1
PHOTOELECTRIC SENSORS
E3FA/E3RA/E3FB/E3RB
M18 Plastic and Metal Housing Sensors
Universal M18 cylindrical plastic or nickel-plated brass housing in straight
or 90° angled models
Rugged IP67, IP69K housing withstands high-pressure and
high-temperature wash down
High power red LED for easy sensor alignment and dependable outputs
in dusty environments
Compact and robust housing for easy integration into machines
Retro-reflective models are polarized to prevent false reads on mirrored surfaces
High EMC protection and ambient light immunity for detection stability
in environments with excess noise or background light
The short body of the E3FA/E3RA fits in
tighter mounting spaces.
Flush mounting option for quick and
easy installation.
Bright LED indicators for status visibility
and large sensor adjustors for use with a
standard size screwdriver.
Visible red LED light for easy alignment. Transparent object detection sensors utilize
Omrons unique technology for detecting
objects with birefringent (double refraction)
properties.
Unrivaled Detection with Simplicity in Setup and Installation
High power LED to compensate for dirt
and misalignment.
E3FA/E3RA/E3FB/E3RB
2
Ordering Information
Sensors (E3FA Plastic housing) [Refer to Dimensions on page 16.]
*1. The set type includes the emitter and receiver.
*2. The Reflector is sold separately. Select the Reflector model most suited to the application.
Sensor type Sensing distance Connection method Model
NPN output PNP output
Through-beam *1.
pre-wired
set E3FA-TN11 2M set E3FA-TP11 2M
Emitter E3FA-TN11-L 2M
Receiver E3FA-TN11-D 2M
Emitter E3FA-TP11-L 2M
Receiver E3FA-TP11-D 2M
M12 connector
set E3FA-TN21 set E3FA-TP21
Emitter E3FA-TN21-L
Receiver E3FA-TN21-D
Emitter E3FA-TP21-L
Receiver E3FA-TP21-D
pre-wired
set E3FA-TN12 2M set E3FA-TP12 2M
Emitter E3FA-TN12-L 2M
Receiver E3FA-TN12-D 2M
Emitter E3FA-TP12-L 2M
Receiver E3FA-TP12-D 2M
M12 connector
set E3FA-TN22 set E3FA-TP22
Emitter E3FA-TN22-L
Receiver E3FA-TN22-D
Emitter E3FA-TP22-L
Receiver E3FA-TP22-D
Retro-reflective with MSR
function *2. pre-wired E3FA-RN11 2M E3FA-RP11 2M
M12 connector E3FA-RN21 E3FA-RP21
Coaxial Retro-reflective with
MSR function *2. pre-wired E3FA-RN12 2M E3FA-RP12 2M
M12 connector E3FA-RN22 E3FA-RP22
Diffuse-reflective pre-wired E3FA-DN11 2M E3FA-DP11 2M
M12 connector E3FA-DN21 E3FA-DP21
pre-wired E3FA-DN12 2M E3FA-DP12 2M
M12 connector E3FA-DN22 E3FA-DP22
pre-wired E3FA-DN13 2M E3FA-DP13 2M
M12 connector E3FA-DN23 E3FA-DP23
pre-wired E3FA-DN14 2M E3FA-DP14 2M
M12 connector E3FA-DN24 E3FA-DP24
pre-wired E3FA-DN15 2M E3FA-DP15 2M
M12 connector E3FA-DN25 E3FA-DP25
pre-wired E3FA-DN16 2M E3FA-DP16 2M
M12 connector E3FA-DN26 E3FA-DP26
BGS
(background suppression)
pre-wired E3FA-LN11 2M E3FA-LP11 2M
M12 connector E3FA-LN21 E3FA-LP21
pre-wired E3FA-LN12 2M E3FA-LP12 2M
M12 connector E3FA-LN22 E3FA-LP22
Limited distance reflective pre-wired E3FA-VN11 2M E3FA-VP11 2M
M12 connector E3FA-VN21 E3FA-VP21
Transparent detected with
P-opaquing function *2. pre-wired E3FA-BN11 2M E3FA-BP11 2M
M12 connector E3FA-BN21 E3FA-BP21
Transparent detected with
P-opaquing function *2. pre-wired E3FA-BN12 2M E3FA-BP12 2M
M12 connector E3FA-BN22 E3FA-BP22
Red light Infrared light
20 m
15 m
0.1 to 4 m
with E39-R1S
0 to 500 mm
with E39-R1S
100 mm
300 mm
1 m
100 mm
300 mm
1 m
100 mm
200 mm
3
E3FA/E3RA/E3FB/E3RB
Sensors (E3RA Plastic housing) [Refer to Dimensions on page 16.]
*1. The set type includes the emitter and receiver.
*2. The Reflector is sold separately. Select the Reflector model most suited to the application.
Sensor type Sensing distance Connection method Model
NPN output PNP output
Through-beam *1.
pre-wired
set E3RA-TN11 2M set E3RA-TP11 2M
Emitter E3RA-TN11-L 2M
Receiver E3RA-TN11-D 2M
Emitter E3RA-TP11-L 2M
Receiver E3RA-TP11-D 2M
M12 connector
set E3RA-TN21 set E3RA-TP21
Emitter E3RA-TN21-L
Receiver E3RA-TN21-D
Emitter E3RA-TP21-L
Receiver E3RA-TP21-D
Retro-reflective with MSR
function *2. pre-wired E3RA-RN11 2M E3RA-RP11 2M
M12 connector E3RA-RN21 E3RA-RP21
Diffuse-reflective pre-wired E3RA-DN11 2M E3RA-DP11 2M
M12 connector E3RA-DN21 E3RA-DP21
pre-wired E3RA-DN12 2M E3RA-DP12 2M
M12 connector E3RA-DN22 E3RA-DP22
pre-wired E3RA-DN13 2M E3RA-DP13 2M
M12 connector E3RA-DN23 E3RA-DP23
Red light
15 m
100 mm
300 mm
700 mm
4
E3FA/E3RA/E3FB/E3RB
Sensors (E3FB/E3RB Metal housing) [Refer to Dimensions on page 17.]
*1. The set type includes the emitter and receiver.
*2. The Reflector is sold separately. Select the Reflector model most suited to the application.
Sensor type Sensing distance Connection method Model
NPN output PNP output
Through-beam *1.
pre-wired
set E3FB-TN11 2M set E3FB-TP11 2M
Emitter E3FB-TN11-L 2M
Receiver E3FB-TN11-D 2M
Emitter E3FB-TP11-L 2M
Receiver E3FB-TP11-D 2M
M12 connector
set E3FB-TN21 set E3FB-TP21
Emitter E3FB-TN21-L
Receiver E3FB-TN21-D
Emitter E3FB-TP21-L
Receiver E3FB-TP21-D
Retro-reflective with MSR
function *2. pre-wired E3FB-RN11 2M E3FB-RP11 2M
M12 connector E3FB-RN21 E3FB-RP21
Coaxial Retro-reflective with
MSR function *2. pre-wired E3FB-RN12 2M E3FB-RP12 2M
M12 connector E3FB-RN22 E3FB-RP22
Diffuse-reflective pre-wired E3FB-DN11 2M E3FB-DP11 2M
M12 connector E3FB-DN21 E3FB-DP21
pre-wired E3FB-DN12 2M E3FB-DP12 2M
M12 connector E3FB-DN22 E3FB-DP22
pre-wired E3FB-DN13 2M E3FB-DP13 2M
M12 connector E3FB-DN23 E3FB-DP23
BGS
(background suppression)
pre-wired E3FB-LN11 2M E3FB-LP11 2M
M12 connector E3FB-LN21 E3FB-LP21
pre-wired E3FB-LN12 2M E3FB-LP12 2M
M12 connector E3FB-LN22 E3FB-LP22
Limited distance reflective pre-wired E3FB-VN11 2M E3FB-VP11 2M
M12 connector E3FB-VN21 E3FB-VP21
Transparent detected with
P-opaquing function *2. pre-wired E3FB-BN11 2M E3FB-BP11 2M
M12 connector E3FB-BN21 E3FB-BP21
Transparent detected with
P-opaquing function *2. pre-wired E3FB-BN12 2M E3FB-BP12 2M
M12 connector E3FB-BN22 E3FB-BP22
Through-beam *1.
pre-wired
set E3RB-TN11 2M set E3RB-TP11 2M
Emitter E3RB-TN11-L 2M
Receiver E3RB-TN11-D 2M
Emitter E3RB-TP11-L 2M
Receiver E3RB-TP11-D 2M
M12 connector
set E3RB-TN21 set E3RB-TP21
Emitter E3RB-TN21-L
Receiver E3RB-TN21-D
Emitter E3RB-TP21-L
Receiver E3RB-TP21-D
Retro-reflective with MSR
function *2. pre-wired E3RB-RN11 2M E3RB-RP11 2M
M12 connector E3RB-RN21 E3RB-RP21
Diffuse-reflective pre-wired E3RB-DN11 2M E3RB-DP11 2M
M12 connector E3RB-DN21 E3RB-DP21
pre-wired E3RB-DN12 2M E3RB-DP12 2M
M12 connector E3RB-DN22 E3RB-DP22
pre-wired E3RB-DN13 2M E3RB-DP13 2M
M12 connector E3RB-DN23 E3RB-DP23
Red light
20 m
0.1 to 4 m
with E39-R1S
0 to 500 mm
with E39-R1S
100 mm
300 mm
1 m
100 mm
200 mm
10 to 50 mm
100 to 500 mm
with E39-RP1
0.1 to 2 m
with E39-RP1
15 m
0.1 to 3 m
with E39-R1S
100 mm
300 mm
700 mm
5
E3FA/E3RA/E3FB/E3RB
Reflectors [Refer to Dimensions on page 18.]
Reflectors required for Retro-reflective Sensors: A Reflector is not provided with the Sensor. Be sure to order a Reflector separately.
Mounting brackets [Refer to Dimensions on page 18.]
A Mounting Bracket is not enclosed with the Sensor. Order a Mounting Bracket separately if required.
Sensor I/O connectors
Models for Connectors: A Connector is not provided with the Sensor. Be sure to order a Connector separately.
Model Number Legend
E3@-@@@@-(@)@
–– ––
12345 67
1. Series name
FA: Cylindrical, Straight type, Plastic housing
RA: Cylindrical, Radial type, Plastic housing
FB: Cylindrical, Straight type, Metal housing
RB: Cylindrical, Radial type, Metal housing
2. Sensing method
T: Through-beam
R: Retro-reflective with MSR function
D: Diffuse-reflective
L: Background suppression
V: Limited distance reflective
B: Transparent detected with P-opaquing function
3. Output
P: PNP
N: NPN
4. Connection
1: Cable
2: Connector, M12, 4-pin
5. Difference of sensing distance, difference of light source
Sequential number
6. Emitter/Receiver
D: Receiver
L: Emitter
7. Cable length
Blank: Connector type
e.g., E3FA-TP11 2M;
Cylindrical, Straight type, Plastic housing/ Through-beam/ PNP/
Cable/ Difference of Sensing distance/ Cable length of 2M
E3RA-TN12-D;
Cylindrical, Radial type, Plastic housing/ Through-beam/ NPN/
Connector, M12, 4-pin/ Difference of Sensing distance/
Receiver/ Connector type
E3FA-VP12;
Cylindrical, Straight type, Plastic housing/ Limited distance
reflective/ PNP/ Connector, M12, 4-pin/ Difference of Sensing
distance/ Connector type
Sensor Sensing distance Appearance Model Quantity Remarks
E3FA-R@1
E3FB-R@10.1 to 4 m
E39-R1S 1for E3FA-R@, E3RA-R@,
E3FB-R@ and E3RB-R@
E3FA-R@2
E3FB-R@20 to 500 mm
E3FA-B@1
E3FB-B@1100 to 500 mm
E39-RP1 1for E3FA-B@ and E3FB-B@
E3FA-B@2
E3FB-B@20.1 to 2 m
Sensor Appearance Model (Material) Quantity Remarks
all types E39-L183 (SUS304) 1 Mounting bracket
E3FA-@
E3RA-@E39-L182 (POM) 1 Flush mounting bracket
Sensor Size Cable Appearance Cable type Model
M12 connector types M12 Standard
2 m
4-wire
XS2F-M12PVC4S2M
5 m XS2F-M12PVC4S5M
2 m XS2F-M12PVC4A2M
5 m XS2F-M12PVC4A5M
Straight
Angle
E3FA/E3RA/E3FB/E3RB
6
Ratings and Specifications
Straight type (E3FA/E3FB)
* IP69K Degree of Protection Specifications
IP69K is a protection specification stipulated by DIN 40050 Part 9 of the German standards.
The test item is sprayed with 80C water from a nozzle of a specified shape at a water pressure of 80 to 100 bar. The amount of water
is 14 to 16 liters per minute.
The distance between the test item and the nozzle is 10 to 15 cm. The water is discharged at angles of 0, 30, 60, and 90 from
the horizontal plane for 30 seconds at each angle while the test item is rotated horizontally.
Sensing method Through-beam Retro-reflective with
MSR function
Coaxial Retro-reflective
with MSR function
Model NPN
output
Pre-wired E3F@-TN11 2M E3FA-TN12 2M E3F@-RN11 2M E3F@-RN12 2M
M12 Connector
E3F@-TN21 E3FA-TN22 E3F@-RN21 E3F@-RN22
PNP
output
Pre-wired E3F@-TP11 2M E3FA-TP12 2M E3F@-RP11 2M E3F@-RP12 2M
Item
M12 Connector
E3F@-TP21 E3FA-TP22 E3F@-RP21 E3F@-RP22
Sensing distance 20 m 15 m 0.1 to 4 m
(with E39-R1S)
0 to 500 mm
(with E39-R1S)
Spot diameter (reference value)
Standard sensing object Opaque: 7 mm dia.min. Opaque: 75 mm dia.min.
Differential travel
Directional angle 2 min.
Light source (wavelength) Red LED (624 nm) Infrared LED (850 nm) Red LED (624 nm)
Power supply voltage 10 to 30 VDC (include voltage ripple of 10%(p-p) max.)
Current consumption 40 mA max.
(Emitter 25 mA max. Receiver 15 mA max.) 25 mA max.
Control output NPN/PNP (open collector)
Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage: 30 VDC max.
Operation mode Light-ON/Dark-ON selectable by wiring
Indicator
Operation indicator (orange)
Stability indicator (green)
Power indicator (green): only Emitter of Through-beam
Protection circuits
Power supply reverse polarity protection, Output short-circuit protection, and Output reverse polarity protection
Response time 0.5 ms
Sensitivity adjustment One-turn adjuster
Ambient illumination (Receiver side)
Incandescent lamp: 3,000 lx max./ Sunlight: 10,000 lx max.
Ambient temperature range Operating: -25 to 55C/ Storage: -30 to 70C (with no icing or condensation)
Ambient humidity range Operating: 35 to 85%/ Storage: 35 to 95% (with no condensation)
Insulation resistance 20 M min. at 500 VDC
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min. between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance Destruction: 500 m/s2 3 times each in X, Y and Z directions
Degree of protection IEC: IP67, DIN 40050-9: IP69K *
Weight
(packed
state/only
sensor)
Pre-wired cable (2M) E3FA: Approx. 110 g/ Approx. 50 g, respectively,
E3FB: Approx. 175 g/ Approx. 65 g, respectively
E3FA: Approx. 60 g/ Approx. 50 g,
E3FB: Approx. 95 g/ Approx. 65 g
Connector E3FA: Approx. 30 g/ Approx. 10 g, respectively,
E3FB: Approx. 85 g/ Approx. 20 g, respectively
E3FA: Approx. 20 g/ Approx. 10 g,
E3FB: Approx. 50 g/ Approx. 20 g
Material
Case E3FA: ABS, E3FB: Nickel-brass
Lens and Display PMMA
Adjuster POM
Nut E3FA: POM, E3FB: Nickel-brass
Accessories Instruction sheet
M18 nuts (4 pcs)
Instruction sheet
M18 nuts (2 pcs)
7
E3FA/E3RA/E3FB/E3RB
Straight type (E3FA/E3FB)
* IP69K Degree of Protection Specifications
IP69K is a protection specification stipulated by DIN 40050 Part 9 of the German standards.
The test item is sprayed with 80C water from a nozzle of a specified shape at a water pressure of 80 to 100 bar. The amount of water
is 14 to 16 liters per minute.
The distance between the test item and the nozzle is 10 to 15 cm. The water is discharged at angles of 0, 30, 60, and 90 from
the horizontal plane for 30 seconds at each angle while the test item is rotated horizontally.
Sensing method Diffuse-reflective
Model NPN
output
Pre-wired
E3F
@
-DN11 2M E3F
@
-DN12 2M E3F
@
-DN13 2M E3FA-DN14 2M E3FA-DN15 2M E3FA-DN16 2M
M12 Connector
E3F@-DN21 E3F@-DN22 E3F@-DN23 E3F
A
-DN24 E3F
A
-DN25 E3F
A
-DN26
PNP
output
Pre-wired
E3F
@
-DP11 2M E3F
@
-DP12 2M E3F
@
-DP13 2M E3FA-DP14 2M E3FA-DP15 2M E3FA-DP16 2M
Item
M12 Connector
E3F@-DP21 E3F@-DP22 E3F@-DP23 E3F
A
-DP24 E3F
A
-DP25 E3F
A
-DP26
Sensing distance
100 mm
(white paper:
300 300 mm)
300 mm
(white paper:
300 300 mm)
1 m
(white paper:
300 300 mm)
100 mm
(white paper:
300 300 mm)
300 mm
(white paper:
300 300 mm)
1 m
(white paper:
300 300 mm)
Spot diameter (reference value)
40
45 mm
Sensing distance
of 100 mm
40
50 mm
Sensing distance
of 300 mm
120
150 mm
Sensing distance
of 1 m
40
45 mm
Sensing distance
of 100 mm
40
50 mm
Sensing distance
of 300 mm
120
150 mm
Sensing distance
of 1 m
Standard sensing object
Differential travel 20% max.
Directional angle
Light source (wavelength) Red LED (624 nm) Infrared LED (850 nm)
Power supply voltage 10 to 30 VDC (include voltage ripple of 10%(p-p) max.)
Current consumption 25 mA max.
Control output NPN/PNP (open collector)
Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage: 30 VDC max.
Operation mode Light-ON/Dark-ON selectable by wiring
Indicator Operation indicator (orange)
Stability indicator (green)
Protection circuits
Power supply reverse polarity protection, Output short-circuit protection, and Output reverse polarity protection
Response time 0.5 ms
Sensitivity adjustment One-turn adjuster
Ambient illumination (Receiver side)
Incandescent lamp: 3,000 lx max./ Sunlight: 10,000 lx max.
Ambient temperature range Operating: -25 to 55C/ Storage: -30 to 70C (with no icing or condensation)
Ambient humidity range Operating: 35 to 85%/ Storage: 35 to 95% (with no condensation)
Insulation resistance 20 M min. at 500 VDC
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min. between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance Destruction: 500 m/s2 3 times each in X, Y and Z directions
Degree of protection IEC: IP67, DIN 40050-9: IP69K *
Weight
(packed
state/only
sensor)
Pre-wired cable (2M) E3FA: Approx. 60 g/ Approx. 50 g,
E3FB: Approx. 95 g/ Approx. 65 g
Connector E3FA: Approx. 20 g/ Approx. 10 g,
E3FB: Approx. 50 g/ Approx. 20 g
Material
Case E3FA: ABS, E3FB: Nickel-brass
Lens and Display PMMA
Adjuster POM
Nut E3FA: POM, E3FB: Nickel-brass
Accessories Instruction sheet
M18 nuts (2 pcs)
E3FA/E3RA/E3FB/E3RB
8
Straight type (E3FA/E3FB)
* IP69K Degree of Protection Specifications
IP69K is a protection specification stipulated by DIN 40050 Part 9 of the German standards.
The test item is sprayed with 80C water from a nozzle of a specified shape at a water pressure of 80 to 100 bar. The amount of water
is 14 to 16 liters per minute.
The distance between the test item and the nozzle is 10 to 15 cm. The water is discharged at angles of 0, 30, 60, and 90 from
the horizontal plane for 30 seconds at each angle while the test item is rotated horizontally.
Sensing method BGS (Background suppression) Limited distance
reflective
Transparent detected with
P-opaquing function
Model NPN
output
Pre-wired E3F@-LN11 2M E3F@-LN12 2M E3F@-VN11 2M E3F@-BN11 2M E3F@-BN12 2M
M12 Connector
E3F@-LN21 E3F@-LN22 E3F@-VN21 E3F@-BN21 E3F@-BN22
PNP
output
Pre-wired E3F@-LP11 2M E3F@-LP12 2M E3F@-VP11 2M E3F@-BP11 2M E3F@-BP12 2M
Item
M12 Connector
E3F@-LP21 E3F@-LP22 E3F@-VP21 E3F@-BP21 E3F@-BP22
Sensing distance
100 mm
(white paper:
300 300 mm)
200 mm
(white paper:
300 300 mm)
10 to 50 mm
(glass(t = 1.0 mm):
150 150 mm)
100 to 500 mm
(with E39-RP1)
0.1 to 2 m
(with E39-RP1)
Spot diameter (reference value)
10 10 mm
Sensing distance of
100 mm
10 15 mm
Sensing distance of
200 mm
10 10 mm
Sensing distance of
50 mm
Standard sensing object glass(t = 1.0 mm): 150 150 mm
Differential travel 20% max.
Directional angle
Light source (wavelength) Red LED (624 nm)
Power supply voltage 10 to 30 VDC (include voltage ripple of 10%(p-p) max.)
Current consumption 25 mA max.
Control output NPN/PNP (open collector)
Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage: 30 VDC max.
Operation mode Light-ON/Dark-ON selectable by wiring
Indicator Operation indicator (orange)
Stability indicator (green)
Protection circuits
Power supply reverse polarity protection, Output short-circuit protection, and Output reverse polarity protection
Response time 0.5 ms
Sensitivity adjustment Fixed One-turn adjuster
Ambient illumination
(Receiver side) Incandescent lamp: 3,000 lx max./ Sunlight: 10,000 lx max.
Ambient temperature range Operating: -25 to 55C/ Storage: -30 to 70C (with no icing or condensation)
Ambient humidity range Operating: 35 to 85%/ Storage: 35 to 95% (with no condensation)
Insulation resistance 20 M min. at 500 VDC
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min. between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance Destruction: 500 m/s2 3 times each in X, Y and Z directions
Degree of protection IEC: IP67, DIN 40050-9: IP69K *
Weight
(packed
state/only
sensor)
Pre-wired cable (2M) E3FA: Approx. 60 g/ Approx. 50 g,
E3FB: Approx. 95 g/ Approx. 65 g
Connector E3FA: Approx. 20 g/ Approx. 10 g,
E3FB: Approx. 50 g/ Approx. 20 g
Material
Case E3FA: ABS, E3FB: Nickel-brass
Lens and Display PMMA
Adjuster POM
Nut E3FA: POM, E3FB: Nickel-brass
Accessories Instruction sheet
M18 nuts (2 pcs)
9
E3FA/E3RA/E3FB/E3RB
Radial type (E3FA/E3FB)
* IP69K Degree of Protection Specifications
IP69K is a protection specification stipulated by DIN 40050 Part 9 of the German standards.
The test item is sprayed with 80C water from a nozzle of a specified shape at a water pressure of 80 to 100 bar. The amount of water
is 14 to 16 liters per minute.
The distance between the test item and the nozzle is 10 to 15 cm. The water is discharged at angles of 0, 30, 60, and 90 from
the horizontal plane for 30 seconds at each angle while the test item is rotated horizontally.
Sensing method Through-beam Retro-reflective
with MSR function Diffuse-reflective
Model NPN
output
Pre-wired E3R@-TN11 2M E3R@-RN11 2M E3R@-DN11 2M E3R@-DN12 2M E3R@-DN13 2M
M12 Connector
E3R@-TN21 E3R@-RN21 E3R@-DN21 E3R@-DN22 E3R@-DN23
PNP
output
Pre-wired E3R@-TP11 2M E3R@-RP11 2M E3R@-DP11 2M E3R@-DP12 2M E3R@-DP13 2M
Item
M12 Connector
E3R@-TP21 E3R@-RP21 E3R@-DP21 E3R@-DP22 E3R@-DP23
Sensing distance 15 m 0.1 to 3 m
(with E39-R1S)
100 mm
(white paper:
300 300 mm)
300 mm
(white paper:
300 300 mm)
700 mm
(white paper:
300 300 mm)
Spot diameter (reference value)
35 40 mm
Sensing distance
of 100 mm
40 45 mm
Sensing distance
of 300 mm
90 120 mm
Sensing distance
of 700 mm
Standard sensing object Opaque:
7 mm dia.min.
Opaque:
75 mm dia.min.
Differential travel 20% max.
Directional angle 2 min.
Light source (wavelength) Red LED (624 nm)
Power supply voltage 10 to 30 VDC (include voltage ripple of 10%(p-p) max.)
Current consumption
40mA max.
(Emitter 25 mA
max. Receiver 15
mA max.)
25 mA max.
Control output NPN/PNP (open collector)
Load current: 100 mA max. (Residual voltage: 2 V max.), Load power supply voltage: 30 VDC max.
Operation mode Light-ON/Dark-ON selectable by wiring
Indicator
Operation indicator (orange)
Stability indicator (green)
Power indicator (green): only Emitter of Through-beam
Protection circuits
Power supply reverse polarity protection, Output short-circuit protection, and Output reverse polarity protection
Response time 0.5 ms
Sensitivity adjustment One-turn adjuster
Ambient illumination
(Receiver side) Incandescent lamp: 3,000 lx max./ Sunlight: 10,000 lx max.
Ambient temperature range Operating: -25 to 55C/ Storage: -30 to 70C (with no icing or condensation)
Ambient humidity range Operating: 35 to 85%/ Storage: 35 to 95% (with no condensation)
Insulation resistance 20 M min. at 500 VDC
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min. between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance Destruction: 500 m/s2 3 times each in X, Y and Z directions
Degree of protection IEC: IP67, DIN 40050-9: IP69K *
Weight
(packed
state/only
sensor)
Pre-wired cable (2M)
E3RA:
Approx. 110 g/
Approx. 50 g,
respectively,
E3RB:
Approx. 175 g/
Approx. 65 g,
respectively
E3RA: Approx. 60 g/ Approx. 50 g,
E3RB: Approx. 95 g/ Approx. 65 g
Connector
E3RA:
Approx. 30 g/
Approx. 10 g,
respectively,
E3RB:
Approx. 85 g/
Approx. 20 g,
respectively
E3RA: Approx. 20 g/ Approx. 10 g,
E3RB: Approx. 50 g/ Approx. 20 g
Material
Case E3RA: ABS, E3RB: Nickel-brass
Lens and Display PMMA
Adjuster POM
Nut E3RA: POM, E3RB: Nickel-brass
Accessories Instruction sheet
M18 nuts (4 pcs)
Instruction sheet
M18 nuts (2 pcs)
E3FA/E3RA/E3FB/E3RB
10
Engineering Data (Reference Value)
Parallel Operating Range
Through-beam Models Retro-reflective Models (with MSR function)
E3F@-T@, E3R@-T@E3F@-R@1, E3R@-R@1E3F@-R@2
Transparent detected with P-opaquing function
E3F@-B@1E3F@-B@2
Operating Range
Diffuse-reflective Models
E3F@-D@1, E3F@-D@2E3F@-D@3, E3R@-D@3E3FA-D@4, E3FA-D@5
E3R@-D@1, E3R@-D@2
BGS Models Limited distance reflective
E3FA-D@6E3F@-L@1, E3F@-L@2E3F@-V@
Distance Y (mm)
Distance X (m)
405 1015202530350
1000
800
600
400
200
200
0
400
600
800
1000
E3F@-T@@1
E3R@-T@@1
Y
X
E3FA-T@@2
Distance Y (mm)
Distance X (m)
200
200 82460
150
50
50
100
0
100
150
E3F@-R@@1
E3R@-R@@1
Reflector: E39-R1S
Y
X
Distance Y (mm)
Distance X (m)
40
40 1.50.5 10
30
10
10
20
0
20
30
Reflector: E39-R1S
Y
X
Distance Y (mm)
Distance X (mm)
40
40 1200200 400 600 800 10000
30
10
10
20
0
20
30
Reflector: E39-RP1
Y
X
Distance Y (mm)
Distance X (mm)
150
150 4500500 1000 1500 2000 2500 3000 3500 40000
100
50
50
0
100
Reflector: E39-RP1
Y
X
30
30 600100 200 300 400 5000
10
10
20
0
20
Distance Y (mm)
Distance X (mm)
Sensing object: white paper
Y
X
E3F@-D@@2
E3R@-D@@2
E3F@-D@@1
E3R@-D@@1
Distance Y (mm)
Distance X (mm)
100
100 1800200 400 600 800 1000 1200 1400 16000
80
20
40
40
20
60
0
60
80
E3R@-D@@3
E3F@-D@@3
Sensing object: 300 × 300 (mm) white paper
Y
X
Distance Y (mm)
Distance X (mm)
100
100 700100 200 300 400 500 6000
80
20
40
40
20
60
0
60
80
E3FA-D@@5
E3FA-D@@4
Sensing object: white paper
Y
X
Distance Y (mm)
Distance X (mm)
100
100 1600200 400 600 800 1000 1200 14000
80
20
40
40
20
60
0
60
80
Sensing object: 300 × 300 (mm) white paper
Y
X
Distance Z (mm)
Distance X (mm)
40
40 25010050 150 2000
30
10
10
20
0
20
30
E3F@-L@1
E3F@-L@2
Sensing object: white paper
Z
X
Distance Y (mm)
Distance X (mm)
10
10 6020 400
4
4
8
2
6
0
8
2
6
Sensing object: glass (t=1.0 mm)
Y
X
11
E3FA/E3RA/E3FB/E3RB
Excess Gain vs. Distance
Through-beam Models Retro-reflective Models (with MSR function)
E3F@-T@, E3R@-T@E3F@-R@1, E3R@-R@1E3F@-R@2
Diffuse-reflective Models
E3F@-D@1, E3F@-D@2E3F@-D@3, E3R@-D@3E3FA-D@4, E3FA-D@5
E3R@-D@1, E3R@-D@2
Transparent detected with P-opaquing function
Limited distance reflective
E3FA-D@6E3F@-B@1, E3F@-B@2E3F@-V@
Sensing Object Size vs. Distance
Diffuse-reflective Models
E3F@-D@1, E3F@-D@2E3F@-D@3, E3R@-D@3
E3R@-D@1, E3R@-D@2
100
70
50
30
10
7
5
3
1
0.7
0.5
0.3
0.10 10203040506070
Excess gain ratio (multiple)
Distance (m)
Operating
level
E3F@-T@@1
E3R@-T@@1
E3FA-T@@2
100
70
50
30
10
7
5
3
1
0.7
0.5
0.3
0.102 46810
Excess gain ratio (multiple)
Distance (m)
Operating
level
E3F@-R@@1
E3R@-R@@1
Reflector: E39-R1S 100
70
50
30
10
7
5
3
1
0.7
0.5
0.3
0.10 0.5 1 1.5 2
Excess gain ratio (multiple)
Distance (m)
Operating
level
Reflector: E39-R1S
100
70
50
30
10
7
5
3
1
0.7
0.5
0.3
0.10 200 400 600 800 1000
Excess gain ratio (multiple)
Distance (mm)
Operating
level
E3F@-D@@2
E3R@-D@@2
E3F@-D@@1
E3R@-D@@1
Sensing object: 100 × 100 (mm) white paper
100
70
50
30
10
7
5
3
1
0.7
0.5
0.3
0.10 0.5 1 1.5 2 2.5 3
Excess gain ratio (multiple)
Distance (m)
Operating
level
E3F@-D@@3
E3R@-D@@3
Sensing object: 300 × 300 (mm) white paper
100
70
50
30
10
7
5
3
1
0.7
0.5
0.3
0.10 200 400 600 800 1000
Excess gain ratio (multiple)
Distance (mm)
Operating
level
E3FA-D@@5
E3FA-D@@4
Sensing object: 300 × 300 (mm) white paper
100
70
50
30
10
7
5
3
1
0.7
0.5
0.3
0.10 0.5 1 1.5 2 2.5 3
Excess gain ratio (multiple)
Distance (m)
Operating
level
Sensing object: 300 × 300 (mm) white paper
100
70
50
30
10
7
5
3
1
0.7
0.5
0.3
0.101 234
Excess gain ratio (multiple)
Distance (m)
Operating
level
E3F@-B@1
E3F@-B@2
Reflector: E39-RP1 100
70
50
30
10
7
5
3
1
0.7
0.5
0.3
0.10 10203040506070
Excess gain ratio (multiple)
Distance (mm)
Operating
level
Sensing object: glass (t=1.0 mm)
30050 150 250100 200
Length d of sensing object (mm)
600
500
400
300
200
100
700
0
0
Distance (mm)
E3F@-D@@1
E3R@-D@@1
E3F@-D@@2
E3R@-D@@2
d
d
Sensing object: White paper
1800
1600
1400
1200
1000
600
800
400
200
2000
0
50050 150 250 350 450100 200 300 4000
Length d of sensing object (mm)
Distance (mm)
E3F@-D@@3
E3R@-D@@3
d
d
Sensing object: White paper
E3FA/E3RA/E3FB/E3RB
12
E3FA-D@4, E3FA-D@5E3FA-D@6
Sensing Distance vs. Sensing Object Material
BGS Models
E3F@-L@1E3F@-L@2
Dark Excess Gain vs. Sensing Object Characteristics
Transparent detected with P-opaquing function
E3F@-B@1E3F@-B@2
Object Surface Color vs. Sensing Distance
Diffuse-reflective Models
E3FA-D@4E3FA-D@5E3FA-D@6
30050 150 250100 200
Length d of sensing object (mm)
800
600
700
500
400
300
200
100
1000
900
0
0
Distance (mm)
E3FA-D@4
E3FA-D@5
d
d
Sensing object: White paper
30050 150 250100 200
Length d of sensing object (mm)
1200
800
1000
600
400
200
1600
1400
0
0
Distance (mm)
d
d
Sensing object: White paper
120
100
80
60
40
20
0
Material
Sensing distance (mm)
White paper SUSBlack paper
250
200
150
100
50
0
Material
Sensing distance (mm)
White paper SUSBlack paper
2.5
2.0
1.5
1.0
0.5
0.0
Relative amount of light received
No sensing
object
Round, 500-ml
PET bottle
Square,500-ml
PET bottle
Filled with
water
Filled with
water
EmptyEmpty
250 mm
500 mm
Operating
level
2.5
2.0
1.5
1.0
0.5
0.0
Relative amount of light received
No sensing
object
Round, 500-ml
PET bottle
Square,500-ml
PET bottle
Filled with
water
Filled with
water
EmptyEmpty
1 m
2 m
Operating
level
180
140
100
60
20
160
120
80
40
0
Sensing distance (mm)
Black
paper
Blue
paper
Green
paper
Red
paper
White
paper
0
Sensing distance (mm)
Black
paper
Blue
paper
Green
paper
Red
paper
White
paper
700
500
300
100
600
400
200
0
Sensing distance (mm)
Black
paper
Blue
paper
Green
paper
Red
paper
White
paper
1600
1400
1000
600
200
1200
800
400
13
E3FA/E3RA/E3FB/E3RB
Output circuit diagram
PNP Output
Model Operation
mode Timing charts Operation
selector Output circuit
E3F@-TP@
E3F@-RP@
E3F@-DP@
E3F@-VP@
E3F@-BP@
E3R@-TP@
E3R@-RP@
E3R@-DP@
Light-ON
Connect the
pink wire
(Pin(2)) to the
brown (Pin(1))
Dark-ON
Connect the
pink wire
(Pin(2)) to the
blue (Pin(3))
or open the
pink wire
(Pin(2))
E3F@-LP@
Light-ON
Connect the
pink wire
(Pin(2)) to the
brown (Pin(1))
Dark-ON
Connect the
pink wire
(Pin(2)) to the
blue (Pin(3))
or open the
pink wire
(Pin(2))
Light incident
Light interrupted
ON
OFF
ON
OFF
Operate
Reset
Operation indicator
(orange)
(Between blue
and black leads)
Output transistor
Load
(e.g., relay)
4
3
2
1
Pink
100 mA max.
(Control output)
Light-ON
Dark-ON
0 V
Operation
indicator
(Orange)
Stability
indicator
(Green)
Photo-
electric
Sensor
Main
Circuit
10 to 30 VDC
Brown
Black
Blue
Load
(Relay)
Through-beam Receivers, Retro-reflective Models,
Diffuse-reflective Models, Limited reflective Models.
Transparent detected with P-opaquing function.
Light incident
Light interrupted
ON
OFF
ON
OFF
Operate
Reset
Operation indicator
(orange)
(Between blue
and black leads)
Output transistor
Load
(e.g., relay)
3
1
Through-beam Emitter
Power
indicator
(green)
Photo-
electric
Sensor
Main
Circuit
Brown
Blue
10 to 30 VDC
NEAR FAR
ON
OFF
ON
OFF
Operate
Reset
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
(Between blue
and black leads)
4
3
2
1
Pink
100 mA max.
(Control output)
Light-ON
Dark-ON
0 V
Operation
indicator
(Orange)
Stability
indicator
(Green)
Photo-
electric
Sensor
Main
Circuit
10 to 30 VDC
Brown
Black
Blue
Load
(Relay)
Background suppression.
NEAR FAR
ON
OFF
ON
OFF
Operate
Reset
Operation indicator
(oramge)
Output transistor
Load
(e.g., relay)
(Between blue
and black leads)
E3FA/E3RA/E3FB/E3RB
14
NPN Output
Connector Pin Arrangement
M12 Connector Pin Arrangement
Connectors (Sensor I/O connectors)
M12 4-wire Connectors
Model Operation
mode Timing charts Operation
selector Output circuit
E3F@-TN@
E3F@-RN@
E3F@-DN@
E3F@-VN@
E3F@-BN@
E3R@-TN@
E3R@-RN@
E3R@-DN@
Light-ON
Connect the
pink wire
(Pin(2)) to the
brown (Pin(1))
or open the
pink wire
(Pin(2))
Dark-ON
Connect the
pink wire
(Pin(2)) to the
blue (Pin(3))
E3F@-LN@
Light-ON
Connect the
pink wire
(Pin(2)) to the
brown (Pin(1))
or open the
pink wire
(Pin(2))
Dark-ON
Connect the
pink wire
(Pin(2)) to the
blue (Pin(3))
Light incident
Light interrupted
ON
OFF
ON
OFF
Operate
Reset
Operation indicator
(orange)
(Between brown
and black leads)
Output transistor
Load
(e.g., relay)
4
3
2
110 to 30 VDC
Brown
Black
Blue
Pink
100 mA max.
(Control output)
Light-ON
Dark-ON
Operation
indicator
(Orange)
Stability
indicator
(Green)
0 V
Load
(Relay)
Photo-
electric
Sensor
Main
Circuit
Through-beam Receivers, Retro-reflective Models,
Diffuse-reflective Models, Limited reflective Models.
Transparent detected with P-opaquing function.
Light incident
Light interrupted
ON
OFF
ON
OFF
Operate
Reset
Operation indicator
(orange)
(Between brown
and black leads)
Output transistor
Load
(e.g., relay)
3
1
Through-beam Emitter
Power
indicator
(green)
Photo-
electric
Sensor
Main
Circuit
Brown
Blue
10 to 30 VDC
NEAR FAR
ON
OFF
ON
OFF
Operate
Reset
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
(Between brown
and black leads)
Background suppression.
4
3
2
110 to 30 VDC
Brown
Black
Blue
Pink
100 mA max.
(Control output)
Light-ON
Dark-ON
Operation
indicator
(Orange)
Stability
indicator
(Green)
0 V
Load
(Relay)
Photo-
electric
Sensor
Main
Circuit
NEAR FAR
ON
OFF
ON
OFF
Operate
Reset
Operation indicator
(oramge)
Output transistor
Load
(e.g., relay)
(Between brown
and black leads)
3
1
24
Classification Wire color Connector pin No. Application
DC
Brown Power supply (+V)
White L/on · D/on selectable
Blue Power supply (0 V)
Black Output
2
4
13
1
2
3
4
Brown
Blue
White
Black
Pin No.
Wire color
15
E3FA/E3RA/E3FB/E3RB
Nomenclature
* The Emitter has two Power indicators (Green) instead of the Stability indicator (Green) and the Operation indicator (Orange).
* The Emitter has two Power indicators (Green) instead of the Stability indicator (Green) and the Operation indicator (Orange).
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for directly or
indirectly ensuring safety of persons. Do not use it
for such a purpose.
Never use the product with an AC power supply.
Do not use the product with voltage in excess of the
rated voltage.
Do not use the product with incorrect wiring.
Otherwise, explosion, fire, malfunction may result.
Be sure to follow the safety precautions below for added safety.
1. Do not use the sensor under the environment with explosive,
flammable or corrosive gas.
2. Do not use the sensor under the oil or chemical environment.
3. Do not use the sensor in the water, rain or outdoors.
4. Do not use the sensor in the environment where humidity is high
and condensation may occur.
5. Do not use the sensor under the environment under the other
conditions in excess of rated.
6. Do not use the sensor in place that is exposed by direct sunlight.
7. Do not use the sensor in place where the sensor may receive
direct vibration or shock.
8. Do not use the thinner, alcohol, or other organic solvents.
9. Never disassemble, repair nor tamper with the sensor.
10.Please process it as industrial waste.
1. Laying Sensor wiring in the same conduit or duct as high-voltage
wires or power lines may result in malfunction or damage due to
conduit or use shielded cable.
2. Do not pull on the cable with excessive force.
3. If a commercial switching regulator is used, ground the FG (frame
ground) terminal.
4. The sensor will be available 100 ms after the power supply is tuned
ON. Start to use the sensor 100 ms or more after turning ON the
power supply. If the load and the sensor are connected to separate
power supplies, be sure to turn ON the sensor first.
5. Output pulses may be generated even when the power supply is
OFF. Therefore, it is recommended to first turn OFF the power
supply for the load or the load line.
6. The sensor must be mounted using the provided nuts. The proper
tightening torque range of E3FA/E3RA plastic housing series is
between 0.4 and 0.5 N°m. The proper tightening torque of E3FB/
E3RB metal housing series is 20 N°m max..
Stability indicator
(Green)
Operation indicator
(Orange)
Sensitivity adjuster
Straight type, Plastic housing
with an adjuster:
E3FA-T@-D
E3FA-R@
E3FA-D@
E3FA-V@
E3FA-B@
without an adjuster:
E3FA-T@-L *
E3FA-L@
Stability indicator
(Green)
Operation indicator
(Orange)
Sensitivity adjuster
Radial type, Plastic housing
with an adjuster:
E3RA-T@-D
E3RA-R@
E3RA-D@
without an adjuster:
E3RA-T@-L *
Stability indicator
(Green)
Operation indicator
(Orange)
Sensitivity adjuster
Straight type, Metal housing
with an adjuster:
E3FB-T@-D
E3FB-R@
E3FB-D@
E3FB-V@
E3FB-B@
without an adjuster:
E3FB-T@-L *
E3FB-L@
Stability indicator
(Green)
Operation indicator
(Orange)
Sensitivity adjuster
Radial type, Metal housing
with an adjuster:
E3RB-T@-D
E3RB-R@
E3RB-D@
without an adjuster:
E3RB-T@-L *
WARNING
CAUTION
Precautions for Safe Use
Precautions for Correct Use
E3FA/E3RA/E3FB/E3RB
16
Dimensions
Sensors (E3FA/E3RA Plastic housing)
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
2
M18 × 30.5 P=1
Operation indicator (orange)
Sensitivity adjuster *
7 dia.
18.5 dia.
+0.5
0
Stability indicator (green)
Vinyl insulated round cable 4 dia. 4 cores
(conductor cross sectional area:0.128 mm2 (AWG26)
/insulation outside diameter:0.85 dia.)
standard length 2 m
Receiver
Emitter
Optical axisOptical axis
34.5
23
30.5
41
15 15
16.6 dia.
7
E3FA series
Pre-wired Models
E3FA-T@1@
E3FA-R@1@
E3FA-D@1@
E3FA-L@1@
E3FA-V@11
E3FA-B@1@
Suitable models
E3FA-T@1@
E3FA-R@12
E3FA-B@11
Suitable models
E3FA-R@11
E3FA-D@1@
E3FA-L@1@
E3FA-V@11
E3FA-B@12
* Suitable models
E3FA-T@1@-D
E3FA-R@12
E3FA-D@1@
E3FA-V@11
E3FA-B@12
Mounting HolesLeft side view Left side view
Front view
E3FA series
M12 Connector Models
E3FA-T@2@
E3FA-R@2@
E3FA-D@2@
E3FA-L@2@
E3FA-V@21
E3FA-B@2@
2
M18 × 30.5 P=1
M12 × 4 P=1
7 dia.
18.5 dia.
+0.5
0
34.5
23
30.5
15 15
16.6 dia.
7
1
2
34
Operation indicator (orange)
Sensitivity adjuster *
Stability indicator (green)
Receiver
Emitter
Optical axisOptical axis
45
Suitable models
E3FA-T@2@
E3FA-R@22
E3FA-B@21
Suitable models
E3FA-R@21
E3FA-D@2@
E3FA-L@2@
E3FA-V@21
E3FA-B@22
Mounting Holes
Terminal No. Specification
1+V
2 L/on · D/on selectable
30V
4 Output
* Suitable models
E3FA-T@2@-D
E3FA-R@22
E3FA-D@2@
E3FA-V@21
E3FA-B@22
Left side view Left side view
Front view Right side view
Emitter
ReceiverOptical axis Optical axis M18 × 30.5 P=1
Operation indicator (orange)
Sensitivity adjuster
7 dia.
18.5 dia.
+0.5
0
Stability
indicator (green)
Vinyl insulated round cable 4 dia. 4 cores
(conductor cross sectional area:0.128 mm2 (AWG26)
/insulation outside diameter:0.85 dia.)
standard length 2 m
714.1 dia.
5.2 5.2
14.9
47.4
53.9
43.4
35.9
E3RA series
Pre-wired Models
E3RA-T@11
E3RA-R@11
E3RA-D@1@
Mounting Holes
Suitable models
E3RA-T@11
Suitable models
E3RA-R@11
E3RA-D@1@
Rear view Rear view Front view
M18 × 30.5 P=1
M12 × 4 P=1
7 dia.
18.5 dia.
+0.5
0
714.1 dia.
5.2 5.2
14.9
47.4
57.9
43.4
35.9
1
23
4
Emitter
ReceiverOptical axis Optical axis
Operation indicator (orange)
Sensitivity adjuster
Stability
indicator (green)
E3RA series
M12 Connector Models
E3RA-T@21
E3RA-R@21
E3RA-D@2@
Mounting Holes
Suitable models
E3RA-T@21
Suitable models
E3RA-R@21
E3RA-D@2@
Terminal No. Specification
1+V
2 L/on · D/on selectable
30V
4 Output
Rear view Rear view Front view
Bottom view
17
E3FA/E3RA/E3FB/E3RB
Sensors (E3FB/E3RB Metal housing)
M18 × 26.4 P=1
Operation indicator (orange)
Sensitivity adjuster *
7 dia.
18.5 dia.
+0.5
0
Stability indicator (green)
Vinyl insulated round cable 4 dia. 4 cores
(conductor cross sectional area:0.128 mm2 (AWG26)
/insulation outside diameter:0.85 dia.)
standard length 2 m
Receiver
Emitter
Optical axisOptical axis
37.5
23
29.9
44
7
E3FB series
Pre-wired Models
E3FB-T@11
E3FB-R@1@
E3FB-D@1@
E3FB-L@1@
E3FB-V@11
E3FB-B@1@
Suitable models
E3FB-T@11
E3FB-R@12
E3FB-B@11
Suitable models
E3FB-R@11
E3FB-D@1@
E3FB-L@1@
E3FB-V@11
E3FB-B@12
* Suitable models
E3FB-T@11-D
E3FB-R@12
E3FB-D@1@
E3FB-V@11
E3FB-B@12
Mounting HolesLeft side view Left side view
Front view
E3FB series
M12 Connector Models
E3FB-T@21
E3FB-R@2@
E3FB-D@2@
E3FB-L@2@
E3FB-V@21
E3FB-B@2@
M18 × 26.4 P=1
Operation indicator (orange)
Sensitivity adjuster *
7 dia.
18.5 dia.
+0.5
0
Stability indicator (green)
Receiver
Emitter
Optical axisOptical axis
37.5
23
29.9
48
7
M12 × 4 P=1
1
2
34
Suitable models
E3FB-T@21
E3FB-R@22
E3FB-B@21
Suitable models
E3FB-R@21
E3FB-D@2@
E3FB-L@2@
E3FB-V@21
E3FB-B@22
Mounting Holes
Terminal No. Specification
1+V
2 L/on · D/on selectable
30V
4 Output
* Suitable models
E3FB-T@21-D
E3FB-R@22
E3FB-D@2@
E3FB-V@21
E3FB-B@22
Left side view Left side view
Front view Right side view
Emitter
ReceiverOptical axis Optical axis M18 × 26.4 P=1
Operation indicator (orange)
Sensitivity adjuster
7 dia.
18.5 dia.
+0.5
0
Stability
indicator (green)
Vinyl insulated round cable 4 dia. 4 cores
(conductor cross sectional area:0.128 mm2 (AWG26)
/insulation outside diameter:0.85 dia.)
standard length 2 m
714.1 dia.
5.2 5.2
13
50.4 56.9
42.8
35.9
E3RB series
Pre-wired Models
E3RB-T@11
E3RB-R@11
E3RB-D@1@
Mounting Holes
Suitable models
E3RB-T@11
Suitable models
E3RB-R@11
E3RB-D@1@
Rear view Rear view Front view
Emitter
ReceiverOptical axis Optical axis M18 × 26.4 P=1
Operation indicator (orange)
Sensitivity adjuster
7 dia.
18.5 dia.
+0.5
0
Stability
indicator (green)
714.1 dia.
5.2 5.2
13
50.4
60.9
42.8
35.9
1
23
4
M12 × 4 P=1
E3RB series
M12 Connector Models
E3RB-T@21
E3RB-R@21
E3RB-D@2@
Mounting Holes
Suitable models
E3RB-T@21
Suitable models
E3RB-R@21
E3RB-D@2@
Terminal No. Specification
1+V
2 L/on · D/on selectable
30V
4 Output
Rear view Rear view Front view
Bottom view
E3FA/E3RA/E3FB/E3RB
18
Accessories (Order Separately)
Material:POM(for E3FA/E3RA)
Nickel-brass(for E3FB/E3RB)
Three, 24
24 dia.
M18 4 P=1
4
Attached nut
34
40.3
5259.9
2.7
8
1.6
7.5
7
Two, 3.5 dia.
72 63.680
44
Two, 3.5 dia.
Reflector
3
8.5
0.2
Reflectors
E39-R1S E39-RP1
4.3
37
22
15
36.5
20
Two, 30°
Two, 4.3
Two, R15
42
1.5
90°
(R16.5)
18.2 dia.
14.5
15.1
12.5
16.7 dia.
27 dia.
Mounting brackets
E39-L183
Mounting brackets
E39-L182
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Terms and Conditions of Sale
1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed
part of all quotes, agreements, purchase orders, acknowledgments, price lists,
catalogs, manuals, brochures and other documents, whether electronic or in
writing, relating to the sale of products or services (collectively, the "Products")
by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron
objects to any terms or conditions proposed in Buyer’s purchase order or other
documents which are inconsistent with, or in addition to, these Terms.
2. Prices; Payment Terms. All prices stated are current, subject to change with-
out notice by Omron. Omron reserves the right to increase or decrease prices
on any unshipped portions of outstanding orders. Payments for Products are
due net 30 days unless otherwise stated in the invoice.
3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices
sent to Buyer after deducting transportation charges, taxes and duties, and will
be allowed only if (i) the invoice is paid according to Omron’s payment terms
and (ii) Buyer has no past due amounts.
4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or
the maximum legal rate, whichever is less, on any balance not paid within the
stated terms.
5. Orders. Omron will accept no order less than $200 net billing.
6. Governmental Approvals. Buyer shall be responsible for, and shall bear all
costs involved in, obtaining any government approvals required for the impor-
tation or sale of the Products.
7. Taxes. All taxes, duties and other governmental charges (other than general
real property and income taxes), including any interest or penalties thereon,
imposed directly or indirectly on Omron or required to be collected directly or
indirectly by Omron for the manufacture, production, sale, delivery, importa-
tion, consumption or use of the Products sold hereunder (including customs
duties and sales, excise, use, turnover and license taxes) shall be charged to
and remitted by Buyer to Omron.
8. Financial. If the financial position of Buyer at any time becomes unsatisfactory
to Omron, Omron reserves the right to stop shipments or require satisfactory
security or payment in advance. If Buyer fails to make payment or otherwise
comply with these Terms or any related agreement, Omron may (without liabil-
ity and in addition to other remedies) cancel any unshipped portion of Prod-
ucts sold hereunder and stop any Products in transit until Buyer pays all
amounts, including amounts payable hereunder, whether or not then due,
which are owing to it by Buyer. Buyer shall in any event remain liable for all
unpaid accounts.
9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation
unless Buyer indemnifies Omron against all related costs or expenses.
10. Force Majeure. Omron shall not be liable for any delay or failure in delivery
resulting from causes beyond its control, including earthquakes, fires, floods,
strikes or other labor disputes, shortage of labor or materials, accidents to
machinery, acts of sabotage, riots, delay in or lack of transportation or the
requirements of any government authority.
11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron:
a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship
except in “break down” situations.
b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall
constitute delivery to Buyer;
c. All sales and shipments of Products shall be FOB shipping point (unless oth-
erwise stated in writing by Omron), at which point title and risk of loss shall
pass from Omron to Buyer; provided that Omron shall retain a security inter-
est in the Products until the full purchase price is paid;
d. Delivery and shipping dates are estimates only; and
e. Omron will package Products as it deems proper for protection against nor-
mal handling and extra charges apply to special conditions.
12. Claims. Any claim by Buyer against Omron for shortage or damage to the
Products occurring before delivery to the carrier must be presented in writing
to Omron within 30 days of receipt of shipment and include the original trans-
portation bill signed by the carrier noting that the carrier received the Products
from Omron in the condition claimed.
13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the
Products will be free from defects in materials and workmanship for a period of
twelve months from the date of sale by Omron (or such other period expressed
in writing by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION,
EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-
ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.
BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. Omron further disclaims all warranties and responsibility of
any type for claims or expenses based on infringement by the Products or oth-
erwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obli-
gation hereunder shall be, at Omron’s election, to (i) replace (in the form
originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying
Product, or (iii) repay or credit Buyer an amount equal to the purchase price of
the non-complying Product; provided that in no event shall Omron be responsi-
ble for warranty, repair, indemnity or any other claims or expenses regarding
the Products unless Omron’s analysis confirms that the Products were prop-
erly handled, stored, installed and maintained and not subject to contamina-
tion, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Compa-
nies shall not be liable for the suitability or unsuitability or the results from the
use of Products in combination with any electrical or electronic components,
circuits, system assemblies or any other materials or substances or environ-
ments. Any advice, recommendations or information given orally or in writing,
are not to be construed as an amendment or addition to the above warranty.
See http://www.omron247.com or contact your Omron representative for pub-
lished information.
14. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE
FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual
price of the Product on which liability is asserted.
15. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and
their employees from and against all liabilities, losses, claims, costs and
expenses (including attorney's fees and expenses) related to any claim, inves-
tigation, litigation or proceeding (whether or not Omron is a party) which arises
or is alleged to arise from Buyer's acts or omissions under these Terms or in
any way with respect to the Products. Without limiting the foregoing, Buyer (at
its own expense) shall indemnify and hold harmless Omron and defend or set-
tle any action brought against such Companies to the extent based on a claim
that any Product made to Buyer specifications infringed intellectual property
rights of another party.
16. Property; Confidentiality. Any intellectual property in the Products is the exclu-
sive property of Omron Companies and Buyer shall not attempt to duplicate it
in any way without the written permission of Omron. Notwithstanding any
charges to Buyer for engineering or tooling, all engineering and tooling shall
remain the exclusive property of Omron. All information and materials supplied
by Omron to Buyer relating to the Products are confidential and proprietary,
and Buyer shall limit distribution thereof to its trusted employees and strictly
prevent disclosure to any third party.
17. Export Controls. Buyer shall comply with all applicable laws, regulations and
licenses regarding (i) export of products or information; (iii) sale of products to
“forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of
regulated technology or information.
18. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right
and no course of dealing between Buyer and Omron shall operate as a waiver
of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder
without Omron's written consent. (c) Law. These Terms are governed by the
law of the jurisdiction of the home office of the Omron company from which
Buyer is purchasing the Products (without regard to conflict of law princi-
ples). (d) Amendment. These Terms constitute the entire agreement between
Buyer and Omron relating to the Products, and no provision may be changed
or waived unless in writing signed by the parties. (e) Severability
. If any provi-
sion hereof is rendered ineffective or invalid, such provision shall not invalidate
any other provision. (f) Setoff. Buyer shall have no right to set off any amounts
against the amount owing in respect of this invoice. (g) Definitions. As used
herein, “includingmeans “including without limitation”; and “Omron Compa-
nies” (or similar words) mean Omron Corporation and any direct or indirect
subsidiary or affiliate thereof.
Certain Precautions on Specifications and Use
1. Suitability of Use. Omron Companies shall not be responsible for conformity
with any standards, codes or regulations which apply to the combination of the
Product in the Buyers application or use of the Product. At Buyer’s request,
Omron will provide applicable third party certification documents identifying
ratings and limitations of use which apply to the Product. This information by
itself is not sufficient for a complete determination of the suitability of the Prod-
uct in combination with the end product, machine, system, or other application
or use. Buyer shall be solely responsible for determining appropriateness of
the particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases but the following is a
non-exhaustive list of applications for which particular attention must be given:
(i) Outdoor use, uses involving potential chemical contamination or electrical
interference, or conditions or uses not described in this document.
(ii) Use in consumer products or any use in significant quantities.
(iii) Energy control systems, combustion systems, railroad systems, aviation
systems, medical equipment, amusement machines, vehicles, safety equip-
ment, and installations subject to separate industry or government regulations.
(iv) Systems, machines and equipment that could present a risk to life or prop-
erty. Please know and observe all prohibitions of use applicable to this Prod-
uct.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROP-
ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
2. Programmable Products. Omron Companies shall not be responsible for the
user’s programming of a programmable Product, or any consequence thereof.
3. Performance Data. Data presented in Omron Company websites, catalogs
and other materials is provided as a guide for the user in determining suitabil-
ity and does not constitute a warranty. It may represent the result of Omron’s
test conditions, and the user must correlate it to actual application require-
ments. Actual performance is subject to the Omron’s Warranty and Limitations
of Liability.
4. Change in Specifications. Product specifications and accessories may be
changed at any time based on improvements and other reasons. It is our prac-
tice to change part numbers when published ratings or features are changed,
or when significant construction changes are made. However, some specifica-
tions of the Product may be changed without any notice. When in doubt, spe-
cial part numbers may be assigned to fix or establish key specifications for
your application. Please consult with your Omron’s representative at any time
to confirm actual specifications of purchased Product.
5. Errors and Omissions. Information presented by Omron Companies has been
checked and is believed to be accurate; however, no responsibility is assumed
for clerical, typographical or proofreading errors or omissions.
OMRON CANADA, INC. • HEAD OFFICE
Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com
OMRON ELECTRONICS DE MEXICO • HEAD OFFICE
México DF • 52.
55.59.01.43.00
• 01-800-226-6766 • mela@omron.com
OMRON ELECTRONICS DE MEXICO • SALES OFFICE
Apodaca, N.L. • 52.81.11.56.99.20 • 01-800-226-6766 • mela@omron.com
OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE
São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br
OMRON ARGENTINA • SALES OFFICE
Cono Sur • 54.11.4783.5300
OMRON CHILE • SALES OFFICE
Santiago • 56.9.9917.3920
OTHER OMRON LATIN AMERICA SALES
54.11.4783.5300
Authorized Distributor:
$BU/P&*&  Note: Specifications are subject to change. © 2014 Omron Electronics LLC Printed in U.S.A.
Printed on recycled paper.
Automation Control Systems
• Machine Automation Controllers (MAC) • Programmable Controllers (PLC)
• Operator interfaces (HMI) • Distributed I/O • Software
Drives & Motion Controls
• Servo & AC Drives • Motion Controllers & Encoders
Temperature & Process Controllers
• Single and Multi-loop Controllers
Sensors & Vision
• Proximity Sensors • Photoelectric Sensors • Fiber-Optic Sensors
• Amplified Photomicrosensors • Measurement Sensors
• Ultrasonic Sensors • Vision Sensors
Industrial Components
• RFID/Code Readers • Relays • Pushbuttons & Indicators
• Limit and Basic Switches • Timers • Counters • Metering Devices
• Power Supplies
Safety
• Laser Scanners • Safety Mats • Edges and Bumpers • Programmable Safety
Controllers • Light Curtains • Safety Relays • Safety Interlock Switches
OMRON AUTOMATION AND SAFETY • THE AMERICAS HEADQUARTERS • Hoffman Estates, IL USA847.843.7900800.556.6766www.omron247.com
OMRON EUROPE B.V.
Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands.
+31 (0) 23 568 13 00
www.industrial.omron.eu
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
E3FA-DP26-F2 E3FA-LP11-F2 2M E3FA-DP25-F2 E3FA-DP24-F2 E3FA-DP16-F2 2M E3FA-LP21-F2 E3FA-
DP15-F2 2M E3FA-DP14-F2 2M