Product: 1212
Category 5E+ Cable, 4 Pair, U/UTP, CMR
Product Description
Category 5E+ Premise Horizontal Cable (350MHz), 4 Pair, 24 AWG Solid Bare Copper Conductors, U/UTP, Riser-CMR, PVC Jacket
Technical Specifications
Product Overview
Suitable Applications: Premise Horizontal Cable, Ethernet 1000BASE-T, Ethernet 100BASE-TX, Ethernet 10BASE-T, PoE++, PoE+, PoE
Patent: This product has one or more applicable patents. More information on patents can be found at https://www.belden.com/resources/patents.
Construction Details
Conductor
AWG Stranding Material Number of Pairs
24 Solid BC - Bare Copper 4
Insulation
Material Color Code
PO - Polyolefin White/Blue Stripe & Blue, White/Orange Stripe & Orange, White/Green Stripe & Green, White/Brown Stripe & Brown
Bonded-Pair: No
Outer Jacket Material
Material Nom. Diameter Ripcord
PVC - Polyvinyl Chloride 0.206 in Yes
Electrical Characteristics
Electricals
Max. Conductor DCR Max. DCR Unbalance Max. Capacitance Unbalance Nom. Mutual Capacitance
89 Ohm/km 3% 330 pF/100m 15 pF/ft
Delay
Frequency [MHz] Max. Delay Max. Delay Skew Nom. Velocity of Propagation (VP) [%]
100 MHz 537.6 ns/100m 25 ns/100m 70%
High Freq
Frequency
[MHz]
Max. Insertion Loss
(Attenuation)
Min.
NEXT [dB]
Min.
PSNEXT [dB]
Min.
ACR [dB]
Min.
PSACR [dB]
Min. ACRF
(ELFEXT) [dB]
Min. PSACRF
(PSELFEXT) [dB]
Min. RL (Return
Loss) [dB]
Max./Min. Input
Impedance (unFitted)
Max./Min. Fitted
Impedance
1 MHz 2.0 dB/100m 70.3 dB 69.3 dB 68.3 dB 67.3 dB 67.8 dB 65.8 dB 20.0 dB 100 ± 15 Ohm 100 ± 15 Ohm
4 MHz 4.0 dB/100m 61.3 dB 60.3 dB 57.3 dB 56.3 dB 55.8 dB 53.8 dB 23.0 dB 100 ± 15 Ohm 100 ± 15 Ohm
8 MHz 5.7 dB/100m 56.8 dB 55.8 dB 51.1 dB 50.1 dB 49.7 dB 47.7 dB 24.5 dB 100 ± 15 Ohm 100 ± 15 Ohm
10 MHz 6.4 dB/100m 55.3 dB 54.3 dB 48.9 dB 47.9 dB 47.8 dB 45.8 dB 25.0 dB 100 ± 15 Ohm 100 ± 15 Ohm
16 MHz 8.1 dB/100m 52.2 dB 51.2 dB 44.1 dB 43.1 dB 43.7 dB 41.7 dB 25.0 dB 100 ± 15 Ohm 100 ± 15 Ohm
20 MHz 9.1 dB/100m 50.8 dB 49.8 dB 41.7 dB 40.7 dB 41.8 dB 39.8 dB 25.0 dB 100 ± 15 Ohm 100 ± 15 Ohm
25 MHz 10.2 dB/100m 49.3 dB 48.3 dB 39.1 dB 38.1 dB 39.8 dB 37.8 dB 24.3 dB 100 ± 15 Ohm 100 ± 15 Ohm
31.25 MHz 11.4 dB/100m 47.9 dB 46.9 dB 36.4 dB 35.4 dB 37.9 dB 35.9 dB 23.6 dB 100 ± 15 Ohm 100 ± 15 Ohm
62.5 MHz 16.4 dB/100m 43.4 dB 42.4 dB 27.0 dB 26.0 dB 31.9 dB 29.9 dB 21.5 dB 100 ± 15 Ohm 100 ± 15 Ohm
100 MHz 21.0 dB/100m 40.3 dB 39.3 dB 19.3 dB 18.3 dB 27.8 dB 25.8 dB 20.1 dB 100 ± 15 Ohm 100 ± 15 Ohm
155 MHz 26.6 dB/100m 37.4 dB 36.4 dB 10.9 dB 9.9 dB 24.0 dB 22.0 dB 18.8 dB 100 ± 22 Ohm 100 ± 15 Ohm
200 MHz 30.5 dB/100m 35.8 dB 34.8 dB 5.3 dB 4.3 dB 21.8 dB 19.8 dB 18.0 dB 100 ± 22 Ohm 100 ± 15 Ohm
250 MHz 34.4 dB/100m 34.3 dB 33.3 dB -0.1 dB -1.1 dB 19.8 dB 17.8 dB 17.3 dB 100 ± 32 Ohm 100 ± 15 Ohm
300 MHz 38.0 dB/100m 33.1 dB 32.1 dB 18.3 dB 16.3 dB 14.4 dB 100 ± 32 Ohm 100 ± 15 Ohm
350 MHz 41.4 dB/100m 32.1 dB 31.1 dB 16.9 dB 14.9 dB 13.8 dB 100 ± 32 Ohm 100 ± 15 Ohm
400 MHz 44.6 dB/100m 31.3 dB 30.3 dB 15.8 dB 13.8 dB 13.3 dB 100 ± 32 Ohm 100 ± 15 Ohm
450 MHz 47.7 dB/100m 30.5 dB 29.5 dB 14.7 dB 12.7 dB 12.8 dB 100 ± 32 Ohm 100 ± 15 Ohm
Voltage
UL Voltage Rating
300 V (CMR)
Mechanical Characteristics
Temperature
UL Rating. Operating Installation Storage
75°C -20°C To +75°C 0°C To +50°C -20°C To +75°C
Bend Radius
Stationary Min. Installation Min.
1.0 in 2.25 in
Max. Pull Tension: 25 lbs
Bulk Cable Weight: 20 lbs/1000ft
Standards and Compliance
Environmental Suitability: Riser, Indoor
Sustainability: Product Lens™, Environmental Product Declaration (EPD) Available
Flammability / Fire
Resistance: UL 1666 Riser, FT4, FT4, IEC 60332-1-2
NEC / UL Compliance: Article 800, CMR
CEC / C(UL)
Compliance: CMR
ICEA Compliance: S-90-661-2012
IEEE Compliance: IEEE 802.3bt Type 1, Type 2, Type 3
NEMA Compliance: NEMA WC-63.1
Data Category: Category 5e
TIA/EIA Compliance: ANSI/TIA-568.2-D Category 5e
CPR Euroclass: Eca
European Directive
Compliance: EU CE Mark, EU Directive 2015/863/EU, EU Directive 2011/65/EU (ROHS II), EU Directive 2012/19/EU (WEEE), REACH: 2020-01-16
APAC Compliance: China RoHS II (GB/T 26572-2011)
Part Number
Plenum Number: 1213
Variants
Item # Color UPC
1212 010U1000 Black 612825061410
1212 0061000 Blue 612825061519
1212 0062500 Blue 612825061434
1212 006U1000 Blue 612825061427
1212 008U1000 Gray 612825061465
1212 005U1000 Green 612825061441
1212 003U1000 Orange 612825061458
1212 0091000 White 612825061489
1212 009U1000 White 612825061472
1212 0041000 Yellow 612825062189
1212 004U1000 Yellow 612825061496
Product Notes
Notes: Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Values above 350 MHz are for Engineering
Information Only. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0.
History
Update and Revision: Revision Number: 0.321 Revision Date: 09-30-2020
© 2021 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without
notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and