For the Latest Information
On the Internet: www.sti.com or www.omron.ca
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
G
G40
Guard Lock Safety-Door Switch
• Release protective cover locks using controller signals or pushbut-
ton switches after the cutting tool stops moving due to inertia
• A mechanical lock is applied automatically when the Operation
Key is inserted. A high level of safety is achieved using a mecha-
nism where the lock is only released when voltage is applied to the
solenoid.
• Conforms to EN (TÜV) standards corresponding to the CE marking
• Certified by UL, CSA and CCC standards
• The Switch contact is opened by a direct opening mechanism (NC
contacts only) when the protective cover is opened.
Direct opening mechanism that is EN-certified is indicated by
on the Switch
• Auxiliary release key ensures easy maintenance and unlocks the
door in the case of a power failure.
• Tough aluminum die-cast body incorporating a switch box with
degree of protection satisfying IP67, UL, and CSA TYPE6P, 13
• Equipped with a horizontal and vertical conduit opening
• Models incorporating easy-to-see indicators for monitoring and
those using an adjustable Operation Key for a swinging door are
available
• The mounting direction of the head can be changed to allow the
Operation Key to be inserted from four directions
Safety Interlock Switches
D4BL D4BL
Standards and EC Directives
Conforms to the following EC Directives:
• Machinery Directive
• Low Voltage Directive
• EN 1088
Certified Standards
Certification
body Standard File No.
TÜV Rheinland
EN 60947-5-1
(certified direct opening)
GS-ET-19
R9451050
UL UL 508 E76675
CSA CSA C22.2, No. 14 LR45746
CQC (CCC) GB14048.5 2003010305073836
Specifications
Certified Standard Ratings
TÜV (EN 60947-5-1), CCC (GB14048.5)
Item Standard Model Indicator Model
Utilization category AC-15 AC-15
Rated operating current (Ie) 3 A 6 A
Rated operating voltage (Ue) 250 V 115 V
Note: Use a 10 A fuse type gI or gG that conforms to IEC 60269 as a short-
circuit protection device.
UL/CSA (UL 508, CSA C22.2 No. 14)
A300
Rated
voltage
Carry
current
Current (A) Volt-amperes (VA)
Make Break Make Break
120 VAC 10 A 60 6 7,200 720
240 VAC 30 3
Note: The UL/CSA certified rating for products with indicators (-A) is
6 A/115 VAC.