SPECIFICATION
TS-1500-112 TS-1500-124 TS-1500-148 TS-1500-212 TS-1500-224 TS-1500-248
75A
21~30VDC
89%
37.5A
42~60VDC
90%
75A
21~30VDC
90%
37.5A
42~60VDC
91%
MODEL
ACVOLTAGE
MAXIMUMOUTPUTPOWER(Typ.)
WAVEFORM
OUTPUT FREQUENCY
ACREGULATION (Typ.)
VOLTAGERANGE (Typ.)Note.1
EFFICIENCY (Typ.) Note.2
DCCURRENT(Typ.) Note.5
INPUT
INPUT
BATTERY
OUTPUT
ENVIRONMENT
FUSE
SAFETY &
EMC
BAT.LOW ALARM
BAT.LOWSHUTDOWN
OVERTEMPERATURE
OUTPUTSHORT
REVERSEPOLARITY
GFCIPROCTECTION
PROTECTION
PROTECTION
Truesinewave(THD<3%)atratedinputvoltage
150A
10.5~15VDC
88%
40A*5 30A*3 30A*2
30A*230A*3
3.0%
10.5~15VDC
87%
150A
40A*5
82 5
Protectiontype:Shutdowno/pvoltage,re-powerontorecover;byinternalRTH3detectonheatsinkofpowertransistor
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
82 5 96 5
None
68 5 68 5 68 5
Byinternalfuseopen
UL458(onlyfor"GFCI"receptacle-TypeF) None
EMICONDUCTION&RADIATION
EMSIMMUNITY
CompliancetoFCCclass A
None
WORKINGTEMP. Note.3
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
SAFETY STANDARDS
0~+40 @100%load;60 @50%load
20%~90%RHnon-condensing
-30~+70 /-22~+158 F,10~95%RH
o
UL458(onlyfor"GFCI"receptacle-TypeF)
CompliancetoEN61000-4-2,3,8ENV50204
CompliancetoEN55022classB,72/245/CEE,95/54/CE,E-Mark
True sine wave output (THD<3%)
Power ON-OFF switch
Standby saving mode can be selectable
Front panel indicator for operation status
Thermostatically controlled cooling fan
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Input polarity reverse / Overload
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
Optional monitoring software
2 years warranty
High surge power up to 3000W
High efficiency up to 91%
RATEDPOWER (Typ.) 1500W
OVERLOAD(Typ.) 105~115%loadfor180sec.,115%~150%loadfor10sec.
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
WITHSTANDVOLTAGE BatI/P - ACO/P:3.0KVAC ACO/P -FG:1.5KVAC
VIBRATION 10~500Hz,3G10min./1cycle,60min.eachalongX, Y,Zaxes
E
13
Features :
OTHERS
PACKING 6.81Kg;2pcs/14.6Kg/1.61CUFT
DIMENSION 420*220*88mm(L*W*H)
NOTE 1.Output derating capacity referenced by curve 1.
2.Efficiency is tested by 1000W, linear load at 13V, 26V, 52V input voltage.
3.Output derating capacity referenced by curve 2.
4.All parameters not specified above are measured at rated load, 25 of ambient temperature.
5.DC current is tested by 1500W, linear load at 13V, 26V, 52V input voltage.
200/220/230/240VACselectablebysettingbutton
100/110/115/120VACselectableby settingbutton
1725Wfor180sec./2250Wfor10sec. /surgepower3000Wfor30cycles
11.3 4%22.5 4% 45 4%45 4%22.5 4%
10.5 4% 21 4% 42 4%42 4%21 4%
11.3 4%
10.5 4%
1500W TrueSineWaveDC-ACPowerInverter TS-1500 series
FileName:TS-1500-SPEC2009-02-07
50 0.1%Hz50/60HzselectablebysettingbuttonS.W
60 0.1Hz50/60HzselectablebysettingbuttonS.W
FRONTPANEL INDICATOR
SAVINGMODE(Typ.) Load 5Wwillbechangedtostandbymode
Batteryvoltagelevel,outputloadlevel,savingmode,faultandoperationstatus
24V 48V 24V 48V
BAT.VOLTAGE 12V12V
NOLOADDISSIPATION 18W @ standby saving mode
OFFMODE DRAWCURRENT 1mA
BATTERY TYPES Open&sealedLead Acid
CONTROL WIRING RJ11-RS232(Option)
LVD None EN60950-1