ACCESS RULES
ADDRESS READ WRITE
25h Always Write Reject
D7 D6 D5 D4 D3 D2 D1 D0
STV7 STV6 STV5 STV4 STV3 STV2 STV1 STV0
Bit Symbol Description
D0D7 STV0STV7 SCRUB TIMER VALUE BITk0-7l:Snap-shot of the scrub timer.
STV0 is the Least Significant Bit (LSB).
81
5.0 Registers (Continued)
5.38 TRIGGER DEFINITION REGISTER (TDR)
This register determines which events cause a trigger transition and which transmit mode is entered when a trigger transition is
detected. The trigger transmit modes are the same as those found in the Current Transmit State Register (CTSR), and are
loaded from the TDR into the CTSR when any of the selected trigger conditions occur. When a trigger condition occurs
CMTCR.TCO is set.
The Trigger Definition Register is useful to implement the strict PCÐReact time requirement.
ACCESS RULES
ADDRESS READ WRITE
26h Always Always
D7 D6 D5 D4 D3 D2 D1 D0
TONT TOQLS TOHLS TOMLS TOSILS TTM2 TTM1 TTM0
Bit Symbol Description
D0, TTM0, TRIGGER TRANSMIT MODE k0, 1, 2l:These bits select one of 6 transmission modes to be loaded into the
Current Transmit State Register (CTSR) when a trigger condition is detected. The trigger condition is selected by
D1, TTM1,
the upper 5 bits of this register.
D2 TTM2
TTM2 TTM1 TTM0
000Active Transmit Mode (ATM): Normal transmission of incoming PHY Request data.
001Idle Transmit Mode (ITM): Transmission of Idle symbol pairs (11111 11111).
010Off Transmit Mode (OTM): Transmission of Quiet symbol pairs (00000 00000) and
deassertion of the PMD transmitter Enable pin (TXE).
011Reserved: Reserved for future use. Users are discouraged from using this transmit
mode. If selected, however, the transmitter will generate Quiet symbol pairs
(00000 00000).
100Master Transmit Mode (MTM): Transmission of Halt and Quiet symbol pairs
(00100 00000).
101Halt Transmit Mode (HTM): Transmission of Halt symbol pairs (00100 00100).
110Quiet Transmit Mode (QTM): Transmission of Quiet symbol pairs (00000 00000).
111Reserved: Reserved for future use. Users are discouraged from using this transmit
mode. If selected, however, the transmitter will generate Quiet symbol pairs
(00000 00000).
D3 TOSILS TRIGGER ON SILS: Trigger when SILS is received.
D4 TOMLS TRIGGER ON MLS: Trigger when MLS is received.
D5 TOHLS TRIGGER ON HLS: Trigger when HLS is received.
D6 TOQLS TRIGGER ON QLS (or NSD): Trigger when QLS is received.
D7 TONT TRIGGER ON Noise Threshold: Trigger when Noise Threshold is reached (Current Noise Registere0).
82
5.0 Registers (Continued)
5.39 TRIGGER TRANSITION CONFIGURATION REGISTER (TTCR)
The Trigger Transition Configuration Register holds the configuration switch setting to be loaded into the Configuration Register
(CR) when a trigger transition takes place. When scrubbing is enabled, scrubbing is performed for a period of time indicated by
the Scrub Timer Threshold Register (STTR).The register bit descriptions for the Configuration Register and, therefore, the
Trigger Transition Configuration Register are reprinted below.
ACCESS RULES
ADDRESS READ WRITE
27h Always Always
D7 D6 D5 D4 D3 D2 D1 D0
BIE AIE TRS1 TRS0 BIS1 BIS0 AIS1 AIS0
Bit Symbol Description
D0, D1 AIS0, AIS1 AÐINDICATE SELECTOR k0, 1l:The AÐIndicate Selector k0, 1lbits selects one of the four
Configuration Switch data buses for the AÐIndicate output port (AIP, AIC, AIDk7:0l).
AIS1 AIS0
0 0 PHY Invalid Bus
0 1 Receiver Bus
10A
Ð
Request Bus
11B
Ð
Request Bus
D2, D3 BIS0, BIS1 BÐINDICATE SELECTOR k0, 1l:The BÐIndicate Selector k0, 1lbits selects one of the four
Configuration Switch data buses for the BÐIndicate output port (BIP, BIC, BIDk7:0l).
BIS1 BIS0
0 0 PHY Invalid Bus
0 1 Receiver
10A
Ð
Request Bus
11B
Ð
Request Bus
Note: Even though this bit can be set and/or cleared in the DP83256 (for single path stations), it will not affect any I/Os since the
DP83256 does not offer a BÐIndicate port.
D4, D5 TRS0, TRS1 TRANSMIT REQUEST SELECTOR k0, 1l:The Transmit Request Selector k0, 1lbits selects one of
the four Configuration Switch data buses for the input to the Transmitter Block.
TRS1 TRS0
0 0 PHY Invalid Bus
0 1 Receiver Bus
10A
Ð
Request Bus
11B
Ð
Request Bus
Note: If the PLAYERadevice is in Active Transmit Mode (i.e. the Transmit Mode bits (TMk2:0l) of the Current Transmit State
Register (CTSR) are set to 00) and the PHY Invalid Bus is selected, then the PLAYERadevice will transmit continuous Idle
symbols due to the Repeat Filter.
D6 AIE AÐINDICATE ENABLE:
0: Disables the AÐIndicate output port. The AÐIndicate port pins will be tri-stated when the port is
disabled.
1: Enables the AÐIndicate output port (AIP, AIC, AIDk7:0l).
D7 BIE BÐINDICATE ENABLE:
0: Disables the BÐIndicate output port. The BÐIndicate port pins will be tri-stated when the port is
disabled.
1: Enables the BÐIndicate output port (BIP, BIC, BIDk7:0l).
Note: Even though this bit can be set and/or cleared in the DP83256 (for single path stations), it will not affect any I/Os since the
DP83256 does not offer a BÐIndicate port.
83
5.0 Registers (Continued)
5.40 RESERVED REGISTERS 28H-3AH (RR28H-RR3AH)
These registers are reserved for future use.
DO NOT ACCESS THESE REGISTERS
ACCESS RULES
ADDRESS READ WRITE
28h3Ah Always DO NOT WRITE
84
5.0 Registers (Continued)
5.41 CLOCK GENERATION MODULE REGISTER (CGMREG)
This register is used to enable or disable the 125 MHz ECL Transmit clock outputs. These outputs are not required for use in a
standard FDDI board implementation and are disabled by default to reduce high frequency noise.
These TXC outputs are included for support of alternate FDDI PMDs, such as unshielded twisted pair copper cable.
DO NOT WRITE TO RESERVED REGISTER BITS. Writes to reserved register bits could prevent proper device operation.
Therefore, read the register first, and then write it back with the non-reserved bits set to the desired value.
ACCESS RULES
ADDRESS READ WRITE
3Bh Always Always
D7 D6 D5 D4 D3 D2 D1 D0
RES RES FLTREN RES TXCE RES RES RES
Bit Symbol Description
D0-D2 RES RESERVED BITS: DO NOT CHANGE THE VALUE OF THESE BITS. Changes to reserved register bits could
prevent proper device operation.
D3 TXCE TRANSMIT CLOCK ENABLE: When bit is set to 1, 125 MHz ECL TXC outputs are enabled. When this bit is
reset to 0, TXC outputs are disabled. TXC outputs are disabled on reset.
Note: TXC clocks are only available on the 160-pin DP83257 PLAYERadevice.
D4 RES RESERVED BITS: DO NOT CHANGE THE VALUE OF THESE BITS. Changes to reserved register bits could
prevent proper device operation.
D5 FLTREN FILTER ENABLE: When bit is set to 1, the internal loop filter node is connected to the LPFLTR pin for
diagnostic viewing. This bit is reset to 0 by default, which disconnects the filter node from the LPFLTR pin.
Note: In normal operation this bit should be disabled (e0).
D6-D7 RES RESERVED BITS: DO NOT CHANGE THE VALUE OF THESE BITS. Changes to reserved register bits could
prevent proper device operation.
85
5.0 Registers (Continued)
5.42 ALTERNATE PMD REGISTER (APMDREG)
This register is used to enable or disable the Alternate PMD inputs and ouputs. These signals are not required for use in FDDI
board implementations that do not require a scrambler that is external to the PLAYERadevice. The actual interface consists of
the signal pairs RXCÐOUT, RXDÐOUT, RXCÐIN, and RXDÐIN.
The interface is disabled by default and should only be enabled if it is being used. Note that Long Internal Loopback should not
be used when the Alternate PMD Interface is enabled.
DO NOT WRITE TO RESERVED REGISTER BITS. Writes to reserved register bits could prevent proper device operation.
Therefore, read the register first, and then write it back with the non-reserved bits set to the desired value.
Note: The Alternate PMD Interface pins are only available on the 100-pin DP83256-AP and 160-pin DP83257 PLAYERadevices. The Alternate PMD Interface is
disabled on reset.
ACCESS RULES
ADDRESS READ WRITE
3Ch Always Always
D7 D6 D5 D4 D3 D2 D1 D0
RES RES RES RES APMDEN RES RES RES
Bit Symbol Description
D0D2 RES RESERVED BITS: DO NOT CHANGE THE VALUE OF THESE BITS. Changes to reserved register bits could
prevent proper device operation.
D3 APMDEN ALTERNATE PMD ENABLE: When bit is set to 1, the Alternate PMD Interface is enabled. When this bit is
reset to 0, the Alternate PMD Interface is disabled.
The Alternate PMD Interface consists of the following extra ECL signal pairs
RXCÐOUT, RXDÐOUT, RXCÐIN, and RXDÐIN.
In some alternate PMD implementations it may also be necessary to use the 125 MHz Transmit Clock
signals (TXC). The TXC outputs must be separately enabled by the TXCE bit in the CGMREG register.
Note: The Alternate PMD Interface pins are only available on the 100-pin DP83256-AP and 160-pin DP83257 PLAYERadevices. The
Alternate PMD Interface is disabled on reset.
D4D7 RES RESERVED BITS: DO NOT CHANGE THE VALUE OF THESE BITS. Changes to reserved register bits could
prevent proper device operation.
86
5.0 Registers (Continued)
5.43 GAIN REGISTER (GAINREG)
The Gain Register contains the settings for the CGM’s on-chip programmable loop filter. For optimal jitter performance on the
revision A and B PLAYERadevice’s Filter Position 4 should be used. The user should check that the IDR register is equal to
revision A or B (10h or 11h) before changing the filter setting as later revisions will default to the correct setting which may be a
different filter position number.
Pseudo Code Programming Example:
Care must be taken when changing the settings of the on-chip programmable loop filter. The filter should only be set to the
recommended value and the additional bits in the Gain Register must not be altered. Alteration of the reserved bits in the Gain
Register may result in improper PLAYERadevice operation.
The following pseudo code outlines the proper procedure for setting the Gain Register loop filter settings to the correct value.
// Register names and constants are all in UPPERCASE
//
//
#define REV B 0x11
#define REV A 0x10
#define LOOP MASK 0x1F
#define NEW LOOP 0x40
if (IDR k4REV B) À
temp 4GAIN REG
temp 4temp & LOOP MASK
temp 4temp
l
NEW LOOP
GAIN REG 4temp
Ó
else ÀDo NothingÓ
ACCESS RULES
ADDRESS READ WRITE
3Dh Always Always
D7 D6 D5 D4 D3 D2 D1 D0
FILT2 FILT1 FILT0 RES RES RES RES RES
Bit Symbol Description
D0D4 RES RESERVED: Do not alter these bits. The device may cease to operate properly if these bits are
changed.
D5–D7 FILT0,
FILT2
FILT1,
FILTER SELECTION k0, 1, 2l:The Filter Selection k0, 1, 2lbits select one of five on-chip CGM
loop filters.
Note: Filter combinations that are not specified or recommended should not be used and may result in non-optimal device
performance.
FILT2 FILT1 FILT0
1 1 0 FP0: Filter Position 0.
1 1 1 FP1: Filter Position 1.
0 0 0 FP2: Filter Position 2. This is the filter selected after reset on the
revision A and B PLAYERadevices.
0 0 1 FP3: Filter Position 3.
0 1 0 FP4: Filter Position 4. This is the recommended filter position for
the revision A and B PLAYERadevices.
87
5.0 Registers (Continued)
5.44 RESERVED REGISTERS 3EH-3FH (RR3EH-RR3FH)
These registers are reserved for future use.
DO NOT ACCESS THESE REGISTERS
ACCESS RULES
ADDRESS READ WRITE
3Eh3Fh Always DO NOT WRITE
88
6.0 Signal Descriptions
6.1 DP83256VF PIN DESCRIPTIONS
The pin descriptions for the DP83256VF are divided into 5 functional interfaces: PMD Interface, PHY Port Interface, Control Bus
Interface, Clock Interface, and Miscellaneous Interface.
For a Pinout Summary list, refer to Table 8-1 and
Figure 8-1
, DP83256VF 100-Pin JEDEC Metric PQFP Pinout.
PMD INTERFACE
The PMD Interface consists of I/O signals used to connect the PLAYERadevice to the Physical Medium Dependant (PMD)
sublayer.
Symbol Pin ÝI/O Description
PMIDa39 I PMD Indicate Data: Differential, 100k ECL, 125 Mbps serial data input signals from the PMD receiver.
PMIDb38
PMRDa33 O PMD Request Data: Differential, 100k ECL, 125 Mbps serial data output signals to the PMD transmitter.
PMRDb32
SDa37 I Signal Detect: Differential 100k ECL input signals from the PMD receiver indicating that a signal is being
received by the PMD receiver.
SDb36
TEL 47 I PMD Transmitter Enable Level: A TTL input signal to select the PMD transmitter Enable (TXE) signal
level.
TXE 46 O PMD Transmitter Enable: A TTL output signal to enable/disable the PMD transmitter. The output level
of the TXE pin is determined by three parameters: the Transmit Enable (TE) bit in the Mode Register, the
TM2-TM0 bits in the Current Transmit State Register, and the input to the TEL pin. The following rules
summarize the output of the TXE pin:
1. If TEe0 and TELeGND, then TXEeVCC
2. If TEe0 and TELeVCC, then TXEeGND
3. If TEe1 and OTM and TELeGND, then TXEeVCC
4. If TEe1 and OTM and TELeVCC, then TXEeGND
5. If TEe1 and not OTM and TELeGND, then TXEeGND
6. If TEe1 and not OTM and TELeVCC, then TXEeVCC
89
6.0 Signal Descriptions (Continued)
PHY PORT INTERFACE
The PHY Port Interface consists of I/O signals used to connect the PLAYERadevice to the Media Access Control (MAC)
sublayer or other PLAYERadevice. The DP83256 Device has two PHY Port Interfaces. The AÐIndicate path from one PHY
Port Interface and the BÐRequest path from the second PHY Port Interface. Each path consists of an odd parity bit, a control
bit, and two 4-bit symbols.
Refer to section 3.3, the Configuration Switch, for more information.
Symbol Pin ÝI/O Description
AIP 6 O PHY Port A Indicate Parity: A TTL output signal representing odd parity for the 10-bit wide Port A
Indicate signals (AIP, AIC, and AIDk7:0l).
AIC 7 O PHY Port A Indicate Control: TTL output signal indicating that the two 4-bit symbols (AIDk7:4land
AIDk3:0l) are either control symbols (AICe1) or data symbols (AICe0).
AID7 8 O PHY Port A Indicate Data: TTL output signals representing the first 4-bit data/control symbol.
AID6 9 AID7 is the most significant bit and AID4 is the least significant bit of the first symbol.
AID5 10
AID4 13
AID3 14 O PHY Port A Indicate Data: TTL output signals representing the second 4-bit data/control symbol.
AID2 15 AID3 is the most significant bit and AID0 is the least significant bit of the second symbol.
AID1 16
AID0 17
BRP 70 I PHY Port B Request Parity: A TTL input signal representing odd parity for the 10-bit wide Port A
Request signals (BRP, BRC, and BRDk7:0l).
BRC 69 I PHY Port B Request Control: A TTL input signal indicating that the two 4-bit symbols
(BRDk7:4land BRDk3:0l) are either control symbols (BRCe1) or data symbols (BRCe0).
BRD7 68 I PHY Port B Request Data: TTL input signals representing the first 4-bit data/control symbol.
BRD6 67 BRD7 is the most significant bit and BRD4 is the least significant bit of the first symbol.
BRD5 66
BRD4 63
BRD3 62 I PHY Port B Request Data: TTL input signals representing the second 4-bit data/control symbol.
BRD2 61 BRD3 is the most significant bit and BRD0 is the least significant bit of the second symbol.
BRD1 60
BRD0 59
90
6.0 Signal Descriptions (Continued)
CONTROL BUS INTERFACE
The Control Bus Interface consists of I/O signals used to connect the PLAYERadevice to Station Management (SMT).
The Control Bus is an asynchronous interface between the PLAYERadevice and a general purpose microprocessor or other
controller. It provides access to 64 8-bit internal registers.
In the PLAYERadevice the Control Bus address range has been expanded by 1-bit to 6 bits of address space.
Symbol Pin ÝI/O Description
ECE 73 I Control Enable: An active-low, TTL, input signal which enables the Control Bus port for a read or write
cycle. R/EW, CBAk5:0l, CBP, and CBDk7:0lmust be valid at the time ECE is low.
R/EW72 IRead/EWrite: A TTL input signal which indicates a read Control Bus cycle(R/EWe1), or a write
Control Bus cycle (R/EWe0).
EACK 75 O EAcknowledge: An active low, TTL, open drain output signal which indicates the completion of a read
or write cycle. During a read cycle, CBDk7:0lare valid as long as EACK is low (EACKe0). During a
write cycle, a microprocessor must hold CBDk7:0lvalid until EACK becomes low. Once EACK is low,
it will remain low as long as ECE remains low (ECEe0).
EINT 74 O EInterrupt: An active low, open drain, TTL, output signal indicating that an interrupt condition has
occurred. The Interrupt Condition Register (ICR) should be read in order to find out the source of the
interrupt. Interrupts can be masked through the use of the Interrupt Condition Mask Register (ICMR).
CBA5 83 I Control Bus Address: TTL input signals used to select the address of the register to be read or written.
CBA4 82 CBA5 is the most significant bit (MSB) and CBA0 is the least significant bit (LSB) of the address signals.
CBA3 81
CBA2 80
CBA1 77
CBA0 76
CBP 96 I/O Control Bus Parity: A bidirectional, TTL signal representing odd parity for the Control Bus data
(CBDk7:0l).
During a read cycle, the signal is held valid by the PLAYERadevice as long as EACK is low.
During a write cycle, the signal must be valid when ECE is low, and must be held valid until EACK
becomes low. If incorrect parity is used during a write cycle, the PLAYERadevice will inhibit the write
cycle and set the Control Bus Data Parity Error (CPE) bit in the Interrupt Condition Register (ICR).
CBD7 95 I/O Control Bus Data: Bidirectional, TTL signals containing the data to be read from or written to a register.
CBD6 94 During a read cycle, the signal is held valid by the PLAYERadevice as long as EACK is low.
CBD5 93
During a write cycle, the signal must be valid when ECE is low, and must be held valid until EACK
CBD4 92
becomes low.
CBD3 91
CBD2 90
CBD1 89
CBD0 86
91
6.0 Signal Descriptions (Continued)
CLOCK INTERFACE
The Clock Interface consists of 12.5 MHz and 25 MHz clocks supplied by the PLAYERadevice as well as reference and
feedback inputs.
Symbol Pin ÝI/O Description
LBC1 4 O Local Byte Clock: TTL compatible, 12.5 MHz, 50% duty cycle clock outputs which are phase
locked to a crystal oscillator or reference signal. The PHÐSEL input determines whether the five
LBC2 3
phase outputs are phase offset by 8 ns or 16 ns.
LBC3 2
LBC4 1
LBC5 100
PHÐSEL 22 I Phase Select: TTL compatible input used to select eithera8nsor16nsphase offset between the 5
local byte clocks (LBC’s). The LBC’s are phase offset 8ns apart when PHÐSEL is at a logic LOW
level and 16 ns apart when at a logic HI level.
FBKÐIN 25 I Feedback Input: TTL compatible input for use as the PLL’s phase comparator feedback input to
close the Phase Locked Loop. This input is intended to be driven from one of the Local Byte Clocks
(LBC’s) from the same PLAYERadevice.
LSC 99 O Local Symbol Clock: TTL compatible 25 MHz output for driving the MACSI or BMAC devices. This
output’s negative phase transition is aligned with the LBC1 output transitions and has a 40% HI and
60% LOW duty cycle.
CLK16 5 O Clock 16/32: TTL compatible clock with a selectable frequency of approximately 15.625 MHz or
31.25 MHz. The frequency can be selected using the Clock Select (CLKSEL) bit of the Mode 2
Register (MODE2).
Note: No glitches appear at the output when switching frequencies.
XTALÐIN 27 I External Crystal Oscillator Input: This input in conjunction with the XTALÐOUT output, is
designed for use of an external crystal oscillator network as the frequency reference for the clock
generation module’s internal VCO. A diagram of the required circuit, which includes only a 12.5 MHz
crystal and 2 loading capacitors, is shown in
Figure 3-19
.
This input is selected when the REFÐSEL input is at a logic LOW level. When not being used, this
input should be tied to ground.
XTALÐOUT 26 O External Crystal Oscillator Output: This output in conjunction with the XTALÐIN input, is designed
for use of an external crystal oscillator network as the frequency reference for the clock generation
module’s internal VCO. A diagram of the required circuit, which includes only a 12.5 MHz crystal and
2 loading capacitors, is shown in
Figure 3-19
.
REFÐIN 24 I Reference Input: TTL compatible input for use as the PLL’s phase comparator reference frequency.
This input is for use in dual attach station or concentrator configurations where there are multiple
PLAYERadevices at a given site requiring synchronization.
This input is selected when the REFÐSEL input is at a logic HI level.
REFÐSEL 23 I Reference Select: TTL compatible input which selects either the crystal oscillator inputs XTALÐIN
and XTALÐOUT or the REFÐIN inputs as the reference frequency inputs for the PLL.
The crystal oscillator inputs are selected when REFÐSEL is at a logic LOW level and the REFÐIN
input is selected as the reference when REFÐSEL is at a logic HI level.
LPFLTR 30 O Loop Filter: This is a diagnostic output that allows monitoring of the clock generation module’s filter
node. This output is disabled by default and does not need to be connected to any external device. It
can be enabled using the FLTREN bit of the Clock generation module register (CGMREG).
Note: In normal operation this pin should be disabled.
92
6.0 Signal Descriptions (Continued)
MISCELLANEOUS INTERFACE
The Miscellaneous Interface consist of a reset signal, user definable sense signals, and user definable enable signals.
Symbol Pin ÝI/O Description
ERST 71 I Reset: An active low, TTL, input signal which clears all registers. The signal must be kept asserted for a
minimum amount of time. Once the ERST signal is asserted, the PLAYERadevice should be allowed
the specified amount of time to reset internal logic. Note that bit zero of the Mode Register will be set to
zero (i.e. Stop Mode). See section 4.2, Stop Mode of Operation for more information
SP0 40 I User Definable Sense Pin 0: A TTL input signal from a user defined source. Sense Bit 0 (SB0) of the
User Definable Register (UDR) will be set to one if the signal is asserted for a minimum of 160 ns. Once
the asserted signal is latched, Sense Bit 0 can only be cleared through the Control Bus Interface, even if
the signal is deasserted. This ensures that the Control Bus Interface will record the source of events
which can cause interrupts.
SP1 42 I User Definable Sense Pin 1: A TTL input signal from a user defined source. Sense Bit 1 (SB1) of the
User Definable Register (UDR) will be set to one if the signal is asserted for a minimum of 160 ns. Once
the asserted signal is latched, Sense Bit 1 can only be cleared through the Control Bus Interface, even if
the signal is deasserted. This ensures that the Control Bus Interface will record the source of events
which can cause interrupts.
EP0 41 O User Definable Enable Pin 0: A TTL output signal allowing control of external logic through the Control
Bus Interface. EP0 is asserted/deasserted through Enable Bit 0 (EB0) of the User Definable Register
(UDR). When Enable Bit 0 is set to zero, EP0 is deasserted. When Enable Bit 0 is set to one, EP0 is
asserted.
EP1 43 O User Definable Enable Pin 1: A TTL output signal allowing control of external logic through the Control
Bus Interface. EP1 is asserted/deasserted through Enable Bit 1 (EB1) of the User Definable Register
(UDR). When Enable Bit 1 is set to zero, EP1 is deasserted. When Enable Bit 1 is set to one, EP1 is
asserted.
93
6.0 Signal Descriptions (Continued)
POWER AND GROUND
All power pins should be connected to a single a5V power supply using the recommended filtering. All ground pins should be
connected to a common 0V ground supply. Bypassing and filtering requirements are given in a separate User Information
Document.
Symbol Pin ÝI/O Description
VCCÐANALOG 20 Power: Positive 5V power supply for the PLAYERadevice’s CGM VCO.
GNDÐANALOG 21 Ground: Power supply return for the PLAYERadevice’s CGM VCO.
VCCÐCORE 88 Power: Positive 5V power supply for the core PLAYER section logic gates.
GNDÐCORE 87 Ground: Power supply return for the core PLAYER section logic gates.
VCCÐECL 31, Power: Positive 5V power supply for the PLAYERadevice’s ECL logic gates.
34,
44,
56
GNDÐECL 35, Ground: Power supply return for the PLAYERadevice’s ECL logic gates.
45,
55
VCCÐESD 28 Power: Positive 5V power supply for the PLAYERadevice’s ESD protection circuitry.
GNDÐESD 29 Ground: Power supply return for the PLAYERadevice’s ESD protection circuitry.
VCCÐIO 11, Power: Positive 5V power supply for the input/output buffers.
65,
79,
98
GNDÐIO 12, Ground: Power supply return for the input/output buffers.
64,
78,
97
SPECIAL CONNECT PINS
These are pins that have special connection requirements.
No Connect (N/C) pins should not be connected to anything. This means not to power, not to ground, and not to each other.
ReservedÐ0 (RESÐ0) pins must be connected to ground. These pins are not used to supply device power so they do not need
to be filtered or bypassed.
ReservedÐ1 (RESÐ1) pins must be connected to power. These pins are not used to supply device power so they do not need
to be filtered or bypassed.
Symbol Pin ÝI/O Description
N/C 49, 54 No Connect: Pins should not be connected to anything. This means not to power, not to ground, and
not to each other.
RESÐ0 18, 19, Reserved 0: Pins must be connected to ground. These pins are not used to supply device power so
they do not need to be filtered or bypassed.
48, 50,
51, 52,
53, 57,
58, 84
RESÐ185 Reserved 1: Pins must be connected to power. These pins are not used to supply device power so they
do not need to be filtered or bypassed.
94
6.0 Signal Descriptions (Continued)
6.2 DP83256VF-AP SIGNAL DESCRIPTIONS
The pin descriptions for the DP83256VF-AP are divided into five functional interfaces; PMD Interface, PHY Port Interface,
Control Bus Interface, Clock Interface, and Miscellaneous Interface.
For a Pinout Summary List, refer to Table 8-2 and
Figure 8-2
, DP83256VF-AP 100-Pin JEDEC Metric PQFP Pinout.
PMD INTERFACE
The PMD Interface consists of I/O signals used to connect the PLAYERadevice to the Physical Medium Dependant (PMD)
sublayer.
The DP83256VF-AP PLAYERadevice actually has two PMD interfaces. The Primary PMD Interface and the Alternate PMD
Interface.
The Primary PMD Interface should be used for all PMD implementations that do not require an external scrambler/descrambler
function, clock recovery function, or clock generation function, such as a Fiber Optic or Shielded Twisted Pair (SDDI) PMD. The
second, Alternate PMD Interface can be used to support Unshielded Twisted Pair (UTP) PMDs that require external scrambling,
with no external clock recovery or clock generation functions required.
Section 3.8 describes how the PLAYERacan be connected to the PMD and how the Alternate PMD can be enabled.
Note that when the Alternate PMD Interface is not being used, the pins that make up the interface must be connected in the
specific way described in the following Alternate PMD Interface table.
Primary PMD Interface
Symbol Pin ÝI/O Description
PMIDa42 I PMD Indicate Data: Differential, 100k ECL, 125 Mbps serial data input signals from the PMD Receiver
into the Clock Recovery Module (CRM) of the PLAYERa.
PMIDb41
PMRDa34 O PMD Request Data: Differential, 100k ECL, 125 Mbps serial data output signals to the PMD transmitter.
PMRDb33
SDa40 I Signal Detect: Differential 100k ECL input signals from the PMD receiver indicating that a signal is being
received by the PMD receiver.
SDb39
95
6.0 Signal Descriptions (Continued)
Alternate PMD Interface
Symbol Pin ÝI/O Description
PMIDa42 I PMD Indicate Data: Differential, 100k ECL, 125 Mbps serial data input signals from the PMD
Receiver into the Clock Recovery Module (CRM) of the PLAYERa.
PMIDb41
RXCÐOUTa36 O Recovered Clock Out: 125 MHz clock recovered by the Clock Recovery Module (CRM) from the
PMID data input.
RXCÐOUTb35
These signals are only active when the Alternate PMD Enable (APMDEN) bit of the Alternate PMD
Register (APMDREG) is set to a 1 and are off by default after Reset.
When these two pins are not used they should be left Not Connected (N/C).
RXDÐOUTa52 O Recovered Data Out: 125 Mbps data recovered by the Clock Recovery Module (CRM) from the
PMID data input.
RXDÐOUTb51
These signals are only active when the Alternate PMD Enable (APMDEN) bit of the Alternate PMD
Register (APMDREG) is set to a 1 and are off by default after Reset.
When these two pins are not used they should be left Not Connected (N/C).
RXCÐINa48 I Receive Clock In: Clock inputs to the Player section of the PLAYERa. These inputs must be
synchronized with the RXDÐIN inputs.
RXCÐINb47
These signals are only active when the Alternate PMD Enable (APMDEN) bit of the Alternate PMD
Register (APMDREG) is set to a 1 and are off by default after Reset.
When these two pins are not used, pin 76 should be left Not Connected (N/C) and pin 75 should be
connected directly to ground (ReservedÐ0).
RXDÐINa50 I Receive Data In: Data inputs to the Player section of the PLAYERa. These inputs must be
synchronized with the RXCÐIN inputs.
RXDÐINb49
These signals are only active when the Alternate PMD Enable (APMDEN) bit of the Alternate PMD
Register (APMDREG) is set to a 1 and are off by default after Reset.
When these two pins are not used, pin 78 should be left Not Connected (N/C) and pin 77 should be
connected directly to ground (ReservedÐ0).
PMRDa34 O PMD Request Data: Differential, 100k ECL, 125 Mbps serial data output signals to the PMD
transmitter.
PMRDb33
TXCa31 O Transmit Clock: 125 MHz, 100k ECL compatible differential outputs synchronized to the outgoing
PMRD data.
TXCb30
These signals can be enabled using the Transmit Clock Enable (TXCE) bit in the Clock Generation
Module Register (CGMREG).
When these two pins are not used they should be left Not Connected (N/C).
SDa40 I Signal Detect: Differential, 100k ECL, input signals from the PMD receiver indicating that a signal
is being received by the PMD receiver.
SDb39
96
6.0 Signal Descriptions (Continued)
PHY PORT INTERFACE
The PHY Port Interface consists of I/O signals used to connect the PLAYERadevice to the Media Access Control (MAC)
sublayer or other PLAYERadevice. The DP83256 Device has two PHY Port Interfaces. The AÐIndicate path from one PHY
Port Interface and the BÐRequest path from the second PHY Port Interface. Each path consists of an odd parity bit, a control
bit, and two 4-bit symbols.
Refer to section 3.3, the Configuration Switch, for more information.
Symbol Pin ÝI/O Description
AIP 6 O PHY Port A Indicate Parity: A TTL output signal representing odd parity for the 10-bit wide Port A
Indicate signals (AIP, AIC, and AIDk7:0l).
AIC 7 O PHY Port A Indicate Control: TTL output signal indicating that the two 4-bit symbols (AIDk7:4land
AIDk3:0l) are either control symbols (AICe1) or data symbols (AICe0).
AID7 8 O PHY Port A Indicate Data: TTL output signals representing the first 4-bit data/control symbol.
AID6 9 AID7 is the most significant bit and AID4 is the least significant bit of the first symbol.
AID5 10
AID4 13
AID3 14 O PHY Port A Indicate Data: TTL output signals representing the second 4-bit data/control symbol.
AID2 15 AID3 is the most significant bit and AID0 is the least significant bit of the second symbol.
AID1 16
AID0 17
BRP 70 I PHY Port B Request Parity: A TTL input signal representing odd parity for the 10-bit wide Port A
Request signals (BRP, BRC, and BRDk7:0l).
BRC 69 I PHY Port B Request Control: A TTL input signal indicating that the two 4-bit symbols (BRDk7:4land
BRDk3:0l) are either control symbols (BRCe1) or data symbols (BRCe0).
BRD7 68 I PHY Port B Request Data: TTL input signals representing the first 4-bit data/control symbol.
BRD6 67 BRD7 is the most significant bit and BRD4 is the least significant bit of the first symbol.
BRD5 66
BRD4 63
BRD3 62 I PHY Port B Request Data: TTL input signals representing the second 4-bit data/control symbol.
BRD2 61 BRD3 is the most significant bit and BRD0 is the least significant bit of the second symbol.
BRD1 60
BRD0 59
97
6.0 Signal Descriptions (Continued)
CONTROL BUS INTERFACE
The Control Bus Interface consists of I/O signals used to connect the PLAYERadevice to Station Management (SMT).
The Control Bus is an asynchronous interface between the PLAYERadevice and a general purpose microprocessor or other
controller. It provides access to 64 8-bit internal registers.
In the PLAYERadevice the Control Bus address range has been expanded by 1-bit to 6 bits of address space.
Symbol Pin ÝI/O Description
ECE 73 I Control Enable: An active-low, TTL, input signal which enables the Control Bus port for a read or write
cycle. R/EW, CBAk5:0l, CBP, and CBDk7:0lmust be valid at the time ECE is low.
R/EW72 IRead/EWrite: A TTL input signal which indicates a read Control Bus cycle (R/EWe1), or a write
Control Bus cycle (R/EWe0).
EACK 75 O EAcknowledge: An active low, TTL, open drain output signal which indicates the completion of a read
or write cycle. During a read cycle, CBDk7:0lare valid as long as EACK is low (EACKe0). During a
write cycle, a microprocessor must hold CBDk7:0lvalid until EACK becomes low. Once EACK is low,
it will remain low as long as ECE remains low (ECEe0).
EINT 74 O EInterrupt: An active low, open drain, TTL, output signal indicating that an interrupt condition has
occurred. The Interrupt Condition Register (ICR) should be read in order to find out the source of the
interrupt. Interrupts can be masked through the use of the Interrupt Condition Mask Register (ICMR).
CBA5 83 I Control Bus Address: TTL input signals used to select the address of the register to be read or written.
CBA4 82 CBA5 is the most significant bit (MSB) and CBA0 is the least significant bit (LSB) of the address signals.
CBA3 81
CBA2 80
CBA1 77
CBA0 76
CBP 96 I/O Control Bus Parity: A bidirectional, TTL signal representing odd parity for the Control Bus data
(CBDk7:0l).
During a read cycle, the signal is held valid by the PLAYERadevice as long as EACK is low.
During a write cycle, the signal must be valid when ECE is low, and must be held valid until EACK
becomes low. If incorrect parity is used during a write cycle, the PLAYERadevice will inhibit the write
cycle and set the Control Bus Data Parity Error (CPE) bit in the Interrupt Condition Register (ICR).
CBD7 95 I/O Control Bus Data: Bidirectional, TTL signals containing the data to be read from or written to a register.
CBD6 94 During a read cycle, the signal is held valid by the PLAYERadevice as long as EACK is low.
CBD5 93
During a write cycle, the signal must be valid when ECE is low, and must be held valid until EACK
CBD4 92
becomes low.
CBD3 91
CBD2 90
CBD1 89
CBD0 86
98
6.0 Signal Descriptions (Continued)
CLOCK INTERFACE
The Clock Interface consists of 12.5 MHz and 25 MHz clocks supplied by the PLAYERadevice as well as reference and
feedback inputs.
Symbol Pin ÝI/O Description
LBC1 4 O Local Byte Clock: TTL compatible, 12.5 MHz, 50% duty cycle clock outputs which are phase
locked to a crystal oscillator or reference signal. The PHÐSEL input determines whether the five
LBC2 3
phase outputs are phase offset by 8 ns or 16 ns.
LBC3 2
LBC4 1
LBC5 100
PHÐSEL 22 I Phase Select: TTL compatible input used to select eithera8nsor16nsphase offset between the 5
local byte clocks (LBC’s). The LBC’s are phase offset 8 ns apart when PHÐSEL is at a logic LOW
level and 16 ns apart when at a logic HI level.
FBKÐIN 25 I Feedback Input: TTL compatible input for use as the PLL’s phase comparator feedback input to
close the Phase Locked Loop. This input is intended to be driven from one of the Local Byte Clocks
(LBC’s) from the same PLAYERadevice.
LSC 99 O Local Symbol Clock: TTL compatible 25 MHz output for driving the MACSI or BMAC devices. This
output’s negative phase transition is aligned with the LBC1 output transitions and has a 40% HI and
60% LOW duty cycle.
CLK16 5 O Clock 16/32: TTL compatible clock with a selectable frequency of approximately 15.625 MHz or
31.25 MHz. The frequency can be selected using the Clock Select (CLKSEL) bit of the Mode 2
Register (MODE2).
Note: No glitches appear at the output when switching frequencies.
XTALÐIN 27 I External Crystal Oscillator Input: This input in conjunction with the XTALÐOUT output, is
designed for use of an external crystal oscillator network as the frequency reference for the clock
generation module’s internal VCO. A diagram of the required circuit, which includes only a 12.5 MHz
crystal and 2 loading capacitors, is shown in
Figure 3-19
.
This input is selected when the REFÐSEL input is at a logic LOW level. When not being used, this
input should be tied to ground.
XTALÐOUT 26 O External Crystal Oscillator Output: This output in conjunction with the XTALÐIN input, is designed
for use of an external crystal oscillator network as the frequency reference for the clock generation
module’s internal VCO. A diagram of the required circuit, which includes only a 12.5 MHz crystal and
2 loading capacitors, is shown in
Figure 3-19
.
REFÐIN 24 I Reference Input: TTL compatible input for use as the PLL’s phase comparator reference frequency.
This input is for use in dual attach station or concentrator configurations where there are multiple
PLAYERadevices at a given site requiring synchronization.
This input is selected when the REFÐSEL input is at a logic HI level.
REFÐSEL 23 I Reference Select: TTL compatible input which selects either the crystal oscillator inputs XTALÐIN
and XTALÐOUT or the REFÐIN inputs as the reference frequency inputs for the PLL.
The crystal oscillator inputs are selected when REFÐSEL is at a logic LOW level and the REFÐIN
input is selected as the reference when REFÐSEL is at a logic HI level.
99
6.0 Signal Descriptions (Continued)
MISCELLANEOUS INTERFACE
The Miscellaneous Interface consist of a reset signal and user definable enable signals.
Symbol Pin ÝI/O Description
ERST 71 I Reset: An active low, TTL, input signal which clears all registers. The signal must be kept asserted for a
minimum amount of time. Once the ERST signal is asserted, the PLAYERadevice should be allowed
the specified amount of time to reset internal logic. Note that bit zero of the Mode Register will be set to
zero (i.e. Stop Mode). See section 4.2, Stop Mode of Operation for more information
EP0 41 O User Definable Enable Pin 0: A TTL output signal allowing control of external logic through the Control
Bus Interface. EP0 is asserted/deasserted through Enable Bit 0 (EB0) of the User Definable Register
(UDR). When Enable Bit 0 is set to zero, EP0 is deasserted. When Enable Bit 0 is set to one, EP0 is
asserted.
EP1 43 O User Definable Enable Pin 1: A TTL output signal allowing control of external logic through the Control
Bus Interface. EP1 is asserted/deasserted through Enable Bit 1 (EB1) of the User Definable Register
(UDR). When Enable Bit 1 is set to zero, EP1 is deasserted. When Enable Bit 1 is set to one, EP1 is
asserted.
100
6.0 Signal Descriptions (Continued)
POWER AND GROUND
All power pins should be connected to a single a5V power supply using the recommended filtering. All ground pins should be
connected to a common 0V ground supply. Bypassing and filtering requirements are given in a separate User Information
Document.
Symbol Pin ÝI/O Description
VCCÐANALOG 20 Power: Positive 5V power supply for the Clock Generation Module VCO.
GNDÐANALOG 21 Ground: Power supply return for the Clock Generation Module VCO.
VCCÐCORE 88 Power: Positive 5V power supply for the core PLAYER section logic gates.
GNDÐCORE 87 Ground: Power supply return for the core PLAYER section logic gates.
VCCÐECL 32, Power: Positive 5V power supply for the PLAYERadevice’s ECL logic gates.
37,
45,
56
GNDÐECL 38, Ground: Power supply return for the PLAYERadevice’s ECL logic gates.
46,
55
VCCÐESD 28 Power: Positive 5V power supply for the PLAYERadevice’s ESD protection circuitry.
GNDÐESD 29 Ground: Power supply return for the PLAYERadevice’s ESD protection circuitry.
VCCÐIO 11, Power: Positive 5V power supply for the input/output buffers.
65,
79,
98
GNDÐIO 12, Ground: Power supply return for the input/output buffers.
64,
78,
97
SPECIAL CONNECT PINS
These are pins that have special connection requirements.
No Connect (N/C) pins should not be connected to anything. This means not to power, not to ground, and not to each other.
ReservedÐ0 (RESÐ0) pins must be connected to ground. These pins are not used to supply device power so they do not need
to be filtered or bypassed.
ReservedÐ1 (RESÐ1) pins must be connected to power. These pins are not used to supply device power so they do not need
to be filtered or bypassed.
Symbol Pin ÝI/O Description
N/C 49, 53,
54
No Connect: Pins should not be connected to anything. This means not to power, not to ground, and
not to each other.
RESÐ0 18, 19, Reserved 0: Pins must be connected to ground. These pins are not used to supply device power so
they do not need to be filtered or bypassed.
48, 50,
51, 52,
57, 58,
84
RESÐ185 Reserved 1: Pins must be connected to power. These pins are not used to supply device power so they
do not need to be filtered or bypassed.
101
6.0 Signal Descriptions (Continued)
6.3 DP83257VF SIGNAL DESCRIPTIONS
The pin descriptions for the DP83257VF are divided into five functional interfaces; PMD Interface, PHY Port Interface, Control
Bus Interface, Clock Interface, and Miscellaneous Interface.
For a Pinout Summary List, refer to Table 8-3 and
Figure 8-3
, DP83257VF 160-Pin JEDEC Metric PQFP Pinout.
PMD INTERFACE
The PMD Interface consists of I/O signals used to connect the PLAYERadevice to the Physical Medium Dependant (PMD)
sublayer.
The DP83257 PLAYERadevice actually has two PMD interfaces. The Primary PMD Interface and the Alternate PMD Interface.
The Primary PMD Interface should be used for all PMD implementations that do not require an external scrambler/descrambler
function, clock recovery function, or clock generation function, such as a Fiber Optic or Shielded Twisted Pair (SDDI) PMD. The
second, Alternate PMD Interface can be used to support Unshielded Twisted Pair (UTP) PMDs that require external scrambling,
with no external clock recovery or clock generation functions required.
Section 3.8 describes how the PLAYERacan be connected to the PMD and how the Alternate PMD can be enabled.
Note that when the Alternate PMD Interface is not being used, the pins that make up the interface must be connected in the
specific way described in the following Alternate PMD Interface table.
Primary PMD Interface
Symbol Pin ÝI/O Description
PMIDa62 I PMD Indicate Data: Differential, 100k ECL, 125 Mbps serial data input signals from the PMD Receiver
into the Clock Recovery Module (CRM) of the PLAYERa.
PMIDb61
PMRDa54 O PMD Request Data: Differential, 100k ECL, 125 Mbps serial data output signals to the PMD transmitter.
PMRDb53
SDa60 I Signal Detect: Differential 100k ECL input signals from the PMD receiver indicating that a signal is being
received by the PMD receiver.
SDb59
TEL 74 I PMD Transmitter Enable Level: A TTL input signal to select the PMD transmitter Enable (TXE) signal
level.
TXE 73 O PMD Transmitter Enable: A TTL output signal to enable/disable the PMD transmitter. The output level
of the TXE pin is determined by three parameters: the Transmit Enable (TE) bit in the Mode Register, the
TM2TM0 bits in the Current Transmit State Register, and the input to the TEL pin. The following rules
summarize the output of the TXE pin:
1. If TEe0 and TELeGND, then TXEeVCC
2. If TEe0 and TELeVCC, then TXEeGND
3. If TEe1 and OTM and TELeGND, then TXEeVCC
4. If TEe1 and OTM and TELeVCC, then TXEeGND
5. If TEe1 and not OTM and TELeGND, then TXEeGND
6. If TEe1 and not OTM and TELeVCC, then TXEeVCC
102
6.0 Signal Descriptions (Continued)
Alternate PMD Interface
Symbol Pin ÝI/O Description
PMIDa62 I PMD Indicate Data: Differential, 100k ECL, 125 Mbps serial data input signals from the PMD
Receiver into the Clock Recovery Module (CRM) of the PLAYERa.
PMIDb61
RXCÐOUTa56 O Recovered Clock Out: 125 MHz clock recovered by the Clock Recovery Module (CRM) from the
PMID data input.
RXCÐOUTb55
These signals are only active when the Alternate PMD Enable (APMDEN) bit of the Alternate PMD
Register (APMDREG) is set to a 1 and are off by default after Reset.
When these two pins are not used they should be left Not Connected (N/C).
RXDÐOUTa83 O Recovered Data Out: 125 Mbps data recovered by the Clock Recovery Module (CRM) from the
PMID data input.
RXDÐOUTb82
These signals are only active when the Alternate PMD Enable (APMDEN) bit of the Alternate PMD
Register (APMDREG) is set to a 1 and are off by default after Reset.
When these two pins are not used they should be left Not Connected (N/C).
RXCÐINa76 I Receive Clock In: Clock inputs to the Player section of the PLAYERa. These inputs must be
synchronized with the RXDÐIN inputs.
RXCÐINb75
These signals are only active when the Alternate PMD Enable (APMDEN) bit of the Alternate PMD
Register (APMDREG) is set to a 1 and are off by default after Reset.
When these two pins are not used, pin 76 should be left Not Connected (N/C) and pin 75 should be
connected directly to ground (ReservedÐ0).
RXDÐINa78 I Receive Data In: Data inputs to the Player section of the PLAYERa. These inputs must be
synchronized with the RXCÐIN inputs.
RXDÐINb77
These signals are only active when the Alternate PMD Enable (APMDEN) bit of the Alternate PMD
Register (APMDREG) is set to a 1 and are off by default after Reset.
When these two pins are not used, pin 78 should be left Not Connected (N/C) and pin 77 should be
connected directly to ground (ReservedÐ0).
PMRDa54 O PMD Request Data: Differential, 100k ECL, 125 Mbps serial data output signals to the PMD
transmitter.
PMRDb53
TXCa51 O Transmit Clock: 125 MHz, 100k ECL compatible differential outputs synchronized to the outgoing
PMRD data.
TXCb50
These signals can be enabled using the Transmit Clock Enable (TXCE) bit in the Clock Generation
Module Register (CGMREG).
When these two pins are not used they should be left Not Connected (N/C).
SDa60 I Signal Detect: Differential, 100k ECL, input signals from the PMD receiver indicating that a signal
is being received by the PMD receiver.
SDb59
TEL 74 I PMD Transmitter Enable Level: A TTL input signal to select the PMD transmitter Enable (TXE)
signal level.
TXE 73 O PMD Transmitter Enable: A TTL output signal to enable/disable the PMD transmitter. The output
level of the TXE pin is determined by three parameters: the Transmit Enable (TE) bit in the Mode
Register, the TM2TM0 bits in the Current Transmit State Register, and the input to the TEL pin.
The following rules summarize the output of the TXE pin:
1. If TEe0 and TELeGND, then TXEeVCC
2. If TEe0 and TELeVCC, then TXEeGND
3. If TEe1 and OTM and TELeGND, then TXEeVCC
4. If TEe1 and OTM and TELeVCC, then TXEeGND
5. If TEe1 and not OTM and TELeGND, then TXEeGND
6. If TEe1 and not OTM and TELeVCC, then TXEeVCC
103
6.0 Signal Descriptions (Continued)
PHY PORT INTERFACE
The PHY Port Interface consists of I/O signals used to connect the PLAYERadevice to the Media Access Control (MAC)
sublayer or other PLAYERadevice. The DP83257 Device has two PHY Port Interfaces. The AÐRequest and AÐIndicate paths
from one PHY Port Interface and the BÐRequest and BÐIndicate paths from the second PHY Port Interface. Each path
consists of an odd parity bit, a control bit, and two 4-bit symbols.
Refer to section 3.3, the Configuration Switch, for more information.
Symbol Pin ÝI/O Description
AIP 6 O PHY Port A Indicate Parity: A TTL output signal representing odd parity for the 10-bit wide Port A
Indicate signals (AIP, AIC, and AIDk7:0l).
AIC 8 O PHY Port A Indicate Control: A TTL output signal indicating that the two 4-bit symbols (AIDk7:4land
AIDk3:0l) are either control symbols (AICe1) or data symbols (AICe0).
AID7 10 O PHY Port A Indicate Data: TTL output signals representing the first 4-bit data/control symbol.
AID6 12 AID7 is the most significant bit and AID4 is the least significant bit of the first symbol.
AID5 14
AID4 18
AID3 20 O PHY Port A Indicate Data: TTL output signals representing the second 4-bit data/control symbol.
AID2 22 AID3 is the most significant bit and AID0 is the least significant bit of the second symbol.
AID1 24
AID0 26
ARP 7 I PHY Port A Request Parity: A TTL input signal representing odd parity for the 10-bit wide Port A
Request signals (ARP, ARC, and ARDk7:0l).
ARC 9 I PHY Port A Request Control: A TTL input signal indicating that the two 4-bit symbols
(ARDk7:4land ARDk3:0l) are either control symbols (ARCe1) or data symbols (ARCe0).
ARD7 11 I PHY Port A Request Data: TTL input signals representing the first 4-bit data/control symbol.
ARD6 13 ARD7 is the most significant bit and ARD4 is the least significant bit of the first symbol.
ARD5 15
ARD4 19
ARD3 21 I PHY Port A Request Data: TTL input signals representing the second 4-bit data/control symbol.
ARD2 23 ARD3 is the most significant bit and ARD0 is the least significant bit of the second symbol.
ARD1 25
ARD0 27
BIP 114 O PHY Port B Indicate Parity: A TTL output signal representing odd parity for the 10-bit wide Port A
Indicate signals (BIP, BIC, and BIDk7:0l).
BIC 112 O PHY Port B Indicate Control: A TTL output signal indicating that the two 4-bit symbols (BIDk7:4land
BIDk3:0l) are either control symbols (BICe1) or data symbols (BICe0).
BID7 110 O PHY Port B Indicate Data: TTL output signals representing the first 4-bit data/control symbol.
BID6 108 BID7 is the most significant bit and BID4 is the least significant bit of the first symbol.
BID5 106
BID4 102
BID3 100 O PHY Port B Indicate Data: TTL output signals representing the second 4-bit data/control symbol.
BID2 98 BID3 is the most significant bit and BID0 is the least significant bit of the second symbol.
BID1 96
BID0 94
BRP 115 I PHY Port B Request Parity: A TTL input signal representing odd parity for the 10-bit wide Port A
Request signals (BRP, BRC, and BRDk7:0l).
BRC 113 I PHY Port B Request Control: A TTL input signal indicating that the two 4-bit symbols
(BRDk7:4land BRDk3:0l) are either control symbols (BRCe1) or data symbols (BRCe0).
104
6.0 Signal Descriptions (Continued)
Symbol Pin ÝI/O Description
BRD7 111 I PHY Port B Request Data: TTL input signals representing the first 4-bit data/control symbol.
BRD6 109 BRD7 is the most significant bit and BRD4 is the least significant bit of the first symbol.
BRD5 107
BRD4 103
BRD3 101 I PHY Port B Request Data: TTL input signals representing the second 4-bit data/control symbol.
BRD2 99 BRD3 is the most significant bit and BRD0 is the least significant bit of the second symbol.
BRD1 97
BRD0 95
105
6.0 Signal Descriptions (Continued)
CONTROL BUS INTERFACE
The Control Bus Interface consists of I/O signals used to connect the PLAYERadevice to Station Management (SMT).
The Control Bus is an asynchronous interface between the PLAYERadevice and a general purpose microprocessor or other
controller. It provides access to 64 8-bit internal registers.
In the PLAYERadevice the Control Bus address range has been expanded by 1-bit to 6 bits of address space.
Symbol Pin ÝI/O Description
ECE 118 I Control Enable: An active-low, TTL, input signal which enables the Control Bus port for a read or write
cycle. R/EW, CBAk5:0l, CBP, and CBDk7:0lmust be valid at the time ECE is low.
R/EW 117 I Read/EWrite: A TTL input signal which indicates a read Control Bus cycle (R/EWe1), or a write
Control Bus cycle (R/EWe0).
EACK 120 O EAcknowledge: An active low, TTL, open drain output signal which indicates the completion of a read
or write cycle. During a read cycle, CBDk7:0lare valid as long as EACK is low (EACKe0). During a
write cycle, a microprocessor must hold CBDk7:0lvalid until EACK becomes low. Once EACK is low,
it will remain low as long as ECE remains low (ECEe0).
EINT 119 O EInterrupt: An active low, open drain, TTL, output signal indicating that an interrupt condition has
occurred. The Interrupt Condition Register (ICR) should be read in order to find out the source of the
interrupt. Interrupts can be masked through the use of the Interrupt Condition Mask Register (ICMR).
CBA5 135 I Control Bus Address: TTL input signals used to select the address of the register to be read or written.
CBA4 134 CBA5 is the most significant bit (MSB) and CBA0 is the least significant bit (LSB) of the address signals.
CBA3 133
CBA2 132
CBA1 129
CBA0 128
CBP 148 I/O Control Bus Parity: A bidirectional, TTL signal representing odd parity for the Control Bus data
(CBDl7:0l).
During a read cycle, the signal is held valid by the PLAYERadevice as long as EACK is low.
During a write cycle, the signal must be valid when ECE is low, and must be held valid until EACK
becomes low. If incorrect parity is used during a write cycle, the PLAYERadevice will inhibit the write
cycle and set the Control Bus Data Parity Error (CPE) bit in the Interrupt Condition Register (ICR).
CBD7 147 I/O Control Bus Data: Bidirectional, TTL signals containing the data to be read from or written to a register.
CBD6 146 During a read cycle, the signal is held valid by the PLAYERadevice as long as EACK is low.
CBD5 145
During a write cycle, the signal must be valid when ECE is low, and must be held valid until EACK
CBD4 144
becomes low.
CBD3 143
CBD2 142
CBD1 141
CBD0 138
106
6.0 Signal Descriptions (Continued)
CLOCK INTERFACE
The Clock Interface consists of 12.5 MHz and 25 MHz clocks supplied by the PLAYERadevice as well as reference and
feedback inputs.
Symbol Pin ÝI/O Description
LBC1 4 O Local Byte Clock: TTL compatible, 12.5 MHz, 50% duty cycle clock outputs which are phase
locked to a crystal oscillator or reference signal. The PHÐSEL input determines whether the five
LBC2 3
phase outputs are phase offset by 8 ns or 16 ns.
LBC3 2
LBC4 1
LBC5 160
PHÐSEL 34 I Phase Select: TTL compatible input used to select eithera8nsor16nsphase offset between the 5
local byte clocks (LBC’s). The LBC’s are phase offset 8 ns apart when PHÐSEL is at a logic LOW
level and 16 ns apart when at a logic HI level.
FBKÐIN 37 I Feedback Input: TTL compatible input for use as the PLL’s phase comparator feedback input to
close the Phase Locked Loop. This input is intended to be driven from one of the Local Byte Clocks
(LBC’s) from the same PLAYERadevice.
LSC 159 O Local Symbol Clock: TTL compatible 25 MHz output for driving the MACSI or BMAC devices. This
output’s negative phase transition is aligned with the LBC1 output transitions and has a 40% HI and
60% LOW duty cycle.
CLK16 5 O Clock 16/32: TTL compatible clock with a selectable frequency of approximately 15.625 MHz or
31.25 MHz. The frequency can be selected using the Clock Select (CLKSEL) bit of the Mode 2
Register (MODE2).
Note: No glitches appear at the output when switching frequencies.
XTALÐIN 46 I External Crystal Oscillator Input: This input in conjunction with the XTALÐOUT output, is
designed for use of an external crystal oscillator network as the frequency reference for the clock
generation module’s internal VCO. A diagram of the required circuit, which includes only a 12.5 MHz
crystal and 2 loading capacitors, is shown in
Figure 3-19
.
This input is selected when the REFÐSEL input is at a logic LOW level. When not being used, this
input should be tied to ground.
XTALÐOUT 45 O External Crystal Oscillator Output: This output in conjunction with the XTALÐIN input, is designed
for use of an external crystal oscillator network as the frequency reference for the clock generation
module’s internal VCO. A diagram of the required circuit, which includes only a 12.5 MHz crystal and
2 loading capacitors, is shown in
Figure 3-19
.
REFÐIN 36 I Reference Input: TTL compatible input for use as the PLL’s phase comparator reference frequency.
This input is for use in dual attach station or concentrator configurations where there are multiple
PLAYERadevices at a given site requiring synchronization.
This input is selected when the REFÐSEL input is at a logic HI level.
REFÐSEL 35 I Reference Select: TTL compatible input which selects either the crystal oscillator inputs XTALÐIN
and XTALÐOUT or the REFÐIN inputs as the reference frequency inputs for the PLL.
The crystal oscillator inputs are selected when REFÐSEL is at a logic LOW level and the REFÐIN
input is selected as the reference when REFÐSEL is at a logic HI level.
LPFLTR 49 O Loop Filter: This is a diagnostic output that allows monitoring of the clock generation module’s filter
node. This output is disabled by default and does not need to be connected to any external device. It
can be enabled using the FLTREN bit of the Clock generation module register (CGMREG).
Note: In normal operation this pin should be disabled.
107
6.0 Signal Descriptions (Continued)
MISCELLANEOUS INTERFACE
The Miscellaneous Interface consist of a reset signal, user definable sense signals, and user definable enable signals.
Symbol Pin ÝI/O Description
ERST 116 I Reset: An active low, TTL, input signal which clears all registers. The signal must be kept asserted for a
minimum amount of time. Once the ERST signal is asserted, the PLAYERadevice should be allowed
the specified amount of time to reset internal logic. Note that bit zero of the Mode Register will be set to
zero (i.e. Stop Mode). See section 4.2, Stop Mode of Operation for more information
SP0 63 I User Definable Sense Pin 0: A TTL input signal from a user defined source. Sense Bit 0 (SB0) of the
User Definable Register (UDR) will be set to one if the signal is asserted for a minimum of 160 ns. Once
the asserted signal is latched, Sense Bit 0 can only be cleared through the Control Bus Interface, even if
the signal is deasserted. This ensures that the Control Bus Interface will record the source of events
which can cause interrupts.
SP1 65 I User Definable Sense Pin 1: A TTL input signal from a user defined source. Sense Bit 1 (SB1) of the
User Definable Register (UDR) will be set to one if the signal is asserted for a minimum of 160 ns. Once
the asserted signal is latched, Sense Bit 1 can only be cleared through the Control Bus Interface, even if
the signal is deasserted. This ensures that the Control Bus Interface will record the source of events
which can cause interrupts.
SP2 67 I User Definable Sense Pin 2: A TTL input signal from a user defined source. Sense Bit 2 (SB2) of the
User Definable Register (UDR) will be set to one if the signal is asserted for a minimum of 160 ns. Once
the asserted signal is latched, Sense Bit 2 can only be cleared through the Control Bus Interface, even if
the signal is deasserted. This ensures that the Control Bus Interface will record the source of events
which can cause interrupts.
EP0 64 O User Definable Enable Pin 0: A TTL output signal allowing control of external logic through the Control
Bus Interface. EP0 is asserted/deasserted through Enable Bit 0 (EB0) of the User Definable Register
(UDR). When Enable Bit 0 is set to zero, EP0 is deasserted. When Enable Bit 0 is set to one, EP0 is
asserted.
EP1 66 O User Definable Enable Pin 1: A TTL output signal allowing control of external logic through the Control
Bus Interface. EP1 is asserted/deasserted through Enable Bit 1 (EB1) of the User Definable Register
(UDR). When Enable Bit 1 is set to zero, EP1 is deasserted. When Enable Bit 1 is set to one, EP1 is
asserted.
EP2 68 O User Definable Enable Pin 2: A TTL output signal allowing control of external logic through the Control
Bus Interface. EP2 is asserted/deasserted through Enable Bit 2 (EB2) of the User Definable Register
(UDR). When Enable Bit 2 is set to zero, EP2 is deasserted. When Enable Bit 2 is set to one, EP2 is
asserted.
CS 69 I Cascade Start: A TTL input signal used to synchronize cascaded PLAYERadevices in point-to-point
applications.
The signal is asserted when all of the cascaded PLAYERadevices have the Cascade Mode (CM) bit of
the Mode Register (MR) set to one, and all of the Cascade Ready (CR) pins of the cascaded PLAYERa
devices have been released.
When Cascade Mode is not being used, this input should be tied to Ground.
For further information, refer to section 4.4, Cascade Mode of Operation.
CR 70 O Cascade Ready: An Open Drain output signal used to synchronize cascaded PLAYERadevices in
point-to-point applications.
The signal is released (i.e. an Open Drain line is released) when all the cascaded PLAYERadevices
have the Cascade Mode (CM) bit of the Mode Register (MR) is set to one and a JK symbol pair has been
received.
When Cascade Mode is not being used, this input should be left Not Connected (N/C).
For further information, refer to section 4.4, Cascade Mode of Operation.
108
6.0 Signal Descriptions (Continued)
POWER AND GROUND
All power pins should be connected to a single a5V power supply using the recommended filtering. All ground pins should be
connected to a common 0V ground supply. Bypassing and filtering requirements are given in a separate User Information
Document.
Symbol Pin ÝI/O Description
VCCÐANALOG 32 Power: Positive 5V power supply for the PLAYERadevice’s CGM VCO.
GNDÐANALOG 33 Ground: Power supply return for the PLAYERadevice’s CGM VCO.
VCCÐCORE 140 Power: Positive 5V power supply for the core PLAYER logic gates.
GNDÐCORE 139 Ground: Power supply return for the core PLAYER logic gates.
VCCÐECL 52, 57, Power: Positive 5V power supply for the PLAYERadevice’s ECL logic gates.
71, 89
GNDÐECL 58, 72, Ground: Power supply return for the PLAYERadevice’s ECL logic gates.
88
VCCÐESD 47 Power: Positive 5V power supply for the PLAYERadevice’s ESD protection circuitry.
GNDÐESD 48 Ground: Power supply return for the PLAYERadevice’s ESD protection circuitry.
VCCÐIO 16, 105, Power: Positive 5V power supply for the input/output buffers.
131, 158
GNDÐIO 17, 104, Ground: Power supply return for the input/output buffers.
130, 157
SPECIAL CONNECT PINS
These are pins that have special connection requirements.
No Connect (N/C) pins should not be connected to anything. This means not to power, not to ground, and not to each other.
ReservedÐ0 (RESÐ0) pins must be connected to ground. These pins are not used to supply device power so they do not need
to be filtered or bypassed.
ReservedÐ1 (RESÐ1) pins must be connected to power. These pins are not used to supply device power so they do not need
to be filtered or bypassed.
Symbol Pin ÝI/O Description
N/C 38, 39, No Connect: Pins should not be connected to anything. This means not to power, not
to ground, and not to each other.
40, 41, 42, 43, 44,
79,
80, 81, 87,
121, 122, 123, 124, 125,
126, 127,
149,
150, 151, 152, 153,154,
155, 156
RESÐ0 28, 29, Reserved 0: Pins must be connected to ground. These pins are not used to supply
device power so they do not need to be filtered or bypassed.
30, 31,
84, 85, 86,
90, 91, 92, 93,
136
RESÐ1 137 Reserved 1: Pins must be connected to power. These pins are not used to supply
device power so they do not need to be filtered or bypassed.
109
7.0 Electrical Characteristics
7.1 ABSOLUTE MAXIMUM RATINGS
Symbol Parameter Conditions Min Typ Max Units
VCC Supply Voltage b0.5 7.0 V
DCIN Input Voltage b0.5 VCC a0.5 V
DCOUT Output Voltage b0.5 VCC a0.5 V
VCCÐESD to other VCC
Maximum Voltage 0.3 V
Differential
Storage Temperature b65 150 §C
ECL Signal Output Current b50 mA
ESD Protection 2000 V
7.2 RECOMMENDED OPERATING CONDITIONS
Symbol Parameter Conditions Min Typ Max Units
VCC Supply Voltage 4.75 5.25 V
TAOperating Temperature 0 70 §C
FREF Reference Input Frequency 12.550 ppm 12.5 12.5 a50 ppm MHz
7.3 RECOMMENDED EXTERNAL COMPONENTS
Symbol Parameter Conditions Min Typ Max Units
XTAL Crystal Specifications
Center Frequency 12.5 MHz
Frequency Calibration b10 10 ppm
Frequency Stability Over Temperature b10 10 ppm
Aging Less Than b5 5 ppm
Recommended Power Supply Bypassing Capacitor Value 0.1 mF
Note: Capacitors should be placed between each supply pair as close to the
device as possible.
7.4 DC ELECTRICAL CHARACTERISTICS
The DC characteristics are specified over the Recommended Operating Conditions, unless otherwise specified.
DC Electrical Characteristics for All TTL-Compatible Inputs
The following signals are covered: PHY Port Request Signals (ARD, ARC, ARP, BRD, BRC, BRP), Phase Select (PHÐSEL),
Reference Select (REFÐSEL), Sense Pins (SP), Cascade Start (CS), PMD Transmitter Enable Level (TEL), Device Reset
(ERST), and Control Bus Interface Inputs (R/EW, ECE, CBA).
Symbol Parameter Conditions Min Typ Max Units
VIH Input High Voltage 2.0 V
VIL Input Low Voltage 0.8 V
VIC Input Clamp Voltage IIN eb
18 mA b1.5 V
IIL Input Low Current VIN eGND b10 mA
IIH Input High Current VIN eVCC a10 mA
110
7.0 Electrical Characteristics (Continued)
DC Electrical Characteristics for All TTL-Compatible Non-TRI-STATE Outputs
The following signals are covered: Clock 16/32 (CLK16), Enable Pins (EP), and PMD Transmitter Enable (TXE).
Symbol Parameter Conditions Min Typ Max Units
VOH Output High Voltage IOH eb
2mA V
CC b0.5 V
VOL Output Low Voltage IOL e4 mA 0.5 V
DC Electrical Characteristics for All TTL-Compatible TRI-STATE Outputs
The following signals are covered: PHY Port Indicate Signals (AID, AIC, AIP, BID, BIC, BIP).
Symbol Parameter Conditions Min Typ Max Units
VOH Output High Voltage IOH eb
2mA V
CC b0.5 V
VOL Output Low Voltage IOL e4 mA 0.5 V
IOZ3 TRI-STATE Leakage VOUT eVCC 60 mA
(Note 1)
IOZ4 TRI-STATE Leakage VOUT eVGND b500 mA
(Note 1)
Note 1: Output buffer has a p-channel pullup device.
DC Electrical Characteristics for All TTL-Compatible Input/Outputs
The following signals are covered: Control Bus Interface I/O (CBD, CBP).
Symbol Parameter Conditions Min Typ Max Units
VIH Input High Voltage 2.0 V
VIL Input Low Voltage 0.8 V
VIC Input Clamp Voltage IIN eb
18 mA b1.5 V
IIL Input Low Current VIN eGND b10 mA
IIH Input High Current VIN eVCC a10 mA
VOH Output High Voltage IOH eb
2mA V
CC b0.5 V
VOL Output Low Voltage IOL e4 mA 0.5 V
IOZ1 TRI-STATE Leakage VOUT eVCC 10 mA
IOZ2 TRI-STATE Leakage VOUT eVGND b10 mA
111
7.0 Electrical Characteristics (Continued)
DC Electrical Characteristics for All FDDI Clock Outputs
The following signals are covered: Local Byte Clocks (LBC1LBC5), and Local Symbol Clock (LSC).
These outputs are designed to drive capacitive loads from 20 pF to 60 pF.
Symbol Parameter Conditions Min Typ Max Units
VOH Output High Voltage IOH eb
400 mAV
CC b2V
V
OL Output Low Voltage IOL e8 mA 0.5 V
DC Electrical Characteristics for All Clock Reference Inputs
The following signals are covered: Reference In (REFÐIN) and Feedback In (FBKÐIN).
Symbol Parameter Conditions Min Typ Max Units
VIH Input High Voltage 2.0 V
VIL Input Low Voltage 0.8 V
VIC Input Clamp Voltage IIN eb
18 mA b1.5 V
IIL Input Low Current VIN eGND b10 mA
IIH Input High Current VIN eVCC a10 mA
DC Electrical Characteristics for Crystal Inputs and Outputs
The following signals are covered: Crystal In (XTALÐIN) and Crystal Out (XTALÐOUT).
Symbol Parameter Conditions Min Typ Max Units
IOL Output Low Current VOUT e1V 4 mA
(Note A)
IOH Output High Current VOUT eVCC b1V b4mA
(Note A)
Small Signal Gain XTALÐIN e100 mV 45
Centered about VTH
(Note A)
VTH Input Threshold (Note A) 2.2 V
Voltage
XTALÐIN to (Note A) 7.0 ns
XTALÐOUT Delay
Output Impedance (Note A) 270 X
Internal Resistor (Note A) 10 kX
Variation
Note A: This parameter is presented as a typical value to provide enough information to design an appropriate crystal network.
DC Electrical Characteristics for All Open Drain Outputs
The following signals are covered: Interrupt (EINT), Acknowledge (EACK), and Cascade Ready (CR).
Symbol Parameter Conditions Min Typ Max Units
VOL Output Low Voltage IOL e8 mA 0.5 V
IOZ TRI-STATE Leakage VOUT eVCC 10 mA
112
7.0 Electrical Characteristics (Continued)
DC Electrical Characteristics for All 100K ECL Compatible Inputs
The following signals are covered: PMD Indicate Data (PMID), Receive Clock In (RXCÐIN), Receive Data In (RXDÐIN), and
Signal Detect (SD).
Symbol Parameter Conditions Min Typ Max Units
VDIFF Input Voltage Differential (Note 1) 150 mV
VCM Common Mode Voltage VDIFF e300 mV VCC b2.0 VCC b0.5 V
(Notes 1, 2)
IIN Input Current VIN eVCC or GND b200 200 mA
Note 1: Both inputs of each differential pair are tested together. These specifications guarantee that the inputs are compatible with standard 100K ECL voltage
level outputs.
Note 2: VCM is measured from the crossover point of the 300 mV differential test input.
DC Electrical Characteristics for 100K ECL Compatible Outputs
The following signals are covered: PMD Request Data (PMRD) and Transmit Clock (TXC).
Symbol Parameter Conditions Min Typ Max Units
VOH Output High Voltage VIL eVCC b1.810 VCC b1.025 VCC b0.880 V
VOL Output Low Voltage VIH eVCC b0.880 VCC b1.810 VCC b1.620 V
DC Electrical Characteristics for Alternate PMD ECL Outputs
The following signals are covered: Receive Clock Out (RXCÐOUT) and Receive Data Out (RXDÐOUT).
Symbol Parameter Conditions Min Typ Max Units
VOH Output High Voltage VIL eVCC b1.810 VCC b1.155 VCC b0.880 V
VOL Output Low Voltage VIH eVCC b0.880 VCC b1.810 VCC b1.550 V
(Note 3)
Note 3: It is recommended that RXCÐOUTaand RXCÐOUTbalways be used together as a differential pair. It is recommended that RXDÐOUTaand
RXDÐOUTbalways be used together as a differential pair.
Supply Current Electrical Characteristics
Symbol Parameter Conditions Min Typ Max Units
ICC Total Supply LBC1 e12.5 MHz 350*mA
ECLÐICC ECL Supply Current LBC1 e12.5 MHz 200*mA
ANALOGÐICC ANALOG Supply Current LBC1 e12.5 MHz 20*mA
*Note: The PLAYERadevice has multiple pairs of differential ECL outputs that need to be terminated. The additional current needed for this termination is not
included in the PLAYERa’s total supply current, but can be calculated as follows:
VOHÐmax eVCC b0.88V
VOLÐmax eVCC b1.62V
Since the outputs are differential, the average output level is VCC b1.25V. The test load per output is 50Xat VCC b2V, therefore the external load current
through the 50Xresistor is:
ILOAD e[(VCC b1.25) b(VCC b2)]/50
e0.015A
e15 mA
As a result, the termination for each pair of active ECL outputs typically consumes 30 mA, time averaged.
113
7.0 Electrical Characteristics (Continued)
7.5 AC ELECTRICAL CHARACTERISTICS
The AC Electrical characteristics are specified over the Recommended Operating Conditions, unless otherwise specified.
AC Characteristics for the Control Bus Interface
The following signals are covered: Control Bus Interface (R/EW, ECE, EINT, EACK, CBA, CBD, and CBP).
Symbol Descriptions Min Max Units
T1 CE Setup to LBC 15 ns
T2 LBC Period 80 ns
T3 LBC1 to ACK Low 45 ns
T4 CE Low to ACK Low 290 540 ns
T5 LBC1 Low to CBD(7 0) and CBP Valid 60 ns
T6 LBC1 to CBD(7 0) and CBP Active 5 ns
T7 CE Low to CBD(7 0) and CBP Active 225 475 ns
T8 CE Low to CBD(7 0) and CBP Valid 265 515 ns
T9 LBC Pulse Width High 35 45 ns
T10 LBC Pulse Width Low 35 45 ns
T11 CE High to ACK High 45 ns
T12 R/W, CBA(50), CBD(7 0) and CBP Setup to CE Low 5 ns
T13 CE High to R/W, CBA(50), CBD(7 0) and CBP Hold Time 0 ns
T14 R/W, CBA(50), CBD(7 0) and CBP to LBC1 Setup Time 20 ns
T15 ACK Low to CE High Lead Time 0 ns
T16 CE Minimum Pulse Width High 20 ns
T17 CE High to CBD(70) and CBP TRI-STATE 55 ns
T18 ACK High to CE Low 0 ns
T19 CBD(70) Valid to ACK Low Setup 20 ns
T20a LBC1 to R/W Hold Time 10 ns
T20b LBC1 to CBA Hold Time 10 ns
T20c LBC1 to CBD and CBP Hold Time 20 ns
T21 LBC1 to INT Low 55 ns
T22 LBC1 to EP Change 5 25 ns
Asynchronous Definitions
T4 (min) T1 a(3 *T2) aT3
T4 (max) T1 a(6 *T2) aT3
T7 (min) T1 a(2 *T2) aT6
T7 (max) T1 a(5 *T2) aT6
T8 (min) T1 a(2 *T2) aT9 aT5
T8 (max) T1 a(5 *T2) aT9 aT5
Note: Min/Max numbers are based on T2 e80 ns and T9 eT10 e40 ns.
114
7.0 Electrical Characteristics (Continued)
TL/F/11708 29
FIGURE 7-1. Asynchronous Control Bus Write Cycle Timing
TL/F/11708 30
FIGURE 7-2. Asynchronous Control Bus Read Cycle Timing
115
7.0 Electrical Characteristics (Continued)
TL/F/11708 31
FIGURE 7-3. Control Bus Synchronous Writes
TL/F/11708 32
FIGURE 7-4. Control Bus Synchronous Reads
TL/F/11708 50
FIGURE 7-5. Control Bus Interrupt Timing
116
7.0 Electrical Characteristics (Continued)
AC Characteristics for the Clock Interface Signals (Timing and Relationships)
Symbol Parameter Conditions Min Typ Max Units
TPhase1 LBC1LBC2 Timing PHÐSEL eLOW 5.0 8 11.0 ns
TPhase2 LBC1LBC3 Timing PHÐSEL eLOW 13.0 16 19.0 ns
TPhase3 LBC1LBC4 Timing PHÐSEL eLOW 21.0 24 27.0 ns
TPhase4 LBC1LBC5 Timing PHÐSEL eLOW 29.0 32 35.0 ns
TPhase1 LBC1LBC2 Timing PHÐSEL eHIGH 45.0 48 51.0 ns
TPhase2 LBC1LBC3 Timing PHÐSEL eHIGH 13.0 16 19.0 ns
TPhase3 LBC1LBC4 Timing PHÐSEL eHIGH 61.0 64 67.0 ns
TPhase4 LBC1LBC5 Timing PHÐSEL eHIGH 29.0 32 35.0 ns
TPhase5 LBC5 Rising- PHÐSEL eLOW or 5.0 8 12.0 ns
LBC1 Falling Timing PHÐSEL eHIGH
T23 LSC Falling to LBC1 (Note 1) b3a6ns
T24 REFÐIN to FBKÐIN In Lock b2a2ns
Note 1: LSC loading must always be less than or equal to LBC1 loading.
TL/F/11708 33
FIGURE 7-6. Clock Signal Relationships
117
7.0 Electrical Characteristics (Continued)
TL/F/11708 51
FIGURE 7-7. Typical Clock Signal Relationships Based on Phase Select (PHÐSEL) Setting
118
7.0 Electrical Characteristics (Continued)
AC Characteristics for the Clock Interface Signals (Periods and Pulse Widths)
Symbol Parameter Conditions Min Typ Max Units
T2 LBC Period 80 ns
T9 LBC Pulse Width High 35 45 ns
T10 LBC Pulse Width Low 35 45 ns
T25 LSC Pulse Width High 12 19 ns
T26 LSC Pulse Width Low 21 28 ns
T27 CLK16 Period MODE2.CLKSEL e064 ns
T28 CLK16 Pulse Width MODE2.CLKSEL e027 32 37 ns
(Note 1)
T27 CLK16 Period MODE2.CLKSEL e132 ns
T28 CLK16 Pulse Width MODE2.CLKSEL e111 16 21 ns
(Note 1)
T29 REFÐIN Pulse Width High 35 45 ns
Note 1: This parameter is not tested, but is assured by correlation with characterization data.
TL/F/11708 34
FIGURE 7-8. Clock Pulse Widths
AC Characteristics for Port A Interface and Port B Interface
The following signals are covered: PHY Port A (AID, AIP, AIC, ARD, ARP, ARC) and PHY Port B (BID, BIP, BIC, BRD, BRP,
BRC).
Symbol Parameter Conditions Min Typ Max Units
T30 LBC1 to Indicate Data Changes from 70 ns
TRI-STATE to Valid Data
T31 LBC1 to Indicate Data Changes from 70 ns
Active to TRI-STATE
T32 LBC1 to Indicate Data Sustain 9 ns
T33 LBC1 to Valid Indicate Data 45 ns
T34 Request Data to LBC1 Setup Time 15 ns
T35 Request Data to LBC1 Hold Time 3 ns
TL/F/11708 35
FIGURE 7-9. PHY Port Interface Timing
119
7.0 Electrical Characteristics (Continued)
AC Characteristics for the PMD Interface
The following signals are covered: PMD Indicate Data (PMID), Signal Detect (SD), and PMD Request Data (PMRD).
Symbol Parameter Conditions Min Typ Max Units
T36 PMIDgto PMRDgLatency Looped Back through 5 LBC
Configuration Switch. Cycles
LBC1 e12.5 MHz
In Lock
(Note 1)
T37 SD Minimum Pulse Width 120 ns
T38 PMRD Rise Time (Note 2) 1.5 ns
T39 PMRD Fall Time (Note 2) 1.5 ns
Note 1: This only applies when the Alternate PMD Interface is disabled, APMDREG.APMDEN e0.
Note 2: This parameter is not tested, but is assured by correlation with characterization data.
TL/F/11708 36
FIGURE 7-10. Primary PMD Timing Diagrams
120
7.0 Electrical Characteristics (Continued)
AC Characteristics for the Alternate PMD Interface
The following input signals are covered: PMD Indicate Data (PMID), Signal Detect (SD), Receive Data In (RXDÐIN), Receive
Clock In (RXCÐIN).
The following output signals are covered: PMD Request Data (PMRD), Transmit Clock (TXC), Recovered Data Out
(RXDÐOUT), Recovered Clock Out (RXCÐOUT).
Note: The Alternate PMD Interface is only available on the 160 pin DP83257 PLAYERaDevice and the 100 pin DP83256-AP Device. The Transmit Clock is
enabled by the CGMREG.TXCE bit. The rest of the Alternate PMD Interface is enabled by the APMDREG.APMDEN bit.
Symbol Parameter Conditions Min Typ Max Units
T40 RXCÐOUTato RXDÐOUTgChange Time 1.0 5.0 ns
T41 PMIDgto RXDÐOUT Latency In Lock 16 ns
T42 RXDÐINgto RXCÐINaSetup Time 4.0 ns
T43 RXDÐINgto RXCÐINaHold Time 0.5 ns
T44 TXCato PMRDgChange Time 4.0 7.0 ns
T42 SD Minimum Pulse Width 120 ns
T45 RXCÐOUTgPulse Width High (Note 1) 3.5 4.5 ns
T46 RXCÐOUTgRise Time (Note 1) 1.5 ns
T47 RXCÐOUTgFall Time (Note 1) 1.5 ns
T48 RXDÐOUTgRise Time (Note 1) 1.5 ns
T49 RXDÐOUTgFall Time (Note 1) 1.5 ns
T50 TXCgPulse Width High (Note 1) 3.5 4.5 ns
T51 TXCgRise Time (Note 1) 1.5 ns
T52 TXCgFall Time (Note 1) 1.5 ns
T38 PMRD Rise Time (Note 1) 1.5 ns
T39 PMRD Fall Time (Note 1) 1.5 ns
Note 1: This parameter is not tested, but is assured by correlation with characterization data.
TL/F/11708 52
FIGURE 7-11. ECL Rise and Fall Times
121
7.0 Electrical Characteristics (Continued)
TL/F/11708 53
FIGURE 7-12. Alternate PMD Timing Diagrams
122
7.0 Electrical Characteristics (Continued)
AC Characteristics for the PMD Interface Inputs (ANSI Specifications)
The following input signals are covered: PMD Indicate Data (PMID), Receive Data In (RXDÐIN), Receive Clock In (RXCÐIN).
Note: The Alternate PMD Interface is only available on the 160 pin DP83257 PLAYERaDevice and the 100 pin DP83256-AP Device. The Transmit Clock is
enabled by the CGMREG.TXCE bit. The rest of the Alternate PMD Interface is enabled by the APMDREG.APMDEN bit.
All comments in square brackets are section references to the ANSI documents where these specifications can be found.
Symbol Parameter Conditions Min Typ Max Units
T53 CRM Window Recognition Region [PMD E.2]b33ns
(PMID Inputs)
T54 PMID Receive Clock Tolerance [PHY 5.2.4]b100 100 ppm
(Lock Acquisition Range)
T55 Receive Clock Acquisition Time From 1st Data 100 ms
and SD Active
[PHY 5.2.6]
T56 Receive Clock Acquisition Time From Line State 15 ms
Change
[PHY 5.2.6]
TL/F/11708 54
TL/F/11708 55
FIGURE 7-13. Alternate PMD Input Timing DiagramsÐANSI Specifications
123
7.0 Electrical Characteristics (Continued)
AC Characteristics for the PMD Interface Outputs (ANSI Specifications)
The following output signals are covered: PMD Request Data (PMRD), Transmit Clock (TXC), Recovered Data Out
(RXDÐOUT), Recovered Clock Out (RXCÐOUT).
Note: The Alternate PMD Interface is only available on the 160 pin DP83257 PLAYERaDevice and the 100 pin DP83256-AP Device. The Transmit Clock is
enabled by the CGMREG.TXCE bit. The rest of the Alternate PMD Interface is enabled by the APMDREG.APMDEN bit.
Comments in square brackets are section references to the ANSI documents where these specifications can be found.
Symbol Parameter Conditions Min Typ Max Units
T57 PMRD Total Transmit Jitter (Note 1) 0.72 ns p-p
[Duty Cycle Distortion (DCD)a[PMD 8.1]
Data Dependent Jitter (DDJ)a
Random Jitter (RJ)]
T58 Total Recovered Clock (RXCÐOUT) Jitter (Note 1) 2.5 ns p-p
[Static Alignment Error Accuracy (SAE)a[PMD E.2]
Clock Data Dependent Jitter (CÐDDJ)a
Random Jitter (CÐRJ)]
Note 1: This parameter is not tested, but is assured through characterization data and periodic testing of sample units.
124
7.0 Electrical Characteristics (Continued)
AC Characteristics for User Definable Pins
The following signals are covered: Sense Pins (SP).
For Enable Pins (EP) timing see AC Characteristics for the Control Bus Interface.
Symbol Parameter Conditions Min Typ Max Units
T59 SP Minimum Pulse Width 120 ns
TL/F/11708 56
FIGURE 7-14. SP Minimum Pulse Width
AC Characteristics for Miscellaneous Interface
The following signal is covered: Reset (ERST).
Symbol Parameter Conditions Min Typ Max Units
T60 Minimum Reset (ERST) Pulse Width 300 ns
T61 Maximum Power Up Reset Cycle Duration (Notes 1, 2) 10 ms
T62 Maximum Hardware Reset (ERST) Cycle Duration 0.5 ms
Note 1: This parameter is not tested, but is assured by correlation with characterization data.
Note 2: User must wait this long before trying to access the device after power up. It is recommended that a Hardware Reset be used sometime after the Power Up
Reset cycle is complete to insure proper device reset.
TL/F/11708 57
FIGURE 7-15. Reset Timing
125
7.0 Electrical Characteristics (Continued)
AC TEST CIRCUITS
TL/F/11708 37
Note: S1is closed for TPZL and TPLZ
S2is closed for TPZH and TPHZ
S1and S2are open otherwise
FIGURE 7-16. Switching Test Circuit for All TRI-STATE Output Signals
TL/F/11708 38
FIGURE 7-17. Switching Test Circuit for All TTL Output Signals
TL/F/11708 39
FIGURE 7-18. Switching Test Circuit for All Open Drain Output Signals (INT, ACK, and CR)
TL/F/11708 40
FIGURE 7-19. Switching Test Circuit for All ECL Input and Output Signals
126
7.0 Electrical Characteristics (Continued)
TEST WAVEFORMS
TL/F/11708 41
FIGURE 7-20. ECL Output Test Waveform
TL/F/11708 42
Note: All CMOS Inputs and outputs are TTL compatible.
FIGURE 7-21. TTL Output Test Waveform
TL/F/11708 43
FIGURE 7-22. TRI-STATE Output Test Waveform
127
8.0 Connection Diagrams
8.1 DP83256VF CONNECTION DIAGRAM
For a Pinout Summary List, refer to Table 8-1.
TL/F/11708 44
FIGURE 8-1. DP83256VF 100-Pin JEDEC Metric PQFP Pinout
128
8.0 Connection Diagrams (Continued)
TABLE 8-1. DP83256 100-Pin PQFP Pinout Summary
Pin No. Signal Name Symbol I/O Pin Type
1 Local Byte Clock 4 LBC4 O TTL
2 Local Byte Clock 3 LBC3 O TTL
3 Local Byte Clock 2 LBC2 O TTL
4 Local Byte Clock 1 LBC1 O TTL
5 Clock 16/32 CLK16 O TTL
6 PHY Port A Indicate Parity AIP O TTL
7 PHY Port A Indicate Control AIC O TTL
8 PHY Port A Indicate Datak7lAID7 O TTL
9 PHY Port A Indicate Datak6lAID6 O TTL
10 PHY Port A Indicate Datak5lAID5 O TTL
11 I/O Power VCCÐIO a5V
12 I/O Ground GNDÐIO a0V
13 PHY Port A Indicate Datak4lAID4 O TTL
14 PHY Port A Indicate Datak3lAID3 O TTL
15 PHY Port A Indicate Datak2lAID2 O TTL
16 PHY Port A Indicate Datak1lAID1 O TTL
17 PHY Port A Indicate Datak0lAID0 O TTL
18 ReservedÐ0 RESÐ0a0V
19 ReservedÐ0 RESÐ0a0V
20 ANALOG Power VCCÐANALOG a5V
21 ANALOG Ground GNDÐANALOG a0V
22 Phase Select PHÐSEL I TTL
23 Reference Select REFÐSEL I TTL
24 Reference Input REFÐIN I TTL
25 Feedback Input FBKÐIN I TTL
26 Crystal Output XTALÐOUT O
27 Crystal Input XTALÐIN I
28 ESD Power VCCÐESD a5V
29 ESD Ground GNDÐESD a0V
30 Loop Filter LPFLTR O
31 ECL Power VCCÐECL a5V
32 PMD Request Data bPMRDbO ECL
33 PMD Request Data aPMRDaO ECL
34 ECL Power VCCÐECL a5V
35 ECL Ground GNDÐECL a0V
36 Signal Detect bSDbI ECL
37 Signal Detect aSDaI ECL
38 PMD Indicate Data bPMIDbI ECL
129
8.0 Connection Diagrams (Continued)
TABLE 8-1. DP83256 100-Pin PQFP Pinout Summary (Continued)
Pin No. Signal Name Symbol I/O Pin Type
39 PMD Indicate Data aPMIDaI ECL
40 Sense Pin 0 SP0 I TTL
41 Enable Pin 0 EP0 O TTL
42 Sense Pin 1 SP1 I TTL
43 Enable Pin 1 EP1 O TTL
44 ECL Power VCCÐECL a5V
45 ECL Ground GNDÐECL a0V
46 PMD Transmitter Enable TXE O TTL
47 PMD Transmitter Enable Level TEL I TTL
48 ReservedÐ0 RESÐ0a0V
49 No Connect N/C
50 ReservedÐ0 RESÐ0a0V
51 ReservedÐ0 RESÐ0a0V
52 ReservedÐ0 RESÐ0a0V
53 ReservedÐ0 RESÐ0a0V
54 No Connect N/C
55 ECL Ground GNDÐECL a0V
56 ECL Power VCCÐECL a5V
57 ReservedÐ0 RESÐ0a0V
58 ReservedÐ0 RESÐ0a0V
59 PHY Port B Request Datak0lBRD0 I TTL
60 PHY Port B Request Datak1lBRD1 I TTL
61 PHY Port B Request Datak2lBRD2 I TTL
62 PHY Port B Request Datak3lBRD3 I TTL
63 PHY Port B Request Datak4lBRD4 I TTL
64 I/O Ground GNDÐIO a0V
65 I/O Power VCCÐIO a5V
66 PHY Port B Request Datak5lBRD5 I TTL
67 PHY Port B Request Datak6lBRD6 I TTL
68 PHY Port B Request Datak7lBRD7 I TTL
69 PHY Port B Request Control BRC I TTL
70 PHY Port B Request Parity BRP O TTL
71 EDevice Reset ERST I TTL
72 Read/EWrite R/EW I TTL
73 Chip Enable ECE I TTL
74 EInterrupt EINT O Open Drain
75 EAcknowledge EACK O Open Drain
76 Control Bus Addressk0lCBA0 I TTL
130
8.0 Connection Diagrams (Continued)
TABLE 8-1. DP83256 100-Pin PQFP Pinout Summary (Continued)
Pin No. Signal Name Symbol I/O Pin Type
77 Control Bus Addressk1lCBA1 I TTL
78 I/O Logic Ground GNDÐIO a0V
79 I/O Logic Power VCCÐIO a5V
80 Control Bus Addressk2lCBA2 I TTL
81 Control Bus Addressk3lCBA3 I TTL
82 Control Bus Addressk4lCBA4 I TTL
83 Control Bus Addressk5lCBA5 I TTL
84 ReservedÐ0 RESÐ0a0V
85 ReservedÐ1 RESÐ1a5V
86 Control Bus Datak0lCBD0 I/O TTL
87 Core Ground GNDÐCORE a0V
88 Core Power VCCÐCORE a5V
89 Control Bus Datak1lCBD1 I/O TTL
90 Control Bus Datak2lCBD2 I/O TTL
91 Control Bus Datak3lCBD3 I/O TTL
92 Control Bus Datak4lCBD4 I/O TTL
93 Control Bus Datak5lCBD5 I/O TTL
94 Control Bus Datak6lCBD6 I/O TTL
95 Control Bus Datak7lCBD7 I/O TTL
96 Control Bus Data Parity CBP I/O TTL
97 I/O Ground GNDÐIO a0V
98 I/O Power VCCÐIO a5V
99 Local Symbol Clock LSC O TTL
100 Local Byte Clock5 LBC5 O TTL
131
8.0 Connection Diagrams (Continued)
8.2 DP83256VF-AP CONNECTION DIAGRAM
For a Pinout Summary List, refer to Table 8-2.
TL/F/11708 58
FIGURE 8-2. DP83256VF-AP 100-Pin JEDEC Metric PQFP Pinout
132
8.0 Connection Diagrams (Continued)
TABLE 8-2. DP83256VF-AP 100-Pin PQFP Pinout Summary
Pin No. Signal Name Symbol I/O Pin Type
1 Local Byte Clock 4 LBC4 O TTL
2 Local Byte Clock 3 LBC3 O TTL
3 Local Byte Clock 2 LBC2 O TTL
4 Local Byte Clock 1 LBC1 O TTL
5 Clock 16/32 CLK16 O TTL
6 PHY Port A Indicate Parity AIP O TTL
7 PHY Port A Indicate Control AIC O TTL
8 PHY Port A Indicate Datak7lAID7 O TTL
9 PHY Port A Indicate Datak6lAID6 O TTL
10 PHY Port A Indicate Datak5lAID5 O TTL
11 I/O Power VCCÐIO a5V
12 I/O Ground GNDÐIO a0V
13 PHY Port A Indicate Datak4lAID4 O TTL
14 PHY Port A Indicate Datak3lAID3 O TTL
15 PHY Port A Indicate Datak2lAID2 O TTL
16 PHY Port A Indicate Datak1lAID1 O TTL
17 PHY Port A Indicate Datak0lAID0 O TTL
18 ReservedÐ0 RESÐ0a0V
19 ReservedÐ0 RESÐ0a0V
20 ANALOG Power VCCÐANALOG a5V
21 ANALOG Ground GNDÐANALOG a0V
22 Phase Select PHÐSEL I TTL
23 Reference Select REFÐSEL I TTL
24 Reference Input REFÐIN I TTL
25 Feedback Input FBKÐIN I TTL
26 Crystal Output XTALÐOUT O
27 Crystal Input XTALÐIN I
28 ESD Power VCCÐESD a5V
29 ESD Ground GNDÐESD a0V
30 Transmit ClockbTXCbO ECL
31 Transmit ClockaTXCaO ECL
32 ECL Power VCCÐECL a5V
33 PMD Request Data bPMRDbO ECL
34 PMD Request Data aPMRDaO ECL
35 Receive Clock OutbRXCÐOUTbO ECL
36 Receive Clock OutaRXCÐOUTaO ECL
37 ECL Power VCCÐECL a5V
38 ECL Ground GNDÐECL a0V
133
8.0 Connection Diagrams (Continued)
TABLE 8-2. DP83256VF-AP 100-Pin PQFP Pinout Summary (Continued)
Pin No. Signal Name Symbol I/O Pin Type
39 Signal DetectbSDbI ECL
40 Signal DetectaSDaI ECL
41 PMD Indicate DatabPMIDbI ECL
42 PMD Indicate DateaPMIDaI ECL
43 Enable Pin 0 EP0 O TTL
44 Enable Pin 1 EP1 O TTL
45 ECL Power VCCÐECL a5V
46 ECL Ground GNDÐECL a0V
47 Receive Clock InbRXCÐINbI ECL
48 Receive Clock InaRXCÐINaI ECL
49 Receive Data InbRXDÐINbI ECL
50 Receive Data InaRXDÐINaI ECL
51 Receive Data OutbRXDÐOUTbO ECL
52 Receive Data OutaRXDÐOUTaO ECL
53 No Connect N/C
54 No Connect N/C
55 ECL Ground GNDÐECL a0V
56 ECL Power VCCÐECL a5V
57 ReservedÐ0 RESÐ0a0V
58 ReservedÐ0 RESÐ0a0V
59 PHY Port B Request Datak0lBRD0 I TTL
60 PHY Port B Request Datak1lBRD1 I TTL
61 PHY Port B Request Datak2lBRD2 I TTL
62 PHY Port B Request Datak3lBRD3 I TTL
63 PHY Port B Request Datak4lBRD4 I TTL
64 I/O Ground GNDÐIO a0V
65 I/O Power VCCÐIO a5V
66 PHY Port B Request Datak5lBRD5 I TTL
67 PHY Port B Request Datak6lBRD6 I TTL
68 PHY Port B Request Datak7lBRD7 I TTL
69 PHY Port B Request Control BRC I TTL
70 PHY Port B Request Parity BRP O TTL
71 EDevice Reset ERST I TTL
72 Read/EWrite R/EW I TTL
73 Chip Enable ECE I TTL
74 EInterrupt EINT O Open Drain
75 EAcknowledge EACK O Open Drain
76 Control Bus Addressk0lCBA0 I TTL
134
8.0 Connection Diagrams (Continued)
TABLE 8-2. DP83256VF-AP 100-Pin PQFP Pinout Summary (Continued)
Pin No. Signal Name Symbol I/O Pin Type
77 Control Bus Addressk1lCBA1 I TTL
78 I/O Logic Ground GNDÐIO a0V
79 I/O Logic Power VCCÐIO a5V
80 Control Bus Addressk2lCBA2 I TTL
81 Control Bus Addressk3lCBA3 I TTL
82 Control Bus Addressk4lCBA4 I TTL
83 Control Bus Addressk5lCBA5 I TTL
84 ReservedÐ0 RESÐ0a0V
85 ReservedÐ1 RESÐ1a5V
86 Control Bus Datak0lCBD0 I/O TTL
87 Core Ground GNDÐCORE a0V
88 Core Power VCCÐCORE a5V
89 Control Bus Datak1lCBD1 I/O TTL
90 Control Bus Datak2lCBD2 I/O TTL
91 Control Bus Datak3lCBD3 I/O TTL
92 Control Bus Datak4lCBD4 I/O TTL
93 Control Bus Datak5lCBD5 I/O TTL
94 Control Bus Datak6lCBD6 I/O TTL
95 Control Bus Datak7lCBD7 I/O TTL
96 Control Bus Data Parity CBP I/O TTL
97 I/O Ground GNDÐIO a0V
98 I/O Power VCCÐIO a5V
99 Local Symbol Clock LSC O TTL
100 Local Byte Clock5 LBC5 O TTL
135
8.0 Connection Diagrams (Continued)
8.3 DP83257VF CONNECTION DIAGRAM
For a Pinout Summary List, refer to Table 8-3.
TL/F/11708 45
FIGURE 8-3. DP83257VF 160-Pin JEDEC Metric PQFP Pinout
136
8.0 Connection Diagrams (Continued)
TABLE 8-3. DP83257 160-Pin PQFP Pinout Summary
Pin No. Signal Name Symbol I/O Pin Type
1 Local Byte Clock 4 LBC4 O TTL
2 Local Byte Clock 3 LBC3 O TTL
3 Local Byte Clock 2 LBC2 O TTL
4 Local Byte Clock 1 LBC1 O TTL
5 Clock 16/32 CLK16 O TTL
6 PHY Port A Indicate Parity AIP O TTL
7 PHY Port A Request Parity ARP I TTL
8 PHY Port A Indicate Control AIC O TTL
9 PHY Port A Request Control ARC I TTL
10 PHY Port A Indicate Datak7lAID7 O TTL
11 PHY Port A Request Datak7lARD7 I TTL
12 PHY Port A Indicate Datak6lAID6 O TTL
13 PHY Port A Request Datak6lARD6 I TTL
14 PHY Port A Indicate Datak5lAID5 O TTL
15 PHY Port A Request Datak5lARD5 I TTL
16 I/O Power VCCÐIO a5V
17 I/O Ground GNDÐIO a0V
18 PHY Port A Indicate Datak4lAID4 O TTL
19 PHY Port A Request Datak4lARD4 I TTL
20 PHY Port A Indicate Datak3lAID3 O TTL
21 PHY Port A Request Datak3lARD3 I TTL
22 PHY Port A Indicate Datak2lAID2 O TTL
23 PHY Port A Request Datak2lARD2 I TTL
24 PHY Port A Indicate Datak1lAID1 O TTL
25 PHY Port A Request Datak1lARD1 I TTL
26 PHY Port A Indicate Datak0lAID0 O TTL
27 PHY Port A Request Datak0lARD0 I TTL
28 ReservedÐ0 RESÐ0a0V
29 ReservedÐ0 RESÐ0a0V
30 ReservedÐ0 RESÐ0a0V
31 ReservedÐ0 RESÐ0a0V
32 ANALOG Power VCCÐANALOG a5V
33 ANALOG Ground GNDÐANALOG a0V
34 Phase Select PHÐSEL I TTL
35 Reference Select REFÐSEL I TTL
36 Reference Input REFÐIN I TTL
37 Feedback Input FBKÐIN I TTL
38 No Connect N/C
137
8.0 Connection Diagrams (Continued)
TABLE 8-3. DP83257 160-Pin PQFP Pinout Summary (Continued)
Pin No. Signal Name Symbol I/O Pin Type
39 No Connect N/C
40 No Connect N/C
41 No Connect N/C
42 No Connect N/C
43 No Connect N/C
44 No Connect N/C
45 Crystal Output XTALÐOUT O
46 Crystal Input XTALÐIN I
47 ESD Power VCCÐESD a5V
48 ESD Ground GNDÐESD a0V
49 Loop Filter LPFLTR O
50 Transmit ClockbTXCbO ECL
51 Transmit ClockaTXCaO ECL
52 ECL Power VCCÐECL a5V
53 PMD Request DatabPMRDbO ECL
54 PMD Request Data aPMRDaO ECL
55 Receive Clock OutbRXCÐOUTbO ECL
56 Receive Clock OutaRXCÐOUTaO ECL
57 ECL Power VCCÐECL a5V
58 ECL Ground GNDÐECL a0V
59 Signal DetectbSDbI ECL
60 Signal DetectaSDaI ECL
61 PMD Indicate DatabPMIDbI ECL
62 PMD Indicate DataaPMIDaI ECL
63 Sense Pin 0 SP0 I TTL
64 Enable Pin 0 EP0 O TTL
65 Sense Pin 1 SP1 I TTL
66 Enable Pin 1 EP1 O TTL
67 Sense Pin 2 SP2 I TTL
68 Enable Pin 2 EP2 O TTL
69 Cascade Start CS I TTL
70 Cascade Ready CR O Open Drain
71 ECL Power VCCÐECL a5V
72 ECL Ground GNDÐECL a0V
73 PMD Transmitter Enable TXE O TTL
74 PMD Transmitter Enable Level TEL I TTL
75 Receive Clock InbRXCÐINbI ECL
76 Receive Clock InaRXCÐINaI ECL
138
8.0 Connection Diagrams (Continued)
TABLE 8-3. DP83257 160-Pin PQFP Pinout Summary (Continued)
Pin No. Signal Name Symbol I/O Pin Type
77 Receive Data InbRXDÐINbI ECL
78 Receive Data InaRXDÐINaI ECL
79 No Connect N/C
80 No Connect N/C
81 No Connect N/C
82 Receive Data OutbRXDÐOUTbO ECL
83 Receive Data OutaRXDÐOUTaO ECL
84 ReservedÐ0 RESÐ0a0V
85 ReservedÐ0 RESÐ0a0V
86 ReservedÐ0 RESÐ0a0V
87 No Connect N/C
88 ECL Ground GNDÐECL a0V
89 ECL Power VCCÐECL a5V
90 ReservedÐ0 RESÐ0a0V
91 ReservedÐ0 RESÐ0a0V
92 ReservedÐ0 RESÐ0a0V
93 ReservedÐ0 RESÐ0a0V
94 PHY Port B Indicate Datak0lBID0 O TTL
95 PHY Port B Request Datak0lBRD0 I TTL
96 PHY Port B Indicate Datak1lBID1 O TTL
97 PHY Port B Request Datak1lBRD1 I TTL
98 PHY Port B Indicate Datak2lBID2 O TTL
99 PHY Port B Request Datak2lBRD2 I TTL
100 PHY Port B Indicate Datak3lBID3 O TTL
101 PHY Port B Request Datak3lBRD3 I TTL
102 PHY Port B Indicate Datak4lBID4 O TTL
103 PHY Port B Request Datak4lBRD4 I TTL
104 I/O Ground GNDÐIO a0V
105 I/O Power VCCÐIO a5V
106 PHY Port B Indicate Datak5lBID5 O TTL
107 PHY Port B Request Datak5lBRD5 I TTL
108 PHY Port B Indicate Datak6lBID6 O TTL
109 PHY Port B Request Datak6lBRD6 I TTL
110 PHY Port B Indicate Datak7lBID7 O TTL
111 PHY Port B Request Datak7lBRD7 I TTL
112 PHY Port B Indicate Control BIC O TTL
113 PHY Port B Request Control BRC I TTL
114 PHY Port B Indicate Parity BIP O TTL
139
8.0 Connection Diagrams (Continued)
TABLE 8-3. DP83257 160-Pin PQFP Pinout Summary (Continued)
Pin No. Signal Name Symbol I/O Pin Type
115 PHY Port B Request Parity BRP I TTL
116 EDevice Reset ERST I TTL
117 Read/EWrite R/EW I TTL
118 Chip Enable ECE I TTL
119 EInterrupt EINT O Open Drain
120 EAcknowledge EACK O Open Drain
121 No Connect N/C
122 No Connect N/C
123 No Connect N/C
124 No Connect N/C
125 No Connect N/C
126 No Connect N/C
127 No Connect N/C
128 Control Bus Addressk0lCBA0 I TTL
129 Control Bus Addressk1lCBA1 I TTL
130 I/O Logic Ground GNDÐIO a0V
131 I/O Logic Power VCCÐIO a5V
132 Control Bus Addressk2lCBA2 I TTL
133 Control Bus Addressk3lCBA3 I TTL
134 Control Bus Addressk4lCBA4 I TTL
135 Control Bus Addressk5lCBA5 I TTL
136 ReservedÐ0 RESÐ0a0V
137 ReservedÐ1 RESÐ1a5V
138 Control Bus Datak0lCBD0 I/O TTL
139 Core Ground GNDÐCORE a0V
140 Core Power VCCÐCORE a5V
141 Control Bus Datak1lCBD1 I/O TTL
142 Control Bus Datak2lCBD2 I/O TTL
143 Control Bus Datak3lCBD3 I/O TTL
144 Control Bus Datak4lCBD4 I/O TTL
145 Control Bus Datak5lCBD5 I/O TTL
146 Control Bus Datak6lCBD6 I/O TTL
147 Control Bus Datak7lCBD7 I/O TTL
148 Control Bus Data Parity CBP I/O TTL
149 No Connect N/C
150 No Connect N/C
151 No Connect N/C
140
8.0 Connection Diagrams (Continued)
TABLE 8-3. DP83257 160-Pin PQFP Pinout Summary (Continued)
Pin No. Signal Name Symbol I/O Pin Type
152 No Connect N/C
153 No Connect N/C
154 No Connect N/C
155 No Connect N/C
156 No Connect N/C
157 I/O Ground GNDÐIO a0V
158 I/O Power VCCÐIO a5V
159 Local Symbol Clock LSC O TTL
160 Local Byte Clock5 LBC5 O TTL
141
9.0 Package Information
The information contained in this section describes the two packages used for the PLAYERadevice.
Land pattern information is provided to assist in surface mount layout using each of the available PLAYERadevice packages.
Mechanical drawings of each of the packages are also provided.
9.1 LAND PATTERNS
TL/F/11708 46
FIGURE 9-1. Layout Land Patterns
TABLE 9-1. Layout Land Pattern Dimensions
Device A (mm) B (mm) P (mm) X (mm)
DP83256VF and DP83256VF-AP 14.60 18.45 0.50 0.35
14mm x 14mm x 2.0mm
100-lead JEDEC FPQFP
DP83257VF 28.90 33.40 0.65 0.45
28mm x 28mm x 3.42mm
160-lead JEDEC MQFP
9.2 MECHANICAL DRAWINGS
The following two pages contain the mechanical drawings for each of the available PLAYERadevice packages.
142
Physical Dimensions millimeters
Plastic Quad Flatpak (VJU)
Order Number DP83256VF and DP83256VF-AP
NS Package Number VJU100A
143
DP83256/56-AP/57 PLAYERaDevice (FDDI Physical Layer Controller)
Physical Dimensions millimeters (Continued)
Plastic Quad Flatpak (V)
Order Number DP83257VF
NS Package Number VUL160A
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT
DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF NATIONAL
SEMICONDUCTOR CORPORATION. As used herein:
1. Life support devices or systems are devices or 2. A critical component is any component of a life
systems which, (a) are intended for surgical implant support device or system whose failure to perform can
into the body, or (b) support or sustain life, and whose be reasonably expected to cause the failure of the life
failure to perform, when properly used in accordance support device or system, or to affect its safety or
with instructions for use provided in the labeling, can effectiveness.
be reasonably expected to result in a significant injury
to the user.
National Semiconductor National Semiconductor National Semiconductor National Semiconductor
Corporation Europe Hong Kong Ltd. Japan Ltd.
1111 West Bardin Road Fax: (
a
49) 0-180-530 85 86 13th Floor, Straight Block, Tel: 81-043-299-2309
Arlington, TX 76017 Email: cnjwge
@
tevm2.nsc.com Ocean Centre, 5 Canton Rd. Fax: 81-043-299-2408
Tel: 1(800) 272-9959 Deutsch Tel: (
a
49) 0-180-530 85 85 Tsimshatsui, Kowloon
Fax: 1(800) 737-7018 English Tel: (
a
49) 0-180-532 78 32 Hong Kong
Fran3ais Tel: (
a
49) 0-180-532 93 58 Tel: (852) 2737-1600
Italiano Tel: (
a
49) 0-180-534 16 80 Fax: (852) 2736-9960
National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications.