ZP40/60 Series
Features
u Single and Multiple Outputs
u Wide Range AC Input
u Low profi le, Industry Standard Footprint
u Global Safety Agency Compliance
u EN61000-4 Immunity
u Up to 88% effi ciency
2 x 4” 40W to 60W AC-DC Power Supplies
Model ZPS40 ZPS60 ZPD40 ZPT40
Input Voltage range - 90 - 264VAC (47 - 440Hz) or 120 - 370VDC
Inrush Current (132/265VAC) A 25 / 50 (cold start)
Input Current (115/230VAC) A 1.6 / 1.0
Temperature Coeffi cient - ±0.05%/°C
Voltage Accuracy % ±1% V1: ±3%, V2: ±4%, V3: ±3%
Minimum Load A None V1: 0.4A, V2: 0.2A
Load Regulation (1) % ±1% V1: ±3%, V2: ±5%, V3: ±1%
Line Regulation (2) % ±0.5% V1: ±1%, V2: ±2%, V3: ±1%
Ripple & Noise (3)(4) mV 1% or 50mV whichever is greater
Short Circuit Protection - Continuous - hiccup mode
Overvoltage Protection V Typically 110-130% of nominal
Hold Up Time (Typ) ms 8ms at 115VAC input
LED Indicator - Green LED = OK None
Operating Temperature (5) 0 to +70°C, derate linearly to 50% load from 50°C to 70°C
Storage Temperature - -20 to +85°C
Humidity (non condensing) - 10 - 95% RH
Cooling - Convection
Withstand Voltage Input to Ground 1.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
Isolation Resistance >100M at 25C & 70%RH, Output to Ground 500VDC
Vibration (non operating) 23.52m/s2 (10 - 55Hz: constant sweep 1 min X, Y, Z for 1 hour)
Shock - < 196.1 m/s2 (20G)
Safety Agency Approvals - UL60950, CSA60950, EN60950, CE Mark (LVD)
Conducted & Radiated EMI - EN55022-B, FCC Class B
Immunity - EN61000-4-2,-3,-4,-6,-8
Weight (Typ) g (oz) 170g (6oz)
Size (WxLxH) in 2 x 4 x 1.2 (including underside components )
Warranty yrs One Year
Specifi cations
Notes:
(1) ZPD, ZPT for a 60% to 100% or 100% to 60% change in load
(2) ZPT40-3512N V2: ±3%, ZPS/ZPD40: 100-240VAC
(3) Measured with 0.1uF ceramic & 10uF electrolytic at 20MHz BW
(4) ZPT40-3512N, V1 & V2 100mV
(5) ZPS40 (3.3V to 9V models), ZPS60 (3.3V to 12V models) derate linearly to 25% load from 40°C to 70°C
Key Market Segments & Applications
ZPS40, 60 Not Recommended
For New Designs - See ZPSA Series