1514
Doc #97023 DATA DELAY DEVICES, INC. 1
2/5/97 3 Mt. Prospect Ave. Clifton, NJ 07013
FIXED SIP DELAY LINE
TD/TR = 5
(SERIES 1514)
FEATURES PACKAGES
Fast rise time for high frequency applications
Very narrow device (SIP package)
Stackable for PC board economy
Low profile
Epoxy encapsulated
Meets or exceeds MIL-D-23859C
FUNCTIONAL DESCRIPTION
The 1514-series device is a fixed, single-input, single-output, passive
delay line. The signal input (IN) is reproduced at the output (OUT), shifted
by a time (TD) given by the device dash number. The characteristic
impedance of the line is given by the letter code that follows the dash
number (See Table). The rise time (TR) of the line is 20% of TD, and the 3dB bandwidth is given by 1.75 /
TD.
SERIES SPECIFICATIONS
Dielectric breakdown: 50 Vdc
Distortion @ output: 10% max.
Operating temperature: -55°C to +125°C
Storage temperature: -55°C to +125°C
Temperature coefficient: 100 PPM/°C
DASH NUMBER SPECIFICATIONS
Part
Number Delay (ns) Rise Time
(ns) Impedance
()
1514-2.5A 2.5 ± 1.0 1.0 50
1514-5A 5.0 ± 1.0 1.0 50
1514-10A 10.0 ± 1.0 2.0 50
1514-15A 15.0 ± 1.0 3.0 50
1514-20A 20.0 ± 1.0 4.0 50
1514-25A 25.0 ± 1.3 5.0 50
1514-30A 30.0 ± 1.5 6.0 50
1514-40A 40.0 ± 2.0 8.0 50
1514-50A 50.0 ± 2.5 10.0 50
1514-60A 60.0 ± 3.0 12.0 50
1514-80A 80.0 ± 4.0 16.0 50
1514-100A 100 ± 5.0 20.0 50
1514-3.5Y 3.5 ± 1.0 1.0 75
1514-7.5Y 7.5 ± 1.0 1.5 75
1514-15Y 15.0 ± 1.0 3.0 75
1514-22.5Y 22.5 ± 1.2 4.5 75
1514-30Y 30.0 ± 1.5 6.0 75
1514-37.5Y 37.5 ± 1.9 7.5 75
1514-45Y 45.0 ± 2.3 9.0 75
1514-60Y 60.0 ± 3.0 12.0 75
1514-75Y 75.0 ± 3.8 15.0 75
1514-90Y 90.0 ± 4.5 18.0 75
1514-105Y 105 ± 5.3 21.0 75
1514-120Y 120 ± 6.0 24.0 75
1514-135Y 135 ± 6.8 27.0 75
1514-150Y 150 ± 7.5 30.0 75
1997 Data Delay Devices
data
delay
devices, inc.
3
2
6
7
1
GNDIN OUTGND
1514-xxz
xx = Delay (TD)
z= Impedance Code
PIN DESCRIPTIONS
IN Signal Input
OUT Signal Output
GND Ground
Functional Diagram
GND
IN
GND
OUT
DASH NUMBER SPECIFICATIONS
Part
Number Delay (ns) Rise Time
(ns) Impedance
()
1514-5B 5.0 ± 1.0 1.0 100
1514-10B 10.0 ± 1.0 2.0 100
1514-20B 20.0 ± 1.0 4.0 100
1514-30B 30.0 ± 1.5 6.0 100
1514-40B 40.0 ± 2.0 8.0 100
1514-50B 50.0 ± 2.5 10.0 100
1514-60B 60.0 ± 3.0 12.0 100
1514-80B 80.0 ± 4.0 16.0 100
1514-100B 100 ± 5.0 20.0 100
1514-120B 120 ± 6.0 24.0 100
1514-140B 140 ± 7.0 28.0 100
1514-150B 150 ± 7.5 30.0 100
1514-50D 50.0 ± 2.5 10.0 250
1514-70D 70.0 ± 3.5 14.0 250
1514-120D 120 ± 6.0 24.0 250
1514-130D 130 ± 6.5 26.0 250
1514-150D 150 ± 7.5 30.0 250
1514-170D 170 ± 8.5 34.0 250
1514-270D 270 ± 13.5 54.0 250
1514-70E 70.0 ± 3.5 14.0 300
1514-140E 140 ± 7.0 28.0 300
1514-45G 45.0 ± 2.3 9.0 500
1514-50G 50.0 ± 2.5 10.0 500
1514-80G 80.0 ± 4.0 16.0 500
1514-100G 100 ± 5.0 20.0 500
1514-190G 190 ± 9.5 38.0 500
1514
Doc #97023 DATA DELAY DEVICES, INC. 2
2/5/97 Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com
.280
MAX.
.100
MIN.
.810 MAX.
1 2 6 7
.210
MAX.
.020
TYP.
.020 TYP.
.600 TYP.
.100
TYP. .010
TYP.
Package Dimensions
PASSIVE DELAY LINE TEST SPECIFICATIONS
TEST CONDITIONS
INPUT: OUTPUT:
Ambient Temperature: 25oC ± 3oCRload:10M
Input Pulse: High = 3.0V typical Cload:10pf
Low = 0.0V typical Threshold: 50% (Rising & Falling)
Source Impedance: 50 Max.
Rise/Fall Time: 3.0 ns Max. (measured
at 10% and 90% levels)
Pulse Width (TD <= 75ns): PWIN = 100ns
Period (TD <= 75ns): PERIN = 1000ns
Pulse Width (TD > 75ns): PWIN = 2 x TD
Period (TD > 75ns): PERIN = 10 x TD
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.
Timing Diagram For Testing
TRISE TFALL
PERIN
PWIN
TRISE TFALL
10%
10%
50%
50%
90%
90%
50%
50%
VIH VIL
VOH VOL
INPUT
SIGNAL
OUTPUT
SIGNAL
TRISE TFALL
10%
10%
90%
90%
OUT
OUT
TRIG
TRIG
Test Setup
DEVICE UNDER
TEST (DUT)
OSCILLOSCOPE
PULSE
GENERATOR
50 ROUT
RIN
RIN = ROUT = ZLINE