Rated Rated Peak Max. Watt Fuse-link
current
voltage
arc interrupting I2t loss
voltage
(Amp
2
×sec.)
× 103Type
(A) (V) (W)
12 550V 1550 0.09 5.1 BLC012-1
20 AC 1550 0.27 8.5 BLC020-1
23 1550 0.39 10 BLC023-1
45 1380 1.8 19 BLC045-1
75 1250 5 32 BLC075-1
90 1250 11.5 38 BLC090-1
120 1200 33 51 BLC120-1
140 1200 100 59 BLC140-1
30 250V Max. 0.35 4.0 CR2L-30
50 AC 500 0.85 6.0 CR2L-50
75 2.3 9.0 CR2L-75
100 4.0 12.0 CR2L-100
125 6.5 14.0 CR2L-125
140 7.0 16.0 CR2L-140
150 9.5 18.0 CR2L-150
175 13 21.0 CR2L-175
200 17 23.0 CR2L-200
225 22 26.0 CR2L-225
260 27 30.0 CR2L-260
300 38 35.0 CR2L-300
325 49 37.0 CR2L-325
350 60 37.0 CR2L-350
400 103 39.0 CR2L-400
450 140 46.0 CR2L-450
500 160 48.0 CR2L-500
550 200 51.0 CR2L-550
600 215 56.0 CR2L-600
Interrupting capacity
BLC ...... 100kA at 550V AC
CR2L .... 100kA at 250V AC
BLC, CR and CS types
Super Rapid Fuses
1501500 Volts AC
104700 Amps
Description
The FUJI BLC, CR and CS types are
extremely reliable fuses which have
been specially developed to provide
protection for silicon diodes and
thyristors and are suitable for inverters
using semiconductors or transformers-
rectifiers. FUJI Super Rapid Fuses are
designed with a very small total I2t
value which gives them a high speed
interrupting action in the face of
abnormal currents.
In addition the arc voltage generated at
the time of interruption has a low value
so that faults will not influence related
electric machinery and equipment.
These fuses can carry out the
protection of many types of circuits
rating from the semiconductor
overcurrents to destructive short-
circuiting faults-i.e. when the
SD-36 SM-388 SI-431 SI-429
BLC CR2L CS5F CS10F
semiconductors short or circuits fail the
sound elements will be quickly isolated
from the fault circuits.
Features
The total clearing I2t is small and the
semiconductor circuit is completely
protected.
Since the peak arc voltage at the
time of interruption is low damage to
other equipment does not occur.
Low Voltage Fuses
BLC, CR and CS types
Super Rapid Fuses
Rated Rated Peak Max. Watt Fuse-link
current
voltage
arc interrupting I2t loss
voltage
(Amp
2
×sec.)
× 103Type
(A) (V) (W)
10 250V Max. 0.04 1.2 CR2LS-10
20 AC 500 0.17 3.0 CR2LS-20
30 0.35 4.0 CR2LS-30
50 0.85 6.0 CR2LS-50
75 2.3 9.0 CR2LS-75
100 4.0 12.0 CR2LS-100
20 600V Max. 0.14 4.0 CR6L-20
30 AC 1200 0.35 7.0 CR6L-30
50 1.8 9.0 CR6L-50
75 3.0 12.5 CR6L-75
100 7.0 15 CR6L-100
150 18 22.0 CR6L-150
200 30 34.0 CR6L-200
250 70 37.0 CR6L-250
300 95 40.0 CR6L-300
350 150 45.0 CR6L-350
400 200 55 CR6L-400
500 390 60 CR6L-500
600 700 70 CR6L-600
Interrupting capacity
CR2LS . 100kA at 250V AC
CR6L .... 100kA at 600V AC
High interrupting capacity of 200kA
at 1000V AC
The CS type is provided with a blown
fuse indicator. An alarm contact
block (1NO or 1NC) can also be
attached.
UL recognized: CR2L/UL,CR2LS/UL,
CR6L/UL
(File No. E92312)
CSA certificated: CR2LS/UL
(File No. LO4000-4090)
TÜV: CR2LS/UL (10-100A),
CR2L/UL (150-350A)
(Rep. No. E9450643E02)
CR6L/UL (50-300A)
(Rep. No. E9560543E02)
08/36
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
Specifications (UL-recognized, CSA certified, TÜV)
Rated Rated Inter- Max. Watt Fuse-link
current voltage rupting interrupting I
2
t loss
capacity (Amp
2
×sec.)
× 10
3
Type
(A) (kA) (W)
10 250V AC 10 at AC 0.04 1.2 CR2LS-10/UL
20 400V DC (pf: 0.8) 0.17 3.0 CR2LS-20/UL
30 10 at DC 0.35 4.0 CR2LS-30/UL
50 (L/R: 2ms) 0.85 6.0 CR2LS-50/UL
75 2.3 9.0 CR2LS-75/UL
100 4.0 12.0
CR2LS-100/UL
150 9.5 18.0 CR2L-150/UL
200 17 23.0 CR2L-200/UL
260 27 30.0 CR2L-260/UL
350 60 37.0 CR2L-350/UL
400 103 39.0 CR2L-400/UL
450 140 46.0 CR2L-450/UL
500 160 48.0 CR2L-500/UL
550 200 51.0 CR2L-550/UL
600 215 56.0 CR2L-600/UL
20 600V AC 100 at AC 0.14 4.0 CR6L-20/UL
680V DC (pf: 0.8)
30 10 at DC 0.35 7.0 CR6L-30/UL
(L/R: 2ms)
50 1.8 9.0 CR6L-50/UL
75 3.0 12.5 CR6L-75/UL
100 7.0 15.0 CR6L-100/UL
150 100 at AC 18 22.0 CR6L-150/UL
(pf: 0.8)
200 50 at DC 30 34.0 CR6L-200/UL
(L/R: 2ms)
300 95 40.0 CR6L-300/UL
Specifications
Rated Inter- Max. Watt Fuse-link
current rupting interrupting I2t loss
capacity
(Amp
2
×sec.)
× 103Type
(A) (kA) (W)
4700 150 at 14000 310 CS1F-4700
125V AC
2000 150 at 1950 124 CS2F-2000
3000 250V AC 5500 216 CS2F-3000
40 200 at 1 6.4 CS5F-40
75 500V AC 3.5 12 CS5F-75
100 5 17 CS5F-100
150 10 25 CS5F-150
200 18.5 34 CS5F-200
250 33 42 CS5F-250
300 64 45 CS5F-300
350 85 56 CS5F-350
400 122 57 CS5F-400
450 131 62 CS5F-450
500 159 73 CS5F-500
600 257 80 CS5F-600
800 600 114 CS5F-800
1000 1200 110 CS5F-1000
1000 843 167 CS5F-1000-P
1200 1800 114 CS5F-1200
1200 1311 200 CS5F-1200-P
1500 3600 209 CS5F-1500
1000 200 at 1800 125 CS8F-1000
1200 800V AC 2500 176 CS8F-1200
1500 4400 220 CS8F-1500
80 200 at 10 17 CS10F-80
100 1000V AC 16 21 CS10F-100
150 37 27 CS10F-150
200 63 37 CS10F-200
250 110 44 CS10F-250
300 148 53 CS10F-300
350 211 70 CS10F-350
400 307 74 CS10F-400
500 420 90 CS10F-500
560 410 102 CS10F-560
630 450 135 CS10F-630
750 640 156 CS10F-750
800 1259 211 CS10F-800-P
1000 1722 245 CS10F-1000-P
1250 2250 330 CS10F-1250-P
1500 3200 334 CS10F-1500-C
450 100 at 350 134 CS15F-450
630 1500V AC 760 170 CS15F-630
900 1400 280 CS15F-900-P
1250 3050 350 CS15F-1250-P
Note: Peak arc voltage
CS1F ..... Max. 450V
CS2F ..... Max. 750V
CS5F ..... Max. 1000V
CS8F ..... Max. 2000V
CS10F ... Max. 2000V
CS15F ... Less than 3000V
An alarm contact block AHX2905 (1NO) or AHX2915 (1NC) can be
attached to CS type. (Sold separately)
See page 08/44.
Low Voltage Fuses
BLC, CR and CS types
Super Rapid Fuses
Note: Peak arc voltage
CR2LS, CR2L .... Max. 500V
CR6L .................. Max. 1200V
The peak arc voltage is obtained by interruption caused by the listed
interrupting current at rated voltage.
This indcates the values when the conductors specified in UL
Standards are connected and rated current apply.
TÜV: CR2LS, 2L: Up to 350A
CR6L: 50 to 300A
Note: UL recognized fuse
In the UL recognized fuses, a fuse with a blown inidcation fuse, or a
fuse both with a blown indication fuse and a precision switch is also
UL recognized.
Examples: CR2L-200G/UL
CR2LS-30S/UL
CR6L-100G/UL
CR type fuse with optional accessory
Fuse with blown indication fuse
CR2L (S)- G
AF88-446
Fuse with blown indication fuse and precision switch
CR2L (S)- S Precision switch (SPDT)
CRX-1
AF88-445 AF88-442
precision switch
Fuji Electric FA components & Systems Co., Ltd./D & C Catalog
Information subject to change without notice
08/37
08
Dimensions, mm
BLC
BLC012, 020, 023 BLC045 BLC075 to 140
Type Rated A B øDød Color of Mass
current indicator (g)
(A)
BLC012-1 12 50 10 13 10 Grey 12
BLC020-1 20 50 10 13 14 Yellow 12
BLC023-1 23 50 10 13 14 Violet 12
BLC045-1 45 50 10 27 20 White 62
BLC075-1 75 63 6 34 5 Silver 120
BLC090-1 90 63 6 34 8 Red 120
BLC120-1 120 63 6 47 8 Yellow 120
BLC140-1 140 63 6 47 8 Light red 215
Note: The BLC type fuse link requires a holder in use. The size of the
holder differs according to the fuse ratings. Select the most suitable
one after referring to the Table on
page 08/44
.
For drawings see
page 08/32
.
CR2L-450 or smaller, CR2LS
Low Voltage Fuses
BLC, CR and CS types
Super Rapid Fuses
Dimensions for reference only. Confirm before construction begins.
Type A B C D E a×b F G H Mass
CR2L-30 80 58 18 21.5 37 9×11 90 1.5 26.5 42g
CR2L-50
CR2L-75 80 58 20 30.5 44 9×11 90 3 32.5 100g
CR2L-100
CR2L-125
CR2L-140
CR2L-150
CR2L-175
CR2L-200 85 60 25 33.5 47 11×13 93 3.2 33.5 130g
CR2L-225
CR2L-260
CR2L-300
CR2L-325
CR2L-350 95 70 30 42 54 11×13 98 4 39 220g
CR2L-400
CR2L-450
CR2LS-10 56 42 12 18.5 34.5 6.5×8.5 78 2 25 28g
CR2LS-20
CR2LS-30
CR2LS-50
CR2LS-75
CR2LS-100
Note: The dimensions of the fuses with suffix. UL are the same as those of the
standard ones.
Ordering information
Specify the following:
1. Type number
Type number nomenclature
BLC 012-1
Rated current: 12 to 140A
Plug-in type super rapid fuse
CS 10F-1000
-P/ UL
UL recognized (CR2L, CR2LS, CR6L)
CSA certificated (CR2LS)
TÜV (CR2LS, CR2L, CR6L)
2-fuse connected parallel
Optional accessory
(See page 08/44)
G: With blown indication fuse
S: With blown indication fuse
and precision switch
Rated current
10 to 4700A
Rated voltage
2L, 2LS: 250V AC, 6L: 600V AC
1F: 150V AC, 2F: 250V AC
5F: 500V AC, 8F: 800V AC
10F: 1000V AC, 15F: 1500V AC
CR: Barrel-shaped super rapid fuse
CS: Cubic-shaped super rapid fuse
Mass: 450g
CR2L-500 to -600
øD
B
ød
A
ød
B
A
øD
øD
A
ød
B
Blown indicatin
fuae (G type)
Mounting hole a × b
B
H
E
D
C
F
A
G
ø37
46.5
Blown indication
fuse (G type)
70
31
41.5
43
46
28
54
84
30
98
84
95
8
Mounting hole 11×13