The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Jan 23, 2014
1
Product data sheet
Characteristics XPSMC16Z
safety controller XPS-MC - 24 V DC - 16 input -
30 LEDs signalling
Main
Commercial Status Commercialised
Range of product Preventa Safety automation
Product or component
type
Configurable safety controller
Safety module name XPSMC
Safety use category SIL 3 maximum conforming to IEC 61508
PLE maximum conforming to EN/ISO 13849-1
Category 4 maximum conforming to EN 954-1/EN/
ISO 13849-1
Type of start Configurable
Standards EN 1760-1/ISO 13856-1
EN 574/ISO 13851
EN 954-1/EN/ISO 13849-1
EN/IEC 60204-1
EN/IEC 60947-5-1
EN/IEC 61496-1
IEC 61508
Product certifications CSA
TÜV
UL
[Us] rated supply volt-
age
24 V DC - 20...20 %
Number of inputs 16
Communication port
protocol
Modbus with 1 RJ45 port(s), serial link, transmis-
sion rate: 1200 bps, 2400 bps, 4800 bps, 9600 bps
or 19200 bps
Safety level Can reach SIL 3 conforming to IEC 61508
Can reach PL e/category 4 conforming to EN 954-1/
EN/ISO 13849-1
Complementary
Function of module Two-hand control (category 3) conforming to EN 574/ISO 13851
Light curtain monitoring (category 4) conforming to EN/IEC 61496
Zero speed detection
Shaft/Chain breaking monitor
Safety time delays
Safety mat monitoring
Position selector
Muting function of light curtains
Monitoring safety stop at top dead centre on eccentric press
Magnetic switch monitoring
Hydraulic press
Guard monitoring with 1 or 2 limit switches
Guard monitoring for injection presses and blowing machines
Foot switch monitoring
Enabling switch monitoring, 2 or 3 contacts
Emergency stop monitoring, with or without time delay, 1 or 2-channel wiring
Eccentric press
Dynamic monitoring of hydraulic valves on linear presses
Synchronisation time between inputs Depending on configuration selected
Power consumption 12 W
Input protection type External fuse 16 A
[Uc] control circuit voltage 28.8 V
Line resistance 100 Ohm, cable length: <= 2000 m
Output type Solid state, 6 circuit(s), volt-free
2 relays, 2 NO contacts (4 NO total) circuit(s)
Breaking capacity C300: inrush 1800 VA AC-15 for relay output
C300: holding 180 VA AC-15 for relay output
2
Breaking capacity 1.5 A/24 V - L/R = 50 ms, DC-13 for relay output
2 A/24 V for static output circuit
Output thermal current 6 A for 1 output and 2 A for the other for relay output
4 A for both outputs simultaneously
[Ith] conventional free air thermal current <= 6.5 A for static output circuit
<= 16 A for relay output
Associated fuse rating 6 A fast blow for relay output
4 A gL for relay output
16 A gL for power supply
Minimum output current 10 mA for relay output
Minimum output voltage 17 V for relay output
Response time Configurable : 20 ms or 30 ms with software XPSMCWIN
[Ui] rated insulation voltage 300 V, degree of pollution 2 conforming to IEC 60647-5-1, DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage 4 kV overvoltage category III conforming to IEC 60647-5-1, DIN VDE 0110 part 1
Method of access Slave
Exchange size 14 words
Number of addresses 1...247 for Modbus
Parity Odd for Modbus
No for Modbus
Even for Modbus
Data format RTU (Remote Terminal Unit) mode
2 stop bits without parity
1 stop bit even or odd
1 start bit/8 data bits
Supported modbus function 03: information and errors
02: 32-bit input data/8-bit output data
01: 8-bit output data/32-bit input data
Local signalling 30 LEDs
Mounting support Mounting plate
Depth 153 mm
Height 151.5 mm
Width 74 mm
Product weight 0.82 kg
Environment
IP degree of protection IP20 conforming to EN/IEC 60529
Ambient air temperature for operation -10...55 °C
Ambient air temperature for storage -25...85 °C
Contractual warranty
Period 18 months
3
Product data sheet
Dimensions Drawings XPSMC16Z
Dimensions
1 When using XPSMCTS• connectors this dimension is 153 mm (6.02 in)
When using XPSMCTC• connectors this dimension is 151,5 mm (5.96 in)
4
Product data sheet
Mounting and Clearance XPSMC16Z
Installation
Metal adaptor for fixing on metal: DIN rail 35mm/1.38in.
5
Product data sheet
Connections and Schema XPSMC16Z
Wiring Diagrams
Refer to the Instruction Sheet
To download the instruction sheet, follow below procedure:
1 Click on Download & Documents.
2 Click on Instruction sheet.
6
Product data sheet
Technical Description XPSMC16Z
Safety Functions
Emergency stop monitoring with time delay:
1 channel wiring, with automatic start.
2 channel wiring, with start button.
Emergency stop monitoring without time delay:
1 channel wiring, with automatic start.
2 channel wiring, with start button.
Two-hand control.
Guard monitoring:
with 1 limit switch.
with 2 limit switches.
with 2 limit switches, with guard locking.
Guard monitoring for injection presses and blowing machines.
Magnetic switch monitoring.
Sensing mat monitoring.
Light curtains monitoring:
Relay output type.
Solid-state output type.
“Muting” function for light curtains.
Zero speed detection.
Dynamic monitoring of hydraulic valves on linear presses.
7
Safety time delays.
Monitoring safety stop at top dead centre on eccentric press.
Hydraulic press.
Eccentric press.
Enabling switching monitoring:
2 contact type.
3 contact type.
Other functions:
Foot switch monitoring
Chain shaft breakage monitoring
Position selector