DW Series Digital Panel Meters Backlighting Options * Non-Backlit LCD Black on Grey Background Get Digital Accuracy with an Analog Footprint The DW Series is a cost-effective solution to retrofitting an analog panel cutout with a digital meter. * The DW is easy-reading with large display and wider viewing angles * No additional wires makes installation faster and easier * Automatic polarity indication * Custom nomenclature optional The MODUTEC DW Series is available as DC and AC Power Monitors and Process Monitors. Please refer to the DW Spec sheet found on our Web site www.jewellinstruments.com for specification and part numbers. Specifications Display Applications Digits: Type: Digit Height: Polarity: Decimal Point: Overload: 3 1/2 ( 1999) 7 segment reflective LCD 0.5" (12.7mm) Automatic (-) displayed Factory set. Provisions for selection by user optional Three lower digits blank for readings greater than 1999 counts Telecommunications Water Purification Input Resistance: Sewage Treatment Flow Process Desalinization AC & DC Amps AC & DC Volts Input Voltage Drop (current Meters): Overvoltage (voltmeters): Accuracy: Tempco: Conversion Rate: Normal Mode Rejection: Common Mode Rejection: Common Mode Voltage Range: Operating Range: Storage Temperature: DC Inputs 200mV & 2V ranges >100megohm, 20V & 200V ranges 1 megohm 200mV typical at fs 300 VDC 0.1% 2 digits 100 ppm/C typical 2.5 per second 60db typical >86db 1V maximum 32F to 122F (0C to +50C) -4F to 158F (-20C to + 70C) sales@jewellinstruments.com * www.jewellinstruments.com * 800 638-3771 DW Series ( mm/in ) Panel Cutout for DW Series Surface Mount V T Panel Cutout for DW Series WindoTM Mount V Z V +25 *00 +.010*00 Y AC Amps 300:5A User Provided V A in 3.5" Transformer Supplied With Meter .25 R Max. .010 DW Series Dimensional Drawings W 2.5" Connection for High Current Measurement B C D E F G H J K L M N P R S T V W X Y C B G Z mm 29.1 76.5 40.5 33.0 53.8 38.1 28.5 24.1 36.8 32.0 1.5 12.7 12.7 3.7 M-3.5 M-5 3.2 23.9 56.4 M-3 32.3 73.7 in. 1.145 3.01 1.6 1.30 2.12 1.50 1.12 .95 1.45 1.26 .06 .50 .50 .145 6-32 10-32 1.25 .94 2.22 4-40 1.27 2.9 A X R - Power + K S mm 36.8 94.7 41.1 33.0 67.6 38.1 28.5 36.8 49.5 40.3 1.8 12.7 12.7 3.7 M-3.5 M-5 3.2 28.4 71.6 M-3 40.5 91.7 in 1.45 3.73 1.62 1.30 2.66 1.50 1.12 1.45 1.95 1.585 .07 .50 .50 .145 6-32 10-32 .125 1.12 2.82 4-40 1.595 3.61 J Input + A L D H F M E N P DW Series Specifications Range DC Microammeters 0-200 2.5" Meter Part Number 3.5" Meter Part Number * 3DW-DUA-200- * * * 3DW-DMA-0023DW-DMA-0203DW-DMA-200- 2DW-DUA-200- * DC Milliammeters 0-2 0-20 0-200 2DW-DMA-0022DW-DMA-0202DW-DMA-200- * * * DC Milliammeters -- 2 wire, self-powered 4-201 L2DW-DMA-020 4-202 P2DW-DMA-020 1 Requires 1.5 VDC Loop-drop 2 Requires 2.75 VDC Loop-drop L3DW-DMA-020 P3DW-DMA-020 To Order: Select range and size from listing above. Complete the catalog number by replacing with the power options suffix from below. * Power Option 3 4 Description Suffix 115VAC 115VAC 10%, 50 or 60 Hz P115 230VAC 230VAC 10%, 50 or 60 Hz 5VDC + 5VDC 5% at 3mA, typical 10-28VDC (auto & marine) + 10 to +28VDC at 5mA, typical P10-28 Battery 9VDC nom., 7.2 to 12 VDC at 150A, typical4 P9 P230 P5 3 3 Meters must have low input connected to DC supply return Meters must have input isolated from battery Specifications and ordering information for DC & AC power monitors and Process Monitors can be found on our website. sales@jewellinstruments.com * www.jewellinstruments.com * 800 638-3771 850 Perimeter Road * Manchester, NH 03103 * USA DW Series Specifications (continued) DC Power Monitors Range: 10VDC to 28VDC Resolution: 0.1VDC Accuracy: (0.1% + 2 counts) with shunt amp Display: 0.5" high digits LCD Power Requirements: 10VDC to 28VDC @ 20MA Operating Temperature: 32F to 122F (0C to 50C) Storage Temperature: -4F to 149F (-20C to 65C) Circuit boards are conformal coated for protection Volt Meters: Marine battery meters Size 2 1/2" 3 1/2" Part Number P2DW-DVV-10/28 P3DW-DVV-10/28 Amp Meters Size 2 1/2" 2 1/2" 2 1/2" 2 1/2" 2 1/2" 3 1/2" 3 1/2" 3 1/2" 3 1/2" 3 1/2" Range Shunt Part Number 0-50.0A 0-500A 0-10.00A 0-100.0A 0-1000A 0-50.0A 0-500A 0-10.00A 0-100.0A 0-1000A 50mV 50mV 100mV 100mV 100mV 50mV 50mV 100mV 100mV 100mV 2DWS-DAA-050-P10-28 2DWS-DAA-500-P10-28 2DWS-DAA-010-P10-28 2DWS-DAA-100-P10-28 2DWS-DAA-1000-P10-28 2DWS-DAA-050-P10-28 2DWS-DAA-500-P10-28 2DWS-DAA-010-P10-28 2DWS-DAA-100-P10-28 2DWS-DAA-1000-P10-28 AC Power Monitors Range: 80-130VAC, 160-260VAC Resolution: 1V Accuracy: (0.5% + 1 count) Display: 0.5" high digits LCD Power Requirements: 2VA Typical Operating Temperature: 32F to 122F (0C to 50C) Storage Temperature: -4F to 149F (-20C to 65C) Circuit boards are conformal coated for protection Volt Meters Size 2 1/2" 3 1/2" 2 1/2" 3 1/2" Range Part Number 80-130VAC 80-130VAC 160-260VAC 160-260VAC P2DW-AVV-80/130 P3DW-AVV-80/130 P2DW-AVV-160/260 P3DW-AVV-160/260 sales@jewellinstruments.com * www.jewellinstruments.com * 800 638-3771 850 Perimeter Road * Manchester, NH 03103 * USA DW Series Specifications (continued) Range: 0-50 AMP AC1 Resolution: 0.1 AMP Accuracy: (0.5% + 5 counts) Display: 0.5" high digits LCD Power Requirements: 2VA Typical Operating Temperature: 32F to 122F (0C to 50C) Storage Temperature: -4F to 149F (-20C to 65C) Circuit boards are conformal coated for protection Calibrated with external transformer that is shipped with meter. Amp Meters Size 2 1/2" 3 1/2" 2 1/2" 3 1/2" Power Part Number 115VAC 115VAC 230VAC 230VAC 2DW-AAAX-050-P115 3DW-AAAX-050-P115 2DW-AAAX-050-P230 3DW-AAAX-050-P230 Process Monitors Type DC Milliammeters (Loop Receiver, 4-wire) DC Millivoltmeters DC Voltmeters Range 2 1/2" Meters Part Number 4-20 10-50 0-200 0-2 0-20 0-200 N2DW-DMA-020N2DW-DMA-0502DW-DMV-2002DW-DVV-0022DW-DVV-0202DW-DVV-200- * * * * * * 3 1/2" Meters Part Number * * * * * * N3DW-DMA-020N3DW-DMA-0503DW-DMV-2003DW-DVV-0023DW-DVV-0203DW-DVV-200- To Order: Select range and size from listing above. Complete the catalog number by replacing with the power options suffix from below. * Power Options: Option Description 115VAC 230VAC 5VDC 1-28VDC (auto & marine) Battery 115VAC 10%, 50 or 60 Hz 230VAC 10%, 50 or 60 Hz + 5VDC 5% at 3mA, typical2 + 10 to +28VDC at 5mA, typical2 9VDC nom., 7.2 to 12 VDC at 150A, typical3 *P115Suffix P230 P5 P10-28 P9 1 For higher currents, a 0-5 Amp AC input version is available for use with a user supplied current transformer. The value of full-scale current displayed for the 5 Amp input needs to be specified. e.g.: 2DW-AAAX-300-P115 would be a 2 1/2", 115VAC powered meter for use with a customer supplied 300 to 5 Amp current transformer. 2 Meters must have low input connected to DC supply return 3 Meters must have input isolated from battery sales@jewellinstruments.com * www.jewellinstruments.com * 800 638-3771 850 Perimeter Road * Manchester, NH 03103 * USA