21
APPLICATIONS
• Commodity Product: 2 families
ND or NE : general purpose
NV : professional
• Alarm and temperature measurement application
• Temperature regulation application
• Level detection application
• Compensation application
TECHNOLOGY
• ND: epoxy-phenolic resin coating
NE: epoxy resin coating (recommended for severe
mounting conditions)
NV: epoxy varnish coating
• Leads: Radial copper wire tinned
• Marking: on package only for ND03 & NE03
ND/NE 06/09:Nominal resistance and tolerance for
±5%, ±10%
NV06/09: Nominal resistance and tolerance
• Delivery Mode: Bulk, reeled or ammopacked
PERFORMANCE CHARACTERISTICS
Types General purpose Professional
ND03 or NE03 ND06 or NE06 ND09 or NE09 NV06 NV09
Climatic category 55/125/56-434 55/125/56-434
Operating Temperature –55 to +150°C –55 to +150°C –55 to +150°C –55 to +150°C –55 to +150°C
Tolerance on Rn 330Ωto 1MΩ: ± ±5%, ±10%, ±20% ±5%, ±10%, ±20% ±2%, ±5%, ±10% ±2%, ±5%, ±10%
(25°C) 5, 10, 20%
1500Ωto 150 kΩ: ±
3%
Maximum dissipation
at 25°C 0.25 W 0.71 W 0.9 W 0.69 W 0.85 W
Thermal dissipation
factor 5 mW/°C 7.1 mW/°C 9 mW/°C 6.9 mW/°C 8.5 mW/°C
Thermal time constant 10 s 22 s 30 s 18 s 30 s
Response time < 3s
STANDARDIZATION
NV range : approved by NFC 93271
Type: TN115 A for NV06
TN116 for NV09
List: GAM-T1
List: LNZ
OPTIONS
Consult factory for availability of options:
• other nominal resistance values
• other tolerances
• alternative lead materials or lengths
• controlled dimensions
Leaded Discs
N.03
N.06
N.09
NTC Disc Thermistors
ND 03/06/09 • NE 03/06/09 • NV 06/09