PS21A79
Intellimod™ Module
Dual-In-Line Intelligent Power Module
50 Amperes/600 Volts
Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272
3Rev. 08/09
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics Symbol Test Conditions Min. Typ. Max. Units
IGBT Inverter Sector
Collector-Emitter Saturation Voltage VCE(sat) I
C = 50A, Tj = 25°C, VD = VDB = 15V, VIN = 5V — 1.55 2.05 Volts
I
C = 50A, Tj = 125°C, VD = VDB = 15V, VIN = 5V — 1.65 2.10 Volts
Diode Forward Voltage VEC T
j = 25°C, -IC = 50A, VIN = 0V — 1.70 2.20 Volts
Inductive Load Switching Times ton 1.80 2.40 — µs
t
rr V
CC = 300V, VD = VDB = 15V, — 0.30 — µs
t
C(on) I
C = 50A, Tj = 125°C, VIN = 0 ⇔ 5V, — 0.40 — µs
t
off Inductive Load (Upper-Lower Arm) — 3.00 — µs
t
C(off) — 0.65 — µs
Collector-Emitter Cutoff Current ICES V
CE = VCES, Tj = 25°C — — 1.0 mA
V
CE = VCES, Tj = 125°C — — 10 mA
Control Sector
Circuit Current ID VD = VDB = 15V, VIN = 5V, — — 7.00 mA
Total of VP1-VPC, VN1-VNC
V
D = VDB = 15V, VIN = 5V, — — 0.55 mA
V
UFB-VUFS, VVFB-VVFS, VWFB-VWFS
VD = VDB = 15V, VIN = 0V, — — 7.00 mA
Total of VP1-VPC, VN1-VNC
V
D = VDB = 15V, VIN = 0V, — — 0.55 mA
V
UFB-VUFS, VVFB-VVFS, VWFB-VWFS
Fault Output Voltage VFOH V
SC = 0V, FO Terminal Pull-up to 5V by 10kΩ 4.9 — — Volts
V
FOL V
SC = 1V, IFO = 1mA — — 0.95 Volts
Input Current IIN V
IN = 5V 1.0 1.5 2.0 mA
Short-Circuit Trip Level* ISC -20°C ≤ TC ≤ 100°C, VD = 15V, RS = 21.5Ω 85.0 — 150.0 Amps
Supply Circuit Undervoltage UVDBt Trip Level, TC ≤ 100°C 10.0 — 12.0 Volts
Protection UVDBr Reset Level, TC ≤ 100°C 10.5 — 12.5 Volts
UVDt Trip Level, TC ≤ 100°C 10.3 — 12.5 Volts
UVDr Reset Level, TC ≤ 100°C 10.8 — 13.0 Volts
Fault Output Pulse Width** tFO C
FO = 22nF 1.0 1.8 — ms
ON Threshold Voltage Vth(on) Applied between UP
, VP
, WP-VPC, 2.1 2.3 2.6 Volts
OFF Threshold Voltage Vth(off) U
N, VN, WN-VNC 0.8 1.4 2.1 Volts
Temperature Output VOT At LVIC Temperature = 85°C 3.50 3.63 3.76 Volts
* Short-Circuit protection is functioning only at the lower arms. Please select the value of the external shunt resistor such that the SC trip level is less than 85A.
**Fault signal is asserted when the lower arm short circuit or control supply under-voltage protective functions operate. The fault output pulse-width tFO depends on the capacitance value
of CFO according to the following approximate equation: CFO = (12.2 x 10-6 x tFO [F]).
***When the temperature rises excessively, the controller (MCU) should stop the DIPIPM.