3 Volt Voltage Variable Absorptive Attenuator
40 dB, 0.5 - 2.0 GHz
Rev. V1
MAAV-008022
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
* Restrictions on Hazardous Substances, European Directive 2002/95/EC.
Functional Schematic 2,3,4,5
Ordering Information 1
1. Reference Application Note M513 for reel size information.
Part Number Package
MAAV-008022-000000 Bulk Packaging
MAAV-008022-TR3000 3000 piece reel
Features
Single Positive Voltage Control: 0 to +3 Volts
40 dB Attenuation Range at 0.9 GHz
± 2 dB Linearity from BSL
Low DC Power Consumption
Lead-Free SOIC-8 Plastic Package
100% Matte Tin Plating over Copper
Halogen-Free “Green” Mold Compound
260°C Reflow Compatible
RoHS* Compliant Version of AT-113
Description
M/A-COM’s MAAV-008022 is a GaAs MMIC voltage
variable absorptive attenuator in a lead-free low-cost
SOIC 8-lead surface mount plastic package. The
MAAV-008022 is ideally suited for use where linear
attenuation fine tuning and very low power
consumption are required.
Typical applications include radio, cellular, GPS
equipment and automatic gain/level control circuits.
The MAAV-008022 is fabricated with a monolithic
GaAs MMIC using a mature 1-micron process. The
process features full chip passivation for increased
performance and reliability.
7 6 58
1 2 3 4
2. VCC = +3 VDC @ 50 µA maximum.
3. VC = 0 VDC to +3 VDC @ 50 µA maximum.
4. External DC blocking capacitors are required on all RF ports.
5. 39 pF used for data measurements.
Pin Configuration
Pin No. Function Pin No. Function
1 Ground 5 VC
2 Ground 6 Ground
3 RF Port 7 RF Port
4 VCC 8 Ground
Absolute Maximum Ratings 6
Parameter Absolute Maximum
Input Power +21 dBm
Supply Voltage VCC -1 V < VCC < +8 V
Control Voltage VC -1 V < VC < VCC + 0.5 V
Operating Temperature -40°C to +85°C
Storage Temperature -65°C to +150°C
6. Exceeding any one or combination of these limits may cause
permanent damage to this device.
2
3 Volt Voltage Variable Absorptive Attenuator
40 dB, 0.5 - 2.0 GHz
Rev. V1
MAAV-008022
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
Lead-Free SOIC-8
Electrical Specifications 7: TA = 25°C, Z0 = 50
Parameter Test Conditions Units Min Typ Max
Insertion Loss 0.5 - 1.0 GHz
1.0 - 2.0 GHz
dB
dB
2.7
3.0
3.0
3.5
Attenuation
(Relative to Insertion Loss)
Frequency = 0.5 - 2.0 GHz
Vc = 0.0 V (max. atten.)
Vc = 0.5 V
Vc = 1.5 V
Vc = 2.7 V
dB
dB
dB
dB
34
26
12.5
35
30
15
.5
17.5
0.7
Slope
(at any point on the curve)
Vc delta 0.5 V - 1.5 V
Vc delta 1.5 V - 2.7 V
dB/V
dB/V
10
0
15
14
23
17
VSWR Ratio 2:1
Trise, Tfall 10% to 90% RF, 90% to 10% RF µS 10
Ton, Toff 50% Control to 90% RF, 50% Control to 10% RF µS 12
Transients In-band mV 10
7. The RF ports must be blocked outside of the package from ground or any other voltage.
Reference Application Note M538 for lead-free solder reflow recommendations.
Meets JEDEC moisture sensitivity level 1 requirements.
3
3 Volt Voltage Variable Absorptive Attenuator
40 dB, 0.5 - 2.0 GHz
Rev. V1
MAAV-008022
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
Typical Performance Curves @ 25°C
Attenuation vs. Control Voltage
Insertion Loss vs. Frequency Return Loss vs. Control Voltage, F = 900 MHz
Attenuation vs. Frequency @ 0V
IP3 vs. Control Voltage
1 dB Compression vs. Control Voltage
-3.5
-3.0
-2.5
-2.0
-1.5
-1.0
-0.5
0.0
0.5 1.0 1.5 2.0 2.5 3.0
Frequency (GHz)
-50
-40
-30
-20
-10
0
0.00.51.01.52.02.53.0
0.9 GHz
1.8 GHz
2.4 GHz
Control Voltage (V)
-50
-40
-30
-20
-10
0
0.5 1.0 1.5 2.0 2.5 3.0
Frequency (GHz)
-30
-25
-20
-15
-10
-5
0
0.00.51.01.52.02.53.0
S11
S22
Control Voltage (V)
-5
0
5
10
15
20
25
0.00.51.01.52.02.53.0
400 MHz
900 MHz
Control Voltage (V)
0
5
10
15
20
25
30
35
0.00.51.01.52.02.53.0
400 MHz
900 MHz
Control Voltage (V)
4
3 Volt Voltage Variable Absorptive Attenuator
40 dB, 0.5 - 2.0 GHz
Rev. V1
MAAV-008022
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
Attenuation vs. Temperature
Normalized @ 25°C, F = 900 MHz
-3
-2
-1
0
1
2
3
0.00.501.01.52.02.53.0
+85°C
-40°C
Control Voltage (V)
Typical Performance Curves @ 25°C
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
5
3 Volt Voltage Variable Absorptive Attenuator
40 dB, 0.5 - 2.0 GHz
Rev. V1
MAAV-008022
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
M/A-COM Technology Solutions Inc. All rights reserved.
Information in this document is provided in connection with M/A-COM Technology Solutions Inc ("MACOM")
products. These materials are provided by MACOM as a service to its customers and may be used for
informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or
in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM
assumes no responsibility for errors or omissions in these materials. MACOM may make changes to
specifications and product descriptions at any time, without notice. MACOM makes no commitment to update
the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future
changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise,
to any intellectual property rights is granted by this document.
THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR
INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR
OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY
OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN
THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS,
WHICH MAY RESULT FROM THE USE OF THESE MATERIALS.
MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM
customers using or selling MACOM products for use in such applications do so at their own risk and agree to