PIN FUNCTIONS
N. Name Description
1 POWER OUTPUT The device is provided with short circuit protection.
4 POWER SUPPLY Supply voltage input.
5 ENABLE INPUT TTL compatible input. High level on this pin means output current ON.
The low level voltage switches off the charge pump, the power stage and
the diagnostic output reducing to the minimum value the quiescent current.
7 GROUND This pin must be connected to ground.
8 DIAGNOSTIC FEEDBACK The diagnostic circuit is active in input high level condition. This output
detects with Tipically 50µs delay at Tamb = 25°C the following faults:
– Overvoltage condition.
– Thermal shutdown.
– Short circuit. The power stage current is internally limited at 1.5A.
The diagnostic output is active low. The diagnostic delay time allows to
avoid spurious diagnosys(i.e.: turn ON overcurrent, overvoltage spikes etc.).
ELECTRICA L CHARACTERI STICS (V S = 14.4V, –40°C≤ Tj ≤ +85°C, unless otherwise spec ified.)
Symbol Parameter Test Condition Min. Typ. Max. Unit
VSOperating Supply Voltage 6 25 V
Ron On Resistance Input > 2V, Tj = 25°C
Input > 2V, Full T range 0.6 0.8
1.2 Ω
Ω
Ioff Off State Supply Current Tj < 35°C
Tj = 85°C130
300 µA
µA
Ion On State Supply Current 4 mA
VEL Enable Low Level 0.8 V
VEH Enable High Level 2 V
IEEnable Current 0V < Vi <5V 10 µA
Ileakd Diagnostic Output Leakage Current VCC = 5V Diagnostic Output High 10 µA
Vsatd Diagnostic Output Saturated
Voltage Isink < 3.5mA 0.4 V
tdd Diagnostic Delay Time Tj = 25°C30µs
t
don Output ON Delay Time Tj = 25°C30µs
t
r
Output ON Rise Time Tj = 25°C 100 µs
tdoff Output OFF Delay Time Tj = 25°C80µs
t
f
Output OFF Fall Time Tj = 25°C 100 µs
Vdon Overvoltage Detection ON 25 V
Vdh Overvoltage Hysteresis 2 5 V
Idon Overcurrent Detection ON 0.5 1.5 A
Tdon Overtemperature Detection ON 150 °C
Tdh Overtemperature Hysteresis 25 50 °C
L9820