POWER
LCC250
250 Watts Convection/Conduction Mounting
Total Power: 250 W
# of Outputs: Single
Outputs: 12, 24, 48 V
SPECIAL FEATURES
250 W full power at elevated
temperatures
Wide operating temperature range
suited for outdoor application
IP64 rated
Conduction-cooled or convection
Differential remote sense
Output adjust
Output On/Off (Positive or Negative
logic user selectable)
COMPLIANCE
EMI Class B
EN61000 Immunity
MIL-STD-461E: CE101; CE102;
CS101; CS114
SAFETY5
UL + CSA 60950-1 2nd Ed.
ANSI ES60601-1
3rd Ed
TÜV 60950-1 2nd Ed.
60601-1 3rd Ed.
61347-1; 2-13
CB Scheme IEC 60950-1 2nd Ed
IEC 61347-1; 2-13
IEC 60601-1
China CCC
CE Mark
Electrical Specications
Input
Input ra nge 90 - 264 Vac (Operating)
115/230 Vac (Nominal)
Frequency 47 - 63 Hz
Input fusing Internal fuse on both L and N lines
Inrush current 50 A
Power factor > 0.92 Full load
Harmonics Meets EN61000-3-2; MIL-STD-461E(6); CE101; CE102; CS101; CS104
Input current 3.4 A @ 90 Vac full load
Hold up time 16 ms minimum at 115 Vac; 100% load
Efficiency 230 Vac; 100% load
12 V - 89% typical
24 V - 91% typical
48 V - 91.5% typical
Leakage current < 275 μA at 230 Vac
Data Sheet
LCC250 Data Sheet
Environmental Specications
Operating temperature Suffix 4P (Conduction): -40 °C to +85 °C Baseplate Temperature
Suffix 7P (Convection): -40 °C to +85 °C Ambient Temperature
Storage temperature -40 °C to +85 °C
Humidity 10% to 100% (Condensing & Non-Condensing)
Altitude Operating: 13,000 feet
Non-Operating: 50,000 feet
Shock IEC68-2-27
Vibration IEC68-2-6 / IEC721-3-2
Ingress protection IP64 Rated
MTBF (calculated) > 780,000 hours at 100% load; Low line; Telcordia SR-332
Electrical Specications
Output
Output rating 12 V @ 20.8 A
24 V @ 10.4 A
48 V @ 5.2 A
Set point ±0.2% Factory set point
Total regulation range ±2% Line/Load/Temperature
Rated load 250 W maximum
Minimum load 0 A Load No loss of regulation
Capacitive load 0 - 330 μF/Amp
Output voltage overshoot No overshoot/undershoot outside the regulation band during
on or off cycle
Constant output voltage adjustment range 12 V: +10 / -10%
24 V: +14.6 / -15%
48 V: +15% / -15%
Adjust via VR2
Constant output current adjustment range +0 / -50% Adjust via VR1
CC mode supported from Vo nominal down to 80% Vo
Output ripple and noise 1% 0 to 330 μF/Amp
Transient response ±5% Vo max transient;
recovery < 500 μs max
50% Load Step @ 1 A/μs
Step Load verified at: 50% to 100% Load; 90 - 264 Vac
input; Capacitive load from 0 to 330 μF/Amp
Remote sense Capable of Stable Offset of ±0.5 Vdc at output
cable termination
+SENSE (Red Wire); -SENSE (Black Wire)
Output On/Off Remote On/Off referenced to secondary side.
Positive or Negative logic user selectable via CN2.
Factory default is Positive logic
On/Off (Orange Wire); On/Off Return (White Wire)
Overcurrent protection (OCP) ≤ 150% Io Auto-recovery
Overvoltage protection (OVP) 110% to 135% Vo Latching mode; Requires input AC recycle
Overtemperature protection (OTP) Auto-recovery; hiccup mode
Output isolation 3000 Vac Input to Output
1500 Vac Input to Ground
500 Vac Output to Ground
LCC250 Data Sheet
1. Output ripple measured at the end of the output cable terminated with 10 μF tantalum cap in parallel with 0.1 μF ceramic capacitor.
2. 12 V: 1% limit is achieved with 2X 820 uF/16 V external cap (e.g. PLG1C821MDO1 from Nichicon or equivalent). Otherwise, maximum
limits are 1.5% at Ta ≥ 0 °C and 2.0% max at Ta < 0 °C.
3. 24 V: 1% limit is achieved with 2X 820 uF/35 V external cap (e.g. UPM1V821MHD1TO from Nichicon or equivalent). Otherwise,
maximum limits are 1.5% at Ta ≥ -10 °C. 2.0% max ripple at Ta < -10 °C is met with below external capacitance:
4. 48 V: 1% limit is achieved with 3X 470 uF/63 V external cap. Otherwise, maximum limits are 1.5% max at Ta ≥ 0 °C and 2% max at
Ta < 0 °C.
5. Two (2) LCC250 model numbers exist with same electrical performance except for safety approvals as shown below:
• LCC250-XXu-xPE version = Europe/China safety approved & carries CE/TÜV & CCC logos
• LCC250-XXu-xP version = Europe/USA safety approved & carries CE/TÜV & cUL logos
6. 12 V unit requires external filtering for MIL-STD-461E compliance. Consult Artesyn Technical Support.
7. Warranty: 2 years
Ordering Information
Model Number Output Adjustment Range
Output Current Output Ripple
P/P1
Line/
Load Regulation
Min Max
LCC250-12U-4P 12 V ±10% 0 A 20.8 A 1% 2±2%
LCC250-12U-4PE 12 V ±10% 0 A 20.8 A 1% 2±2%
LCC250-12U-7P 12 V ±10% 0 A 20.8 A 1% 2±2%
LCC250-12U-7PE 12 V ±10% 0 A 20.8 A 1% 2±2%
LCC250-24U-4P 24 V +14.6 / -15% 0 A 10.4 A 1% 3±2%
LCC250-24U-4PE 24 V +14.6 / -15% 0 A 10.4 A 1% 3±2%
LCC250-24U-7P 24 V +14.6 / -15% 0 A 10.4 A 1% 3±2%
LCC250-24U-7PE 24 V +14.6 / -15% 0 A 10.4 A 1% 3±2%
LCC250-48U-4P 48 V ±15% 0 A 5.2 A 1% 4±2%
LCC250-48U-4PE 48 V ±15% 0 A 5.2 A 1% 4±2%
LCC250-48U-7P 48 V ±15% 0 A 5.2 A 1% 4±2%
LCC250-48U-7PE 48 V ±15% 0 A 5.2 A 1% 4±2%
Ambient Temperature (°C) -20 -25 -30 -35 -40
Recommended External Capacitors (μF) 1000 2200 3300 12000 22000
LCC250 Data Sheet
Fig 4. 12 V Efficiency Curve
0
2
4
6
8
10
12
25 35 45 55 65 75 85
100 LFM
NAT CONV
200 LFM
300 LFM
400 LFM
Output Current (A)
Ambient Temperature (˚C)
LCC250-24U-7P (Convection)
VIN = 115 Vac
Fig 5. 24 V “4P” Suffix (Conduction) Output Current Derating
0
2
4
6
8
10
12
25 35 45 55 65 75 85 95
Output current (A)
Baseplate Temperature (˚C)
LCC250-24U-4P (Conduction)
90 Vac
115 Vac
230 Vac
264 Vac
Fig 2. 12 V “7P” Suffix (Convection) Output Current Derating at 115 Vac
0
5
10
15
20
25
25 35 45 55 65 75 85 95
Output Current (A)
Baseplate Temperature (˚C)
LCC250-12U-4P (Conduction)
230 Vac
180 Vac
115 Vac
90 Vac
115/180/230 Vac
Fig 1. 12 V “4P” Suffix (Conduction) Output Current Derating
Fig 3. 12 V “7P” Suffix (Convection) Output Current Derating at 230 Vac
Fig 6. 24 V “7P” Suffix (Convection) Output Current Derating at 115 Vac
65%
70%
75%
80%
85%
90%
95%
0% 20% 40% 60% 80% 100%
Efciency (%)
Output Load
12V Efciency vs. Input Line
Vin = 115 Vac
Vin = 230 Vac
0
5
10
15
20
25
25 35 45 55 65 75 85
Output Current (A)
Ambient Temperature (˚C)
LCC250-12U-7P (Conduction)
VIN = 230 Vac
NAT CONV
100 LFM
200 LFM
300 LFM
400 LFM
0
5
10
15
20
25
25 35 45 55 65 75
85
Output Current (A)
Ambient Temperature (˚C)
LCC250-12U-7P (Convection)
VIN = 115 Vac
NAT CONV
100 LFM
200 LFM
300 LFM
400 LFM
LCC250 Data Sheet
Fig 10. 48 V “7P” Suffix (Convection) Output
65
70
75
80
85
90
95
020406080 100
Efciency (%)
Output Load (%)
48 V Efciency vs. Input Line
Vin=115 Vac
Vin=230 Vac
Fig 11. 48 V “7P” Suffix (Convection) Output Current Derating at 230 Vac
0
1
2
3
4
5
6
25 35 45 55 65 75 85
100 LFM
NAT CONV
200 LFM
300 LFM
400 LFM
Output Current (A)
Ambient Temperature (˚C)
LCC250-48U-7P (Convection)
VIN = 230 Vac
Fig 8. 24 V Efficiency Curve
0
2
4
6
8
10
12
25 35 45 55 65 75 85
100 LFM
NAT CONV
200 LFM
300 LFM
400 LFM
Output Current (A)
Ambient Temperature (˚C)
LCC250-24U-7P (Convection)
VIN = 230 Vac
Fig 7. 24 V “7P” Suffix (Convection) Output Current Derating at 230 Vac
Fig 9. 48 V “4P” Suffix (Conduction) Output Current Derating
Fig 12. 48 V Efficiency Curve
0
1
2
3
4
5
6
25 35 45 55 65 75 85
100 LFM
NAT CONV
200 LFM
300 LFM
400 LFM
Output Current (A)
Ambient Temperature (˚C)
LCC250-48U-7P (Convection)
VIN = 115 Vac
0
1
2
3
4
5
6
25 35 45 55 65 75 85 95
Output Current (A)
Baseplate Temperature (˚C)
LCC250-48U-4P (Conduction)
90 Vac
115 Vac
230 Vac
264 Vac
65
70
75
80
85
90
95
020406080
100
Efciency (%)
Output Load (%)
24 V Efciency vs. Input Line
115 Vac
230 Vac
LCC250 Data Sheet
Mechanical Drawings
POTTING TRIM LABEL
MODEL LABEL
6-Ø 3.6 ±0.10 L2
DC OUTPUT
L1
AC INPUT
(4 - 63.5)
(2 - 93.8)
101.4 ±0.6
L3
CONTROL
BA
BA
BA
BAM
BUSHING
ADJUST DIMMING
(VR1)
ADJUST REMOTE ON/OFF
(CN2)
SEE DETAIL C
ADJUST OUTPUT VOLTAGE
(VR2)
VIEW M
ON
(NEGATIVE POLARITY)
OFF
(POSITIVE POLARITY)
DETAIL C
37.6 ±0.6
LCC250-12U-7P
27.9 ±0.6
LCC250-12U-4P
0.30 SERIAL NO. BARCODE LABEL
CC
C
C
C
C
177.6 ±0.6
(2 - 139.7)
(2 - 119.4)
(2 - 119.4)
(2 - 59.7) (See DETAIL C)
12 V
MODEL LABEL
L2
DC OUTPUT
L1
AC INPUT
POTTING TRIM LABEL
BUSHING
37.6 ±0.6
LCC250-xxU-7P
27.9 ±0.6
LCC250-xxU-4P
177.6 ±0.6
(2 - 139.7)
(2 - 119.4)
(2 - 119.4)
(2 - 59.7)
(4 - 63.5)
(2 - 93.8)
101.4 ±0.6
L3
CONTROL
B
B
B
BA
A
A
A
C
CC
C
CC
6-Ø 3.6 ±0.10
0.30
(FOR 4PE/7PE ONLY)
SERIAL NO. BARCODE LABEL
See DETAIL C
Available Mounting Holes for “-7P” Sufx
(with Heatsink)
Mounting Hole “A
4X locations (Top Cover Side)
#6-23 thread
Mounting Hole “B
4X locations (Top Cover Side)
M3X0.5 thread
For both “A” and “B” Mounting Holes,
screw length should be <4.0mm/Torque
8KG-F Max.
DETAIL C
24 V / 48 V
LCC250 Data Sheet
WORLDWIDE OFFICES
Americas
2900 S.Diablo Way
Tempe, AZ 85282
USA
+1 888 412 7832
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
+44 (0) 1384 842 211
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
+852 2176 3333
For more information: www.artesyn.com/power
For support: productsupport.ep@artesyn.com
www.artesyn.com
Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and
service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names,
trademarks, or registered trademarks of their respective owners. Specifications are subject to change without
notice. © 2018 Artesyn Embedded Technologies, Inc. All rights reserved. For full legal terms and conditions,
please visit www.artesyn.com/legal.
LCC250 DS 29Aug2018
Cable Length Designation Wire Color Wire Gauge
AC Input Cable L1 = 300 ±10 mm L = Live Brown AWG#18
N = Neutral Blue AWG#18
PE = Primary Earth Green/Yellow AWG#18
DC Output Cable L2 = 300 ±10 mm +Output Blue AWG#14
-Output Gray AWG#14
Control Cable L3 = 300 ±10 mm Dimming Brown AWG#26
Dimming Return Yellow AWG#26
ON/OFF Orange AWG#26
ON/OFF Return White AWG#26
Sense Red AWG#26
Sense Return Black AWG#26
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Artesyn Embedded Technologies:
LCC250-24U-4PE LCC250-24U-7PE LCC250-48U-4P LCC250-48U-4PE LCC250-48U-7P LCC250-48U-7PE
LCC250-12U-4P LCC250-12U-4PE LCC250-12U-7P LCC250-12U-7PE LCC250-24U-4P LCC250-24U-7P