2. Specifications
Nominal coil
voltage Set voltage
(at 20C 68F)Reset voltage
(at 20C 68F)
Nominal operating
current
[10%] (at 20C 68F)
Coil resistance
[10%] (at 20C 68F)Nominal operating
power Max. applied voltage
(at 20C 68F)
Set coil Reset coil Set coil Reset coil Set coil Reset coil
1.5V DC
80%V or less of
nominal voltage*
(Initial)
80%V or less of
nominal voltage*
(Initial)
46.7mA 46.7mA 32.132.1
70mW 70mW 150%V of
nominal voltage
3V DC 23.3mA 23.3mA 129129
4.5V DC 15.6mA 15.6mA 289289
6V DC 11.7mA 11.7mA 514514
9V DC 7.8mA 7.8mA 1,1571,157
12V DC 5.8mA 5.8mA 2,0572,057
24V DC 6.3mA 6.3mA 3,8403,840150mW 150mW
Characteristics Item Specifications
Contact
Arrangement 2 Form C
Initial contact resistance, max. Max. 100 m (By voltage drop 6 V DC 1A)
Contact material Standard contact: Ag+Au clad, AgPd contact (low level load): AgPd+Au clad (stationary),
AgPd (movable)
Rating
Nominal switching capacity 1 A 30 V DC (resistive load)
Max. switching power 30 W (DC) (resistive load)
Max. switching voltage 110V DC
Max. switching current 1 A
Min. switching capacity (Reference value)*1
*1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual
load. (AgPd contact type is available for low level load switching [10V DC, 10mA max. level].)
10A 10mV DC
Nominal operating
power
Single side stable 50 mW (1.5 to 12 V DC), 70 mW (24 V DC)
1 coil latching 35 mW (1.5 to 12 V DC), 50 mW (24 V DC)
2 coil latching 70 mW (1.5 to 12 V DC), 150 mW (24 V DC)
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000M (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 750 Vrms for 1min. (Detection current: 10mA)
Between contact and coil 1,800 Vrms for 1min. (Detection current: 10mA)
Between contact sets 1,000 Vrms for 1min. (Detection current: 10mA)
Surge breakdown
voltage (Initial) Between open contacts 1,500 V (10160s) (FCC Part 68)
Between contacts and coil 2,500 V (210s) (Telcordia)
Temperature rise (at 20C 68F)Max. 50C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 1A.)
Operate time [Set time] (at 20C 68F)Max. 5 ms [Max. 5 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.)
Release time [Reset time] (at 20C 68F)Max. 5 ms [Max. 5 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.) (without diode)
Mechanical
characteristics
Shock resistance Functional Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10s.)
Destructive Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10s.)
Destructive 10 to 55 Hz at double amplitude of 5 mm
Expected life Mechanical Min. 5107 (at 180 times/min.)
Electrical Min. 2105 (1 A 30 V DC resistive) (at 20 times/min.)
Conditions Conditions for operation, transport and storage*2
*2 Refer to “6. Usage, Storage and Transport Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
Ambient temperature: –40C to +70C –40F to +158F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed (at rated load) 20 times/min.
Unit weight Approx. 2 g .071 oz