For more Information
please call
1-800-Belden1
General Description:
Security & Alarm Cable, Rated-CM, 4-22 AWG stranded bare copper conductors with polyolefin insulation,
PVC jacket
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors AWG Stranding Conductor Material
422 7x30 BC - Bare Copper
Total Number of Conductors: 4
Insulation
Insulation Material:
Insulation Material Wall Thickness (mm)
PP - Polypropylene 0.178
Outer Shield
Outer Shield Material:
Outer Shield Material
Unshielded
Outer Jacket
Outer Jacket Material:
Outer Jacket Material Nom. Wall Thickness (mm)
PVC - Polyvinyl Chloride 0.381
Overall Cable
Overall Cabling Color Code Chart:
Color
Black
Red
White
Green
Overall Nominal Diameter: 3.327 mm
Mechanical Characteristics (Overall)
Operating Temperature Range: -20°C To +75°C
UL Temperature Rating: 75°C
Bulk Cable Weight: 17.858 Kg/Km
Max. Recommended Pulling Tension: 161.914 N
Min. Bend Radius/Minor Axis: 33.020 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CM
NEC Articles: 800
CEC/C(UL) Specification: CM
Page 1 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
5502UG Multi-Conductor - Residential, Light Commercial and Institutional Applications
CEC/C(UL) Specification: CM
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Flame Test
UL Flame Test: UL1685 UL Loading
CSA Flame Test: FT1
Plenum/Non-Plenum
Plenum (Y/N): No
Electrical Characteristics (Overall)
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/m)
65.62
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
53.1522
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Current
2.2 Amps per conductor @ 25°C
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
5502UG U4FC500 152 MT 2.722 KG BEIGE U4F 4 #22 PP FRPVC
5502UG U4FU1000 305 MT 6.350 KG BEIGE U4F 4 #22 PP FRPVC
5502UG 001C500 152 MT 2.722 KG BROWN 4 #22 PP FRPVC
5502UG 001U1000 305 MT 6.350 KG BROWN 4 #22 PP FRPVC
5502UG 003C1000 305 MT 5.443 KG ORANGE 4 #22 PP FRPVC
5502UG 003C500 152 MT 2.722 KG ORANGE 4 #22 PP FRPVC
5502UG 004C1000 305 MT 5.443 KG YELLOW 4 #22 PP FRPVC
5502UG 004C500 152 MT 2.722 KG YELLOW 4 #22 PP FRPVC
5502UG 004U1000 305 MT 6.350 KG YELLOW 4 #22 PP FRPVC
5502UG 005C500 152 MT 2.722 KG GREEN, DARK 4 #22 PP FRPVC
5502UG 006C1000 305 MT 5.443 KG BLUE, LIGHT 4 #22 PP FRPVC
5502UG 006C500 152 MT 2.722 KG BLUE, LIGHT 4 #22 PP FRPVC
5502UG 006U1000 305 MT 6.350 KG BLUE, LIGHT 4 #22 PP FRPVC
5502UG 007C1000 305 MT 5.443 KG VIOLET 4 #22 PP FRPVC
5502UG 007C500 152 MT 2.722 KG VIOLET 4 #22 PP FRPVC
5502UG 007U1000 305 MT 6.350 KG VIOLET 4 #22 PP FRPVC
5502UG 008C1000 305 MT 5.443 KG GRAY 4 #22 PP FRPVC
5502UG 008C500 152 MT 2.722 KG GRAY 4 #22 PP FRPVC
5502UG 008U1000 305 MT 6.350 KG GRAY 4 #22 PP FRPVC
5502UG 008U500 152 MT 3.402 KG GRAY 4 #22 PP FRPVC
Page 2 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
5502UG Multi-Conductor - Residential, Light Commercial and Institutional Applications
5502UG 009C1000 305 MT 5.443 KG WHITE 4 #22 PP FRPVC
5502UG 009C500 152 MT 2.722 KG WHITE 4 #22 PP FRPVC
5502UG 009U1000 305 MT 6.350 KG WHITE 4 #22 PP FRPVC
Revision Number: 1 Revision Date: 03-18-2013
© 2013 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
5502UG Multi-Conductor - Residential, Light Commercial and Institutional Applications